©OMRON Corporation 2008 All Rights Reserved. 1 SYSMAC Gateway Runtime Version1.00 SYSMAC Gateway Runtime Installation Guide 1. Introduction Thank you for purchasing the SYSMAC Gateway Runtime Edition. This guide gives a description of SYSMAC Gateway Runtime installation. Read this guide thoroughly to understand the instruction before using the product. 1.1. Components This package includes the following components. Please confirm that all the components are included in the package. (This installation document is not included.) z Product Guide z Installation Disc (CD-ROM) z Software License Agreement z User Registration Card (Japanese) z User Registration Card (English) z Mailing Label 1.2. Conditions of Use Read the Conditions of Use (separate document) thoroughly to confirm agreement before using the product. 2. Overviews 2.1. Functional over view “SYSMAC Gateway Runtime“ is the communication middleware product which provides the FA network environments on personal computers. “SYSMAC Gateway Runtime” includes “FinsGateway Middleware” which supports OMRON communication Protocol “FINS” as in the past and SYSMAC Gateway Middleware which supports “EtherNet/IP” building industrial multivendor network environment. SYSMAC Gateway Middleware supports “Tag Datalink” (cyclic communication) function by Ethernet/IP. In the past, to support “Datalink” function we need to have the special network card, like “Controller Link”. With SYSMAC Gateway and EtherNet/IP you can use the “Datalink” function on the de-facto standard, Ethernet. PLC memory data is appeared on the shared memory, called “Event Memory”, on the computer, which is same function as “Controller Link” provide. You can use this data just like the shared

SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

Embed Size (px)

Citation preview

Page 1: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

1SYSMAC Gateway Runtime Version1.00

SYSMAC Gateway Runtime Installation Guide

1. Introduction Thank you for purchasing the SYSMAC Gateway Runtime Edition.

This guide gives a description of SYSMAC Gateway Runtime installation. Read this guide thoroughly to understand the instruction before using the product.

1.1. Components

This package includes the following components. Please confirm that all the components are included in the package. (This installation document is not included.)

Product Guide Installation Disc (CD-ROM) Software License Agreement User Registration Card (Japanese) User Registration Card (English) Mailing Label

1.2. Conditions of Use

Read the Conditions of Use (separate document) thoroughly to confirm agreement before using the product.

2. Overviews

2.1. Functional over view

“SYSMAC Gateway Runtime“ is the communication middleware product which provides the FA network environments on personal computers. “SYSMAC Gateway Runtime” includes “FinsGateway Middleware” which supports OMRON communication Protocol “FINS” as in the past and SYSMAC Gateway Middleware which supports “EtherNet/IP” building industrial multivendor network environment.

SYSMAC Gateway Middleware supports “Tag Datalink” (cyclic communication) function by Ethernet/IP.

In the past, to support “Datalink” function we need to have the special network card, like “Controller Link”. With SYSMAC Gateway and EtherNet/IP you can use the “Datalink” function on the de-facto standard, Ethernet. PLC memory data is appeared on the shared memory, called “Event Memory”, on the computer, which is same function as “Controller Link” provide. You can use this data just like the shared

Page 2: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

2 SYSMAC Gateway Runtime Version1.00

memory data from your application.

The way to access value of “Event memory” is compatible with FinsGateway as in the past.

Furthermore, by using CX-Compolet it is possible to do tag name based programming without regard for address.

FinsGateway Middleware provides FA network environment to communicate transparently without regard for number of networks which OMRON provides. With FinsGateway you can use FINS message communication function and shared memory function, called “Event memory”, to share the data with PLC and other devices.

2.2. Precautions

・ When you configure “Tag Datalink” you need to use “Network Configurator”, which belong to OMRON support software, “CX-One”. You must install “CX-One” first before installing “SYSMAC Gateway”.

・ This installer is for installing “SYSMAC Gateway runtime environment” only. With this environment you can run SYSMAC Gateway based application. To develop SYSMAC Gateway application you need to have “CX-Compolet” or “SYSMAC Gateway SDK” separately.

・ When configuring the Tag datalink in EtherNet/IP Network, Version V3.01 or higher of Network Configurator included in CX-One V3 is required.When installing the Network Configurator by CX-One V3.0x, please perform the CX-One AutoUpdate.

・ Though structured variables and array variables are applicable to the SYSMAC Gateway, It's not possible to create the tag data link connection with other EtherNet/IP node specifying the member of structured variable or element of array variable to the tag.

・ Windows vista doesn’t allow building sample programs which belong to the “Program Files”. Please move the sample programs to a user folder when you rebuild.

3. Operating Environment SYSMAC Gateway operates in environments where the hardware and software

supported by SYSMAC Gateway can run effectively.

Operating Environment Microsoft

Woindows2000 SP4 or later

Microsoft Windows XP

Microsoft Windows 2003 Server

Microsoft Windows Vista

computer DOS/V(IBM AT compatible)computer with an Intel x86 processor

CPU Pentium Class CPU 330MHz, minimum Pentium III 1GHz, minimum recommend

Microsoft recommended Processor(1GHz, minimum recommend)

Main memory

128M, minimum 512MB, recommend

512MB, minimum 1GB, recommend.

Hard disk 85MB, minimum available space

Hardware, Limitations

Page 3: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

3SYSMAC Gateway Runtime Version1.00

(1)Use of FinsGateway Network Hardware Requirements SysmacLink Requires an OMRON SYSMAC LINK Support Board (i.e., 3G8F5-SLK21).

Only one SYSMAC LINK Support Board can be installed in one computer. The software included with the Board cannot be used with FinsGateway. The network gateway function cannot be used.

SLK (PCI) Requires an OMRON SYSMAC LINK Support Board(i.e.,3G8F7-SLK21) Up to four SYSMAC LINK Support Board can be installed in one computer

Controller Link Requires an OMRON Controller Link Support Board(i.e.,3G8F5-CLK21). Only one Controller Link Support Board can be installed in one computer. The software included with the Board cannot be used with FinsGateway.

CLK (PCI) Requires an OMRON Controller Link Support Board(i.e.,3G8F5-CLK21). Up to four SYSMAC LINK Support Boards can be installed in one computer.

Ethernet Requires an Ethernet board and an OS supported by SYSMAC Gateway. TCP/IP must be installed. TCP/IP is included in Microsoft Windows.

SerialUnit-COMx Requires a PC 95-compliant COM port and an OS supported by SYSMAC Gateway. The above COM port must be available for exclusive use by SYSMAC Gateway.Other applications not using SYSMAC Gateway cannot use the COM port simultaneously.

USB Only one port can be used simultaneously. USB port must be available for exclusive use by FinsGateway. It is not available for SYSMAC Gateway or other application.

SysmacBoard Requires an OMRON SYSMAC Board(i.e.,C200PC-ISA-01-DRM) The software included with the board cannot be used with FinsGateway.

Cs1Bus Requires an OMRON CS1BUS Interface Board(ITBC-CST01). Up to four CS1BUS Interface Boards can be installed in one computer.

Cs1Sys Requires an OMRON CS1BUS Interface Board(ITBC-CST01). Up to four CS1BUS Interface Boards can be installed in one computer.

(2)Use of SYSMAC Gateway Network Hardware Requirements Ethernet Requires an Ethernet board and an OS supported by SYSMAC Gateway.

TCP/IP must be installed. TCP/IP is included in Microsoft Windows. USB Only one port can be used simultaneously.USB port must be available for

exclusive use by SYSMAC Gateway. It is not available for FinsGateway or other application.

4. Setup Procedure

4.1. New Installation

Use the following steps to install SYSMAC Gateway for the first time: 1. Apply power to the computer, and log in as an Admin user. 2. Insert the SYSMAC Gateway installation disc into a CD drive. The install

program starts running automatically.

Page 4: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

4 SYSMAC Gateway Runtime Version1.00

3. Click “Next” to show a dialog to enter user information. 4. Enter the user information. 5. Click “Next” to show a dialog to select the type of middleware to install. Go to

Step 6 to install FinsGateway only. Go to Step 7 to install SYSMAC Gateway only. And got Step 8 to install both FinsGateway and SYSMAC Gateway.

6. In case of FinsGateway installation: 6.1. Select “FinsGateway” as the setup type.

6.2. Click “Next” to show a dialog to select network types.

Page 5: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

5SYSMAC Gateway Runtime Version1.00

6.3. Select network types to install. Click “Next” to show a dialog to start installation. Go to step 9.

7. In case of SYSMAC Gateway installation

7.1. Select “SYSMAC Gateway” as the setup type.

7.2. Click “Next” to show a dialog to start installation. Go to step 9. 8. In case of installing both SYSMAC Gateway and FinsGateway:

8.1. Select “SYSMAC Gateway and FinsGateway” as the setup type.

Page 6: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

6 SYSMAC Gateway Runtime Version1.00

8.2. Click “Next” to show a dialog to select network types of FinsGateway.

8.3. Select network types to install. Click “Next” to show a dialog to start

installation. Go to step 9.

9. Click “Install” to start installation.

Page 7: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

7SYSMAC Gateway Runtime Version1.00

10. Follow the installation guidance. 11. Restart computer.

4.2. Upgrade installation

If you use old version of FinsGateway or SYSMAC Gateway installed then use the following steps.

1. Apply power to the computer, and log in as an Admin user. 2. Uninstall the older version of FinsGateway and/or SYSMAC Gateway. 3. Install SYSMAC Gateway. Follow the “New Installation” instruction. 4. Restart computer.

4.3. Change installation configurations

Use the following steps to change the installation configuration of SYSMAC Gateway.

1. Apply power to the computer, and log in as an Admin user. 2. Stop all programs and services related to the SYSMAC Gateway and

FinsGateway. 3. Execute “Add or Remove Programs” from Windows control panel. 4. Select “SYSMAC Gateway” and execute “Change”. 5. At the maintenance dialog select “Change” and click “Next”. Then follow the

instructions.

4.4. Uninstall SYSMAC Gateway

Use the following steps to uninstall SYSMAC Gateway. 1. Apply power to the computer, and log in as an Admin user. 2. Stop all programs and services related to the SYSMAC Gateway and

FinsGateway.

Page 8: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

8 SYSMAC Gateway Runtime Version1.00

3. Execute “Add or Remove Programs” from Windows control panel. 4. Select “SYSMAC Gateway” and execute “Remove” to start un-installation. 5. Restart computer if required.

5. Remote Console

5.1. What is Remote Console

SYSMAC Gateway Remote Console is a software package that enables editing SYSMAC Gateway variables remotely from a computer that does not have SYSMAC Gateway installed. It is possible to install Network Configurator and Remote Console in a computer, read all of the SYSMAC Gateway tags (network variables) on the network, and import them to Network Configurator.

5.2. Remote Console installation

Use the following steps to uninstall SYSMAC Gateway. 1. Apply power to the computer, and log in as an Admin user. 2. Insert “SYSMAC Gateway Runtime” media. 3. SYSMAC Gateway runtime installer starts running. Please cancel to the

installer. 4. Execute SgwRemoteConsoleSetup.exe on the root folder of the install media. 5. Follow the instruction.

Note: Remote Console does not require the license key. You can install to any PCs.

Page 9: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

9SYSMAC Gateway Runtime Version1.00

5.3. Launch Remote Console

From the Windows Start menu, select All Programs | OMRON | SYSMAC Gateway | SYSMAC Gateway Remote Console.

The detailed usage will be described in Remote Console help.

5.4. Uninstall Remote Console

Use the following steps to uninstall SYSMAC Gateway. 1. Apply power to the computer, and log in as an Admin user. 2. Execute “Add or Remove Programs” from Windows control panel. 3. Select “SYSMAC Gateway RemoteConsole” and execute “Remove” to start

un-installation.

6. Installation/Operation Precautions

6.1. Adding the Plug and Play USB driver USB driver will be required when you first connect to a PLC, like CJ2 CP or NSJ series, through USB. Use the following steps to install the USB driver.

● USB limitation. There are the following limitations for using USB connection. - Only one device can be connected from PC. We cannot connet to multiple

PLC from multi USB port in a computer. - You shoul not plag off the USB cable when the port has been opened. - During the USB port opened windows cannot become hybernation mode or

stand by mode. In Vista some PC may become sleep mode and fail to open port when active. In this case please plug off the cable and plug on again.

Page 10: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

10 SYSMAC Gateway Runtime Version1.00

■ CJ-series CJ2 CPU Units

The peripheral USB port (conforming to USB 1.1, B connector) is a dedicated port for connecting SYSMAC Gateway application.

● Items Required for USB Connection Operating system Windows 2000, XP, 2003 Server, or Vista Support Application SYSMAC Gateway or FinsGateway based application USB driver Included with SYSMAC Gateway product. USB cable USB 1.1(or 2.0) cable (A connector-B connector), 5 m max.

● Installing the USB Driver The procedure for first connecting a computer to the CJ2 CPU Unit peripheral USB port is described below. It is assumed that the SYSMAC Gateway has already been installed in the computer. The installation procedure depends on the OS of the computer. The following procedures are for Windows XP and Windows 2000.

● Windows XP Turn ON the power supply to the CJ2 CPU Unit, and connect USB cable between the USB port of the computer and the peripheral (USB) port of the CJ2 CPU Unit. After the cable has been connected, the computer will automatically recognize the device and the following message will be displayed.

1. If the following window appears, select the No, not this time Option and then

click the Next Button. This window is not always displayed.

Page 11: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

11SYSMAC Gateway Runtime Version1.00

2. The following window will be displayed. Select the Install from a list of

specific location Option and then click the Next Button.

3. The following window will be displayed. Click the Browse Button for the

Include this location in the search Field, specify \USB Driver\Inf on the installer media, and then click the Next Button. The driver will be installed.

Page 12: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

12 SYSMAC Gateway Runtime Version1.00

Page 13: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

13SYSMAC Gateway Runtime Version1.00

4. Ignore the following window if it is displayed and click the Continue Anyway Button.

5. The following window will be displayed if the installation is completed

normally. Click the Finish Button.

● Windows 2000 Turn ON the power supply to the CJ2 CPU Unit, and connect USB cable between the USB port of the computer and the peripheral (USB) port of the CJ2 CPU Unit. After the cable has been connected, the computer will automatically recognize the device and the following message will be displayed.

1. The following message will be displayed. Click the Next Button.

Page 14: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

14 SYSMAC Gateway Runtime Version1.00

2. The following window will be displayed.

3. Select the Search for a suitable driver for the device (recommended) Option

and then click the Next Button. The following window will be displayed. From the list in the window, select the Specify location Checkbox and then click the Next Button.

Page 15: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

15SYSMAC Gateway Runtime Version1.00

4. Click the Browse Button, specify \USB Driver\Inf folder on the installation media, and then click the Next Button.

5. A search will be made for the driver and the following window will be

displayed. Click the Next Button. The driver will be installed.

6. After the driver has been successfully installed, the following window will be

displayed. Click the Finish Button.

● Checking after Installation 1. Display the Device Manager at the computer. 2. Click USB (Universal Serial Bus) Controller, and confirm that OMRON

SYSMAC PLC Device is displayed.

Page 16: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

16 SYSMAC Gateway Runtime Version1.00

● Re-installing the USB Driver If the USB driver installation fails for some reason or is cancelled in progress, the USB driver must be reinstalled.

● Checking USB Driver Status 1. Display the Device Manager on the computer. 2. If USB Device is displayed for Other devices, it means that the USB driver

installation has failed.

● Reinstalling the USB Driver 1. Right-click USB Device and select Delete from the pop-up menu to delete

the driver. 2. Reconnect the USB cable. The USB Driver Installation Window will be

displayed. 3. Reinstall the USB driver.

Page 17: SYSMAC Gateway Runtime Installation Guide 1. Introduction · SYSMAC Gateway Runtime Installation Guide 1. Introduction ... The above COM port must be available ... Click “Next”

©OMRON Corporation 2008 All Rights Reserved.

17SYSMAC Gateway Runtime Version1.00

6.2. Adding the Plug and Play Support Board driver

To use the PCI Controller Link Support Board or another Network Support Board that is Plug & Play, the device driver for the Board must be installed in addition to the FinsGateway installation. For details, refer to the manual included with the Board.

7. Copyrights The SYSMAC Gateway manual, and software copyrights are help exclusively by OMRON Corporation. The following are the only exceptions to this:

Microsoft MSVC runtime modules, MFC runtime modules, and Microsoft .NET Framework.

Borland Software Corporation C++ Builder runtime modules.

FlexGrid for .NET 4.0J Copyright (C)2001-2007 ComponentOne LLC.

Crownwood Software Ltd DotNetMagic Version 5.3.0

These copyrights are held by Microsoft Corporation, Borland Software Corporation, ComponentOne LLC and Crownwood Software Ltd, respectively. Omron Corporation is redistributing these files with FinsGateway in accordance with the module redistribution conditions of Microsoft Corporation, Borland Software Corporation, ComponentOne LLC and Crownwood Software Ltd. According to this contract, Omron customers are not allowed to redistribute these files.

FINS, FinsGateway and SYSMAC are trademarks of OMRON Corporation. Microsoft, Windows, Windows NT, Visual Studio, and Visual C++ are registered trademarks of Microsoft Corporation. Pentium and Intel are registered trademarks of Intel Corporation. All other company names, product names, etc. are also the trademarks or registered trademarks of the respective companies.

The symbols ™ and ® have been omitted from this manual.