8/12/2019 SYMCSP077
1/5
SYM-CSP-077Page 1
February 3, 2014
EMC 171 South Street, Hopkinton,, MA 01758 Tel. (508) 435-1000EMC
2, EMC, Symmetrix, and VMAX are registered trademarks and Enginuity is a trademark of EMC Corporation.
Other trademarks are the property of their respective owners.
Customer Service ProcedureInstalling the SymmIP_SLC SymmIP Patch for
Symmetrix VMAX Modem Systems Upgradedto Enginuity 5876.251.161
CONTENTS
INTRODUCTION........................................................................................................................................ 2
DOCUMENT CLASSIFICATION ...................................................................................................................... 2APPLICABILITY............................................................................................................................................ 2TECHNICAL CONTACT ................................................................................................................................. 2REFERENCE DOCUMENTATION.................................................................................................................... 2REVISION HISTORY ..................................................................................................................................... 2
SECTION 1 OVERVIEW......................................................................................................................... 3
SECTION 2 INSTALLATION................................................................................................................. 3
8/12/2019 SYMCSP077
2/5
SYM-CSP-077Page 1
February 3, 2014
EMC 171 South Street, Hopkinton,, MA 01758 Tel. (508) 435-1000EMC
2, EMC, Symmetrix, and VMAX are registered trademarks and Enginuity is a trademark of EMC Corporation.
Other trademarks are the property of their respective owners.
Introduction
This Customer Service Procedure (CSP) provides instructions on how install the patch that will correctSymmIP_SLC connectivity issues for Symmetrix VMAX modem customers after upgrading to Enginuity
5876. 251.161.
Document Classification
This document is confidential and intended for EMC field service personnel and partners only.
Appl icabi li ty
The information contained in this CSP applies ONLY to Symmetrix VMAX Series modem customers
who have upgraded to Enginuity 5876. 251.161.
Technical Contact
Service Planning and Systems
EMC Corporation
171 South St., Hopkinton, MA 01748
Reference Documentation
EMC Knowledgebase Article Number 173921: https://support.emc.com/kb/173921
SymmIP Users Guide Version 2.10 P/N 300-999-214 m(Rev 04)
Revision History
Revision history of this document is provided in Table 1.
Table 1. Revision History
Document No./Revision Release Date Summary of Changes
SYM-CSP-077 January 24, 2014 Initial Release.
https://support.emc.com/kb/173921https://support.emc.com/kb/173921http://www.cs.isus.emc.com/symmip/symmipuserguide2.10.pdfhttp://www.cs.isus.emc.com/symmip/symmipuserguide2.10.pdfhttp://www.cs.isus.emc.com/symmip/symmipuserguide2.10.pdfhttps://support.emc.com/kb/1739218/12/2019 SYMCSP077
3/5
SYM-CSP-077Page 1
February 3, 2014
EMC 171 South Street, Hopkinton,, MA 01758 Tel. (508) 435-1000EMC
2, EMC, Symmetrix, and VMAX are registered trademarks and Enginuity is a trademark of EMC Corporation.
Other trademarks are the property of their respective owners.
Section 1 Overview
This document applies to Symmetrix VMAX Service Processors with the following baseline configuration:
Using modem only.
Running SymmIP_SLC.
Upgraded Enginuity to 5876.251.161.
CSI Install Base must have a connection record set to SymmIP_SLC.
For customers using modem and SymmIP_SLC, the dial in connection fails after upgrading to Enginuity
5876.251.161. This is due to a permission issue within Microsoft Windows. This CSP discusses the patch
that must be installed after the upgrade to 5876.251.161 is complete.
Section 2 Installation
1. Ensure the CSI Install Base record for the system has the connection record set to SymmIP_SLC.
2. Download the patch SIPPermissions.exe from EMC Online Support from one of the following links.
The fix is the same for every Symmetrix model so any one of the following links will provide access
to the same fix:
https://support.emc.com/products/25708_Symmetrix-VMAX-40K/Tools/
https://support.emc.com/products/25708_Symmetrix-VMAX-20K/Tools/
https://support.emc.com/products/25708_Symmetrix-VMAX-10K/Tools/
3. Copy the SIPPermissions.exe file to the C:\temp directory on the Service Processor.
4. Execute the SIPPermissions.exe file by double-clicking the file or right-click the file name and select Run.
The executable will display the dialog box shown in Figure 1.
Figure 1. Dialog Box
5. Select Yesto continue.
https://support.emc.com/products/25708_Symmetrix-VMAX-40K/Tools/https://support.emc.com/products/25708_Symmetrix-VMAX-40K/Tools/https://support.emc.com/products/25708_Symmetrix-VMAX-20K/Tools/https://support.emc.com/products/25708_Symmetrix-VMAX-20K/Tools/https://support.emc.com/products/25708_Symmetrix-VMAX-10K/Tools/https://support.emc.com/products/25708_Symmetrix-VMAX-10K/Tools/https://support.emc.com/products/25708_Symmetrix-VMAX-10K/Tools/https://support.emc.com/products/25708_Symmetrix-VMAX-20K/Tools/https://support.emc.com/products/25708_Symmetrix-VMAX-40K/Tools/8/12/2019 SYMCSP077
4/5
SYM-CSP-077Page 1
February 3, 2014
EMC 171 South Street, Hopkinton,, MA 01758 Tel. (508) 435-1000EMC
2, EMC, Symmetrix, and VMAX are registered trademarks and Enginuity is a trademark of EMC Corporation.
Other trademarks are the property of their respective owners.
6. When the executable completes the Patch Complete dialog box will display, indicating the patch
installation is complete (Figure 2).
Figure 2. Patch Complete Dialog Box
7. Select OK.
8. Reboot the Service Processor.
9. Log in to the Service Processor and open EMCRemote. EMCRemote should be set to TCP\IP as
shown in Figure 3. If not follow the procedures to enable SymmIP in the SymmIP Users Guide
Version 2.10 P/N 300-999-214 m(Rev 04). Navigation to this manual is as follows:
Go to the GS Intranet at http://www.cs.isus.emc.com/.
From the home page select Product/Technical Section> Remote Support Specific > SymmIP.
Select the link to the users guide.
Figure 3. EMCRemote Host set to TCP/IP
10. Test the remote dial in through Remote Connection Console (RCC) (SymmIP_SLC).
Note:If the CSI connection record has been updated to SymmIP_SLC but the RCC dialer has not yet
been updated with the Type SPC for SymmIP_SLC (Figure 4) and only shows SRC
(Symmremote_SLC) you will have to perform a manual SymmIP_SLC dial out attempt (Figure 5).
http://www.cs.isus.emc.com/symmip/symmipuserguide2.10.pdfhttp://www.cs.isus.emc.com/symmip/symmipuserguide2.10.pdfhttp://www.cs.isus.emc.com/http://www.cs.isus.emc.com/http://www.cs.isus.emc.com/symmip/symmipuserguide2.10.pdfhttp://www.cs.isus.emc.com/symmip/symmipuserguide2.10.pdf8/12/2019 SYMCSP077
5/5
SYM-CSP-077Page 1
February 3, 2014
EMC 171 South Street, Hopkinton,, MA 01758 Tel. (508) 435-1000
Figure 4. Type SPC for SymmIP_SLC
Figure 5. Manual Phone Number Entry
EMC2, EMC, Symmetrix, and VMAX are registered trademarks and Enginuity is a trademark of EMC Corporation.
Other trademarks are the property of their respective owners.