Upload
others
View
8
Download
0
Embed Size (px)
Citation preview
Swing Door Operator
DORMA ED 200
2
DORMA ED 200 Swing Door Operator
As a powerful automaticelectro-hydraulic swing dooroperator, the DORMA ED 200is suitable for standard andfor large and heavy doors. It can be adapted to a widerange of applications andmounting requirements andoffers numerous adjustablefeatures. When the permanentopen function is activated,the door is held open by asolenoid valve in a way whichensures stability and opera-tional silence.
The softline cover can beextended to the full doorwidth providing an opticalelegant solution. TheDORMA ED 200 – availableup to size EN 7 – is alsosuitable for fire and smoke doors, even with itspermanent open function.Double-leaf doors may alsobe equipped with an integrated door coordinator(ED 200 ESR) which, whenviewed from the outside, isconcealed behind the cover.
As an alternative, we nowoffer our new VARIO cover(page 16).It can also be installed inemergency exits and escaperoutes. It can likewise be combined with accesscontrol systems.
Universal application, simpleinstallation, reliable function
DIN18263/T4
3
2 Two variants (EN 4–6, EN 7), to suit all applications.
2 One version for both doordirections (left-handed/right-handed) and mount-ing positions (hinge (pull)side/opposite hinge (push)side).
2 Quick and easy mountingthanks to two auxiliaryscrews and plug-connected cabling.
2 Reliable function even inthe case of heavy-usedoors and entrances exposed to various weatherconditions.
2 Optimum adaptability toindividual requirements –e.g. in hospitals, homesfor the elderly, facilitiesfor the disabled, restau-rants, security areas and laboratories.
2 Numerous control options.
2 Integrated door coordinatorfor double-leaf doors.
2 Suitable for connection.of tested infrared safetysensors.
Features and benefits
4
Lintel depth (mm)
275
280
250
225
200
175
150
125
100
75
50
25
0880 900 920 940 960 980 1000 1020 1040 1060 1080 1100
Minimum door leaf width (mm)
30
615 alternatively 850 mm
Door leaf
Applications
DORMA ED 200 Technical data and features
Applications
Single- and double-leaf standard doors
Single- and double-leaf fire and smoke doors(only with standard arm)
Opening width for single-leaf doors (Door leaf width)1)
Operator variant EN 4-6
with standard arm 1590 mm to 1400 mm
with slide channel (mounting on the hinge [pull] side) 880 mm to 1400 mm2)
with slide channel (mounting on the opposite hinge [push] side) 1800 mm to 1400 mm
with parallel arm 1680 mm to 1400 mm
Operator variant EN 7
with standard arm 1750 mm to 1600 mm
with slide channel (mountingon the hinge [pull] side) 1880 mm to 1600 mm2)
with slide channel (mounting on the opposite hinge [push] side) 1800 mm to 1600 mm
with parallel arm 1680 mm to 1600 mm
Opening width for double-leaf doors1)
(for applications with symmetric door leaf widths)
Operator variant EN 4-6
with standard arm 1284 mm to 2800 mm
with slide channel (mountingon the hinge [pull] side) 1750 mm to 2800 mm2)
with slide channel (mounting on the opposite hinge [push] side) 1600 mm to 2800 mm
with parallel arm 1360 mm to 2800 mm
Operator variant EN 7
with standard arm 1284 mm to 3200 mm
with slide channel (mountingon the hinge [pull] side) 1750 mm to 3200 mm2)
with slide channel (mounting on the opposite hinge [push] side) 1600 mm to 3200 mm
with parallel arm 1360 mm to 2800 mm
Door leaf weight, max. 250 kg
Lintel depth
with standard arm –40 mm to 500 mm
with slide channel (mounting on the hinge [pull] side) –20 mm to 280 mm2)
with slide channel (mounting on the opposite hinge [push] side) 0 mm
with parallel arm –40 mm to 160 mm
1) Door widths beyond the above-mentioned ranges ondemand!
2) Attention! Please consider the minimum door leaf widthaccording to the above diagram.Additionally a special slide channel or a mounting position different from the drawings in this brochurecould be required. Special solutions on demand!
Technical data of the drive unit
Closing force (2 operator types) EN 4 – 6 (adjustable)
EN 7 (fixed)
Dimensions Height 106 mm
Depth 133 mm
Width 665 mm
Continuous/extended cover for single-and double-leaf door operators X
Weight per operator 18 kg
One operator variant for mounting on the hinge (pull) and opposite hinge (push) side, and LH (ISO 6) and RH (ISO 5) doors x
Power consumption, max. 250 W
Supply voltage 230 V, 50/60 Hz
Power supply for external accessories
with control board A 800 mA at 12/24 V AC;600 mA at 24 V DC
with control board B 1500 mA at 12/24 V AC;1000 mA at 24 V DC
Stabilized power supply (e.g. for smoke detectors)
with control board B 100 mA at 24 V DC
Class of protection IP 20
TÜV type-approved x
Compliant with the Low Voltage Directive and the EMC Directive x
Manufactured to ISO 9000 x
Applications ED 200 mounted on hinge (pull) side with slide channel
5
7
2
6
1
5
3
4
115°75°
25°
1 Adjustable opening speed2 Adjustable backcheck1 + 2 Adjustable opening time3 Adjustable closing speed4 Adjustable delayed action3 + 4 Adjustable closing time5 Easy manual operation with bypass valve6 Backcheck range for manual operation7 Adjustable opening angle, adjustable hold
open time
Adjustable parameters of the driving phase
Functions and adjustment possibilities
Opening angle, max.
with standard arm 115°
with slide channel (mounting on the hinge [pull] side) 90°
with slide channel (mounting on the opposite hinge [push] side) 90°
with parallel arm 90°
Adjustable opening time ≥ 1,5 s
Adjustable closing time ≥ 3 s
Adjustable hold open time 0 s – 30 s
Adjustable backcheck x
Adjustable delayed action x
Adjustable wall blanking for safety sensors x
Prepared for connection of the following accessories
Standard arm, slide channel, parallel arm x x
DORMA IRS-2 infrared safety sensors (mounting on the hinge [pull] and opposite hinge [push] side) x x
Door locking device x x
Electric strikes (fail-safe/fail-secure principle) x x
DORMA SVP emergency exit motor lock with self-locking action – x
Access control system (DORMA AutoSwitch) – x
Activators (Pushbutton, Radar movement detector ...) x x
Radio remote control x x
External program switch (integrated 3-position program switch as standard) x x
Smoke detectors also with integrated power pack* – x
* 1 x lintel-mounted RM-ED or RM when bottom edge of lintel to bottom edge of smoke-sealed ceiling < 1 mIn addition: 2 x ceiling-mounted RM when bottom edge of lintel to bottom edge of smoke-sealed ceiling > 1 m
Function programs
Control Controlboard A board B
Off x x
Automatic x x
Permanent open x x
Exit only – x
Nurse-bed-function for double-leaf doors (only in combination with special module SM 206) x x
Special functions
Airlock function (only in combi-nation with door reed contact TK) X X
Timed airlock function (only in combination with special module SM 208 and door reed contact TK) X X
Night-/bank function – x
Push&Go function (only in com-bination with Push&Go module) X X
Flip-flop-function (only in combina-tion with special module SM 202) X X
Door closer function under cut-out conditions x x
x standard X optional
6462,5
508,564
15
280
315 50
38
5,5
10
6
665
36
X
133
24,5
45
11
2
DORMA ED 200 for single-leaf doors
Mounting on the opposite hinge (push) side with standard arm for LH (ISO 6) and RH (ISO 5) doors(example: RH [ISO 5] door)
1)
30
17 12 4
7
175280
5981
06
64
36
62,5508,5
64
15
665
133
40
12
3
23
Mounting on the opposite hinge (push) side with slide channelfor LH (ISO 6) and RH (ISO 5) doors(example: RH [ISO 5] door)
1)
20
10
6
64
36
57,5503,5
64
665
250
350
30
17 12 4
7
598
615
133
40
12
3Mounting on the hinge (pull) side with slide channelfor LH (ISO 6) and RH (ISO 5) doors(example: RH [ISO 5] door)
1)
10
6
64
36
57,5503,5
64
665
A
15
9,5
60
48,5
14
,510
6
82133
20 350
53,5
48 29
5090
X
Mounting on the hinge (pull) side with parallel armfor LH (ISO 6) and RH (ISO 5) doors(example: RH (ISO 5) door)
1)
(not approved for fireand smoke doors)
(not approved for fire and smoke doors)
(not approved for fire and smoke doors)
6
F
Lintel depth X Standard arm–40 to 120 mm var. 01
80 to 240 mm var. 02240 to 360 mm var. 03360 to 500 mm var. 04*1)optional axle extension
(see page 18)* maximum axle extension : 48 mm,
maximum closing force: EN 6 maximum door leaf weight: 120 kg
Mounting plates/axle extension
95482113 30 73
Axle extension/spindle extension
82
1 34 6
6 84
,5 10
0
649629
575319,5
7446,5
20
713
2808
,5
h1 –
12
,5
h1 = 21(Standard)
482113 30
82
1 34 6
6 84
,5 10
0
713
280
15
h1 –
15
h1 = 30(Standard)
649629
575319,5
7446,520
Axle extension/spindle extension
482113 30
82
1 34 6
6 84
,5 10
0
649629
575329,5
7420
128
350
20
h1 –
7
h1 = 13(Standard)
602,5
Axle extension/spindle extension
Lintel depth X A* Parallel arm–40 to 0 mm 50 var. 01
0 to 40 mm 50 var. 0240 to 100 mm 80 var. 03
100 to 160 mm 80 var. 04* For dimension A see drawing on the left 482113 30350
82
1 34 6
6 84
,5 10
0
649629
575329,5
7420
12 8
56
,5
h1 +
43
,5
h1 = 13(Standard)
602,5
9573
Axle extension/spindle extension
Lintel depth: 0 mm1) optional axle extension
(see page 18)
Lintel depth:– 20 mm to 280 mm (Attention! Please consider theminimum door leaf width accordingto the diagram on page 4)1) optional axle extension
(see page 18)
Min.
90°
Min. distanceX up to 40 mm = 200 mmX up to 100 mm = 260 mmX up to 160 mm = 290 mm
7
Mounting on the opposite hinge (push) side with standard arm
8
F
36
64
62,5508,5
64
15
280
315 50
38
5,5
36
Mounting on the hinge (pull) side with slide channel64
36
57,5503,5
64
20
250
350
30
17 12 4
7
586
600
DORMA ED 200 for double-leaf doors
Passive leaf
Active leaf
Mounting on the opposite hinge (push) side with slide channel64
36
57,5503,5
64
20 280
30
17 12 4
7
586
600
(not approved for fireand smoke doors)
(not approved for fireand smoke doors)
Mounting on the hinge (pull) side with parallel arm64
36
57,5503,5
64
A20 350
53,5
48 29
5090 Active leaf
Passive leaf
(not approved for fireand smoke doors)
9
X
36
133
45
11
2
133
40
12
3
1)
1)
Active leaf
B = min. 1284 mm
Passive leaf
B = min. 1750 mm Special door widths on demand
40
12
3
133
48,5
14
,510
6
82133
X
159,
560
Passive leaf
B = min. 1360 mm Special door widths on demand
Active leaf
B = min. 1600 mm
1)
Lintel depth X A* Parallelarm
–40 to 0 mm 50 var. 010 to 40 mm 50 var. 02
40 to 100 mm 80 var. 03100 to 160 mm 80 var. 04
* For dimension A see drawingon the left
Lintel depth X Standardarm
–40 to 120 mm var. 0180 to 240 mm var. 02
240 to 360 mm var. 03360 to 500 mm var. 04*1)optional axle extension
(see page 18)* maximum axle extension: 48 mm
maximum closing force: EN 6 maximum door leaf weight: 120 kg
Lintel depth:0 mm1) optional axle extension
(see page 18)
Lintel depth:–20 mm to 280 mm(Attention! Please consider theminimum door leaf width according to the diagram onpage 4)1) optional axle extension
(see page 18)
Mounting on the hinge (pull) and opposite hinge (push) side
615
36
6457,5
503,564
20
250
350
47
17 12 64
598
62
118
10
DORMA ED 200 for “contraflow traffic”
The decisive advantage ofthe double-door “contraflowtraffic” lies in the fact thateach door leaf controls justone direction, so separatingthe ingress and egress flowsas users enter or leave the building or area. Thereis also the advantage that
passage through the doorstakes place immediately because they always open inthe walking direction. Thisapplication is therefore especially suitable for doorsin which there is a constantor occasionally heavy flow ofusers like the entrances to
department stores, leisurefacilities and administrationbuildings, but also for thekitchen entrances of largerestaurants and hotels. Thetwo swing door operatorsoperate individually: Thedrive unit of each operatorcontrols all the parameters,
such as opening, closingand hold open times, andalso the functions triggeredby the safety sensors.
(not approved for fireand smoke doors)
11
64
36
62,5
508,5
64
15
B
34
12644
1
315
280
50
64
11
8
1)1)
Also available with 2 slide channels
Hinge (pull) side:Slide channel, pullingLintel depth:–20 mm to 280 mm(Attention! Please considerthe minimum door leafwidth according to thediagram on page 4)1) optional axle extension
(see page 18)
Lintel depth X Standard arm –40 to 120 mm var. 01280 to 240 mm var. 02240 to 360 mm var. 03360 to 500 mm var. 04*1)optional axle extension
(see page 18)* maximum axle extension: 48 mm
maximum closing force: EN maximum door leaf weight: 120 kg
Mounting on the opposite hinge (push) side with standard arm
6462,5
508,564
15
280
315 50
38
5,5
10
6
665
36
12
DORMA ED 200 Fire and smokedoors
In the case of fire and smokedoors, the ED 200 is alwaysfixed on the opposite hinge(push) side with a standardarm. Such systems are referred to as hold opensystems. Compliant with theGerman guidelines governinghold open systems issued bythe German Institute for CivilEngineering DIBt (Berlin),hold open systems mustalways consist of the 4 following components:1.Activator (complied
with by RM-ED or RM)
2.Pushbutton (with “Türschließen” wording)
3.Power supply and4.Hold open system
(3. and 4. complied withby ED 200).
The ED 200 has the approval for application atfire and smoke doors. Pleaserefer to the chart on page 5for all possible combinationsof operators and DORMAsmoke detectors. Theconnection of smoke detec-tors, supplied by others, isalso possible. The number of
smoke detectors normallydepends on the distancebetween the bottom edge ofthe lintel and the bottomedge of the smoke-sealedceiling. Please see page 14for number and positioningof smoke detectors.Depending on requirements,individual or several electricstrikes can be connectedwhich must operate inaccordance with the fail-secure principle. In addition,it must be ensured that theyare installed in the correct
(approved) position. For allcomponents of this system,including the electric strikes, approvals must beobtained in accordance with the German Institutefor Civil Engineering (DIBt).
Single-leaf doorsfor LH (ISO 6) and RH (ISO 5) doors (example: RH (ISO 5) door)
F
Mounting on the opposite hinge (push) side with standard arm
36
64
62,5508,5
64
15
280
315 50
38
5,5
36
(Drawing for ED 200, ED 200 ESR 1/2 and ED 200 ESR)
Double-leaf doors
Passive leaf
13
F Approval CertificationThe DORMA ED 200 auto-matic swing door operator isapproved in Germany by theMPA (State Material TestingAuthority) NRW Dortmund inaccordance with DIN 18263,Part 4, and is subject tothird-party quality assuranceverification. In combinationwith the DORMA RMZ 2smoke detector with integra-ted power pack and DORMAsmoke detectors, it is approvedby the German Institute forCivil Engineering DIBt (Berlin)for use on single- and double-leaf fire and smoke doors provided that this is allowedby the approval certificate for the door concerned.
The DORMA ED 200 hasbeen tested and approved ashold open system for single-and double-leaf doors inaccordance with the Germanguidelines governing holdopen systems.
Fire and smoke doors withlintel depths of up to 500mm may also be equippedwith the ED 200 swing dooroperator, as it is also approvedby the German Institute forCivil Engineering DIBt withstandard arm variant 04.
Lintel depths of up to 500 mm
36
B
X
1)
Door coordinatorThe ED 200 is always mountedon the opposite hinge (push)side of single- and double-leaf fire and smoke doorswith standard arm. The twooperators, which are concea-led behind the continuouscover, operate according tothe master-slave principle:The active leaf operatorcontrols all the parameters(e.g. hold open time) andalso the functions actuatedby the safety sensors (IRS-2). Both operators are fed internally by an externalpower supply. In the event of a fire, the door
can be activated by theDORMA RM-ED and RMsmoke detectors (see page5, 14/15). The connectionof smoke detectors suppliedby others is also possible.
According to EN 1158, adouble-leaf swing door operator must be equippedwith a mechanical doorcoordinator. The purpose ofthe door coordinator is toensure that even under cut-out conditions the two doorleaves close in a correctsequence (passive leaf beforeactive leaf), so producing a tight barrier seal. With two integrated versions andthe external version, DORMAoffers three door coordinatorsfor the ED 200 (see page 16).
Lintel depth X Standard arm–40 to 120 mm var. 01280 to 240 mm var. 02240 to 360 mm var. 03360 to 500 mm var. 04** maximum axle extension: 48 mm
maximum closing force: EN 6 maximum door leaf weight: 120 kg
1)optional axle extension(see page 18)
Active leaf
Does the distance between the bottom edge of the ceiling and the bottom edge of the lintel exceed 1,0 m on one or on both side/s of the door?
Does the door width exceed 3,0 m?
YES
YESNO
NO
1) For opening widths beyond 4 m further smoke detectors are required.
230 V
≤ 1
m
max
. 0
,1 m
1 Lintel-mounted detector
230 V
≤ 3 m
≤ 1
m
230 V
0,6 – 2,4 m
≤ 1
m
> 3 m
0,6 – 2,4 m
230 V
> 3 m
≤ 1
m
0,6 – 2,4 m
230 V
> 1
mm
ax.
0,1
m
0,6 – 2,4 m
> 1
m
230 V
1 Lintel-mounted detector
2 Ceiling-mounted detectors1) 2 Ceiling-mounted detectors1)
2 Ceiling-mounted detectors + 1 Lintel-mounted detector1)
2 Ceiling-mounted detectors + 1 Lintel-mounted detector1)
14
DORMA ED 200 Smoke detectors for fireand smoke doors
Number and positioning of smoke detectors
For application at fire and smoke doors: RM-ED smoke detector RM smoke detector
15
53
52195
170
32
Ø 4,5
F Approval CertificationThe smoke detectors DORMA RM-ED and RM areapproved by the GermanInstitute for Civil Engineering
DIBt (Berlin) and are subject to third-party qualityassurance verification.
80
80
12,5
schliessenTür
As universal optical smokedetector, the DORMA RM is suitable for lintel- andceiling-mounting. It is con-nected to a DORMA RM-EDsmoke detector or a DORMAED 200 swing door operator.It is ready for connection offurther DORMA RM smokedetectors, a manual releasepushbutton and a light indicator.
Dimensions: 53 x 195 x 52 mm
This pushbutton is designedto release hold-open devicesby hand. Where hold-opendevices with free-swing door
closers are applied at fireand smoke doors, the instal-lation of a manual releasepushbutton is compulsory
according to the guidelinesof the German Institute forCivil Engineering (DIBt),Berlin.
DORMA HT manual release pushbutton for hold-open devices
378
34
357,5
30
The optical DORMA RM-EDsmoke detector can beinstalled as ED 200 lintel-mounted smoke detector.
Dimensions: 34 x 378 x 30 mm
DORMA RM-ED lintel-mounted smoke detector
DORMA RM-EDRed/green light indicator,test input for functional test,power supply: 24 V DC,power consumption: 75 mA,maximum load current: max. 2 A at 60 V AC.
E 6/C 0 (silver-coloured)Order No. 64840001RAL 9016 (white)Order No. 64840011Special colourOrder No. 64840009
DORMA RMRed/green light indicator,test input for functional test,power supply: 24 V DC,power consumption: 25 mA,maximum load current: max. 2 A at 60 V AC.
E 6/C 0 (silver-coloured)Order No. 64820001RAL 9016 (white)Order No. 64820011Special colourOrder No. 64820009
DORMA HTsingle-pole changeovercontact, standard frame, redlabel with white inscriptionreading “Tür schliessen”
flush-mountingOrder No. 19144601175
surface-mounted box forDORMA HTOrder No. 05158533332(not displayed)
RM-NThe DORMA RM-N serialsmoke detector detectssmouldering fires as well asopen fires with smoke emis-sion at an early stage. It isdesigned for application assecond or third detector forhold-open devices and incombination with RMZ-EDand RM detectors.Operating voltage 24 V DCWhiteOrder No. 64830000
45
∅ 100
DORMA RM lintel- and ceiling mounted smoke detector DORMA RM-N ceiling-mounted smoke detector
16
DORMA ED 200Door coordinatorfor double-leaf fire andsmoke doors
ED 200 ESR with integrated door coordinator
ED 200 ESR 1⁄2 for partially automated double-leaf doors
The ED 200 ESR combinesoperational reliability andexcellent optical characte-ristics with a minimum ofinstallation and maintenancecosts. The door coordinator isinstalled in the factory andlocated behind the conti-nuous cover of the double-leaf door system and noadditional slide channels andpivot bearings are requiredon the hinge side. Thanks to the fact that the door
coordinator is installed in the factory, no additionalinstallation work is necessarycompared to the stand-aloneoperator, reducing bothinstallation time and installa-tion costs to a minimum. The hydraulic system worksin a closed circuit, whichdoes not require readjust-ment and renders the systemmaintenance-free. Furthermore all arm compo-nents of the ED 200 systemcan still be used. The ED
200 ESR is supplied as aclosed unit so that you onlyneed a single order numberand no extensive search inthe price list and the plan-ning documents is required. Of course the ED 200 ESR is suitable for installation atfire and smoke doors and itsintegrated door coordinatorensures – also in this combi-nation – a proper closingbehaviour of the door undercut-out conditions.
When applied at fire andsmoke doors, the wholesystem has to be planned ashold-open device (see page14/15).
The low-priced applicationfor double-leaf doors (fireand smoke doors)In general both door leavesof a double-leaf door areautomated, however, forpedestrian traffic it is suffi-cient to automate only onedoor leaf. This is where theED 200 ESR 1/2 comes into
play as it is the low-priceapplication that automatesonly one of the two door leaves. While the active leafis opened full-automatically,the passive leaf can be operated manually and hasthe function of a door closer.Thanks to its integratedhold-open device, both door
leaves can be set toPermanent Open while nofurther components arerequired. Of course the ED 200 ESR 1/2 is suitablefor application at fire andsmoke doors and ensures,due to its integrated doorcoordinator – also in thiscombination – the safe
closing behaviour of the doorunder cut-out conditions.When applied at fire andsmoke doors, the wholesystem has to be planned ashold-open device (see page14/15).
DORMA ED 200 with VARIO cover:Always the suitable operatorin stockWith the new ED 200, wenow offer a ready-for-instal-lation swing door operatorfor double-leaf doors that isavailable within a short period of time. A furtherbenefit of this new system isits adaptability to any width
you may desire to cover. Ithas a variable centrepiecebetween the two equallysized standard operatorparts consisting of the coverand the base plate. Thanksto the innovative VARIOcover, you can cut the ope-rator cover to the desiredlength on the building site.
All parts are connectedwhile covers hide the cuttingedges. The VARIO cover can also be combined with the well-established ESR integrateddoor coordinator and theESR 1/2 version.
1 12 23
1. Standard cover2. Cover for cutting edge3. VARIO cover
17
28015
15280
Passive leaf/opposite hinge (push) side
Active leaf/opposite hinge (push) side
81
142 160
143 428
280
Passive leaf/opposite hinge (push) side
Active leaf/opposite hinge (push) side
ITS 96 GSR/GSR-EMF ITS GSR/Pivot block
Passive leaf Active leaf
48
,56
9
70
90
30
133
10
6
70
68 141
280
30
40
30
96
,5
31
ED 200 with ITS 96-GSR-EMF
ED 200 with TS 93-B door closer without continuous cover
ED 200 ESR 1⁄2 behind continuous cover
DORMA ED 200 Partially automateddouble-leaf doors
X
133
133
48,5
14
,510
6
82133
X
18
DORMA ED 200 Arm versionsand accessories
Arm versions
DORMA offers a competitiverange of arms and axleextensions in order to copewith all door versions andways of mounting. Apartfrom a standard arm, also aslide channel and a parallelarm are available.The standard arm is espe-cially suitable to transfer themaximum force onto thedoor leaf and is appliedwhere the system is mounted
on the opposite hinge side(push side). The joint can be openedeasily what facilitates theinstallation considerably.The standard arm pushesthe door in opening direc-tion and offers the ED 200operator enough power forinstallation at fire andsmoke doors.The slide channel is suitablefor installation on the hinge
side (pull side) and on theopposite hinge side (pushside). Apart from its appea-ling design, it offers thebenefit that it can also pullthe door. However, due to its force progression, theslide channel is not suitablefor application at fire andsmoke doors.The parallel arm is adequatewhere the operator is installed on the hinge side
(pull side) and when smalldoor leaves have to be auto-mated. Furthermore linteldepths of up to 160 mmcan be handled. All these arm versions aresupplied with an axle extension. When required,additional axle extensionsare available as an option in order to compensate differentials in height.
with standard arm Height H mm ....... D mm .....Y mm Order No.13* 6 30 1942525115021* 14 38 1942525215030* 23 47 1942525315048* 41 65 1942525415073* 66 90 1942525615095* 88 112 19425255150
with slide channel13* 14 47 1943320115021* 22 55 1943320215030* 31 64 1943320315048* 49 82 19433204150
with parallel arm 13* 53,5 1942520415021* 61,5 1942520115030* 70,5 1942520215048* 88,5 1942520315073* 113,5 1942520615095* 135,5 19425205150
* Part of the scope of delivery
Optional axle extension for variable height increase of ED 200 swing door operators
D Y
ED 200
ED 200
D Y
Y
H
19
DORMA ED 200 Wiring diagrams
Connections
01 Feeder
2a Emergency pushbuttonFunction: Emergency off
2b Emergency pushbuttonFunction: Emergency stop
03 Two-pole-and-earth socket
04 Mechanical PGS externalprogram switch
05 Electronic PGS externalprogram switch
06 Pushbutton
07 Pushbutton, inside
08 Pushbutton, outside
09 Door locking device
10 Radar, inside
11 Radar, outside
12 Key switch
13 ED 200
14 ED 200 with continuouscover
15 ED 200 for “contraflowtraffic”
16 RM-ED smoke detector
17 RM smoke detector,opposite hinge (push) side
18 RM smoke detector,hinge (pull) side
19 Manual release switch,with “Tür schließen”wording
ED 200
6 x 0,8 mm
4 x 0,8 mm
4 x 0,8 mm
4 x 0,8 mm
2 x 0,8 mm
18
13
16
9
19
17
NYM 3 x 1,5 mm2
L1 NPE
3
1
10 A
2 x
0,8
mm
4 x
0,2
5 m
m
8 x
0,8
mm
4 x
0,8
mm
2 x
0,8
mm
7 10 5 4 12
4 x
0,2
5 m
m
11
2 x
0,8
mm
8
4 x
0,8
mm
2b2a
ED 200 for single-leaf doors
19
6 x 0,8 mm4 x 0,8 mm
4 x 0,8 mm
2 x 0,8 mm
1816
17
NYM 3 x 1,5 mm2
L1 NPE
3
1
10 A
2 x
0,8
mm
4 x
0,2
5 m
m
8 x
0,8
mm
4 x
0,8
mm
2 x
0,8
mm
7 10 5 4 12
4 x
0,2
5 m
m
11
2 x
0,8
mm
8
4 x
0,8
mm
2b
2a
ED 200
2 x 0,8 mm
9
14
2 x 0,8 mm
9
ED 200 for double-leaf doors
ED 2003 x 1,5 mm
L1 NPE
2 x
0,8
mm
4 x
0,2
5 m
m
8 x
0,8
mm
4 x
0,8
mm
2 x
0,8
mm 9
15
3
1
10 A
je 2 x 0,8
12 4 5 10 6
2 x
0,8
mm
4 x
0,2
5 m
m
8 x
0,8
mm
4 x
0,8
mm
2 x
0,8
mm
6 10 5 4 12
2 x
0,8
mm
2b
2a
ED 200 for “contraflow traffic”
20
DORMA ED 200 Example combinations
Suitably equipped for the requirements of handicapped people: The rest room for handicapped people
Public buildings must haverest rooms that are tailoredto the requirements of handicapped people.However, special care mustbe devoted to the needs of wheelchair drivers. A corresponding room layout isas important as the availabi-lity of sufficient space. Theaccessibility with the aid ofan automatic door operatoris likewise important forhandicapped people and can,among others, be realizedwith a special key switch,which triggers an openingpulse. In case there is a person inside the rest room,the door can be locked viapushbutton (locking viaelectric strike) while a red-green display indicates thedoor status. Emergency sensors may be integratedinto the door system if desired. As you see, DORMAtakes care that every specialrequirement is considered.
10 A
PENL1
2 x 0,8 mm
3 x
1,5
mm
4 x
0,8
mm
2 x
0,8
mm
2 x
0,8
mm
2 x
0,8
mm
2 x
0,8
mm
4 x
0,8
mm
6 x 0,8 mm
3 x
1,5
mm
200 x 125 x 77 mm
Auf Verriegelt
12
2
ED 200
3
1
57 8
6 9
10 11
4
inside outside
ED 200 for rest rooms for the disabledConnections
11 Feeder: 230 V, 50/60 Hz12 Two-pole-and-earth socket
(by others)13 Junction box (by others)14 DORMA ED 20015 Fail-safe lock, 24 V DC16 Alarm siren with signal
lamp (red)17 Palm pushbutton with
disabled symbol18 Concealed/flush-mounted
emergency pushbutton,located behind emergencybreak glass
19 Concealed/flush-mountedsignal lamp (red)
10 Concealed/flush-mountedpalm switch, with“open/locked” wording
11 Flush-mounted pull switch,for emergency opening
12 Auxiliary drive unit, housedin external cover
21
Application of the ED 200 swing door operator in smoke and heat ventilation systems
Smoke and heat ventilationsystems are applied in preventing fire protectionwith the following objectives:2 To evacuate smoke and
heat in the event of a fire.2 To keep emergency exits
and escape routes freefrom smoke and gas.
2 To create a smoke-freelayer and to facilitate firefighting.
2 They can also be used forventilation purposes (airsupply/air withdrawal).
2 To open air outlets likewindows and dome lightsin the event of a fire.
2 Automatic and remoteactivation.
2 To supply and to withdrawair.
A smoke and heat ventilationsystem consists of a smokeoutlet, fire detectors, a
control unit and an air supply opening.In smoke and heat ventilationsystems, the ED 200 ismounted to doors serving asair supply openings. Thesedoors are designed to createa balance between the airinflow and the outflow ofgas in the roof area of thebuilding (e. g. windows).
The following system solutions are approved as airsupply openings: 1.ED 200 with USV
emergency power supplyunit
2.ED 200 Inverse(see page 22 for “Mechanicalopening under cut-out conditions”)
ED 200 with USV emergency power supply unit
The drawing shows an example for an air supplyopening. In contrast to smoke and heat ventilationsystems, equipped with the ED 200 Inverse, the ED 200 operates in dailyuse (without activation of the smoke and heat ventilation system) as properly and reliable asusually, which allows alsoheavy usage of the door. On activation of the smokeand heat ventilation system(floating opening contact),the ED 200 opens the door which remains openuntil the smoke and heatventilation system has beenreset. In order to ensure thisfunction for a certain periodof time even under cut-outconditions, the ED 200 isequipped with an emergencypower supply unit integratedin its 230 V-wiring. In addi-tion to the emergency power supply unit, the system isequipped with a power overload protection. If thepower consumption falls
below an admissible value,the emergency power supplyunit switches to emergencymode within 20 ms.
The following componentsmust be installed whenusing the ED 200 in the airsupply opening of a heatand smoke ventilationsystem:
2 Emergency power supplyunit MT 700 USV
2 Special module SM 202
ED 200 + SM 202 special module
pushbutton
Door status of smoke and heat ventilation system
electric strike plate
radarNYM 3 x 1,5 mm2
USV emergency power supply unit
Feeder 230 V/AC
Example
22
DORMA ED 200 Example combinations
ED 200 + special drive unit
2 x 0,8
Feeder 230 V ~
NYM 3 x 1,5 mm2
TV
2 x 0,8
ED 200 Inverse (mechanical opening under cut-out conditions)
The ED 200 Inverse is especially suitable for largebuildings such as airports,theatres or congress centres.In the event of an emergency,the ED 200 activates doorseven under cut-out conditionsin order to make escape routes available. For thisapplication, the operatingprinciple of the ED 200 is reversed: The operatoractuates the door to open byusing the energy stored inthe integrated door closer,then the door is closed by
motor power. The openingwidth must be limited by an external door stop. In contrast to the ED 200 withemergency power supplyunit, the ED 200 Inversecannot be connected to aradar motion detector; it is activated via push-button.The ED 200 Inverse can perform 3 different operating principles.
System solution 1Timed closing action. TheED 200 Inverse is activatedvia pushbutton and opensthe door for an adjustablehold open time from 0 to100 s. On expiry of thisperiod, the door is closedautomatically. The followingcomponents are required for this system solution: 2 Operator variant ED 200
Inverse2 Special module SM 2022 Door locking device
TV 2002 Pushbutton for activation
System solution 2Flip-flop-function (positivelyactivated closing action)Pressing the pushbuttoninstitutes the ED 200 toopen the door. The doorremains open until the doorclosing is activated by pressing the pushbuttonagain. The following components are required forthis system solution:2 Operator variant ED 200
Inverse2 Special module SM 2022 Door locking device
TV 2002 Pushbutton for activation
System solution 3DORMA TMS door manage-ment system (for emergencyexits and escape routes).The ED 200 is approved forinstallation in emergencyexits and escape routeswhen controlled by theDORMA TMS door manage-ment system. In the event of an emergency, the door terminal institutes the doorto open. The following components are required forthis system solution:2 Operator variant ED 200
Inverse2 Special module SM 2022 Door locking device
TV-DCW2 Door terminal TL-TMS
SummaryThe ED 200 Inverse can beinstituted to open a door via: 2 Pushbutton2 Power failure 2 Emergency pushbutton2 Smoke detector2 A higher-level fire
detection system or hazardwarning system
2 Activation from centralcontrol position
TV 200 electrical locking device TL-TMS door terminal SM 202 special module
23
RM
Radar
BMA
SVP-S2X DCW® I/O DCW®
DCW® Junction box
SVP-A
SVP 2000KÜ
ED 200TVDCW®
TL TMS
Concealed/ flush-mounted socket
ST 32 DCW® outside
Feeder 230 V ~
Feeder 230 V ~
SVP 2000
SVP-S22-DCW® SM24
ST
ED 200
SVP-A
KÜ
2 x 0,8
Feeder230 V ~
NYM 3 x 1,5 mm2
Emergency exit control system
The door is normally locked(DORMA TV 200, TV 500).Operation of the emergencypushbutton in the DORMA TLdoor terminal causes thelocking mechanism to bede-energized and released,and also the deadbolt andlatch of the DORMA SVP 200emergency exit motor lock tobe withdrawn and enabledrespectively. At the same timethe system emits an alarmand the DORMA ED 200receives an opening signal.Authorized users may unlockthe door with the DORMA TLkey switch/button or viaDORMA access controlsystems. If the DORMA RMsmoke detector responds,the DORMA TV electricallocking device is unlocked,the DORMA SVP 2000emergency exit motor lockwith self-locking actionis locked and the DORMAED 200 is de-energized.These actions ensure that the fire protection characteristics of the doorare maintained.
If activated from a centralcontrol position, the TV electrical locking device andthe SVP 2000 emergencyexit motor lock are unlockedand the ED 200 opens thedoor. MPA (German MaterialTesting Authority) VdS (insurance) approval certifi-cates for use in emergencyexits and escape routes havebeen issued for this system.
The following componentsare required: 2 DORMA ED 200 swing
door operator2 TL-G TMS door terminal
with TL-S TMS controlboard
2 TV 200, TV 200 DCWelectrical locking device
2 SVP 2000 emergency exitmotor lock with self-locking action
2 SVP-S DCW motor lockcontrol module
2 SVP-A … motor lock cable 2 Flush-mounted cable loop
KÜ ST 32 DCW key button2 DCW junction box2 I/O DCW module
Insurance lock
When closed, the door islocked by the DORMA SVP 2000 emergency exitmotor lock with self-lockingaction (insurance lock). The door can be opened andclosed from the inside at anytime, with unlocking actionof the DORMA SVP 2000and the delayed activationof the DORMA ED 200 beinginitiated either manually or by active detectors asrequired. Activation controlfrom a central position isalso possible. Authorizedusers may be granted accessfrom the outside. Once thedoor is closed, the insurancelock is reinstated fully automatically as the DORMASVP 2000 automaticallythrows the bolt after eachclosing cycle. The DORMA
SVP-S22 motor lock controlmodule is installed underthe extended cover of the ED 200 for activation controlof the DORMA SVP 2000.
The following componentsare required: 2 ED 200 swing door
operator2 SVP 2000 emergency
exit motor lock with self-locking action
2 SVP-S22 DCW motor lockcontrol module
2 SM 24 special module forstabilized power supply
2 SVP-A … motor lock cable 2 Concealed/flush-mounted
cable loop KÜ2 Activator
24
Reversing
The DORMA IRS-2 safetysensor is a monitoringmodule designed to safe-guard the sweep range of automatic swing doors. It can be mounted travellingon the hinge (pull) andopposite hinge (push) side ofthe door. If mounted on theopposite hinge (push) side,the DORMA IRS-2 safetysensor acts as an activatorto open the door in the closerange of the door. As soonas an object is located on
this side of the door, the dooris reopened automaticallydue to a new activatingimpulse given by the safetysensor. In case that the safetysensor on the hinge (pull)side is activated, the auto-matic opening action of thedoor is stopped in order toavoid collisions with objectsin the scanning range of theIRS-2 safety sensor. Thetechnical principle of thesafety sensor ensures thatpeople and objects are
detected at the same time.The scanning range of theIRS-2 is adjustable andinfrared light is used tosafeguard the driving phaseof the door. As an activeinfrared sensor, the IRS-2detects all static and movingobjects, e. g. items or people, within its scanningrange. The IRS-2 is availablein different lengths and with a variable number ofinfrared sensors. Dependingon the door width, DORMA
recommends to select thelongest-possible IRS-2safety sensor variant with a maximum number of integrated infrared sensorsas the scanning range growsin line with the number of infrared sensors. Thisensures the maximum safetyof the swing door.
DORMA ED 200 DORMA IRS-2 infraredsafety sensor
2 Available in the followinglengths: 330, 700, 900and 1200 mm
2 Suitable for LH (ISO 6)and RH (ISO 5) doors
2 Mounting on the hinge(pull) and opposite hinge(push) side
2 Suitable as openingactivator for automaticdoors
2 Ideal activating sensor forconfined situations due toits small scanning range
2 May serve as travellingopening protection forswing doors
2 Monitoring of crushing-and shearing edges
Benefits and features
Number of integrated Length ofsafety sensors safety sensor
IRS-2-33 1 1330 mm
IRS-2-70 1 1700 mm
IRS-2-90 2 1900 mm
IRS-2-120/2 2 1200 mm
IRS-2-120/3 3 1200 mm
IRS-2 infrared safety sensor variants
0 1 m 2 m
1 m
2 m
max. 2500 m
m30°
Scanning range
42
37
Cross section
SafetyDORMA IRS-2 Reversal STOP
25
30 30 4,2
23
,5
44
38
91
38
85
38
85
15 x 0,7° = 10,5°
115°
IRS-2 mounting dimensions
Mounting on the oppositehinge (push) side with standard arm
Mounting on the oppositehinge (push) side with slide channel
Mounting on the hinge(pull) side with slide channel
Application and benefitsThe ED 200 is also availablewith the electronic controlunit Push&Go, which caneasily be retrofitted as anaccessory. Just push slightlyand the door leaf opensautomatically, thus evenheavy doors can be operatedwithout any effort. Inhibitionsnot least older people mighthave when it comes tomodern technology are beingremoved.In contrast to radar or infra-red-controlled door systems,the comfort version ensuresthat heavy-used doors andentrances are not openedunnecessarily. Push&Go isthe appropriate alternativefor locations with insufficient
space for radar or pushbuttonactivation. Where fire doorsare retrofitted with Push&Go,the fail-safe lock need notbe exchanged. An additionalincremental encoder ensuresthat the Push&Go systemcan be activated from anyopening angle. Furthermore,the sensitivity of the systemis adjustable in 15 levels. If the door hits an obstacleduring its closing action, itwill be reopened immedia-tely. As no additional wiringis required, Push&Go is the economical alternativeto a radar-controlled system.
2 In contrast to radar orinfrared-operated doorsystems, the ED 200Push&Go prevents heavy-used doors from beingopened unnecessarily
2 Ideal solution for locationswith insufficient space forradar or pushbuttonactivation
2 Even heavy doors can beopened manually with thesupport of Push&Go
2 It minimizes the inhibitionthresholds of older people
2 Activation from any opening angle
2 The ED 200 (with controlboard A and B) can easilybe retrofitted with Push&Go
2 Adjustable sensitivity (15 levels)
2 Safety function: the opening action is reversedas soon as the door hits anobstacle
Electronic control unit Push&Go
26
DORMA ED 200 System accessories
PG-D1
Mounting position for turn switch
30
46
80
80
31
AP
= 4
7,5
UP
= 7
,5
30
Program switchWhen combining the system with a program switch out of theDORMA accessory range, the automatic door system evenmeets individual requirements and offers easy handling. These program switches are available in various designshave been conceived for all kinds of demands. Furthermore they offer various options, from a mechanical toa full-electronic version alternatively also lockable via Europrofile half-cylinder or in a full-electronic way via code.
2 Up to 4 different functions: Off, Automatic, Exit Only,Permanent Open
2 Electronic program switches in System 55 design to copewith the highest aesthetic demands
PG-D1 program switch4-position, aluminium,white, for control unit A and B, flush-mounted, 80 x 80 mm, Gira S-Color
Order No. 19135404150
PG-D3
Mounting position for turn switch
30
46
80
80
AP
= 4
7,5
36
UP
= 7
,5
PG-D3 program switch4-position, lockable, aluminium, white, controlunit B, flush-mounted,80 x 80 mm, Gira S-Color
Order No. 19135604150
27
PG-D4
box for surface mounting for PG-D4for mechanical programswitch, 100 x 80 x 65 mmstandard frame, white
Order No. 19142201170
EPS-D
EPS-D full-electronic program switchin System 55 design, 4-position, lockable via codeor additional TL-ST S55 keyswitch, membrane keypad,aluminium coloured, white,flush-mounted, 80 x 80 mm
Order No. 16557001150
PG-D4
Flush-mounting box 97x75x6580
10
5
97
65
PG-D4 program switch4-position, lockable via Euro profile half-cylinder,white, flush-mounting, 105 x 80 x 65 mm,box for surface-mounting:19142201170
Order No. 19141801170
2 4
1 3
80
80
13 10
R 30
19PUSH OUT
77
10
0
65
Thread M3
83
,5
15
15
21,5 PUSH OUT19
28
Pushbuttons
Pushbutton
PushbuttonSingle-pole changeovercontact, standard frame,white, flush-mounting,System 55
Order No. 19144701170808
0
12,5
Large-sized pushbutton (elbow)
Large-sized pushbutton(elbow)flush-mounting/surface-mounting, electrical, silveranodic coating CO, 304 x 80 mm
Order No. 90410015
Key switch
Key switch KT 3-11 NO contact, with Europrofile half-cylinder (can bereplaced by any half-cylinderof a master-key system), youcan only withdraw the keywhen it is in zero position,aluminium, metal, 75 x 75 x 60 mmKT 3-1 flush-mountingOrder No. 05054531332
KT 3-1 surface mountingOrder No. 05054631332
Key switch KT 8Lettering “Auf, Zu”, 2 NOcontacts, with Euro profilehalf-cylinder can be replacedby any half-cylinder of amaster-key system), you canonly withdraw the key whenit is in zero position, aluminium, metal, 75 x 75 x 60 mmKT 8 flush-mountingOrder No. 05054831332
KT 8 surface mountingOrder No. 05054931332
Flush-mounting version
6050
l 5
975
75
KT 3-1 Flush-/Surfacemounting
Surface-mounting version
17 9
401010
19
PG 13,5
45
9
KT 8 Flush-/Surfacemounting
40
57
80
30
4
25
4
27
4
402
0
30
6,5
DORMA ED 200 System accessories
29
Large-sized pushbutton (elbow)
Large-sized pushbutton(elbow)surface-mounting, extra-flatdesign, synthetic material,grey, 209 x 79 x 17 mm
Order No. 05080231332
79
20
9
40
16
9
59
,5
17 4,8
Large-sized pushbuttons
Large-sized pushbuttonwith box for flush-mounting,without switch pad, incl.switch, 224 x 82 mmOrder No. 05095531332
Large-sized pushbuttonwith box for surface-mounting,without switch pad, incl. 2 switches, paint sprayed foraluminium effect, 224 x 82 x 44 mmOrder No. 05095231332
Switch padaluminium, suitable forflush-/surface-mounting,214 x 70 mmOrder No. 05095431332
Switch padaluminium, suitable forflush-/surface-mounting,214 x 70 mm, with inscrip-tion reading “Tür auf”Order No. 05095331332
82
22
4
39,5
11
71
82
22
4
44
Flush-mounted design
Surface-mounted design
CT 4/1 code keypad as control for locking devices (keypad and electronic module have to be combined)
MTB 4/1 metal keypadto enter the activation code(to open the door) and forprogramming purposes, surface-mounting, 75 x 75 x 11.5 mmOrder No. 05079331332
EB 4/1Electronic module, incl. 2 mconnection cable, plasticcover, black, surface-mountingOrder No. 05063431332
The code keypad does not require optional software for simple access authorizations. The metal keypad is waterproofand protected against manipulation thus it is also suitablefor installation on the outside of a building. The four- or six-digit code can be changed at the keypad via Plug & Play.The respective control unit is installed in the protected areaand can be connected to all DORMA operators.Surface-mounting, 230 V/50 Hz, 1.5 V A, 1 x UM potential-free relay contact 8 A, 250 V, connections: max. 2.5 mm, 75 x 75 x 11.5 mm.
30
DORMA ED 200 System accessoires
Radio transmitters and transponders
Radio remote control system
DORMA RC-TLarge-sized pushbuttons
DORMA RC-TLarge-sized pushbutton with integrated radio transmitter,small pushbutton and RC-T radio remote control includingbattery (product life: approx. 1 year with 60 activations/day),without switch pad, 2 channels, 433.92 MHz, with box forsurface-mounting 224 x 82 x 44 mmOrder No. 16562201175
Switch pad, aluminium, suitable for flush-/surface-mounting,214 x 70 mmOrder No. 05095431332
Switch pad with inscription reading “Tür auf”, aluminium,suitable for flush-/surface-mounting, 214 x 70 mmOrder No. 05095331332
DORMA RC-T HandHeldhand-held transmitter, incl. battery (product life: approx. 1 year with 60 activations/day), 4 buttons that can be assigned individually, 2 channels, frequency: 433.92 MHz,plastic, blackOrder No. 1656210117
The RC-R radio receiver can be combined with all DORMAoperators. Apart from the handy RC-T HandHeld radio remote control, also large-sized pushbuttons are available.Thanks to its individual code, the system can also beapplied as a simple access control system. This is realizedby storing the code of the radio remote control in the radioreceiver via Plug&Play and allows you to allocate differentaccess authorizations. Furthermore this system is especiallysuitable for upgrades as no wiring for the pushbuttons isrequired. Coverage: up to 20 m.DORMA RC-RReceiver module including adaptor for installation in ED 200, CD 400, CD 80 and PORTEO 24 V DC, 1 channel,self-learning – also for several remote controls, 24 V DC,max 100 mA, frequency: 433.92 MHzOrder No. 16562301170
DORMA RC-THandHeldHand-heldtransmitter
DORMA AutoSwitch transponder
The active transponder system: This system automaticallysends a pulse to the control unit when entering the detection range (which amounts to approx. 2.5 m) and is especially suitable for areas where a manual operation has to be excluded. Thanks to its coverage, it is the adequate access controlsystem for doors used by wheelchair drivers.
DORMA AutoSwitchReceiver/control unit, surface-mounting, whiteOrder No. 16571101175
Programming-(Transponder-) key, yellowOrder No. 16571201175
Standard-(Transponder-) key, blueOrder No. 16571301175
31
Radar motion detectors
Eagle 1Direction recognition, blackOrder No. 16503101170
whiteOrder No. 16503103170
silverOrder No. 16503102170
MerkurCross traffic suppressionwith direction recognition,blackOrder No. 16532201170
Radar motion detectors with direction recognition
Radar motion detectors detect approaching people at anearly stage and emit an activation (opening) signal for thedoor operator. Radar motion detectors only respond to movements. Thanks to their various adjustment options, alsodifficult installations can be realised.
3 mm
8 mmCable entry
80
120
50
100
34
26
50
Eagle black Eagle silverEagle white
57
168
150
82
1
Merkur
32
DORMA ED 200 System accessoires
Active infrared safety sensors
Cable entry = 165
L
8
30 3038
23
,6
4,2
42
IRS-2-33 with 1 sensor, length: 330 mmPower supply: 24 V DC, power consumption: 100 mA, silver (E 6/C O) 16521701150Maximum load current: 0.2 A at 48 V DC, (traffic white) RAL 9016 16521704150Installation height: min. 0.5 m / max. 2.5 m further RAL 16521705150
IRS-2-70 with 1 sensor, length: 700 mmPower supply: 24 V DC, power consumption: 100 mA, silver (E 6/C O) 16521706150Maximum load current: 0.2 A at 48 V DC, (traffic white) RAL 9016 16521709150Installation height: min. 0.5 m / max. 2.5 m further RAL 16521710150
IRS-2-90 with 2 sensors, length: 900 mmPower supply: 24 V DC, power consumption: 200 mA, silver (E 6/C O) 16521711150Maximum load current: 0.2 A at 48 V DC, (traffic white) RAL 9016 16521714150Installation height: min. 0.5 m / max. 2.5 m further RAL 16521715150
IRS-2-120/2 with 2 sensors, length: 1200 mmPower supply: 24 V DC, power consumption: 200 mA, silver (E 6/C O) 16521716150Maximum load current: 0.2 A at 48 V DC, (traffic white) RAL 9016 16521719150Installation height: min. 0.5 m / max. 2.5 m further RAL 16521720150
IRS-2-120/3 with 3 sensors, length: 1200 mmPower supply: 24 V DC, power consumption: 300 mA, silver (E 6/C O) 16521721150Maximum load current: 0.2 A at 48 V DC, (traffic white) RAL 9016 16521724150Installation height: min. 0.5 m / max. 2.5 m further RAL 16521725150
IRS-2 safety sensors
IRS-2 active infrared safety sensor Colour Order No.
33
Power transit device and cable loops
Power transit device type 10305
Power transit device Type 10305two-pole, to transfer electric current from the door frame tothe door leaf while the door is closed.
Order No. 05045231332
KÜ 300 cable loopFlexible metal loop for protection of cables between door anddoor frame, max. cable diameter: 5 mm, Length: 300 mm
Order No. 05045331332
KÜ 600 cable loopFlexible metal loop for protection of cables between door anddoor frame, max. cable diameter: 5 mm, Length: 600 mm
Order No. 05101933332
Robust stainless steel spiral to protect flexible cables with adiameter of up to 8 mm between movable elements.
KS 155 cable loopCable spiral for door hinges of up to 18 mm, to cover opening angles of up to 110°, variable length: 155 mm, Installation dimensions (W x H x D): approx. 17 x 255 x 15 mm
Order No. 15817000
KS 370 cable loopCable spiral for door hinges of up to 36 mm, to cover opening angles of up to 180°, variable length: 370 mm,Installation dimensions (W x H x D): approx. 17 x 470 x 15 mm
Order No. 15819000
Robust stainless steel spiral with recess box for flexibleconnection cables, for cables with a diameter of up to 8 mm. Ensuring a pinch-free and sabotage-proof connectionbetween the leaf and frame of doors and windows.
KÜ 260 cable loopfor door hinges of up to 18 mm, to cover opening angles ofup to 110°, variable length: 155 mm, installation dimensionsof recess box (W x H x D): approx. 24 x 260 x 17 mm
Order No. 15811000
KÜ 480 cable loopfor door hinges of up to 36 mm, to cover opening angles ofup to 180°, variable length: 370 mm, installation dimensionsof recess box (W x H x D): approx. 24 x 480 x 17 mm
Order No. 15813000
71
58
5,3
5,3
41
13 175
45
As linking element between the door leaf and the doorframe, the cable loop is of special importance. Like all otherDORMA products, these cable loops offer solidity and long product life. Therefore DORMA cable loops have anespecially robust metal spiral, which ensures, together withthe recess box, the optimum protection of the contained flexible connection cables.
KÜ 300/600
10
300
30
5
4,220,5
30
KS 155/370
16
BA C
A-B
Spring loose, not yet secured
Spring secured by bending the shim
C-D
15
5
D
0,5
KÜ 260/480
Cable loops
34
The DORMA KÜ-CD cable loop offers the ideal solution forthe door leaf fixing options of the CD operator.
The combination of
– Junction box (1)
– Junction box accessories (2)
– Cable loop (inner diameter 12 mm) (3)
– Cable loop (inner diameter 20 mm) (4)
– Adapter-unit (5)
enables elegant concealment of all the requisite cablingconnecting the operator to the supply.
1
2
5
3
4
5
2
Junction box (1)for cable loop (internal diameter: 12 mm or 200 mm), white, includingaccessories (2)
Order No. 5163333332
cable loop (3) 600 mm,internal diameter: 12 mm,silver
Order No. 5163433332
cable loop (4) 600 mm,internal diameter: 20 mm,silver, incl. fixing elements
Order No. 5163533332
Adaptor unit (5)to conceal the cabling on itsway into the operator, combinable with both cableloops
silverOrder No. 5163133332
RAL 9016 (traffic white)Order No. 5163233332
KÜ-CD cable loop for door-leaf mounted DORMA swing door operators
DORMA ED 200 System accessoires
35
In order to assure unlimited safety to all visitors of a building,every door system within this building has to remain fullyfunctional even in the event of a power failure. This is ensured by the DORMA MT 700 USV emergency power supply unit. Depending on its equipment, this unit canmaintain the function of an operator for up to one hour.During this time, the whole door system is provided withemergency power so that there remains sufficient time for countermeasures and securing the building.USV MT 700 VA emergency power supply unit integrated in 230-V power supply lineDimensions: 160 x 120 x 360 mm (W x H x D)
Order No. 05094531332
SM 202 special modulecompletely packed (suitable for installation in end cap)
Order No. 18806701175
The red-green display indicated the status of the doorsystem. The extravagant, semicircular designer signal lampis made of acryl, manufactured according to the latest LEDtechnology and has a high-grade LED display (24 V, brilliancyaccording to DIN VDE (German association of engineers)0834, part 1). The light signals are visible from both sidesand the front even from a large distance. Its display is resistant against almost all disinfectants and cleaning agents.Light signal, 24 V DC, LED-display red, green, white.
Order No. 05111631332
Further accessories
Red-green display
Emergency power supply unit
SM 202 special module
WN
05
1 5
78
51
53
2,
08
/08
, G
B,
xx.
DD
. xx
/08
·
Sub
ject
to
chan
ge w
itho
ut n
otic
e
www.dorma.com
Door Control
Automatic
Glass Fittings andAccessories
Security/Time andAccess (STA)
Movable Walls
Automatic Division worldwideDORMA GmbH + Co. KGDORMA Platz 1D-58256 EnnepetalPhone +49 2333/793-0Fax +49 2333/793-495
Region AustralasiaAUS, NZ
AustraliaDORMA Automatics Pty. Ltd.Phone +61 3 97964111www.dorma.com.au
New ZealandDORMA Automatics Pty. Ltd.Phone +61 3 97964111www.dorma.com.au
Region Central EuropeD, NL, B, LX, CH
GermanyAutomatic DPhone +49 2333 793-0www.dorma.de
NetherlandsDORMA van Duin Nederland BVPhone +31 488 418 100www.dorma.nl
BelgiumDORMA foquin N.V./S.A.Phone +32 50 312849www.dorma.be
LuxembourgLuxembourg Subsidiary AutomaticPhone +49 2333 793-216www.dorma.de
SwitzerlandDORMA Schweiz AGPhone +41 71 8864646www.dorma.ch
Region Emerging MarketsP, RUS, UA, BG, GR, TR, IND, IL, RSA
PolandDORMA Polska Sp. z o.o.Phone +48 22 736-59-00www.dorma.pl
RussiaRepresentative Office in RussiaPhone +7 095 2581225www.dorma.com
UkraineDORMA Representation UkrainePhone +380 44 2443897www.dorma.com
BulgariaDORMA BulgariaPhone +359 2 9714 904www.dorma.com
GreeceDORMA Representation GreecePhone: +30 21 09944388www.dorma.com
TurkeyDORMA Kapi Kontrolleri Ltd. StiPhone: +90 216 3600056www.dorma.com
IndiaDORMA Door Controls IndiaPhone +91 442 8585097www.dorma.com
IsraelDORMA GmbH + Co. KGPhone +49 2333 793-0www.dorma.com
South AfricaDORMA Door Controls (Pty.) LtdPhone +27 11 8300280www.dorma.com
Region Far EastSGP, HK, VRC, RC, MAL, RI, RP,ROK, VN, J
SingaporeDORMA Far East Pte. Ltd.No. 31 Gul LanePhone +65 62 68 76 33www.dorma.com.sg
Hong KongDORMA Door Controls Pte. Ltd.Phone +852 25034632www.dorma.com.sg
ChinaDORMA Door Controls (Suzhou)Co. Ltd.Phone +86 512 676 12481www.dorma.com.sg
TaiwanDORMA Door Controls Pte. Ltd.Phone +886 2 9182987www.dorma.com.sg
MalaysiaDORMA Emerald Entrance SystemsPte LtdPhone +65 459 5733www.dorma.com.sg
IndonesiaDORMA Emerald Entrance SystemsPte LtdPhone +65 459 5733www.dorma.com.sg
South KoreaDORMA Emerald Entrance SystemsPte LtdPhone +65 459 5733www.dorma.com.sg
PhilippinesDORMA Door Controls Pte. Ltd.Phone +632 893 40778www.dorma.com.sg
VietnamDORMA Emerald Entrance SystemsPte LtdPhone +65 459 5733www.dorma.com.sg
JapanDORMA Emerald Entrance SystemsPte LtdPhone +65 459 5733www.dorma.com.sg
Region FranceFFranceDORMA Accueil S. A. S.Phone +33 4 79348924www.dorma.fr
Region GulfSaudi Arabia, Bahrain, Kuwait,Egypt, Syria, Jordan, Lebanon, IranDORMA ARABIA Automatic Doors Ltd.Kingdom of Saudi ArabiaPhone +966 3 847 2394www.dorma.com
United Arab Emirates, Oman, QatarDORMA Middle East LLCDubaiPhone +971 4 282 4424www.dorma.com
Region North AmericaUSA, CDN, MEX
USADORMA Automatics Inc.Phone +1 301 390-3600www.dorma-usa.com
CanadaDORMA Door ControlsPhone +1 905 6701281www.dorma.com
MexicoDORMA México, S. de R.L. de C.V.Phone +52 55 5272 6937www.dorma.com
Region ScanbaltN, S, DK, FIN, LV, EST, LT
NorwayDORMA Norge A/SPhone +47 23 176800www.dorma.no
SwedenDORMA Sverige ABPhone +46 31 289520www.dorma.se
DenmarkDORMA Danmark A/SPhone +45 44 543000www.dorma.dk
FinlandDORMA Finland OyPhone +358 9 8789130www.dorma.fi
LatviaDORMA Finland OyPhone +358 9 8789130www.dorma.fi
EstoniaDORMA Representation EstoniaPhone +372 6707064www.dorma.com
LithuaniaDORMA Norge ASPhone +47 23 176800www.dorma.com
Region South AmericaBR, RA
BrazilDORMA Sistemas de ControlesPhone +55 11 41913244www.dorma.com.br
ArgentinaDORMA Sistemas deControles para Portas LtdaPhone +54 11 45051032www.dorma.com
Region South-East EuropeA, H, CZ, CS, HR, SLO, RO
AustriaDORMA AKS Automatic GmbHPhone +43 6225 8636-0www.dorma.at
HungaryDORMA AKS Automatic GmbHPhone +36 1 2065127 or 2058058www.dorma.com
Czech RepublikDORMA dverní technika CR, s.r.o.Phone +420 2 671321-78 or -79www.dorma.com
SlovakiaDORMA Slovensko spol. s.r.o.Phone +421 2 50221 283www.dorma.com
CroatiaDORMA UREDPhone +385 1 3498 422www.dorma.com
SloveniaDORMA Representation SloveniaPhone +386 2 5 30 20 10www.dorma.com
RomaniaDORMA Romania S.R.L. Phone +40 31 806 91 60www.dorma.com
Region South EuropeI, E, P
ItalyDORMA Italiana S.r.l.Phone: +39 039 244031www.dorma.it
SpainDORMA Ibérica, S.A.Phone +34 91 8757851www.dorma.es
PortugalDORMA Portugal para Portas, Lda.Phone +351 252 860 490www.dorma.com
Region UK/IrelandGB, IRL
Great BritainDORMA UK LimitedPhone +44 1462 477600www.dorma-uk.co.uk
IrelandDORMA Ireland LimitedPhone +353 1 295 8280www.dorma.com
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 150 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.00000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages false /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 300 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.00000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False
/CreateJDFFile false /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure false /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles false /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /DocumentCMYK /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /UseDocumentProfile /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice