Software Upgrade ProcedureMarconi OMS 846 R1.5
UPGRADE INSTRUCTIONS
1/153 72-CRA 119 0511/15 Uen C
Copyright
Ericsson AB 2011. All rights reserved. No part of this document may bereproduced in any form without the written permission of the copyright owner.
Disclaimer
The contents of this document are subject to revision without notice due tocontinued progress in methodology, design and manufacturing. Ericsson shallhave no liability for any error or damage of any kind resulting from the useof this document.
1/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Contents
Contents
1 Introduction 11.1 General Important Information 1
2 Software Upgrade in CRAFT 52.1 Preparations 52.2 Upgrade Procedure 62.3 Verification 82.4 Rollback Procedure 8
3 Software Upgrade in OSS 113.1 Prerequisites 113.2 Upgrade Procedure 12
Reference List 17
1/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Software Upgrade Procedure
1/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Introduction
1 Introduction
The purpose of this document is to describe the upgrade procedure for theOMS 846 Release 1.5.
1.1 General Important InformationThis section provides general important information of upgrading procedures.
1.1.1 Terminology
Terminologies for the OMS 846 system upgrading used in this document aregiven as follows:
NR OMS 846 device network release which contains the two items below.
Software System Controller Software
Firmware Module Firmware
Each of them is a collections of loadable items running in the OMS 846 R1.5.
1.1.2 Traffic Interruption
No traffic will be interrupted while downloading OMS 846 NR without restartingthe Network Element (NE).
No traffic will be interrupted while downloading OMS 846 software.
All traffic will be interrupted while downloading OMS 846 firmware.
Approximately 90 seconds traffic interruption can be expected for mostupgrades.
1.1.3 Active and Inactive Banks Consistencies
The OMS 846 supports both active and inactive bank. It is recommended tokeep consistent versions of NR, software, or firmware for both banks. So therepetitive upgrade operation procedures are needed for both the active andinactive banks.
11/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Software Upgrade Procedure
1.1.4 Network Release Content
Table 1 shows network release file and patch information for all the OMS 800series software upgrade.
Table 1 OMS 800 Series Software Upgrade Files
UpgradeSuit
Suit FileName
ApplicableVersion
FileType
File Name
NR 1_19089-CXP9013872_13END.zipOMS 846
R1.3 Patch 2_19089-CXP9013872_13ENC.zip
NR 1_19089-CXP9013871_22END.zipOMS 860
R2.2 Patch 2_19089-CXP9013871_22ENC.zip
OMS 870R3.2
NR 19089-CXP9014402_32ENE.zip
OMS 800R3.2
LZY 2144375/32 R1BSW CD
OMS 800Craft R1.1
LCTInstall
1_19003-CXP9015678_11END.exe
NR 1_19089-CXP9013872_14ENC.zipOMS 846
R1.4 Patch 2_19089-CXP9013872_14ENC.zip
NR 1_19089-CXP9013871_23ENC.zipOMS 860
R2.3 Patch 2_19089-CXP9013871_23ENC.zip
OMS 870R3.3
NR 19089-CXP9014402_33ENC.zip
OMS 800R3.3
LZY 2144375/33 R1CSW CD
OMS 800Craft R1.2
LCTInstall
19003-CXP9015678_12ENC.exe
2 1/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Introduction
UpgradeSuit
Suit FileName
ApplicableVersion
FileType
File Name
NR 1_19089-CXP9013872_15ENC.zip
OMS 846R1.5
Patch 2_19089-CXP9013872_15ENC.zip
NR 1_19089-CXP9013871_24ENC.zip
OMS 860R2.4
Patch 2_19089-CXP9013871_24ENC.zip
OMS 870R3.4
NR 19089-CXP9014402_34ENC.zip
OMS 800R3.4
LZY 2144375/34 R1ASW CD
OMS 800Craft R1.3
LCTInstall
19003-CXP9015678_13ENC.exe
The Table 2 shows network release and patch files available in CD.
Table 2 OMS 846 Network Release Files
Files Description Location1_19089-CXP9013872_15ENC.zip
OMS846_NR OMS800 R3.4 LCT andESW CD
2_19089-CXP9013872_15ENC.zip
OMS846_NR_patch_fromR1.1toR1.5
OMS800 R3.4 LCT andESW CD
The Table 3 shows the network releases contained in the file 1_19089-CXP9013872_15ENC.zip and the patch 2_19089-CXP9013872_15ENC.zip, whichare stored in OMS800 R3.4 LCT and ESW CD. Items in BOLD are new inthis release (compared to R.1.4, R-state R1F). See the file package.xml forthe code of each item.
Table 3 Network Release Content
Network Release definition filepackage.xmlSYSTEM SWMain Card FW
Note: The file 2_19089-CXP9013872_15ENC.zip is required when upgradingthe system from a version earlier than R1.3 to R1.5.There is no patch required when upgrading the system from OMS 846R1.3 or R1.4 to R1.5.
31/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Software Upgrade Procedure
4 1/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Software Upgrade in CRAFT
2 Software Upgrade in CRAFT
This chapter describes how to upgrade the software by using an OMS 800CRAFT terminal.
2.1 PreparationsThis section presents the preparations needed for a successful completionof the procedures in this instruction.
2.1.1 Required Tools and Access Information
The following tools and access information is required:
A PC with OMS 800 Craft installed.
Note: OMS 800 CRAFT R1.3 is the minimum required for operating thisNR of OMS 846 R1.5. For more information about how to installand upgrade CRAFT, refer to OMS 800 CRAFT 1.3 User Guide,Reference [2].
A LAN cable for local access to a Network Element (NE). The IP address of the NE.
The password for the administrator.
2.1.2 Additional Preparations
Consider the following additional preparations:
Relevant network release files and patches listed in Table 2 are available.
Ensure that the NE is in a suitable state for upgrading by checking thefollowing status:
NE Current Version
Bank Status and Versions
Network Release Validity
Backup the current CDB file.
Note: Refer to OMS 800 CRAFT 1.3 User Guide, Reference [2] forinstructions.
51/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Software Upgrade Procedure
2.2 Upgrade ProcedureThis section describes the upgrade procedures.
For how to upgrade the system from a release earlier than OMS 846 R1.3,see Section 2.2.1 on page 6.
For how to upgrade the system from OMS 846 R1.3 or R1.4, see Section2.2.2 on page 6.
2.2.1 Upgrade from a Release Earlier than R1.3
When upgrading from a release earlier than OMS 846 R1.3, perform the stepsbelow:
1. Download the patch 2_19089-CXP9013872_14ENC.zip.
2. Download the network release file 1_19089-CXP9013872_14ENC.zip.
2.2.2 Upgrade from OMS 846 R1.3 or R1.4 to R1.5
To unpack and install the packages mentioned in Table 3, perform the followingsteps:
1. Launch OMS 800 CRAFT and logon as an administrator user.
2. On the Equipment menu, click NE Maintenance. . . . This opens theNE Maintenance window.
3. Click the TFTP Server in the Information panel of the left navigation bar.
4. Ensure the Enabled check box is checked and remain other settings asdefault.Note: The value of the Host can only be set as 0.0.0.0 when the computeris connected to the device directly. In this case, 0.0.0.0 represents thecomputer's IP address. Otherwise, the Host value should be set accordingto the network address.
5. Click Device in the Network Release panel of the left navigation bar.
6. On the toolbar, click Download to open the Download wizard window,then click Next.
7. Click Add file to repository to open the Package Installer window, thenclick Next.
8. Click Browser to select the package file that mentioned in Section 1.1.4on page 2.
9. Click Next, and then click Finish.
10. When the package installation process is finished, click Close to close thePackage Installer window.
6 1/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Software Upgrade in CRAFT
11. In the Download wizard window, select the desired network release fromthe repository list and click Next.
12. Select the Restart NE Time from the drop down list.
Note: The selected time will overwrite the scheduled restart time thatwas set before.
13. Click Next, and then click Finish.You may close the Download wizard window and view the downloadprogress in the NE Maintenance window.In the OMS 800 Craft window, the TFTP events during the network releasedownload are shown in the Event Trace page of the Notification Listpanel.
Note: If a scheduled restart is selected, the status panel in the NEMaintenance window displays the restart time after the downloadis finished. This information is kept until the NE restart completes.
14. If a scheduled NE restart is initiated, the "Connection Lost" is reported.When the NE restart finishes, the "Equipment Reconnected" is reported.Click OK when the massage boxes show.
71/153 72-CRA 119 0511/15 Uen C | 2011-09-29
Software Upgrade Procedure
2.3 VerificationTo verify the upgrade is successful, perform the following steps:
1 In the OMS 800 Craft window, click the device node in the ManagementTree panel.
2 Check the value of the Network Release Validity. If the upgrade issuccessful, the value is OK.
Note: If the current configuration is not at NR level, click the link ofNetwork Release Validation to view the details.
2.4 Rollback ProcedureWhen rollback from OMS 846 R1.4 to a previous release, following the stepsbelow:
1. Backup the current CDB file, Refer to OMS 800 CRAFT 1.3 User Guide,Reference [2]