11
SUZLON ENERGY INNOVATOR: SUZLON DATE:3/11/12 TEAM DCSMAT RESHMA VINEETH ARUN ARAVIND

Suzlon one earth

Embed Size (px)

Citation preview

Page 1: Suzlon one earth

SUZLON ENERGYINNOVATOR: SUZLON

DATE:3/11/12

TEAM DCSMATRESHMAVINEETH

ARUNARAVIND

Page 2: Suzlon one earth

SUZLON ENERGY

• FOUNDED IN 1995 BY TULSI TANTI

• THE SUZLON GROUP IS RANKED AS THE WORLD’S FIFTH LARGEST WIND TURBINE SUPPLIER

• SPREAD EXTENDS ACROSS ASIA, AUSTRALIA, EUROPE, AFRICA AND NORTH AND SOUTH AMERICA

• OPERATIONS ACROSS 33 COUNTRIES AND A WORKFORCE OF OVER 13,000.

Page 3: Suzlon one earth

PRODUCT PORTFOLIO

Page 4: Suzlon one earth

GLOBAL WIND ENERGY TRENDS• TODAY, ABOUT 75 COUNTRIES WORLDWIDE HAVE

DEVELOPED COMMERCIAL WIND FARMS.

• GLOBALLY, 41,000 MW OF WIND POWER CAME ONLINE IN 2011, RAISING BY 21% .

• THE TOTAL INSTALLED GLOBAL CAPACITY TO 238,351 MW

• THE GLOBAL WIND ENERGY COUNCIL PREDICTS AVERAGE INTERNATIONAL MARKET GROWTH RATES OF ABOUT 8% PER YEAR FOR THE NEXT FIVE YEARS, WITH GLOBAL INSTALLED WIND CAPACITY REACHING.

Page 5: Suzlon one earth

SUZLON ONE EARTH • CARBON NEUTRAL (THROUGH ON SITE + OFF SITE ENERGY)

– –ZERO NET ENERGY FOR LIGHTING (THROUGH ON-SITE GENERATION)– –PV SYSTEMS INTEGRATED IN DESIGN– –MICRO WIND (TO BE EVALUATED)– –BIOMASS (KITCHEN WASTE + STP OUTPUT + LANDSCAPE WASTE)

• SYSTEM FLEXIBILITY OF VARIABLE REFRIGERANT VOLUME SYSTEM (HVAC)– THE INDOOR UNIT'S COOLING OPERATION CAN BE CONTROLLED TO

MAINTAIN DESIRED TEMPERATURE IN ANY LOCATION IN THE PREMISES ACCORDING TO END USER'S NEEDS AND PREFERENCES.

• OPTIMIZE BUILDING DESIGN TO REDUCE THE CONVENTIONAL ENERGY DEMAND

• OPTIMIZE THE ENERGY PERFORMANCE OF THE BUILDING WITHIN SPECIFIED COMFORT LIMITS

• UTILIZATION OF FLY ASH IN THE BUILDING STRUCTURE• REDUCE VOLUME, WEIGHT, AND TIME OF CONSTRUCTION BY ADOPTING AN

EFFICIENT TECHNOLOGY• USE LOW-ENERGY MATERIAL IN THE INTERIORS

*Slide content Courtesy “ Case Study of Kavitha Jain

Page 6: Suzlon one earth

SUZLON ONE EARTHRENEWABLE ENERGY UTILIZATIONBIPV SOLAR PANEL

ESTIMATED ENERGY P.A =20,000 KWH

ESTIMATED ENERGY (18 WIND MILL + 243 SOLAR PANEL) P.A =2, 30,000 KWH

Page 7: Suzlon one earth

RENEWABLE-ENERGY-BASED HOT WATER SYSTEM

100% OF HOT WATER REQUIREMENT IS MET BY THE SOLAR HOT WATER SYSTEM

Page 8: Suzlon one earth

FIVE FORCE ANALYSIS

Page 9: Suzlon one earth

VALUE PROPOSITION

Page 10: Suzlon one earth

ROAD AHEAD

• USE OF MORE RENEWABLE SOURCE OF ENERGY LIKE WIND AND SOLAR WILL BE GREATLY PREFERRED IN COMING TIMES.

• WASTE MANAGEMENT AND POWER GENERATION SYSTEM USING GREENER TECHNOLOGIES WOULD BE HAVING AN UPPER HAND .

• CARBON EXCHANGE WOULD HAVE A GREATER ROLE TO PLAY AND COULD IMPACT ECONOMIES OF THE NATIONS.

Page 11: Suzlon one earth

Thank You