29° 26' 50" - 50.195m
29° 26' 50" - 49.72m
308° 36' 00" - 25.195m
26° 13' 20" - 23.95m
299° 54' 00" - 30.570m
26° 13' 20" - 18.43m
308° 36' 00"
- 3.15m
1500
4500
1500
easement "C"
2368
5600
31702
118
Property Description
Lot 200 on SP 282407Locality - MareebaMareeba Shire Council
Area of land - 1404 sq mBuilding Classification - Class 1a
All work must be in accordancewith Local Authority By-laws andthe "Building Construction Code odAustralia "
The Builder should verify alldimensions on site beforecommencing any work.
TAKE FIGURED DIMENSIONSIN PREFERENCE TO SCALED
IF IN DOUBT ASK !!
Date
Drawn
Scale
Client
Project
Location
Job No.
Sheet No.
Notes
A.B.N. No. 16 010 608 321
Max Slade Designs Pty. Ltd.
QBSA Lic. No. 659479
Builder - Low Rise
Building Designer - Medium Rise
Beatrice Street
Atherton 4883
Phone 07 40 91 2099
Design Wind Classification - C 2
copyrightC
be aware :- SUBSTITUTION OF ANY STRUCTURAL MEMBERS & OR ANY VARIATIONS TO THE DESIGN WILL VOID ANY RESPONSIBILITY OF THE BUILDING DESIGNER FOR THE STRUCTURAL INTREGITY & PERFORMANCE OF THE BUILDING
23/04/2018 11:52:58 AM
1 : 200
Dual
Occupancy
Units
14 Anzac Avenue
Mareeba
A101
Kevin
O'Brien
M 17 - 4573
Max Slade
July 2017
4 u
nits - C
on
ce
pt #
5 - 0
4 1
8
SUSTAINABLE BUILDING REQUIREMENTS FORCLASS 1 BUILDINGS
Acceptable Solutions:
Shower Roses:Shower Roses to be AAA rating when assessed
against AS/NZ 6400:2004 or
as star rating under the Water Efficiency Labelling
Scheme (WELS).
Water Supply:
In a service area for retail water service under the
Water Act 2000, the water supplied to a
new Class 1 building does not exceed pressure levels
set out in AS/NZ 3550.1:2003 and if
the main water pressure exceeds or could exceed
500 Kpa, a water pressure limiting device
is installed to ensure that the maximum operating
pressure at the outlet within boundaries
of the property does not exceed 500 Kpa.
Volume of Water used in Toilet:
In a new Class 1 building, toilet cisterns have dual
flush capability that does not exceed
4.5 litres on full flush and 3 litres on half flush.
Energy Efficiency Lighting:
In a new Class 1 building, fluorescent lights or
compact fluorescent lights (CFLs) are used
in 80% of the total area of alll rooms. The total
area is to include the fllor area of the garage,
where the garage is associated wit the Class 1
building.
Air conditioning systems must have an Energy
Efficiency Rating of at least 2.9
Hot Water System:
In a new Class 1 building, a hot water supply is
provided by:
(a) Solar hot water system, or
(b) A gas hot water system with a five
star energy rating.
(c) A heat pump system.
GENERAL NOTES
1.1Refer any discrepancy to designer for written
instructions
2. All work to be in accordance with the B.C.A.
Class 1 & 10.
3. Plumbing & Drainage to comply with AS/NZS
3500.
4. Footings to comply with AS 2870.
5. Glasing to comply with AS 1288.
6. Cold formed steel to comply wtih AS/NZS
4600.
7. Timber framing to comply with AS
1684.3-2006.
8. Termite treatment: Timber to be
preservative treated (L.O.S.P.)
in accordance with AS 3660-2000.
9. Stormwater to be discharged to council
regulations.
10. All structural fixed bolts, nuts and washers
to be hot dipped galvanised.
11. Confirm all joinery fit-out details with
proprietor prior to construction.
NORTH
Num
ber
Dat
e D
escr
iptio
n
1 : 200
Site Layout1
NORTH
All work must be in accordancewith Local Authority By-laws andthe "Building Construction Code odAustralia "
The Builder should verify alldimensions on site beforecommencing any work.
TAKE FIGURED DIMENSIONSIN PREFERENCE TO SCALED
IF IN DOUBT ASK !!
Date
Drawn
Scale
Client
Project
Location
Job No.
Sheet No.
Notes
A.B.N. No. 16 010 608 321
Max Slade Designs Pty. Ltd.
QBSA Lic. No. 659479
Builder - Low Rise
Building Designer - Medium Rise
Beatrice Street
Atherton 4883
Phone 07 40 91 2099
Design Wind Classification - C 2
copyrightC
be aware :- SUBSTITUTION OF ANY STRUCTURAL MEMBERS & OR ANY VARIATIONS TO THE DESIGN WILL VOID ANY RESPONSIBILITY OF THE BUILDING DESIGNER FOR THE STRUCTURAL INTREGITY & PERFORMANCE OF THE BUILDING
23/04/2018 11:52:59 AM
1 : 200
Dual
Occupancy
Units
14 Anzac Avenue
Mareeba
A101a
Kevin
O'Brien
M 17 - 4573
Max Slade
July 2017
4 u
nits - C
on
ce
pt #
5 - 0
4 1
8N
umbe
rD
ate
Des
crip
tion
1 : 200
Aerial / Locality Plan1
7600 200 7600
3600 200 3600
3200 51
90
3640
90
2600
600
90
1700
90
1700
4900
2500
10800
2400
UNIT 2 UNIT 1
deck
bedroom 1
bedroom 2
wc
bath l'dry
kitchen
living
dining
garage
visitor
deck
bedroom 1
bedroom 2
wc
bathl'dry
kitchen
living
dining
garage
20600
4900
2500
10800
2400
15800
1700 2300 7800 2300 1700
15800
20600
Dry
ing
/ R
efu
se A
rea
Dry
ing
/ R
efu
se A
rea
All work must be in accordancewith Local Authority By-laws andthe "Building Construction Code odAustralia "
The Builder should verify alldimensions on site beforecommencing any work.
TAKE FIGURED DIMENSIONSIN PREFERENCE TO SCALED
IF IN DOUBT ASK !!
Date
Drawn
Scale
Client
Project
Location
Job No.
Sheet No.
Notes
A.B.N. No. 16 010 608 321
Max Slade Designs Pty. Ltd.
QBSA Lic. No. 659479
Builder - Low Rise
Building Designer - Medium Rise
Beatrice Street
Atherton 4883
Phone 07 40 91 2099
Design Wind Classification - C 2
copyrightC
be aware :- SUBSTITUTION OF ANY STRUCTURAL MEMBERS & OR ANY VARIATIONS TO THE DESIGN WILL VOID ANY RESPONSIBILITY OF THE BUILDING DESIGNER FOR THE STRUCTURAL INTREGITY & PERFORMANCE OF THE BUILDING
23/04/2018 11:53:00 AM
1 : 100
Dual
Occupancy
Units
14 Anzac Avenue
Mareeba
A102a
Kevin
O'Brien
M 17 - 4573
Max Slade
July 2017
4 u
nits - C
on
ce
pt #
5 - 0
4 1
8N
umbe
rD
ate
Des
crip
tion
1 : 100
Duplex 2 - Layout Plan1
135 m²
Unit 2
135 m²
Unit 1968 m²
Area
All work must be in accordancewith Local Authority By-laws andthe "Building Construction Code odAustralia "
The Builder should verify alldimensions on site beforecommencing any work.
TAKE FIGURED DIMENSIONSIN PREFERENCE TO SCALED
IF IN DOUBT ASK !!
Date
Drawn
Scale
Client
Project
Location
Job No.
Sheet No.
Notes
A.B.N. No. 16 010 608 321
Max Slade Designs Pty. Ltd.
QBSA Lic. No. 659479
Builder - Low Rise
Building Designer - Medium Rise
Beatrice Street
Atherton 4883
Phone 07 40 91 2099
Design Wind Classification - C 2
copyrightC
be aware :- SUBSTITUTION OF ANY STRUCTURAL MEMBERS & OR ANY VARIATIONS TO THE DESIGN WILL VOID ANY RESPONSIBILITY OF THE BUILDING DESIGNER FOR THE STRUCTURAL INTREGITY & PERFORMANCE OF THE BUILDING
23/04/2018 11:53:00 AM
1 : 150
Dual
Occupancy
Units
14 Anzac Avenue
Mareeba
A102b
Kevin
O'Brien
M 17 - 4573
Max Slade
July 2017
4 u
nits - C
on
ce
pt #
5 - 0
4 1
8N
umbe
rD
ate
Des
crip
tion
1 : 150
Area Plan1
All work must be in accordancewith Local Authority By-laws andthe "Building Construction Code odAustralia "
The Builder should verify alldimensions on site beforecommencing any work.
TAKE FIGURED DIMENSIONSIN PREFERENCE TO SCALED
IF IN DOUBT ASK !!
Date
Drawn
Scale
Client
Project
Location
Job No.
Sheet No.
Notes
A.B.N. No. 16 010 608 321
Max Slade Designs Pty. Ltd.
QBSA Lic. No. 659479
Builder - Low Rise
Building Designer - Medium Rise
Beatrice Street
Atherton 4883
Phone 07 40 91 2099
Design Wind Classification - C 2
copyrightC
be aware :- SUBSTITUTION OF ANY STRUCTURAL MEMBERS & OR ANY VARIATIONS TO THE DESIGN WILL VOID ANY RESPONSIBILITY OF THE BUILDING DESIGNER FOR THE STRUCTURAL INTREGITY & PERFORMANCE OF THE BUILDING
23/04/2018 11:53:01 AM
Dual
Occupancy
Units
14 Anzac Avenue
Mareeba
A102d
Kevin
O'Brien
M 17 - 4573
Max Slade
July 2017
4 u
nits - C
on
ce
pt #
5 - 0
4 1
8N
umbe
rD
ate
Des
crip
tion
3D View 31
3D View 42
Layout Plan
0
Head
2100
Ceiling Line
2700
Layout Plan
0
Head
2100
Ceiling Line
2700
Layout Plan
0
Head
2100
Ceiling Line
2700
Layout Plan
0
Head
2100
Ceiling Line
2700
All work must be in accordancewith Local Authority By-laws andthe "Building Construction Code odAustralia "
The Builder should verify alldimensions on site beforecommencing any work.
TAKE FIGURED DIMENSIONSIN PREFERENCE TO SCALED
IF IN DOUBT ASK !!
Date
Drawn
Scale
Client
Project
Location
Job No.
Sheet No.
Notes
A.B.N. No. 16 010 608 321
Max Slade Designs Pty. Ltd.
QBSA Lic. No. 659479
Builder - Low Rise
Building Designer - Medium Rise
Beatrice Street
Atherton 4883
Phone 07 40 91 2099
Design Wind Classification - C 2
copyrightC
be aware :- SUBSTITUTION OF ANY STRUCTURAL MEMBERS & OR ANY VARIATIONS TO THE DESIGN WILL VOID ANY RESPONSIBILITY OF THE BUILDING DESIGNER FOR THE STRUCTURAL INTREGITY & PERFORMANCE OF THE BUILDING
23/04/2018 11:53:02 AM
1 : 200
Dual
Occupancy
Units
14 Anzac Avenue
Mareeba
A103
Kevin
O'Brien
M 17 - 4573
Max Slade
July 2017
4 u
nits - C
on
ce
pt #
5 - 0
4 1
8N
umbe
rD
ate
Des
crip
tion
1 : 200
South1
1 : 200
North2
1 : 200
East3
1 : 200
West4