8/18/2019 Surge Test Report Jan 2016
1/17
Surge Test Report
Prepared for
ONGC AssamShivsagar
Visit Nov-Dec 2015Jan 2016
Compressor Controls Corporation’sProject CCC #13796
8/18/2019 Surge Test Report Jan 2016
2/17
Technical Support
For current CCC Customers, please have your CCC project number and call:T: +1-800-387-4652 (US and Canada, Des Moines, Iowa); T: +1-515-251-2736 (Americas and Asia-Pacific, Des Moines, Iowa);T: +31-20-407-0000 (Europe and Africa, Amsterdam);T: +971-2-446 9671 (Middle East, Abu Dhabi);T: +7-495-913-9764 (Russia and CIS, Moscow).
Request Field Service:
• [email protected] - North & South America, Asia and Pacific
• [email protected] - Europe and Africa
• [email protected] - Middle East
• [email protected] - Russia and CIS
Worldwide Offices
CCC Headquarters - Des Moines4725 121st StreetDes Moines, Iowa 50323-2316U.S.A.T: +1-515-270-0857F: +1-515-270-1331
CCC - Australia55 Moss Street,East Fremantle, Perth,Western Australia, 6158T: +61-8-94382321M: +61-488088812
CCC - BrazilRua Victor Civita, 66Bloco 2, sala 214Rio Office Park,
Barra da Tijuca, 22275-044Rio de Janeiro, RJBrazilT: +55-21-3535-9293F: +55-21-3535-9294M: +55-21-9131-2758
CCC - ChinaRm 1001, Sunjoy Mansion,6 Ritan RoadChaoyang Dist.Beijing, 100020Peoples Republic of ChinaT: +86-10-65-07-0590
F: +86-10-65-07-0530
CCC - ItalyCompressor ControlsCorporation Srl,V. le Brianza 20,20092, Cinisello Balsamo,Milan, ItalyT: +39-02-618-0231F: +39-02-618-02330
CCC - NetherlandsWeerenweg 10,1161 AH Zwanenburg,The NetherlandsT: +31-20-407-0000F: +31-20-407-0099
Mailing Address:Compressor Controls
Corporation BV,PO Box 134,1160 AC Zwanenburg,The Netherlands
CCC - RussiaRoper LLCMoscow 115419,Shabolovka street, 34,bldg. 2, office 14T: +7-495-913-9764T: +7-495-617-12-93/94/95F: +7-495-913-9765
CCC - Saudi ArabiaT: +966-3-833-7973F: +966-3-833-0508M: +966-55-512-9014
CCC - Singapore10 Eunos Road 8, #12-06Singapore Post CentreSingapore, 408600T: +65-6408-6220F: +65-6293-3307
CCC - Houston8824 FallbrookHouston, TX 77064-9912U.S.A.T: +1-281-583-7799F: +1-281-583-8788
CCC - India35, 1st Floor, Dheeraj Heritage,S.V. RoadSantacruz (West), Mumbai,Maharashtra, 400054,IndiaT: +91-22-66994803F: +91-22-66994803M: +91-98203-33819
CCC – U.A.E.
Villa 8/1, Ninth (9th) StreetAl Karamah, 109174,Abu Dhabi, U.A.E.T: +971-2-446-9671F: +971-2-446-9772
CCC - UKPinewood, Chineham Business ParkCrockford Lane, ChinehamBasingstokeHampshire RG24 8ALUnited KingdomT: +44-134-470-1807F: +44-125-669-8275
8/18/2019 Surge Test Report Jan 2016
3/17
Compressor Controls Field Service Report
Project 13874
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 3 of 17
8/18/2019 Surge Test Report Jan 2016
4/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 4 of 17
8/18/2019 Surge Test Report Jan 2016
5/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 5 of 17
GGS9-LP Train B Surge test : IGV=15%
8/18/2019 Surge Test Report Jan 2016
6/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 6 of 17
GGS9-LP Train B Surge test : IGV=35%
8/18/2019 Surge Test Report Jan 2016
7/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 7 of 17
GGS9-LP Train B Surge test : IGV=50%
8/18/2019 Surge Test Report Jan 2016
8/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 8 of 17
8/18/2019 Surge Test Report Jan 2016
9/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 9 of 17
8/18/2019 Surge Test Report Jan 2016
10/17
8/18/2019 Surge Test Report Jan 2016
11/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 11 of 17
GGS9-LP Train C Surge test : IGV=35%
8/18/2019 Surge Test Report Jan 2016
12/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 12 of 17
GGS9-LP Train C Surge test : IGV=50%
8/18/2019 Surge Test Report Jan 2016
13/17
8/18/2019 Surge Test Report Jan 2016
14/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 14 of 17
8/18/2019 Surge Test Report Jan 2016
15/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 15 of 17
Train C Surge test, IGV=3.5%
8/18/2019 Surge Test Report Jan 2016
16/17
Compressor Controls Field Service Report
Project 13796
Last printed 10-Feb-16 Dec09 Rev 5.0 Page 16 of 17
Train C surge test, IGV=15%:
8/18/2019 Surge Test Report Jan 2016
17/17
Compressor Controls Field Service Report
Project 13796
Train C surge test, IGV=25%: