40
Enhanced Safety Lowest Cable Cost Per Ton Lowest Cable Cost Per Ton Surface Mining Cables Reduced Downtime Enhanced Safety Reduced Downtime Assembly Solutions Assembly Solutions

Surface Catalog 2 09 - Thorne and Derrick UK a ground check conductor and ... Size AWG 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 ... AWG/Metric Cross Reference Roof Bolter

Embed Size (px)

Citation preview

EnhancedSafety

LowestCable Cost

Per Ton

LowestCable Cost

Per Ton

SurfaceMining Cables

ReducedDowntime

EnhancedSafety

ReducedDowntime

AssemblySolutionsAssemblySolutions

AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listed is approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application.

© 2009, AmerCable Incorporated

36-503 Type SHD-GC 2kV • CPE Jacket . . . . . . . . . . . . . . . . . . . . . . . 2-336-502 Type SHD-GC 2kV • TPU Jacket . . . . . . . . . . . . . . . . . . . . . . . 4-5

36-515 Type SHD-GC 5kV • CPE Jacket . . . . . . . . . . . . . . . . . . . . . . . 6-736-514 Type SHD-GC 5kV • TPU Jacket . . . . . . . . . . . . . . . . . . . . . . . 8-9

36-517 Type SHD-GC 8kV • CPE Jacket . . . . . . . . . . . . . . . . . . . . . 10-1136-518 Type SHD-GC 8kV • TPU Jacket . . . . . . . . . . . . . . . . . . . . . 12-13

36-519 Type SHD-GC 15kV • CPE Jacket . . . . . . . . . . . . . . . . . . . . 14-1536-521 Type SHD-GC 15kV • TPU Jacket . . . . . . . . . . . . . . . . . . . . 16-17

36-525 Type SHD-GC 25kV • CPE Jacket . . . . . . . . . . . . . . . . . . . . 18-1936-526 Type SHD-GC 25kV • TPU Jacket . . . . . . . . . . . . . . . . . . . . 20-21

36-432 Type W (Round) 4/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23

36-442 Type G-GC (Round) 3/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . 24-25

37-119 DLO 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27

36-501 Mining VFD 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-2937-102 Type VFD 2kV (Standard) . . . . . . . . . . . . . . . . . . . . . . . . . 30-31

36-129 Drilling Mast Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33

Jacket Materials & Color Options . . . . . . . . . . . . . . . . . . . . . . 34

Tiger Stripes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Safety, Training and Education . . . . . . . . . . . . . . . . . . . . . . . . 35

Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-37

Index

El Dorado, Arkansas

Made inAmerica

Our Commitment to the Mining Industry

1

Since the electrification of mines, ourcompany’s core business has beenpowering mine equipment.Surface or underground – AmerCable has a cable productivity solution for you. Our innovatively engineered and manufactured Tiger® Brand cable line is designed for your toughest conditions. As a leading global producer of mining cables, AmerCable is dedicated to producing:

■ cables that last longer in harsh mining environments

■ cables designed to help provide greater levels of safety and productivity

■ lowest cable cost per ton!

Mining Cable Innovation■ Designing insulating and jacketing materials that

are more flexible with greater resistance to abrasion and moisture

■ Cable constructions that last longer providing reduced down time for increased production

■ New product development that addresses environmental, safety and cost reduction issuesspecific to your mining application.

Operating Excellence■ On-time delivery backed by our

industry leading shipment percentage of 98%+ averagefor the past 36 months

■ Standard lead-time of 6 to 8 weeks

■ Urgent response shipment capability of 2 to 4 weeks

■ Strategically located inventories throughout the major mining regions.

■ AmerCable is an ISO-9001 certified manufacturer

Hands-on Field SupportOur mine-experienced field application engineers are available24/7 for on-site evaluation andsolutions. They also conduct education and training sessionsthat address safety, splicing and cable handling issues. See page 35 for more information.

Surface Mining CablesSurface Mining Cables

Factory Installed Cable AssembliesSee pages

36-37for more

information.SAVE

TIME &MONEY

36-503

Type SHD-GCMold-cured CPE Jacket • 2000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96132

ApplicationHeavy duty portable power cable for use in circuits not exceeding 2,000 volts. Designedfor applications such as longwall shearers,continuous miners, loaders, drills, conveyors,pumps and mobile equipment where groundingconductors, a ground check conductor andmetallic shielding are required. Recommendedmaximum continuous conductor temperatureis 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.

Jacket3

Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.

ConductorsFlexible tinned copper

TapeNon-conducting

Insulation90°C ethylene-propylenerubber (EPR)

Ground WiresFlexible tinned copper

Ground Check Conductor2

Flexible tinned copperwith yellow polypropyleneinsulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Natural Resources Canada Certification No. 910. Type SHD-GC, SHD-BGC up to 25kV Type W, G, G-GC, BGC up to 2kV

� Canadian Standards Association File 82346, FT1, FT5 CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV

Ratings & Approvals

InsulationShieldingTinned copperand color codednylon braid

Separator Tape

See Page 34 for jacket color options.

Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacket for extremely abrasive environments! See next page.

See Page 34 for Tiger Stripe options

PureIntegral Fill

for greatertorsion

resistance

PureIntegral Fill

Photo courtesy Bucyrus

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 3

Surface Mining CablesSurface Mining Cables

36-503 • Type SHD-GC 3/C • CPE Jacket • 2000 Volts

Primary UsageRecommendation

ContinuousMiner

Longwall Miner

Pump

1 Ampacity – Based on continuous duty at 90°C conductor temperature.

2Ground Check Conductor – 10 AWG (minimum 49strand 7x7) ground check conductor on 8 AWG through 2 AWG cable.

8 AWG (minimum 133 strand 7x19) ground check conductor on 1 AWG through 4/0 AWG cable.

6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

3 Jacket – CPE jacket. Black CPE is standard. Colored CPE available upon request. See page 34 for color options.

Tolerances – ± 5% of nominal outside diameter

SizeAWG

6421

1/02/03/04/0250350500

SizeAWG108654321

1/02/04/0

No. of Wiresper

Conductor133259259259266323418532627888

1221

No. of Wiresper

Conductor49

133133133259259259259266323532

InsulationThickness

mils7070708080808080959595

NominalOutside

Dimensions in.

1.291.401.591.761.862.002.132.312.512.813.19

Jacket Thickness

mils155155170190190205205220220235265

Approx.Weightlbs. per1,000 ft.

1160149020002450284034003680486059507400

10100

Ampacity 1

40°CAmbient Temp

93122159184211243279321355435536

Power Conductors Grounding Conductors

36-503-006004002001010020030040250350500

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

RoofBolter

Photo courtesy P&H

Blast Hole Driller

36-502

Type SHD-GCTPU Jacket • 2000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96134

ApplicationHeavy duty portable power cable for use in circuits not exceeding 2,000 volts. Designedfor applications such as longwall shearers,continuous miners, loaders, drills, conveyors,pumps and mobile equipment where groundingconductors, a ground check conductor andmetallic shielding are required. Recommendedmaximum continuous conductor temperatureis 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.

Jacket3

Thermoplastic Polyurethane(TPU) Jacket. Cable identification via permanent marking.

ConductorsFlexible tinned copper

TapeNon-conducting

Insulation90°C ethylene-propylenerubber (EPR)

Ground WiresFlexible tinned copper

Ground Check Conductor2

Flexible tinned copperwith yellow polypropyleneinsulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Canadian Standards Association (pending)File 82346, FT1, FT5 CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kV

Ratings & Approvals

Fillers

InsulationShieldingTinned copperand color codednylon braid

Separator Tape

See Page 34 for TPU jacket color options.

Also available with mold-cured thermosettingChlorinated Polyethylene(CPE) jacket. See previous page.

Rubber Filler and Tape Core

RubberFiller andTape Core

Assembly Taped core

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 5

Surface Mining CablesSurface Mining Cables

Photo courtesy P&H

36-502 • Type SHD-GC 3/C • TPU Jacket • 2000 Volts

Primary UsageRecommendation

ContinuousMiner

Longwall Miner

Pump

1 Ampacity – Based on continuous duty at 90°C conductor temperature.

2Ground Check Conductor – 10 AWG (minimum 49strand 7x7) ground check conductor on 8 AWG through 2 AWG cable.

8 AWG (minimum 133 strand 7x19) ground check conductor on 1 AWG through 4/0 AWG cable.

6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

3 Jacket – Standard jacket is black. See page 34 for color options

Tolerances – ± 5% of nominal outside diameter

SizeAWG

6421

1/02/03/04/0250350500

SizeAWG108654321

1/02/04/0

No. of Wiresper

Conductor133259259259266323418532627888

1221

No. of Wiresper

Conductor49

133133133259259259259266323532

InsulationThickness

mils7070708080808080959595

NominalOutside

Dimensions in.

1.2901.4001.5901.7601.8602.0002.1302.3102.5102.8103.190

Jacket Thickness

mils155155170190190205205220220235265

Approx.Weightlbs. per1,000 ft.

10691295177821632508300134704192521368249014

Ampacity 1

40°CAmbient Temp

93122159184211243279321355435536

Power Conductors Grounding Conductors

36-502-006004002001010020030040250350500

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

RoofBolter

Blast Hole Driller

36-515

Type SHD-GC 3/CMold-cured CPE Jacket • 5000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96136

ApplicationHeavy duty portable power cable for use in circuits not exceeding 5,000 volts. Designedfor applications such as longwall shearers,continuous miners, shovels, dredges and drills.Recommended maximum continuous conductor temperature in 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.

Jacket1

Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.

ConductorsFlexible tinned copper

TapeNon-conducting

Insulation90°C ethylene-propylenerubber (EPR)

Ground WiresFlexible tinned copper

Strand ShieldSemi-conducting layer

Ground Check Conductor2

Flexible tinned copper with yellow polypropylene insulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Natural Resources Canada Certification No. 910. Type SHD-GC, SHD-BGC up to 25kV Type W, G, G-GC, BGC up to 2kV

� Canadian Standards Association File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV

InsulationShieldingTinned copperand color codednylon braid

Assembly Taped core

Separator Tape

Photo courtesy P&H

Ratings & Approvals

See Page 34 for jacket color options.

Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacket for extremely abrasive environments! See next page.

See Page 34 for Tiger Stripe options

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 7

Surface Mining CablesSurface Mining Cables

36-515 • Type SHD-GC 3/C • CPE Jacket • 5000 Volts

Primary UsageRecommendation

Longwall Miner

1 Jacket – CPE jacket. Black CPE is standard. Colored CPE available upon request. See page 34 for color options.

2Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 6 AWGthrough 4/0 AWG cable.

6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

3 Ampacity – Based on continuous duty at 90°C conductor temperature.

Tolerances – +8%/-5% of nominal outside diameter

SizeAWG

6421

1/02/03/04/0250350500

SizeAWG108654321

1/02/04/0

No. of Wiresper

Conductor133259259259266323418532627888

1221

No. of Wiresper

Conductor49

133133133259259259259266323532

InsulationThickness

mils110110110110110110110110120120120

NominalOutside

Dimensions in.

1.561.681.871.952.082.202.362.502.692.953.31

Jacket Thickness

mils185185205205220220235235250265280

Approx.Weightlbs. per1,000 ft.

1560192025002860339038304418530064507880

10440

Ampacity 3

40°CAmbient Temp

93122159184211243279321355435536

Power Conductors Grounding Conductors

36-515-006004002001010020030040250350500

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

Photo courtesy Bucyrus

ContinuousMiner

Loading Shovel

Blast Hole Driller

36-514

Type SHD-GC 3/CTPU Jacket • 5000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96138

ApplicationHeavy duty portable power cable for use in circuits not exceeding 5,000 volts. Designedfor applications such as longwall shearers,continuous miners, shovels, dredges and drills.Recommended maximum continuous conductor temperature in 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.

Jacket1

Thermoplastic Polyurethane(TPU) Jacket. Cable identification via permanent marking.

ConductorsFlexible tinned copper

TapeNon-conducting

Insulation90°C ethylene-propylenerubber (EPR)

Ground WiresFlexible tinned copper

Strand ShieldSemi-conducting layer

Ground Check Conductor2

Flexible tinned copper with yellow polypropylene insulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Canadian Standards Association (pending) File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kV

InsulationShieldingTinned copperand color codednylon braid

Assembly Taped core

Separator Tape

Black jacket standard.See Page 34 for TPU jacket color options.

Also available with mold-cured thermosettingChlorinated Polyethylene(CPE) jacket. See Previous page.

Photo courtesy P&H

Ratings & Approvals

Fillers

Rubber Filler and Tape Core

RubberFiller andTape Core

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 9

Surface Mining CablesSurface Mining Cables

36-514 • Type SHD-GC 3/C • TPU Jacket • 5000 Volts

Primary UsageRecommendation

Longwall Miner

1 Jacket – Standard jacket is black.See page 34 for TPU jacket color options.

2Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 6 AWGthrough 4/0 AWG cable.

6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

3 Ampacity – Based on continuous duty at 90°C conductor temperature.

Tolerances – +8%/-5% of nominal outside diameter

SizeAWG

6421

1/02/03/04/0250350500

SizeAWG108654321

1/02/04/0

No. of Wiresper

Conductor133259259259266323418532627888

1221

No. of Wiresper

Conductor49

133133133259259259259266323532

InsulationThickness

mils110110110110110110110110120120120

NominalOutside

Dimensions in.

1.5601.6801.8701.9502.0802.2002.3602.5002.6902.9503.310

Jacket Thickness

mils185185205205220220235235250265280

Approx.Weightlbs. per1,000 ft.

13421629222824472760323837924548542770709407

Ampacity 3

40°CAmbient Temp

93122159184211243279321355435536

Power Conductors Grounding Conductors

36-514-006004002001010020030040250350500

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

Photo courtesy Bucyrus

ContinuousMiner

Loading Shovel

Blast Hole Driller

36-517

Type SHD-GC 3/CMold-cured CPE Jacket • 8000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961310

ApplicationHeavy duty high voltage portable power cablefor use in circuits not exceeding the rated voltage. These cables are used for heavymobile equipment such as drag lines, shovels,dredges, drills and for power feeders.Recommended maximum continuous conductor temperature in 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.Jacket3

Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.

ConductorsFlexible tinned copper

Insulation90°C ethylene-propylenerubber (EPR)

Ground WiresFlexible tinned copper

Strand ShieldSemi-conducting layer

Ground Check Conductor2

Flexible tinned copper with yellow polypropylene insulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables

� Natural Resources Canada Certification No. 910. Type SHD-GC, SHD-BGC up to 25kV Type W, G, G-GC, G-BGC up to 2kV

� Canadian Standards Association File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV

InsulationShieldingTinned copperand color codednylon braid

Assembly Taped coreInsulation Shielding

Semi-conducting tape

Photo courtesy Bucyrus

Ratings & Approvals

See Page 34 for jacket color options.

Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacket for extremely abrasive environments! See next page.

See Page 34 for Tiger Stripe options

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 11

Surface Mining CablesSurface Mining Cables

36-517 • Type SHD-GC • CPE Jacket • 8000 Volts

Primary UsageRecommendation

Loading Shovel

Dragline

Blast Hole Driller

1 Ampacity – Based on continuous duty at 90°C conductor temperature.

2Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 4 AWGthrough 4/0 AWG cable.6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

3 Jacket – CPE jacket. Black CPE is standard. Colored CPE available upon request. See page 34 for color options.

Tolerances – +8%/-5% of nominal outside diameter

SizeAWG

421

1/02/03/04/0250350500

SizeAWG

8654321

1/02/04/0

No. of Wiresper

Conductor259259259266323418532627888

1221

No. of Wiresper

Conductor2

133133133259259259259266323532

InsulationThickness

mils150150150150150150150150150150

NominalOutside

Dimensions in.

1.942.122.212.322.462.622.752.893.203.56

Jacket Thickness

mils205220220220235250250250280295

Approx.Weightlbs. per1,000 ft.

218028303350359041905075566067408460

10700

Ampacity 1

40°CAmbient Temp

122159184211243279321355435536

Power Conductors Grounding Conductors

36-517-004002001010020030040250350500

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

Photo courtesy P&H

36-518

Type SHD-GC 3/CTPU Jacket • 8000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961312

ApplicationHeavy duty high voltage portable power cablefor use in circuits not exceeding the rated voltage. These cables are used for heavymobile equipment such as drag lines, shovels,dredges, drills and for power feeders.Recommended maximum continuous conductor temperature in 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.Jacket3

Thermoplastic Polyurethane(TPU) Jacket. Cable identification via permanent marking.

ConductorsFlexible tinned copper

Insulation90°C ethylene-propylenerubber (EPR)

Ground WiresFlexible tinned copper

Strand ShieldSemi-conducting layer

Ground Check Conductor2

Flexible tinned copper with yellow polypropylene insulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables

� Canadian Standards Association (pending)File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kV

InsulationShieldingTinned copperand color codednylon braid

Assembly Taped core

Insulation ShieldingSemi-conducting tape

Photo courtesy Bucyrus

Ratings & Approvals

Black jacket standard.See Page 34 for TPU jacket color options.

Also available with mold-cured thermosettingChlorinated Polyethylene(CPE) jacket. See Previous page.

Fillers

Rubber Filler and Tape Core

RubberFiller andTape Core

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 13

Surface Mining CablesSurface Mining Cables

36-518 • Type SHD-GC • TPU Jacket • 8000 Volts

Primary UsageRecommendation

Loading Shovel

Dragline

Blast Hole Driller

1 Ampacity – Based on continuous duty at 90°C conductor temperature.

2Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 4 AWGthrough 4/0 AWG cable.6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

3 Jacket – Standard jacket is black.See page 34 for TPU jacket color options.

Tolerances – +8%/-5% of nominal outside diameter

SizeAWG

421

1/02/03/04/0250350500

SizeAWG

8654321

1/02/04/0

No. of Wiresper

Conductor259259259266323418532627888

1221

No. of Wiresper

Conductor2

133133133259259259259266323532

InsulationThickness

mils150150150150150150150150150150

NominalOutside

Dimensions in.

1.9402.1202.2102.3202.4602.6202.7502.8903.2003.560

Jacket Thickness

mils205220220220235250250250280295

Approx.Weightlbs. per1,000 ft.

201926032913335139464582532161017696

10199

Ampacity 1

40°CAmbient Temp

122159184211243279321355435536

Power Conductors Grounding Conductors

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

Photo courtesy P&H

36-518-004002001010020030040250350500

36-519

Type SHD-GC 3/CMold-cured CPE Jacket • 15000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961314

ApplicationHeavy duty high voltage portable power cablefor use in circuits not exceeding the rated voltage. These cables are used for heavymobile equipment such as drag lines, shovels,dredges, drills and for power feeders.Recommended maximum continuous conductor temperature in 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.

Jacket2

Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.

ConductorsFlexible tinned copper

Insulation90°C ethylene-propylenerubber (EPR)

Ground WiresFlexible tinned copper

Strand ShieldSemi-conducting layer

Ground Check Conductor3

Flexible tinned copper with yellow polypropylene insulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Natural Resources Canada Certification No. 910. Type SHD-GC, SHD-BGC up to 25kV Type W, G, G-GC, G-BGC up to 2kV

� Canadian Standards Association File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV

InsulationShieldingTinned copperand color codednylon braid

Assembly Taped core

Insulation ShieldingSemi-conducting tape

Photo courtesy Bucyrus

Ratings & Approvals

See Page 34 for jacket color options.

Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacket for extremely abrasive environments! See next page.

See Page 34 for Tiger Stripe options

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 15

Surface Mining CablesSurface Mining Cables

36-519 • Type SHD-GC 3/C • CPE Jacket • 15000 Volts

Primary UsageRecommendation

Loading Shovel

Dragline

1 Ampacity – Based on continuous duty at 90°C conductor temperature.

2 Jacket – CPE jacket. Black CPE is standard. Colored CPE available upon request. See page 34 for color options.

3Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 4 AWG through 4/0 AWG cable.6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

Tolerances – +8%/-5% of nominal outside diameter

SizeAWG

21

1/02/03/04/0250350500

SizeAWG

654321

1/02/04/0

No. of Wiresper

Conductor259259266323418532627888

1221

No. of Wiresper

Conductor133133259259259259266323532

InsulationThickness

mils210210210210210210210210210

NominalOutside

Dimensions in.

2.412.522.642.732.903.053.103.403.65

Jacket Thickness

mils235235250255265265265280280

Approx.Weightlbs. per1,000 ft.

35004080461048905589682069609128

11020

Ampacity 1

40°CAmbient Temp

164187215246283325359437534

Power Conductors Grounding Conductors

36-519-002001010020030040250350500

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

Photo courtesy P&H

36-521

Type SHD-GC 3/CTPU Jacket • 15000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961316

ApplicationHeavy duty high voltage portable power cablefor use in circuits not exceeding the rated voltage. These cables are used for heavymobile equipment such as drag lines, shovels,dredges, drills and for power feeders.Recommended maximum continuous conductor temperature in 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.

Jacket2

Thermoplastic Polyurethane(TPU) Jacket. Cable identification via permanent marking.

ConductorsFlexible tinned copper

Insulation90°C ethylene-propylenerubber (EPR)

Ground WiresFlexible tinned copper

Strand ShieldSemi-conducting layer

Ground Check Conductor3

Flexible tinned copper with yellow polypropylene insulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Canadian Standards Association (pending)File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kV

InsulationShieldingTinned copperand color codednylon braid

Assembly Taped core

Insulation ShieldingSemi-conducting tape

Photo courtesy Bucyrus

Ratings & Approvals

Black jacket standard.See Page 34 for jacketcolor options.

Also available with mold-cured thermosettingChlorinated Polyethylene(CPE) jacket. See Previous page.

Fillers

Rubber Filler and Tape Core

RubberFiller andTape Core

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 17

Surface Mining CablesSurface Mining Cables

36-521 • Type SHD-GC 3/C • TPU Jacket • 15000 Volts

Primary UsageRecommendation

Loading Shovel

Dragline

1 Ampacity – Based on continuous duty at 90°C conductor temperature.

2 Jacket – Standard jacket is black.See page 30 for TPU jacket color options.

3Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 4 AWG through 4/0 AWG cable.6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

Tolerances – +8%/-5% of nominal outside diameter

SizeAWG

21

1/02/03/04/0250350500

SizeAWG

654321

1/02/04/0

No. of Wiresper

Conductor259259266323418532627888

1221

No. of Wiresper

Conductor133133259259259259266323532

InsulationThickness

mils210210210210210210210210210

NominalOutside

Dimensions in.

2.4102.5202.6402.7302.9003.050N/AN/AN/A

Jacket Thickness

mils235235250255265265265280280

Approx.Weightlbs. per1,000 ft.

31453567397645265231603366028306

10497

Ampacity 1

40°CAmbient Temp

164187215246283325359437534

Power Conductors Grounding Conductors

36-521-002001010020030040250350500

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

Photo courtesy P&H

36-525

Type SHD-GC 3/CMold-cured CPE Jacket • 25000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961318

ApplicationHeavy duty high voltage portable power cablefor use in circuits not exceeding the rated voltage. These cables are used for heavymobile equipment such as drag lines, shovels,dredges, drills and for power feeders.Recommended maximum continuous conductor temperature in 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.

Jacket2

Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.

ConductorsFlexible tinned copper

Insulation ShieldingSemi-conducting rubberand semi-conductive tape

Ground WiresFlexible tinned copper

Strand ShieldSemi-conducting layer

Ground Check Conductor3

Flexible tinned copper with yellow polypropylene insulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Natural Resources Canada Certification No. 910. Type SHD-GC, SHD-BGC up to 25kV Type W, G, G-GC, BGC up to 2kV

� Canadian Standards Association File 82346, FT1, FT5, -50°CCSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV

InsulationShieldingTinned copperand color codednylon braid

Assembly Taped core

Insulation 90°C ethylene-propylenerubber (EPR)

Photo courtesy P&H

Ratings & Approvals

See Page 34 for jacket color options.

Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacket for extremely abrasive environments! See next page.

See Page 34 for Tiger Stripe options

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 19

Surface Mining CablesSurface Mining Cables

36-525 • Type SHD-GC 3/C • CPE Jacket • 25000 Volts

Primary UsageRecommendation

Dragline

1 Ampacity – Based on continuous duty at 90°C conductor temperature.

2 Jacket – CPE jacket. Black CPE is standard. Colored CPE available upon request. See page 34 for color options.

3Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 4 AWG through 4/0 AWG cable.6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

Tolerances – +8%/-5% of nominal outside diameter

SizeAWG

11/02/03/04/0250350

SizeAWG

54321

1/02/0

No. of Wiresper

Conductor259266323418532627888

No. of Wiresper

Conductor133259259259259266323

InsulationThickness

mils260260260260260260260

NominalOutside

Dimensions in.

2.953.053.203.333.503.543.85

Jacket Thickness

mils265265280280295295295

Approx.Weightlbs. per1,000 ft.

532058406550667083508085

10040

Ampacity 1

40°CAmbient Temp

191218249286327360439

Power Conductors Grounding Conductors

36-525-001010020030040250350

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

36-526

Type SHD-GC 3/CTPU Jacket • 25000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961320

ApplicationHeavy duty high voltage portable power cablefor use in circuits not exceeding the rated voltage. These cables are used for heavymobile equipment such as drag lines, shovels,dredges, drills and for power feeders.Recommended maximum continuous conductor temperature in 90°C.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.

Jacket2

Thermoplastic Polyurethane(TPU) Jacket. Cable identification via permanent marking.

ConductorsFlexible tinned copper

Insulation ShieldingSemi-conducting rubberand semi-conductive tape

Ground WiresFlexible tinned copper

Strand ShieldSemi-conducting layer

Ground Check Conductor3

Flexible tinned copper with yellow polypropylene insulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Canadian Standards Association (pending)File 82346, FT1, FT5, -50°CCSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kV

InsulationShieldingTinned copperand color codednylon braid

Assembly Taped core

Insulation 90°C ethylene-propylenerubber (EPR)

Photo courtesy P&H

Ratings & Approvals

Black jacket standard.See Page 34 for jacketcolor options.

Also available with mold-cured thermosettingChlorinated Polyethylene(CPE) jacket. See Previous page.

Fillers

Rubber Filler and Tape Core

RubberFiller andTape Core

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 21

Surface Mining CablesSurface Mining Cables

36-526 • Type SHD-GC 3/C • TPU Jacket • 25000 Volts

Primary UsageRecommendation

Dragline

1 Ampacity – Based on continuous duty at 90°C conductor temperature.

2 Jacket – Standard jacket is black.See page 34 for TPU jacket color options.

3Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 4 AWG through 4/0 AWG cable.6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.

Tolerances – +8%/-5% of nominal outside diameter

SizeAWG

11/02/03/04/0250350

SizeAWG

54321

1/02/0

No. of Wiresper

Conductor259266323418532627888

vvNo. of Wires

perConductor

133259259259259266323

InsulationThickness

mils260260260260260260260

NominalOutside

Dimensions in.

2.9503.0503.2003.3303.500N/AN/A

Jacket Thickness

mils265265280280295295295

Approx.Weightlbs. per1,000 ft.

4410486655606192711076929608

Ampacity 1

40°CAmbient Temp

191218249286327360439

Power Conductors Grounding Conductors

36-526-001010020030040250350

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

36-432

Type W Round 4/CMold-cured Jacket • 2000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961322

ApplicationEspecially suitable for use with mobile miningequipment such as continuous miners, drills,cutters, loading machines, AC shuttle cars andpumps. Type W is for applications where baregrounding conductors are not required ordesired. Recommended maximum continuous conductor temperature is 90°C.

Cable carries “P-7K-184 MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.

Insulation90°C ethylene-propylenerubber (EPR)

Jacket1

Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.

ConductorsFlexible tinned copper

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Natural Resources Canada Certification No. 910. Type SHD-GC, SHD-BGC up to 25kV Type W, G, G-GC, G-BGC up to 2kV

� Canadian Standards Association File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV

See Page 34 for jacketcolor options.

See Page 34 for Tiger Stripe options

TapeNon-conducting

Photo courtesy Bucyrus

Ratings & Approvals

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 23

Surface Mining CablesSurface Mining Cables

36-432 • Type W Round 4/C • 2000 Volts

Primary UsageRecommendation

1 Jacket – Black CPE is standard. Colored CPE jackets available upon request.

2 Ampacity – Based on continuous duty at 90°C conductor temperature.

Tolerances – ± .030" 8-1 AWG± .040" 1/0 - 2/0 AWG± .050" 3/0 - 4/0 AWG

SizeAWG

86421

1/02/03/04/0

36-432-008006004002001010020030040

No. of Wiresper

Conductor133133259259259266323418532

InsulationThickness

mils606060608080808080

NominalOutside

Dimensions in..99

1.101.271.481.681.791.932.072.26

Approx.Weightlbs. per1,000 ft.

670890

1250180022702680320036274650

Ampacity 2

40°CAmbient Temp

547293

122143165192221255

Power Conductors

Number of MultiplyingLayers Correction Factors

1 0.852 0.653 0.454 0.35

Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.

Pump

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

ContinuousMiner

Blast Hole Driller

36-442

Type G-GC Round 3/CMold-cured Jacket • 2000 Volts

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961324

ApplicationEspecially suitable for use with mobile miningequipment such as continuous miners, drills,cutters, loading machines, AC shuttle cars andpumps. Type G-GC is for applications wheregrounding conductors and a ground check conductor are required. Recommended maximum continuous conductor temperature is 90°C.

Cable carries “P-7K-184 MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.

Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.

Insulation90°C ethylene-propylenerubber (EPR)

Jacket1

Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.

ConductorsFlexible tinned copper

Ground WiresFlexible tinned copper

Ground Check Conductor2

Flexible tinned copper with yellow polypropyleneinsulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.

� Natural Resources Canada Certification No. 910. Type SHD-GC, SHD-BGC up to 25kV Type W, G, G-GC, G-BGC up to 2kV

� Canadian Standards Association File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTOType SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV

See Page 34 for jacketcolor options.

See Page 34 for Tiger Stripe options

Separator TapeNon-conductive

Photo courtesy Bucyrus

Ratings & Approvals

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 25

Surface Mining CablesSurface Mining Cables

Primary UsageRecommendation

Pump

1 Jacket – Black CPE is standard. Colored CPE jackets available upon request.

2Ground Check Conductor – 10 AWG (minimum 49strand 7x7) ground check conductor on 8 AWGthrough 2 AWG cable.

8 AWG (minimum 133 strand 7x19) ground checkconductor on 1 AWG through 4/0 AWG cable.

6 AWG (minimum 133 strand 7x19) ground checkconductor on 250 kcmil and larger cable.

3 Ampacity – Based on continuous duty at 90°C conductor temperature.

Tolerances – ± .030" 8-1 AWG± .040" 1/0 - 2/0 AWG± .050" 3/0 - 4/0 AWG± .060" 250 - 500 kcmil

36-442 • Type G-GC Round 3/C • 2000 Volts

SizeAWG

86421

1/02/03/04/0250350500

SizeAWG101087654222

1/02/0

No. of Wiresper

Conductor133259259259259266323418532627888

1221

No. of Wiresper

Conductor4949

133133133133259259259259266323

InsulationThickness

mils606060608080808080959595

NominalOutside

Dimensions in..97

1.051.191.341.511.651.751.892.042.392.683.03

Approx.Weightlbs. per1,000 ft.

600750

1070148018902340275033773980500067508900

Ampacity 3

40°CAmbient Temp

5979

104138161186215249287320394487

Power Conductors Grounding Conductors

36-442-008006004002001010020030040250350500

Number of MultiplyingLayers Correction Factors

1 0.852 0.653 0.454 0.35

Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

ContinuousMiner

Blast Hole Driller

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961326

37-119

Flexible Power Cable • DLOEP/CPE • RHH, RHW-2 • 2000 Volts

ApplicationTiger® Brand 2000V Diesel Locomotive Cable(DLO) is a single conductor Portable PowerCable suitable for use in industrial applicationsneeding great flexibility, excellent wearability anda good flex life.

FFeeaattuurreess� A two layer composite of flame retardant, oil

and sunlight resistant Chlorinated Polyethylene(CPE) outer layer and Ethylene-Propylene rubber (EPR) inner layer. The compositedesign provides significant diameter reductions compared to designs using full thickness jackets.

� Suitable for continuous operating temperatures of 90°C, wet or dry

� Flame Resistance: FT-4/IEEE1202 for 2/0 – 1000 kcmil and UL VW-1

� Meets smoke release and other requirementsof Vertical Cable Tray Test UL 1685 and ismarked “LS” for 2/0 – 1000 kcmil

� Extremely flexible stranding used for increasedflexibility and ease of installation

Insulation90°C ethylene-propylenerubber (EPR)

JacketFlame retardant, oil and sunlight retardantChlorinated Polyethylene (CPE)

See Page 34 for jacket color options.

ConductorsFlexible tinned copper

SeparatorSuitable separator tapeprovides easy strippingof insulation

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� UL Standard 44: Thermoset Insulated Wires &Cables, Types RHH, RHW-2. UL VW-1.

� UL Standard 1685: Vertical Tray Fire propagation and Smoke Release Test forElectrical and optical Fiber Cables. (UL, LS)

� AAR 591 Wire and Cable Insulating Material:Strand Construction except 3/0 and 4/0.

� ASTM B-33: Standard Specification for TinnedSoft or Annealed Copper Wire for ElectricalPurposes.

� ASTM B-172: Standard Specification for Rope-Lay-Stranded Copper Conductors havingBunch-Stranded Members, for ElectricalConductors.

� MSHA P-184

Ratings & Approvals

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 27

Surface Mining CablesSurface Mining Cables

* Ampacity – Calculated with at 90°C conductor temperature and 30°C ambient air, per2002 NEC, Table 310-17

• Cable diameters are subject to +/-5% manufacturingtolerance

• Sizes above 1000 kcmil are not UL listed

37-119 • Portable Power Cable • 2000 Volts

201 14 19 0.045 0.015 0.214 31 35202 12 19 0.045 0.015 0.233 41 40203 10 27 0.045 0.015 0.257 58 55204 8 37 0.055 0.030 0.326 86 80205 6 61 0.055 0.030 0.365 124 105207 4 105 0.055 0.030 0.460 198 140209 2 147 0.055 0.030 0.498 261 190210 1 224 0.065 0.045 0.618 400 220211 1/0 266 0.065 0.045 0.664 468 260212 2/0 323 0.065 0.045 0.704 561 300213 3/0 418 0.065 0.045 0.789 725 350214 4/0 532 0.065 0.045 0.839 888 405215 262 646 0.075 0.065 0.973 1048 467216 313 777 0.075 0.065 1.029 1227 522217 373 925 0.075 0.065 1.094 1436 591218 444 1110 0.075 0.065 1.169 1691 652219 535 1332 0.090 0.065 1.295 2034 728220 646 1591 0.090 0.065 1.368 2395 815221 777 1924 0.090 0.065 1.488 2837 904222 929 2318 0.090 0.065 1.583 3448 1005223 1111 2745 0.130 0.065 1.707 4156 1119

Approx.Weightlbs. per1,000 ft.

*Ampacity90°C

Part No.37-119-

SizeAWG/kcmil

MinimumWires perConductor

NominalInsulationThickness

in.

NominalJacket

Thickness in.

NominalOutside

Diameter in.

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961328

36-501

VFD Power Cable • Shielded • 2000 Volts3 Conductors + 3 Grounds + Ground Check(s)

ApplicationA flexible, braid and foil shielded, 2kV powercable specifically engineered for use in variablefrequency AC motor drive (VFD) applications.

Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.

Tiger® Brand Mining Cable materials meet orexceed ICEA Standard S-75-381/NEMA WC-58for Type SHC constructions. ASTM B-172 andB-33.

JacketReinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.

See Page 34 for jacket color options.

Ground Conductors (x3)Flexible tinned rope stranded conductors perASTMB-172 and B-33,Insulated and colored green

Ground CheckWire(s)Flexible tinnedcopper with yellow insulation.Center groundcheck available

ShieldOverall tinned copper braid plus aluminum/polyester tape providing100% coverage

InsulationType II EPDM (EPR) suitablefor continuous operation at90°C. Ozone resistant.

Round-shaped cross-section

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� 90˚C Temperature Rating

� Tiger® Brand Mining Cable materials meet or exceed ICEA Standard S-75-381/NEMA WC-58.

� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� Canadian Standards Association (pending)File 82346CSA Phase Color ID available on MTO

Power ConductorExtra flexibletinned ropestranded conductors perASTM-172 and B-33

Photo courtesy OEM

Ratings & Approvals

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 29

Surface Mining CablesSurface Mining Cables

36-501 • VFD Power Cable • 2000 Volts

*Cable diameters are subject to a +/- 5% manufacturing tolerance

1Ground Check Conductor – #16 AWG extensible strand for center groundcheck.#14 AWG is the minimum size for non-center ground check wires

2Ampacity Ratings – based on continuous duty at90°C conductor temperature

002 2 8 0.155 1.43 1790 159001 1 7 0.170 1.64 2150 184010 1/0 6 0.170 1.74 2550 211020 2/0 5 0.190 1.89 3100 243030 3/0 4 0.190 2.01 4050 279040 4/0 3 0.220 2.17 4390 321250 250 3 0.220 2.40 5950 355350 350 1 0.220 2.68 7840 405500 500 1/0 0.265 3.03 9730 536

Part No.36-501

PowerConductor

SizeAWG/kcmil

NNoommiinnaallJacket

Thicknessin.

GroundingConductorsSize AWG1

NominalDiameter

in.

Approx.Weightlbs./ft.

Ampacity2

90°C

Correction FactorsFor ampacities for various ambient temperatures above or below 40°C.

Ambient Temp. MultiplyingDegrees C Correction Factors

10 1.2620 1.1830 1.1040 1.0050 0.90

Nearest StandardMetric Cond.

mm2

0.500.501.001.502.50

46

1016253550507095

120120150185240240300400400500

Area ofAWG/kcmil

in mm2

0.350.520.821.312.083.315.268.37

13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7

AWG/kcmilSize

2220181614121086421

1/02/03/04/0250300350400500600750800

1000

AWG/Metric Cross Reference

37-102VFD

Standard Type VFD Power Cable2kV • Rated 110°C • Gexol® Insulated

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961330

ApplicationA flexible, braid and foil shielded, 2kV powercable specifically engineered for use in variablefrequency AC motor drive (VFD) applications.

Features� Specially engineered cable design produces

a longer cable life in VFD applications.� Overall braid plus foil shield is engineered

with 100% coverage and a surface transferimpedance <50 milliohms at 10MHz to contain EMI.

� Symmetrical insulated ground conductorsreduce induced voltage imbalances and carrycommon mode noise back to the drive.

� High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable.

� Gexol’s lower dielectric constant (standardXLPEs, EPRs and other Type P insulation materials have higher dielectric constants)reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system.

� 2kV insulation thickness is used to resist thepotential 2-3x reflected voltages experienced in 600V VFD applications.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 andZone 1 environments (armored andsheathed).

� Optional braid armor of bronze, aluminum or tinned copper.

Insulation (2kV)Gexol® cross-linked flameretardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.

Color: Gray with printed phase I.D.(Black-White-Red)

JacketA black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.

Power Conductors (x3)Soft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

Ground Conductors (x3)Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.Gexol®-HF insulated and sized per UL 1277.Color: Green

Armor (Optional)Basket weave wirearmor per IEEE 1580and UL 1309/CSA 245.Bronze standard.Aluminum or tinned copper availableby request.

ShieldOverall tinned copperbraid plus aluminum/polyester tape providing100% coverage.

Sheath (Optional)A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.

Ratings & Approvals� Mine Safety & Health Administration 184-MSHA.

� Pennsylvania Department of Environmental Protection P-184.

� 110˚C Temperature Rating

� American Bureau of Shipping (ABS): 99-BT5905-X

� UL Listed as Marine Shipboard Cable: (E111461)Other certifications pending

Termination KitsAmerCable Systems offers pre-sized and

pre-formed termination kit packages specifically for VFD cable constructions

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 31

Surface Mining CablesSurface Mining Cables

GEXOL® is a registered trademark of AmerCable Incorporated*Cable diameters are subject to a +/- 5% manufacturing tolerance

VFD Cable Ampacity RatingsEquivalent Uninsulated

Size Number Metric Size ConductorAWG/kcmil of Strands (mm2) Dia. (inches)

181614121086421

1/02/03/04/0

262313373444535646777

1111

19191919373761

133133209266342418532646777925

11101332159119242745

0.96 1.32 2.083.29 5.23 7.57

12.49 21.11 33.51 42.7954.45 70.01 85.57

108.91 132.25159.06 189.36227.23272.68325.70393.87561.94

0.0490.059 0.0740.093 0.113 0.1360.1750.2580.3240.361 0.4070.4610.510 0.5750.6540.720 0.7850.8600.9411.0291.1321.354

Strand Profile

SSiizzee NNoommiinnaall WWeeiigghhtt NNoommiinnaall WWeeiigghhtt NNoommiinnaall WWeeiigghhttAAWWGG// PPaarrtt NNoo.. DDiiaammeetteerr PPeerr PPaarrtt NNoo.. DDiiaammeetteerr PPeerr PPaarrtt NNoo.. DDiiaammeetteerr PPeerrkkccmmiill 3377--110022 IInncchheess** 11000000 FFtt.. 3377--110022 IInncchheess** 11000000 FFtt.. 3377--110022 IInncchheess** 11000000 FFtt.. SSiizzee ((AAWWGG)) 111100˚̊CC 110000˚̊CC 9955˚̊CC 9900˚̊CC 7755˚̊CC

14 -508VFD 0.540 194 -508BVFD 0.590 281 -508BSVFD 0.725 356 18 27 25 22 - 1812 -516VFD 0.590 224 -516BVFD 0.646 321 -516BSVFD 0.772 401 18 33 31 27 - 2410 -308VFD 0.633 308 -308BVFD 0.694 412 -308BSVFD 0.820 497 14 44 41 36 - 338 -309VFD 0.764 441 -309BVFD 0.820 565 -309BSVFD 0.988 702 14 56 52 48 - 436 -310VFD 0.865 570 -310BVFD 0.925 708 -310BSVFD 1.090 865 12 75 70 64 93 584 -312VFD 1.072 886 -312BVFD 1.125 1061 -312BSVFD 1.295 1243 12 99 92 85 122 792 -314VFD 1.215 1421 -314BVFD 1.271 1618 -314BSVFD 1.440 1822 10 131 122 113 159 1051 -315VFD 1.340 1517 -315BVFD 1.395 1743 -315BSVFD 1.560 1966 10 153 143 131 184 121

1/0 -316VFD 1.443 1803 -316BVFD 1.493 2027 -316BSVFD 1.666 2327 10 176 164 152 211 1452/0 -317VFD 1.572 2153 -317BVFD 1.622 2399 -317BSVFD 1.854 2840 10 201 188 175 243 1664/0 -319VFD 2.053 3463 -319BVFD 2.103 3785 -319BSVFD 2.335 4347 8 270 252 235 321 223262 -320VFD 2.193 4175 -320BVFD 2.243 4522 -320BSVFD 2.475 5120 6 315 294 267 365 254313 -321VFD 2.370 4727 -321BVFD 2.420 5104 -321BSVFD 2.652 5747 6 344 321 299 408 287373 -322VFD 2.501 5415 -322BVFD 2.551 5809 -322BSVFD 2.845 6674 6 387 361 334 451 315444 -323VFD 2.670 6707 -323BVFD 2.721 7141 -323BSVFD 3.014 8059 6 440 411 372 499 350535 -324VFD 2.972 7483 -324BVFD 3.022 2966 -324BSVFD 3.316 8981 6 498 443 418 - 390646 -326VFD 3.164 8916 -326BVFD 3.214 9428 -326BSVFD 3.508 10504 4 553 516 470 - 431777 -327VFD 3.388 10395 -327BVFD 3.438 10940 -327BSVFD 3.732 12088 4 602 562 529 473

GGrreeeenn IInnssuullaatteeddGGrroouunnddiinngg

CCoonndduuccttoorr ((xx33))

Unarmored Armored Armored &Sheathed (BS)

AAmmppaacciittyy

110°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For those

instances where cable must be double banked, the 110°C ampacities should be multiplied by 0.8.

100°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For those

instances where cable must be double banked, the 100°C ampacities should be multiplied by 0.8.

95°C Ratings Based on 4-3-4/Table 10 of the 2001 ABS MODU rules and a 45°C ambient.

90°C Ratings Based on ICEA S-75-381 Table H-1 for a single isolated cable in air with a 40°C ambient.

This ampacity is typically used for mining and other portable applications.

75°C Ratings Based on Table B.310.1 of the 2005 NEC for cables in raceway and a 30°C ambient.

Gexol is flexibleand has a low capacitance for

superior performance in VFD applications!

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961332

36-129

Drilling Mast CableTwo Conductor • 600-2000 Volts

ApplicationTiger® Brand 600-2,000 Volt two conductordrilling mast cables are recommended forinstallations where long flex life, great flexibilityand wearability are desired. Applicationsinclude power and control for drill masts andother DC applications.

Features� Suitable for continuous operating

temperatures of 90°C� Suitable for use on drills, festoons, suspended

loops and power tracks� Heavy duty jacket offers excellent protection

against abrasion, impact, heat, oil flame,ozone, alkali and acids.

� Extremely flexible stranding used for increasedflexibility and ease of installation

JacketReinforced mold-cured thermosetting rubber.Cable identification via permanent marking.

ConductorsFlexible tinned copper

InsulationEthylene-propylenerubber (EPR)

Tiger® Brand is a registered trademark of AmerCable Incorporated.

� 90°C Temperature Rating

� ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes

� Materials meet or exceed ICEA S-75-381/NEMA WC-58 and CSA Standard C22.2 #96

Control GroupConfiguration tobe specified by user

TapeNon-conducting

Ground WireFlexible tinnedcopper

ReinforcementPolypropylenereinforcing braidprovides long flex life

Ratings & Approvals

Photo courtesy Bucyrus

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 33

Surface Mining CablesSurface Mining Cables

36-129 • Drilling Mast Cable • Two Conductor • 600-2000 Volts

Primary UsageRecommendation

Blast Hole Driller

*Ampacity – is calculated with a 90°C conductor temperature and 40°C ambient air

Cable diameters and weights are subject to +/-5% manufacturing tolerance

010 1/0 266 0.080 1.52 1780 217020 2/0 323 0.080 1.65 2425 250030 3/0 418 0.080 1.77 2872 286040 4/0 532 0.080 1.92 3478 328250 250 627 0.095 2.10 4155 363350 350 888 0.095 2.36 5483 436500 500 1221 0.095 2.70 7249 524

Approx.Weightlbs. per1,000 ft.

*Ampacity90°C

Part No.36-129-

SizeAWG/kcmil

MinimumWires perConductor

NominalInsulationThickness

in.

NominalOutside

Diameter in.

Photo courtesy P&H

AmerCable TPU JacketsFor extremely abrasive environments, AmerCable’sThermoplastic Polyurethane (TPU) jacket providesthe extra-tough physical characteristics needed in the roughest mining environments.Compared to AmerCable’s standardCPE jacketing material, TPU provides:

5X more abrasion resistance

2X more tear resistance

2X more tensile strength

Blue Green Orange Yellow Red

AmerCable CPE JacketsAmerCable’s thermoset Chlorinated Polyethylenejacket provides the physical performance andstrength needed to resist wear, tear, abrasion andcompression cuts caused by everyday mining use.

This tough, durable jacket is a proven performer in mines throughout the world. AmerCable’s engineered cable construction includes a taped-core, integral fill and tandem extrusion of the jacket layers. Two-pass jackets, extruded in tandem, yield an inseparable bond between the layers. Integral filling of the cable core reduces torsion-induced damage.

(Available by Special Order)

Jacket Materials & Safety Options

Black(standard)

AmerCable’s Tiger Stripes can improve mine safety by providing easier visual circuit identification. Available on CPE round jacketed cables only.

■ Less cable damage due to accidental “run-overs” or equipment snags

■ Increased up-time due to extendedcable life

■ Faster circuit identification■ Increased safety for personnel

Tiger Stripes

Blue Green Orange Yellow RedBlack(standard)

34

Standard jacket color – black. See color options below.AmerCable’s CPE and TPU colored jacketsexperience no loss of physical propertiescompared to the standard black jackets.

These high visibility cables can improve minesafety by providingeasy circuit identification.

Up to8% Less

JacketWeight

Safety, Training, and Education

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-9613 35

Safety and maximized cable productivity areAmerCable’s top priorities for our customers. Surface or underground – 24/7 – all shifts –AmerCable’s mine-experienced field reps are ready to provide on-site cable evaluation, safe handlingtraining and innovative productivity solutions.

A few extra minutes spent in cable repair can save hours of costly downtime.

Cable Splicing TrainingOur field reps can conduct on-site training (all shifts) on the correct way to splice cables to extend their service life.

Splice Kits

(CPE or TPU)

Put the AmerCable Team to Work in Your Mine

Put the AmerCable Team to Work in Your Mine

MineCable-Safe is an investment in Safetyand Productivity that brings the knowledge and experience of our field engineers to your mine.A detailed report is provided that includes recommendations to make your cable usage safer and your mine more productive.

MineCable-SafeSafe Cable Practices

Worker Safety

Extended Cable Life

For All Surface or Underground

Mines

Surface Mining CablesSurface Mining Cables

Factory InstalledCable Assemblies

Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961336

Why Use

CableAssemblies?■ Your cable assembly,

built to your exact specifications, arrives ready for immediate use

■ Reduced prep, handlingand installation time

■ No need to maintain expensive connectorinventory or terminationkit inventory

■ Professionally assembled

■ Factory electrical testingafter termination/refurb

■ AmerCable’s on-time delivery rate and short lead times are #1 in thecable industry

Tiger Term

Lower Enhanced ReducedOverall Cost Reliability Installation Time

Factory Installed Cable Assemblies from AmerCable are professionallyassembled in our El Dorado, Arkansas manufacturing facility. Our team of experienced handlers join cables and connectors that match yourexact specifications. Our assemblies are designed to perform in your

harshest operating conditions.

Factory prepared cable assemblies or terminations are a reliable way to lower your overall cable connectivity costs through enhanced reliability, reduced handling and lower installation time.

FACTORYINSTALLED

Constructions■ 2 - 25kV■ Stress Cones & fill■ ID Labeling■ Pothead Assemblies

Applications■ Surface Mining■ Underground Mining■ Reeling

Tiger Term cables arrive ready for installation – saving you prep time and costs.

Our process involves properly removing copper shielding components and semi-conductive materials without damage to the underlying insulation. This is necessary for long-life and trouble-free operation.Tiger Term is available on any cable 5kV or larger.

350 Bailey Road • El Dorado, Arkansas USA • www. amercable.com • e-mail: [email protected] 37

Surface Mining CablesSurface Mining Cables

Molded Potheads(up to 25kV)

AmerCable has the coupler you need for immediate use upon arrival

Couplers

AmerCable is the leading manufacturer of surface and underground mining cables in the United States.

AmerCable is an ISO 9001 certified cable manufacturer that combines leading-edge technology, proven manufacturing techniques, and high quality service to deliver the finest mining cable products available.

AmerCableserves a world-wide customerbase from ourmanufacturing facility in El Dorado, Arkansas. Our professionalfield engineering and sales force work directly with customersor in partnership with a network of independent distributors toidentify and fulfill specific cable requirements.

What can you expect from AmerCable?■ High Quality Cable with an emphasis on safety

■ On-time Delivery (98%+ avg. for the last 36 months)*

■ Professional Sales, Support and Service

■ Strategic Inventory Locations

■ Short Lead Times

Automotive

AmerCable’s Mining & Industrial Cable Products

Renewable EnergyPower Cables

Factory InstalledCable Assemblies

Industrial

Underground MiningSurface Mining

350 Bailey Road • El Dorado, Arkansas USA(870) 862-4919 • (800) 643-1516 • Fax (870) 862-9613 e-mail: [email protected] • www.amercable.com

2_09© 2009, AmerCable Incorporated

El Dorado, Arkansas

Made in America* Check www.amercable.comfor our most current on time delivery record and lead times