Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
ADG-L Series
4kW/8kW/12kWOutput Power
Interfaces
Applications
OptionStandard
GPIB
Ethernet
USB
Analog
RS-232
RS-485
Programmable DC Power SupplyADG-L Series
RoHSCompliant
output powers and several Auto Range models to provide a higher
ADG-L seriesParallel Connection up to 5units
4~60kW
Programmable DC Power Supplies
Up to 1000V Output
Wide Range of Output Voltage
Auto Range Available
Deliver Higher Current at Lower Output Voltage
Intuitive Local &Remote Control
High Output Voltage and High Power Density for Renewable Energy Applications
NEW
Output Current: 0~75A or 0~150A (with parallel operation).
Output Voltage: up to 2000V(with series operation).
CV / CC / CP modes.
UVP and OTP.
Wide range of input voltage:
Home Appliance
Industrial Power Supply
Electric Vehicles
Medical Industry
Aerospace & Defense
Communication Industry
IT / SMT Production Line
Renewable Energy
Transportation
Motor & Compressor
Power Tool
6867 www.PreenPower.com www.PreenPower.com
DC Power Supply
Standard SourceOperation Limits
Auto RangeOperation Limits
NEW
operation region.
Auto Range Models
Intuitive Touch Screen and Rotary Knob
RS-485RS-232 Analog Ethernet GPIB USB
Complimentary Control Software and Various Complimentary Interfaces
Remote Sensing
SenseDUT
Sense
and provide a stable output voltage.
Newly added function: the voltage resolution of adjusting
setting.
69 www.PreenPower.com
Screen Lock Password Function
and edit parameters.
Screen Lock
12kW8kW4kW
Models141000V
660V
500V
330V
160V
Wide Voltage and Current Range
Master/Slave Parallel Operation Master
Slave
CAN BUS
Device Protection
70www.PreenPower.com
DC Power Supply
unit in different environments.
Error Log for Easy Analysis
Multiple Ways of AC Input Connection
Fast Rise Time Fast Fall Time Low Voltage Ripple Fast Transient Response
Industry-leading Performance
Program Setting Page
500W 2A 4W
Wave Page
Slew Rate Control Voltage Sag
STEPs example
STEP1 STEP2 STEP6STEP5STEP3
STEP4
Time
V
DC Pulse
Programming Sequences and Simulations
STEPs example
STEP1 STEP2 STEP6STEP5STEP3
STEP4
Time
V
High Power Density: 12kW in 3U
12kW
3U
24kW
6U
71 www.PreenPower.com
13
25
1
14
Pin Name Description
1 Vset-OVP Analog control input: 0-5 Vdc= 0-110% of full-scale output voltage
6 Vset Analog control input: 0-5Vdc= 0-100% of full-scale output voltage.
7 Vo-FB Analog output for voltage measurement.
14 Iset-OCP Analog control input: 0-5 Vdc= 0-110% of full-scale output current.
15 PS-ON Control signal for the device ON/OFF: a logic-high state (5V) is to turn ON the device; a logic-low state (0V) is to turn OFF the device.
20 Iset Analog control input: 0-5Vdc= 0-100% of full-scale output current.
21 Io-FB Analog output for current measurement.
VOLTAGE METER
-
+V CURRENT
METER
-
+A
Parallel connection (Max. 5 units)
Series connection (Max. 2 units)Multiple Connections
Analog Control (V/I)
HMI Output Calibration Function
+- DUT
+- DUT
72www.PreenPower.com
DC Power Supply
21.7kVA (33A)PF = 0.7
13kVA (20A) 8.7kVAPF = 0.99
Save 40% of input power
Input Power (Apparent Power) Comparison
01 Effectively increase real power (P) and reduce reactive power (Q) for better energy saving and operation cost.
Able to suppress peak current and power loss to have lower harmonic distortions.02
Reduce input current to have compact and high power density DC sources.03
Save more energy and lower carbon footprint for better environment.04
The ADG-L series (with PFC) v.s. Conventional DC Sources (no PFC)05
The ADG-L series is equipped with active Power Factor Corrector (PFC) to enhance input PF up to industry-leading 0.99, which helps reduce the interference on the grid.
0.99 Input Power Factor
PANEL DESCRIPTION
1 2 3 4
65 7 108 9 1511 12 13 14 16 17
1. Power Switch
3. Rotary Knob
2. Touch Screen
4. Output / Reset Button
5. DC negative output terminal
6. DC positive output terminal
8.
7. Remote Sense Connector
10. Serial and parallel switch
9. CANBUS terminal resister switch
12. Accessory power outlet
14. RS232/RS485 Interface switch
11. RS-485 terminal resister switch
13. RS232/RS485 Interface (standard)
15. Analog interface
17. Input terminals
16. Optional communication interface : USB/RS-232/RS-485(SCP)/Ethernet/GPIB
0.99
73 www.PreenPower.com
PANEL DESCRIPTION
ADG-L Series Single-Phase Output (4kW - 12kW)
Model Number DescriptionADG-L-160-25
ADG-L-160-50
ADG-L-160-75
ADG-L-330-12
ADG-L-330-24
ADG-L-330-36
ADG-L-500-24
ADG-L-660-12
ADG-L-1000-12
ADG-L-330-25-4
ADG-L-330-50-8
ADG-L-330-75-12
ADG-L-660-25-8
ADG-L-1000-25-12
ADG-L-001 Single-Phase Input Power Cord 3m ( for 4kW/8kW )
ADG-L-002 Single-Phase Input Power Cord 5m ( for 4kW/8kW )
ADG-L-003
ADG-L-004
ADG-L-005 Three-Phase Input △
ADG-L-006 Three-Phase Input △
ADG-L-007
ADG-L-008
ADG-L-013
Dimensions
Unit : mm (inch)
442 (17.4")
442 (17.4")
132(5.2")
132(5.2")
756.28 ( 29.77")
711( 27.99")
711( 27.99")
442(17.4")132
(5.2")
74www.PreenPower.com
DC Power Supply
SPECIFICATIONS
ADG-L Series DC Output (4kW - 8kW)
Model ADG-L-160-25
ADG-L-330-12
ADG-L-330-25-4
ADG-L-160-50
ADG-L-330-24
ADG-L-330-50-8
ADG-L-660-12
Output Power 4kW 4kW 4kW 8kW 8kW 8kW 8kW
INPUT
Input Voltage 1Ø 2W+G
Input Current 24A 1Ø : 48A 3Ø :42A
Input Frequency
Power Factor
OUTPUT
Voltage 0~160V 0~330V 0~330V 0~160V 0~330V 0~330V 0~660V
Current 0~25A 0~12A 0~25A 0~50A 0~24A 0~50A 0~12A
Voltage Ripple (RMS) 0.3% F.S. 0.15% F.S. 0.15% F.S. 0.3% F.S. 0.15% F.S. 0.15% F.S. 0.08% F.S.
Voltage Ripple (peak to peak) 1.6% F.S. 0.8% F.S. 0.8% F.S. 2.5% F.S. 1.6% F.S. 1.6% F.S. 0.8% F.S.
Voltage Line Regulation 0.1% F.S. 0.15% F.S. 0.03% F.S.
Voltage Load Regulation*1 0.3% F.S. 0.1% F.S. 0.3% F.S. 0.4% F.S. 0.2% F.S. 0.4% F.S. 0.05% F.S.
Current Ripple (RMS) 0.2% F.S. 0.3% F.S. 0.2% F.S. 0.2% F.S. 0.3% F.S. 0.2% F.S. 0.5% F.S.
Current Line Regulation 0.1% F.S. 0.1% F.S. 0.1% F.S. 0.1% F.S. 0.2% F.S. 0.1% F.S. 0.05% F.S. +50mA
Current Load Regulation 0.3% F.S. 0.5% F.S. 0.3% F.S. 0.2% F.S. 0.3% F.S. 0.2% F.S. 0.25% F.S.
Transient Response*2 5ms 5ms 5ms 5ms 5ms 5ms 5ms
Slew Rate*3
Rise Time 25ms 35ms 35ms 25ms 40ms 40ms 60ms
Fall Time (Full Load) 30ms 40ms 40ms 35ms 45ms 45ms 45ms
Fall Time (No Load) 10s
Programming & Measurement
Voltage Programming Accuracy 0.08%F.S.+100mV
Voltage Measurement Accuracy 0.08%F.S.+100mV 0.08%F.S.+100mV 0.08%F.S.
+100 mV
Voltage Resolution 100mV
Current Programming Accuracy 0.4%F.S.+60mA
Current Measurement Accuracy 0.3%F.S.+60mA 0.3%F.S.+60mA 0.4%F.S.
+60 mA
Current Resolution 10mA
General Specs.
Interfaces Standard: RS-485/RS-232 (Modbus) & Analog Optional: Ethernet/USB/RS-485/RS-232 (SCPI) or GPIB
Remote sense compensation 5V
Operating Temperature 0°C ~ 40°C
Storage Temperature -20°C ~ 70°C
Protections OVP.OCP.OPP.OTP.Vin OV.Vin UV. Vin LV.Phase Fail.Fan Fail
OVP Range 0~110% F.S.
OCP Range 0~110% F.S.
Dimension (HxWxD)
Weight
*1. Load changes from 0% to 100% under nominal AC input*2. Under nominal AC input, recovers to ±1% of full-scale output voltage for a 50% to 100% or 100% to 50% load change*3. Measured from 10% to 90% of the output voltage change - resistive load, typical
75 www.PreenPower.com
SPECIFICATIONS
ADG-L Series DC Output (8kW - 12kW)
Model ADG-L-660-25-8
ADG-L-160-75
ADG-L-330-36
ADG-L-330-75-12
ADG-L-500-25
ADG-L-1000-12
ADG-L-1000-25-12
Output Power 8kW 12kW 12kW 12kW 12kW 12kW 12kW
INPUT
Input Voltage
1Ø 2W+G
3Ø3W+G
3Ø4W+G
Input Current 1Ø : 48A 3Ø : 42A 3Ø : 42A
Input FrequencyPower FactorOUTPUTVoltage 0~660V 0~160V 0~330V 0~330V 0~500V 0~1000V 0~1000V
Current 0~25A 0~75A 0~36A 0~75A 0~24A 0~12A 0~25A
Voltage Ripple (rms)Voltage Ripple (peak to peak)Voltage Line RegulationVoltage Load Regulation*1
Current Ripple (rms)Current Line RegulationCurrent Load RegulationTransient Response*2
Slew Rate*3
Rise Time
Fall Time (Full Load)
Fall Time (No Load)
Programming & Measurement
Voltage Programming Accuracy
Voltage Measurement Accuracy
+100mV
Voltage Resolution 100mV
Current Programming Accuracy
Current Measurement Accuracy
+60mA
Current Resolution 10mA
General Specs.
Interfaces Standard: RS-485/RS-232 (Modbus) & Analog Option : Ethernet/USB/RS-485/RS-232 (SCPI) or GPIB
Remote sense compensationOperating Temperature 0° C ~ 40° C
Storage Temperature -20° C ~ 70° C
Protections OVP/OCP/OPP/OTP/Vin OV/Vin UV/LDC OV Vin LV/Phase Fail/Fan Fail
OVP Range 0~110% F.S.
OCP Range 0~110% F.S.
Dimension (HxWxD)Weight
*1. Load changes from 0% to 100% under nominal AC input*2. Under nominal AC input, recovers to ±1% of full-scale output voltage for a 50% to 100% or 100% to 50% load change*3. Measured from 10% to 90% of the output voltage change - resistive load, typical
76www.PreenPower.com
DC Power Supply