Upload
edward-lobello
View
214
Download
1
Embed Size (px)
DESCRIPTION
The SuperTank Rainwater/ greywater, stormwater Storage Tank by WRS.
Citation preview
Innovations In Water Storage
Water Water Reclamation Reclamation Solutions, LLCSolutions, LLC
R a inw a te r /
S t o rmw a te r
C on su l t i ng
D es i gn
S a l es
S up po r t
SUPERTANK™Rainwater/ Stormwater/ Greywater
Superior Water Storage
FEATURES
Model* Diameter
(in/cm)
Volume
(USgal/liters)
Min. Cover for
H20/HS25
Length
(ft/m)
ST072005kNP 72/ 183 5,075/ 19,211 12” 24/7.3
ST072010kNP 72/ 183 10,150/ 38,422 12” 48/14.6
ST084005kNP 84/ 214 5,181/ 19,612 12” 18/5.5
ST084010kNP 84/ 214 10,075/ 38,138 12” 35/10.7
ST096005kNP 96/ 244 5,264/ 19,926 12” 14/4.3
ST096010kNP 96/ 244 10,152/ 38,430 12” 27/8.2
ST096015kNP 96/ 244 15,040/ 56,933 12” 40/12.2
ST108010kNP 108/ 274 10,470/49,633 14” 22/6.7
ST108015kNP 108/ 274 15,226/57,637 14” 32/9.7
ST108020kNP 108/ 274 20,461/77,453 14” 43/12.8
ST120010kNP 120/305 10,556/39,959 15” 18/5.5
ST120015kNP 120/305 15,276/57,826 15” 26/7.9
ST120020kNP 120/305 19,976/75,617 15” 34/10.4
ST120025kNP 120/305 25,263/95,631 15” 43/13.1
ST138030kNP 138/351 30,303/114,709 18” 39/11.9
*Models listed are of individual tanks. Many other diameters, lengths, and volumes are available. Several op onal layouts are shown below. Call for details.
SUPERTANK™
SUPERTANK™
SUPERTANK™
Optional M
ultiple Manifold
s
WR
S Patented
Optional Equalizer Pipes
Optional Equalizer Pipes
MoreOptionsAvailable
LAYOUTOPTIONS
Lowest installed cost available
Tested Water ght
All models meet H20/HS25
100 year durability
Water NEVER contacts steel
Manufactured in most states
Simple anchoring system
Modular for unlimited capacity
Flexible fabrica on op ons
Design based on 100s of
thousands of installa ons
Power Pass Through
Floating Ball Inlet With Fine Filter
Submersible Pump With Cooling Sleeve
To Building Manway
Smoothing Inlet
Air Vent Stub
INTERIOR
EXTERIOR
Siphon OverFlow & Backflow Preventer
To Storm DrainOr BMP
InFlow From Catchment(Roof, Runoff, Etc.)
Filtered Rainwater
To Storm DrainOr BMP
>
>
>
>
>>
>
>
>
>
First Flush
Day Tank
Pump Skid
Controller
Level Sensor
Manual Bypass Valve
DomesticSupply
Check Valve
Usage Point
Air Gap
Vented Lid
Purification Device-UV-Carbon-1 micron Filter
SuperTank Water Storage Device
15°
Power Pass Through
Floating Ball Inlet With Fine Filter
Submersible Pump With Cooling Sleeve
To Building Manway
Smoothing Inlet
Air Vent Stub
INTERIOR
EXTERIOR
Siphon OverFlow & Backflow Preventer
To Storm DrainOr BMP
InFlow From Catchment(Roof, Runoff, Etc.)
Filtered Rainwater
To Storm DrainOr BMP
>
>
>
>
>>
>
>
>
>
First Flush
Day Tank
Pump Skid
Controller
Level Sensor
Manual Bypass Valve
DomesticSupply
Check Valve
Usage Point
Air Gap
Vented Lid
Purification Device-UV-Carbon-1 micron Filter
SuperTank Water Storage Device
15°
Rainwater Harvesting System Schematic Component Diagram
1.0 Scope
This specifica on covers the manufacture and installa on of the SuperTank™ for the purposes of water storage for reuse, rainwater harves ng, or storm water deten on/ reten on.
2.0 Material
The SuperTank™ main body shall be constructed of polymer coated steel which conforms to the applicable requirements of AASHTO M246 and ASTM A742. Bulkheads, flanges, stubs, welds and all other exposed steel shall either be powder coated with polyester fusion bonded coa ng or patch compounds recommended by Dow® Chemical for their Trenchcoat™ polymer film.
3.0 Manufacture
The SuperTank™ main body shall be manufactured in accordance with the applicable requirements of AASHTO M245 and ASTM A762. Tank size and layout shall be as shown on the project plans. Gauge, corruga on, fabrica on, and lay schedule shall be as determined by a qualified WRS representa ve based upon site condi ons as provided by the design engineer and applying structural design guidelines of ASTM A796 and AASHTO M36. Fi ngs shall be manufactured in accordance with ASTM A998.
The SuperTank™ shall be fabricated according to WRS quality control program for water ghtness, structural integrity, corrosion resistance, and workmanship.
3.1 Joints
All joints greater than 48” in diameter, when required for modular SuperTanks, shall be flange type connec ons as designed by WRS. Joint sealants or gaskets shall be per WRS quality control program. Tank fabricator shall shop assemble joints and match mark both the flanges and SuperTank™ units to ensure ease of installa on and quality joints prior to shipment.
3.2 Anchor Tie Downs No Wrench helical anchor e downs shall be
supplied based upon site condi ons and tank size or as shown on the project plans. Anchor e downs shall u lize 4” nylon straps for a achment to pipe and be manufactured by Hughes Power Systems or approved equal.
4.0 Handling and Installa on Handling shall be according to WRS instruc ons. Care shall be taken at all mes to protect polymeric coa ngs from
damage. If metal is exposed at any me during the installa on or handling process, contact WRS or qualified representa ve to obtain instruc ons for repair. Installa on shall be according to WRS published installa on instruc ons and AASHTO Standard Specifica ons for Highway Bridges, Sec on 26, Division II or ASTM A798. Where WRS published installa on is the higher standard, it supersedes the ASTM and AASHTO standards. Contractor must follow all OSHA codes for safe construc on prac ces as well as local applicable regula ons.
4.1 Construc on Loads Installer shall follow NCSPA or
manufacturer guidelines for construc on loads.
5.0 Submi als Installer shall provide _____copies of shop
drawings, WRS installa on guide, and product literature to the design engineer for approval before fabrica on can begin.
6.0 Alternates Alternates to the SuperTank™ must be sub‐
mi ed for approval to the consul ng architect or engineer of record for approval at least 10 days before the bid date.
SUPERTANK™ Specification
Informa on contained herein is for general use only. Suitability for a par cular applica on should be determined by a professional engineer. This
publica on is not intended to be used for the purposes of warranty including but not limited to the implied warranty of merchantability or fitness for a
par cular purpose.
© Water Reclama on Solu ons, LLC 2012
Phone:
910‐340‐0552
Em
ail: Sales@
wrs‐so
luons.n
et