29

SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

Embed Size (px)

Citation preview

Page 1: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB
Page 2: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

SUMMER TRAINING REPORT HELD AT

BSNL

Page 3: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

INDEX

1. COMPANY PROFILE

2. INTRODUCTION

3. ABOUT THE EXCHANGE

4. MDF

>TYPES OF FAULTS

>PROTECTIVE DEVICES

5. OCB

6. GSM

7. MEDIA

8. PROCEDURE FOR HANDLING COMPLAINTS

Page 4: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

INTRODUCTION

Today, BSNL is the No. 1 telecommunication company and the largest public sector undertaking of India and its responsibilities includes improvement of the already impeccable quality of telecom services, expansion of telecom services in all villages and instilling confidence among its customers.

EXCHANGE:

Equipment which effects interconnected of telephones is known as switching equipment. The switching centre, which houses the terminating and switching equipment is called telephone exchange.

Page 5: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

EXCHANGE LAYOUT

 

Typical exchange consist of :

Switch Room Operations and Maintenance (OMC) RoomInput Output processor (IOP) Room Power Plant Room Battery Room Main Distribution Frame (MDF) Room 

Page 6: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

ABOUT THE EXCHANGE

1. All telephone subscribers are served by automatic exchanges.

2. Today’s automatic exchanges uses a pair of computers.

One, running the program that provides services.

Second, monitoring the operation of the first, ready to take over in a few seconds in the event of equipment failure.

Various exchanges present in BSNL are:

> C-DOT> OCB> EWSD

Page 7: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

MAIN SECTIONS OF EXCHANGE:

There are three components of exchange: MDF Power plant Switching Room.

Page 8: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

MAIN DISTRIBUTION FRAME (M.D.F) :

INTRODUCTION:

- MDF means Main Distribution Frame. Local cable contact at MDF . - All types of cables out to the door contact connection at MDF .

Page 9: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

THE MAIN PARTS OF THE POWER ROOM ARE:

1. BATTERIES

2. UPS (UNINTERRUPTED POWER SUPPLY)

3. CHARGING - DISCHARGING UNIT

4. INVERTER AND CONVERTER UNIT:

POWER PLANT :

Page 10: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

SWITCHING ROOM :

Switch room consists of BM and CM cabinets mounted in standard switch.

These cabinets are fastened to a switch Room and interconnected by cables.

Page 11: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

.

MAIN DISTRIBUTION FRAME

> The primary function of MDF is to remove fault. It is also known as Fault Remove Section. > The telephone numbers are also disconnected in the MDF because of some specific reason.

ORGANISATION OF THE MDF

• Vertical side• Horizontal side

Page 12: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

VERTICAL SIDE 

RACK: -On the rack, the tags are situated. One rack is having eight tags. The counting is done from up (0) to down (7).

TAGS: -Each rack consists of eight tags.1 tag = 4 core1 core = 4 bunch1 bunch = 2 line

N.E.:-The word NE stands for the ‘NUMBER OF EQUIPMENT’.It is used for testing number and

WEDGE: Wedge is used as a device for checking the ring. Wedge is placed in jack strips, which is connected to telephone for checking.

Page 13: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

HORIZONTAL SIDE:

The horizontal side connected to the underground cable. This cable is having 100 pairs. These pair is distributed when we allot the telephone number to the subscriber.

Horizontal side is again subdivided in two parts:

One part is connected with the vertical side. Another with the subscriber line by using 100 pair underground cable.

Page 14: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

CONSTRUCTION OF M.D.F:-

Main distribution frame is mainly divided in two parts.

(1) Vertical Side or Line side.

(2) LEN side or Exchange side.

Page 15: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

VERTICAL SIDE:

All the part from vertical side to the subscriber are generally called outdoor section.:

1. One vertical has 10 tag blocks.

2. Each tag block has 10 rows and each row has 10 tags. So each tag block has 100 tags.

3. Connection between vertical side & subscribers are provided by jelly filled cables.

4. These wires are first terminated in cabinet box, then according to requirements the group of the wires (e.g. 200 wires, 100 wires etc.) is terminated in pillar box

Page 16: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

LEN SIDE:

• All the parts from LEN to the exchange is called indoor section.

• The connection of subscriber from exchange is terminated on this side of MDF.

• In 1 tag block there are 128 tags. Each tag block is divided in 4 segments. That is 0, 1,2 & 3 and in each segments.

Page 17: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

. DIFFERENT TYPES OF FAULTS:-

LOOP FAULT:-IF TWO WIRES ARE JOINED TOGETHER BECAUSE OF IMPROPER CONNECTION,STORMING AIR ETC.

EARTH FAULT:-IF TWO WIRES GET SCRAPE AT SOME PLACES AND IF THIS WIRE COMES INCONTACT WITH TREE, PILLAR OR ANY METAL OBJECTS THEN THIS TYPE OF FAULT OCCURS.

CABLE FAULT:-FOR OUTDOOR CONNECTIONS, JELLY FILLED WIRES ARE USED WHICH ARE AFFECTED BY NATURAL CAUSES SUCH AS RAIN, EARTHQUAKE ETC. AT SUCH TIME THIS FAULT OCCURS.

DISCONNECT FAULT:-THIS TYPE OF FAULT OCCURS DUE TO THE BREAKING OF WIRES BETWEEN THE VERTICAL SIDE & LEN SIDE.

Page 18: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

PROTECTIVE DEVICES USED IN M.D.F.

Fuses

Gas Discharge Tube(G.D Tube)

Insertion Tool

Wires

Page 19: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

OCB

The new switching systems are based on Stored Program Control concept. The call processing programmers are distributed over different control organs of the system and are stored in ROM/RAM of the units Processor in the control units .

Features:

It is a digital switching system. The system supports all the existing signaling system .The system has ‘auto recovery’ feature. When a serious fault occur in control unit, it gives a message to SMM (operation & maintenance unit).

Page 20: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

•GLOBAL SYSTEM FOR MOBILE COMMUNICATION (GSM)

Global system for mobile communication (GSM) is a globally accepted standard for digital cellular communication. GSM is the name of a standardization group established in 1982 to create a common European mobile telephone standard

GSM is a cellular network which means that mobile phones connect to it by searching for cells in the immediate vicinity. GSM operates in the 900 MHz frequency band.

Page 21: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

THERE ARE FIVE DIFFERENT CELL SIZES IN A GSM NETWORK-

Macro Cells Micro Cells Pico Cells Femto Cells Umbrella Cells

Page 22: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

GSM : (SYSTEM ARCHITECHTURE)

This system structured hierarchically as shown:  It consist of one administrative region, which is

assigned to a MSC(Mobile Switching Center). Each administrative Region is made up of atleast

one Location Area(LA). LA is also called the visited area.

An LA consists of several cell groups. Each cell group is assigned to a base station

controller(BSC). Cells of one BSC may belong to different LA’s.

Page 23: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

GSM : (SYSTEM ARCHITECHTURE)

Page 24: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

BASIC BUILDING BLOCKS:

Mobile Station (MS)

Base Station (BS)

Mobile services Switching Center (MSC)

Databases

Operation and Maintenance Center (OMC)

Page 25: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

SYSTEM CAPACITY

Shannon’s Theory predicts the maximum amount of information that can be transmitted over a channel with given BW & SNR.

The optimum usage of given BW is obtained when the signal are noise – like & min SNR.

Hence for increased capacity the choice is CDMA.

Page 26: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

MEDIA : -

1.Carrier system

2. Co-axial Cable

3. Optical Fiber Cable(OFC).

4. Satellite.

Page 27: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

PROCEDURE FOR HANDLING SUBSCRIBER COMPLAINTS

Telephone Dead:

Case--I Problem concerns a particular subscriber.

Case-II Quit a few numbers of telephone reported dead:

Telephone Held-Up ( No Dial Tone ):

Page 28: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

> PERMANENT RING

> PERMANENT DIAL TONE

> PERMANENT BUSY TONE

> PERMANENT RING – TRIP

 > SPEECH QUALITY POOR  > WRONG NUMBERS  > ONE WAY SPEECH

> RINGER CADENCE

Page 29: SUMMER TRAINING REPORT H ELD A T BSNL INDEX 1. COMPANY PROFILE 2. INTRODUCTION 3. ABOUT THE EXCHANGE 4. MDF >TYPES OF FAULTS >PROTECTIVE DEVICES 5. OCB

THANK YOU