OJ41T0RONT0 Michael Pacholok Purchasing and Maledals Management Division Jackie Kennedy Chief Purchasing Officer City Hall, 18th Floor, West Tower Acting Manager 1D Queen Street West Professional Seces Toronto, Ontaho MSH 2N2 May 8, 2018 Posted via PDF 3 pages + Attachment ADDENDUM NO.2 REQUEST FOR TENDER NO. 12-2018 CONTRACT NO. 1 8TW-CTS-O7CWD FOR: WATERMAIN CIPP LINING IN NORTH YORK DISTRICT, WARDS 30, 31, AND 32. REVISED CLOSING DATE: MAY 14. 2018. NOON (Local Time) Please refer to the above Request for Tender (RFT) document in your possession and be advised of the following: CLOSING DATE i) The tender closing date has been extended from noon (local time) May 10th, 2018 to noon (local time) May 14th, 2018. II. SERVICE CARD SUMMARY i) Delete the water service summary for Drawing No. 18104- Gould Street provided in Addendum 1 and replaced with the revised summary appended at to this Addendum. III. QUESTIONS & ANSWERS Q1. According to Section 4A.2.5, all taps on services under 50mm are to be performed while the watermain is live and under the supervision of a level one operator. Will the City permit the tapping of the watermain while the watermain is connected to the bypass and not under pressure? Al. No, small diameter services shall be installed by wet tapping method. Q2. In section 3, line item #15, two field offices are required. Could the City provide a preferred designated location of where they want the field office to be installed? A2. The location of the field offices will depend primarily on the project sequencing plan and in consultation with the Work Zone Traffic Coordinator. At this time, the City anticipates the offices would be installed on sites 18303 [Finch Ave EJ, and 18313 [Lesmill Rd / Duncan Mill Rdj; but this is subject to vary. Q3. According to section 4A.10.SP1,Temporary Watermain Bypass, the contract states that lump sum price shall include large services to be directly connected. Can the City please specify what services require a direct connection? If not, how will the contractor be 1 of 4

summary - Toronto · A7. The area to be lined (Lesmill Rd and Duncan Mill Rd) falls within PD4. The 300 watermain on York Mills Rd operates within the lower pressure district PD3E

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: summary - Toronto · A7. The area to be lined (Lesmill Rd and Duncan Mill Rd) falls within PD4. The 300 watermain on York Mills Rd operates within the lower pressure district PD3E

OJ41T0RONT0Michael Pacholok Purchasing and Maledals Management Division Jackie KennedyChief Purchasing Officer City Hall, 18th Floor, West Tower Acting Manager

1D Queen Street West Professional SecesToronto, Ontaho MSH 2N2

May 8, 2018 Posted via PDF — 3 pages + Attachment

ADDENDUM NO.2REQUEST FOR TENDER NO. 12-2018CONTRACT NO. 1 8TW-CTS-O7CWD

FOR: WATERMAIN CIPP LINING IN NORTH YORK DISTRICT, WARDS 30, 31, AND 32.

REVISED CLOSING DATE: MAY 14. 2018. NOON (Local Time)

Please refer to the above Request for Tender (RFT) document in your possession and be advisedof the following:

CLOSING DATE

i) The tender closing date has been extended from noon (local time) May 10th, 2018 to noon(local time) May 14th, 2018.

II. SERVICE CARD SUMMARY

i) Delete the water service summary for Drawing No. 18104- Gould Street provided inAddendum 1 and replaced with the revised summary appended at to this Addendum.

III. QUESTIONS & ANSWERS

Q1. According to Section 4A.2.5, all taps on services under 50mm are to be performed whilethe watermain is live and under the supervision of a level one operator. Will the Citypermit the tapping of the watermain while the watermain is connected to the bypass andnot under pressure?

Al. No, small diameter services shall be installed by wet tapping method.

Q2. In section 3, line item #15, two field offices are required. Could the City provide apreferred designated location of where they want the field office to be installed?

A2. The location of the field offices will depend primarily on the project sequencing plan andin consultation with the Work Zone Traffic Coordinator. At this time, the City anticipatesthe offices would be installed on sites 18303 [Finch Ave EJ, and 18313 [Lesmill Rd /Duncan Mill Rdj; but this is subject to vary.

Q3. According to section 4A.10.SP1,Temporary Watermain Bypass, the contract states thatlump sum price shall include large services to be directly connected. Can the City pleasespecify what services require a direct connection? If not, how will the contractor be

1 of 4

Page 2: summary - Toronto · A7. The area to be lined (Lesmill Rd and Duncan Mill Rd) falls within PD4. The 300 watermain on York Mills Rd operates within the lower pressure district PD3E

compensated for a large water service that will require an excavation on the water maintee and at the street line (including sheathed and shored, temporarily connected to thebypass system and then full restored).

A3. As per SP1, temporary service connections shall include the cost of excavation. Noadditional information will be provided at this time.

Q4. Section 4A. 10. SP1 states that available water card record information has beencompiled to identify water service information for properties fronting the Work. Theavailable water service information is presented in the Contract Documents but may notinclude all water services, and may not be accurate. The Contractor shall investigate thelocation and size of all existing water services and ensure that the temporary watersupply system provides a temporary service for all existing services with adequatesupply. Without accurate information the contractor will not be able to determine the sizeor location of each water service. This information is required to determine where theproper connection to the property is to be made. Could further information be providedon the water services that are missing in order to insure all buildings received the properbypass connection?

A4. No further information will be provided at this time.

Q5. According to Section 4A.1 1 .SP2 the contract states that where liner deficiencies,obstructed water services, or improperly drilled water services have been identified, theContractor shall excavate, cut out the section of impacted pipe, and replace with a fillerpiece and couplings. The Contractor shall then conduct and submit an additional V3CCfl/ inspection for review. All costs associated with this Work shall be borne by theContractor. To provide this V3, access pits will need to remain open for several weeks,delaying the restoration from occurring. In addition, certain scenarios may occur wherethe watermain will be live, therefore requiring an additional water shutdown to occur. Willthe City except alternative methods that can be used in order confirm the work has beencompleted in order to expedite the work and prevent additional water oHs fromoccurring?

A5. The City, in its sole discretion, may accept on a case-by-case basis alternative evidencein lieu of a repeated V3 inspection.

Q6. According to Section 4A.13, SP4, it states that limit valves are valves at the boundary ofa refined watermain. Limit valves will be closed and live on one side during the refiningprocess. The Contractor shall replace any limit valves found to be non-operational ordefective. Could the City provide a list of all valves that are required for replacement?(lead joint valves, valves inside chambers)?

A6. If valves are found to be non-operational or defective during construction then they are tobe replaced. No list of valves will be provided at this time. The Contractor shall installnew valves on the watermain as shown on the Contract Drawings.

2 2 of 4

Page 3: summary - Toronto · A7. The area to be lined (Lesmill Rd and Duncan Mill Rd) falls within PD4. The 300 watermain on York Mills Rd operates within the lower pressure district PD3E

Q7. In Section 4A.20, SP-1 1, critical valves, it states that Lesmill York Mills Road is apressure district boundary. Could the City please provide more information (such asoperating pressure on either side of the valve) on the pressure district boundary as thisinformation is important to designing a temporary watermain bypass.

A7. The area to be lined (Lesmill Rd and Duncan Mill Rd) falls within PD4. The 300watermain on York Mills Rd operates within the lower pressure district PD3E. Thehydrants on York Mills Rd therefore cannot be used to supply the temporary bypasssystem. The nearest potential supply hydrant operating within P04 is HY4025968 at thenorthwest corner of Don Mills Rd and York Mills Rd. Pressure District Boundary valveWV4026981 on York Mills Rd must remain closed.

Q8. According to the As Build Records section, a GPS location is required for each hydrant,valve, bend and fitting. Could the City please clarify if this includes each main stop (newand existing)? In addition, would the City consider providing a pay item for each Recordof Alternation created?

A8. Yes, locations of new and existing main stops are required. Records of Alteration arepart of the As-Built Records; no separate payment shall be made.

Should you have any questions regarding this addendum contact Christine Sze-Louie, SeniorCorporate Buyer at (416) 397-4803 or by email [email protected].

Please attach this addendum to your RFT document and be governed accordingly. Tenderersare to acknowledge receipt of all addenda in their Tender in the space provided on the TenderCover Page as per Section 1 — Tender Process Terms and Conditions, item 9 of the RFTdocument. All other aspects of the RFT remain the same.

Yours trujy, /

Ja4kfe Kenhedy, çUig’1ManagerProfessional Services

3 3 of 4

Page 4: summary - Toronto · A7. The area to be lined (Lesmill Rd and Duncan Mill Rd) falls within PD4. The 300 watermain on York Mills Rd operates within the lower pressure district PD3E

Street

NumberStreet Name

Primary Service

Card

Other Service

Cards

Domestic

Size (mm)

Domestic

Material

Domestic

Installation

Year

Fire Service

Size (mm)

Fire Service

Material

Fire Service

Installation

Year

Notes

1 to 9 Gould St FT_W003780 50 Also 335 Yonge St

335 Yonge St FT_D0136576 FT_D0136575 50 1972 150 1974 Serviced from Yonge St

2 to 4 Gould St FT_W003790 100 Also 341 Yonge St

341 Yonge St W_S05738 150 PVC 2013 200 PVC 2013 Serviced from Yonge St

11 to 23 Gould St FT_W003787 100 1911 Serviced from Victoria St

16 Gould StAlso 350 Victoria St. Serviced

from Victoria St.

17 Gould St FT_W003788 200 DI 1988Also 300 Victoria St. Serviced

from Victoria St

18 Gould St FT_W003789 13 Abandoned.

25 Gould St No connection on Gould St

33 Gould StConnection to Gould St. Size

Unknown.

40 Gould St FT_W003791 150 CI Serviced from Gould St

60 Gould StSecond large diameter service for

this building. Size unkown.

41 Gould St FT_W003792 150 Connection location unkown

45 Gould St FT_W003793 N/A Also 137 Bond St

50 Gould St FT_W003797 100 Valve on Church St

55 Gould St EY004458 150 DI 2004 Connection to Gould St

57 Gould St FT_W003798 13May be abandoned. Assume

connection on Gould.

59 to 61 Gould St FT_W003799 100 1961 Connection location unkown

63 Gould St FT_W003800 100 1977Also 322 Church St. Connection

location unkown

64 Gould St FT_W003803 25Also 325 Church St. Connection

on Church St

80 Gould St Connection on Church St.

83 Gould St Connection location unkown

88 Gould St FT_W003804 13 Valve on Dalhousie St

91 Gould St FT_W003813 75 Valve on Dalhousie St

245 Church St Connection on Church St.

140 Mutual St Connection location unknown

150 Mutual St Connection location unkown

18104 - Gould St

ADDENDUM 218TW-CTS-07CWD