1 A D 8 B C 2 3 4 5 6 7 A.2 C.8 2.2 6.8 VAN VAN V A N VAN VAN CENTERLINE TO FACE OF PANEL 55'-0" SUITE 113 01 B.O. CEILING FINISHED FLOOR NOTE 1 01B NO SOUND BATT INSULATION 4 7/8" 5/8" GWB 3" SOUND BATT NOTE 2 A100 A3 2'-2" OFFICE 103 OFFICE 102 WAITING 100 CONFERENCE 104 WOMEN 105 INSTRUCTION 101 MEN 107 ELECTRICAL 106 24'-7 7/8" +/- 11'-0" 3 5/8" 11'-0" 3 5/8" 7'-0" 14'-0" 3 5/8" 19'-0" 3 5/8" 14'-0" 10'-0" existing floor receptacles to remain (8 total) existing ceramic tile entry walk-off to remain copy/print WD 02 WD 02 WD 02 WD 03 8" 8" 5'-0" 1' -5" 01B 01B 01 01 01 01 01 98.00° NOTE 5 FT FT FT NOTE 5 NOTE 5 WD 04 EXISTING ELEC. PANEL EXISTING DOOR EXISTING DOOR WOMEN 105 ELECTRICAL 106 MEN 107 CORRIDOR 108 INSTRUCTION 101 PRINTER/CO PIER BY OWNER 01 01 01 01 01B 01B 01B 01 01 60" wide 59"deep 4'-0" 7'-8" 4'-6" 1' -5" 01 01B 60" wide 59"deep 6" 1'-0" CLEAR NOTE 5 1'-8" 2'-2" EXTG GRAB BAR GRAB BAR 36" NOTE 6 GRAB BAR 42" GRAB BAR 36" NOTE 6 3'-6" 4'-0" 98.00° 1'-6" 9' - 0" 10' - 4" EXISTING CEILING NEW CEILING EXTG CEILING EXTG CEILING NOTE 7 NOTE 8 CODE SUMMARY - 2012 IBC Non-Structural Building Code Information General Summary: Sylvan Learning Center Tenant Improvement Business Use: Training and skill development not within a school or academic program. The existing building is designed to meet Type II-B, Non-combustible Fully Sprinkled Project Location: 3900 Yankee Hill Road, Suite 113 Lincoln, NE 68516 Construction Type: II-B Unprotected Fully Sprinkled Occupancy Classification: Business (B) Area of Tenant: 2,593 SF Gross Lease Area Occupant Load: 25 OCCUPANTS max. Exit Access 1 Exit Required (< 50 Occ.) & Egress Travel Distance: 100 ft max. Plumbing Fixture Count: 1 Private Mens (City Plumbing Code 1 Private Womens Exception 24.10.140) (with 25 Max. Occupants) DEMO 1 DEMO 1 DEMO 2 DEMO 3 6'-0" 2'-8" 4'-0" WD 02 NOTE 3 *FT *ADJACENT TO OFFICE DOORS (NOTED IN PLAN) 6'-8" WD 01 6'-8" NOTE 5 8'-0" 4'-0" 2'-8" WD 03 NOTE 3 EQ 2 1/2" EQ MIN. 1'-7" 2'-0" 6" EDGE RIM 1'-6" TOP RIM FEMININE NAPKIN DISPOSAL AT WOMENS TOILETS ONLY TOILET PAPER DISPENSER 3'-6" 1'-0" GRAB BAR 3'-0" 6" 1'-6" 2'-10" ACCESSIBLE FIXTURES AND ACCESSORIES MIN. 1'-0" MIN. 1'-0" 2' - 8" MAX. 3' - 2" MIN. MAX. 1'-0" 24" MINIMUM 3'-6" PREFERRED 2'-8" MAX. 3'-2" MIN. GRAB BAR REINFORCEMENT LOCATION AT WATER CLOSETS 1/4" 3/4" SILL BASE HEAD (JAMB SIM.) 1/4" 3/4" 2 1/2" 102'-8" 106'-8" 4 7/8" 1 1/4" 1 1/4" 2 1/2" 2 1/2" 2 1/2" 1/4" 2 1/2" 1/4" 5/16" 4 1/4" 5/16" VERTICAL MULLION PAINTED WOOD STOP & TRIM TYP. (BLOCKING REQ'D) PAINTED WOOD CASING TYP. (BLOCKING REQ'D) PAINTED WOOD BASE TYP. (BLOCKING REQ'D) 3 1/2" WD 04 4'-0" 2'-10" MAX. 2' - 5" MIN. 2'-3" MIN. 1'-5" MIN. 3'-6" 3'-4" MAX. LAVATORY SOAP DISPENSER MIRROR PAPER TOWEL DISPENSER STANDARD AND ACCESSIBLE FIXTURES AND ACCESSORIES MECHANICAL / ELECTRICAL ENGINEER Olsson Associates 601 P Street, Suite 200 Lincoln, NE 68508 402.474.6311 7 0 0 Q S t . L i n c o l n , N E 6 8 5 0 8 T : 4 0 2 4 7 6 7 3 3 1 F : 4 0 2 4 7 6 8 3 4 1 SHA PROJECT NO. D E S I G N A R C H I T E C T : P R O J E C T A R C H I T E C T : D R A W N B Y : I S S U E D : R E V I S I O N S : Copyright SINCLAIR HILLE ARCHITECTS C PROJECT CONSULTANTS 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H J K L M 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H J K L M Yankee Ridge Commercial Center Sylvan Learning Center - SUITE 113 Coordinating Professional 1/18/2017 8:41:28 AM N:\CURRENT PROJECTS\16075 Yankee Ridge Sylvan Learning Center TI\Drawing Files\1_Revit Model\16075_Architectural_Sylvan TI_2015.rvt New Overall Tenant Plan, & Demolition Plan 16075 DEL A100 - LAB 01/11/2017 STANDARD HEIGHTS F1 SCALE: 1" = 30'-0" SHELL BUILDING KEYPLAN J1 WOOD FRAME SECTION AND DETAILS SHEET A100 SHEET SPECIFIC NOTES NOTE 1 NEW PARTITION WALL FROM FLOOR TO UNDERSIDE OF EXISTING DROPPED CEILING GRID (BRACE AS REQUIRED) CONSTRUCTED OF 3-5/8", 20 GA. STUDS AT 16" O.C. W/ SOUND BATT FIBER INSULATION AND 1-LAYER 5/8" GYPSUM BOARD EACH SIDE. INSTALL 5/8" MOISTURE RESISTANT GYPSUM BOARD AT RESTROOM SIDE OF WALL, TYPICAL. TAPE, SAND, AND PAINT WALL FROM FLOOR TO CEILING - COORDINATE FINISH PAINT COLOR(S) WITH FUTURE TENANT AND LEASING AGENT. NOTE 2 BRACE TO STRUCTURE AS NEEDED. NOTE 3 NEW INTERIOR WOOD WINDOW & CASING - PAINTED (SEE DETAIL A1/A100) WITH 1/4" CLEAR GLAZING. PROVIDE FULLY TEMPERED GLAZING WHERE REQUIRED BY CODE - COORDINATE FINISH PAINT COLOR WITH TENANT AND LEASING AGENT. NOTE 5 NEW 3'-0" x 6'-8" x 1-3/8" SOLID CORE 6-PANEL DOOR (MATCH EXISTING DOORS IN SPACE - CONFIRM SIZE, TEXTURE, AND STYLE). COORDINATE FINISH PAINT COLOR WITH TENANT AND LEASING AGENT. NOTE 6 PROVIDE TOILET ACCESSORIES TYPICAL: SINGLE ROLL TOILET TISSUE DISPENSER, WALL MOUNT PAPER TOWEL DISPENSER. NOTE 7 PROVIDE NEW GYPSUM CEILING. EXTEND AND MATCH EXISTING FRAMING AND CEILING FINISH OF CURRENT GYPSUM CEILING AREAS. NOTE 8 EXISTING PANEL CEILING TO REMAIN. RE-USE EXISTING FIXTURES AS INDICATED IN DRAWINGS (SEE MECHANICAL & ELECTRICAL). SCALE: 3/4" = 1'-0" WALL TYPES D1 GENERAL NOTES 1 ALL DIMENSIONS ARE REFERENCED FROM FACE OF FRAMING STUD, FACE OF MASONRY, FACE OF CAST-IN-PLACE CONCRETE OR FACE OF PRECAST UNLESS NOTED OTHERWISE. 2 WHERE REMOVAL OF ITEMS LEAVES A HOLE OR DAMAGED SURFACE THAT WILL BE EXPOSED IN FINISHED WORK, PATCH AND REPAIR DAMAGE TO MATCH ADJACENT FINISHED SURFACE. 3 COORDINATE WORK OF ALL OTHER TRADES WITH YOUR TRADE PRIOR TO STARTING ANY CONSTRUCTION. 4 FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF ANY NEW CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 5 GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE WORK OF ALL TRADES. 6 CONSULT ARCHITECT / STRUCTURAL ENGINEER FOR ANY AND ALL LOCATIONS WHERE UNFORSEEN OR UNUSUAL STRUCTURAL CONDITIONS EXIST. 7 DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. VERIFY ALL DIMENSIONS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT IMMEDIATELY. 8 PROVIDE BLOCKING IN WALLS FOR ALL BASE AND WALL CABINETS, TELEVISIONS, WALL HUNG EQUIPMENT, BATH ACCESSORIES AND WALL APPLIED DOOR HARDWARE. 9 PLUMBING / ELECTRICAL TRADES SHALL COORDINATE THEIR WORK WITH FOUNDATIONS AS REQUIRED IN MECHANICAL / ELECTRICAL SPECIFICATIONS AND NOTES. PENETRATIONS / SLEEVES SHALL BE COORDINATED WITH ARCHITECT AND STRUCTURAL ENGINEER. VICINITY MAP North Yankee Hill Rd S. 40th Street S. 37th St. Grainger Pkwy PROJECT LOCATION GENERAL DEMOLITION NOTES 8. REPAIR OR REPLACE ANY EXISTING CONSTRUCTION AND FINISHES SCHEDULED TO REMAIN WHICH ARE DAMAGED DURING DEMOLITION OPERATIONS. DAMAGED CONSTRUCTION AND FINISHES SCHEDULED TO REMAIN SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING ADJACENT CONSTRUCTION. 9. UNLESS NOTED OTHERWISE, WHERE EXISTING FIXTURES, ASSEMBLIES OR EQUIPMENT ARE REMOVED, REMOVE AND CAP ASSOCIATED SERVICES IN A CONCEALED LOCATION AND AS REQUIRED FOR NEW WORK. REMOVE (OR REMOVE AND SALVAGE) ASSOCIATED CARRIERS AND MOUNTING DEVICES AS REQUIRED FOR REINSTALLATION OR NEW WORK. REFER TO AND COORDINATE WITH MECHANICAL AND ELECTRICAL. 10. SAW CUTTING OF CONCRETE BEYOND THE DIMENSIONS OF THE PLANNED OPENING IS PROHIBITED. 11. DEMOLITION DRAWINGS ONLY INDICATE PRIMARY DEMOLITION WORK. ALL ADDITIONAL INCIDENTAL DEMOLITION REQUIRED TO COMPLETE WORK IS TO BE INCLUDED AS PART OF THE OVERALL DEMOLITION EFFORT WITH NO ADDITIONAL COSTS BEING ASSESSED TO THE OWNER. 12. REPAIR AND PREPARE ALL EXISTING SURFACES ADJACENT TO DEMOLITION ITEMS AS REQUIRED TO RECEIVE NEW FINISHES. 13. THE OWNER RETAINS THE FIRST RIGHT OF SALVAGE FOR ALL ASSEMBLIES AND EQUIPMENT. IF OWNER DECLINES, THE CONTRACTOR SHALL REMOVE ITEMS FROM THE PREMISES AND DISPOSE OF PROPRLY. VERIFY OWNER'S INTENT PRIOR TO REMOVAL OR DEMOLITION. 14. REMOVE AND SALVAGE MOUNTED ITEMS AS REQUIRED BY THE WORK. REINSTALL UNLESS DIRECTED OTHERWISE BY OWNER. 15. COORDINATE RELOCATION AND STORAGE OF ANY EXISTING FURNISHINGS & EQUIPMENT (SHOWN AND NOT SHOWN) WITH OWNER PRIOR TO COMMENCEMENT OF DEMOLITION ACTIVITIES GENERAL DEMOLITION NOTES 1. THE EXISTING INFORMATION SHOWN ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED INSOFAR AS BUILDING CONSTRUCTION AND EXISTING CONDITIONS ARE CONCERNED. EXACT LOCATIONS, MEASUREMENTS, DISTANCES, LEVELS, ETC. WILL BE GOVERNED BY CONDITIONS AT THE JOB SITE. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS WHICH AFFECT WORK TO BE PERFORMED AS PART OF THIS PROJECT PRIOR TO ANY NEW CONSTRUCTION OR MATERIAL FABRICATION. 2. REFER TO FLOOR PLANS FOR NEW CONSTRUCTION REQUIREMENTS. COORDINATE ALL DEMOLITION WORK WITH ALL NEW CONSTRUCTION INDICATED. 3. ALL BOLD, DASHED LINES INDICATE EXISTING CONSTRUCTION TO BE REMOVED UNLESS NOTED OTHERWISE. 4. THESE PLANS INDICATE MAJOR ITEMS OF DEMOLITION IN THE PROJECT AND ARE NOT INTENDED TO INDICATE ALL DEMOLITION REQUIRED TO COMPLETE THE WORK. ADDITIONAL DEMOLITION MAY BE REQUIRED OF THE CONTRACTOR IN ORDER TO COMPLETE NEW CONSTRUCTION. 5. CONTRACTOR IS TO PROVIDE OPENINGS IN WALLS AS REQUIRED BY ANY NEW DUCTWORK, CONDUIT OR OTHER UTILITIES. REFER TO MECHANICAL AND ELECTRICAL PLANS FOR SIZE AND LOCATION OF POTENTIAL OPENINGS NOT SPECIFICIALLY INDICATED AS PART OF THE DEMOLITION DRAWINGS. 6. CONTRACTOR SHALL FILL ALL OPENINGS IN EXISTING FLOOR SLABS, WALLS AND CEILINGS LEFT BY THE REMOVAL OF EXISTING DUCTWORK, CONDUIT AND OTHER UTILITIES. FILL HOLES SO AS TO MATCH THE EXISTING ADJACENT CONSTRUCTION MATERIALS AND FINISHES. CONTRACTOR TO FIELD VERIFY THE SIZE, NUMBER AND LOCATION OF THESE OPENINGS. 7. REFER TO MECHANICAL AND ELECTRICAL SHEETS FOR ADDITIONAL DEMOLITION SCOPE RELATING TO THOSE SPECIFIC TRADES. SCALE: 1/8" = 1'-0" SYLVAN LEARNING - FLOOR PLAN A9 SCALE: 1/4" = 1'-0" ENLARGED PLAN A3 SCALE: 1/8" = 1'-0" REFLECTED CEILING PLAN A6 SCALE: 1/8" = 1'-0" DEMOLITION PLAN F9 A100 New Overall Tenant Plan, & Demolition Plan CIVIL C1.01 Site Plan (Reference Only) MECHANICAL GM001 General Mechanical Information M101 First Level Mechanical and Plumbing Plans M201 Mechanical Details M301 Mechanical Schedules M401 Mechanical Specifications ELECTRICAL GE001 Electrical General Information E101 Electrical Plans and Schedules E201 Electrical Specifications INDEX OF DRAWINGS SCALE: 1/4" = 1'-0" FRAME TYPES F3 PRE-HUNG DOORS AND WOOD FRAMED WINDOWS SHEET A100 DEMOLITION NOTES DEMO 1 REMOVE PORTION OF EXISTING INTERIOR PARTITION WALL AS REQUIRED FOR NEW CONSTRUCTION. DEMO 2 REMOVE AND RELOCATE EXISTING LAVITORY AS REQUIRED FOR NEW CONSTRUCTION FOR RESTROOM 107. DEMO 3 REPLACE EXISTING GRAB BAR WITH NEW 36" LENGTH AS REQUIRED BY CODE. PROVIDE NEW BLOCKING IN WALL AS REQUIRED. WINDOWS: ASTM C 1036, TYPE 1, Q3 CLASS 1, 6.0MM CLEAR GLAZING PROVIDE FULLY TEMPERED (FT) WHERE LABELED AND/OR REQUIRED BY CODE 6-PANEL DOOR: PAINTED PER TENANT DIRECTION SCALE: 1" = 1'-0" SECTION DETAIL A1 MASONITE PRIMED MDF 15 LITE (CLEAR) FRENCH DOOR: PAINTED PER TENANT DIRECTION PROVIDE CLASSROOM LOCKING HARDWARE PROJECT SCOPE OF WORK: WITHIN EXISTING SHELL BUILDING, THE PROJECT CONSISTS OF A NEW TENANT IMPROVEMENT FOR SYLVAN LEARNING CENTER IN EXISTING VACANT TENANT SPACE. MINIMAL DEMOLITION OF EXISTING PARTITION WALLS AND FLOORING AS REQUIRED BY NEW TENANT LAYOUT. REMAINING INTERIOR FLOORS, CEILINGS, AND WALLS TO REMAIN. REUSE EXISTING ELECTRICAL, MECHANICAL, AND PLUMBING FIXTURES AS INDICATED IN DRAWINGS. ALL INTERIOR FINISHES TO BE SELECTED BY TENANT. COORDINATE INTERIOR DECISIONS WITH LEASING AGENT.

SUITE 113 55'-0 AN V - Cheever Construction Ridge Commercial Center Sylvan Learning Center - SUITE 113 ... 1" = 30'-0" J1 SHELL BUILDING KEYPLAN ... CONDUIT AND OTHER UTILITIES

  • Upload
    dohuong

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

1

A

D

8

B

C

2 3 4 5 6 7

A.2

C.8

2.2 6.8

VANVAN

VAN

VAN VAN

CE

NT

ER

LIN

E T

O F

AC

E O

F P

AN

EL

55'-0"

SUITE 113

01

B.O. CEILING

FINISHED FLOOR

NOTE 1

01B NO SOUND BATT INSULATION

4 7/8"

5/8" GWB

3" SOUND BATT

NOTE 2

A100

A32'-2"

OFFICE103

OFFICE102

WAITING100

CONFERENCE104

WOMEN105

INSTRUCTION101

MEN107

ELECTRICAL106

24

'-7 7

/8"

+/-

11'-0"

3 5

/8"

11'-0"

3 5

/8"

7'-0"

14'-0"

3 5/8" 19'-0" 3 5/8"

14'-0"

10'-0"

existing floorreceptacles toremain(8 total)

existingceramic tileentry walk-off toremain

copy/print

WD02

WD02

WD02

WD03

8"

8"

5'-0"

1'-5

"

01B

01B01

01

01

01

01

98.0

NOTE 5

FT

FT

FT

NOTE 5 NOTE 5

WD04

EXISTINGELEC.PANEL

EXISTINGDOOR

EXISTINGDOOR

WOMEN105

ELECTRICAL106

MEN107

CORRIDOR108

INSTRUCTION101

PRINTER/COPIER BYOWNER

01

01

01

01

01B

01B

01B

01

01

60"

wid

e

59"deep

4'-0"

7'-8"

4'-6"

1'-5

"

01

01B

60" wide

59"d

eep

6"1

'-0

" C

LE

AR NOTE 5

1'-8" 2'-2"

EXTGGRAB BAR

GRAB BAR 36"

NOTE 6

GRAB BAR 42"

GRAB BAR 36"

NOTE 6

3'-6"4'-0"

98.0

1'-6"

9' - 0"

10' - 4"

EXISTINGCEILING

NEW CEILING

EXTGCEILING

EXTGCEILING

NOTE 7

NOTE 8

CODE SUMMARY - 2012 IBCNon-Structural Building Code Information

General Summary:Sylvan Learning Center Tenant ImprovementBusiness Use: Training and skill development not within a school oracademic program. The existing building is designed to meet TypeII-B, Non-combustible Fully Sprinkled

Project Location:3900 Yankee Hill Road, Suite 113Lincoln, NE 68516

Construction Type: II-B UnprotectedFully Sprinkled

Occupancy Classification: Business (B)

Area of Tenant: 2,593 SF Gross Lease Area

Occupant Load: 25 OCCUPANTS max.

Exit Access 1 Exit Required (< 50 Occ.)& Egress Travel Distance: 100 ft max.

Plumbing Fixture Count: 1 Private Mens(City Plumbing Code 1 Private WomensException 24.10.140) (with 25 Max. Occupants)

DEMO 1

DEMO 1

DEMO 2

DEMO 3

6'-0"

2'-8"

4'-0"

WD02

NOTE 3

*FT

*ADJACENT TO OFFICEDOORS (NOTED IN PLAN)

6'-8"

WD01

6'-8"

NOTE 5

8'-0"

4'-0"

2'-8"

WD03

NOTE 3

EQ2 1/2"EQ

MIN

.

1'-7"

2'-0"

6" EDGE RIM

1'-6"

TO

P R

IM

FEMININE NAPKINDISPOSAL AT WOMENSTOILETS ONLY

TOILET PAPERDISPENSER

3'-6" 1'-0"

GRAB BAR

3'-0" 6"

1'-6"

2'-10"

ACCESSIBLE FIXTURES AND ACCESSORIES

MIN.

1'-0"

MIN.

1'-0"

2' -

8"

MA

X.

3' -

2"

MIN

.

MAX.1'-0"

24" MINIMUM

3'-6" PREFERRED

2'-8"

MA

X.

3'-2"

MIN

.

GRAB BAR REINFORCEMENTLOCATION AT WATER CLOSETS

1/4

"3

/4"

SILL

BASE

HEAD(JAMB SIM.)

1/4

"3

/4"

2 1/2"

102'-8"

106'-8"

4 7/8"

1 1/4"

1 1/4"

2 1

/2"

2 1

/2"

2 1

/2"

1/4

"

2 1

/2"

1/4

"

5/16" 4 1/4" 5/16"

VERTICALMULLION

PAINTED WOODSTOP & TRIM TYP.(BLOCKING REQ'D)

PAINTED WOODCASING TYP.(BLOCKING REQ'D)

PAINTED WOODBASE TYP.(BLOCKING REQ'D)

3 1

/2"

WD04

4'-0"

2'-10

" M

AX

.

2' -

5"

MIN

.

2'-3"

MIN

.

1'-5" MIN.

3'-6"

3'-4"

MA

X.

LAVATORY

SOAPDISPENSER

MIRRORPAPER TOWELDISPENSER

STANDARD AND ACCESSIBLEFIXTURES AND ACCESSORIES

ME

CH

AN

ICA

L /

ELE

CT

RIC

AL

EN

GIN

EE

RO

lsso

n A

ssocia

tes

601 P

Str

eet, S

uite 2

00

Lin

co

ln, N

E 6

8508

402.4

74.6

311

700 Q

St.

Lin

coln

, N

E 6

8508

T: 402 4

76 7

331 F

: 4

02 4

76 8

341

SHA PROJECTNO.

DE

SIG

N A

RC

HIT

EC

T:

PR

OJE

CT

AR

CH

ITE

CT

:

DR

AW

N B

Y:

ISS

UE

D:

RE

VIS

ION

S:

Copyright SINCLAIR HILLE ARCHITECTSC

PR

OJE

CT

CO

NS

ULT

AN

TS

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

Ya

nk

ee

Rid

ge

Co

mm

erc

ial C

en

ter

Sy

lva

n L

ea

rnin

g C

en

ter

- SU

ITE 1

13

Coordinating Professional

1/1

8/2

017 8

:41:2

8 A

M

N:\CURRENT PROJECTS\16075 Yankee Ridge Sylvan Learning Center TI\Drawing Files\1_Revit Model\16075_Architectural_Sylvan TI_2015.rvt

New

Overa

ll T

en

an

t P

lan

, &

Dem

oliti

on

Pla

n

16075

DE

L

A100

- LA

B

01/1

1/2

017

STANDARD HEIGHTSF1

SCALE: 1" = 30'-0"

SHELL BUILDING KEYPLANJ1

WOOD FRAME SECTION AND DETAILS

SHEET A100 SHEET SPECIFIC NOTES

NOTE 1 NEW PARTITION WALL FROM FLOOR TO UNDERSIDE OFEXISTING DROPPED CEILING GRID (BRACE AS REQUIRED)CONSTRUCTED OF 3-5/8", 20 GA. STUDS AT 16" O.C. W/SOUND BATT FIBER INSULATION AND 1-LAYER 5/8" GYPSUMBOARD EACH SIDE. INSTALL 5/8" MOISTURE RESISTANTGYPSUM BOARD AT RESTROOM SIDE OF WALL, TYPICAL.TAPE, SAND, AND PAINT WALL FROM FLOOR TO CEILING -COORDINATE FINISH PAINT COLOR(S) WITH FUTURE TENANTAND LEASING AGENT.

NOTE 2 BRACE TO STRUCTURE AS NEEDED.

NOTE 3 NEW INTERIOR WOOD WINDOW & CASING - PAINTED (SEEDETAIL A1/A100) WITH 1/4" CLEAR GLAZING. PROVIDE FULLYTEMPERED GLAZING WHERE REQUIRED BY CODE -COORDINATE FINISH PAINT COLOR WITH TENANT ANDLEASING AGENT.

NOTE 5 NEW 3'-0" x 6'-8" x 1-3/8" SOLID CORE 6-PANEL DOOR (MATCHEXISTING DOORS IN SPACE - CONFIRM SIZE, TEXTURE, ANDSTYLE). COORDINATE FINISH PAINT COLOR WITH TENANTAND LEASING AGENT.

NOTE 6 PROVIDE TOILET ACCESSORIES TYPICAL: SINGLE ROLLTOILET TISSUE DISPENSER, WALL MOUNT PAPER TOWELDISPENSER.

NOTE 7 PROVIDE NEW GYPSUM CEILING. EXTEND AND MATCHEXISTING FRAMING AND CEILING FINISH OF CURRENTGYPSUM CEILING AREAS.

NOTE 8 EXISTING PANEL CEILING TO REMAIN. RE-USE EXISTINGFIXTURES AS INDICATED IN DRAWINGS (SEE MECHANICAL &ELECTRICAL).

SCALE: 3/4" = 1'-0"

WALL TYPESD1

GENERAL NOTES

1 ALL DIMENSIONS ARE REFERENCED FROM FACE OF FRAMINGSTUD, FACE OF MASONRY, FACE OF CAST-IN-PLACE CONCRETEOR FACE OF PRECAST UNLESS NOTED OTHERWISE.

2 WHERE REMOVAL OF ITEMS LEAVES A HOLE OR DAMAGEDSURFACE THAT WILL BE EXPOSED IN FINISHED WORK, PATCHAND REPAIR DAMAGE TO MATCH ADJACENT FINISHED SURFACE.

3 COORDINATE WORK OF ALL OTHER TRADES WITH YOUR TRADEPRIOR TO STARTING ANY CONSTRUCTION.

4 FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TOCOMMENCEMENT OF ANY NEW CONSTRUCTION. NOTIFYARCHITECT IMMEDIATELY OF ANY DISCREPANCIES.

5 GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THECOORDINATION OF THE WORK OF ALL TRADES.

6 CONSULT ARCHITECT / STRUCTURAL ENGINEER FOR ANY ANDALL LOCATIONS WHERE UNFORSEEN OR UNUSUAL STRUCTURALCONDITIONS EXIST.

7 DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. VERIFYALL DIMENSIONS AND REPORT ANY DISCREPANCIES TO THEARCHITECT IMMEDIATELY.

8 PROVIDE BLOCKING IN WALLS FOR ALL BASE AND WALLCABINETS, TELEVISIONS, WALL HUNG EQUIPMENT, BATHACCESSORIES AND WALL APPLIED DOOR HARDWARE.

9 PLUMBING / ELECTRICAL TRADES SHALL COORDINATE THEIRWORK WITH FOUNDATIONS AS REQUIRED IN MECHANICAL /ELECTRICAL SPECIFICATIONS AND NOTES. PENETRATIONS /SLEEVES SHALL BE COORDINATED WITH ARCHITECT ANDSTRUCTURAL ENGINEER.

VICINITY MAP North

Yankee Hill Rd

S. 40th

Str

eet

S. 37th

St.

Grainger Pkwy

PROJECTLOCATION

GENERAL DEMOLITION NOTES

8. REPAIR OR REPLACE ANY EXISTING CONSTRUCTION AND FINISHESSCHEDULED TO REMAIN WHICH ARE DAMAGED DURING DEMOLITIONOPERATIONS. DAMAGED CONSTRUCTION AND FINISHES SCHEDULEDTO REMAIN SHALL BE REPAIRED OR REPLACED TO MATCH EXISTINGADJACENT CONSTRUCTION.

9. UNLESS NOTED OTHERWISE, WHERE EXISTING FIXTURES, ASSEMBLIESOR EQUIPMENT ARE REMOVED, REMOVE AND CAP ASSOCIATEDSERVICES IN A CONCEALED LOCATION AND AS REQUIRED FOR NEWWORK. REMOVE (OR REMOVE AND SALVAGE) ASSOCIATED CARRIERSAND MOUNTING DEVICES AS REQUIRED FOR REINSTALLATION OR NEWWORK. REFER TO AND COORDINATE WITH MECHANICAL ANDELECTRICAL.

10. SAW CUTTING OF CONCRETE BEYOND THE DIMENSIONS OF THEPLANNED OPENING IS PROHIBITED.

11. DEMOLITION DRAWINGS ONLY INDICATE PRIMARY DEMOLITION WORK.ALL ADDITIONAL INCIDENTAL DEMOLITION REQUIRED TO COMPLETEWORK IS TO BE INCLUDED AS PART OF THE OVERALL DEMOLITIONEFFORT WITH NO ADDITIONAL COSTS BEING ASSESSED TO THEOWNER.

12. REPAIR AND PREPARE ALL EXISTING SURFACES ADJACENT TODEMOLITION ITEMS AS REQUIRED TO RECEIVE NEW FINISHES.

13. THE OWNER RETAINS THE FIRST RIGHT OF SALVAGE FOR ALLASSEMBLIES AND EQUIPMENT. IF OWNER DECLINES, THECONTRACTOR SHALL REMOVE ITEMS FROM THE PREMISES ANDDISPOSE OF PROPRLY. VERIFY OWNER'S INTENT PRIOR TO REMOVALOR DEMOLITION.

14. REMOVE AND SALVAGE MOUNTED ITEMS AS REQUIRED BY THE WORK.REINSTALL UNLESS DIRECTED OTHERWISE BY OWNER.

15. COORDINATE RELOCATION AND STORAGE OF ANY EXISTINGFURNISHINGS & EQUIPMENT (SHOWN AND NOT SHOWN) WITH OWNERPRIOR TO COMMENCEMENT OF DEMOLITION ACTIVITIES

GENERAL DEMOLITION NOTES

1. THE EXISTING INFORMATION SHOWN ON THE DRAWINGS IS AS EXACTAS COULD BE SECURED INSOFAR AS BUILDING CONSTRUCTION ANDEXISTING CONDITIONS ARE CONCERNED. EXACT LOCATIONS,MEASUREMENTS, DISTANCES, LEVELS, ETC. WILL BE GOVERNED BYCONDITIONS AT THE JOB SITE. THE CONTRACTOR SHALL FIELD VERIFYALL EXISTING CONDITIONS AND DIMENSIONS WHICH AFFECT WORK TOBE PERFORMED AS PART OF THIS PROJECT PRIOR TO ANY NEWCONSTRUCTION OR MATERIAL FABRICATION.

2. REFER TO FLOOR PLANS FOR NEW CONSTRUCTION REQUIREMENTS.COORDINATE ALL DEMOLITION WORK WITH ALL NEW CONSTRUCTIONINDICATED.

3. ALL BOLD, DASHED LINES INDICATE EXISTING CONSTRUCTION TO BEREMOVED UNLESS NOTED OTHERWISE.

4. THESE PLANS INDICATE MAJOR ITEMS OF DEMOLITION IN THE PROJECTAND ARE NOT INTENDED TO INDICATE ALL DEMOLITION REQUIRED TOCOMPLETE THE WORK. ADDITIONAL DEMOLITION MAY BE REQUIREDOF THE CONTRACTOR IN ORDER TO COMPLETE NEW CONSTRUCTION.

5. CONTRACTOR IS TO PROVIDE OPENINGS IN WALLS AS REQUIRED BYANY NEW DUCTWORK, CONDUIT OR OTHER UTILITIES. REFER TOMECHANICAL AND ELECTRICAL PLANS FOR SIZE AND LOCATION OFPOTENTIAL OPENINGS NOT SPECIFICIALLY INDICATED AS PART OF THEDEMOLITION DRAWINGS.

6. CONTRACTOR SHALL FILL ALL OPENINGS IN EXISTING FLOOR SLABS,WALLS AND CEILINGS LEFT BY THE REMOVAL OF EXISTING DUCTWORK,CONDUIT AND OTHER UTILITIES. FILL HOLES SO AS TO MATCH THEEXISTING ADJACENT CONSTRUCTION MATERIALS AND FINISHES.CONTRACTOR TO FIELD VERIFY THE SIZE, NUMBER AND LOCATION OFTHESE OPENINGS.

7. REFER TO MECHANICAL AND ELECTRICAL SHEETS FOR ADDITIONALDEMOLITION SCOPE RELATING TO THOSE SPECIFIC TRADES.

SCALE: 1/8" = 1'-0"

SYLVAN LEARNING - FLOOR PLANA9SCALE: 1/4" = 1'-0"

ENLARGED PLANA3SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLANA6

SCALE: 1/8" = 1'-0"

DEMOLITION PLANF9

A100 New Overall Tenant Plan, & DemolitionPlan

CIVIL

C1.01 Site Plan (Reference Only)

MECHANICAL

GM001 General Mechanical Information

M101 First Level Mechanical and PlumbingPlans

M201 Mechanical Details

M301 Mechanical Schedules

M401 Mechanical Specifications

ELECTRICAL

GE001 Electrical General Information

E101 Electrical Plans and Schedules

E201 Electrical Specifications

INDEX OF DRAWINGS

SCALE: 1/4" = 1'-0"

FRAME TYPESF3PRE-HUNG DOORS AND WOOD FRAMED WINDOWS

SHEET A100 DEMOLITION NOTES

DEMO 1 REMOVE PORTION OF EXISTING INTERIOR PARTITION WALLAS REQUIRED FOR NEW CONSTRUCTION.

DEMO 2 REMOVE AND RELOCATE EXISTING LAVITORY AS REQUIREDFOR NEW CONSTRUCTION FOR RESTROOM 107.

DEMO 3 REPLACE EXISTING GRAB BAR WITH NEW 36" LENGTH ASREQUIRED BY CODE. PROVIDE NEW BLOCKING IN WALL ASREQUIRED.

WINDOWS:ASTM C 1036, TYPE 1, Q3 CLASS 1, 6.0MM CLEAR GLAZINGPROVIDE FULLY TEMPERED (FT) WHERE LABELED AND/ORREQUIRED BY CODE

6-PANEL DOOR:PAINTED PER TENANT DIRECTION

SCALE: 1" = 1'-0"

SECTION DETAILA1

MASONITE PRIMED MDF 15 LITE(CLEAR) FRENCH DOOR:PAINTED PER TENANT DIRECTIONPROVIDE CLASSROOM LOCKINGHARDWARE

PROJECT SCOPE OF WORK:

WITHIN EXISTING SHELL BUILDING, THE PROJECT CONSISTS OF ANEW TENANT IMPROVEMENT FOR SYLVAN LEARNING CENTER INEXISTING VACANT TENANT SPACE. MINIMAL DEMOLITION OFEXISTING PARTITION WALLS AND FLOORING AS REQUIRED BY NEWTENANT LAYOUT. REMAINING INTERIOR FLOORS, CEILINGS, ANDWALLS TO REMAIN. REUSE EXISTING ELECTRICAL, MECHANICAL, ANDPLUMBING FIXTURES AS INDICATED IN DRAWINGS. ALL INTERIORFINISHES TO BE SELECTED BY TENANT. COORDINATE INTERIORDECISIONS WITH LEASING AGENT.

dleblanc
Typewritten Text
C1.01 SITE PLAN IS FOR REFERENCE ONLY NEW WORK TO BE DONE UNDER SEPARATE PERMIT
dleblanc
Cloud

BOILER BLOW DOWN

STEAM CONDENSATE DRAIN ABOVE GRADE

STEAM CONDENSATE DRAIN BELOW GRADE

HIGH PRESSURE CONDENSATE

HIGH PRESSURE STEAM

LOW PRESSURE CONDENSATE

LOW PRESSURE STEAM

MEDIUM PRESSURE CONDENSATE

BBD

STEAM

CD

CD

HPC

HPS

LPC

LPS

MPC

MEDIUM PRESSURE STEAMMPS

STEAM TRAP

HYDRONIC

CHILLED WATER RETURN

CHILLED WATER SUPPLY

MAKE�UP WATER

HEATING WATER RETURN

HEATING WATER SUPPLY

HOT/CHILLED WATER RETURN

HOT/CHILLED WATER SUPPLY

HEAT PUMP RETURN

CHWR

CHWS

MU

HHWR

HHWS

HCWR

HCWS

HPR

HEAT PUMP SUPPLYHPS

MECHANICAL SYMBOL LEGEND

COOLING TOWER SUPPLY

COOLING TOWER RETURN

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

ENERGY RECOVERY RETURN

ENERGY RECOVERY SUPPLY

AUTOMATIC AIR VENT

MANUAL AIR VENT

CTS

CTR

CR

CS

ERR

ERS

SITE

WATER SERVICE

CURB STOP VALVE

SANITARY SEWER (SITE)

POST INDICATOR VALVE

POST INDICATOR VALVE WITH TAMPER SWITCH

BUILDING SPRINKLER FIRE MAIN

STORM SEWER (SITE)

STORM DRAIN

THRUST BLOCK

LAWN SPRINKLER

WATER MAIN

WELL

YARD HYDRANT

TREE

WIRE FENCE

GAS RISER

GAS METER

ELECTRICAL RISER

SWITCH BOX

PROPERTY CORNER

CONTROL POINT

BENCHMARK

MAIL BOXES

WOODEN POST

TIE DOWN

CONCRETE

GRAVEL

TS

W

SAN

FM

SS

SD

LS

W

W

YHT

GAR

GM

ER

SB

WDP

MLB

PRP

GENERAL SANITARY & DOMESTIC

SANITARY DRAIN BELOW GRADE (PLAN)

SANITARY DRAIN ABOVE GRADE (PLAN)

COLD WATER (CW)

HOT WATER (HW)

HOT WATER CIRCULATING (HWC)

140°F DOMESTIC HOT WATER

TEMPERED WATER

TEMPERED WATER CIRCULATING

VENT

VENT BELOW FLOOR

ACID VENT

ACID WASTE

CONDENSATE DRAIN PIPING

140 HW

T

TC

V

VBF

AV

AW

CD

ROOF DRAIN (ABOVE GRADE)RD

ROOF DRAIN (BELOW GRADE)RD

OVERFLOW DRAIN (ABOVE GRADE)OD

OVERFLOW DRAIN (BELOW GRADE)OD

SOFT COLD WATERSCW

SOFT HOT WATERSHW

SUB�SOIL DRAINSS

FORCE MAIN (PUMP DISCHARGE)FM

FIRE

FIRE PROTECTION PIPING

FIRE DEPARTMENT CONNECTION

DUCT SMOKE DETECTOR AND RELAY

F

DUCT

SD

TS

FS

TAMPER SWITCH

FLOW SWITCH

SPRINKLER HEAD, PENDANT

SPRINKLER HEAD, SIDE WALL

ALARM VALVE, WET

ALARM VALVE, DRY

FIRE PROTECTION RISER

FIXTURES

WATER CLOSET AND TYPE

URINAL AND TYPE

LAVATORY OR SINK AND TYPE

BATHTUB AND TYPE

SHOWER AND TYPE

SERVICE SINK OR MOP SINK AND TYPE

ELECTRIC WATER COOLER AND TYPE

VENT THRU ROOF

ROOF DRAIN

OVERFLOW DRAIN

GRADE CLEAN OUT

VTR

RD�1

OD�1

GCO

FCO

WCO

CO

HB�1

WH�1

YH�1

FLOOR CLEAN OUT

WALL CLEAN OUT

HORIZ. CLEAN OUT

FLOOR DRAIN OR SINK AND TYPE

HOSE BIBB

WALL HYDRANT

DOWNSPOUT NOZZLE

FD�1/FS�1

YARD HYDRANT

HVAC

X�112x8300

T

H

CEILING DIFFUSER

LINEAR DIFFUSER

SUPPLY REGISTER

RETURN AIR GRILLE

RETURN AIR GRILLE

EXHAUST AIR GRILLE

THERMOSTAT

HUMIDISTAT

DESIGNATIONNECK SIZECFM

DESIGNATIONDIFFUSER LENGTHCFM

DESIGNATIONSIZECFM

DESIGNATIONSIZECFM (OPTIONAL)

DESIGNATIONSIZECFM (OPTIONAL)

DESIGNATIONSIZECFM

CO2 CARBON DIOXIDE SENSOR

HCG

12x8

12"ø

12/8

RECTANGULAR DUCT (WxH)

ROUND DUCT (DIA.)

OVAL DUCT (W/H)

FLEXIBLE DUCT

SUPPLY AIR/OUTSIDE AIR UP AND DOWN

RETURN AIR UP AND DOWN

EXHAUST AIR UP AND DOWN

MANUAL VOLUME DAMPER

MOTORIZED DAMPER

BACKDRAFT DAMPER

FIRE DAMPER

SMOKE DAMPER

COMBINATION FIRE AND SMOKE DAMPER

TURNING VANES

HARDWARE CLOTH GRILLE

VOLUME EXTRACTOR

SPECIALTY SYSTEMS

REVERSE OSMOSISRO

OXYGEN PIPING

REFRIGERANT DISCHARGE

FUEL OIL RETURN

FUEL OIL SUCTION

FUEL OIL VENT

NATURAL GAS

LIQUID PETROLEUM GAS

COMPRESSED AIR

LIQUID REFRIGERANT

SUCTION REFRIGERANT

PAIR REFRIGERANT LINES (SUCTION, LIQUID)

PROPANE

FOV

G

LPG

A

LR

SR

RL

P

CARBON DIOXIDECO2

NITROGENN

AIR OUTLETA

VACUUM (AIR)VAC

DISTILLED WATERDI

LABORATORY VACUUMLV

MEDICAL VACUUMMV

NITROUS OXIDEN2O

OX

RD

FOR

FOS

LIQUID OXYGENLOX

LABORATORY COMPRESSED AIRLA

MEDICAL COMPRESSED AIRMA

DEIONIZED WATERDE

CD�18"ø200

LD�14'�0"300

R�110x8250

RA�112x12250

G�112x8250

NEW TO EXISTING

SHEET KEYNOTE

REVISION DELTA

PIPE UP OR DUCT UP

PIPE OR DUCT DOWN

#

#

PIPE OR DUCT CAP

PIPE ANCHOR

PIPE GUIDE

PIPE ROLLER SUPPORT

FLOW DIRECTION ARROW

PIPE EXPANSION JOINT

FLEXIBLE CONNECTOR

CONCENTRIC REDUCER

ECCENTRIC REDUCER

VALVES

T&P RELIEF VALVE

ISOLATION VALVE

ISOLATION VALVE IN VERTICAL POSITION

CHECK VALVE

BALANCING VALVE

AUTOMATIC 2�WAY VALVE

AUTOMATIC 3�WAY VALVE

PRESSURE REDUCING & REGULATING VALVE

PRESSURE REGULATING VALVE

DIAPHRAGM VALVE

ANGLE VALVE

STRAINER

UNION

DOUBLE LINE PIPE LEGEND

BUTTERFLY VALVE

GATE VALVE

TEMPERATURE CONTROL VALVE

GATE VALVE

CHECK VALVE

BASKET STRAINER

NOTE: DOUBLE LINE PIPE IDENTIFIED BY SYSTEM ABBREVIATION

DEMOLITION

EXISTING

NEW

R

ME

CH

AN

ICA

L /

ELE

CT

RIC

AL

EN

GIN

EE

RO

lsson

Asso

cia

tes

60

1 P

Str

ee

t, S

uite

20

0L

inco

ln, N

E 6

850

84

02.4

74

.631

1

70

0 Q

St.

Lin

co

ln,

NE

68

50

8T

: 4

02

47

6 7

33

1 F

: 4

02

47

6 8

34

1

SHA PROJECTNO.

DE

SIG

N E

NG

INE

ER

:

PR

OJE

CT

EN

GIN

EE

R:

DR

AW

N B

Y:

ISS

UE

D:

RE

VIS

ION

S:

Copyright SINCLAIR HILLE ARCHITECTSC

PR

OJE

CT

CO

NS

ULT

AN

TS

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

13 14

A

B

C

D

E

F

G

H

J

K

L

M

13 14

Ya

nk

ee

Rid

ge

Co

mm

erc

ial C

en

ter

Sy

lva

n L

ea

rnin

g C

en

ter

OA

PR

OJE

CT

#:

01

6�3

52

1

D:\Revit locals and backups\2015\ME_Sylvan TI_Central_63521_chayes.rvt

1/1

7/2

01

7 1

1:0

8:2

5 A

M

Gen

era

l M

ech

an

ical In

form

ati

on

16073

GM001

12

/28

/20

16

Au

tho

r

De

sig

ner

Ap

pro

ve

r

SHEET LISTSHEET

NUMBER SHEET NAME

GM001 General Mechanical Information

M101 First Level Mechanical and Plumbing Plans

M201 Mechanical Details

M301 Mechanical Schedules

M401 Mechanical Specifications

M101

A9

3/4"

3/4

"

3/4"

3/4"

4"

4"

4"

7

8

EWH�1

FD�1

L�1

WC�1

EWC�1

FCO

100

CD�16"ø

100

CD�16"ø

RA�110x22

RA�110x22

RA�122x22

EF�1

RA�122x22

NOTE: MAXIMUM TOTAL CFM IN DUCT BY SIZE: 10x10 (OR EQUIVALENT) 500 CFM 20x10 (OR EQUIVALENT) 1000 CFM 20x16 (OR EQUIVALENT) 2000 CFM 20x20 (OR EQUIVALENT) 3000 CFM

EUH�1

6"ø EA

9 10

11

11

11

11

11

11

11

12

5

5

5

5

325 CFM

325 CFM340 CFM

325 CFM

325 CFM

325 CFM

300 CFM

80 CFM

80 CFM

5

30 CFM

11

30 CFM

11

3/4

"3

/4"

3/4"

1/2"

3/4"

1/2

"

3/4"

2"

V

1 1/2" V

2"

V

4"

4"

4"

4"

2" V

2" VBF

2" VBF

7

8

FD�1

L�1

WC�1

EHW�1

FCO

EWC�1

1

2

3

4

EXISTING ROOFTOP UNIT

5 5

6

4

4

4

4

4

4

4

5

5

4

3

ME

CH

AN

ICA

L /

ELE

CT

RIC

AL

EN

GIN

EE

RO

lsson

Asso

cia

tes

60

1 P

Str

ee

t, S

uite

20

0L

inco

ln, N

E 6

850

84

02.4

74

.631

1

70

0 Q

St.

Lin

co

ln,

NE

68

50

8T

: 4

02

47

6 7

33

1 F

: 4

02

47

6 8

34

1

SHA PROJECTNO.

DE

SIG

N E

NG

INE

ER

:

PR

OJE

CT

EN

GIN

EE

R:

DR

AW

N B

Y:

ISS

UE

D:

RE

VIS

ION

S:

Copyright SINCLAIR HILLE ARCHITECTSC

PR

OJE

CT

CO

NS

ULT

AN

TS

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

Ya

nk

ee

Rid

ge

Co

mm

erc

ial C

en

ter

Sy

lva

n L

ea

rnin

g C

en

ter

OA

PR

OJE

CT

#:

01

6�3

52

1

D:\Revit locals and backups\2015\ME_Sylvan TI_Central_63521_chayes.rvt

1/1

7/2

01

7 1

1:0

8:2

7 A

M

Fir

st

Level M

ech

an

ical an

d P

lum

bin

gP

lan

s

16073

M101

12

/28

/20

16

Au

tho

r

De

sig

ner

Ap

pro

ve

r

SCALE: 1/8" = 1'�0"

FIRST LEVEL PLUMBING PLANG5SCALE: 1/8" = 1'�0"

FIRST LEVEL HVAC PLANG9

SCALE: 1/4" = 1'�0"

ENLARGED PLAN � PLUMBINGA9

SCALE: 1/8" = 1'�0"

FIRST LEVEL MECHANICAL DEMOLITION PLANG1

SHEET KEYNOTES1 REMOVE AND REUSE EXISTING FIXTURE AND

INSTANTANEOUS ELECTRIC WATER HEATER. REMOVE ALLWATER PIPING AND SANITARY/VENT PIPING TO BELOWFLOOR OR TO MAIN ALONG CEILING AND CAP. DO NOTLEAVE DEAD LEGS OF WATER PIPING.

2 REMOVE EXISTING CW TAP FOR SPACE BACK TO MAINAND CAP.

3 EXISTING BATHROOM EXHAUST SYSTEM AND SUPPLYDUCTWORK TO REMAIN.

4 REMOVE AND REUSE EXISTING AIR DEVICE. REMOVEASSOCIATED BRANCH DUCT BACK TO MAIN. PATCH ANDSEAL REMAINING HOLE IN DUCTWORK.

5 EXISTING AIR TERMINAL DEVICE TO REMAIN. EXISTINGDUCTWORK TO REMAIN WHERE SIZING MEETS CRITERIANOTED ON VIEW G9/M101.

6 THERMOSTAT TO BE REMOVED AND RELOCATED. SEEVIEW G9/M101 FOR NEW LOCATION.

7 CONNECT DOMESTIC COLD WATER TO RELOCATEDRESTROOM LAVATORY AND INSTANTANEOUS ELECTRICWATER HEATER.

8 CONNECT TO EXISTING 4" VTR.

9 VERIFY LOCATION OF EXISTING AIR HANDLING UNIT ANDDUCT MAINS.

10 SET ROOFTOP UNIT TO 400 CFM MINIMUM OUTSIDE AIRINTAKE. SET ROOFTOP UNIT SUPPLY AIR FAN TO 2,625CFM.

11 RELOCATED AIR TERMINAL.

12 LOCATE EXHAUST OUTLET 10'�0" MIN FROM OUTDOOR AIRINTAKES.

GENERAL SHEET NOTESA.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

THE CONTRACTOR SHALL PROTECT, AS REQUIRED, ALLMATERIALS AND FINISHES SCHEDULED TO REMAIN. IFMATERIALS OR FINISHES SCHEDULED TO REMAIN AREDAMAGED, THEY SHALL BE REPAIRED OR REPLACED TOMATCH EXISTING AT NO ADDITIONAL COST TO THE OWNER.

SUPPORT EXISTING ELECTRICAL, DATA, PHONE, AND TVWIRING WHERE REQUIRED WHEN PIPING, DUCTWORK,CEILING, ETC. ARE REMOVED. PROTECT WIRING FROMBEING DAMAGED DURING DEMO AND CONSTRUCTION. ANYDAMAGED CABLING, WIRING, OR RACEWAY SHALL BEREPLACED IN ITS ENTIRETY.

ALL EXISTING PIPING, DUCTWORK, EQUIPMENT ANDACCESSORIES ARE NOT NECESSARILY SHOWN ON THISDRAWING. EXISTING SYSTEMS SHOWN ARE AS DEEMEDNECESSARY TO PROVIDE INTENT OF DEMOLITION WORKINVOLVED IN THIS PROJECT. CONTRACTOR SHALL FIELDVERIFY ITEMS PRIOR TO BID.

ALL DASHED PIPING, DUCTWORK, EQUIPMENT, ETC. ISDESIGNATED FOR REMOVAL UNLESS SPECIFICALLY NOTEDOTHERWISE. ALL PIPING TO BE CAPPED OR PLUGGEDBEHIND WALLS AND BELOW FLOORS.

COORDINATE ITEMS TO BE SALVAGED WITH OWNER.

KEEP NOISE LEVEL TO A MINIMUM DURING NORMALBUILDING WORKING HOURS.

GENERAL CONTRACTOR SHALL PATCH ALL HOLES LEFTFROM REMOVING PIPES, DUCT, EQUIPMENT, ANDCONTROLS. COORDINATE FINISH REQUIREMENTS WITHARCHITECT.

MODIFY FIRE SPRINKLER HEAD AND PIPING LAYOUT TO SUITNEW FLOOR PLAN LAYOUT. FIELD VERIFY EXACT HEADLOCATIONS AND PIPE SIZES.

SEE ARCHITECTURAL PLANS FOR PHASING ANDCONSTRUCTION BOUNDARIES.

COORDINATE THE SCHEDULING, AND SHUT�DOWN,ISOLATION, DRAINING AND VENTING OF EXISTING SYSTEMSWITH OWNER. FOLLOW SITE PROCEDURES FOR LOCK OUT /TAG OUT REQUIREMENTS.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALLSCAFFOLDING, OR MAN�LIFTS WHERE FEASIBLE, TO ALLOWFOR THE SAFE ACCESS AND DEMOLITION OF ALLDUCTWORK AND PIPING SHOWN TO BE REMOVED.

REMOVE ALL SANITARY AND VENT PIPING TO BELOW FLOORSLAB AND CAP TO BE CONCEALED UNDER NEW PATCHEDCONCRETE SLAB.

ALL SUPPLY DEVICES SHALL BE INSTALLED WITH MANUALBALANCING DAMPERS. DAMPERS SHALL BE INSTALLED INACCESSIBLE LOCATIONS.

EXISTING RETURN AIR PLENUM SHALL REMAIN. RELOCATEDAND NEW RETURN AIR DEVICES SHALL BE OPEN TOPLENUM.

CEILING

LAY-IN FRAME. REFER

TO DRAWINGS AND

SCHEDULES FOR

REQUIREMENTS.

INSULATED FLEXIBLE

DUCT WITH BAND

FASTENER

NOTE:

1. REFER TO PLANS FOR DUCT SIZES.

2. FLEX DUCT MAY BE ALTERNATIVELY POSITIONED BEFORE THE RIGID ELBOW.

MINIMUM 4"

COLLAR

RIGID ELBOW

ECCENTRIC REDUCING FITTING

W xD

W xD

CONCENTRIC REDUCING FITTING

SQUARE THROAT 90° ELBOW

W xD

1

90°

2

22

W xD

STANDARD RADIUS ELBOW

R

W

VANE

SHORT RADIUS ELBOW WITH TWO VANES

SHORT RADIUS ELBOW WITH ONE VANE

DUCT DIMENSION

= DOWNSTREAM

DUCT DIMENSION

1

= UPSTREAM

1

2

/

W

W

VANE

1

2

/

3

W

R

3

W

2

/

1

1

W

/

3

W

R

1

W

/

6

qq

q =60° MAX CONVERGING

TWO-SIDE

REDUCTION

q = 30° MAX

STANDARD SINGLE VANES,

ADJUSTABLE FOR ELBOWS OR

UNIVERSAL AND OUTLET

DIMENSIONS

q

R SHALL EQUAL

OR BE GREATER

THAN W

OR BE GREATER

R SHALL EQUAL

THAN W/

1

6

q =45° MAX DIVERGING

OR BE GREATER

R SHALL EQUAL

THAN W/

1

3

1

W =D

2 2

W =D

1 1

ONE-SIDE

REDUCTION

W xD

2 2

W xD

1 1

45 DEGREE ENTRY = 45°

CLOSE OPENING AT CORNERS

L = 1/4 W, 4" MIN.

L

W

q

CEILING

BIRDSCREEN

ROOF CAP

SECURE TO ROOF AND CAULK

WATERTIGHT ALL AROUND

SEE ARCH. DWG. FOR

ROOF CONSTRUCTION

CEILING

FAN

4" DUCT TO

ROOF CAP

UNISTRUT CHANNEL

PIPE

INSULATION

HANGER ROD

INSULATION

PIPE

PROVIDE A SECTION OF

HIGH COMPRESSION

STRENGTH INSULATION AT

EACH HANGER POINT.

INSULATION MAY BE HALF

ROUND OR FULL ROUND &

EXTENDED 2" BEYOND

GALV. SHIELD EA. WAY.

GALV. IRON

SHEET SHIELD

(12" LONG)

NOTES:

1. ATTACH SUPPORTS FOR ALL PIPING SUSPENDED FROM THE STEEL

STRUCTURE TO THE TOP CORD OF JOISTS OR BEAMS.

2. PROVIDE COPPER OR PLASTIC COATED HANGERS FOR

NON-INSULATED COPPER PIPE.

EWH-1

3/8" COPPER TUBING

CW

HW

CW

JUNCTION BOX WITH

DISCONNECT SWITCH

1/2" THREE-WAY

ANGLE STOP VALVE

EXTERIOR CLEANOUT INTERIOR CLEANOUT

"CO" TO BE CAST IN COVER

CAST IRON LONG SWEEP

1/4 BEND OR CAST IRON

COMB, "Y" & 1/8 BEND. (USE

REDUCING TYPE WHEN

REQUIRED)

CAST IRON

EXTENSION, SAME

SIZE AS SEWER UP

TO 4" DIA.

BUILDING DRAIN OR

SEWER MATERIAL AND

SIZE AS SPECIFIED

DIRECTION

OF FLOW

FINISHED

FLOOR

CAST IRON CLEANOUT

WITH COVER FOR DUTY

REQUIRED

6" THICK BY 18"

SQUARE

CONCRETE PAD

GRADE OR

PAVING

EXTERIOR CLEANOUT

"CO" TO BE CAST IN COVER

CAST IRON LONG SWEEP

1/4 BEND OR CAST IRON

COMB, "Y" & 1/8 BEND. (USE

REDUCING TYPE WHEN

REQUIRED)

BUILDING DRAIN OR

SEWER MATERIAL AND

SIZE AS SPECIFIED

CAST IRON

CLEANOUT WITH

COVER FOR DUTY

REQUIRED

26"x18" BY

6" THICK

CONCRETE

PAD

GRADE OR

PAVING

SEE

PLANS

DOUBLE

H1

NOT TO SCALE

SHEET METAL FITTINGS DETAIL H5

NOT TO SCALE

TAKE-OFF FITTING DETAIL H8

NOT TO SCALE

DIFFUSER CONNECTION DETAIL H11

NOT TO SCALE

TOILET EXHAUST DETAIL

D1

NOT TO SCALE

TYPICAL CLEANOUTS D7

NOT TO SCALE

PIPE INSULATION DETAIL D11

NOT TO SCALE

ELECTRIC WATER HEATER CONNECTIONS

BACKDRAFT DAMPER

ROOF CURB

ME

CH

AN

IC

AL

/

EL

EC

TR

IC

AL

E

NG

IN

EE

R

Olsso

n A

sso

cia

te

s

21

11

S

ou

th

6

7th

S

tre

et

Su

ite

2

00

Om

ah

a, N

E 6

81

06

40

2.3

41

.1

11

6

700 Q

S

t.

Lincoln, N

E 68508

T: 402 476 7331 F

: 402 476 8341

SHA PROJECT

NO.

DE

SIG

N E

NG

IN

EE

R:

PR

OJE

CT

E

NG

IN

EE

R:

DR

AW

N B

Y:

IS

SU

ED

:

RE

VIS

IO

NS

:

Copyright SINCLAIR HILLE ARCHITECTSC

PR

OJE

CT

C

ON

SU

LT

AN

TS

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

1/17/2017 11:07 A

M

F:\2016\3501-4000\016-3521\40-design\AutoCAD\final plans\Sheets\MECH\Mechanical\M_DTL_63521.dwg

16073

01/11/2017

Sylv

an L

earn

ing

Cen

ter

Yank

ee R

idge

Com

mer

cial

Cen

ter

OA

P

RO

JE

CT

#:

016-3521

13 14

Mech

an

ical D

etails

M201

BR

M

TJR

SR

R

EXHAUST FANS

MARK SERVES CFM

REMARKS:

1. ON/OFF CONTROL VIA OCCUPANCY SENSOR INTEGRAL TO LIGHTING CONTROL, BY

ELECTRICAL CONTRACTOR.

2. PROVIDE WITH 14" ROOF CURB FOR DISCHARGE CAP.

3. PROVIDE WITH DISCONNECT.

4. PROVIDE WITH GRAVITY BACKDRAFT DAMPER AT ROOF LINE.

5. PROVIDE WITH GREENHECK RCC-7 CURB CAP OR EQUAL WITH BIRDSCREEN.

6. PROVIDE WITH DESIGNER GRILLE.

7. PROVIDE WITH INTEGRAL BACKDRAFT DAMPER IN OUTLET DUCT COLLAR.

8. ALTERNATE MANUFACTURERS: CARNES, LOREN COOK, PENN BARRY, BROAN, OR

APPROVED EQUAL.

EF-1 BATHROOM 70 1.3 GREENHECK SP-B90

MANUFACTURER

& MODEL

FRPM

700

ESP

0.25

WATTS

20

MAX

SONES

REMARKS

1,2,3,4,5,6,7,8NOTE 1

OPERATED

BY

VOLT PH HZ

ELECTRICAL DATA

115 1 60

UNIT HEATERS (ELECTRIC)

CFM KW MBH EAT (°F) LAT (°F)

ELECTRIC COIL DATA

VOLT PH HZ AMPS

ELECTRICAL DATA

MOUNTING

175 3.0 10.2 65 137 208 1 60 14.4

REMARKS

MANUFACTURER

& MODEL

MARKEL 3380 1,2,3,4,5

REMARKS:

1. PROVIDE WITH UNIT MOUNTED, TAMPER PROOF THERMOSTAT.

2. PROVIDE WITH DISCONNECT SWITCH.

3. PROVIDE MOUNTING KIT FOR LAY-IN CEILING.

4. ALTERNATE MANUFACTURERS: QMARK, INDEECO, RAYWALL AND APPROVED EQUAL.

5. UNIT SHALL BE SET TO INITIATE WHEN ROOM TEMPERATURE DROPS BELOW 65

DEGREES.

MARK

EUH-1

LOCATION

WAITING CEILING

EXISTING ROOFTOP UNITS

REMARKS

MANUFACTURER

& MODEL

CARRIER 48TCED08 (EXISTING) 1,2

REMARKS:

1. ECONOMIZER WITH BAROMETRIC RELIEF.

2. EXISTING UNIT TO REMAIN.

MARK

AHU-1

LOCATION

OVER RR CORRIDOR 2625

CFM

400

OA CFM

11

EER

1.0

ESP

IN H20

7.5

TONS

63 83

COOLING CAP (MBTUH)

SENSIBLE TOTAL

180 148

HEATING CAP (MBTUH)

INPUT OUTPUT

ELECTRICAL

V PH MCA

208 3 39

DOMESTIC WATER HEATERS (ELECTRIC)

MARK REMARKS

1,2,3EWH-1 0 1.0 49 110 208/1 7.2 STIEBEL ELTRON DHC 10-2

LOCATION

RESTROOM

ELECTRICAL

VOLT/PH

INPUT

(KW)

REMARKS:

1. REPLACEABLE FILTER IN INLET CONNECTOR.

2. HIGH TEMPERATURE LIMIT SWITCH WITH AUTOMATIC RESET.

3. ALTERNATE MANUFACTURERS: EEMAX, RHEEM, OR APPROVED EQUALS.

STORAGE

(GAL.)

RECOVERY

(GPH)

TEMP RISE

(°F)

TEMP SETTING

(°F)

MANUFACTURER

& MODEL

TAG TYPE MANUFACTURER MODEL DESCRIPTION ACCESSORIES

CONNECTIONS

WASTE VENT CW HW

REMARKS:

1. VERIFY ALL CONNECTIONS & MOUNTING HEIGHTS WITH CODES, MANUFACTURERS, AND PLANS.

2. SIZES LISTED INDICATE MIN. SIZE ONLY, SEE PLUMBING RISERS AND FLOOR PLANS FOR LARGER SIZES.

3. ALTERNATE MANUFACTURERS MAY BE USED IF EQUAL TO TYPE SPECIFIED.

PLUMBING FIXTURE SCHEDULE

3

1,2

3

FLOOR CLEANOUT

-FCO

CLEANOUT SHALL BE THE SAME SIZE AS PIPING UP TO 4". 4" AND LARGER PIPING

SHALL BE A 4" CLEANOUT.

CAST IRON BODY, WITH GAS AND WATER-TIGHT

ABS TAPERED THREAD PLUG AND ROUND

POLISHED BRONZE SCORIATED SECURED TOP,

ADJUSTABLE TO FINISH FLOOR.

- --

Z1400ZURN

ROUND FLOOR DRAIN

-FD-1

DIMENSIONS OF TOP STRAINER: 2" OUTLET WITH A 5" STRAINER, 3" OR 4" OUTLET

WITH 8" STRAINER, 6" OUTLET WITH A 10" STRAINER.

PROVIDE TY SEALS FOR FLOOR DRAINS MOUNTED IN FLOORS ABOVE GRADE.

VERIFY PIPE SIZES ON PLANS.

CAST IRON TWO PIECE BODY WITH DOUBLE

DRAINAGE FLANGE, WEEP HOLES, REVERSIBLE

CLAMPING COLLAR, NICKEL BRONZE ADJUSTABLE

STRAINER.

2" -

Z415BZURN 2"

ELECTRIC WATER

COOLER, TWO STATION

ADA

-EWC-1

PROVIDE CHROME-PLATED COPPER SUPPLY STOPS, CHROME-PLATED

CAST-BRASS TRAP WITH CLEANOUT (0.045" THICK TUBULAR BRASS WASTE TO

WALL) AND WALL ESCUTCHEONS.

TWO STATION WALL MOUNT WATER COOLER. 8 GPH

AT 90°F AMBIENT, 370 WATTS, 4.0 FLA, 115V/60 HZ,

SELF-CLOSING EASY-TOUCH CONTROLS ON THE

FRONT, LEFT AND RIGHT OF EACH UNIT, AND

FLEXI-GUARD SAFETY BUBBLER. ADA COMPLIANT

LOW STATION.

1/2"

EZSTL8CELKAY

1-1/2"

(2"

BELOW

SLAB)

1-1/4"

(2"

BELOW

SLAB)

L-1

LAVATORY

WALL HUNG

ADA

PROVIDE WITH FLOOR-MOUNTED FIXTURE CARRIER, CHROME-PLATED COPPER

SUPPLIES WITH LOOSE TEE KEY STOPS. PROVIDE 1-1/2" CHROME-PLATED

CAST-BRASS TRAP WITH CLEANOUT AND WALL ESCUTCHEONS.

KOHLER "CORALAIS" K-15182 FAUCET, ADA-COMPLIANT, CHROME-PLATED METAL

CONSTRUCTION, ONE-PIECE LEVER HANDLE FAUCET, 1.0 GPM VANDAL

RESISTANT AERATOR, HIGH-TEMP LIMIT STOP, AND CHROME PLATED BRASS GRID

STRAINER. WITH COVERED EXPOSED HOT/COLD SUPPLIES AND WASTE PIPING

USING TRUEBRO 'LAV GUARD' INSULATED VINYL PIPE COVERS WITH

ANTI-MICROBIAL, REUSABLE FASTENERS AND STOP VALVE LOCKING ACCESS

COVER.

1-1/2"

WHITE, VITREOUS CHINA, FRONT OVERFLOW,

D-SHAPED BOWL, FAUCET LEDGE AND

SELF-DRAINING DECK AREA WITH CONTOURED

BACK AND SIDE SPLASH SHIELDS. FAUCET HOLES

SHALL BE 4" ON CENTER. MOUNTED AT ADA

HEIGHT.

1/2" 1/2"

"KINGSTON"

K-2005

KOHLER

1-1/4"

WC-5

WATER CLOSET

FLOOR MOUNTED

FLUSH TANK

INCLUDE BOLT CAPS MATCHING FIXTURE, CHROME PLATED SUPPLY WITH STOP

VALVE AND ESCUTCHEON, AND KOHLER "LUSTRA" K-4650, ELONGATED SEAT,

OPEN FRONT, WITH LID.

3"

ELONGATED, VITREOUS CHINA BOWL WITH CLASS 5

FLUSHING DESIGN, FLOOR MOUNTED, 1.6 GPF.

1/2" -

"WELLWORTH"

K-3978

KOHLER

2"

AIR DISTRIBUTION DEVICES

MARK SERVES COLOR DAMPER PATTERN MAX NC REMARKS

REMARKS:

1. VERIFY BORDER TYPE REQUIRED.

2. NECK SIZE INDICATED ON PLANS.

3. STEEL CONSTRUCTION.

4. NOT USED

5. FRONT BLADES PARALLEL WITH SHORT DIMENSION.

6. PERFORATED FACE TO BE FLUSH WITH CEILING.

7. 3/4" BLADE SPACING.

8. FLAT BLACK PAINT SHALL BE PROVIDED BEHIND DEVICES THAT SHOW

DUCTWORK.

9. ALTERNATE MANUFACTURERS: PRICE INDUSTRIES, METALAIRE, TUTTLE & BAILEY,

CARNES, NAILOR, US AIRE, OR APPROVED EQUAL.

10. MATCH FINISH WITH EXISTING AIR DEVICES.

CD-1 SUPPLY WHITE 360° 30 0.1 TITUS OMNI (24x24 FACE) 1,2,3,9,10

MANUFACTURER

& MODEL

MAX PD

IN WC

OBD

R-1 SUPPLY WHITE DOUBLE DEFL. 30 0.1 TITUS 300 RS 1,2,3,5,7,8,9,10OBD

RA-1 RETURN WHITE PERFORATED 30 0.1 TITUS PAR (12x24 OR 24x24 FACE) 1,2,3,6,8,9,10-

ME

CH

AN

IC

AL

/

EL

EC

TR

IC

AL

E

NG

IN

EE

R

Olsso

n A

sso

cia

te

s

21

11

S

ou

th

6

7th

S

tre

et

Su

ite

2

00

Om

ah

a, N

E 6

81

06

40

2.3

41

.1

11

6

700 Q

S

t.

Lincoln, N

E 68508

T: 402 476 7331 F

: 402 476 8341

SHA PROJECT

NO.

DE

SIG

N E

NG

IN

EE

R:

PR

OJE

CT

E

NG

IN

EE

R:

DR

AW

N B

Y:

IS

SU

ED

:

RE

VIS

IO

NS

:

Copyright SINCLAIR HILLE ARCHITECTSC

PR

OJE

CT

C

ON

SU

LT

AN

TS

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

1/17/2017 11:07 A

M

F:\2016\3501-4000\016-3521\40-design\AutoCAD\final plans\Sheets\MECH\Mechanical\M_SCH_63521.dwg

16073

01/11/2017

Sylv

an L

earn

ing

Cen

ter

Yank

ee R

idge

Com

mer

cial

Cen

ter

OA

P

RO

JE

CT

#:

016-3521

13 14

Mech

an

ical S

ch

ed

ules

M301

BR

M

TJR

SR

R

AutoCAD SHX Text
PF

DIVISION 21/22/23 - MECHANICAL SPECIFICATIONS

SECTION 210000/220000/230000 - GENERAL PROVISIONS

THE DRAWINGS, GENERAL NOTES, THE GENERAL CONDITIONS AND DIVISION ONE GENERAL REQUIREMENTS

SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. ALL WORK SHALL COMPLY WITH LOCAL AND STATE

CODE REQUIREMENTS, INCLUDING NFPA, OSHA AND ETC. FURNISH AND OBTAIN ALL PERMITS.

ALL MATERIALS AND EQUIPMENT SHALL BE NEW, INSTALLED IN FULL COMPLIANCE WITH MANUFACTURER'S

RECOMMENDATIONS, INSTALLED IN ACCORDANCE WITH ACCEPTED GOOD PRACTICE OF THE INDUSTRY AND

ALL APPLICABLE ITEMS SHALL CARRY A U.L. LABEL.

THE WORD “PROVIDE” AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE INCLUDING ALL ITEMS

NECESSARY FOR A FULLY FUNCTIONAL SYSTEM.

FAMILIARIZE ONESELF WITH ALL REQUIREMENTS AS TO PERMITS, LICENSES, FEES, CODES AND ORDINANCES

AND ARRANGE TO COMPLY WITH THEM. ALL PERMITS, LICENSES, FEES AND INSPECTIONS REQUIRED FOR THE

WORK UNDER THIS CONTRACT SHALL BE OBTAINED AND PAID FOR UNLESS OTHERWISE SPECIFIED.

EXAMINE SITE BEFORE BIDDING. ADVISE ENGINEER PRIOR TO BID IF SITE CONDITIONS DICTATE MODIFICATION

TO THE BASE DESIGN.

COORDINATE ALL WORK WITH OTHER TRADES AND VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD.

CUT AND PATCH ONLY AS REQUIRED. COORDINATE ALL CHANGES TO BUILDING STRUCTURE WITH OWNER

AND THEIR REQUIREMENTS PRIOR TO EXECUTION.

ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE NFPA, NEC, ANSI, UL, SMACNA AND ASHRAE CODES

AND STANDARDS UNLESS SUPERCEDED BY STATE AND LOCAL REGULATION. CONFORM TO DOCUMENTS

WHEN CODES ARE EXCEEDED.

SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO OWNER'S REPRESENTATIVE FOR

FORWARDING TO ARCHITECT/ENGINEER FOR APPROVAL. SUBMITTALS SHALL BE IN ACCORDANCE WITH

GENERAL CONDITIONS AND SHALL BEAR A STAMP OF THE MECHANICAL CONTRACTOR SHOWING THAT HE

REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTORS'S APPROVAL WILL BE CAUSE FOR

REJECTION WITHOUT REVIEW BY THE ARCHITECT/ENGINEER.

SUBSTITUTION OF EQUIPMENT MAY BE PERMITTED WITH PRIOR APPROVAL OF ARCHITECT/ENGINEER

THROUGH OWNER'S REPRESENTATIVE. THE ARCHITECT/ENGINEER SHALL BE THE SOLE AND FINAL JUDGE AS

TO THE SUITABILITY OF ITEMS SUBSTITUTED FOR THOSE SPECIFIED. THE ENTIRE COST OF ALL CHANGES DO

TO SUBSTITUTION SHALL BE BORNE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.

PAINTING, IF REQUIRED, SHALL BE COORDINATED WITH AND COMPLETED BY THE GENERAL CONTRACTOR.

PROVIDE ACCESS DOORS FOR ALL DEVICES REQUIRING INSPECTION OR MAINTENANCE. MINIMUM SIZE SHALL

BE 12" x 12".

MECHANICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS JOB PROGRESSES, AND

UPON COMPLETION SHALL TURNOVER TO THE ARCHITECT/ENGINEER A “RECORD” SET OF PRINTS SHOWING

THESE CHANGES.

THE CONTRACTOR SHALL GUARANTEE THAT ALL MECHANICAL SYSTEMS SHALL BE FREE FROM DEFECTS IN

WORKMANSHIP, MATERIALS AND PERFORMANCE TO SPECIFIED CAPACITIES AND THAT IF SUCH DEFECTS

SHALL APPEAR DURING A PERIOD OF ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE, THEY WILL REMEDY

SUCH DEFECTS TO THE SATISFACTION OF THE ARCHITECT-ENGINEER AT NO EXTRA COST TO THE OWNER

WITHIN A REASONABLE TIME.

FURNISH THREE (3) COPIES OF THE OPERATING AND MAINTENANCE MANUAL TO THE ARCHITECT/ENGINEER

AFTER ALL TESTS AND ADJUSTMENTS HAVE BEEN MADE. FINAL PAYMENT WILL NOT BE MADE UNTIL THIS

MANUAL HAS BEEN APPROVED AND DELIVERED TO THE OWNER. THE MANUAL SHALL INCLUDE BUT NOT BE

LIMITED TO:

1. CONTRACTOR ADDRESS AND PHONE NUMBER.

2. MANUFACTURER AND LOCAL REPRESENTATIVE ADDRESS AND PHONE NUMBER.

3. START-UP, SHUTDOWN AND SEASONAL CHANGEOVER PROCEDURES FOR ALL MECHANICAL EQUIPMENT.

4. ONE COPY OF EACH APPROVED SHOP DRAWINGS, INCLUDING ENGINEER APPROVAL SHEET.

5. MANUFACTURERS' MANUAL AND PARTS LIST.

6. FILTER AND V-BELT LIST.

7. TEST AND BALANCE REPORT.

8. STATE OR CITY TESTS, APPROVAL, OR ACCEPTANCE OF SYSTEMS (THIS SHALL INCLUDE EQUIPMENT

INSTALLATION START-UPS.)

SECTION 211313 - SPRINKLER SYSTEM

MODIFY EXISTING SPRINKLER SYSTEM AND HEAD LOCATIONS TO ACCOMMODATE NEW PARTITIONS, SOFFITS,

DROPS, CEILING TYPES AND HEIGHTS, ETC.

COMPLY WITH ALL REQUIREMENTS OF THE GOVERNMENTAL AGENCIES AND AUTHORITIES HAVING

JURISDICTION OVER THE PREMISES. DESIGN AND INSTALLATION SHALL COMPLY WITH NFPA #13 AND ALL

APPLICABLE STATE AND LOCAL LAWS AND ORDINANCES. SUBCONTRACT THE WORK TO A LICENSED

CONTRACTOR.

SUBMIT SHOP DRAWINGS TO INDICATE DESIGN, LAYOUT, MATERIALS, AND INSTALLATION. SUBMIT TO THE

ARCHITECT/ENGINEER, AND TO AUTHORITIES HAVING JURISDICTION AND OBTAIN THEIR APPROVAL PRIOR TO

EXECUTION OF THE WORK OF THIS SECTION. SHOP DRAWINGS SHALL SHOW PIPING AND SPRINKLER HEADS,

CEILING CONSTRUCTION AND HEIGHTS, LIGHTS, MECHANICAL DIFFUSERS, SOFFITS AND OTHER CEILING

DROPS.

REUSE EXISTING SPRINKLER HEADS. MATCH NEW SPRINKLER HEADS TO EXISTING.

COORDINATE SPRINKLER SYSTEM WORK WITH OTHER TRADES TO CLEAR PIPING, LIGHTING, DUCTWORK AND

STRUCTURAL MEMBERS.

NOTIFY LANDLORD/OWNER PRIOR TO DRAINING AND/OR REFILLING SPRINKLER SYSTEM. DISCONNECT

EXISTING SYSTEM FROM MAIN SYSTEM, PERFORM THE WORK, TEST, AND RECONNECT TO THE MAIN SYSTEM.

IN ALL AREAS WITH CEILINGS, INSTALL PIPING ABOVE CEILING UNLESS OTHERWISE DIRECTED. LOCATE

SPRINKLER HEADS CENTERED IN CEILING PANELS. LOCATE DRAIN LINES TO PREVENT WATER DAMAGE IN

BUILDING.

SECTION 220500/230500 - COMMON WORK RESULTS

PIPE SLEEVES AND FIRE STOPPING:

THIS CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING, SETTING AND PROPER LOCATION OF ALL

SLEEVES REQUIRED FOR PLUMBING WORK. ALL SLEEVES SHALL BE OF SUFFICIENT SIZE TO PERMIT PIPE

MOVEMENT OF EXPANSION AND CONTRACTION AND TO ACCOMMODATE PIPE INSULATION.

HOLES FOR PIPING THROUGH CONCRETE FLOORS AND WALLS SHALL BE SCHEDULE 40 STEEL PIPE, SECURED

TO WALL.

PIPES SHALL NOT BE INSTALLED THROUGH FOOTINGS, BEAMS, OR COLUMNS EXCEPT AS APPROVED BY

ARCHITECT.

FIRESTOPPING IS DEFINED HEREIN AS THE PROCESS OF FURNISHING AND INSTALLING MATERIAL, OR

COMBINATION OF MATERIALS, IN VARIOUS CONSTRUCTION TO MAINTAIN AN EFFECTIVE BARRIER AGAINST THE

SPREAD OF FLAME, SMOKE, AND GASES AND TO RETAIN THE INTEGRITY OF TIME-RATED CONSTRUCTION.

INSTALL FIRESTOP FOR ALL PIPING AND DUCT PENETRATIONS THROUGH FLOOR SLAB, THROUGH FIRE-RATED

PARTITIONS, OR FIRE WALLS. 3-M PRODUCTS ARE ACCEPTABLE.

SECTION 220529/230529 - HANGERS AND SUPPORT

ALL FERROUS PIPING SHALL BE HUNG WITH ADJUSTABLE SWIVEL RING AND HANGERS. MASON FIG. 400 OR

APPROVED EQUAL.

ALL COPPER PIPING SHALL BE HUNG WITH ADJUSTABLE SWIVEL RING, COPPER PLATED HANGERS FOR

NOMINAL TUBING AS REQUIRED. MASON FIG. 500 OR APPROVED EQUAL.

PROVIDE HANGER RODS OF THE PROPER LENGTH AND SIZE FOR ALL HANGERS.

UTILIZE WALL BRACKETS, BEAMS OR OTHER CONSTRUCTION TO SUPPORT HANGER RODS WITH APPROPRIATE

BEAM CLAMPS OR OTHER STRUCTURAL ATTACHMENTS AS APPROVED BY THE ARCHITECT. SHOT-IN ANCHORS

WILL NOT BE ACCEPTED.

THE CONTRACTOR SHALL FURNISH AND INSTALL MISCELLANEOUS STEEL MEMBERS FOR SUPPORT OF PIPING

WHERE REQUIRED. STANDARD CONNECTIONS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION SHALL

BE UTILIZED. WELDING TO BUILDING STEEL IS NOT ALLOWED.

HANGERS FOR COPPER LINES SHALL BE SPACED NOT OVER 10'-0" ON CENTERS AND CLOSER WHERE

REQUIRED TO ACCOMMODATE CONCENTRATED LOADS AND TO LIMIT DEFLECTION TO 1/4". HANGERS SHALL

BE INSTALLED AT ALL CHANGES IN DIRECTION OF PIPING.

FIXTURES, FIXTURE SUPPORTS, FIXTURE TRIMMINGS, ETC., SHALL BE SECURED WITH 1/2" BRASS THROUGH

BOLTS, EXPANSION BOLTS OR TOGGLE BOLTS IN ACCORDANCE WITH WALL MATERIAL AND AS REQUIRED TO

SECURELY ANCHOR FIXTURE TO WALL. EXPOSED HEADS AND CAP NUTS SHALL BE CHROMIUM PLATED.

HANGERS FOR PIPE WITH VAPOR BARRIER JACKETS SHALL BE SIZED TO ACCOMMODATE INSULATION AND

SHALL BE INSTALLED WITH SHEET METAL SHIELDS.

PROVIDE SUPPLEMENTAL STEEL BRACING TO PREVENT PIPE SWAY (HORIZONTAL MOVEMENT). INSTALL IN

SUCH A MANNER TO ALLOW PIPE EXPANSION AND CONTRACTION (LATERAL MOVEMENT). SEISMIC BRACING

SHALL BE PER CODE AND SMACNA STANDARDS.

SECTION 220548/230548 - VIBRATION ISOLATORS

CONTRACTOR SHALL PROVIDE ISOLATION SYSTEMS SO THAT OBJECTIONABLE NOISES OR VIBRATIONS WILL

NOT BE TRANSMITTED THROUGH FOUNDATIONS, FLOORS, WALLS, COLUMNS, PIPING AND DUCTS, ETC. ALL

ISOLATION SYSTEMS PROPOSED SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT.

EVERY ROTATING AND RECIPROCATING ITEM OF EQUIPMENT, THEIR COMPONENTS AND MATERIALS USED FOR

CONVEYANCE, SHALL BE PROVIDED WITH THE PROPER ISOLATION EQUIPMENT. FACTORY PACKAGED

EQUIPMENT SHALL BE FURNISHED COMPLETE WITH INTEGRAL ISOLATORS.

SECTION 220700/230700 - PIPE INSULATION

AS MANUFACTURED BY OWENS-CORNING, JOHNS-MANVILLE, OR ARMSTRONG. ALL INSULATION SHALL HAVE

COMPOSITE FIRE AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE ASTM E-84, NFPA 255 AND UL 723

NOT EXCEEDING FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED RATING OF 50. INSULATION SHALL BE

CONTINUOUS THRU WALLS, INCLUDING WHERE INSTALLED INSIDE OF WALL CAVITIES.

INSERTS SHALL BE INSTALLED AT ALL HANGERS OR SUPPORTS. INSERTS SHALL CONSIST OF RIGID PIPE

INSULATION OF EQUAL THICKNESS TO THE ADJOINING INSULATION, CORROSION RESISTANT RIGID SHIELD OR

SADDLE AND SHALL BE PROVIDED WITH VAPOR BARRIER WHERE REQUIRED. ELGEN, INSULCOUSTIC OR

APPROVED EQUAL.

PRE-FORMED, FIBERGLASS PIPE INSULATION WITH SELF-SERVICE JACKET INCLUDING SELF-SEALING LAPS,

AND VAPOR BARRIER SHALL BE PROVIDED FOR THE FOLLOWING SYSTEMS. FOR ALL COLD WATER AND HOT

WATER PIPING, THICKNESS SHALL BE 1" THICK.

ALL VALVES AND FITTINGS SHALL BE INSULATED WITH ZESTON PRE-MOLDED PVC COVERS WITH GLASS FIBER

INSERT TO SAME THICKNESS AS PIPE INSULATION. TAPE JUNCTION OF COVERS AND PIPE INSULATION. SEAL

THROAT OF COVERS WITH MASTIC FOR ALL COLD WATER LINES IN BUILDING.

SECTION 221000/231000 - PIPING MATERIALS

ALL PIPE AND FITTINGS SHALL BE SMOOTH INSIDE, STRAIGHT, FREE FROM WELD OR SOLDER FLAWS, BLISTERS

OR OTHER DEFECTS. EACH LENGTH OF PIPE AND EACH FITTING SHALL HAVE CAST, STAMPED OR INDELIBLY

MARKED ON IT THE MAKER'S MARK OR NAME AND THE WEIGHT AND QUALITY OF THE PRODUCT WHERE SUCH

MARKING IS REQUIRED BY THE APPROVED STANDARD THAT APPLIES. ALL SIZES SHOWN ON PLANS ARE I.D.

REFERENCES TO ANSI AND OTHER STANDARDS SHALL BE LATEST EDITIONS.

PIPING:

ALL SANITARY WASTE PIPES IN BUILDING ABOVE GROUND AND VENTS ABOVE GROUND SHALL BE PVC PLASTIC

PIPE OR CAST IRON PIPE (BELL & SPIGOT OR HUBLESS) WITH 304 STAINLESS STEEL COUPLING. PLASTIC PIPE

AND FITTINGS SHALL NOT BE INSTALLED IN THE CEILING SPACES USED FOR RETURN AIR PLENUMS UNLESS

COVERED WITH A MINIMUM OF 1" FIBERGLASS INSULATION AS SPECIFIED IN SECTION 220700/230700.

UNDERGROUND DRAINAGE AND VENT PIPING INSIDE THE BUILDING SHALL BE SCHEDULE 40 SOLID WALL PVC

PLASTIC PIPE OR SERVICE WEIGHT HUB AND SPIGOT CAST IRON SOIL PIPE, THOROUGHLY COATED WITH COAL

TAR VARNISH INSIDE AND OUTSIDE, CONFORMING TO ASTM A74 AND CS188 AND BEARING THE MARK OF THE

CAST IRON SOIL PIPE INSTITUTE.

HORIZONTAL SOIL, WASTE, AND DRAIN PIPE SHALL BE SLOPED AT 1/4" PER FOOT EXCEPT WHEN THE PIPE IS

LARGER THAN 3" WHICH MAY BE INSTALLED WITH A SLOPE OF NOT LESS THAN 1/8" PER FOOT UNLESS

OTHERWISE NOTED.

ALL ABOVE GROUND DOMESTIC COLD AND DOMESTIC HOT WATER PIPES INSIDE BUILDING 3” AND SMALLER

SHALL BE TYPE “L” HARD TEMPER COPPER TUBING CONFORMING TO ASTM B88.

FITTINGS:

FITTINGS FOR CAST IRON SOIL PIPE, BELL AND SPIGOT, SHALL BE CAST IRON CONFORMING TO ANSI B16-12

AND CS-188, STANDARD WEIGHT, COATED INSIDE AND OUT WITH HEAVY COAL TAR VARNISH. JOINTS SHALL BE

MADE WITH VULCANIZED RUBBER OR NEOPRENE CONFORMING TO ASTM C-564.

PVC FITTINGS FOR PVC PIPING.

FITTINGS FOR CAST IRON SOIL PIPE (HUBLESS) SHALL BE MADE WITH 304 STAINLESS STEEL COUPLINGS.

GASKETS TO CONFORM TO CISPI 301.

FITTINGS FOR RIGID COPPER TUBING SHALL BE WROUGHT COPPER SOLDER FITTINGS CONFORMING TO ANSI

B16.22 AND STM B-75.

JOINTS:

SCREWED PIPE JOINTS SHALL HAVE FULL CLEAN CUT THREADS CONFORMING TO ANSI B2.1, WITH ENDS OF

PIPE REAMED, FILED AND ALL BURRS REMOVED. JOINTS SHALL BE MADE WITH GRAPHITE BASE PIPE JOINT

COMPOUND OR APPROVED EQUAL COMPOUND. NOT MORE THAN THREE EXPOSED THREADS WILL BE

PERMITTED. PACKING THREADS WITH LAMP WICK OR OTHER MATERIAL WILL NOT BE PERMITTED. FITTINGS

AND PIPE SHALL BE FREE FROM OIL AND GREASE.

COPPER PIPE JOINTS SHALL BE SOLDERED WITH 95% TIN AND 5% ANTIMONY SOLDER USING A

NON-CORROSIVE FLUX, EXCEPT JOINTS BELOW FLOOR SLABS ON GRADE SHALL BE BRAZED.

PVC PIPE JOINTS SHALL BE SOLVENT WELD WITH SOLVENT CEMENT CONFORMING TO ASTM D2855 AND D2564.

UNIONS ARE REQUIRED FOR CONNECTING ALL EQUIPMENT. UNIONS 2" OR SMALLER SHALL BE SCREWED OR

SOLDER TYPE, WITH SPHERICAL GROUND JOINT. UNIONS 2-1/2" AND LARGER SHALL BE OF THE BOLTED

FLANGED TYPE. UNIONS SHALL BE AS MANUFACTURED BY STOCKHAM OR APPROVED EQUAL.

INSTALL INSULATING TYPE DIELECTRIC UNIONS FOR CONNECTING DISSIMILAR PIPE.

PIPE LABELS:

ATTACHED SELF-ADHESIVE, PRINTED PLASTIC, PIPE LABELS TO ALL NEW DOMESTIC PIPING IN CONCEALED

AREAS. SPACING SHALL BE EVERY 20' AND NEXT TO EACH WALL PENETRATION, ACCESS DOOR, OR MAJOR

EQUIPMENT. LABEL SHALL INCLUDE A MINIMUM OF 1/2" HIGH LETTERS AND FLOW ARROWS.

VALVES:

VALVES SHALL BE OF ONE MANUFACTURER THROUGHOUT INSTALLATION. VALVES SHALL BE RATED 200 LBS.

FOR COLD WATER SERVICE. ALL VALVES SHALL BE FULL-PORT BALL VALVES. WHERE VALVES AND PIPING

SHALL BE INSULATED, EXTENDED STEMS SHALL BE PROVIDED ON VALVES.

SOLDER JOINT VALVES FOR COPPER TUBING:

BALL VALVES - BRONZE/BRASS BALL, SCREWED TFE SEAT, NIBCO T-580 / S-580.

CHECK VALVES - BRONZE SWING CHECK, NIBCO T-413.

TESTING AND FLUSHING:

ALL WATER PIPING SHALL BE HYDROSTATICALLY TESTED, AT 1-1/2 TIMES OPERATING PRESSURE (MIN. 125 PSI),

LEAKS REPAIRED AND SYSTEM RETESTED UNTIL PROVED RIGHT BEFORE BACKFILLING, OR CONCEALING OF

INSULATED PIPE. WASTE PIPE SHALL BE TESTED AT A MINIMUM OF 10' OF WATER. NOTIFY

ARCHITECT/ENGINEER A MINIMUM OF 48 HOURS BEFORE PERFORMING TESTS. PROJECT SHALL BE TESTED IN

A MAXIMUM OF 3 TESTS.

ALL POTABLE WATER SYSTEM PIPING AND COMPONENTS SHALL BE FLUSHED AND STERILIZED AFTER

CLEANING. STERILIZE AND CHLORINATE IN ACCORDANCE WITH STATE AND LOCAL HEALTH DEPARTMENT

STANDARDS, SUBMIT SAMPLES TO BE TESTED AND PROVIDE REPORT TO ARCHITECT/ENGINEER.

SECTION 224000 - PLUMBING FIXTURES

PLUMBING FIXTURES SHALL BE FURNISHED AND INSTALLED IN A WORKMANLIKE MANNER WITH PROPER

CONNECTIONS TO SUPPLY AND DRAINAGE PIPING. ALL FIXTURES SHALL BE FREE OF DEFECTS AND FLAWS

AND SHALL OPERATE PERFECTLY WHEN INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S

DIRECTIONS.

TRAPS:

EACH FIXTURE AND EACH PIECE OF EQUIPMENT REQUIRING CONNECTION TO THE SANITARY DRAINAGE

SYSTEM SHALL BE EQUIPPED WITH WATER SEALED TRAP. EACH TRAP SHALL BE PLACED AS NEAR THE

FIXTURE AS POSSIBLE.

TRAPS EXPOSED TO VIEW IN FINISHED SPACES SHALL BE CHROMIUM PLATED CAST BRASS WITH CLEANOUT.

TRAPS INSTALLED ON THREADED PIPE SHALL BE RECESS DRAINAGE PATTERN.

VENT LINES:

MINIMUM SIZES OF FIXTURE VENTS SHALL BE INSTALLED AS SHOWN ON THE DRAWINGS. CONNECTING VENTS

SHALL BE SIZED AND RUN THROUGH ROOF OR CONNECTION TO MAIN VENT SHOWN ON PLANS. VENTS MUST

BE CONNECTED INTO STACK VENTS ABOVE HIGHEST FIXTURE.

SECTION 230593 - TESTING AND BALANCING

AFTER THE HEATING AND COOLING SYSTEMS ARE OPERABLE, OPERATE THE SYSTEMS AND MAKE

ADJUSTMENTS IN THE CONTROLS AND EQUIPMENT AS REQUIRED TO BALANCE THE SYSTEMS TO DELIVER THE

REQUIRED DESIGN AIR QUANTITIES AND TEMPERATURES. PROVIDE, IN TRIPLICATE, TYPEWRITTEN TEST AND

BALANCE REPORT, INDICATING ACTUAL READINGS AT ALL INLETS AND OUTLETS IN THE SUPPLY, RETURN AND

EXHAUST SYSTEMS. DELIVER TO ARCHITECT/ENGINEER. USE NEBB REPORTING FORMS FOR REPORT.

SECTION 230700 - HVAC INSULATION

DUCT INSULATION SHALL BE AS MANUFACTURED BY OWENS-CORNING, JOHNS MANSVILLE, OR CERTAIN-TEED.

ALL INSULATION SHALL HAVE COMPOSITE FIRE AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE

ASTM E-84, NFPA 255 AND UL 723 NOT EXCEEDING FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED

RATING OF 50.

INTERIOR DUCTWORK (DUCTWORK IN MECHANICAL ROOMS SHALL BE CONSIDERED AS CONCEALED):

· ROUND AND RECTANGULAR SUPPLY DUCT IN CONCEALED AREAS SHALL BE COVERED WITH 1-1/2" THICK

3/4LB. DENSITY FIBERGLASS BLANKET DUCT WRAP WITH FACTORY-APPLIED FRK FACING, AND VAPOR

BARRIER.

· THE FIRST 10' OF ALL SUPPLY, AND RETURN DUCT AFTER ROOFTOP UNIT SHALL BE LINED WITH 1" THICK, 2

LB. DENSITY GLASS TEXTILE FIBER LINER FOR NOISE REDUCTION. OVERLAP TRANSITION FROM LINER TO

WRAP BY AT LEAST 12".

· EXHAUST FAN DUCTWORK SHALL BE COVERED IN 1" THICK 3/4" LB. DENSITY FIBERGLASS BLANKET DUCT

WRAP WITH FACTORY-APPLIED FRK FACING, AND VAPOR BARRIER FROM ROOF PENETRATION TO 1'-0"

BEYOND THE BACKDRAFT DAMPER.

LINER SHALL MEET THE STANDARDS OF NFPA 90A.

SECTION 230900 - CONTROLS

PROVIDE ALL TEMPERATURE CONTROLS IN ACCORDANCE WITH RECOMMENDATIONS OF THE EQUIPMENT

MANUFACTURER.

1. FURNISH COMPLETE CONTROL DIAGRAMS SHOWING ALL ASPECTS OF THE OPERATION.

2. CONTROLS SHALL BE TYPE AS INDICATED ON THE PLANS.

3. PROVIDE ALL WIRING, TUBING, ETC. REQUIRED FOR COMPLETE AND OPERATING SYSTEM.

4. ALL CONTROLS AND SAFETY DEVICES SHALL BE THOROUGHLY CHECKED TO ASSURE PROPER OPERATION

AND PROTECTION.

SECTION 231000 - DUCTWORK AND ACCESSORIES

SHEET METAL DUCT WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH LATEST EDITION OF LOCAL

CODES, ASHRAE AND SMACNA STANDARDS FOR LOW PRESSURE DUCT SYSTEMS. ALL CONCEALED LOW

PRESSURE ROUND DUCT SHALL BE SPIRAL CONSTRUCTION OR CONSTRUCTED WITH A LONGITUDINAL SEAM

AND SCREWED OR POP RIVETED TOGETHER.

DUCTS AND CASINGS SHALL BE MECHANICALLY TIGHT AND SUBSTANTIALLY AIRTIGHT. ALL SEAMS SHALL BE

SEALED OR GLUED PER MANUFACTURER'S RECOMMENDATIONS.

SIZES SHOWN ON THE PLAN INDICATE THE FREE AREA OF THE DUCT UNLESS OTHERWISE NOTED.

TURNING VANES SHALL BE INSTALLED IN EACH BEND OR TURN IN ALL SUPPLY, EXHAUST AND RETURN AIR

DUCTS. INSTALL SPLITTER DAMPERS, MANUAL DAMPERS, ETC., WHERE NOTED ON THE PLANS OR WHERE

REQUIRED.

ACCESS DOORS 18" X 18" OR AS LARGE AS DUCT WILL ALLOW, SHALL BE INSTALLED WHERE REQUIRED TO

PROVIDE ACCESS TO WORKING PARTS, FIRE DAMPERS, FUSIBLE LINKS, FILTERS, COILS, ETC.

WHEREVER SHEET METAL DUCTWORK IS INSTALLED, ALL DUCT CONNECTIONS TO EQUIPMENT WITH BLOWERS

SHALL BE MADE WITH FLEXIBLE DUCT CONNECTION A MINIMUM OF 3" WIDE OF FIRE RESISTANT MATERIAL

THAT IS ABSOLUTELY WATERTIGHT AND AIRTIGHT. FABRIC SHALL WITHSTAND TEMPERATURE OF 200

DEGREES F CONTINUOUSLY. CONNECTION OF FLEXIBLE DUCT TO SHEET METAL SHALL BE MADE AIRTIGHT

WITH RIVETS OR SCREWS AS REQUIRED. VENTGLAS BY VENTFABRICS, INC, OR NEOPRENE FABRIDUCT BY

ELGEN. COMPLY WITH NFPA 90A. FLEXIBLE DUCT SHALL BE A MAXIMUM OF 5'-0" LONG AT DIFFUSERS

CONNECTIONS.

SQUARE OR RECTANGULAR BALANCING DAMPERS SHALL BE STANDARD-LEAKAGE DAMPERS WITH OPPOSED

3V BLADE TYPE. GREENHECK TYPE VCD-15 OR APPROVED EQUAL. ROUND BALANCING DAMPERS SHALL BE

GREENHECK MBDR-50. FURNISH POSITIVE LOCKING QUADRANT FOR MANUAL DAMPERS TO HOLD DAMPER

BLADES SECURELY IN THE DESIRED POSITION AND SHALL INDICATE THE RELATIVE POSITION OF THE DAMPER

BLADES. QUADRANTS SHALL BE MOUNTED IN ACCESSIBLE LOCATIONS. QUADRANTS SHALL BE VENTFABRICS,

INC., ELGEN, OR YOUNG REGULATOR.

SQUARE OR RECTANGULAR EXHAUST BACKDRAFT DAMPERS (BD) SHALL BE GREENHECK BAROMETRIC TYPE

BR-30 OR APPROVED EQUAL. DAMPER SHALL START TO OPEN AT 0.05" WG. MAX PRESSURE LOSS OF 0.1" AT

600 FPM WHEN FULLY DUCTED.

ME

CH

AN

IC

AL

/

EL

EC

TR

IC

AL

E

NG

IN

EE

R

Olsso

n A

sso

cia

te

s

21

11

S

ou

th

6

7th

S

tre

et

Su

ite

2

00

Om

ah

a, N

E 6

81

06

40

2.3

41

.1

11

6

700 Q

S

t.

Lincoln, N

E 68508

T: 402 476 7331 F

: 402 476 8341

SHA PROJECT

NO.

DE

SIG

N E

NG

IN

EE

R:

PR

OJE

CT

E

NG

IN

EE

R:

DR

AW

N B

Y:

IS

SU

ED

:

RE

VIS

IO

NS

:

Copyright SINCLAIR HILLE ARCHITECTSC

PR

OJE

CT

C

ON

SU

LT

AN

TS

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

1/17/2017 11:07 A

M

F:\2016\3501-4000\016-3521\40-design\AutoCAD\final plans\Sheets\MECH\Mechanical\M_SPC_63521.dwg

16073

01/11/2017

Sylv

an L

earn

ing

Cen

ter

Yank

ee R

idge

Com

mer

cial

Cen

ter

OA

P

RO

JE

CT

#:

016-3521

13 14

Mech

an

ical S

pecificatio

ns

M401

BR

M

TJR

SR

R

EXISTING, DEMO & NEW LEGEND

DUPLEX RECEPTACLE; MOUNT AT 18" TO CENTER OF DEVICE AFF UNLESS OTHERWISE NOTED. FLOOR MOUNTED DUPLEX RECEPTACLE

SINGLE RECEPTACLE; MOUNT AT 18" TO CENTER OF DEVICE AFF UNLESS OTHERWISE NOTED. FLOOR MOUNTED FOUR PLEX RECEPTACLE

CEILING MOUNTED DUPLEX RECEPTACLE

CEILING MOUNTED FOUR PLEX RECEPTACLE

GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE ELECTRICAL DISTRIBUTION PANEL

DUPLEX RECEPTACLE. ON EMERGENCY CIRCUIT RECESSED MOUNTED ELECTRICAL PANEL

FOUR PLEX RECEPTACLE. ON EMERGENCY CIRCUIT SURFACE MOUNTED ELECTRICAL PANEL

WATERPROOF RECEPTACLE ELECTRICAL POWER TRANSFORMER

ISOLATED GROUND RECEPTACLE FUSED DISCONNECT SWITCH

220V RECEPTACLE NON-FUSED DISCONNECT SWITCH

COMBINATION MAGNETIC STARTER AND DISCONNECT SWITCH

STARTER/MOTOR CONTROLLER

ELECTICAL MOTOR - SINGLE PHASE

GFI

WP

IG

FOUR PLEX RECEPTACLE; MOUNT AT 18" TO CENTER OF DEVICE AFF UNLESS OTHERWISENOTED.

SPECIAL-PURPOSE OUTLET. LETTER DESIGNATES TYPE, SEE SPECIAL CONNECTIONSCHEDULE FOR REQUIREMENTS

SURFACE RACEWAY WITH OUTLETS AS INDICATED ON PLANS,MOUNTED AT 18" TO CENTEROF DEVICE AFF UNLESS OTHERWISE NOTED ELECTRICAL MOTOR - THREE PHASE

ELECTRICAL SYMBOL LEGEND

J

J

J

WALL MOUNTED JUNCTION BOX

CEILING MOUNTED JUNCTION BOX

FLOOR MOUNTED JUNCTION BOX

T

R

B

RELAY

BATTERY PACK

POWER DEVICES

LIGHTING

CEILING MOUNTED OR RECESSED LIGHT FIXTURE; LABEL INDICATES FIXTURE TYPE

PENDANT MOUNTED LIGHT FIXTURE; LABEL INDICATES FIXTURE TYPE

WALL MOUNTED LIGHT FIXTURE; LABEL INDICATES FIXTURE TYPE

1'x4' TYPICAL CEILING MOUNTED FLUORESCENT FIXTURE; LABEL INDICATES FIXTURE TYPE

1'x4' TYPICAL PENDANT MOUNTED FLUORESCENT FIXTURE; LABEL INDICATES FIXTURE TYPE

1'x4' TYPICAL WALL MOUNTED FLUORESCENT FIXTURE; LABEL INDICATES FIXTURE TYPE

1'x2' TYPICAL WALL MOUNTED FLUORESCENT FIXTURE; LABEL INDICATES FIXTURE TYPE

FLUORESCENT INDUSTRIAL STRIP LIGHT FIXTURE; LABEL INDICATES FIXTURE TYPE

FLUORESCENT STRIP LIGHT FIXTURE; LABEL INDICATES FIXTURE TYPE

FLUORESCENT UNDER CABINET FIXTURE; LABEL INDICATES FIXTURE TYPE

DOUBLE FACED CEILING OR WALL-MOUNTED, EXIT SIGN WITH EMERGENCY POWER BACK UP.

SINGLE FACED CEILING OR WALL MOUNTED, EXIT SIGN WITH EMERGENCY POWER BACK UP.

COMBINATION EXIT AND EMERGENCY LIGHT

DIRECTION ARROW FOR EMERGENCY LIGHT

CEILING OR WALL MOUNTED, SELF-CONTAINED EMERGENCY LIGHT UNIT; FIXTURE SHALLMONITOR LIGHTING CIRCUIT IN AREA.

2'x4' FLUORESCENT LIGHT FIXTURE; LABEL INDICATES FIXTURE TYPE

2'x2' FLUORESCENT LIGHT FIXTURE; LABEL INDICATES FIXTURE TYPE

2'x4' TYPICAL FLUORESCENT FIXTURE - NORMAL/EMERGENCY

2'x2' TYPICAL FLUORESCENT FIXTURE - NORMAL/EMERGENCY

1'x4' TYPICAL CEILING MOUNTED FLUORESCENT FIXTURE - NORMAL/EMERGENCY

CEILING MOUNTED OR RECESSED TYPICAL FIXTURE - NORMAL/EMERGENCY

BRANCH CIRCUIT WIRING CONCEALED IN WALLS OR CEILING

BRANCH CIRCUIT WIRING CONCEALED IN FLOOR

CEILING OR WALL-MOUNTED OCCUPANCY SENSOR

CEILING OR WALL-MOUNTED PHOTO CELL

OSOS

PC PC

SINGLE-POLE SWITCH

DOUBLE-POLE SWITCH

3-WAY SWITCH

4-WAY SWITCH

SINGLE-POLE SWITCH AND PILOT LIGHT

SINGLE POLE MANUAL MOTOR STARTER WITH THERMAL ELEMENT

SINGLE-POLE DIMMER SWITCH

SINGLE-POLE KEYED SWITCH

LOW VOLTAGE SWITCH

FAN SWITCH

MOMENTARY CONTACT SWITCH

PUSHBUTTON SWITCH

COMBINATION PUSHBUTTON SWITCH

MUSHROOM EMERGENCY SHUT-OFF SWITCH.

2

3

4

P

TE

D

K

L

F

M

LIGHTING CONTACTOR

TIME CLOCK, AS INDICATED ON PLANS

PHOTO CELL, AS INDICATED ON PLANS

LC

TC

PC

SPECIAL SYSTEMS

DATA/TELEPHONE OUTLET, FLOOR MOUNTED

SPEAKER, WALL MOUNTEDCOMBINATION DATA/TELEPHONE OUTLET

SPEAKER, CEILING MOUNTEDTELEPHONE

ELECTRIC VALVE

INSTRUMENT DEVICE

DATA OUTLET; NUMBER INDICATES QUANTITY, BLANK INDICATES SINGLE OUTLET. MOUNTEDAT 18" TO CENTER OF DEVICE AFF UNLESS OTHERWISE NOTED.

INTERIOR SIREN ALARMDATA, CEILING MOUNTED

CLOCK, WALL MOUNTEDDATA, FLOOR MOUNTED

CLOCK, CEILING MOUNTEDTELEVISION OUTLET, CEILING MOUNTED

CABLE TRAY

GROUND BAR

TV

TELEVISION CABLE OUTLET; MOUNT AT 18" TO CENTER OF DEVICE AFF UNLESS OTHERWISENOTED

TV

S

E

I

S

C

FIRE ALARM

MAGNETIC DOOR HOLD DEVICE

SPRINKLER FLOW SWITCH

SPRINKLER TAMPER SWITCH

EXTERIOR REMOTE FLASHING STROBE LIGHT

M

FS

TS

FMANUAL PULL STATION; MOUNT ACCORDING TO MOUNTING HEIGHT DETAIL AT 46" TO CENTEROF DEVICE AFF. ADA COMPLIANT

FHORN & STROBE; MOUNT SO BOTTOM OF DEVICE IS AT 80" AFF UNNLESS OTHERWISENOTED. ADA COMPLIANT

STROBE; MOUNT SO BOTTOM OF DEVICE IS AT 80" AFF UNNLESS OTHERWISE NOTED. ADACOMPLIANTF

FSPEAKER & STROBE; MOUNT SO BOTTOM OF DEVICE IS AT 80" AFF UNNLESS OTHERWISENOTED. ADA COMPLIANT

MULTI-OUTLET FLOOR BOX, SEE FLOOR BOX SCHEDULE FOR REQUIREMENTS.FB

HALFTONE LINES INDICATE EXISTING DEVICES TO REMAIN

BOLD DASHED LINES INDICATE DEVICES TO BE REMOVED.

NEW DEVICES

S

C

MOTORIZED DAMPER

SECURITY DEVICES

FIRE ALARM VOICE WALL MOUNT SPEAKER

SMOKE DETECTOR

DUCT MOUNTED SMOKE DETECTOR

THERMAL HEAT DETECTOR

POST INDICATOR VALVE

BELL

SHUTDOWN RELAY WITH REMOTE TEST SWITCH

SHUTDOWN RELAY AND TEST SWITCH

FIRE ALARM CONTROL PANELFACP

D

HD

PIV

B

R

RT

RAP REMOTE ANNUNCIATOR PANEL

SMOKE DAMPER

FIRE DAMPER

COMBINATION FIRE AND SMOKE DAMPER

FIRE ALARM VOICE CEILING MOUNT SPEAKERS

S

WAP WIRELESS ACCESS POINT, CEILING MOUNTED

X

ABBREVIATIONS/MODIFIERS

SHEET NOTE TAG, LABELINDICATES NOTE NUMBER

A AMPERE

C CONDUIT

P POLE

W WIRE

T TELEPHONE SERVICE

FA FIRE ALARM

NF NON-FUSED

WP WEATHERPROOF

C/B CIRCUIT BREAKER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

CIR CIRCUIT

XFMR TRANSFORMER

MD MOTORIZED DAMPER

PE PRIMARY ELECTRIC SERVICE

SE SECONDARY ELECTRIC SERVICE

RTU ROOFTOP UNIT

TCP TEMPERATURE CONTROL PANEL

SD SMOKE DAMPER

IG ISOLATED GROUND

RMC RIGID METALLIC CONDUIT

EMT ELECTRIC METALLIC TUBING

AD AUTOMATIC DAMPER

UGE UNDERGROUND ELECTRICAL

FMC FLEXIBLE METALLIC TUBING

TV TELEVISION

EF EXHAUST FAN

PVC POLYVINYL CHLORIDE CONDUIT

REF ROOF EXHAUST FAN

AHU AIR HANDLING UNIT

CUH CABINET UNIT HEATER

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

GFI GROUND FAULT INTERRUPTER

MAU MAKE-UP AIR UNIT

WG WIRE GUARD

S&P SPACE AND PROVISION

(E) EXISTING DEVICES TO REMAIN

(RE) REMOVE EXISTING

(RL) RELOCATE EXISTING

(ER) NEW LOCATION OF EXISTING RELOCATED

NL NIGHT LIGHT

NR NEW TO REPLACE EXISTING

RR REMOVE AND REPLACE ON NEW SURFACE

* ABOVE COUNTER

ATS AUTOMATIC TRANSFER SWITCH

VFC VARIABLE FREQUENCY CONTROLLER

VFD VARIABLE FREQUENCY DRIVE

FB FLOOR BOX

PTD ELECTRIC PAPER TOWEL DISPENSER

HD HAND DRYER

TP TAMPER PROOF

AFCI ARC FAULT CIRCUIT INTERUPTER

MOTION DETECTOR, CEILING MOUNTED

MOTION DETECTOR, WALL MOUNTED

M

M

ELECTRIC DOOR STRIKER

VIDEO CAMERA, WITH MOUNTING HARDWARE

VIDEO MONITOR

VIDEO RECORDER

ES

VM

VR

ML

CL

ELECTRIC MAGNETIC LOCK

ELECTRIC CYLINDER LOCK

CARD READERCR

REX REQUEST TO EXIT

DOOR CONTACT - RECESSED

DOOR CONTACT - SURFACE MOUNT

DCM

ACP ACCESS CONTROL PANEL

DOOR CONTROL MODULE

EMERGENCY DOOR RELEASE BUTTON

PANIC BUTTON

SECURITY BUZZER HORN

INTERCOM SUBSTATION

INTERCOM SUBSTATION WITH CAMERA

INTERCOM MASTER STATION

GLASS BREAK SENSOR

POWER TRANSFER HINGE

BRANCH CIRCUIT COPPER CONDUCTOR AND CONDUIT SIZE

PROTECTIONDEVICE RATING

(AMPS)

UNLESS OTHERWISE NOTED ON THE DRAWINGS.

ALL CONDUCTORS SHOWN IN THIS TABLE ARE BASED ON THREE CURRENT CARRYING CONDUCTORSIN A RACEWAY OR CABLE. CONDUCTORS SHALL BE DERATED IN ACCORDANCE WITH THE NEC IF 4 ORMORE CONDUCTORS ARE PLACED IN A RACEWAY OR CABLE.

THE CONDUCTORS SHOWN IN THIS TABLE ARE BASED ON AN AMBIENT TEMPERATURE OF86°F. FOR TEMPERATURES ABOVE 86°F THE CONDUCTOR AMPACITY SHALL BE DERATEDIN ACCORDANCE WITH THE NEC.

* =

*

REQUIREDCONDUCTOR

SIZE

EQUIPMENTGROUNDING

CONDUCTOR SIZE

SINGLE PHASE2-WIRE + GND.CONDUIT SIZE

SINGLE PHASE3-WIRE + GND.CONDUIT SIZE

SINGLE PHASE4-WIRE + GND.CONDUIT SIZE

15 12 AWG 12 AWG 3/4" 3/4" 3/4"

20 12 AWG 12 AWG 3/4" 3/4" 3/4"

25 10 AWG 3/4" 3/4" 3/4"

30 10 AWG 3/4" 3/4" 3/4"

35 8 AWG 3/4" 3/4" 3/4"

40 8 AWG 3/4" 3/4" 3/4"

45 6 AWG 3/4" 3/4"

50 6 AWG 3/4" 3/4"

60 4 AWG

70 4 AWG 10 AWG

80 3 AWG

90 2 AWG

100 1 AWG

1"

1-1/4" 1-1/2" 1-1/2"8 AWG

8 AWG

8 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

1"

1"

1" 1"

1"

1-1/4"

1-1/4"

1"

1"

1-1/4"

1-1/4"

1-1/4"

1-1/4"

* * =

* ** =

*****

CARDREADER

LIGHTSWITCH

DATA /TELEPHONE / TV

OUTLET

DUPLEXRECEPTACLE

4 PLEXRECEPTACLE

SCR NOTE:TYPICAL MOUNTING HEIGHTS UNLESSOTHERWISE NOTED.

3' -

8"

3' -

8"

1' -

6"

1' -

6"

1' -

6"

TYPICAL DEVICE MOUNTING HEIGHTS

RE

FE

R T

OR

OU

GH

-IN S

CH

ED

ULE

CL

FINISHEDFLOOR

WALL

DOUBLE GANG DEVICEBOX AND SINGLEGANG MUD RING

PULL STRING

LOCK NUT

SET SCREW TYPE EMTCONNECTOR

1" CONDUIT

UNSULATING BUSHING

SUSPENDED ACCESSIBLECEILING (TYP)

GYPSUM BOARD (TYP)

FACEPLATE

6"A

BO

VE

CE

ILIN

G

TIE PULL STRING END TOSTRUCTURE

STUB-OUT CONDUIT ABOVESUSPENDED CEILING

THE ELECTRICAL INSTALLATION SHALL CONFORM TO THE LATEST EDITION OF NFPA 70 (NEC), NFPA 780, ALL APPLICABLE LOCALLYADOPTED BUILDING, AND ENERGY CODES.

THE ELECTRICAL CONTRACTOR SHALL PRESERVE THE FIRE RATING OF ANY FIRE-RATED WALL, CEILING OR FLOOR BY PROVIDING AUL LISTED FIRE-RATED ASSEMBLY. COORDINATE FIRE-RATED WALL, CEILING, OR FLOOR ASSEMBLY LOCATIONS WITH THEARCHITECTURAL DRAWINGS.

ALL EQUIPMENT, DEVICES, AND LUMINAIRES SHALL BE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY ARE INSTALLED.EQUIPMENT MOUNTED OUTDOORS SHALL BE NEMA 3R. DEVICES MOUNTED IN DAMP OR WET LOCATIONS SHALL BEWEATHERPROOF. 120V RECEPTACLES RATED 15 OR 20 AMPS SHALL BE GFCI PROTECTED AND EQUIPPED WITH A “WHILE-IN-USE”COVER WHERE THEY ARE LOCATED IN DAMP OR WET LOCATIONS.

ALL LUGS, TERMINALS, ETC. IN ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LISTED FOR A MINIMUM OF 75 DEGREE CCONDUCTORS. TERMINATIONS LISTED FOR ONLY 60 DEGREE C CONDUCTORS ARE NOT PERMITTED.

CIRCUITS SERVING EMERGENCY LIGHTING EQUIPMENT SUCH AS EMERGENCY BATTERIES SHALL NOT SHARE A NEUTRAL (SHALL NOTBE PART OF A MULTIWIRE BRANCH CIRCUIT) WITH ANY OTHER CIRCUIT. PROVIDE A SEPARATE NEUTRAL FOR EVERY CIRCUIT THATSERVES EMERGENCY LIGHTING EQUIPMENT.

PROVIDE A DEDICATED NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR FOR EACH BRANCH CIRCUIT.

MINIMUM BRANCH CONDUCTOR SIZE SHALL BE #12 AWG AND MINIMUM CONDUIT SIZE SHALL BE ½ INCH. PROVIDE A GREENINSULATED EQUIPMENT GROUNDING CONDUCTOR IN WITH ALL CIRCUITS, SIZED IN ACCORDANCE WITH THE NEC; #12 AWGMINIMUM.

CONCEAL ALL CONDUITS AND CONDUCTORS IN WALLS, (BLOCK WALLS INCLUDED) AND ABOVE CEILINGS. PROVIDE A PULL STRINGIN ALL EMPTY CONDUITS.

LOCATION OF DISCONNECT SWITCHES ARE APPROXIMATE. ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION INFIELD. LOCATION SHALL BE FREE OF MECHANICAL PIPING AND DUCT WORK AND MEET ALL NEC REQUIREMENTS.

ALL RECEPTACLE COVER PLATES SHALL MATCH EXISTING COLOR, MATERIAL, AND CONFIGURATION.

ALL EMPTY CONDUITS SHALL BE PROVIDED WITH PULL STRING THROUGHOUT AND EXTENDING 12" BEYOND EACH END OF THECONDUIT.

COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITHIN ANY MILLWORK WITH MILLWORK VENDOR PRIOR TO ROUGH-IN.

COORDINATE THE CONNECTIONS OF ALL EQUIPMENT PROVIDED BY OTHERS WITH THE CONTRACTOR PROVIDING THE EQUIPMENTPRIOR TO ROUGH-IN. THIS INCLUDES, BUT IS NOT LIMITED TO, MECHANICAL EQUIPMENT, AUDIO/VISUAL EQUIPMENT ETC. THEELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE THE APPROPRIATE DISCONNECTING MEANS FOR, AND TO MAKE THE FINALCONNECTION TO, ANY HARDWIRED EQUIPMENT. THE ELECTRICAL CONTRACTOR IS ALSO RESPONSIBLE TO PROVIDE ANAPPROPRIATE CORD AND PLUG FOR ANY CORD-AND-PLUG CONNECTED EQUIPMENT THAT IS NOT EQUIPPED WITH AN INTEGRALCORD AND PLUG.

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

ELECTRICAL GENERAL NOTES

K.

L.

M.

VERIFY EXISTING CONDITIONS AND LOCATIONS IN FIELDPRIOR TO SUBMITTING PROPOSAL. FAILURE TO DO SO SHALLNOT RELIEVE THE CONTRACTOR FROM PERFORMING THEWORK REQUIRED UNDER THIS CONTRACT.

DISCONNECT AT THE SOURCE AND REMOVE EXISTINGELECTRICAL MATERIALS, EQUIPMENT, AND FIXTURES WHICHARE RENDERED OBSOLETE BY THE DEMOLITION,ALTERATIONS, AND ADDITIONS

WHERE EXISTING CONDUITS HAVE BEEN MADE OBSOLETE BYTHESE ALTERATIONS AND ADDITIONS AND IT IS IMPRACTICALTO REMOVE SAME, CONTRACTOR SHALL: a) CUT CONDUITSOFF AT SLAB OR WALL LINE. b) CAP ALL OBSOLETECONDUITS.

WHERE THE EXISTING WIRING AND CONDUIT SERVING ANYEXISTING ELECTRICAL EQUIPMENT IN AREAS OF THEEXISTING BUILDING NOT BEING ALTERED IS INTERFEREDWITH, CONTRACTOR SHALL REROUTE AND RECONNECT ALLSUCH CONDUIT AND WIRING.

OWNER SHALL BE GIVEN FIRST RIGHT OF REFUSAL OF ALLMATERIALS BEING REMOVED. ALL MATERIALS NOTACCEPTED BY THE OWNER THEN BECOME PROPERTY OF THECONTRACTOR AND MUST BE REMOVED FROM PREMESIS. IFOWNER ELECTS TO TAKE POSSESSION OF ANY MATERIALSBEING REMOVED, CONTRACTOR SHALL DELIVER MATERIALSTO OWNER IN SATISFACTORY CONDITION. VERIFY WHATMATERIALS, IF ANY, OWNER DESIRES TO KEEP PRIOR TOBEGINNING DEMOLITION.

WHEN WORKING IN AND AROUND THE EXISTING BUILDING,EXTREME CARE SHALL BE EXERCISED WITH REGARD TOPROTECTION OF THE EXISTING STRUCTURE AND ANY ITEMSWHICH ARE TO REMAIN. REPAIR, REPLACE, OR RESTORE TOTHE SATISFACTION OF THE ARCHITECT/ENGINEER ALLEXISTING WORK DAMAGED IN THE PERFORMANCE OFDEMOLITION AND/OR NEW WORK.

PATCHING OF ALL NEW AND EXISTING OPENINGS IN WALLS,CEILINGS, ROOF, AND FLOOR SURFACES DAMAGED ORCREATED BY DEMOLITION WORK SHALL MATCH EXISTINGADJACENT SURFACES AS TO THICKNESS, TEXTURES,MATERIAL, AND COLOR.

ALL PATCHING SHALL BE PERFORMED TO THE SATISFACTIONOF THE ARCHITECT/ENGINEER AND AT NO ADDITIONALCONTRACT COST.

REMOVE ALL SUPPORTING MEANS ASSOCIATED WITH ALLELECTRICAL EQUIPMENT AND FIXTURES THAT AREREMOVED.

ELECTRICAL FIXTURES AND EQUIPMENT THAT WILL BE RE-USED OR RE-INSTALLED SHALL BE CAREFULLY REMOVED ASNOT TO DAMAGE THE EQUIPMENT OR FIXTURE ANDPROTECTED FROM DAMAGE UNTIL READY FOR RE-INSTALLATION. THE CONTRACTOR SHALL BE RESPONSIBLEFOR THE REPLACEMENT COST OF ANY EQUIPMENT ORFIXTURES THAT BECOME DAMAGED PRIOR TO RE-INSTALLATION.

ELECTRICAL EQUIPMENT SHOWN DASHED SHALL BEREMOVED OR RELOCATED AS INDICATED.

ELECTRICAL CONTRACTOR SHALL CLEAN, RE-LAMP, ANDPROVIDE NEW BALLASTS FOR ALL EXISTING LIGHT FIXTURESTHAT ARE EXISTING OR WILL BE RELOCATED. ANY LIGHTFIXTURES WHICH DO NOT FUNCTION SHALL BE REPLACED TOMATCH THE EXISTING FIXTURE EXACTLY.

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

ELECTRICAL GENERAL DEMOLITION NOTES

ME

CH

AN

ICA

L /

ELE

CT

RIC

AL

EN

GIN

EE

RO

lsson

Ass

ocia

tes

60

1 P

Str

ee

t, S

uite

20

0L

inco

ln, N

E 6

850

84

02.4

74

.631

1

70

0 Q

St.

Lin

coln

, N

E 6

850

8T

: 4

02

47

6 7

33

1 F

: 4

02

47

6 8

34

1

SHA PROJECTNO.

DE

SIG

N E

NG

INE

ER

:

PR

OJE

CT

EN

GIN

EE

R:

DR

AW

N B

Y:

ISS

UE

D:

RE

VIS

ION

S:

Copyright SINCLAIR HILLE ARCHITECTSC

PR

OJE

CT

CO

NS

ULT

AN

TS

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

13 14

A

B

C

D

E

F

G

H

J

K

L

M

13 14

Ya

nk

ee

Rid

ge

Co

mm

erc

ial C

en

ter

Sy

lva

n L

ea

rnin

g C

en

ter

OA

PR

OJE

CT

#:

01

6-3

52

1

C:\Users\aohlman\Documents\ME_Sylvan TI_Central_63521_aohlman.rvt

1/1

2/2

01

7 9

:50

:23

AM

EL

EC

TR

ICA

L G

EN

ER

AL

INF

OR

MA

TIO

N

16073

GE001

01

/11

/20

17

AL

O

KS

C

KS

C

SCALE: NTS

TYPICAL PHONE/DATA ROUGH-IN DETAIL1

ELECTRICAL SHEET LISTSHEET

NUMBER SHEET NAME

GE001 ELECTRICAL GENERAL INFORMATION

E101 ELECTRICAL PLANS AND SCHEDULES

E201 ELECTRICAL SPECIFICATIONS

FB

FB

FB

FB

FB FB FB

FB

J

TC

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

FB

FB

FB

FB

FB FB FB

FB

SW+126"

SW+126"

7

S:8

S:11

EUH-1

S:16S:9

S:14

S:20

S:22

S:22,24

S:19

S:17,19

S

S:18

8

9

(E) EF

S:7

GFI+42"

GFI+42"

10S:21

S:13,15

11

S:1,3

12

OFFICE102

OFFICE103

WAITING100

INSTRUCTION101

CONFERENCE104

RESTROOM105

ELECTRICAL106

RESTROOM107

S:23,25

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

(ER)

B

A

AE

22

2

3

3

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

S

(E)

ER

A AE A

AA

A A

A A A

AAAE

S:12

1

1

2

3

3

EM

EM

EX

TO 'EF'

TO 'EF'

OFFICE102

OFFICE103

WAITING100

INSTRUCTION101

CONFERENCE104

RESTROOM105

ELECTRICAL106

RESTROOM107

a b a

aba

ba

ba

1

S:10

(ER) (ER)

(ER)

(ER)(ER)

(ER) (ER)

(E)(E)

4

5

6

(RE) (RE)

13

S

(E) PANEL

14

14

(RE)

(RE)

(RE)

(RE)

(RE)

(RE) (RE)

(RE) (RE)

(RE) (RE)

(RE) (RE)

EXISTING2000A/3

208Y/120V, 3PHMAIN

200/3

200/3

200/3

200/3

200/3

200/3

200/3

200/3

200/3

200/3

200/3

200/3EXISTING5000KVA

LES UTILITYTRANSFORMER

EXISTING SECONDARY CONDUCTORS

EXISTING TENANTFEEDERS

EXISTINGSQUARE D, NEMA 3R

EZ PAK METER CENTER

SYLVAN LEARNINGSUITE

EXISTINGPANEL 'S'

EXISTING600/3, 3PNEMA 3RENLOSEDCIRCUIT

BREAKEREXISTING

C.T.CABINET

EXISTINGMETER

SOCKET

EXISTING FEEDERDOLLAR TREE SERVICE

REFER TO ELECTRICAL GENERAL NOTES ON SHEET GE001.

REFER TO ELECTRICAL GENERAL DEMOLITION NOTES ONSHEET GE001.

REFER TO TYPICAL PHONE/DATA ROUGH-IN DETAIL ONSHEET GE001 FOR ALL PHONE, DATA, AND TV ROUGH-INS.

A.

B.

C.

GENERAL SHEET NOTES

REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS (RCP) FOR THE EXACT LOCATION OF ALL LIGHT FIXTURES. THE RCP SHALL TAKE PRECEDENCE OVER THELIGHTING PLAN IF THERE ARE ANY DISCREPANCIES. COORDINATE LIGHT FIXTURE LAYOUT WITH HVAC/DUCTWORK/DIFFUSERS.

COORDINATE THE MOUNTING HEIGHT OF ALL LIGHT FIXTURES WITH THE ARCHITECTURAL PLANS, ELEVATION OR ARCHITECT PRIOR TO ROUGH-IN.

PROVIDE ALL ACCESSORIES INCLUDING TRIM RINGS, STEMS, CANOPIES, CORDS, MOUNTING HARDWARE, RESTRAINTS, HURRICANE CLIPS, ETC., NECESSARY TO MOUNTTHE LIGHT FIXTURE IN A COMPLETE, PROPER, AND APPROVED METHOD.

PROVIDE A DISCONNECTING MEANS THAT OPENS ALL SUPPLY CONDUCTORS TO ANY BALLAST SERVING FLUORESCENT LIGHT FIXTURES THAT UTILIZE DOUBLE-ENDEDLAMPS AND THAT CAN BE SERVICED IN PLACE. THE DISCONNECTING MEANS SHALL ALSO OPEN THE NEUTRAL CONDUCTOR TO THE BALLAST WHEN THE LUMINAIRE ISSERVED BY A MULTI-WIRE BRANCH CIRCUIT.

SUPPORT ALL LUMINAIRES COMPLETELY INDEPENDENT OF ANY SUSPENDED CEILING.

ALL EXIT SIGNS SHALL BE EQUIPPED WITH INTEGRAL EMERGENCY BACKUP BATTERIES THAT PROVIDE A MINIMUM 90 MINUTES OF RUN TIME. CIRCUIT EXIT SIGNS TOUNSWITCHED EMERGENCY CIRCUIT UNLESS OTHERWISE INDICATED.

COORDINATE MOUNTING LOCATION, NUMBER OF FACES AND DIRECTIONAL ARROWS OF EXIT SIGNS AS REQUIRED TO MARK PATHS OF EGRESS TO THE SATISFACTIONOF THE AUTHORITY HAVING JURISDICTION.

EACH EMERGENCY FIXTURE SHALL BE PROVIDED WITH A FACTORY-INSTALLED OR FIELD-INSTALLED EMERGENCY BATTERY THAT PROVIDES A MINIMUM OF 90 MINUTESOF RUN TIME.

LOCATE OCCUPANCY SENSORS A MINIMUM OF 4-6 FEET FROM MECHANICAL DIFFUSER. COORDINATE LOCATION WITH OCCUPANCY SENSOR MANUFACTURER TOPROVIDE ADEQUATE COVERAGE.

WALL MOUNTED SENSOR SWITCHES SHALL BE SET TO MANUAL ON.

PROVIDE UNIVERSAL VOLTAGE BALLASTS FOR ALL FLUORESCENT FIXTURES. CONTRACTOR SHALL VERIFY THE AVAILABLE VOLTAGE WITH THE LIGHT FIXTURES PRIORTO ORDERING AND SUBMITTING SHOP DRAWINGS.

EMERGENCY BATTERIES FOR LINEAR FLUORESCENT AND/OR LONG COMPACT FLUORESCENT LAMPS SHALL BE RATED AT A MINIMUM OF 1400 LUMENS. THE EMERGENCYBATTERY SHALL POWER TWO LAMPS WHERE THE ASSOCIATED LIGHT FIXTURE IS EQUIPPED WITH MORE THAN ONE LAMP.

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

LIGHTING FIXTURE SCHEDULE GENERAL NOTES

ME

CH

AN

ICA

L /

ELE

CT

RIC

AL

EN

GIN

EE

RO

lsson

Ass

ocia

tes

60

1 P

Str

ee

t, S

uite

20

0L

inco

ln, N

E 6

850

84

02.4

74

.631

1

70

0 Q

St.

Lin

coln

, N

E 6

850

8T

: 4

02

47

6 7

33

1 F

: 4

02

47

6 8

34

1

SHA PROJECTNO.

DE

SIG

N E

NG

INE

ER

:

PR

OJE

CT

EN

GIN

EE

R:

DR

AW

N B

Y:

ISS

UE

D:

RE

VIS

ION

S:

Copyright SINCLAIR HILLE ARCHITECTSC

PR

OJE

CT

CO

NS

ULT

AN

TS

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

Ya

nk

ee

Rid

ge

Co

mm

erc

ial C

en

ter

Sy

lva

n L

ea

rnin

g C

en

ter

OA

PR

OJE

CT

#:

01

6-3

52

1

C:\Users\aohlman\Documents\ME_Sylvan TI_Central_63521_aohlman.rvt

1/1

2/2

01

7 9

:50

:22

AM

EL

EC

TR

ICA

L P

LA

NS

AN

DS

CH

ED

UL

ES

16073

E101

01

/11

/20

17

AL

O

KS

C

KS

C

SCALE: 1/8" = 1'-0"

POWER AND SYSTEMS PLAN1

SHEET KEYNOTES1 PROVIDE DUAL LEVEL WALL MOUNTED OCCUPANCY

SENSOR.

2 PROVIDE A LINE VOLTAGE CEILING MOUNTEDOCCUPANCY SENSOR AND WALL OVERRIDE SWITCH.

3 PROVIDE A LINE VOLTAGE WALL MOUNTED OCCUPANCYSENSOR.

4 EXISTING COMBINATION EXIT SIGN AND EMERGENCYLIGHT SHALL BE REMOVED AND REINSTALLED.

5 EIGHT LIGHT FIXTURE SWITCHES SHALL BE REMOVED.

6 REPLACE EXISTING SWITCH WITH OCCUPANCY SENSORAS SHOWN ON THE LIGHTING PLAN.

7 PROVIDE A JUNCTION BOX FOR POWER TO EXTERIORSIGNAGE. PROVIDE BRANCH CIRCUITING AND ON/OFFDISCONNECT SWITCH. COORDINATE FINAL JUNCTIONBOX LOCATION WITH THE LANDLORD AND TENANT PRIORTO INSTALLATION. CIRCUIT THROUGH TIME CLOCK INROOM ELECTRICAL ROOM 106.

8 PROVIDE 24 HOUR ELECTRICALLY OPERATED,MECHANICALLY HELD TIME CLOCK FOR SIGNAGE.

9 CONNECT EXHAUST FAN TO LOCAL SWITCH CIRCUITSERVING LIGHT FIXTURES.

10 PROVIDE 36”X36” SHEET OF PLYWOOD WITH TWO COATSOF FIRE RESISTANT PAINT FOR TELECOMMUNICATIONBACKBOARD. PROVIDE 1” CONDUIT STUBBED TOCOMMUNICATION BOARD FOR TELECOMMUNICATIONSERVICE.

11 EXISTING/RELOCATED WATER HEATER AND DISCONNECT.CONNECT TO EXISTING ELECTRICAL CIRCUIT.

12 NEW ELECTRIC WATER HEATER. PROVIDE NEW 60/2, N.F.DISCONNECT SWITCH AND MAKE FINAL CONNECTIONS.

13 EXISTING ELECTRIC WATER HEATER AND DISCONNECTSHALL BE REMOVED, RELOCATED AND RECONNECTED TOTHE EXISTING ELECTRICAL CIRCUIT.

14 REMOVE EXISTING LIGHTING TRACKS.

SCALE: 1/8" = 1'-0"

LIGHTING PLAN2SCALE: 1/8" = 1'-0"

ELECTRICAL DEMOLITION PLAN3

LIGHTING FIXTURE SCHEDULEFIXTURE

TYPE DESCRIPTION MANUFACTURER MODEL

LAMP APPARENT LOAD

VOLTAGE MOUNTING COMMENTSNO. WATTS TYPE CCT INPUT POWER

A RECESSED 2X4 VOLUMETRIC FLUORESCENT TROFFER LITHONIA 2RT8S-2 32 MVOLTGEB10IS L835HT8

2 32 W 32W T8 4100 K 64 VA 120 V RECESSED

AE RECESSED 2X4 VOLUMETRIC FLUORESCENT TROFFER,EMERGENCY BATTERY

LITHONIA 2RT8S 2 32 MVOLTGEB10IS L835HT8 EL

2 32 W 32W T8 4100 K 64 VA 120 V RECESSED

B SLIM SURFACE MOUNTED FLUORESCENT WRAP-AROUNDFIXTURE

LITHONIA CA 2 32 MVOLTGEB10IS

2 32 W 32W T8 4100 K 64 VA 120 V SURFACE

EM EMERGENCY LIGHT, BLACK LITHONIA ELM2 LED B 1 2 W LED 3200 K 2 VA 120 V CEILING

EX EMERGENCY EXIT LIGHT LITHONIA LHQM LED R 1 5 W LED 3200 K 5 VA 120 V CEILING

OTHER LOAD 11740 VA 100.00% 11740 VA

EXISTING LOAD

NON CONCURRENT HPL- PADLOCK ATTACHMENT TO LOCK C/B HANDLE IN OPEN POSITION

HEATING ONLY MAXIMUM DEMAND: 42.105 117 HLO - HANDLE LOCK ON DEVICE FOR CIRCUIT BREAKER

COOLING ONLY 15120 VA 100.00% 15120 VA CONNECTED LOAD: 40.388 112 GFPE - GROUND FAULT PROTECTION EQUIPMENT CIRCUIT BREAKER

KITCHEN GFCI - GROUND FAULT CIRCUIT INTERRUPTING TYPE CIRCUIT BREAKER

MOTORS 3000 VA 125.00% 3750 VA TOTAL PHASE C 12.01 100 BMS# - ROUTE CIRCUIT THROUGH BUILDING MANAGEMENT SYSTEM

RECEPTACLES 6660 VA 100.00% 6660 VA TOTAL PHASE B 13.42 114 CZ# - CONTROL ZONE NUMBER FOR REMOTE CONTROL

LIGHTING 3868 VA 125.00% 4835 VA TOTAL PHASE A 14.96 126 AFCI - ARC FAULT CIRCUIT INTERRUPTION TYPE CIRCUIT BREAKER

LOADCLASSIFICATIONS

CONNECTED(VA)

DEMANDFACTOR

DEMAND(VA) KVA AMPS NOTES:

-- SPACE ONLY -- -- 41 0 0 42 -- -- SPACE ONLY --

-- SPACE ONLY -- -- 39 0 0 40 -- -- SPACE ONLY --

-- SPACE ONLY -- -- 37 0 0 38 -- -- SPACE ONLY --

-- SPACE ONLY -- -- 35 0 0 36 -- -- SPACE ONLY --

-- SPACE ONLY -- -- 33 0 0 34 -- -- SPACE ONLY --

-- SPACE ONLY -- -- 31 0 0 32 -- -- SPACE ONLY --

-- SPACE ONLY -- -- 29 0 0 30 -- -- SPACE ONLY --

-- SPARE 20 A 1 27 0 0 28 -- -- SPACE ONLY --

-- -- -- -- 25 1500 540 26 1 20 A R - (E) FLOOR BOXES (E)

ELECTRIC UNIT HEATER - VESTIBULE... 20 A 2 23 1500 720 24 1 20 A R - CONF. ROOM (E)

R - PHONE BOARD, TIME CLOCK 20 A 1 21 360 720 22 1 20 A R - CONF. ROOM (E)

GFCI R - ELECTRIC WATER COOLER 20 A 1 19 800 720 20 1 20 A R - CONF. RM & CORRIDOR (E)

GFCI R - ELECTRIC WATER COOLER 20 A 1 17 800 1500 18 1 20 A R - COPY/PRINT (E)

-- -- -- -- 15 1800 900 16 1 20 A R - E. WALL INSTR. 101 & WAITING 100 (E)

WATER HEATER RESTROOM 107 35 A 2 13 1800 900 14 1 20 A R - W. WALL INSTR. 101 (E)

(E) R - SHOW WINDOW 20 A 1 11 360 1192 12 1 20 A L - OFFICES, WAITING., RR, ELEC RM (E)

(E) R - OFFICES 102, 103 20 A 1 9 1620 1176 10 1 20 A L - INSTRUCTION 101 (E)

(E) R - RESTROOMS 20 A 1 7 360 1500 8 1 20 A EXTERIOR SIGNAGE (E)

(E) R - (E) FLOOR BOXES 20 A 1 5 900 5040 6 -- -- -- --

-- -- -- -- 3 1800 5040 4 -- -- -- --

(E) WATER HEATER RESTROOM 105 35 A 2 1 1800 5040 2 3 50 A (E) ROOF TOP UNIT (E)

NOTE LOAD DESCRIPTION C/BCKT.NO.

A B CCKT.NO.

C/B LOAD DESCRIPTION NOTE

FED FROM METER CENTER AVAILABLE SHORT CKT.... NO. OF POLES 42

MCB OR MLO MCB AIC RATING MOUNTING RECESSED

VOLTAGE 120/208 Wye PHASE BUS RATING 200A LOCATION ELECTRICAL 106

PANEL S (EXISTING)

SCALE: NONE

EXISTING RISER DIAGRAM4(E) - EXISTING CIRCUIT BREAKER

SECTION 260519 - WIRE

ALL WIRE SHALL HAVE COPPER CONDUCTORS, WITH U.L. LABEL, AND 600 VOLT INSULATION. ALL WIRE SHALL BE RUN IN CONDUIT. SERVICE ENTRANCECABLE SHALL BE TYPE USE, THWN OR XHHW WITH STRANDED CONDUCTORS. ALL FEEDER AND BRANCH CIRCUIT WIRE #8 AWG AND LARGER SHALL BETYPE THWN OR XHHW, BOTH WITH STRANDED CONDUCTORS. ALL WIRE #10 AWG AND SMALLER SHALL BE TYPE THWN (WET OR DAMP LOCATIONS, OR INCONDUIT BELOW GRADE OR SLAB) OR THHN (DRY LOCATIONS ONLY AND ABOVE GRADE), BOTH WITH SOLID CONDUCTORS. WIRE WITHIN FLUORESCENTFIXTURE CHANNELS SHALL BE TYPE THHN. ALL BRANCH CIRCUIT WIRING SHALL BE NOT SMALLER THAN #12 AWG WIRE. IF NO WIRE SIZE IS INDICATEDON THE PLANS FOR A BRANCH CIRCUIT, PROVIDE #12AWG WIRE AND A 20A CIRCUIT BREAKER. CONTROL WIRING SHALL HAVE 600V INSULATION AND BEOF THE PROPER TYPE, SIZE AND NUMBER AS REQUIRED TO ACCOMPLISHED SPECIFIED FUNCTION. NO MORE THAN 6 RECEPTACLES OR 16 AMPS OFLOAD PER CIRCUIT. TYPE NM SHEATHED CABLE IS ACCEPTABLE TO BE INSTALLED WITHIN THE APARTMENT UNITS ONLY. CONTRACTOR SHALL ADJUSTWIRE SIZES FOR VOLTAGE DROP.

WIRING INSTALLATION

ALL WIRING SHALL BE INSTALLED IN APPROVED RACEWAY AND ENCLOSURES.

SUPPORT ALL WIRE AND CABLES IN VERTICAL INSTALLATIONS AS REQUIRED BY CODE BY INSTALLING CABLE SUPPORTERS OR PLUG-TYPE CONDUITRISER SUPPORTS.

ALL WIRE AND CABLE IN CONDUIT SHALL BE CONTINUOUS WITHOUT TAPS OR SPLICES. ALL SPLICES OR TAPS SHALL OCCUR IN APPROVED BOXES ANDENCLOSURES AND SHALL BE KEPT TO THE MINIMUM REQUIRED, AND SHALL BE MADE UP WITH APPROVED SOLDERLESS CONNECTORS. ALL SPLICES,TAPS, AND JOINTS SHALL BE INSULATED AS REQUIRED BY CODE.

ALL MATERIALS USED TO TERMINATE, SPLICE OR TAP CONDUCTORS SHALL BE DESIGNED FOR, PROPERLY SIZED FOR, AND U.L. LISTED FOR THE SPECIFICAPPLICATION AND CONDUCTORS INVOLVED, AND SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS,USING THE MANUFACTURER'S RECOMMENDED TOOLS.

WHERE WIRE IS INDICATED TO BE INSTALLED, BUT THE CONNECTION IS INDICATED "FUTURE" OR "BY OTHERS", CONTRACTOR SHALL LEAVE A MINIMUM OF3 FEET OF "PIGTAIL" AT THE BOX, TAPE THE ENDS OF THE CONDUCTORS, AND COVER THE BOX.

CONDUCTORS SHALL HAVE INSULATION OF THE PROPER COLOR TO MATCH NEC COLOR CODE SYSTEM AND IN THE TABLE BELOW. IN LARGER WIRESIZES WHERE PROPERLY COLORED INSULATION IS NOT AVAILABLE, THE CONTRACTOR SHALL USE VINYL PLASTIC ELECTRICAL TAPE OF THEAPPROPRIATE COLOR AROUND EACH CABLE AT ALL TERMINATION POINTS, JUNCTION AND PULL BOXES.

SYSTEM VOLTAGE, CONDUCTOR TYPE, COLOR:208Y/120

BLACK PHASE A RED PHASE B BLUE PHASE C WHITE NEUTRAL GREEN EQUIPMENT GROUND

ALL TERMINAL BLOCKS AND WIRE TERMINALS FOR CONTROL WIRING SHALL BE PROPERLY NUMBERED FOR IDENTIFICATION WITH VINYL STICK-ONMARKERS OR EQUIVALENT.

ALL RECEPTACLE AND NON-LIGHTING EQUIPMENT BRANCH CIRCUITS SHALL HAVE AN EQUIPMENT GROUND CONDUCTOR INSTALLED IN THE BRANCHCIRCUIT RACEWAY, SIZED IN ACCORDANCE WITH NEC TABLE 250.122.

VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 2%.

SECTION 260526 - GROUNDING

THE ELECTRICAL SERVICE, ALL TRANSFORMERS, CONDUCTORS, CONDUITS, MOTOR FRAMES, AND SIMILAR CONDUCTING SURFACES IN THIS CONTRACTWHICH REQUIRE GROUNDING SHALL BE PERMANENTLY AND EFFECTIVELY GROUNDED BY THIS CONTRACTOR IN A THOROUGH AND EFFICIENT MANNER INCONFORMANCE TO THE NATIONAL ELECTRICAL CODE. ALL CIRCUITS SHALL HAVE SEPARATE GREEN GROUND CONDUCTOR ROUTED WITH PHASECONDUCTORS.

SECTION 260533 - RACEWAYS

GENERAL REQUIREMENTS

ALL CONDUIT SHALL BE RUN CONCEALED EXCEPT WHERE OTHERWISE NOTED. ALL CONDUIT RUN UNDERGROUND SHALL BE RIGID STEEL OR PVCSCHEDULE 40. ALL CONDUIT EXPOSED TO WEATHER, OR OTHER HAZARDOUS CONDITIONS SHALL BE RIGID STEEL. ALL OTHER CONDUIT MAY BETHIN-WALL EMT WHERE APPROVED BY LOCAL CODE.

FINAL CONNECTION TO EACH MOTOR AND TRANSFORMER, AND TO ANY DEVICE WHICH WOULD OTHERWISE TRANSMIT MOTION, VIBRATION OR NOISE,SHALL BE IN FLEXIBLE METAL CONDUIT. WHERE FLEXIBLE METAL CONDUIT IS EXPOSED TO LIQUIDS, VAPORS OR SUNLIGHT, LIQUID-TIGHT FLEXIBLEMETAL CONDUIT SHALL BE USED. ALL FLEXIBLE METAL CONDUIT SHALL BE PROVIDED WITH AN INSULATED GROUND WIRE.

CONDUIT INSTALLATION

ALL CONDUIT RUNS SHOWN ARE DIAGRAMMATIC, EXACT LOCATIONS SHALL BE DETERMINED IN THE FIELD.

CONDUIT SHALL BE INSTALLED CONCEALED ABOVE SUSPENDED CEILINGS OR CONCEALED IN WALL OR IN OR BENEATH FLOORS WHEREVER POSSIBLE.RUN PARALLEL TO BUILDING

CONDUIT SHALL BE INSTALLED TO REQUIREMENTS OF STRUCTURE AND TO REQUIREMENTS OF ALL OTHER WORK ON THE PROJECT. CONDUIT SHALL BEINSTALLED TO CLEAR ALL OPENINGS, DEPRESSIONS, PIPES, DUCTS, REINFORCING STEEL, AND SIMILAR ITEMS. CONDUIT SET IN FORMS FOR CONCRETESTRUCTURE SHALL BE INSTALLED IN SUCH A MANNER THAT INSTALLATION WILL NOT AFFECT THE STRENGTH OF THE STRUCTURE. EXCEPT WHEREAPPROVED IN WRITING BY THE ARCHITECT, NO CONDUIT SHALL BE RUN IN A SLAB ON GRADE. CONDUIT SHALL BE LOCATED IN GRANULAR FILL BELOWSLABS-ON GRADE.

CONDUITS SHALL BE INSTALLED CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS, BOXES AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OFBENDS AND NOT MORE THAN THE EQUIVALENT OF FOUR 90 BENDS BETWEEN CONNECTIONS. BENDS SHALL BE SMOOTH AND EVEN AND SHALL BE MADEWITHOUT FLATTENING CONDUIT OR FLAKING ENAMEL. RADIUS OF BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN THECORRESPONDING TRADE ELBOW. LONG RADIUS ELBOWS SHALL BE USED WHERE NECESSARY.

CONDUITS SHALL BE SECURELY FASTENED IN PLACE WITH APPROVED STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. SINGLE CONDUITS FORFEEDERS SHALL BE HUNG WITH MALLEABLE SPLIT RING HANGERS WITH ROD AND TURNBUCKLE SUSPENSION FROM INSERTS SPACED NOT OVER 10 FEETAPART IN CONSTRUCTION ABOVE. GROUPS OF HORIZONTAL FEEDER CONDUITS SHALL BE CLAMPED TO UNISTRUT STEEL CHANNELS AND SUSPENDEDFROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. VERTICAL FEEDER CONDUITS SHALL BE SECURELY CLAMPED TOSTRUCTURAL STEEL MEMBERS ATTACHED TO STRUCTURE. CABLE CLAMPS SHALL BE INSTALLED FOR SUPPORT OF VERTICAL FEEDERS WHEREREQUIRED. CONDUIT SUPPORTS SHALL BE ADDED WITHIN 12" AT ONE END OF ALL BENDS. CONDUIT SHALL NOT BE SUPPORTED FROM SUSPENDEDCEILING COMPONENTS.

CONDUIT ENDS SHALL BE REAMED BEFORE INSTALLATION AND ALL CONDUIT SHALL BE THOROUGHLY CLEANED BEFORE INSTALLATION AND KEPT CLEANAFTER INSTALLATION. OPENINGS AND BOXES SHALL BE PLUGGED OR COVERED AS REQUIRED TO KEEP CONDUIT CLEAN DURING CONSTRUCTION ANDALL CONDUIT SHALL BE FISHED CLEAR OF OBSTRUCTIONS BEFORE THE PULLING OF WIRES. ALL CONDUIT SHALL BE OF AMPLE SIZE FOR PULLING OFWIRE AND SHALL NOT BE SMALLER THAN CODE REQUIREMENTS AND NOT LESS THAN 3/4" IN SIZE.

ALL ELECTRICAL WORK SHALL BE PROTECTED AGAINST DAMAGE DURING CONSTRUCTION. ANY WORK DAMAGED OR MOVED OUT OF LINE AFTERROUGHING-IN SHALL BE REPAIRED TO MET ENGINEER'S APPROVAL WITHOUT ADDITIONAL COST TO THE OWNER.

CONDUIT TERMINATIONS AT PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL EQUIPMENT AND JUNCTION BOXES SHALL BE ALIGNED AND INSTALLEDTRUE AND PLUMB.

INSTALL APPROVED EXPANSION FITTINGS WHERE CONDUIT OR EMT PASSES THROUGH EXPANSION JOINTS.

INSTALL A PULL WIRE IN EACH EMPTY CONDUIT WHICH IS LEFT BY THE CONTRACTOR FOR INSTALLATION OF WIRES OR CABLES BY OTHERS.

MAKE ALL JOINTS AND CONNECTIONS IN A MANNER WHICH WILL INSURE MECHANICAL STRENGTH AND ELECTRICAL CONTINUITY.

THRU-WIRING OF LIGHT FIXTURES IS NOT PERMITTED.

BUSHINGS AND LOCKNUTS

WHERE CONDUITS ENTER BOXES, THEY SHALL BE RIGIDLY CLAMPED TO THE BOX BY A BUSHING ON THE INSIDE AND A LOCKNUT ON THE OUTSIDE, ANDCONDUIT SHALL ENTER THE BOX SQUARELY. BUSHINGS AND LOCKNUTS SHALL BE MADE OF GALVANIZED MALLEABLE IRON AND SHALL HAVE SHARP,CLEAN-CUT THREADS. WHERE THIN-WALL CONDUIT ENTERS BOX, PROVIDE APPROVED E.M.T. CONNECTORS. USE INSULATED GROUNDING BUSHINGSWHEREVER CONNECTION IS SUBJECT TO VIBRATION OR MOISTURE.

SECTION 260553 - EQUIPMENT IDENTIFICATION

THIS CONTRACTOR SHALL FURNISH AND INSTALL EQUIPMENT IDENTIFICATION NAMEPLATES ON ALL PANELBOARDS, SWITCHES, STARTERS, ETC.,INCLUDING SWITCHES IN DISTRIBUTION PANELS. NAMEPLATES SHALL BE ENGRAVED PHENOLIC PLASTIC AND SHALL BE FIRMLY ATTACHED TO THEEQUIPMENT WITH SELF-TAPPING, STAINLESS STEEL SCREWS OR STAINLESS STEEL MACHINE SCREWS WITH NUTS AN FLAT AND LOCK WASHERS.NAMEPLATES SHALL CLEARLY IDENTIFY EACH ITEM AND WHAT IT CONTROLS.

DIVISION 26 - ELECTRICAL SPECIFICATIONS

SECTION 260100 - GENERAL PROVISIONS

GENERAL REQUIREMENTS

ALL REQUIREMENTS UNDER DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS SHALL BE A PART OF THISSECTION. EACH CONTRACTOR SHALL BE RESPONSIBLE TO BECOME THOROUGHLY FAMILIAR WITH ALL ITS CONTENTS AS TO REQUIREMENTS WHICHAFFECT THIS DIVISION OR SECTION. THE WORK REQUIRED UNDER THIS SECTION INCLUDES ALL MATERIAL, EQUIPMENT, APPLIANCES, AND LABORREQUIRED TO COMPLETE THE ENTIRE SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS, OR REASONABLY INFERRED TO BE NECESSARYTO FACILITATE EACH SYSTEMS FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT SPECIFIED.

INSPECTION OF SITE

THE CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDERWHICH THE WORK IS TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRACOMPENSATION OVER AND ABOVE THE CONTRACT PRICE.

MATERIAL AND WORKMANSHIP

ALL MATERIAL AND APPARATUS SHALL BE NEW AND IN FIRST CLASS CONDITION. ALL MATERIAL AND APPARATUS SHALL HAVE MARKINGS OR ANAMEPLATE IDENTIFYING THE MANUFACTURER AND PROVIDING SUFFICIENT REFERENCE TO ESTABLISH QUALITY, SIZE AND CAPACITY. ALLWORKMANSHIP SHALL BE OF THE FINEST POSSIBLE BY EXPERIENCED MECHANICS OF THE PROPER TRADE. IN GENERAL, ALL MATERIALS ANDEQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTABLE.ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND EQUIPMENT REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORKSHALL BE FURNISHED BY THIS CONTRACTOR. MATERIAL AND EQUIPMENT SHALL BE STORED AND MAINTAINED IN CLEAN CONDITION, AND PROTECTEDFROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE. ALL ELECTRICAL MATERIALS USED IN THIS WORK SHALL BE APPROVED BY THE UNDERWRITER'SLABORATORIES AND SHALL BEAR THEIR LABEL OF APPROVAL.

COORDINATION

THE CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER CONTRACTORS AND SUBCONTRACTORS SO THAT VARIOUS COMPONENTS OF THEELECTRICAL SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE AND WILL ALLOW PROPER SERVICE ACCESS TO ALLEQUIPMENT. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL, STRUCTURAL AND MECHANICAL DRAWINGS AND TO RELEVANT EQUIPMENTDRAWINGS TO DETERMINE THE EXTENT OF CLEAR SPACES. THE CONTRACTOR SHALL MAKE ALL OFFSETS REQUIRED TO CLEAR EQUIPMENT, BEAMS ANDOTHER STRUCTURAL MEMBERS; AND TO FACILITATE CONCEALING CONDUIT IN THE MANNER ANTICIPATED IN THE DESIGN. THE CONTRACTOR SHALLPROVIDE MATERIALS WITH TRIM WHICH WILL FIT PROPERLY THE TYPES OF CEILING, WALL, OR FLOOR FINISHES ACTUALLY INSTALLED.

SUBMITTALS

SUBMIT ONE ELECTRONIC VERSION OF SHOP DRAWINGS AND PRODUCT DATA ON ALL ELECTRICAL EQUIPMENT TO BE PROVIDED BY THE CONTRACTOR.

TITLE EACH DRAWING WITH PROJECT NAME AND NUMBER; IDENTIFY EACH ELEMENT OF DRAWINGS BY REFERENCE TO SHEET NUMBER AND DETAIL,SCHEDULE OR ROOM NUMBER OF CONTRACT DOCUMENTS.

SEQUENTIALLY NUMBER SUBMITTALS ACCORDING THEIR SPECIFICATION SECTION NUMBER. REVISED SUBMITTALS SHOULD INCLUDE ORIGINAL NUMBERAND A SEQUENTIAL ALPHABETIC SUFFIX. CONTRACTOR SHALL ALLOW TWO WEEKS FOR ENGINEERING REVIEW.

CONTRACTOR AND SUPPLIER SHALL REVIEW AND STAMP AND SIGN SUBMITTALS PRIOR TO TRANSMITTAL; DETERMINE AND VERIFY FIELDMEASUREMENTS, FIELD CONSTRUCTION CRITERIA, MANUFACTURERS CATALOG NUMBERS AND CONFORMANCE OF SUBMITTAL WITH REQUIREMENTS OFCONTRACT DOCUMENTS. IDENTIFY IN WRITING AT TIME OF SUBMITTAL OF ANY DEVIATIONS FROM REQUIREMENTS OF CONTRACT DOCUMENTS.

MARK DIMENSIONS AND VALUES IN UNITS TO MATCH THOSE SPECIFIED.

MARK ANY FEATURES/OPTIONS BEING PROVIDED. DELETE OR PUT A LINE THROUGH FEATURES/OPTIONS THAT ARE NOT BEING PROVIDED.

DO NOT FABRICATE OR ORDER PRODUCTS OR BEGIN WORK THAT REQUIRES SUBMITTALS UNTIL APPROVAL OF SUBMITTAL.

APPROVAL OF EQUIPMENT DOES NOT CONSTRUE APPROVAL OF EQUIPMENT, COMPONENTS, ETC. THAT NO INFORMATION IS FURNISHED TO SHOWCOMPLIANCE WITH CONTRACT DOCUMENTS.

CONTRACTOR SHALL PAY A SHOP DRAWING REVIEW FEE OF $100.00, TO THE ENGINEER, FOR EACH SHOP DRAWING REVIEW AFTER TWO REVIEWS THATARE MARKED "RETURNED FOR CORRECTIONS" BY THE ENGINEER.

SUBSTITUTIONS

THE ENGINEER SHALL BE THE SOLE AND FINAL JUDGE AS TO THE SUITABILITY OF ITEMS SUBSTITUTED FOR THOSE SPECIFIED. ALTERNATEEQUIVALENT SUBSTITUTIONS SHALL BE REVIEWED BY THE ENGINEER DURING THE SUBMITTAL OF SHOP DRAWINGS. PRIOR APPROVAL REQUESTS FORSUBSTITUTIONS WILL NOT BE REVIEWED.

THE ENTIRE COST OF ALL CHANGES OF ANY TYPE DUE TO SUBSTITUTIONS FOR MATERIALS SPECIFIED SHALL BE BORNE BY THE CONTRACTOR AT NOEXTRA COST TO THE OWNER AND SHALL REIMBURSE OTHER TRADES OF ADDITIONAL COST DUE TO SUBSTITUTION.

DOCUMENT EACH REQUEST WITH COMPLETE DATA SUBSTANTIATING COMPLIANCE OF PROPOSED SUBSTITUTION WITH CONTRACT DOCUMENTS.

REQUEST CONSTITUTES A REPRESENTATION THAT CONTRACTOR:1. HAS INVESTIGATED PROPOSED PRODUCT AND DETERMINED THAT IT MEETS OR EXCEEDS, IN ALL RESPECTS, SPECIFIED PRODUCT.2. WILL PROVIDE THE SAME WARRANTY FOR SUBSTITUTION AS FOR SPECIFIED PRODUCT.3. WILL COORDINATE INSTALLATION AND MAKE OTHER CHANGES THAT MAY BE REQUIRED FOR WORK TO BE COMPLETE IN ALL RESPECTS.4. WAIVES CLAIMS FOR ADDITIONAL COSTS OR TIME EXTENSION THAT MAY SUBSEQUENTLY BECOME APPARENT.5. WILL REIMBURSE OWNER FOR REVIEW OR REDESIGN SERVICES ASSOCIATED WITH RE-APPROVAL BY AUTHORITIES.SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN THEY ARE INDICATED OR IMPLIED ON SHOP DRAWING OR PRODUCT DATA SUBMITTALS WITHOUTSEPARATE WRITTEN REQUEST, OR WHEN ACCEPTANCE WILL REQUIRE SUBSTANTIAL REVISION OF CONTRACT DOCUMENTS.

DIMENSIONS AND LAYOUTS

THE DRAWINGS ARE SCHEMATIC IN NATURE, BUT SHOW THE VARIOUS COMPONENTS OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TOINDICATE HOW THEY ARE TO BE INTEGRATED WITH OTHER PARTS OF THE BUILDING. FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO SCALEDIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB MEASUREMENTS, BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY REVIEWING ALLCONTRACT DOCUMENTS. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS WHICH COULD HAVE BEEN AVOIDED BY PROPER CHECKING ANDINSPECTION.

ORDINANCES AND CODES

CONTRACTOR'S PERFORMANCE, WORKMANSHIP AND MATERIALS SHALL COMPLY WITH NATIONAL FIRE PROTECTION ASSOCIATION CODES, STATE ANDLOCAL BUILDING CODES, AND/OR ALL OTHER APPLICABLE CODES AND ORDINANCES. CONTRACTOR SHALL COMPLY WITH RULES AND REGULATIONS OFPUBLIC UTILITIES AND MUNICIPAL DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS,LICENSES, FEES AND INSPECTIONS REQUIRED FOR THE WORK UNDER THIS CONTRACT UNLESS OTHERWISE SPECIFIED. CONTRACTOR SHALL BE HELDRESPONSIBLE FOR ANY VIOLATION OF THE LAW. CONTRACTOR SHALL MAINTAIN ALL NECESSARY SIGNAL LIGHTS AND GUARDS FOR THE SAFETY OF THEPUBLIC.

ADJUSTING, ALIGNING AND TESTING

ALL ELECTRICAL EQUIPMENT ON THIS PROJECT FURNISHED UNDER THIS DIVISION AND ALL ELECTRICAL EQUIPMENT FURNISHED BY OTHERS SHALL BEADJUSTED, ALIGNED AND TESTED FOR PROPER OPERATION BY THE ELECTRICAL CONTRACTOR. COMPLETE WIRING SYSTEMS SHALL BE FREE FROMSHORT CIRCUITS. ALL MOTORS SHALL BE VERIFIED FOR PROPER ROTATION.

THE CONTRACTOR SHALL MAINTAIN ON THE PROJECT PREMISES THE FOLLOWING AT ALL TIMES: A TRUE RMS READING VOLTMETER, A TRUE RMSREADING AMMETER, AND A MEGGER INSULATION RESISTANCE TESTER. THE CONTRACTOR SHALL PROVIDE TEST DATA RATINGS AS REQUESTED OR ASREQUIRED.

CUTTING AND PATCHING

THIS CONTRACTOR SHALL DO ALL CUTTING OF WALLS, FLOORS, CEILINGS, ETC. AS REQUIRED TO INSTALL WORK UNDER THIS SECTION. CONTRACTORSHALL OBTAIN PERMISSION OF THE ARCHITECT BEFORE DOING ANY CUTTING. ALL HOLES SHALL BE CUT AS SMALL AS POSSIBLE. CONTRACTOR SHALLPATCH WALLS, FLOORS, ETC. AS REQUIRED BY WORK UNDER THIS SECTION. ALL PATCHING SHALL BE THOROUGHLY FIRST CLASS AND SHALL MATCHTHE ORIGINAL MATERIAL AND CONSTRUCTION.

COORDINATE WITHOUT DELAY ALL ROUGHING-IN WITH GENERAL CONSTRUCTION. ALL CONDUIT ROUGH-IN SHALL BE CONCEALED EXCEPT INUNFINISHED AREAS AND WHERE OTHERWISE SHOWN.

GUARANTEE

GUARANTEE AGAINST DEFECTIVE WORKMANSHIP AND MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF WRITTEN FINAL ACCEPTANCE.GUARANTEE SHALL INCLUDE MATERIAL TO BE REPLACED AND ALL LABOR REQUIRED.

FIRESTOPPING OF FLOOR AND WALL PENETRATIONS

THIS CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH FIRE RATED FLOOR AND WALL ASSEMBLIES IN ACCORDANCE WITH NFPA CODES AND ULWALL CONSTRUCTION TYPES. THE SEALING SYSTEM MUST BE CAPABLE OF PASSING A THREE HOUR TEST, PER ASTM E-814 (UL 1479). PENETRATIONSEALING SYSTEM SHALL BE, AT A MINIMUM, 3M BRAND 7904 (CP-25 CAULK, OR 303 PUTTY), OR APPROVED EQUAL, AND SHALL BE INSTALLED INACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.

FLASHING AND PITCH POCKETS

FLASH AND COUNTERFLASH ALL OPENINGS THROUGH ROOF, AND/OR PROVIDE PITCH POCKETS AS REQUIRED. ALL ROOF PENETRATIONS SHALL BE LEAKTIGHT AT THE TERMINATION OF THE WORK.

SECTION 262416 - PANELBOARDS

THE ELECTRICAL PANEL AND DISTRIBUTION ARE EXISTING. PROVIDE NEW CIRCUIT BREAKERS THAT ARE COMPATIBLE WITH AND OF THE SAMEMANUFACTURER OF THE EXISTING ELECTRICAL PANEL.

MOLDED CASE CIRCUIT BREAKERS: NEMA AB 1, BOLT-ON TYPE THERMAL MAGNETIC TRIP CIRCUIT BREAKERS, WITH COMMON TRIP HANDLE FOR ALLPOLES, LISTED AS TYPE SWD FOR LIGHTING CIRCUITS, TYPE HACR FOR AIR CONDITIONING EQUIPMENT CIRCUITS, CLASS A GROUND FAULTINTERRUPTER CIRCUIT BREAKERS WHERE SCHEDULED. DO NOT USE TANDEM CIRCUIT BREAKERS.

INSTALLATION

PROVIDE FILLER PLATES FOR UNUSED SPACES IN PANELBOARDS.

PROVIDE TYPED CIRCUIT DIRECTORY FOR EACH BRANCH CIRCUIT PANELBOARD. REVISE DIRECTORY TO REFLECT CIRCUITING CHANGES REQUIRED TOBALANCE PHASE LOADS. CIRCUIT DIRECTORY SHALL BE SUBMITTED TO ENGINEER FOR REVIEW PRIOR TO FINAL PHASE BALANCING.

PROVIDE ENGRAVED PLASTIC NAMEPLATES.

GROUND AND BOND PANELBOARD ENCLOSURE ACCORDING TO NEC.

MEASURE STEADY STATE LOAD CURRENTS AT EACH PANELBOARD FEEDER; REARRANGE CIRCUITS IN THE PANELBOARD TO BALANCE THE PHASELOADS TO WITHIN 20 PERCENT OF EACH OTHER. MAINTAIN PROPER PHASING FOR MULTI-WIRE BRANCH CIRCUITS. SUBMIT MEASURED INITIAL LOADCURRENT FOR EACH PHASE TO ENGINEER FOR REVIEW PRIOR TO COMPLETING FINAL BALANCING FOR EACH PANELBOARD.

SECTION 262726 - WIRING DEVICES

FURNISH AND INSTALL THE FOLLOWING OUTLETS AND SWITCHES WHERE SHOWN OR REQUIRED. MINOR CHANGES RELATIVE TO THE LOCATION OFELECTRICAL EQUIPMENT MAY BE MADE BY THIS CONTRACTOR TO COMPLY WITH STRUCTURAL AND BUILDING REQUIREMENTS AS DETERMINED IN THECOURSE OF CONSTRUCTION. ALL OUTLETS AND SWITCHES MUST BE OF THE SAME MANUFACTURER AND NOT MIXED ON THE PROJECT. COLOR OFTOGGLES AND RECEPTACLES SHALL BE GREY. ALL EXTERIOR RECEPTACLES SHALL BE GFCI TYPE AND PROVIDED WITH WEATHERPROOF WHILE-IN-USECOVER.

DUPLEX RECEPTACLE: PASS & SEYMOUR #5362SINGLE POLE SWITCH: PASS & SEYMOUR #20AC1THREE-WAY SWITCH: PASS & SEYMOUR #20AC3GFCI DUPLEX RECEPTACLE: PASS & SEYMOUR #2091

EQUIVALENT HUBBELL, LEVITON AND BRYANT, WILL BE ACCEPTABLE. OTHER DEVICES SHOWN ON THE PLANS BUT NOT CALLED OUT ABOVE SHALL BEOF THE SAME CONSTRUCTION QUALITY AS DEFINED BY THE MODEL NUMBERS SHOWN.

SWITCH AND OUTLET COVER PLATES

ALL SWITCH AND OUTLET PLATES SHALL BE P&S SMOOTH PLASTIC. SWITCH PLATES IN UNFINISHED ROOMS AND SPACES SHALL BE STAMPED STEELPLATES, CADMIUM PLATED. GROUPS OF SWITCHES SHALL BE UNDER ONE GANG-PLATE, USUALLY MOUNTED HORIZONTALLY; WHERE REQUIRED BYDETAILS, VERTICAL MOUNTING SHALL BE USED INSTEAD. PLATES SHALL BE SET PLUMB, PARALLEL, AND SHALL FINISH FLUSH WITH THE WALL.WEATHERPROOF COVER PLATES SHALL BE CAST ALUMINUM LISTED AND LABELED EXTRA DUTY WITH PVC GASKETING AND RATED FOR "WHILE-IN-USE".

LOCATIONS OF OUTLETS, SWITCHES AND OTHER WIRING DEVICES

OUTLETS MUST BE CENTERED WITH REGARD TO PANELING, FURRING, AND TRIM. ANY OUTLET WHICH IS IMPROPERLY LOCATED MUST BE CORRECTEDAT THE CONTRACTOR"S EXPENSE. OUTLETS MUST BE SET PLUMB OR HORIZONTAL AND SHALL EXTEND TO THE FINISHED SURFACE OF THE WALL,CEILING OR FLOOR AS THE CASE MAY BE WITHOUT PROJECTING BEYOND SAME. RECEPTACLES, SWITCHES, AND OTHER WIRING DEVICES SHOWN ONWOOD TRIM, CASES OR OTHER FIXTURES SHALL BE INSTALLED SYMMETRICALLY ON SUCH TRIM OR FIXTURE AND WHERE NECESSARY, SHALL BE SETWITH THE LONG DIMENSION OF THE PLATE HORIZONTAL, OR SHALL BE GANGED IN TANDEM.

MOUNTING HEIGHTS TO CENTER OF BOX ABOVE FINISHED FLOOR SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED.

GENERAL FLUSH SWITCHES, MANUAL STATIONS 48"GENERAL CONVENIENCE RECEPTACLES 18"PANELBOARDS, TO TOP 72"TELEPHONE PANELS, TO TOP 72"SAFETY SWITCHES 54"MOTOR CONTROLLERS 54"

SECTION 262816 - DISCONNECT SWITCHES

CONTRACTOR SHALL FURNISH AND INSTALL SQUARE D, SIEMENS, GENERAL ELECTRIC OR CUTLER HAMMER FUSED OR NON-FUSED (AS NOTED ORREQUIRED) NEMA HEAVY DUTY EXTERNALLY OPERATED SAFETY SWITCHES WHERE NOT FURNISHED WITH THE STARTING EQUIPMENT, AND AT ALLOTHER POINTS REQUIRED BY CODE. FUSE HOLDERS SHALL HAVE CLASS R REJECTION FEATURE. CONSTRUCTION SHALL BE OF A NEMA DESIGNSUITABLE FOR THE ENVIRONMENT INSTALLED IN.

FUSES

EACH CIRCUIT AND SET OF FUSE CLIPS THROUGHOUT THE JOB SHALL BE EQUIPPED WITH BUSSMAN OR EQUIVALENT SHAWMUT FUSES, SIZE AND TYPEAS REQUIRED OR INDICATED. ALL FUSES LARGER THAN 600 AMPS, SHALL BE UL CLASS L, SIMILAR TO TYPE KRP-C. BUSSMAN LOW PEAK OREQUIVALENT. FUSES USED TO PROTECT MOTORS SHALL BE UL CLASS RK5, BUSSMAN FUSETRON OR EQUIVALENT. ALL FUSIBLE SWITCHESTHROUGHOUT THE PROJECT SHALL HAVE FUSE HOLDERS WITH CLASS R REJECTION FEATURE. ALL FUSED DEVICES SHALL BE LABELED AS TO TYPEAND SIZE OF FUSE REQUIRED.

SPARE FUSES

FURNISH THREE SPARE FUSES OF EACH SIZE AND TYPE USED ON THE PROJECT (EXCEPT MAIN SWITCH FUSES), NEATLY CONTAINED IN A PROPERLYLABELED CABINET.

.

SECTION 265100 - LIGHT FIXTURES, LAMPS AND BALLASTS

LIGHT FIXTURE LOCATIONS

LIGHT FIXTURES SHOWN ON THE ELECTRICAL DRAWINGS REPRESENT GENERAL ARRANGEMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS FORMORE EXACT LOCATIONS. COORDINATE LOCATION WITH ALL OTHER TRADES BEFORE INSTALLATION TO AVOID CONFLICTS. LIGHT FIXTURESLOCATIONS IN MECHANICAL ROOMS SHALL BE COORDINATED WITH FINAL INSTALLED PIPING AND DUCTWORK LAYOUTS.

LIGHT FIXTURES

PROVIDE LIGHT FIXTURES AS SCHEDULED ON DRAWINGS. THIS SHALL INCLUDE ALL LAMPS, MATERIAL AND LABOR TO SECURELY HANG FIXTURES,CLEAN THEM AND MAKE THEM COMPLETELY READY FOR USE. ALL LIGHT FIXTURES SHALL INCLUDE ALL NECESSARY ACCESSORIES REQUIRED. LIGHTFIXTURE MODELS SCHEDULED ON THE DRAWINGS ARE TO SHOW THE MANUFACTURER, GRADE AND STYLE OF FIXTURES REQUIRED ONLY. PROVIDE ALLHANGERS, SUPPORTS, AND MISCELLANEOUS HARDWARE REQUIRED TO INSTALL LIGHT FIXTURES. PROVIDE PROPER TRIM TO FIT EACH CEILINGCONDITION ACTUALLY ENCOUNTERED. PROVIDE ADDITIONAL TIE WIRES CONNECTED TO STRUCTURE TO CONFORM TO UB 47-18 SEISMICREQUIREMENTS WHERE REQUIRED.

THROUGH WIRING OF FIXTURES IS NOT PERMITTED. EACH FIXTURE MUST BE CONNECTED BY A WHIP TO A JUNCTION BOX. THE WHIP SHALL BE MIN. #14CU IN 1/2"C. AND OF SUFFICIENT LENGTH TO ALLOW THE FIXTURE TO BE RELOCATED WITHIN A 6' RADIUS.

LAMPS

LAMPS FOR ALL LIGHTING FIXTURES SHALL BE PROVIDED AND INSTALLED BY THIS CONTRACTOR. PROVIDE LAMPS INDICATED ON THE DRAWINGS, OR IFNOT INDICATED, AS RECOMMENDED BY THE FIXTURE MANUFACTURER. IN ALL CASES LAMPS SHALL BE COMPATIBLE WITH SPECIFIED FIXTURE. LAMPSSHALL BE MANUFACTURED BY GENERAL ELECTRIC, OSRAM/SYLVANIA, PHILLIPS, OR VENTURE.

RE-LAMP ALL EXISTING LIGHTING FIXTURES.

ALL FLUORESCENT LAMPS SHALL BE 4100 K, UNLESS NOTED OR DIRECTED OTHERWISE.

BALLASTS

ALL FLUORESCENT BALLASTS: SHALL BE THERMALLY PROTECTED AGAINST OVERHEATING; SHALL BE ETL-CBM, CLASS P TO MEET ALL REQUIREMENTSOF SECTION 410-73 (E) OF THE NEC AS A MINIMUM; SHALL COMPLY WITH THE NATIONAL BALLAST ENERGY LAW; SHALL HAVE A MINIMUM 90% POWERFACTOR; SOUND LEVELS SHALL NOT EXCEED CLASS A AMBIENT NOISE LEVELS; AND SHALL BE LOW HEAT TYPE.

INDOOR FLUORESCENT BALLASTS; SHALL BE PROGRAM START; SHALL BE ELECTRONIC TYPE SUITABLE FOR OPERATION OF T8 LAMPS; SHALL HAVE ATOTAL HARMONIC DISTORTION LESS THAN 10%; SHALL HAVE A FREQUENCY OF OPERATION OF 20 KHZ OR GREATER AND OPERATE WITH NO VISIBLEFLICKER; SHALL WITHSTAND LINE TRANSIENTS AS DEFINED IN ANSI/IEEE C62.41, CATEGORY A; AND SHALL BE ADVANCE REL/VEL SERIES OR EQUAL OFMAGNETEK, MOTOROLA OR OSRAM.

ME

CH

AN

ICA

L /

ELE

CT

RIC

AL

EN

GIN

EE

RO

lsson

Ass

ocia

tes

60

1 P

Str

ee

t, S

uite

20

0L

inco

ln, N

E 6

850

84

02.4

74

.631

1

70

0 Q

St.

Lin

coln

, N

E 6

850

8T

: 4

02

47

6 7

33

1 F

: 4

02

47

6 8

34

1

SHA PROJECTNO.

DE

SIG

N E

NG

INE

ER

:

PR

OJE

CT

EN

GIN

EE

R:

DR

AW

N B

Y:

ISS

UE

D:

RE

VIS

ION

S:

Copyright SINCLAIR HILLE ARCHITECTSC

PR

OJE

CT

CO

NS

ULT

AN

TS

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

J

K

L

M

13 14

A

B

C

D

E

F

G

H

J

K

L

M

13 14

Ya

nk

ee

Rid

ge

Co

mm

erc

ial C

en

ter

Sy

lva

n L

ea

rnin

g C

en

ter

OA

PR

OJE

CT

#:

01

6-3

52

1

C:\Users\aohlman\Documents\ME_Sylvan TI_Central_63521_aohlman.rvt

1/1

2/2

01

7 9

:50

:23

AM

EL

EC

TR

ICA

L S

PE

CIF

ICA

TIO

NS

16073

E201

01

/11

/20

17

AL

O

KS

C

KS

C