17
Journal of Green Engineering (JGE) Volume-10, Issue-1, January 2020 Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand 1 S.Christi, 2 A.Arunraj, 3 V.Venkatesan, 4 R.Logaraja 1 Assistant Professor, Faculty of Civil Engineering, St. Joseph College of Engg., Chennai, India. E-mail: [email protected] 2 Assistant Professor, Faculty of Civil Engineering, Easwari Engg College., Chennai, India.E-mail: [email protected] 3 Assistant Professor, Faculty of Civil Engineering, University College of Engg., Ariyalur, India E-mail: [email protected] 4 Assistant Professor ,Faculty of Civil Engineering, Sethu Institute of Technology, Kariapatti, India. E-mail: [email protected] Abstract The study investigates about the suitability and sustainability of usage of Manufacturing Sand (M-Sand) of ferrocement concrete beams with including and excluding of reinforcement. To achieve this, investigation consists of beams with the dimension of 300mm x 150mm x 1000mm with stable precast formwork of thickness of about 25mm are made. The reinforced concrete beams of the above mentioned dimension are casted for conventional concrete specimens. A welded wire mesh of single layer is used as reinforcement in the beams. After casting, the beams are undergone with curing for 28 days and testing was conducted under two point loading concept. On comparison of the test results it is found that, the ferrocement overlay beam possess more strength, better resistance against cracking and good energy absorption. Hence, ferrocement overlay beam satisfy the higher serviceability limits. Keywords: Sustainable Ferrocement, M-Sand, Reinforcement, RC beam, Resistance. Journal of Green Engineering, Vol. 10_1, 144160. Alpha Publishers This is an Open Access publication. © 2020 the Author(s). All rights reserved

Study on Behavior of Sustainable Ferrocement Overlay Beam ... · the structural behaviour of ferrocement is the matrix. Selection of materials for the matrix and the placing and also

  • Upload
    others

  • View
    26

  • Download
    0

Embed Size (px)

Citation preview

Journal of Green Engineering (JGE)

Volume-10, Issue-1, January 2020

Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand

1S.Christi,

2A.Arunraj,

3V.Venkatesan,

4R.Logaraja

1Assistant Professor, Faculty of Civil Engineering, St. Joseph College of Engg.,

Chennai, India. E-mail: [email protected] 2Assistant Professor, Faculty of Civil Engineering, Easwari Engg College., Chennai,

India.E-mail: [email protected] 3Assistant Professor, Faculty of Civil Engineering, University College of Engg.,

Ariyalur, India E-mail: [email protected] 4Assistant Professor ,Faculty of Civil Engineering, Sethu Institute of Technology,

Kariapatti, India. E-mail: [email protected]

Abstract

The study investigates about the suitability and sustainability of usage of

Manufacturing Sand (M-Sand) of ferrocement concrete beams with including

and excluding of reinforcement. To achieve this, investigation consists of

beams with the dimension of 300mm x 150mm x 1000mm with stable

precast formwork of thickness of about 25mm are made. The reinforced

concrete beams of the above mentioned dimension are casted for

conventional concrete specimens. A welded wire mesh of single layer is used

as reinforcement in the beams. After casting, the beams are undergone with

curing for 28 days and testing was conducted under two point loading

concept. On comparison of the test results it is found that, the ferrocement

overlay beam possess more strength, better resistance against cracking and

good energy absorption. Hence, ferrocement overlay beam satisfy the higher

serviceability limits.

Keywords: Sustainable Ferrocement, M-Sand, Reinforcement, RC beam,

Resistance.

Journal of Green Engineering, Vol. 10_1, 144–160. Alpha Publishers

This is an Open Access publication. © 2020 the Author(s). All rights reserved

145 S.Christi

et al

1 Introduction

Now days, Civil Engineering is moving through with an advanced

development techniques and construction methods. Since increase in

demand of construction materials and heavy weight of conventional

concrete this affects the development. Trying to overcome these causes M-

sand is used instead of River Sand and Ferrocement concept is applied to

conventional concrete. This present work focus on the ferrocement beam

jacketing by using M-Sand[1].

2 Literature Study

Ferrocement is a blended component consists of cement mortar that

impart tensile strength and steel fibers in the pattern of wire mesh as

reinforcement which deformability to the material. Because of the

distribution of small mesh reinforcement over entire volume of the mortar,

very high resistance against cracking is obtained, besides improvement in

many engineering properties [1]. View to enhance the shear and flexural

capacity to restrain the cracking and deflection in the concrete structure

strengthening was recommended. For that reason various types of materials

have been used from early age. Implementation of repair works with

ferrocement in the early 1980’s contributes more on the repair of lining

membranes in the liquid storage, pipeline structures, etc.

Study made with the usage of ferrocement for repair works and

strengthening also conducted. Some of the applications of ferrocement are

the Tanks, Containers, Silos, Floors and Roofs, Pipes & Sewer lines etc. [3]

Ferrocement is a product in which layers of metallic or non metallic weld

mesh are used in reinforcing the structural members. Appropriate steel /

weld mesh size is selected such that adequate bonding is achieved between

matrix and reinforcement. Durability of the concrete is increased through

ferrocement. The use of mesh in the concrete helps in increasing a tensile

strength to a modest level. The ferrocement as a stiff material which can

hold the heavy concrete helps in places of form work.

This work is aims to analyze the strength of the ferrocement jacketing

with comparative study of river sand and M-sand. The amount of deflection

that could be taken in the beam until outer crack also tested.

3 Material Requirements

The constituent materials of ferrocement for this work are wire mesh

reinforcement, smaller size aggregates, cement mortar and admixtures.

Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand 146

3.1 Matrix

The constituents in the ferrocement include the binder particles as

Portland cement, fine aggregate as M-sand and water. Admixtures may be

suitably used based on the purpose of the product. The Quality of the Fine

aggregate passes through American Standards ASTM No. 8 sieve (Indian

Standards IS size of 2.36 mm) sieve. The governing material in controlling

the structural behaviour of ferrocement is the matrix. Selection of materials

for the matrix and the placing and also the curing should be done with

caution.

3.2 Cement

Cement factors are normally higher in ferrocement than in reinforced

concrete. The cement confirmed with ASTM C 150, ASTM C 595, or with

an equivalent standard of IS codes. The quality of cement should be

maintained as prescribed by codal provisions. [5]

The most commonly used cement type is designated as Type I in ASTM

C 150. Type II cement generates less heat during hydration and is also

moderately resistant to sulfates. Type III is rapid-hardening cement which

acquires early strength more rapidly than Type I cement. Type IV is low-

heat cement used for mass concrete and is seldom considered for

ferrocement. Type V is sulfate-resisting cement used in structures exposed

to sulfate.

3.3 Ground Granulated Blast Furnace Slag(GGBS)

In GGBS, main constituents like oxides of magnesium, calcium, aluminium

and silicon di-oxide. It is produced by the process of quenching of molten

iron slag then dried and powedered into a fines to obtain a glassy granular

product. The combination of ordinary Portland cement and/or other

pozzolanic materials with the GGBS is used to make durable concrete

structures. While GGBS used obviously there will be reduction of hazard due

to reaction of alkali-silica gives resistance to access of chloride. . Physical

properties of GGBS have been presented in Table 1 and also shown in Fig 1.

[2]

147 S.Christi et al

(a) (b)

Fig 1 GGBS (a) 50 Kg bag (b) powder form

Table 1 Physical Properties of GGBS

The aggregates are the key constituents of the concrete which influences

the strength, density and other properties. In this work Local aggregates

comprising of 20 mm and 12mm coarse aggregates and fine aggregates

were used in saturated surface dry state, were used. The coarse aggregates

and the fine aggregate was crushed granite type aggregate of size less than

5mm commonly called as M-sand (manufactured sand) were used. Different

types of aggregates have obtained locally for experimental work is

discussed below.

3.4.1 Fine aggregate (M-Sand)

M-sand is used as fine aggregate in the experimental work and is

obtained from the local suppliers near Sriperumbudur in Chennai which is

shown in Fig 2. The physical properties of fine aggregate (M-Sand) have

been done and presented in Table 2.

S.No Physical properties Test Result

1 Specific gravity 2.85

2 Physical form Powder

3 Size (Micron) 0.3

4 Colour White

5 Blaine fineness 400 m2 /kg

6 Density 2800 kg/m3

Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand 148

Fig 2 M-Sand as fine aggregate

3.4.2 Coarse aggregates

In this study, coarse aggregates of size between 12 mm and 20 mm

conforming to specifications as given in IS: 383- 1970 is used. Specific

Gravity (SG) of aggregates is found through Pycnometer test. Sieve analysis

has been done to find the fineness modulus (FM) of aggregate. The physical

properties of the coarse aggregate of size 12mm and 20mm have been

displayed in Table 2 respectively [2].

Table 2 Physical properties of aggregate

S.No Items Fine Aggregate Coarse Aggregate

1 Type Crushed stone (M-

Sand)

Crushed

stone Crushed stone

2 Particle Size

(Maximum) 4.75 mm 12mm 20 mm

3 SG-Specific gravity 2.65 2.67 2.71

4 FM-Fineness modulus 3.33 6.80 7.68

3.5 Water

Clean Portable water (pH 6.5 – 7) free from organic and inorganic

substances was used in the preparation of ferrocement concrete.

149 S.Christi et al

3.6 Wire Mesh Reinforcement

The objective of providing wire mesh as reinforcement is to impart

tensile strength to concrete and resist against cracking. It also supports in

holding the ferrocement concrete together in wet state. The commercially

available weld meshes are as shown in Fig 3. In this study, 2.5mm thick steel

rods welded into square mesh of size 25mm x 25mm made were used.

Fig. 3 Different shapes of Wire Mesh

4. Experimental Investigation

The main aim of this work is to study the flexural strength of concrete

beams with ferrocement jacketing. The experimental program consists of

casting and testing of three RCC beam of size 150mm × 300mm ×

1000mm. The aim of this work was done by the following tasks,

Specimen 1 - Control beam.

Specimen 2 - Beam jacketing with river sand. (Core M- sand).

Specimen 3 - Beam jacketing with M- Sand. (Core M-sand)

4.1 Mix Design

Using the concept of ferrocement, Beam jacketing with river sand and

M-sand Specimens at the size of 1000mm x 150 mm x 300mm are casted. A

control beam is also made at the size of 1000 mm x 150mm x 300mm and

all three beams is to be tested and all the values are to be compared with

each other to check flexural strength and deflection [2] [5].

Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand 150

• For Control Beam ( M25 -mix ratio 1:1.5:3 )

1. Cement = 20.45 kg.

2. M-Sand = 30.68 kg.

3. Aggregate (12mm) = 33.75 kg.

4. Aggregate (20mm) = 27.61 kg.

5. Reinforcement at both Tensions& Compression zone = 4nos of 12mmΦ

6. Stirrups = 6nos of 6mm Φ150mm c/c

7. Water cement ratio = 0.45

• Beam Jacketing with River Sand

Ferrocement (mix ratio 1:2)

1. Cement = 9.34kg

2. GGBS = 2.33kg

3. River sand = 23.33kg

4. Water cement ratio = 0 .4

Core material (M25 - mix ratio 1:1.5:3)

1. Cement = 12.5kg

2. M-sand = 18.75kg

3. Aggregate (12 mm) = 20.5kg

4. Aggregate (20 mm) = 17kg

5. Reinforcement = 2nos of 12mmΦ (Tension Zone)

6. Water cement ratio = 0.45

• Beam Jacketing with M-Sand Ferrocement (mix ratio1:2)

1. Cement = 9.34kg

2. GGBS = 2.33kg

3. M-Sand = 23.33kg

4. Water cement ratio = 0.4

Core material (M25-mix ratio 1:1.5:3)

1. Cement = 12.5kg

2. M-sand = 18.75kg

3. Aggregate (12 mm) = 20.5kg

4. Aggregate (20 mm) = 17kg

5. Reinforcement = 2nos of 12mmΦ (Tension Zone)

6. Water cement ratio = 0.45

151 S.Christi

et al

4.2 Preparation of the Mortar

To prepare a ferrocement beam, mortar required for jacketing the G.I

Mesh is done. Cement and GGBS are taken in the ratio of 0.8:0.2. This

binder is then mixed with fine aggregates on the ratio of 1:2. Water content

as per the W/C ratio is added to this dry ingredients of concrete to get a

perfect mortar which is shown in Fig 4.

Fig.4 Preparation of ferrocement mortar

4.3 Casting of the beam

A G.I mesh of size 900 mm x 165mm is placed inside the mould and the

cement mortar mix is placed. This set up kept without disturbance for 24

hours. Then, the beam is casted by placing the M25 concrete inside the wire

mesh. The beam is then allowed for curing after the demoulding. Mould and

placing of wire mesh for Beam jacketing is shown in Fig 5and Casted

Sample is shown in Fig 6.

(a)

Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand 152

(b)

Fig 5 a) Mould for casting of beam b) Mesh gauge

Fig 6 Casted sample of beam

4.4 Curing of the beam

The beam is cured by wrapping the beam with wet gunny bags. When

the gunny bag dries, it wetted again by pouring the water. This is generally

done once in a day. Curing of the beam is shown in Fig 7.

Fig 7 Curing process of the casted Beam

153 S.Christi

et al

The above Manufacturing Process is used for casting the all three

Specimens. Mixing of materials and Quantity is changed according to the

specimen needed.

4.5 Tests on Ferrocement Beam Jacketing

Flexural strength test is carried out to find the flexural strength of

specimen. In this study beam samples were casted and cured in direct sun

light for 28 days. After curing all the three Specimens 1000mm ×150mm

×300mm were tested by using Universal Testing Machine UTM with a

capacity of 1000 kN. [6]

The beam is dividing into three parts with 150 mm on both ends and

700mm in the center and it is marked. The beam is further divided into three

parts in the middle portion to 233.33mm (700/3) and it is marked. Then the

beam is placed on the supports. This beam is tested in two point method.

The beam is placed with the outer length of 150mm at the both ends on the

supports. Then the load is applied on the center of the beam with two

supports on the top. [8]

As the load increases, the deflection is noted for every 10 kN. The

flexural strength of the concrete is then found by 1.5wδ/bd2. The UTM is

shown in Fig 8.

Fig 8 Universal Testing Machine

Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand 154

5 Results and Discussions

The results obtained from the experimental study on flexural strength of

ferrocement beam jacketing using river sand and M-sand has been discussed

as follows.

Flexural behavior of the beam is noted for every 10 KN load and

deflection of the beam also compared. From the test, it was known that for

the control beam crack is formed when the load comes to 196 kN and the

corresponding flexural strength and deflection at that point is 8.6 N/mm2 and

3.86 mm respectively. The variation of flexural strength and Deflection

along with load for control beam is shown in Fig 9. The graph was plotted

for the better understanding of result interpretation. From the graph it was

clearly observed that, corresponding to the load flexural strength and

deflection was gradually increased. At the point of 196kN the member loss

its elasticity and started to failure. The failure of beam is shown in Fig 10[8]

[12].

Fig 9. Effect of variation in flexural strength and deflection with load for control

beam (specimen -1)

0.2

7

0.4

2

0.5

1

0.6

0

0.7

1

0.8

6

1.0

0

1.1

0

1.2

3

1.4

8

1.5

8

1.8

0

2.1

2

2.5

0

2.6

4

2.8

8

3.0

0

3.2

0

3.6

3

3.8

6

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

11.0

12.0

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

5.00

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

Fle

xtu

ral

Str

en

gth

N/m

m2

De

fle

ctio

n i

n m

m

Load in kN

Loas Vs Deflection & Flextural Strength on Control Beam

Flextural Strength Deflection

155 S.Christi et al

Fig 10. Failure of the specimen

Similarly other two specimens were tested and the results are discussed

for the flexural behavior of ferrocement beam using River sand and M-sand.

It was clearly observed that ferrocement beam with River Sand were loss its

elasticity and started to failure at the load point171.4kN and the

corresponding flexural strength was 8.9 N/mm2 and its deflection was 3.92

mm. For the better observation, results are plotted in a graph to know the

effect of variation of flexural strength and variation of Deflection with

loading using River sand is shown in Fig 11.

Fig 11. Effect of variation in flexural strength and deflection with load using River

sand

Similarly Specimen 3 (M-sand overlaying) was tested and results were

discussed and graphs were plotted for the effect of variation and deflection

0.3

5

0.5

6

0.7

5

0.9

0

1.0

0

1.0

9

1.2

3

1.5

2

1.7

3

1.9

1

2.1

3

2.3

9

2.8

3

3.1

9

3.4

8

3.8

9

3.9

2

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

11.0

12.0

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

5.00

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170

Fle

xtu

ral

Str

en

gth

N/m

m2

De

fle

ctio

n i

n m

m

Load in kN

Loas Vs Deflection & Flextural Strength on River Sand

Flextural Strength Deflection

Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand 156

with increase in loading is shown in Fig 12. It was observed that the

Specimen 3 obtain failure at the loading point 201 kN and the corresponding

flexural strength and deflection were10.4N/mm2 and 4.7 mm respectively.

Fig 12. Effect of variation in flexural strength and deflection with load using M-sand

While comparing the flexural strength of all the three types of specimen,

it was clearly observed that the M-sand jacketing specimen gives higher

strength when compared to other two specimens. Comparison of flexural

strength is shown in Fig 12 and Comparison of Deflection was shown in Fig

13. In the deflection chart which shows that M sand jacketing specimen

withstand large load upto 200kN and undergoes acceptable deflection. [11]

Fig13 Comparison of flexural strength

0.1

7

0.3

0

0.4

1

0.5

0

0.6

1

0.7

6

1.0

0

1.1

5

1.3

2

1.4

8

1.6

5

1.9

2

2.1

2

2.3

4

2.5

8

2.8

4

3.1

5

3.6

0

4.0

8

4.7

0

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

11.0

12.0

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

5.00

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

Fle

xtu

ral

Str

en

gth

N/m

m2

De

fle

ctio

n i

n m

m

Load in kN

Loas Vs Deflection & Flextural Strength on M-Sand

Flextural Strength Deflection

0.5

1

1.6

2.1

2.6

3.1

3.6

4.1

4.7

5.2

5.7

6.2

6.7

7.3

7.8

8.3

8.9

0.5

1

1.6

2.1

2.6

3.1

3.6

4.1

4.7

5.2

5.7

6.2

6.7

7.3

7.8

8.3

8.8

9.3

9.9

10.4

0.4

0.9

1.3

1.7

2.22.4

2.73

3.3

3.7

4.2

4.75

5.3

5.9

6.3

6.7

7.3

7.9

8.6

00.5

11.5

22.5

33.5

44.5

55.5

66.5

77.5

88.5

99.510

10.511

11.512

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

De

fle

ctio

n i

n m

m

Load in kN

Loas Vs Flextural Strength

River Sand M-sand Control Beam

157 S.Christi et al

Fig14 Comparison of Deflection

6 Conclusions

GGBS based ferrocement jacketing can be produced using technology

and equipment used for the manufacturing of conventional concrete. Using

jacketing in concrete helps to increasing the strength of the beam or column

and it used effectively in repairing structures, increasing the strength of the

deflected structures. From the test, it was known that for the control beam

crack is formed when the load comes to 196 kN and the corresponding

flexural strength is 8.6N/mm2 and deflection at that point 3.86mm

respectively and it is compared with other specimens, while comparing it

was clearly observed that ferrocement beam with River Sand were loss its

elasticity and started to failure at the load point 171.4kN and the

corresponding flexural strength was 8.9 N/mm2 and its deflection was

3.92mm but the ferrocement beam with M-sand were increases its elasticity

and started to failure at the loading point 201 kN and the corresponding

flexural strength and deflection were 10.4N/mm2

and 4.7 mm respectively.

[12]

The strength of the ferrocement jacketed beam with m-sand is high

when compared to that of ferrocement beam with river sand and control

beam which helps in increasing economic status of the structure. It is alkali

resistance when compare to other concrete and the GBS based ferrocement

keeps on increasing the strength of the beam from the day of 28 till 10 to 12

years.

0.35

0.56

0.750.9

11.09

1.23

1.52

1.73

1.91

2.13

2.39

2.83

3.19

3.48

3.89 3.92

0.170.3

0.410.5

0.610.76

11.15

1.321.48

1.65

1.92

2.12

2.34

2.58

2.84

3.15

3.6

4.08

4.7

0.270.42

0.510.6

0.710.86

11.1

1.23

1.481.58

1.8

2.12

2.52.64

2.883

3.2

3.63

3.86

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

De

fle

ctio

n i

n m

m

Load in kN

Loas Vs Deflection

River Sand M-sand Control Beam

Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand 158

References

[1] M. Afsarudin, M.F Hoque,., “Ferrocement as permanent formwork for

Reinforced concrete beams”, B.sc. Engineering Thesis, Department of

Civil Engineering, BUET, Dhaka, December 1998.

[2] ACI Committee 549-1R-88 and 1R-93: Guide for the Design,

Construction, and Repair of Ferrocement, ACI 549-1R-88 and 1R-93,

Manual of Concrete Practice, American Concrete Institute, Farmington

Hills, Michigan, 27 pages,1988 and 1993.

[3] M.S.Mathews, J.Sudhakumar ,P.Jayasree “Durability Studies On

Ferrocement”, Journal of Ferrocement, Vol.23, No.1, 1991.

[4] P.J. Walker “Moment –Curvature Relations for Ferrocement Beams”,

Journal of Ferrocement, Vol.25, No. 4,pp. 347-359, 1995,

[5] ACI Committee 549-R97: State-of-the-Art Report on Ferrocement, ACI

549-R97, Manual of Concrete Practice, American Concrete Institute,

Farmington Hills, Michigan, 26 pages,1997.

[6] S .Wang, A.E Naaman, V.C Li,. "Bending response of hybrid Ferro

cement plates with meshes and fibers",Journal of Ferrocement, Vol.34,

No.1, pp.275-288,2004.

[7] M.J. Shannag T.B. Ziyyad,"Flexural response of Ferro cement with

fibrous cementitious matrices",Construction and Building Materials,

Vol.21, no.6,pp.1198-1205,2007.

[8] S.Elavenil, V.Chandrasekar, “Analysis of Reinforced Concrete Beams

Strengthened with Ferrocement”, International Journal of Applied

Engineering Research, Vol.2,no. 3, pp. 431-440, 2007.

[9] J.H.L Bong, E Ahmed,” Study the Structural Behaviour of Ferrocement

Beam”, UNIMAS e-Journal of Civil Engineering,Vol. 1.no.2, 2010

[10] Divekar, B.N,”Revolutionary Ideas and Innovative Structures in

Ferrocement”, Proceedings of the National Conference on Ferrocement

(FS 2011), 2011.

[11] Y.B.I Shaheen, N.M. Soliman, A.M Hafiz,” Structural Behaviour of

Ferrocement channels beams”, Concrete Research Letters, Vol.4,no.3,

pp.621-638,2013.

[12]J.Thivya, A.Aarthi “Comparative Analysis of River Sand, M-Sand and

Quarry Sand”, International Research Journal of Engineering and

Technology ,vol.06,no.05,pp.923-927,2019.

159 S.Christi

et al

Biographies

S. Christi is a civil engineer graduate from University College of

Engineering, Ariyalur and obtain her post-graduate from AMS Engg College,

Namakkal. She is currently doing her doctoral degree at Annamalai

University, Chidambaram. She is presently working as Assistant professor in

St. Joseph College of engineering, Sriperumbudur. She is a Lifetime Member

in IAENG and IASE. She has been pursuing teaching for over three years.

She has been involved in research in the areas of concrete technology,

concrete structures and non-destructive testing.

A.Arunraj is a civil engineer graduate from K.S.R College of Engineering,

namakkal and obtain his post-graduate from AMS Engineering College,

Namakkal. He is currently working as an Assistant Professor, Department of

Civil Engineering, SRM Easwari Engg College, Ramapuram, Chennai. His

area of specialisation are concrete technology, concrete structures. He has 4

years of teaching experience. Published 02 International papers in scopus

indexed journal, 05 paper presented in national Conferences, and 01 paper

presented in International Conferences.

Study on Behavior of Sustainable Ferrocement Overlay Beam using M-Sand 160

Dr. Venkatesan.V was born in Irur Village on 03 June 1982 in Perambalur

District, Tamilnadu, India. He holds a Doctoral Degree in Hydrology and

Water Resources by the Anna University and is presently working as

Assistant Professor in the Department of Civil Engineering at University

College of Engineering Ariyalur (A Constituent College of Anna University

Chennai) since 2009. He has more than twelve years of teaching and research

experience. His area of specialisation are Remote sensing and GIS in

hydrology and Water resources applications. The Current research interst are

soft computing techniques in various applications of Water resources,

Irrigation Water Allocation, Studies on Repair of Concrete Elements and

Fiber Reinforced Concrete, Water Quality, Environmental Chemistry etc.

R.Logaraja He is a civil engineering graduate from NPR college of

engineering dindigul and obtain his post graduate from PSR engineering

college, sivakasi. He is currently working as an assistant professor in sethu

institute of technology, Madurai. His area of specialization are structural

dynamics and Earthquake engineering, special concrete and concrete

structure. He has published 8 international and 2 national journal. He has

received students scientist award from Tamilnadu science city, chennai