16
BALCONY BALCONY SBS V2.0 system system 316 Stainless Steel Modular Balcony System

Strudyna Balcony System

Embed Size (px)

DESCRIPTION

Strudyna Balcony System (SBS) was developed for use in both Residential and Commercial areas. Continue to promote maximum transparency, a departure from traditional paneled or solid balustrade which can restrict views and the movement of air. Made with 316 stainless steel components are incredibly strong & corrosion resistant; the system is also very easy to install and maintain.

Citation preview

Page 1: Strudyna Balcony System

BALCONYBALCONY

SBS V2.0

systemsystem

316 Stainless Steel Modular Balcony System

Page 2: Strudyna Balcony System

Plan view

page

Assembly parts for Balcony system A for 1 set

BALCONYBALCONYsystemsystem

2

A

Balcony system A 3D Model

www. strudyna.com

Sketch elevation front viewront vieew

NO. Name Code Size

Stanchion base

Stanchion post type A (Middle)

BC1B-1008

BC1P-MD90

Stanchion post type B (End)

for 1 set

3 PCS

1 PCS

2 PCSBC2P-EN90

51mm*90mm*85mm

40mm*9mm*874mm

40mm*9mm*874mm

Stanchion angle 8 PCSBC3H-0038 38mm*77mm*40mm

EM6 Deco stud 16 PCS2960-3630 3mm M6*30mm

Cable 1x19 8 PCSCX19-0003-1597 3mm*1597mm

Flat bar handrail type A1 1 PCSBC5H-6508-2370 50.8mm*9mm*2370.4mm

Flat bar handrail type A2 1 PCSBC6H-6508-1014 50.8mm*9mm*1014.6mm

Link plate 1 PCSBC2H-0090 50mm*3mm*90mm

Cover plate 8 PCSBC1C-2803 28mm*3mm

Link adjuster 8 PCSBC1A-1208 12mm*77mm

18 PCS- Flat head socket cap screw M8*1.25*20mmAccessories

6799-1815

16 PCS- Stud anchor- Adhesive capsule anchor (HVU)

M8*80mmPBH2-688016 PCS2 PCS

M8*80mmPBH3-0880

12 PCSM8*25mm- Screw 6933-0825

16 PCS- Domed nut M66158-761026 PCSM86158-7812

26 PCS1.5mm*8.5mm*18mm6914-1381- Washer

16 PCS6mm2000-2206- Right thread nut

6 PCS14.28mm*6mmBC2B-0006- Stanchion bush

3D Model 3D Model

M82955-0830- Threaded stud

4.1

6

3.1

1

8

3.27

5

4.2

9

2

2400

1100

2400

Balcony system A was designed for buildingswhich have a one side open balcony or a corner balcony. The system is very suitable for apartmentsand condominiums where there is a requirement for the balustrade to look modern & striking. Using wire infill for the balustrade balcony system, alongside stainless steel balusters, adds transparency, increasing the available view whilst remaining very safe for high floor balconies. System A also uses a continuous handrail, increasing aesthetic appeal and safety for the dwelling owner. The system is incredibly strong, safe & easy to install and because all of the component parts are made form 316 Stainless steel, the system will endure any weather for many years.

1.

2.

3.1

3.2

4.1

4.2

5.

7.

9.

8.

6.

Page 3: Strudyna Balcony System

Plan view

Balcony System B has been designed for apartments and condominiums with a narrow balcony, which is open on just one side. Because the application is for single sided balconies and incorporates wire infill, system B is very elegant with maximum transparency. Wire infill and steel balusters allow for a panoramic view from the balcony, barely obscuring views for its owners. Furthermore, for warmer countries, the lack of a paneled balustrade structure, e.g., Glass means that wind and fresh air are able to circulate freely. This system is a viable alternative to paneled systems, potentially adding value to any apartment or condo because of increased aesthetic and functional advantages over paneled systems. System B can be easily installed and again, because of the use of 316 Stainless in all components, the system has a high resistance to corrosive environmental circumstances that might leave other systems tarnished, or worse still in need of repair.

page

3

aaalllclclconononyyy SSSySySy ttstststememem BBBB BBBBaBaBa hhhhh hasasasas bbbbb beeeeeeeennnn dddededede iisisisisigngngngng ddedededed ffffff forororor ents and condominiums with a narrow balcony, apartmes open on just one side Because the applicationwhich is

BALCONYBALCONYsystemsystem B

www. strudyna.com

Sketch elevation front view

Balcony system B 3D Model

6 PCS14.28mm*6mmBC2B-0006- Stanchion bush

Assembly parts for Balcony system B for 1 setNO. Name Code Size

Stanchion base

Stanchion post type A (Middle)

1.

2

3.1

3.2

4

5

6

7

8

BC1B-1008

BC1P-MD90

Stanchion post type B (End)

for 1 set

3 PCS

1 PCS

2 PCSBC2P-EN90

51mm*90mm*85mm

40mm*9mm*874mm

40mm*9mm*874mm

Stanchion angle 8 PCSBC3H-0038 38mm*77mm*40mm

EM6 Deco stud 16 PCS2960-3630 3mm M6*30mm

Cable 1x19 8 PCSCX19-0003-2108 3mm*2108mm

Flat bar handrail type B 1 PCSBC1H-6508-2290 50.8mm*9mm*2290mm

Cover plate 4 PCSBC1C-2803 28mm*3mm

Link adjuster 4 PCSBC1A-1208 12mm*77mm

12 PCS- Flat head socket cap screw M8*1.25*20mmAccessories

6799-1815

12 PCS- Stud anchor- Adhesive capsule anchor (HVU)

M8*80mmPBH2-688012 PCSM8*80mmPBH3-0880

16 PCS- Domed nut M66158-761024 PCSM86158-781224 PCS1.5mm*8.5mm*18mm6914-1381- Washer16 PCS6mm2000-2206- Right thread nut

12 PCSM8*25mm- Screw 6933-0825

8

1

3.1

3.2

2

24

5

w 3D Model 3D Model

7

6

2 PCSM82955-0830- Threaded stud

2400

1100

S

page

Page 4: Strudyna Balcony System

Balcony System C has been designed for apartments and condominiums with larger balcony areas. In particular, its most suitable for long terraces and those built with corners. This system has real functional & aesthetic appeal due to the continuous wires which run the entire length of the balcony perimeter. Because of the use of wire infill as opposed to paneled sections, balcony system C helps the terrace look and feel very open, promoting panoramic views and a feelingof increased space. In warmer climates, the wire infill also aids the movement of air throughout the area, supporting a relaxing balcony / terrace environment. Balcony system C continues to champion the trend for transparency, safety and functionality whilst remaining easy to install and weather resistant. Like all of the Strudyna balcony systems, the use of 316 stainless steel in the system component means that the system will continue to look great and perform its primary functions for many years, with little maintenance required.

for alcony

etic n the se of

ectionss, feel feelingg

wire t the

on thety whilst

Lik

Sketch elevation front view

BALCONYBALCONYsystemsystem

4

C

viewview

Assembly parts for Balcony system C for 1 setNO. Name Code Size

Stanchion post type A (Middle)

2.1

2.2

3.1

3.2

CX19-0003-1577 3mm*1577 mm 8 PCS9.2

CX19-0003-0392 3mm*392 mm 8 PCS9.3

Link angle 90 degree BC2A-1208 12mm*95.5mm 6 PCS7.

BC1P-MD90

Stanchion post type B (End)

for 1 set

2 PCS

6 PCSBC2P-EN90

Stanchion base 1. BC1B-1008 8 PCS51mm*90mm*85mm

40mm*9mm*874mm

40mm*9mm*874mm

Stanchion angle 16 PCSBC3H-0038 38mm*77mm*40mmStanchion angle link 2 PCSBC4H-J113 113.5mm*77mm*40mm

8. EM6 Deco stud 48 PCS2960-3630 3mm M6*30mm

CX19-0003-2392 3mm*2392 mm 8 PCS9.1 Cable 1x19Cable 1x19Cable 1x19

BC7H-6508-1850 50.8mm*9mm*1850.8mm4.1 Flat bar handrail type C1 1 PCS

BC8H-6508-2564 50.8mm*9mm*2564.1mm4.2 Flat bar handrail type C2 1 PCS4.3 BC8H-6508-A564 50.8mm*9mm*564.1mmFlat bar handrail type C2 1 PCS

6. Cover plate 4 PCSBC1C-2803 28mm*3mm5. Link adjuster 4 PCSBC1A-1208 12mm*77mm

36 PCS- Flat head socket cap screw M8*1.25*20mmAccessories

6799-1815

22 PCS- Stud anchor- Adhesive capsule anchor (HVU)

M8*80mmPBH2-688022 PCSM8*80mmPBH3-0880

48 PCS- Domed nut M66158-761072 PCSM86158-781256 PCS1.5mm*8.5mm*18mm6914-1381- Washer48 PCS6mm2000-2206- Right thread nut16 PCS14.28mm*6mmBC2B-0006- Stanchion bush

32 PCSM8*25mm- Screw 6933-0825

Balcony system C 3D Model

9.3

4.3.

4.1.

1 7

8 9.2

2.2

9.1

3.2. 3.1.6

2.1.

2.1.

5

www. strudyna.com

3D Model 3D Model

2 PCSM82955-0830- Threaded stud

page 4

Plan view

2000

700

2000

Plan view

4.2.

Page 5: Strudyna Balcony System

4

- Flat head socket cap screwAccessories

- Stud anchor- Adhesive capsule anchor (HVU)

- Domed nut

- Washer- Right thread nut

- Screw

Assembly parts for Balcony system D (Commercial)No. Name

Stanchion post type A (Middle)

2.1

2.2

3.1

3.2

Link angle 90 degree7.

Stanchion post type B (End)

Stanchion base (Flexible) 1.

Stanchion angleStanchion angle link

8. Link for double stanchion post9.

10.

EM6 Deco stud

4. Flat bar handrail type D

6. Cover plate5. Link adjuster

Code

BC2A-0C08

BC1P-MD11

BC2P-EN11

BC3B-0008

BC3H-0038BC4H-J143

BC3A-1208

2960-3630

Contact sale team

BC1C-2803BC1A-1208

Size Name Code Size

12mm*131.5mm

50mm*100mm*90mm

40mm*9mm*1074mm

40mm*9mm*1074mm

38mm*77mm*40mm143.5mm*77mm*40mm

12mm*30mm

3mm M6*30 mm

Cable 1x19 CX19-0003-xxxx 3mm*xxxx mm

50.8mm*9mm*xxxxmm

28mm*3mm12mm*77mm

www. strudyna.com

M8*1.25*20mm

M8*80mm

M8*80mm

M6M8

1.5mm*8.5mm*18mm

6mm

M8*25mmM8*30mm

M8

6799-1815

PBH2-6880

PBH3-0880

6158-76106158-7812

6914-1381

2000-2206

6933-08256933-0830

2955-0830- Threaded stud

page 5

Balcony System D was developed for use in public areas, helping to create a modern visually appealing system that also compliments any existing building infrastructure. For use indoor or outside in public areas, Strudyna Balcony System D continues to promote maximum transparency, a departure from traditional paneled or solid balustrade which can restrict view’s and the movement of air. System D, like the systems detailed previously in this brochure, is very strong and safe with a tensioned wire infill. Wire infill promotes transparency and unrestricted views beyond any perimeter. In warmer countries, the wire infill also helps aid the movement of air in any space, helping to keep the environment cool and relaxing. Made with 316 stainless steel components, balcony system D is incredibly strong & corrosion resistant; the system is also very easy to install and maintain. These features arevery desirable in public areas, especially if the balustrade is very large as this equals a significant saving in terms of installationand ongoing operational expenditure. The system will continue to look great and last for years even inharsh environmental circumstances.

Balcony system D 3D Model

Strudyna Balcony system D (Commercial)

4 M.

15.6 M.

4.8 M.

Sketch elevation right side viewPlan view

3D Model

*See more assembly parts details at page 13-16

BALCONYBALCONYBALCONYsystemsystemsystem D

Page 6: Strudyna Balcony System

page 6www. strudyna.com

AA

Rule

AA

ule

A guide to specifying Strudyna Balcony Systems

Select the type of Strudyna Balcony System which is most suitable for your terrace or balcony. Picture 1

Refer to the criteria laid out in the standard IBC of America for the conditions governing balcony design and installation. These conditions and recommendations have been summarized below.

The condition of balcony installation1) Function : (See picture no.1) The balcony is appropriate with the private area and the public area; e.g. building, apartment or condominium. The height of balcony is specified as following this.1.1 The private area should apply to the height of balcony at 900 mm. 1.2 The public area should apply to the height of balcony at 1100 mm.2) The strength of the pole: (See the picture no.2)2.1 The force all directions at 0.85 kN/m (product is not damage.) 2.2 The pressure strength of cable at 0.22 kN/m (cable is not broken.)3) The gap: (See the picture no.3)3.1 The gap between the cable; the width should not be over 102 mm. (our product has the gap at 100 mm.)3.2 The gap between the poles should not be over 1200 mm. If it is over 1200 mm, it should have the pole at the centre.4) The size of handrails: The handrails as round type, the diameter should be 35-40 mm. For the other handrails should measure the perimeter between 102-160 mm. 5) The quantity of connector for the pole and wall5.1 Link adjuster used for connecting between pole and wall- Height of the pole 900mm use 2 pcs - Height of the pole 1,100mm use 3 pcs5.2 Link angle 90 degree connect at the angle of the pole- Height of the pole 900mm use 3 pcs - Height of the pole 1,100mm use 5 pcs6) The point of angle for the top handrail has to use the connector every points: (See the picture no.5)6.1 The balcony type A use the Link plate for connecting.6.2 The balcony type B use the Stanchion angle link L shape for connecting.7) Stainless steel anchor: (See picture no.6)7.1 Use Chemical anchor- the length from the edge of cement to the drilling hole is between 50-80mm.7.2 Use Metal anchor – the length from the edge of the cement to the drilling hole 80mm up.8) Cable fitting (EM6): (See picture no.4)8.1 Use with the cable 1x19.8.2 Cable dia 3.4mm .(for the mock up sample we use cable dia 3mm)8.3 The length of cable 3.4mm dia.per piece is not over 2400mm.8.4 The height of balcony 900mm, use the cable 8 pcs.8.5 The height of balcony 1100mm, use the cable 10 pcs.9) The whole structure: ( Balcony system type A, B, C & D )9.1 All the parts with the thread, the thread have to be right hand thread.9.2 Balcony system use the thread M6 and M8 only.9.3 All the parts with the thread M6, there are used for assembly with cable fittings only.

Private areaH 900 mm.

Force All directions 0.89 kN/m.

All gap = 100 mm.

Step 1

Step 2

Link Plate

Stanchion Angle Link

Min 50 mm.

Min 50 mm.

Picture 2

Picture 3

Picture 6Picture 5Picture 4

243

Private areaH 1,100 mm.

Page 7: Strudyna Balcony System

page 7www. strudyna.com

Howto

Hot

Balcony system A

A

11 2 3 4 5 6 7 8 9 10

3 42

owwowo

Study the installation guide and follow the installation steps detailed over the following pages.

Contact the Strudyna Sales team if you require further information regarding our proprietary Balcony Systems and their installation or if you are interested in additional products, services and capability available from Strudyna.

1. Prepare all components and tools

Electric drillHex wrench/Spanner

6, 10, 13

BT7991

BFWA/E1 SFNUT/RBNUT/DIN1587

PBH3

BC1A BC1CBC2A

BC3H BC4H (Link)

Tools Nuts & Bolts

Stanchion Post Components

See more information on page 15-16

For more information please see pages 13-15

Assembly & Installation Procedures for Strudyna Balcony Systems.

Step 3

Step 4

BC3BBC1B

BC2B

BC2HBC3A

BT933

BC1P, BC2P

900 1100

BC1H, BC5H, BC6HBC7H, BC8H

PBH1 PBH2

Page 8: Strudyna Balcony System

page 8www. strudyna.com

2. Once you have organized your balcony system components, carefully follow the installation guide as laid out below and in the following pages. Assemble each post as per the below diagrams

Angled connection for handrail to wall

Post Balcony Type A,B,C (Residential) 900 mm.

Post Balcony Type D (Commercial) 1100 mm.

Assembly Procedure for Strudyna Balcony Systems A, B, C & D

Type 5

End post Middle post Corner post

Handrail with link adjuster

Link plate detail

Type 1

Angled connection for handrail to wall

Type 2 Type 3 Type 4

Type 6

End post

Type 1

Middle post

Type 2

Double post

Type 3 Corner post

Type 4

*Recommended to use Type 3 double post for every 2400 mm. (refer to the length of cable per piece is not over 2400 mm)

Type 5

Page 9: Strudyna Balcony System

page 9www. strudyna.com

Handrail with link adjusterType 4

Link plate DetailType 5

Angled connection for handrail to wall

Type 6

NO. Name Code Size

Stanchion base

Assemble each post as per the below diagrams.

Stanchion post type A (Middle)

Link adjuster

Flat bar handrail type A1

Cover plate

Stanchion angle

2.1

2.2

1.

3.1

3.2

4.1

4.2

5.

6.

7.

8.

9.10.11.

12.13.

15.14.

BC1B-1008

BC1P-MD90

Stanchion post type B (End) BC2P-EN90

BC1A-1208

BC5H-6508-XXXX

BC1C-2803

BC3H-0038

51mm*90mm*85mm

40mm*9mm*874mm

40mm*9mm*874mm

38mm*77mm*40mm

Stanchion angle link BC4H-J113 113.5mm*77mm*40mm

50.8mm*9mm*XXXXmm

Flat bar handrail type A2 BC5H-6508-XXXX 50.8mm*9mm*XXXXmm

Link plate BC2H-0090 50mm*3mm*90mm

28mm*3mm

12mm*77mm

12mm*95.5mm

Flat head socket cap screw

M8

Accessories

Component

6799-18156933-0825

PBH2-6880PBH3-0880

6158-7812

6914-1381Washer

Screw

M8*30mm2955-0830Threaded studDome nut

Link angle 90 degree BC2A-1208

6.

9.

11

4.1

7.

4.1

4.2

7.

5.

12.

6.

9.

M8*1.25*20mm

Stud anchor Adhesive capsule anchor (HVU)

M8*80mm

M8*80mm

1.5mm*8.5mm*18mm

M8*25mm

14.28mm*6mmBC2B-0006Stanchion bush

End postType 1

1.

2.2

3.1

6.7. 9.

9.

10.

11

11

1015

13

13

13

13

14.

14.

Corner postType 3

1.1.

2.2 2.2

3.1

9.9.

9.

10.15.

10.

1111

13

13

13 133.2

13

14.

8.

13

14.

Middle postType 2

13

13

2.1

1.

3.1

9.

10.

11

15.

14.

14.14.

10.

13 13

Use with Stud anchor PBH2-6880

The Installation Procedures for Strudyna Balcony Systems A, B & C (Residential)

Page 10: Strudyna Balcony System

page 10www. strudyna.com

End postType 1

Corner postType 4

Middle postType 2

Double postType 3

NO. Name Code Size

Stanchion base (Flexible)

Assembly each post as below

Stanchion post type A (Middle)

Link adjuster

Cover plate

Stanchion angle

2.1

2.2

1.

3.1

3.2

4.

5.

6.

8.9.19.210.

12.

11.

BC3B-0008

BC1P-MD11

Stanchion post type B (End) BC2P-EN11

BC1A-1208

BC1C-2803

BC3H-0038

50mm*100mm*90mm

40mm*9mm*1,074mm

40mm*9mm*1,074mm

38mm*77mm*40mm

Stanchion angle link BC4H-J143 143.5mm*77mm*40mm

28mm*3mm

12mm*77mm

12mm*131.5mm

Flat head socket cap screw

M8

Accessories

Component

6799-18156933-0825

PBH2-6880PBH3-0880

6158-7812

6914-1381Washer

Screw

Dome nut

Link angle 90 degree BC2A-1208

5. 8.

3.1

3.2

M8*1.25*20mm

Stud anchor Adhesive capsule anchor (HVU)

M8*80mmM8*80mm

1.5mm*8.5mm*18mm

M8*25mm6933-0830 M8*30mm

7. 12mm*30mmBC3A-1208Link for double stanchion post

Use with Stud anchor PBH2-6880

Assembly Guide for Balcony System D (Commercial)

10.

10.

10.10.1.

11.

11.

11.

1.

11.

11.1.

3.1

3.13.1

2.2

8.

9.1

9.2

9.2 9.2

6.

1.

12.

12.

12.

12.

8.4.

10

12.

9.1 9.1

12.

12.11.

12.11.

12.

8. 8.

2.2

2.2

2.1

7

8.

8.

9.2

9.112.11.

Page 11: Strudyna Balcony System

Installation Guide for Strudyna Balcony System A, B & C (Residential)Tip For accurate installation, follow these 6 simple steps.

page 11www. strudyna.com

243

243

9 mm.

9 mm.

4.

1. 2. 3.

6.5.

Min 50 mm.

Ø 8 mm

Tip Use Loctite for safety.

243

Page 12: Strudyna Balcony System

Installation Guide for Strudyna Balcony System D (Commercial)Tip For accurate installation, follow these 6 simple steps.

page 12www. strudyna.com

243

243

9 mm.

9 mm.

Tip Use Loctite for Safety

4.

1. 2. 3.

6. 5.

Ø 8 mm

Min 100 cm.

243

Page 13: Strudyna Balcony System

www. strudyna.com page 13

Stanchion post

A

T

BC1P BC2P

BC1P

BC2P

type A(Middle)

type B(End)

Technical DataFlat bar material : AISI316

N/ASurface treatment : "M.F. " (Matte finished) TAP :

Order no.

BC1P-MD90

BC1P-MD11

BC2P-EN90

A (mm)

40

4040 9

BC2P-EN11 40 9

874

1074

L(mm)

874

107430

30

L1(mm)

30

30

T(mm)

9

99

9

ØD (mm)

9

96.9

6.9

ØD1(mm)

6.9

6.9

Stanchion post

L

L1

ØD ØD1

L1

Item

BC3H

Technical DataSheet material : AISI316L - DIN 1.4408Surface treatment : "M.F." (Matte finished)TAP : N/A

Order no.Item

T(mm)

A(mm)

BC3H-0038 40 3

40

L(mm)

38

113.5 3

B (mm)

77

77BC4H-J113

40 143.5 377BC4H-J143Stanchion angle

BC4H (Link)

A

T

L L

B

BC1B Order no.Item

Technical DataCasting material : AISI316 - DIN 1.4408Surface treatment : "M.F." (Matte finished)TAP : N/A

BC1B-1008

L1(mm)

90

T(mm)

8

A (mm)

51

B (mm)

30 85

H(mm)

L1

L1

T

T

B

B

H

H

A

A

Stanchion base

BC3B Order no.Item

Technical DataCasting material : AISI316 - DIN 1.4408Surface treatment : "M.F." (Matte finished)TAP : N/A

BC3B-0008 90

T(mm)

L1(mm)

100 10

A (mm)

50

B (mm)

30

H(mm)

Stanchion base

Ae)

ost

Page 14: Strudyna Balcony System

BC1A

Link adjuster

ØD

M

ØD(mm)

12

L(mm)

77

M(thread)

M8L

Order no.

BC1A-1208

Item

Technical DataBar material : AISI316Surface treatment : "M.F. " (Matte finished)TAP : N/A

L(mm)

131.595.5

ØD(mm)

1212

M (thread)

M8M8

M

L

Link angle 90 degree

BC2A Order no.

BC2A-0C08BC2A-1208

Item

Technical DataBar material : AISI316LSurface treatment : "M.F. " (Matte finished)TAP : N/A

Order no.

BC2H-0090

A(mm)

40

T(mm)

3

L(mm)

50

T

A

L

BC2H

Link plate

Item

Technical DataSheet material : AISI316LSurface treatment : "M.F. " (Matte finished)TAP : N/A

ML

ØD

ØD

Connector

A

T

BC1H, BC5H, BC6HBC7H, BC8H

Technical DataSheet material : AISI316

N/ASurface treatment : "M.F. " (Matte finished)TAP :

Order no.Item

L(mm)

A (mm)

BC5H-6508-XXXXBC6H-6508-XXXX

A1 A

B

C

TypeFor System

A2

BC1H-6508-XXXX B

50.850.8

50.8

50.850.8

T(mm)

9

99

99

BC7H-6508-XXXXBC8H-6508-XXXX

C1 C2

L

* Contact to Strudyna Sale team for checking the length and hole* Contact to Strudyna Sale team for more information of system D

selectselect

select

selectselect

H, BC5H, BC6HH, BC8H

Flat bar handrail

BC1C

Cover plateTechnical DataSheet material : AISI316LSurface treatment : "M.F. " (Matte finished)TAP : N/A

ØD(mm)

28

T(mm)

39

ØD1(mm)

Order no.

BC1C-2803

Item

TØD

ØD1

www. strudyna.comTAP : 27.1

page 14

Order no.

BC3A-1208

L(mm)

30

ØD (mm)

12

M (thread)

M8

ItemBC3A

Link for double stanchion postTechnical DataThreaded stud : Bar Forging material AISI316, EN 1.4401Surface treatment : Matt finishedTAP : N/A

Flat bar handrail

I316L: "M.F. : "M F : N/A

ble stanchion postble stanchion postble stanchion post: Bar Forging material

" (Matte finished)" (Ma

Page 15: Strudyna Balcony System

www. strudyna.com

Nuts & Bolts

Technical DataMaterial : AISI316 - DIN 1587

Order no.

6158-7610

M (thread)

M6M86158-7812

S.W. (mm)

1012.8

L(mm)

1215LDome nut

BNUT/DIN1587

S.W.

M

Item

Adhesive capsule for stud anchor PBH2-6880Technical DataMaterial : AISI316 - DIN 1.4401

L(mm)

M (thread)

75M8106M8LStud anchor

PBH2

PBH3

PBH1 L

M

M

Order no.

PBH1-6875PBH2-6880

PBH3-0880

Item

BT933

Technical Data Material : AISI316 - DIN 933

ØD (mm)

13

ItemOrder no.

6933-0825

6933-0830 13 30 M8

L(mm)

25

M (thread)

M8L

M

ØDScrew

TAP : 27.1

page 15

SF960

Cable Fitting

Order no.

2960-3630

Ø Cable(mm)

3

ØOD(mm)

6.35

L1(mm)

12

M(thread)

M6

L(mm)

30

EM6 deco stud cable

M

LL1

ØODItem

CX19

Order no.Size LengthItem

Ø Size (mm)

Order no.

CX19-0003-0000 3

Limit Tension(kN)

4.45

Hamma X 1x19

LOC2

Loctite 263L

ØD

Cable Lenght (mm)

select LOC2 - 6350 50 ml.

SizeTechnical DataCable material : AISI316Construction : Spiral strandConfiguration : 1x19 = 1+6+12Module of elasticity : 132 +/-10 kN/mmNote : Limit tension is calculated at 60% of MBL.

Technical DataBar material : AISI316LSurface treatment : "M.F. " (Matte finished)TAP : 57.10

BT7991 L(mm)

ØD (mm)

16 20

M (thread)

M8

Flat head socket cap screwL

M

ØD

Order no.

6799-1815

Item

Technical Data Material : AISI316 - DIN 7991

Order no. L(mm)

M (thread)

2955-0830 30M8

ItemSF955

Threaded stud

L

Ø M

Technical DataThreaded stud : Bar Forging material AISI316, EN 1.4401Surface treatment : Matt finishedTAP : N/A

AISI316 - DIN 1.4401

ded stud Data

tud : Bar Forging material

Page 16: Strudyna Balcony System

ACCESSORIES

MOCK UP BALCONY

Nuts & Bolts

T

BFWA/E1

Technical DataSheet material : AISI316Surface treatment : "E.P." (Electro polished)

Order no. T(mm)

ØD1(mm)

6914-1381 1.58.5Washer ØD

ØD1

Item

T

Order no. T(mm)

2000-2206

S.W. (mm)

105

M

S.W.

Item

Technical DataBar material : AISI316Surface treatment : "E.P. " (Electro polished)Bar material : AISI316

Right thread nut

SFNUT/R

www. strudyna.com page 16www. strudyna.com

Exclusive AgentsYear 2014

Keng Wah Hardware Co. Pte. Ltd.Blk 2 Kitchener Road #01-85Singapore 200002Tel : +(65) 6392 4896Fax : +(65) 6296 4736Email : [email protected]

Structural Dynamics Australia4 / 14 Dover Drive Burleigh Heads Queensland 4220 AustraliaTel : +07 5568 7084Fax : +07 5576 5166Email : [email protected]

Anzor Fasteners Ltd.8 Arrenway Drive Albany,Auckland, New ZealandTel : +(64) 9 476 0001Fax : +(64) 9 476 0090Email : [email protected]

Structural Dynamics Europe Limited.Unit 10 Wingate Rd. Gosport, Hampshire,UK. PO12 4DPTel : +44 (0) 845 262 5557Fax : +44 (0) 239 294 0272Email : [email protected]

TØDØD1

BC2B Order no. T(mm)

ØD1(mm)

ØD(mm)

18

M(thread)

M6

ØD(mm)

14.28BC2B-0006 68.45

Item

Stanchion bushTechnical Data Bar material : AISI316Surface treatment : Machine finished