26
Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Step by Step in DIALux With OSRAM LEDs

Embed Size (px)

DESCRIPTION

DIALUX Manual

Citation preview

Page 1: Step by Step in DIALux With OSRAM LEDs

Step by Step

Street Lighting Simulation

with OSRAM LEDs in DIALux

Page 2: Step by Step in DIALux With OSRAM LEDs

Agenda

Introduction and Install of DIALux

Import IES files of OSRAM LEDs

Quick Street Planning Wizard with DIALux

Step by Step – Design with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 2

Drr.MEC /c.channarong

Page

3

8

12

20

Page 3: Step by Step in DIALux With OSRAM LEDs

What is special about DIALux?

DIALux - a planning software for your project presentation.

Calculation: latest radiosity procedures, fast and always correct.

Results: Results can be printed out or transmitted as a pdf file. Each

view and each rendering can be saved as a .jpg file.

Interactive 3-D visualization: Simply move around the room.

Visualization: Use of textures and furniture for realistic rendering.

Photo realism: with integrated raytracing module.

False colours: False colours provide quantitative analysis of

complex geometries at a glance.

Movies: Walk through the photo realistic visualization of your light

planning and send the film to your customer via email.

Interaction: Import and export: .dwg and .dxf files can be imported

and exported with results after completion of the planning process.

DIALux Light: Easy to use, step-by-step lighting design.

Event / Title | December 17, 2008 | Page 3

Drr.MEC /c.channarong

Page 4: Step by Step in DIALux With OSRAM LEDs

Free Download DIALux from website

Download the DIALux Setup (version DIALux 4.5.0.1 ) from homepage (www.DIAL.de or

www.dialux.com) on your hard-disk.

Language available

– deutsch

– english

– fran็ ais

– italiano

– espa๑ol

– 中文

Download file size:

about 250MB

Event / Title | December 17, 2008 | Page 4

Drr.MEC /c.channarong

www.DIAL.de or www.dialux.com

Page 5: Step by Step in DIALux With OSRAM LEDs

Online Update

If you have already installed old version of DIALux, you could use “ online update” to

newest version.

In DIALux you will find a new menu named “Online”.

After selecting “Online Update…” DIALux automatically checks for newer versions of the

software and for new online PlugIns.

But it will take some time to finish update.

Event / Title | December 17, 2008 | Page 5

Drr.MEC /c.channarong

Page 6: Step by Step in DIALux With OSRAM LEDs

The DIALux User Interface

These three work areas enable effective and clearly arranged planning of lighting

installation with DIALux.

Project manager

with Inspector

Event / Title | December 17, 2008 | Page 6

Drr.MEC /c.channarong

CAD-Window

Task Pane

Page 7: Step by Step in DIALux With OSRAM LEDs

.IES or .Idt files

.IES or .Idt file describe the

information of light distribution,

luminous flux, and power.

.IES or .Idt file are very small

( only about 10K) compared to

ray data (about 200M).

OSRAM OS provide both .IES

(or .Idt) file and ray data of our

LED products on website.

Event / Title | December 17, 2008 | Page 8

Drr.MEC /c.channarong

Page 8: Step by Step in DIALux With OSRAM LEDs

Download .IES file of OSRAM LED from website

http://www.ledlightforyou.com

Tools & Downloads >> Optical Tools

Event / Title | December 17, 2008 | Page 9

Drr.MEC /c.channarong

Page 9: Step by Step in DIALux With OSRAM LEDs

Import .IES file to DIALux

Event / Title | December 17, 2008 | Page 10

Drr.MEC /c.channarong

Page 10: Step by Step in DIALux With OSRAM LEDs

Quick Street Planning Wizard

This wizard guides you through the quick planning for streets.

you will find the wizards in

the menu File >> Wizard

Event / Title | December 17, 2008 | Page 12

Drr.MEC /c.channarong

Page 11: Step by Step in DIALux With OSRAM LEDs

Street profile and illumination class

Street profile

Street name and maintenance factor are likewise inserted on this page.

In the following window you can fix the individual or combined valuation

fields for the street. In order to define photometric requirements for the

street, select an illumination class for every valuation field.

Event / Title | December 17, 2008 | Page 13

Drr.MEC /c.channarong

Page 12: Step by Step in DIALux With OSRAM LEDs

Luminaire arrangement

In the window Luminaire arrangement you can select a luminaire and place this

in an arrangement. (You need to import the IES file of OSRAM LEDs first,

otherwise you can only select the existing traditional luminaire in DIALux)

You can optimize the arrangement parameters depending on the predefined

photometric requirements.

Event / Title | December 17, 2008 | Page 14

Drr.MEC /c.channarong

Page 13: Step by Step in DIALux With OSRAM LEDs

Start Calculation

Afterwards a final dialogue will appear automatically. If you activate the checkbox, the generated

street will be calculated immediately.

Click on the Finish button and your street project will be displayed.

Event / Title | December 17, 2008 | Page 15

Drr.MEC /c.channarong

Page 14: Step by Step in DIALux With OSRAM LEDs

Rotate 3D View

Event / Title | December 17, 2008 | Page 16

Drr.MEC /c.channarong

Rotate 3D View; left-click and move the mouse

while holding the mouse button pressed.

Page 15: Step by Step in DIALux With OSRAM LEDs

3D light distribution Display

Help Rays for Luminaires / 3D light distribution Display / Show false colors in CAD

Event / Title | December 17, 2008 | Page 17

Drr.MEC /c.channarong

Page 16: Step by Step in DIALux With OSRAM LEDs

Show false colors in CAD

Display the 3D rendering in a false colour

rendering

Easy to check the illuminance uniformity

Freely scaleable value ranges and definable

colour gradients

Event / Title | December 17, 2008 | Page 18

Drr.MEC /c.channarong

Page 17: Step by Step in DIALux With OSRAM LEDs

Step 1: Collecting road information

Street profile, width, N of lanes, coating…

Information list before design:

1. Street location and photos

2. Width of street

3. N of lanes

4. Coating material

Decide the road classification and required E

according to street lighting standards

av and Uo

5. Existing mounting height or pole distance?

Information needed for lighting simulation

Event / Title | December 17, 2008 | Page 20

Drr.MEC /c.channarong

Page 18: Step by Step in DIALux With OSRAM LEDs

Step 2: Edit street in DIALux

Arrangement of street component according

to the road information.

Event / Title | December 17, 2008 | Page 21

Drr.MEC /c.channarong

Page 19: Step by Step in DIALux With OSRAM LEDs

Step 3: Decide which LED

CCT: from 5000K-6500K (LW, LUW)

(color bin and brightness group)

If need CCT from 4000K-5000K, can be mixed by LUW and LY.

Golden DRAGON

with Oval Lens

No need of secondary

optical design

Event / Title | December 17, 2008 | Page 22

Drr.MEC /c.channarong

Golden DRAGON Plus

Need lens or reflector

Higher brightness

Page 20: Step by Step in DIALux With OSRAM LEDs

Step 4: Change luminous flux

You can change the luminous flux and power here.

It’s related to how many LEDs in one lamp.

Event / Title | December 17, 2008 | Page 23

Drr.MEC /c.channarong

Page 21: Step by Step in DIALux With OSRAM LEDs

Step 5: luminaire arrangement

Lighting Class Single row

Double row,

Double row,

Normal methods of

luminaire arrangement

with offset opposing

Single row

Double row, opposing

Double row, with offset

Luminaire arrangement

will be decided based on

street profile

requirements

For LUW W5JM, Double

row, opposing was

recommended.

Road information

Uniformity

Figure

W ≤ 6m

N ≤ 2

0.4~0.5

W ≥ 8m

N ≥ 2

0.5~0.8

W ≥ 16m

N ≥ 4

0.5~0.8

! Rules

of

thumb

Event / Title | December 17, 2008 | Page 24

Drr.MEC /c.channarong

Page 22: Step by Step in DIALux With OSRAM LEDs

Step 6: Optimize arrangement parameters

Optimize arrangement parameters

Boom Length

(1) Mounting Height: 6m~10m

(2) Overhang: 1m~2m

(3) Boom Angle: 10 ฐ ~15 ฐ

(4) Boom Length: 1m~3m

(5) Pole Distance

These parameter will be optimized

according to street profile to achieve

best performance: Eavand Uo.

If a certain Uo was required, the most

economic mounting height and pole

distance could be optimized.

Lower distance, longer pole distance

could save energy and pole cost.

Event / Title | December 17, 2008 | Page 25

Drr.MEC /c.channarong

Boom Angle

Mounting Height

Overhang

(5)Pole Distance

Lamp

Page 23: Step by Step in DIALux With OSRAM LEDs

Step 7: calculation and

simulation

Change to double row, offset

2

Eav(lx) Emin(lx) Emax(lx) Uo Emin/Emax Double row, opposing

17 8.6 24 0.52 0.36

Not so uniform,

need to be improved

1

Optimized results

3

Eav(lx)

19

Emin(lx)

16

Emax(lx)

22

Uo

0.83

Emin/Emax

0.72

Event / Title | December 17, 2008 | Page 26

Drr.MEC /c.channarong

Page 24: Step by Step in DIALux With OSRAM LEDs

Step 8: Save the selected output as PDF file

Event / Title | December 17, 2008 | Page 27

Drr.MEC /c.channarong

Page 25: Step by Step in DIALux With OSRAM LEDs

Step 9: output design plan

Luminaire arrangement

Event / Title | December 17, 2008 | Page 28

Drr.MEC /c.channarong

Page 26: Step by Step in DIALux With OSRAM LEDs

Step 10: output simulation results

Isolines (E)

Table (E)

Eav(lx)

19

Emin(lx)

16

Emax(lx)

22

Uo

0.83

Emin/Emax

0.72

Main results

Event / Title | December 17, 2008 | Page 29

Drr.MEC /c.channarong