Steel Seismic Design

Embed Size (px)

DESCRIPTION

Steel Seismic Design

Citation preview

  • Steel Structures 10 - 1Instructional Material Complementing FEMA 451, Design Examples

    NEHRP RECOMMENDED PROVISIONSSEISMIC DESIGN OF STEEL STRUCTURES

    Context in NEHRP Recommended Provisions

    Steel behavior

    Reference standards and design strength

    Moment resisting frames

    Braced frames

    Other topics

    Summary

  • Steel Structures 10 - 2Instructional Material Complementing FEMA 451, Design Examples

    Steel Design: Context in ProvisionsDesign basis: Strength limit state

    Using the 2003 NEHRP Recommended Provisions:Load combination Chap. 4Seismic load analysis Chap. 5Components and attachments Chap. 6Design of steel structures Chap. 8

    AISC Seismicand others

  • Steel Structures 10 - 3Instructional Material Complementing FEMA 451, Design Examples

    Seismic Resisting SystemsUnbraced FramesJoints are:

    Rigid/FR/PR/Moment-resisting

    Seismic classes are:Special/intermediate/Ordinary/not detailed

    Braced Frames Concentric bracing Eccentric bracing

  • Steel Structures 10 - 4Instructional Material Complementing FEMA 451, Design Examples

    Monotonic Stress-Strain Behavior

  • Steel Structures 10 - 5Instructional Material Complementing FEMA 451, Design Examples

    Bending of Steel Beam

    M

    Strain slightly above yield strain

    Section near plastic

    Extreme fiber reachesyield strain and stress

    u

    y

    Strain Stress

    y

    y < < sh y

    y

    y

    sh

  • Steel Structures 10 - 6Instructional Material Complementing FEMA 451, Design Examples

    Plastic Hinge Formation

  • Steel Structures 10 - 7Instructional Material Complementing FEMA 451, Design Examples

    Cross - section DuctilityConceptual moment - curvature

    M

    y

    Mp

    My

    y u

    u u u

    y y y

    =

  • Steel Structures 10 - 8Instructional Material Complementing FEMA 451, Design Examples

    Moment CurvatureLaboratory Test -- Annealed W Beam

  • Steel Structures 10 - 9Instructional Material Complementing FEMA 451, Design Examples

    Behavior Modes For Beams

    OLM Elastic lateral tors. bucklingOHI Inelastic lateral tors. bucklingOJG Inelastic lateral tors. bucklingOJE Idealized behaviorOJK Strain hardening

    Mr

  • Steel Structures 10 - 10Instructional Material Complementing FEMA 451, Design Examples

    Flexural Ductility of Steel MembersPractical Limits

    1 Lateral torsional bucklingBrace well

    2 Local bucklingLimit width-to-thickness ratiosfor compression elements

    3 FractureAvoid by proper detailing

  • Steel Structures 10 - 11Instructional Material Complementing FEMA 451, Design Examples

    Local and Lateral Buckling

  • Steel Structures 10 - 12Instructional Material Complementing FEMA 451, Design Examples

    Lateral Torsional Buckling

  • Steel Structures 10 - 13Instructional Material Complementing FEMA 451, Design Examples

    Local Buckling

    ycr tbEk

    = 222

    )/)(1(12

    b

    t

    Classical plate buckling solution:

    Substituting = 0.3 and rearranging:

    yFkE

    tb 95.0

  • Steel Structures 10 - 14Instructional Material Complementing FEMA 451, Design Examples

    Local Bucklingcontinued

    0.38y

    b Et F

    With the plate buckling coefficient taken as 0.7 and an adjustment for residual stresses, the expression for b/t becomes:

    This is the slenderness requirement given in the AISC specification for compact flanges of I-shaped sections in bending. The coefficient is further reduced for sections to be used in seismic applications in the AISC Seismic specification

    0.3y

    b Et F

  • Steel Structures 10 - 15Instructional Material Complementing FEMA 451, Design Examples

    Welded Beam to Column Laboratory Test - 1960s

  • Steel Structures 10 - 16Instructional Material Complementing FEMA 451, Design Examples

    Bolted Beam to Column Laboratory Test - 1960s

  • Steel Structures 10 - 17Instructional Material Complementing FEMA 451, Design Examples

    Pre-Northridge Standard

  • Steel Structures 10 - 18Instructional Material Complementing FEMA 451, Design Examples

    Following the 1994 Northridge earthquake,

    numerous failures of steel beam-to-column moment

    connections were identified. This led to a multiyear,

    multimillion dollar FEMA-funded research effort known as the SAC joint

    venture. The failures caused a fundamental rethinking of

    the design of seismic resistant steel moment

    connections.

  • Steel Structures 10 - 19Instructional Material Complementing FEMA 451, Design Examples

    Bottom Flange Weld Fracture Propagating Through Column Flange and Web

  • Steel Structures 10 - 20Instructional Material Complementing FEMA 451, Design Examples

    Beam Bottom Flange Weld Fracture Causing a Column Divot Fracture

  • Steel Structures 10 - 21Instructional Material Complementing FEMA 451, Design Examples

    Northridge Failure

    Crack through weld

    Note backup barand runoff tab Bottom flange

    of beam

    Beamweb

  • Steel Structures 10 - 22Instructional Material Complementing FEMA 451, Design Examples

    Northridge Failure

    Columnflange

    Backup bar

    Beam flangeand web

  • Steel Structures 10 - 23Instructional Material Complementing FEMA 451, Design Examples

    Northridge Failures

    Column Flange HAZ Lamellar Tear

    Weld Weld Fusion Column Divot

  • Steel Structures 10 - 24Instructional Material Complementing FEMA 451, Design Examples

    Flexural Mechanics at a Joint

    12

    12

    Beam Moment Fw

    Fy

    1 2w yF Z F Z >

    21 1 2

    Cross Sections

    Fw

    Fy

  • Steel Structures 10 - 25Instructional Material Complementing FEMA 451, Design Examples

    Welded Steel Frames

    Northridge showed serious flaws. Problems correlated with:

    - Weld material, detail concept and workmanship- Beam yield strength and size- Panel zone yield

    Repairs and new design- Move yield away from column face(cover plates, haunches, dog bone)

    - Verify through tests SAC Project: FEMA Publications 350 through 354

  • Steel Structures 10 - 26Instructional Material Complementing FEMA 451, Design Examples

    Reduced Beam Section (RBS) Test SpecimenSAC Joint Venture

    Plastic Rotation (% rad)

    M

    o

    m

    e

    n

    t

    (

    M

    N

    -

    m

    )

    -4 -2 0 2 4-4

    -2

    0

    2

    4

    Graphics courtesy of Professor Chia-Ming Uang, University of California San Diego

  • Steel Structures 10 - 27Instructional Material Complementing FEMA 451, Design Examples

    T-stub Beam-Column TestSAC Joint Venture

    Photo courtesy of Professor Roberto Leon, Georgia Institute of Technology

  • Steel Structures 10 - 28Instructional Material Complementing FEMA 451, Design Examples

    T-Stub Failure Mechanisms

    Net section fracture in stem of T-stub

    Plastic hinge formation -- flange and web local buckling

    Photos courtesy of Professor Roberto Leon, Georgia Institute of Technology

  • Steel Structures 10 - 29Instructional Material Complementing FEMA 451, Design Examples

    Rotation (rad)-0.06 -0.04 -0.02 0.00 0.02 0.04 0.06

    M

    o

    m

    e

    n

    t

    (

    k

    -

    i

    n

    )

    -7000-6000-5000-4000-3000-2000-1000

    01000200030004000500060007000

    M

    o

    m

    e

    n

    t

    (

    k

    N

    -

    m

    )

    -700-600-500-400-300-200-1000100200300400500600700

    FS-03 - Moment/Rotation

    T-Stub Connection Moment Rotation Plot

    Graphic courtesy of Professor Roberto Leon, Georgia Institute of Technology

  • Steel Structures 10 - 30Instructional Material Complementing FEMA 451, Design Examples

    Extended Moment End-Plate Connection Results

    Photo courtesy of Professor Thomas Murray, Virginia Tech

  • Steel Structures 10 - 31Instructional Material Complementing FEMA 451, Design Examples

    Extended Moment End-Plate Connection Results

    Total Plastic Rotation (rad)-0.08 -0.06 -0.04 -0.02 0.00 0.02 0.04 0.06 0.08

    M

    o

    m

    e

    n

    t

    a

    t

    C

    o

    l

    u

    m

    n

    C

    e

    n

    t

    e

    r

    l

    i

    n

    e

    (

    i

    n

    -

    k

    i

    p

    s

    )

    -25000

    -20000

    -15000

    -10000

    -5000

    0

    5000

    10000

    15000

    20000

    25000

    (b) Moment vs Plastic Rotation(a) Moment vs Total Rotation

    Total Rotation (rad)-0.08 -0.06 -0.04 -0.02 0.00 0.02 0.04 0.06 0.08

    M

    o

    m

    e

    n

    t

    a

    t

    C

    o

    l

    u

    m

    n

    C

    e

    n

    t

    e

    r

    l

    i

    n

    e

    (

    i

    n

    -

    k

    i

    p

    s

    )

    -25000

    -20000

    -15000

    -10000

    -5000

    0

    5000

    10000

    15000

    20000

    25000

    Graphics courtesy of Professor Thomas Murray, Virginia Tech

  • Steel Structures 10 - 32Instructional Material Complementing FEMA 451, Design Examples

    Ductility of Steel Frame JointsLimits

    Welded Joints- Brittle fracture of weld- Lamellar tearing of base metal- Joint design, testing, and inspection

    Bolted Joints- Fracture at net cross-section- Excessive slip

    Joint Too Weak For Member- Shear in joint panel

  • Steel Structures 10 - 33Instructional Material Complementing FEMA 451, Design Examples

    Multistory FrameLaboratory Test

  • Steel Structures 10 - 34Instructional Material Complementing FEMA 451, Design Examples

    Flexural DuctilityEffect of Axial Load

    0.10 ===p

    pc

    y MM

    PPe

    57.0MM

    55.0PP"10.5e

    p

    pc

    y

    ===

    28.0MM

    76.0PP"75.1e

    p

    pc

    y

    ===

    0.7rLx

    =

    W12x36

  • Steel Structures 10 - 35Instructional Material Complementing FEMA 451, Design Examples

    Axial StrutLaboratory test

    45rL =

  • Steel Structures 10 - 36Instructional Material Complementing FEMA 451, Design Examples

    Cross Braced FrameLaboratory test

  • Steel Structures 10 - 37Instructional Material Complementing FEMA 451, Design Examples

    Tension Rod (Counter) BracingConceptual Behavior

    H

    SlapbackFor cycle 2

    H

  • Steel Structures 10 - 38Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced Frame

  • Steel Structures 10 - 39Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FrameLab test of link

  • Steel Structures 10 - 40Instructional Material Complementing FEMA 451, Design Examples

    Steel Behavior Ductility

    - Material inherently ductile- Ductility of structure < ductility of material

    Damping- Welded structures have low damping- More damping in bolted structures dueto slip at connections

    - Primary energy absorption is yielding ofmembers

  • Steel Structures 10 - 41Instructional Material Complementing FEMA 451, Design Examples

    Steel Behavior Buckling

    - Most common steel failure under earthquake loads- Usually not ductile- Local buckling of portion of member- Global buckling of member- Global buckling of structure

    Fracture- Nonductile failure mode under earthquake loads- Heavy welded connections susceptible

  • Steel Structures 10 - 42Instructional Material Complementing FEMA 451, Design Examples

    NEHRP Recommended ProvisionsSteel Design

    Context in NEHRP Recommended Provisions

    Steel behavior

    Reference standards and design strength

  • Steel Structures 10 - 43Instructional Material Complementing FEMA 451, Design Examples

  • Steel Structures 10 - 44Instructional Material Complementing FEMA 451, Design Examples

    Using Reference StandardsStructural Steel

    Both the AISC LRFD and ASD methodologies are presented in a unified format in both the Specification for Structural Steel Buildings and the Seismic Provisions for Structural Steel Buildings.

  • Steel Structures 10 - 45Instructional Material Complementing FEMA 451, Design Examples

  • Steel Structures 10 - 46Instructional Material Complementing FEMA 451, Design Examples

    Other Steel MembersSteel Joist Institute

    Standard Specifications, 2002

    Steel CablesASCE 19-1996

    Steel Deck InstituteDiaphragm Design Manual, 3rd Ed., 2005

  • Steel Structures 10 - 47Instructional Material Complementing FEMA 451, Design Examples

    NEHRP Recommended ProvisionsSteel Design

    Context in NEHRP Recommended Provisions

    Steel behavior

    Reference standards and design strength

    Moment resisting frames

  • Steel Structures 10 - 48Instructional Material Complementing FEMA 451, Design Examples

    Steel Moment Frame Joints

    Frame Test i Details Special Reqd 0.04 Many

    Intermediate Reqd 0.02 Moderate

    Ordinary Allowed NA Few

  • Steel Structures 10 - 49Instructional Material Complementing FEMA 451, Design Examples

    Steel Moment Frame Joints

    u pa bM M

    b+

    *y y yF R F=

    * *1 1.7u y yf

    a bF F Z Fb A d+

  • Steel Structures 10 - 50Instructional Material Complementing FEMA 451, Design Examples

    Panel Zones

    Special and intermediate moment frame:

    Shear strength demand:

    Basic load combination or RyMp of beams Shear capacity equation

    Thickness (for buckling)

    Use of doubler plates

  • Steel Structures 10 - 51Instructional Material Complementing FEMA 451, Design Examples

    Steel Moment Frames Beam shear: 1.1RyMp + gravity

    Beam local buckling - Smaller b/t than LRFD for plastic design

    Continuity plates in joint per tests

    Strong column - weak beam rule- Prevent column yield except in panel zone- Exceptions: Low axial load, strong stories, top story,and non-SRS columns

  • Steel Structures 10 - 52Instructional Material Complementing FEMA 451, Design Examples

    Steel Moment Frames

    Lateral support of column flange- Top of beam if column elastic- Top and bottom of beam otherwise- Amplified forces for unrestrained

    Lateral support of beams- Both flanges- Spacing < 0.086ryE/Fy

  • Steel Structures 10 - 53Instructional Material Complementing FEMA 451, Design Examples

    Prequalified Connections

    See FEMA 350: Recommended Seismic Design Criteria forNew Steel Moment-Frame Buildings

    -Welded Unreinforced Flange -Bolted Unstiffened End Plate Connection-Welded Free Flange Connection -Bolted Stiffened End Plate Connection-Welded Flange Plate Connection -Bolted Flange Plate Connection-Reduced Beam Section Connections

    See ANSI/AISC 358-05, Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications

    -Reduced Beam Section Connections-Bolted Stiffened and Unstiffened Extended Moment End Plate Connections

  • Steel Structures 10 - 54Instructional Material Complementing FEMA 451, Design Examples

    Welded Coverplates

  • Steel Structures 10 - 55Instructional Material Complementing FEMA 451, Design Examples

    Reduced Beam Section (RBS)

  • Steel Structures 10 - 56Instructional Material Complementing FEMA 451, Design Examples

    Extended End Plate

  • Steel Structures 10 - 57Instructional Material Complementing FEMA 451, Design Examples

    Excellent Moment Frame Behavior

  • Steel Structures 10 - 58Instructional Material Complementing FEMA 451, Design Examples

    Excellent Moment Frame Behavior

  • Steel Structures 10 - 59Instructional Material Complementing FEMA 451, Design Examples

    Excellent Moment Frame Behavior

  • Steel Structures 10 - 60Instructional Material Complementing FEMA 451, Design Examples

    Special Moment FramesExample

    5

    a

    t

    2

    5

    '

    -

    0

    "

    N

    7 at 25'-0"

  • Steel Structures 10 - 61Instructional Material Complementing FEMA 451, Design Examples

    Special Moment Frames

    The following design steps will be reviewed: Select preliminary member sizes Check member local stability Check deflection and drift Check torsional amplification Check the column-beam moment ratio rule Check shear requirement at panel zone Select connection configuration

  • Steel Structures 10 - 62Instructional Material Complementing FEMA 451, Design Examples

    Special Moment Frames

    Select preliminary member sizes The preliminary member sizes are given in the next slide for the frame in the East-West direction. These members were selected based on the use of a 3D stiffness model in the program RAMFRAME. As will be discussed in a subsequent slide, the drift requirements controlled the design of these members.

  • Steel Structures 10 - 63Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Preliminary Member Sizes

  • Steel Structures 10 - 64Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Check Member Local Stability

    bf

    tf

    twhc

    Check beam flange:(W33x141 A992)

    Upper limit:

    Check beam web:

    Upper limit:

    6.012

    f

    f

    bt=

    0.3 7.22y

    EF

    =

    49.6cw

    ht

    =

    3.76 90.6y

    EF

    =

    OK

    OK

  • Steel Structures 10 - 65Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Check Deflection and DriftThe frame was checked for an allowable story drift limit of 0.020hsx. All stories in the building met the limit. Note that the NEHRP Recommended Provisions Sec. 4.3.2.3 requires the following check for vertical irregularity:

    2

    3

    5.17 .268 . 0.98 1.33.14 .160 .

    d x story

    d x story

    inC in

    inCin

    = =

  • Steel Structures 10 - 66Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Check Torsional Amplification

    The torsional amplification factor is given below. If Ax < 1.0 then torsional amplification is not required. From the expression it is apparent that if max / avg is less than 1.2, then torsional amplification will not be required.

    2

    max

    1.2x avgA

    = The 3D analysis results, as shown in FEMA 451, indicate that none of the max / avg ratios exceed 1.2; therefore, there is no torsional amplification.

  • Steel Structures 10 - 67Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Member Design NEHRP Guide

    Member Design Considerations - Because Pu/Pn is typically less than 0.4 for the columns, combinations involving 0 factors do not come into play for the special steel moment frames (re: AISC Seismic Sec. 8.3). In sizing columns (and beams) for strength one should satisfy the most severe value from interaction equations. However, the frame in this example is controlled by drift. So, with both strength and drift requirements satisfied, we will check the column-beam moment ratio and the panel zone shear.

  • Steel Structures 10 - 68Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Column-Beam Moment Ratio

    Per AISC Seismic Sec. 9.6*

    * 1.0pc

    pb

    MM

    >where M*pc = the sum of the moments in the column above and below the joint at the intersection of the beam and column centerlines. M*pc is determined by summing the projections of the nominal flexural strengths of the columns above and below thejoint to the beam centerline with a reduction for the axial force in the column.M*pb = the sum of the moments in the beams at the intersection of the beam and column centerlines.

  • Steel Structures 10 - 69Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Column-Beam Moment Ratio

    Column W14x370; beam W33x141

    * 22

    *

    5002 736 50109

    66,850

    ucpc c yc

    g

    pc

    P kipsM Z F in ksiA in

    M in kips

    = = =

    Adjust this by the ratio of average story height to average clear height between beams.

    * 268 . 160 .66,850 75,300251.35 . 128.44 .pc

    in inM in kips in kipsin in

    + = = +

  • Steel Structures 10 - 70Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Column-Beam Moment RatioFor beams:

    ( )( )( ) ( ) ( )

    *

    ' 2

    ' 2'

    2

    (1.1 )

    . ./ 2 / 2 25.61 .

    222 / 2

    1.046 248.8 .2 25,700

    12 2

    248.8 .

    pb y p v

    v p h

    h

    c b

    p

    p

    p p

    M R M M

    with M V S

    S dist fromcol centerline to plastic hinged d in

    V shear at plastic hinge location

    wLMV M wL

    L

    klf inin kips

    in

    = +=== + ==

    + = + = + = 221.2kips=

  • Steel Structures 10 - 71Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Column-Beam Moment Ratio

    *

    (221.2 )(25.61 .) 5,665

    (1.1 )

    2[(1.1)(1.1)(25,700 ) 5,665 ] 73,500

    v p h

    pb y p v

    M V S kips in in kips

    andM R M M

    in kips in kips in kips

    = = =

    = += + =

    The ratio of column moment strengths to beam moment strengths iscomputed as:

    *

    *75,300 1.02 1.0073,500

    pc

    pb

    M in kipsRatio OKM in kips

    = = = >

    Other ratios are also computed to be greater than 1.0

  • Steel Structures 10 - 72Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Panel Zone CheckThe 2005 AISC Seismic specification is used to check the panel zone strength. Note that FEMA 350 contains a different methodology, but only the most recent AISC provisions will be used. From analysis shown in the NEHRP Design Examples volume(FEMA 451), the factored strength that the panel zone at Story 2 of the frame in the EW direction must resist is 1,883 kips.

    2 23 (3)(16.475 .)(2.66)0.6 1 (0.6)(50 )(17.92 .)( ) 1(33.3 .)(17.92 .)( )

    537.6 315

    ( ) determined :

    (1

    cf cfv y c p p

    b c p p

    v p

    v u

    b t inR F d t ksi in td d t in in t

    R t

    The required total web plus doubler plate thickness is byR R

    = + = + = +

    =.0)(537.6 315) 1,883

    2.91 .

    1.66 ., :1.25 . ( 1.25 . 0.625 . )

    required

    doubler

    p

    p

    p

    t kips

    t in

    The column web thickness is in therefore the required doubler plate thickness ist in therefore use one in plate or two in plates

    + ==

    =

  • Steel Structures 10 - 73Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Connection Configuration

  • Steel Structures 10 - 74Instructional Material Complementing FEMA 451, Design Examples

    SMF Example Connection Configuration

  • Steel Structures 10 - 75Instructional Material Complementing FEMA 451, Design Examples

    Special Moment FramesSummary

    Beam to column connection capacitySelect preliminary member sizesCheck member local stabilityCheck deflection and driftCheck torsional amplificationCheck the column-beam moment ratio ruleCheck shear requirement at panel zoneSelect connection configuration

    Prequalified connections

    Testing

  • Steel Structures 10 - 76Instructional Material Complementing FEMA 451, Design Examples

    NEHRP Recommended ProvisionsSteel Design

    Context in Provisions Steel behavior Reference standards and design strength Seismic design category requirement Moment resisting frames Braced frames

  • Steel Structures 10 - 77Instructional Material Complementing FEMA 451, Design Examples

    Concentrically Braced FramesBasic Configurations

    X Diagonal K

    VInverted V K

  • Steel Structures 10 - 78Instructional Material Complementing FEMA 451, Design Examples

    Braced Frame Under Construction

  • Steel Structures 10 - 79Instructional Material Complementing FEMA 451, Design Examples

    Braced Frame Under Construction

  • Steel Structures 10 - 80Instructional Material Complementing FEMA 451, Design Examples

    Concentrically Braced Frames

    Special AISC Seismic R = 6Chapter 13

    Ordinary AISC Seismic R = 3.25Chapter 14

    Not Detailed for Seismic R = 3AISC LRFD

  • Steel Structures 10 - 81Instructional Material Complementing FEMA 451, Design Examples

    Concentrically Braced Frames

    Dissipate energy after onset of global buckling by avoiding brittle failures:

    Minimize local buckling

    Strong and tough end connections

    Better coupling of built-up members

  • Steel Structures 10 - 82Instructional Material Complementing FEMA 451, Design Examples

    Concentrically Braced FramesSpecial and Ordinary

    Bracing members:

    - Compression capacity = cPn- Width / thickness limits

    Generally compact

    Angles, tubes and pipes very compact

    - Overall

    - Balanced tension and compressionyF

    ErKL 4

  • Steel Structures 10 - 83Instructional Material Complementing FEMA 451, Design Examples

    Concentrically Braced FramesSpecial concentrically braced frames

    Brace connectionsAxial tensile strength > smallest of:

    Axial tension strength = RyFyAg Maximum load effect that can be transmitted to

    brace by system.Axial compressive strength 1.1RyPn where Pn is the

    nominal compressive strength of the brace.Flexural strength > 1.1RyMp or rotate to permit

    brace buckling while resisting AgFCR

  • Steel Structures 10 - 84Instructional Material Complementing FEMA 451, Design Examples

    Concentrically Braced FramesV bracing: Design beam for D + L + unbalanced brace forces,

    using 0.3Pc for compression and RyFyAg in tension Laterally brace the beam Beams between columns shall be continuous.K bracing: Not permitted

  • Steel Structures 10 - 85Instructional Material Complementing FEMA 451, Design Examples

    Concentrically Braced FramesBuilt-up member stitches:

    Spacing < 40% KL/r No bolts in middle quarter of span Minimum strengths related to Py

    Column in CBF: Same local buckling rules as brace members Splices resist moments

  • Steel Structures 10 - 86Instructional Material Complementing FEMA 451, Design Examples

    Concentrically Braced Frame

    Example

    E-W direction

  • Steel Structures 10 - 87Instructional Material Complementing FEMA 451, Design Examples

    Concentrically Braced Frame Example

    The following general design steps are required: Selection of preliminary member sizes Check strength Check drift Check torsional amplification Connection design

  • Steel Structures 10 - 88Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced Frames

    Link

    Brace

    Beam

  • Steel Structures 10 - 89Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced Frame Under Construction

  • Steel Structures 10 - 90Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced Frame Under Construction

  • Steel Structures 10 - 91Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced Frames

    Eccentric bracing systems R CdBuilding frame system or part ofdual system w/ special moment frame

    With moment resisting connections 8 4at columns away from links

    Without moment resisting connections 7 4at columns away from links

    These connectionsdetermine classification

  • Steel Structures 10 - 92Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FramesDesign Procedure

    1. Elastic analysis2. Check rotation angle; reproportion as required3. Design check for strength4. Design connection details

  • Steel Structures 10 - 93Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FramesExample

  • Steel Structures 10 - 94Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FramesRotation Angle

    1. Compute total = Cd E

    2. Deform model as rigid-plastic mechanism with hinges at ends of line

    3. Compute rotation angle at end of link

    p

    p

    p

    p

    p

    p

    p

    p

    VM

    LVM

    whenforeInterpolat

    VM

    Lwhenradians

    VM

    Lwhenradians

    6.26.1

    6.202.0

    6.108.0

  • Steel Structures 10 - 95Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FramesRotation Angle Example

    8.5' 3.0' 8.5'

    1

    2

    .

    6

    7

    '

    From computer analysis:

    Total drift:

    From geometry:

    0.247e in =

    4(0.247) 0.99 .d eC in = = =

    ( )

    max

    20 0.99 0.0433 12.67 12

    1.63.0 ' 3.52'

    0.08 0.043

    p

    y

    L rade

    MBecause e

    F

    rad rad OK

    = = = = < =

    = >

  • Steel Structures 10 - 96Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FramesRotation Angle

    Rotation angle limits based on link beam equivalent length

    - Short links yield in shear and are allowedgreater rotation

    Rotation angle may be reduced in design by:

    - Increasing member size (reducing e)- Changing geometric configuration(especially changing length of link beam)

  • Steel Structures 10 - 97Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FramesLink Design

    Provide strength V and M per load combinations Check lateral bracing per AISC Lpd Local buckling (width to thickness of web and

    flange) per AISC Seismic Stiffeners (end and intermediate) per

    AISC Seismic

  • Steel Structures 10 - 98Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FramesBrace Design

    > linkofstrengthshear designfromforceaxialR25.1Strength y

  • Steel Structures 10 - 99Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FramesBrace Design Example

    Check axial strength of 15.26 ft long TS 8 x 8 x 5/8 Fy = 46 ksi:

    ( )

    ( )( )

    2 2

    2 2

    4676.4

    (1)(15.26) 1261.2

    2.99

    61.2 4.71 118.3 0.658

    (29,000) 76.461.2

    0.658 46 35.8

    0.9 16.4 35.8 528

    y

    e

    FF

    cr yy

    e

    cr

    c n c g cr

    KLr

    E F FF

    EF ksiKLr

    F ksi

    P A F kip

    = = < = =

    = = = = = = = =

  • Steel Structures 10 - 100Instructional Material Complementing FEMA 451, Design Examples

    Eccentrically Braced FramesBrace Design Example

    ( )( )( )( )( )( )

    ( )

    0.9(0.6 ) 0.9 0.6 50 16.4 0.43 190

    2 0.9 50 1052(0.9) / 262.5

    3 12

    w

    p

    n y

    n

    V F d t kip

    or

    V M e kip

    = = =

    = = =

    ( ) ( )

    ( ) ( )85.2 120.2

    1901.25 1.1 120.2 369 52885.2

    e link e brace

    u

    V kip and P kip

    P OK

    = =

    = =

  • Steel Structures 10 - 101Instructional Material Complementing FEMA 451, Design Examples

    NEHRP Recommended ProvisionsSteel Design

    Context in NEHRP Recommended Provisions

    Steel behavior

    Reference standards and design strength

    Moment resisting frames

    Braced frames

    Other topics

  • Steel Structures 10 - 102Instructional Material Complementing FEMA 451, Design Examples

    Special Truss Moment Frame

    Buckling and yieldingin special section

    Design to be elasticoutside special section

    Deforms similar to EBF

    Special panels to be symmetric X orVierendeel

  • Steel Structures 10 - 103Instructional Material Complementing FEMA 451, Design Examples

    Special Truss Moment Frame

    Geometric Limits:

    5.2tb,diagonalsbarFlat

    23

    dL

    32

    5.0LL1.0

    '6d'65L

    p

    s

  • Steel Structures 10 - 104Instructional Material Complementing FEMA 451, Design Examples

    Special Truss Moment Frame

    ( )22 sin 0.3pcp nt cds

    i i p

    MV P P

    L

    F h V L

    = + +

    =

  • Steel Structures 10 - 105Instructional Material Complementing FEMA 451, Design Examples

    Special Truss Moment Frame

  • Steel Structures 10 - 106Instructional Material Complementing FEMA 451, Design Examples

    Special Truss Moment Frame

  • Steel Structures 10 - 107Instructional Material Complementing FEMA 451, Design Examples

    General Seismic DetailingMaterials:

    Limit to lower strengths and higher ductilities

    Bolted Joints: Fully tensioned high strength bolts Limit on bearing

  • Steel Structures 10 - 108Instructional Material Complementing FEMA 451, Design Examples

    General Seismic DetailingWelded Joints:

    AWS requirements for welding procedure specs Filler metal toughness

    CVN > 20 ft-lb @ -20F, or AISC Seismic App. X Warning on discontinuities, tack welds, run offs,

    gouges, etc.Columns:

    Strength using o if Pu / Pn > 0.4 Splices: Requirements on partial pen welds and

    fillet welds

  • Steel Structures 10 - 109Instructional Material Complementing FEMA 451, Design Examples

    Steel DiaphragmExample

    Vn = (approved strength)

    = 0.6

    For example only:Use approved strength as 2.0 x working load inSDI Diaphragm Design Manual

  • Steel Structures 10 - 110Instructional Material Complementing FEMA 451, Design Examples

    Steel Deck Diaphragm ExampleL

    dVE VE

    wE

    plf500w0ww

    '40d'80L

    ELD =====

    ( ) plf4176.02500

    2vv

    plf50040

    20000v;kip202LwV

    ESDI

    EE

    E

    ===

    ====

    Deck chosen:1 , 22 gage with welds on 36/5 pattern and 3sidelap fasteners, spanning 5-0

    Capacity = 450 > 417 plf

  • Steel Structures 10 - 111Instructional Material Complementing FEMA 451, Design Examples

    Welded Shear Studs

  • Steel Structures 10 - 112Instructional Material Complementing FEMA 451, Design Examples

    Shear Stud Strength - AISC 2005 Specification

    Qn = 0.5 Asc ( fc Ec)1/2 Rg Rp Asc FuRg = stud geometry adjustment factorRp = stud position adjustment factor

    Note that the strength reduction factor for bending has been increased from 0.85 to 0.9. This results from the strength model for shear studs being more accurate, although the result for Qn is lower in the 2005 specification.

  • Steel Structures 10 - 113Instructional Material Complementing FEMA 451, Design Examples

    Rg = 1.0 Rg = 1.0* Rg = 0.85 Rg = 0.7

    Shear Studs Group Adjustment Factor

    *0.85 if wr/hr < 1.5

    Qn = 0.5 Asc ( fc Ec)1/2 Rg Rp Asc FuRg = stud group adjustment factor

  • Steel Structures 10 - 114Instructional Material Complementing FEMA 451, Design Examples

    Shear Studs Position Adjustment Factor

    Rp = 0.75 (strong)= 0.6 (weak)

    Rp = 1.0 Rp = 0.75

    DeckNo Deck

    Qn = 0.5 Asc ( fc Ec)1/2 Rg Rp Asc FuRp = stud position adjustment factor

  • Steel Structures 10 - 115Instructional Material Complementing FEMA 451, Design Examples

    Shear Studs Strength Calculation Model Comparison

    0

    5

    10

    15

    20

    25

    30

    35

    0 5 10 15 20 25 30 35

    AISC Predicted Stud Strength, QN (k)

    E

    x

    p

    e

    r

    i

    m

    e

    n

    t

    a

    l

    S

    t

    u

    d

    S

    t

    r

    e

    n

    g

    t

    h

    ,

    Q

    e

    (

    k

    )

    S Studs2S StudsW Studs

    Qe=QN

    0

    5

    10

    15

    20

    25

    0 5 10 15 20 25

    Predicted Stud Strength, Qsc (k)

    E

    x

    p

    e

    r

    i

    m

    e

    n

    t

    a

    l

    S

    t

    u

    d

    S

    t

    r

    e

    n

    g

    t

    h

    ,

    Q

    e

    (

    k

    )

    Qe=Qsc

    AISC Seismic prior to 2005

    Virginia Tech strength model

  • Steel Structures 10 - 116Instructional Material Complementing FEMA 451, Design Examples

    Shear Studs Diaphragm Applications

    Shear studs are often used along diaphragm collector members to transfer the shear from the slab into the frame. The shear stud calculation model in the 2005 AISC specification can be used to compute the nominal shear strengths. A strength reduction factor should be used when comparing these values to the factored shear. There is no code-established value for the strength reduction factor. A value of 0.8 is recommended pending further development.

  • Steel Structures 10 - 117Instructional Material Complementing FEMA 451, Design Examples

    Inspection and TestingInspection Requirements

    Welding:- Single pass fillet or resistance welds

    > PERIODIC- All other welds

    > CONTINUOUS

    High strength bolts:> PERIODIC

  • Steel Structures 10 - 118Instructional Material Complementing FEMA 451, Design Examples

    Inspection and TestingShop Certification

    Domestic:- AISC- Local jurisdictions

    Foreign:- No established international criteria

  • Steel Structures 10 - 119Instructional Material Complementing FEMA 451, Design Examples

    Inspection and TestingBase Metal Testing

    More than 1-1/2 inches thick

    Subjected to through-thickness weld shrinkage

    Lamellar tearing

    Ultrasonic testing

  • Steel Structures 10 - 120Instructional Material Complementing FEMA 451, Design Examples

    NEHRP Recommended ProvisionsSteel Design

    Context in Provisions

    Steel behavior

    Reference standards and design strength

    Moment resisting frames

    Braced frames

    Other topics

    Summary