Stationary Meter Test System
GENY's meter test systems adopt the most advanced electronic measurement technique and modular concept,combining the
different reference standards and power amplifier to meet customers ' requirements in electric power departments, electric
energy meter manufacturers,measuring and quality examining departments and factories or enterprises.
The meter test systems can measure mechanical meters, electronic watt-hour meters and smart
meters by the way of automatic, semi-automatic or manual operation.
Aluminum alloy material, light and strong and corrosion resistant.
Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.
The swing together of the scanning heads simplifies the control.
Starting Test and Creeping Test.
Measuring different constants of meters synchronously.
With the protection function of overload, short voltage circuit and open current circuit.
The testing software with friendly Window 2000 and XP operation system, includes functional module of all
kinds of modern energy meter needed, to reality error test, harmonic test, demand test , influence test etc.
The stored testing data can be transferred to multi-format for other program use.
YC1891D Single Phase Meter Test System
Meters under testing: 3P4W, 3P3W, 1P2W
Testing mode: active power, reactive power,
cross connected reactive power
Installing the ICT in each meter position to test
three-phase meters with closed links between
the current and voltage measuring circuits
Neutral current test
Installing RS232, Ethernet communication port in each
meter position, to reality the automatic calibrate of
electronic meter
YC1893D Three Phase Meter Test System
Meters under testing: 1P2W
Testing mode: active power, reactive power
With MSVT,can test single-phase meters with
closed links between the current and voltage
measuring circuits (I-P links)
With current output switch,can calibrate 2-
element meters(optional)
Installing Rs232, Ethernet communication ports
in each meter position,to realize automatic
calibration of electronic meters(optional)
1
Features & Functions:
Features & Functions:
YC1891D-6 YC1891D-12 YC1891D-24 YC1891D-48
Number of meter positions 6 12 24 48
Accuracy 0.02%
Power Source YCS-101-250 YCS-101-600 YCS-101-1200 YCS-101-2500
Standard Meter SZ01A-K3Е
MSVT HJ200G-6 HJ200G-12 HJ200G-24 HJ200G-48
Scanning Head YCG-2-series
Voltage
Test voltage output(Phase-Neutral) 24V – 288V (or customized)
Power of the voltage output 100VA 250VA 500VA 1000VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd– 21st free programmable
Current
Test current output 1mA – 100A(or customized,Max.200A)
Power of the current output Max.150VA Max.350VA Max.750VA Max.1500VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd–21st free programmable
Phase angle
Range 0 -- 360°
Resolution 0.01°
Setting accuracy 0.1°
Frequency
Range 45Hz – 65Hz
Resolution 0.01Hz
Error display
Type of error display Red LED
Resolution of the error displays 8 digits
Other
Voltage Supply220V±10% or customized
50/60Hz±2Hz3x220/380V±10%
50/60Hz±2Hz
Ambient temperature -10°C -- +40°C
Relative humidity 35% -- 85%
2
Specifications:
Stationary Meter Test System
Accuracy 0.02%
Voltage
Test voltage output (Phase-Neutral) 3x(24V – 288V) (or customized )
Power of the voltage output Max.3x100VA Max.3x250VA Max.3x500VA Max.3x1000VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Current
Test current output 3x(1mA – 100A)
Power of the current output Max.3x150VA Max.3x350VA Max.3x750VA Max.3x1500VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Phase angle
Range 0 -- 360°
Resolution 0.01°
0.1°
Frequency
Range 45Hz – 65Hz
Resolution 0.01Hz
Error display
Type of error display Red LED
Resolution of the error displays 8 digits
Other
3x220/380V±10% (or customized)
50/60Hz±2Hz
Ambient temperature -10°C -- +40°C
Relative humidity 35% -- 85%
Power Source YCS-103-250 YCS-103-600 YCS-103-1200 YCS-103-2500
Standard Meter EMH SRS 400.3 / SZ03A-K8
Scanning Head YCG-S Series
YC1893D-6 YC1893D-12 YC1893D-24 YC1893D-48
Number of meter positions 6 12 24 48
Setting accuracy
Other
Voltage supply
3
Specifications:
Stationary Meter Test System