10
Automatic capacitor banks with static system. JAKI JK Power factor correction Static switching units (Three phase).

Static Switching Modules Unit

Embed Size (px)

DESCRIPTION

1. The static switching modules of the JK3PSZT series are the basic building block for the construction of static capacitor banks for power factor correction purposes. These capacitor banks use thyristors instead of the classic contactors for the connection of each large group of capacitors and they are ideal in installations where the leakage current suffers quick and large fluctuations (load changes in intervals that can range from split seconds to 8 or 10 seconds). 2. The static switching units of the JK3PSZT Series have been designed to connect and disconnect capacitors in milliseconds. They can be used to build capacitors with various steps, or for the individual compensation of a load that must be compensated instantly due to connection / disconnection deficiencies, for example, in welding units, cranes, lifts, etc.

Citation preview

Page 1: Static Switching Modules Unit

Automatic capacitor banks with static system.

JAKIJK

Power factor correctionStatic switching units (Three phase).

Page 2: Static Switching Modules Unit

Automatic capacitor banks with static system.

1JKwww.jaki.com.tw

Introduction

Selection table

2

3

JK3PSZTStatic switching units (three-phase)

4

JK3PSZT-XXXXX

Dimensions 5~7

2011 JAKI Co., All Rights Reserved.

Page 3: Static Switching Modules Unit

Automatic capacitor banks with static system.

2 JKwww.jaki.com.tw

Automatic capacitor banks with static system

Automatic capacitor banks with staticsystem. JK3PSZT-XXXXX

The all series capacitor banks with staticsystem have been designed for Powerfactor correction purposes innetworks with fluctuating loads.

The variations in power are relativelyfast (in milliseconds) so that the switchingoperations are carried out by thyristors,which are connected to a voltage controlboard, so that the connection anddisconnection of the capacitor is carriedout with a zero voltage difference.

Transients are prevented between theconnection and disconnection of steps,obtaining the immediate response to theload fluctuations.

Functions and advantages of capacitorbanks with a static system

The functions or advantages of thiscompensation system are as follows:

Immediate response to the compensationrequest. The response time of the Powerfactor correction can be of a single networkfrequency cycle, thus achieving an almostinstantaneous compensation.

Elimination of start-up transients produc-ed by the capacitor's connection. The conn-ection takes place when the voltage networkmatches that of the capacitor when it is par-tially or totally loaded.

The lack of transients in the connection allo-ws us to eliminate gaps, flicker and any otheralteration generated by the connection's tran-sient.

Limited switching operations

Lower wear of capacitors and switching elem-ents, due to the elimination of transients andthe total absence of mobile mechanical parts.This is how we can greatly increase the work-ing life of the unit, as compared to conventio-nal electromechanical contactor units.

Connection of a static capacitor bankStatic capacitor banks are usually connectedto the general switchboard or secondary swit-chboards in the case of large-scale installatio-ns.

Reg

ula

tio

n m

od

e

Time(s)Fig.1

STATIC REGULATION

CONVENTIONAL REGULATION

20ms 8s

2011 JAKI Co., All Rights Reserved.

Page 4: Static Switching Modules Unit

Automatic capacitor banks with static system.

3JKwww.jaki.com.tw

Product selection table

Equipment

10KVAR/240VAC20KVAR/440VAC24KVAR/480VAC22KVAR/525VAC29KVAR/600VAC

ScopeType

JK3PSZT-22050,22060,22080,22100JK3PSZT-48050,48060,48080,48100JK3PSZT-60050,60060,60080,60100

JK3PSZT-22125,22160JK3PSZT-48125,48160JK3PSZT-60125,48160

JK3PSZT-22180JK3PSZT-48180JK3PSZT-60180

JK3PSZT-22225,22250,22300JK3PSZT-48225,48250,48300JK3PSZT-60225,60250,60300

JK3PSZT-22350,22400JK3PSZT-48350,48400JK3PSZT-60350,60400

JK3PSZT-22035JK3PSZT-48035JK3PSZT-60035

15 to 30KVAR/240VAC29 to 58KVAR/440VAC35 to 70KVAR/480VAC31 to 63KVAR/525VAC41 to 83KVAR/600VAC

37 to 48KVAR/240VAC73 to 93KVAR/440VAC87 to 112KVAR/480VAC79 to 101KVAR/525VAC104 to 133KVAR/600VAC

54KVAR/240VAC105KVAR/440VAC126KVAR/480VAC114KVAR/525VAC150KVAR/600VAC

68 to 90KVAR/240VAC131 to 175KVAR/440VAC157 to 210KVAR/480VAC142 to 190KVAR/525VAC188 to 251KVAR/600VAC

105 to 120KVAR/240VAC204 to 234KVAR/440VAC245 to 280KVAR/480VAC222 to 253KVAR/525VAC292 to 334KVAR/600VAC

Photo

3.3kg

2

3

4

5

6

Weight

1

3.6kg

5kg

5.6kg

225A 16kg250A 17kg300A 18kg

18kg

2011 JAKI Co., All Rights Reserved.

Page 5: Static Switching Modules Unit

4 JKwww.jaki.com.tw

Automatic capacitor banks with static system.

4 JKwww.jaki.com.tw

JK3PSZT-XXXXXStatic switching units (three-phase)

Description

The static switching modules of theJK3PSZT series are the basic buildingblock for the construction of staticcap-acitor banks for power factor correctionpurposes.

These capacitor banks use thyristorsinstead of the classic contactors for theconnection of each large group of capa-citors and they are ideal in installationswhere the leakage current suffers quickand large fluctuations (load changes inintervals that can range from splitseconds to 8 or 10 seconds).

Application

The static switching units of theJK3PSZT Series have been designedto connect and disconnect capacitorsin milliseconds.

They can be used to build capacitorswith various steps, or for the individ-ual compensation of a load that mustbe compensated instantly due to con-nection / disconnection deficiencies,for example, in welding units, cranes,lifts, etc.

Features

Features

Protections

Ambient conditions

Construction features

Standards

Standard voltages

Frequency

Auxiliary voltage

Overload capacity

208~240, 380~480, 500~600VAC 10%±

47~63 Hz

220VAC 15%±

1.5 n during 1 minI

Bussmann or Hinoda

90℃

Fuses

du / dt

Thermostat

di / dt RC protection at 1000 V/ sμ

100 A/ s (L=12 H, not included, it must beμ μinstalled in series with the capacitor)

Maximum ambient temperature

Maximum temperature of thedissipator

50℃

80℃

Degree of protection

IEC6015-2, EN61000-6-4, EN61000-6-2

Automatic fan Heat sink 55 start, 45 stop℃ ℃

Input control signal AC control, 220VAC 15%. Contact control.±DC control, 12-24VDC.

IP00

2011 JAKI Co., All Rights Reserved.

Page 6: Static Switching Modules Unit

Automatic capacitor banks with static system.

5JKwww.jaki.com.tw

Dimensions

30mm

15

4m

m

142mm

5mm

22

0m

m

R S T

U V W

135mm

15

0m

m

142mm

P.1

30mm

FAN FAN

R S T

U V W

15

4m

m

142mm

5mm

24

3m

m

135mm

15

0m

m

142mm

P.2

2011 JAKI Co., All Rights Reserved.

Page 7: Static Switching Modules Unit

4 JKwww.jaki.com.tw

Automatic capacitor banks with static system.

6 JKwww.jaki.com.tw

Dimensions

40mm

141mm

30

5m

m

FAN

R S T

U V W

133mm

19

0m

m

17

2m

m

141mm

5mm

P.3

141 mm

20

0 m

m

40mm

141mm

36

5

mm

FAN

R S T

U V W

135mm

24

0m

m

P.4

2011 JAKI Co., All Rights Reserved.

Page 8: Static Switching Modules Unit

Automatic capacitor banks with static system.

7JKwww.jaki.com.tw

Dimensions

31

mm

21

0m

m

263mm

R S T

U V W

16

8m

m1

68

mm

INPUT

LOAD

242mm

6mm

40

0m

m

263mm

P.5

P.6

62 m

m2

44

mm

306mm

R S T

U V W

20

0m

m2

00

mm

INPUT

LOAD

288mm

6mm

52

7m

m

306mm

2011 JAKI Co., All Rights Reserved.

Page 9: Static Switching Modules Unit

4 JKwww.jaki.com.tw

Automatic capacitor banks with static system.

8 JKwww.jaki.com.tw

Functional block Diagram

R S T

U V W

Zero point inputcontroller.

Power supply.

Error signalindicates.

Power input

Load (capacitor)

2011 JAKI Co., All Rights Reserved.

Fuse Fuse Fuse

Fuse opencheck circuit.

55°C fan wor-king circuitand overtemperaturecheck.

On the heatsink temper-ature sensor.

Page 10: Static Switching Modules Unit

Automatic capacitor banks with static system.

9JKwww.jaki.com.tw

JAKI Enterprise Co., Ltd.No.11, Lane2 Rencih St.,Dali City, Taichung City41282 TaiwanTEL: +886-4-24915501FAX: +886-4-24954240www.jaki.com.tw

2011 JAKI Co., All Rights Reserved.