Page 2: standard & advanced phased array, tofD and real … GEKKO.pdfstandard & advanced phased array, tofD and real-time total focusing Method. ... (TCG, DAC, DGS)

UniqUe set of nDt techniqUesWith a 64-channel parallel architecture, GEKKO is the only flaw detector offering conventional UT, standard

PAUt, tofD and real-time total focusing Method (tfM).

coMPlete toolsetAll GEKKO techniques (UT, TOFD, PAUT, TFM) are available for conventional and phased-array probes as well as dual array probes (linear and matrix). Delay laws can be calculated onboard avoiding the need to import them from a Pc.

ReADy foR fielD insPectionGEKKO meets or exceeds the minimum instrumentation and software requirements specified in ASME, AWS, API, ASTM, ISO-EN standards for code compliant inspections while providing unique means of default characterization. GEKKO is also certified by CSWIP and PCN approved.

coMPAtible with AccessoRiesGeKKo uses iPeX connectors for phased-array Ut and leMo connectors for conventional Ut. with up to 3 encoders input, GEKKO offers compatibility with common and advanced scanning devices.

Page 3: standard & advanced phased array, tofD and real … GEKKO.pdfstandard & advanced phased array, tofD and real-time total focusing Method. ... (TCG, DAC, DGS)
Page 4: standard & advanced phased array, tofD and real … GEKKO.pdfstandard & advanced phased array, tofD and real-time total focusing Method. ... (TCG, DAC, DGS)
Page 5: standard & advanced phased array, tofD and real … GEKKO.pdfstandard & advanced phased array, tofD and real-time total focusing Method. ... (TCG, DAC, DGS)

echoDynAMic c-scAn tfM

A-scAn tfMtfM-scAn

Page 6: standard & advanced phased array, tofD and real … GEKKO.pdfstandard & advanced phased array, tofD and real-time total focusing Method. ... (TCG, DAC, DGS)
Page 7: standard & advanced phased array, tofD and real … GEKKO.pdfstandard & advanced phased array, tofD and real-time total focusing Method. ... (TCG, DAC, DGS)

generalL x W x H: 410mm x 284mm x 126mm 10.4‘’ high contrast resistiv e screen - resolution 1024x768 pxOperating temperature range: f rom -10°C to 45°C | 14°F to 113°F Weight: 6kg (without battery ) ; 0,480g /batteryStorage temperature range: -10°C to 60°C | 14°F to 140°F with battery IP66Operating time: 4h (hot swappable battery ) Shock resistance according to MIL-STD-810G

I-O1 IPEX connector f or phased-array (can be upgraded to 2 with splitter) 4 LEMO 00 connectors f or conv entional UT3 encoder inputs 1 external trigger3 USB 2.0 Acquisition f ile transf er through Ethernet

16 analog inputs

analysisCapture © sof tware with analy sis and reporting tools – Free v iewer Amplitude range: up to 800%A-Scan, B-Scan, C-Scan, D-Scan, Echody namic, Top v iew, Side v iew, 3D v iew Ov erlay part geometry : plate, cy linder, T or Y section, nozzleAnaly sis gates Ov erlay weld geometry Compatibility with CIVA analy sis and ENLIGHT Customizable inspection report

acquisitionHardware acquisition gates Max. data f low 150 MB/s on a 128Gb SSD (extensible up to 1 To)A-Scan/Peak data recording Inspection data f ile size: up to 10GbFMC recording Data transf er through EthernetAcquisition trigger on time, ev ent, encoder 800% amplitude range

pulsers64 phased-array channels*: 4 UT-TOFD channels**:Negativ e square pulse, width: 35ns to 1250ns Negativ e square pulse, width: 30ns to 1250nsVoltage: 12V – 100V with 1V step Voltage: 12V to 200V with 1V stepMax. PRF: up to 20kHz Max. PRF: up to 20kHz

real-time TFMReconstruction channels: up to 64 Max number of points of reconstructed image: up to 65kMax ref resh rate: up to 80f ps Sound paths: direct (L or S), indirect and conv erted modes

standard phased-arrayLinear scanning, sectorial scanning, compound scanning Linear, matrix, DLA and DMA probesMaximum activ e aperture: 64 channels Up to 6 probes | Up to 8 groups | Up to 2,048 delay -lawsPhased array computation delay laws on plate, cy linder, T & Y, nozzle CIVA f ueled phased-array calculatorFocusing mode: true depth, sound path, projection

wizardsCAD ov erlay and 3D v iew Scanner calibrationReal-time phased array calculator Amplitude calibration (TCG, DAC, DGS)Base-time calibration f or conv entional UT Probe design | Weld geometry designWedge calibration (angle, height, v elocity ) Amplitude balancingSpecimen v elocity calibration Part geometry with parametric shapes: plate, cy linder, T & Y, nozzle

digitizerDigitizing and real-time summation on 64 channels Resolution: 16bitsFIR f ilters Max. sampling f requency : 100 MHzReal-time av eraging up to x32 Digitizing depth up to 16k pointsRectif ied, RF, env elope A-scan range or delay max 65k points

receivers64 phased-array channels*: 4 UT-TOFD channels**:Input impedance: 50 Ω Input impedance: 50 ΩFrequency range: 0.4 to 20MHz Frequency range: 0.6 to 25MHzMax. input signal: 2Vpp | TCG – ACG – DGS calibration wizard | DGS Max. input signal: 2VppGain: up to 120dB (0.1dB step) TCG – DAC calibration wizard Cross-talk between two channels < 50 dB Gain: up to 120dB (0.1dB step)