INSTALLATION INSTRUCTIONS CRS-INST © Panduit Corp. 2014 www.panduit.com For instructions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp E-mail: [email protected] Phone: 866-405-6654 Rev. 04 Page 1 of 1 MALE DOVETAIL FEMALE DOVETAIL SLOT CABLE TIE SLOT CABLE TIE SLOT LATCH FEMALE DOVETAIL SLOT APPLICATION SURFACE MALE DOVETAIL LATCH RETAINING FACE CABLE RETAINING POST Figure 1 Figure 4 Figure 5 Figure 6 Figure 7 Figure 2 Figure 3 1) Secure bottom level of Stackable Cable Rack Spacer to the application surface, i.e. ladder rack rung with two standard cross-section Panduit Pan-Ty Cable Ties (Figures 1, 2, and 3). 2) Install cable or cable bundles into each of the cable retaining areas. 3) Secure cable to the cable retaining post with Panduit Pan-Ty Cable Ties, Belt-Ty In-Line Cable Ties, or Tak-Ty Hook and Loop Cable Ties up to 0.33" in width. 4) Installation of the next level of Stackable Cable Rack Spacers is accomplished by sliding the male dovetail into the female dovetail slot (Figures 4, 5, and 6). The latch(s) will lock the parts into position. To unlock these parts, use a screwdriver or a small tool to release latch(s) and slide in opposite direction. 5) Repeat steps 2, 3, and 4 until a maximum stack height is achieved. Panduit recommends a maximum stack height of five for the CRS6-X and CRS1-X. A maximum stack height of four is recommended for the CRS1-125-X and CRS4-125-X. Stackable Cable Rack Spacers are reversible to allow cable retaining posts to be alternated (Figure 7). CABLE TIE SLOT(S) FEMALE DOVETAIL(S) & LATCH(S) APPLICATION SURFACE LADDER RACK RUNG MALE DOVETAIL MALE DOVETAIL CABLE RETAINING POST MALE DOVETAIL FEMALE DOVETAIL SLOT CABLE TIE SLOT CABLE TIE SLOT LATCH FEMALE DOVETAIL SLOT APPLICATION SURFACE MALE DOVETAIL LATCH RETAINING FACE CABLE RETAINING POST DIRECTION OF MOTION FOR OPPOSITE ORIENTATION OF CABLE RETAINING POSTS LEVEL 1 LEVEL 2 DIRECTION OF MOTION FOR SAME ORIENTATION OF CABLE RETAINING POSTS BASE LEVEL CABLE RACK SPACER APPLICATION SURFACE- LADDER RACK RUNG CABLE RETAINING POST Stackable Cable Rack Spacers Part Numbers: CRS1-X, CRS1-125-X, CRS4-125-X, CRS6-X

Stackable Cable Rack Spacers - Panduit

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Stackable Cable Rack Spacers - Panduit

INSTALLATION INSTRUCTIONS CRS-INST© Panduit Corp. 2014

www.panduit.com

For instructions in Local Languagesand Technical Support:

www.panduit.com/resources/install_maintain.asp

E-mail:[email protected]

Phone:866-405-6654

Rev. 04Page 1 of 1

MALE DOVETAIL

FEMALE DOVETAIL SLOT

CABLE TIE SLOTCABLE TIE SLOT

LATCH

FEMALE DOVETAIL SLOT

APPLICATIONSURFACE

MALE DOVETAIL

LATCH RETAINING FACE

CABLE RETAINING POST

Figure 1

Figure 4 Figure 5 Figure 6 Figure 7

Figure 2 Figure 3

1) Secure bottom level of Stackable Cable Rack Spacer to the application surface, i.e. ladder rackrung with two standard cross-section Panduit Pan-Ty Cable Ties (Figures 1, 2, and 3).

2) Install cable or cable bundles into each of the cable retaining areas.

3) Secure cable to the cable retaining post with Panduit Pan-Ty Cable Ties, Belt-Ty In-LineCable Ties, or Tak-Ty Hook and Loop Cable Ties up to 0.33" in width.

4) Installation of the next level of Stackable Cable Rack Spacers is accomplished by sliding themale dovetail into the female dovetail slot (Figures 4, 5, and 6). The latch(s) will lock the partsinto position. To unlock these parts, use a screwdriver or a small tool to release latch(s) andslide in opposite direction.

5) Repeat steps 2, 3, and 4 until a maximum stack height is achieved. Panduit recommends amaximum stack height of five for the CRS6-X and CRS1-X. A maximum stack height of four isrecommended for the CRS1-125-X and CRS4-125-X. Stackable Cable Rack Spacers arereversible to allow cable retaining posts to be alternated (Figure 7).

CABLE TIESLOT(S)

FEMALE DOVETAIL(S) &

LATCH(S)APPLICATION SURFACE LADDER RACK RUNG

MALE DOVETAILMALE DOVETAIL

CABLE RETAINING POST

MALE DOVETAIL

FEMALE DOVETAIL SLOT CABLE TIE SLOT

CABLE TIE SLOT LATCH

FEMALE DOVETAIL SLOT

APPLICATIONSURFACE

MALE DOVETAIL

LATCH RETAINING FACE

CABLE RETAINING POST

DIRECTION OF MOTION FOR OPPOSITE ORIENTATION OF CABLE RETAINING POSTS

LEVEL 1

LEVEL 2

DIRECTION OF MOTION FOR SAME ORIENTATION OF CABLE RETAINING POSTS

BASE LEVELCABLE RACK SPACER

APPLICATION SURFACE- LADDER RACK RUNG

CABLE RETAINING POST

Stackable Cable Rack SpacersPart Numbers: CRS1-X, CRS1-125-X, CRS4-125-X, CRS6-X

Page 2: Stackable Cable Rack Spacers - Panduit

INSTALLATION INSTRUCTIONS CRS-INST© Panduit Corp. 2014

www.panduit.com

For instructions in Local Languagesand Technical Support:

www.panduit.com/resources/install_maintain.asp

E-mail:[email protected]

Phone:866-405-6654

Rev. 04Page 1 of 1

MALE DOVETAIL

FEMALE DOVETAIL SLOT

CABLE TIE SLOTCABLE TIE SLOT

LATCH

FEMALE DOVETAIL SLOT

APPLICATIONSURFACE

MALE DOVETAIL

LATCH RETAINING FACE

CABLE RETAINING POST

Figure 1

Figure 4 Figure 5 Figure 6 Figure 7

Figure 2 Figure 3

1) Secure bottom level of Stackable Cable Rack Spacer to the application surface, i.e. ladder rackrung with two standard cross-section Panduit Pan-Ty Cable Ties (Figures 1, 2, and 3).

2) Install cable or cable bundles into each of the cable retaining areas.

3) Secure cable to the cable retaining post with Panduit Pan-Ty Cable Ties, Belt-Ty In-LineCable Ties, or Tak-Ty Hook and Loop Cable Ties up to 0.33" in width.

4) Installation of the next level of Stackable Cable Rack Spacers is accomplished by sliding themale dovetail into the female dovetail slot (Figures 4, 5, and 6). The latch(s) will lock the partsinto position. To unlock these parts, use a screwdriver or a small tool to release latch(s) andslide in opposite direction.

5) Repeat steps 2, 3, and 4 until a maximum stack height is achieved. Panduit recommends amaximum stack height of five for the CRS6-X and CRS1-X. A maximum stack height of four isrecommended for the CRS1-125-X and CRS4-125-X. Stackable Cable Rack Spacers arereversible to allow cable retaining posts to be alternated (Figure 7).

CABLE TIESLOT(S)

FEMALE DOVETAIL(S) &

LATCH(S)APPLICATION SURFACE LADDER RACK RUNG

MALE DOVETAILMALE DOVETAIL

CABLE RETAINING POST

MALE DOVETAIL

FEMALE DOVETAIL SLOT CABLE TIE SLOT

CABLE TIE SLOT LATCH

FEMALE DOVETAIL SLOT

APPLICATIONSURFACE

MALE DOVETAIL

LATCH RETAINING FACE

CABLE RETAINING POST

DIRECTION OF MOTION FOR OPPOSITE ORIENTATION OF CABLE RETAINING POSTS

LEVEL 1

LEVEL 2

DIRECTION OF MOTION FOR SAME ORIENTATION OF CABLE RETAINING POSTS

BASE LEVELCABLE RACK SPACER

APPLICATION SURFACE- LADDER RACK RUNG

CABLE RETAINING POST

Stackable Cable Rack SpacersPart Numbers: CRS1-X, CRS1-125-X, CRS4-125-X, CRS6-X