22
Microwave SRAL XD PDH Radio Access & Mobile Applications

Sra l Xd_mw Siemens Pdh Lowcap

Embed Size (px)

Citation preview

Microwave

SRAL XD PDH Radio Access & Mobile Applications

SRAL XD Page 2

SRAL XDSystem Configurations

(1+0)

2x(1+0)

(1+1) Hot Standby

(1+1) Freq. / Pol. Diversity

Add / Drop Repeater

BSC

BTS

BTS

BTSBTS

MSC

CoreNetwork

BSC

BTSBTS

BTS

BTS

BTS

BTS

BTS

BSC

star multi-drop

ring

MSC

Suitable for every network topology

SRAL XD Page 3

Access Radio Catalogue – EvolutionSRAL XD – Main Features (I)

Split architecture

Frequency bands:– 7 ÷ 38 GHz traditional frequency

bands– 28, 32, 52 GHz new bands

Payload interface:– 2/16xE1– E3– 10/100 BaseT (LAN bridging)

Additional Features:– High / Normal Density operation (14 / 28 2MHz for 16xE1 capacity)– E1 Cross Connect capability

SRAL XD Page 4

SRAL XDArchitecture Change

Result: 1 UH IDU for Protected Configuration (best in class compactness)

AggregatedAggregatedBaseband SignalBaseband Signal

nxE1Base Band

nxE1Base Band

320 / 70 MHz IF320 / 70 MHz IFSRA LSRA L

SRAL XDSRAL XD

ModemModem

SRAL XD Page 5

SRAL XDArchitecture

IDU Basic Functions:

System interface to external world

Baseband digital signal processing

IDU-ODU cable interface management

System supervision and configuration Mngt

Equipment power supply

ODU Basic Functions:

Modulation of baseband signal

Up-conversion to RF signal

Down-conversion of receivedRF signal

Demodulation to baseband signal

ODU supervision and config. Mngt

IDU-ODU cable interface Mngt

1+0 Terminals

AggregatedBaseband Signal

1+0 1+1 Terminals

AggregatedBaseband Signal

Access Unit

Controller Unit

BB#1Access Unit

Controller Unit BB#2

BB#1Access Unit

Controller Unit BB#2

BB#1

Add and Drop Terminals

SRAL XD Page 6

SRAL XDProduct line suite

Normal Density Normal and High Density

IDU Single Board Basic configurations

IDU Plug-in Full set of configurations

MinIDU Integrated into BS/NB

General purposeapplication

Siemens BTS/NBapplication

SRAL XD Page 7

SRAL XDODU ND

• Modulation format: 4 CPM (Normal Density)

• RF bands: 15 38 GHz28 GHz New Entry7 13 GHz tbd

• System performance in line with SRA L (1 dB better)

• Attenuation range: 24 dB up to 23 GHz20 dB 26 38 GHz

• ATPCdriven by Rx Power and BER

• Improved RF tunability38 G: 4 ext. (6)26 G: 4 ext. (6)23 G: 2 ext. (4)18 G: 4 ext. (10)7 15G: in line with SRA L

• Dimensions: 230x230x110 mm

• Weight: 4.3 Kg

• Fully compatible withSRA L antennas, supporting frame, cable

• No replacement of SRA L ODU (modem on board)

SRAL XD Page 8

SRAL XDODU HD/HP

• Modulation format:16 TCM (High Density)(SW selectable) 4 QAM (High Performance)

• RF bands: 7 38 GHz28 GHz New Entry13 GHz tbd

• System gain 16 TCM: almost in line with SRA L(easy migration from 8xE1 SRA L to 16xE1 HD by reuse of same antennas) 4 QAM: 5 dB more than 16 TCM(to offer as High Power solution)

• Attenuation range: 20 dB

• ATPCdriven by Rx Power and BER

• Improved RF tunability (as of ODU ND)

• Dimensions: 270x270x150 mm

• Weight: 7.5 Kg

• Fully compatible withSRA L antennas, supporting frame, cable

• No replacement of SRA L ODU

SRAL XD Page 9

SRAL XDIDU Single Board (1) Monolithic Unit Concept

– No plug-in cards– IDU as a single “Least Replaceable

Unit”– No in-field hardware upgrade

Available in 4 hardware main versions:– IDU SB up to 8E1 (1+0)– IDU SB up to 16E1 (1+0)– IDU SB up to 8E1 (1+1) HSBy– IDU SB up to 16E1 (1+1) HSBy

System configuration constraints– (1+1) HSBy w/ ODU redundancy

only– No (1+1) Freq. Diversity– No 2x(1+0) / AD Repeater

Dimensions: 1U high even for (1+1) and 2x(1+0)

Power supply -48V 20%

Tributary interface options:– Sub-D 50c 120 Ω– µcoax 75 Ω– Lemo 120 Ω

1U

SRAL XD Page 10

SRAL XDIDU Single Board (2) SW fully downloadable (ODU included)

Features enabled via SW licence fee:– Capacity– Configuration– RF channels density (Normal / High)

Feature upgrade via SW licence fee (within HW constraint)

Memory key with system settings (for IDU fast replacement)

Built-in Qx-Adapter + Alarm Unit + Double V.11 Card SRA L like functionality:– Ethernet i/f towards NMS– Alarm collection / restitution– 64K V.11 NMS channel (Dext) / User Channel

Voice Service Channel via VoIP (NetMeeting or IP phone)

Standard TCP / IP stack for NMS traffic (easier interworking with DCN routers)

SRA L like TCP / IP stack for interworking with SRA L equipment

SRAL XD Page 11

SRAL XDIDU Plug-in SRA L-like Concept

– Plug-in cards– Hot replacement of faulty card– In-field HW upgrade to (1+1)

Available in 2 hardware main versions (like SRA L Universal):– IDU PI up to 16E1 (1+0)– IDU PI up to 16E1 (1+1)/Add-Drop

Full set of system configurations– (1+0)– (1+1) HSBy – (1+1) Freq. Diversity– 2x(1+0) / AD Repeater

2M level Cross Connect functionality (no need for external Digital Distribution Frame)

Dimensions: 1U high even for (1+1) and 2x(1+0)

Power supply -48V 20%

Tributary interface options:– Sub-D 50c 120/75 Ω– µcoax 75 Ω– Lemo 120 Ω

1U

SRAL XD Page 12

SRAL XDIDU Plug-in (2)

SW fully downloadable (ODU included)

Features enabled via SW licence fee:– Capacity– Configuration– RF channels density (Normal / High)

Feature upgrade via SW licence fee (within HW constraint)

Memory key with system settings

Built-in Qx-Adapter + Alarm Unit + Double V.11 Card SRA L like functionality:– Ethernet i/f towards NMS– Alarm collection / restitution– 2x64K V.11 NMS channel (Dext) / User Channel

Voice Service Channel via VoIP (NetMeeting or IP phone)

Standard TCP / IP stack for NMS traffic (easier interworking with DCN routers)

SRA L like TCP / IP stack for interworking with SRA L equipment

SRAL XD Page 13

SRAL XDMinIDU

Tailored on Siemens BTS/NB– Plugged into Iub/Abis sockets– Almost no installation material required

(PS cable only)– IDU as a single “Least Replaceable

Unit”

Available in 2 hardware versions:– A) MinIDU up to 8E1 (1+0)– B) MinIDU up to 16E1 (1+1)/ Add-Drop

External traffic collection (co-location)– 2E1 in version A)– 8E1 in version B)

Full set of system configurations– (1+0)– (1+1) HSBy – (1+1) Freq. Diversity– 2x(1+0) / AD Repeater

2M level Cross Connect functionality

SRAL XD Page 15

SRAL XD Supporting Frame for Remote Mounting

A new supporting frame version replaces the present one used for remote mountingremote mounting of ODUs in (1+1) Hot (1+1) Hot Stand ByStand By (Balanced and Unbalanced)

This Supporting Frame is derived from thederived from the new new ssupporting upporting fframe for integrated mountingrame for integrated mounting. It has the same structure with, in addition, the proper material for pole or wall mounting. In this case the waveguide is still necessary.

Available frequency bands: 15,15, 18,18, 23,23, 26,26, 38 GHz38 GHz

As it concerns 7,8,13 GHz the present design As it concerns 7,8,13 GHz the present design of supporting frame remains unchanged.of supporting frame remains unchanged.

SRAL XD Page 16

SRA L Catalogue updateSupporting Frame for Integrated Mounting

As an alternative to present supporting frame for remote mounting, this new version is suitable for integrated mountingintegrated mounting of ODUs in (1+1) (1+1) Hot Stand ByHot Stand By configuration (Balanced and Unbalanced)

No need for waveguide

The result of this type of mounting is a compact structurecompact structure, that allows to hide the ODUs behind the antenna, with a minimum environmental impactminimum environmental impact.

This solution is available for 15,15, 18,18, 23,23, 26,26, 38 GHz 38 GHz RFRF bands bands.

It is suitable with SRA L antennas antennas withwith diameter 30, 60, 80 cm.diameter 30, 60, 80 cm.

SRAL XD Page 20

SRAL XDSystem Gain – Comparison

85,0

90,0

95,0

100,0

105,0

110,0

115,0

38G

Hz

28G

Hz

26G

Hz

23G

Hz

18G

Hz

15G

Hz

13G

Hz

8G

Hz

7G

Hz

Typical System Gain (BER=10-3)

SRA L 16xE1(4 CPM)

SRAL XD 16xE1 (4CPM)

SRAL XD 16xE1 (4QAM)

SRAL XD 16xE1 (16QAM)

SRAL XD Page 21

SRAL XD System Performances (16xE1 typical values)

Modulation

Tx Power (dBm)

RSL @ 10-3 (dBm)

Sys. Gain @ 10-3

-83.5 -83 -82 -81

13 GHz 18 GHz 23 GHz 38 GHz

4 CPM 4 CPM 4 CPM 4 CPM

20 18 18 17

103.5 101 100 98

Modulation

Tx Power (dBm)

RSL @ 10-3 (dBm)

Sys. Gain @ 10-3

18 GHz

-85.5

4 QAM

24

109.5

-85

16 TCM

19

104

-84

4 QAM

20

104

-83.5

16 TCM

15

98.5

38 GHz

-82.5

4 QAM

17

99.5

-82

16 TCM

12

94

23 GHz

ODU ND

ODU HD/HP

SRAL XD Page 22

SRAL XDIDU Families - Summary

1. Features are enabled via SW license fee2. Choice among a set of different tributary interfaces. No choice on MinIDU3. High Density option is applicable to 8E1 and 16E1 only

2E1

4E1

8E1

16E

1

(1+

0)

(1+

1)

HS

By

(1+

1) F

D

2x(1

+0

)/A

D R

ep

IDU SB up to 8E1 (1+1) HSByIDU SB up to 16E1 (1+1) HSByIDU PI up to 16E1 (1+0)IDU PI up to 16E1 (1+1)/ Add-DropMinIDU up to 8E1 (1+0)MinIDU up to 16E1 (1+1)/ Add-Drop

IDU SB up to 8E1 (1+0)IDU SB up to 16E1 (1+0)

No

rmal

D

ens

ity

Hig

h

Den

sit

y

Sin

gle

Bo

ard

Plu

g-i

nM

inID

U

SRAL XD Page 23

Same management system (NetViewer)

TMN compatibility. Same DCN already installed can be re-used. No need for external devices to connect SRAL XD TMN I/F to SRA L TMN I/F.

Same antennas and supporting frames of SRA L (identichal mechanical interfaces):common inventory

Same IDU/ODU cable and connection kits:common inventory

16 TCM system gain in line with SRA L: easy migration from 8xE1 SRA L to 16xE1 HD (same RF band occupancy) without need to increase antenna diameter

ODU ND is on-air compatible with SRA L 16xE1 (4CPM modulation)asymmetrical links are possible, but only with SRA L IDU Universal

SRAL XD Continuity with SRA L Product Line

SRAL XD Page 24

Reduced need for indoor room

Reduced power consumption (15 W lower in 1+1 config.)

High Density option

High Performance option (i. e. high System Gain)

Improved RF tunability

Increased segmentation of product family

Reduced DCN cost• Integrated LAN interface towards NMS (no need for DualQ-Adapter)• standard TCP / IP stack for direct interworking with routers

Improved system reliability

State of the art technology

SRAL XD Benefits compared to SRA L

SRAL XD Page 25

SRA L Family RoadmapCommercial availability

Now Available1Q 2Q

2003

SVR 1.4.2SVR 1.4.2S

SVR 1.4.0 F23, 26, 38 GHz

Fully Outdoor

Field Trials

58 GHz

3Q

58 GHz

Mass Production

4Q

SRA L

20041Q

SRAL XD

SRAL XD Page 26

SRAL XDProduct Line Roadmap (as of 01/06/03)

4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7ODU ND

Phase-in

IDU Plug-in

IDU Single Board

MinIDU

nxE1

SVR 3.4

SVR 4.2

SVR 6.1

nxT1

nxE1

nxE1

2003 2004

SVR 3.3

ODU HD/HP

Phase-in

SVR 4.3

Customer delivery can start now

SVR 3.2

SVR 4.4

38 23 26 2815 18

7 3818 28 2623

8