W SOUTH ST
W LENOIR STS D
AWSO
N ST
W CABARRUS ST
S WES
T ST
W DAVIE ST
S SAU
NDER
S ST
S HAR
RING
TON
ST
FOWLE ST DOROTHEA DR
COMM
ERCE
PL
S HAR
RING
TON
ST
Zoning:CAC:
Drainage Basin:Acreage:Sq. Ft .:
DX-5-ULCentralRocky Branch0.74103,250
0 600300 Feet
Planner:Phone:
Applicant:Phone:
Justin Rametta(919) 996-2665David Boyette(919) 866-4804
¯522 S HARRINGTON STREETSR-90-2016
!
WM
EIP
2QN
5QN
2QN
2QN
FF
=320.61'
BFP
GM
GV
WV
GM
24UA
26UA
20UA
FF=315.71'
FF
=315.56'
GM
12LI
6LI
16LI
20LI
FF=316.28'
15"DIP
FF=316.33'
3UA
3UA
2UA
FF=316.26'
20FG
14FG
22FG
12UA
7UA
6UA
6UA
6UA
4AR
3AR
3FG
3AR
2CC
3LI
3UA
8"CLAY
8"C
LA
Y
6
"
C
L
A
Y
8"C
LA
Y
8"C
LA
Y
8"CLAY
8"C
LA
Y
8"CLA
Y
8"D
IP
6" V
CP
RIM=312.96'
IN=310.26'
OUT=310.26'
RIM=313.70'
IN(N)=308.90'
IN(NE)=309.30'
OUT=307.65'
RIM=304.01'
IN(N)=298.31'
IN(E)=298.81'
OUT=298.29'
RIM=297.49'
IN=292.04'
OUT=291.99'
RIM=302.92'
IN(N)=297.77'
IN(W)=297.47'
OUT=297.42'
RIM=316.52'
IN=309.22'
IN=299.22'
OUT=299.02'
RIM=323.13'
OUT=317.93'
5QN
2TREE(S)
TOC=315.98'
OUT=312.53'
15"D
IP
2UA
1 STORY
WOOD
BUILDING
1 STORY
WOOD
BUILDING
1 STORY
BRICK
BUILDING
8" BLOCK WALL
GRAVEL
GRAVEL
ASPHALT
ASPHALT
AWNING
AWNING
BUILDING
OVERHANG
BUILDING
OVERHANG
4" BRICK
WALL
DE
CK
A/C UNIT
FUEL TANK
CHICKEN
COUP
8" B
LO
CK
W
ALL
HED
GER
OW
OLD WELL
RWM
EIP
EMON
EIP BENT
RWM
EIR
RWM
EIP
EIP
8" BLOC
K WALL
(301.1LF
)
(243.9LF
)
WM
S. W
ES
T S
TR
EE
T
66' P
UB
LIC
R
/W
W. LENOIR STREET
VARIABLE WIDTH PUBLIC R/W
S. H
AR
RIN
GT
ON
S
TR
EE
T
66' P
UB
LIC
R
/W
3
0
5
.
5
6
'
3
0
4
.
2
8
'
3
1
9
.
6
9
'
314.4'
314.5'
3
1
3
.
2
'
3
1
4
.
3
'
N/F
STAR MASS
COMPANY, INC.
D.B. 1623, PG. 603
PIN 1703561603
N/F
523 S. WEST
STREET, LLC.
D.B. 9539, PG. 94
PIN 1703560627
N/F
FAIRWEATHER
PROPERTIES, LLC.
D.B. 9539, PG. 103
PIN 1703560721
N/F
514 HARRINGTON
STREET, LLC.
D.B. 9539, PG. 98
PIN 1703561708
N/F
SHIMMERING
OAK, LLC.
D.B. 13779, PG. 1491
PIN 1703561702
10' CLF
LOADING DOCK
N87°40'49"W 105.22'
CENTERLINE OF WIRE
N02°27'14"E 108.60'
N02°27'14"E 25.72'
N87°40'49"W 105.22'
N02°27'14"E 34.61'
N87°40'49"W 105.22'
N02°27'14"E 38.79'
N87°40'49"W 105.22'
N02°27'14"E 52.21'
N02°27'14"E 52.21'
N88°36'16"E 210.92'
N87°40'49"W 105.22'
N87°40'49"W 105.22'
RRS
18.28'
N02°27'14"E
52.21'
DUKE ENERGY EASEMENT
DB. 13879, PG. 1535
"TRACT 2"
16.01'
S02°47'10"W 33.24'
DUKE ENERGY EASEMENT
DB. 13879, PG. 1535
"TRACT 1"
AWNING
6' CLF
EIP
N/F
STAR MASS
COMPANY, INC.
D.B. 13874, PG. 915
PIN 1703560597
N/F
STAR MASS
COMPANY, INC.
D.B. 1623, PG. 603
PIN 1703560527
6AR
POWER POLE
AD
JA
CE
NT
R/W
AD
JA
CE
NT
R/W
AS
PH
ALT
V
AR
IE
S
ASPHALT VAR
IES
ASPHALT VARIES
6" C
IP
6" C
IP
4QR
4TREE
S88°36'16"W
N87°54'51"W 318.17'
NC DOT R/W EASMENT
(D.B. 13845, PG. 1905)
(D.B. 2963, PG. 662)
N/F
PROGRESS ENERGY
CAROLINAS, INC.
D.B. 13845, PG. 1905
PIN 1703563723
4QR
4QR
4QR
6" V
CP
TOC=315.95'
IN(E)=311.94'
IN(W)=311.65'
OUT=311.25'
TOC=296.53'
IN=293.21'
OUT=293.12'
RIM=315.76'
OUT=312.28'
15"RCP
15"RCP
WM
8" CIP
8" DIP
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16058
421 FAYETTEVILLE ST, STE 400
RALEIGH, NC 27601
T 919.380.8750
Client:
Vicinity map:
Issued for:
Title:
Sheet:Project number:
Date:
Drawn by:
Approved by:
Project:
522
S. HARRINGTON
STREET
Date Description
ADMINISTRATIVE SITE
REVIEW
No.
Seal:
GREYMONT DEVELOPMENT LLC
8705 CATAMARAN DRIVE
RALEIGH , NC 27615
T: 919.656.6077
PRELIMINARY - DO NOT
USE FOR CONSTRUCTION
W. CABARRUS ST.
NORTH
S. W
ES
T S
T.
W. SOUTH ST.
R
A
I
L
R
O
A
D
S. H
AR
RIN
GT
ON
S
T.
W. LEN
OIR
ST.
SITE
12.15.16 CITY COMMENTS1
05.25.17 CITY COMMENTS2
07.11.17 CITY COMMENTS3
10.13.17 CITY COMMENTS4
0 10 20 40
1"= 20'SCALE:
NORTH
FF=267.18'
SURVEY CONTROL POINT
EXISTING IRON PIPE
EXISTING CONCRETE MONUMENT
STORM DRAIN MANHOLE
SANITARY SEWER MANHOLE
SANITARY SEWER CLEANOUT
HYDRANT
WATER VALVE
WATER METER
WATER MANHOLE
WELL
GAS VALVE
GAS METER
TELEPHONE MANHOLE
TELEPHONE PEDESTAL
TV MANHOLE
TV PEDESTAL
ELECTRIC MANHOLE
ELECTRIC BOX
UTILITY POLE
GUY WIRE
LIGHT POLE
TRAFFIC SIGNAL BOX
BOLLARD
SIGN
FINISHED FLOOR ELEVATION
UNDERGROUND TELEPHONE LINE
UNDERGROUND FIBER OPTIC LINE
UNDERGROUND GAS LINE
UNDERGROUND ELECTRIC LINE
UNDERGROUND WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
OVERHEAD WIRES
UNIDENTIFIED LINE
EIP
ECM
DIP
PVC
HDPE
RCP
CMP
CB
T
FO
G
E
W
SS
OHW
U
DUCTILE IRON PIPE
POLYVINYL CHLORIDE PIPE
HIGH-DENSITY POLYETHYLENE PIPE
REINFORCED CONCRETE PIPE
CORRUGATED METAL PIPE
CATCH BASIN
CATV
TPED
GM
WM
TRAFFIC SIGNAL POST
GV
ELECTRIC METER
MONITORING WELL
UNKNOWN DESTINATION
FIBER OPTIC WITNESS POST
BORING LOCATION
SANITARY FORCEMAIN VALVE
STORM DRAIN CURB INLET
COMPUTED POINT
FIBER OPTIC BOX
GUY POLE
MANHOLE
DECIDUOUS TREE
EVERGREEN TREE
BUSH
WIRE FENCE
CHAIN LINK FENCE
CONCRETE SURFACE
WV
FOWP
EM
MW
BOR
IO
LI
AMERICAN HOLLY
CREPE MYRTLE
PO
PT
QR
EASTERN SYCAMORE
LOBLOLLY PINE
RED OAK
EXAMPLE: 10QR = 10" RED OAK
MG SOUTHERN MAGNOLIA
JV EASTERN RED CEDAR
SURVEY TREE LEGEND:
SURVEY LEGEND:
Q
:\2
01
6\C
16
05
8 - 5
22
S
. H
arrin
gto
n S
tre
et\D
WG
S\1
- D
esig
n\S
he
ets\C
16
05
8-C
1.0
0-E
xistin
g C
on
ditio
ns.d
wg
O
ct 1
3, 2
01
7 - 1
1:0
2a
m
EXISTING
CONDITIONS PLAN
C1.00
C16058
11.04.2016
SP/TSH
DMB
GENERAL NOTES
1. THIS SURVEY MAP IS INTENDED TO REPRESENT THE
EXISTING CONDITIONS/TOPOGRAPHY ON A PORTION OF
THE PROPERTIES SHOWN HEREON, AND IS NOT A
BOUNDARY SURVEY. THIS SURVEY WAS PERFORMED
WITHOUT THE BENEFIT OF A TITLE REPORT AND
THEREFORE ALL ENCUMBRANCES UPON THE PROPERTY
MAY NOT BE SHOWN.
2. THE PROPERTY LINES SHOWN HEREON HAVE BEEN
CONFIRMED FROM A PARTIAL SURVEY BY STEWART INC.
PROPERTY LINES SHOWN TAKEN FROM REFERENCES
LISTED HEREON.
3. HORIZONTAL DATUM IS NAD 83 (2011) AND VERTICAL
DATUM IS NAVD88. BASED ON GPS METHODS USING
REAL-TIME KINEMATIC SOLUTIONS FOR THE SURVEY
CONTROL POINTS SHOWN HEREON AND TIED TO NORTH
CAROLINA GEODETIC SURVEY MONUMENT "MURRAY".
"MURRAY"
N 747347.86'
E 2112922.52'
EL 215.7'
4. THIS DRAWING DOES NOT CONFORM TO N.C. GS47-30
AND THEREFORE IS NOT FOR RECORDATION.
5. UTILITIES SHOWN HEREON ARE BASED ON
ABOVE-GROUND VISIBLE EVIDENCE AND UTILITY
DESIGNATION/MARKING SERVICES PERFORMED BY
STEWART INC. AS A PART OF THIS SURVEY.
CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF
ALL UTILITIES BEFORE COMMENCING CONSTRUCTION.
6. TREES SHOWN HEREON MAY NOT REPRESENT ALL
VEGETATION ON THE SUBJECT PROPERTY.
7. THE SUBJECT PROPERTY IS ZONED "DX-5-UL" (PER WAKE
COUNTY IMAPS).
8. THE SUBJECT PROPERTY LIES IN ZONES X (AREA
DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE
AND FUTURE CONDITIONS 1% ANNUAL CHANCE
FLOODPLAIN). BASED ON THE FLOOD INSURANCE RATE
MAP COMMUNITY MAP NUMBER 3720170300J DATED
05/02/06. FLOOD HAZARD LINES SHOWN HEREON ARE
FROM NCFLOODMAPS.COM.
9. TRANSMISSION LINE ALONG WEST ST. IS SUBJECT TO A
FRANCHISE AGREEMENT BETWEEN DUKE ENERGY AND
THE CITY OF RALEIGH. CONTACT DUKE ASSET
PROTECTION DEPARTMENT FOR MORE INFORMATION.
STORMWATER
MANAGEMENT
PROPOSED 5-STORY
MIXED USE BUILDING w/
2-LEVEL PARKING
LOWER LEVEL - S. WEST
STREET ACCESS
UPPER LEVEL - S. HARRINGTON
STREET ACCESS
S. W
ES
T S
TR
EE
T
66' P
UB
LIC
R
/W
W. LENOIR STREET
VARIABLE WIDTH PUBLIC R/W
S. H
AR
RIN
GT
ON
S
TR
EE
T
66' P
UB
LIC
R
/W
CENTERLINE OF WIRE
DUKE ENERGY EASEMENT
DB. 13879, PG. 1535
"TRACT 2"
DUKE ENERGY EASEMENT
DB. 13879, PG. 1535
"TRACT 1"
POWER POLE
12.0'
12.0'
6.0'
6.0'
R 23'
24.0'
21.0'
66.0'
(EXISTING R/W)
4.0'
66.0'
(EXISTING R/W)
103.6'
(E
XIS
TIN
G R
/W
V
AR
IE
S)
83.3'
(E
XIS
TIN
G R
/W
V
AR
IE
S)
4.0'
4.0'
39.7'
(A
SP
HA
LT
V
AR
IE
S)
41.3' (A
SP
HA
LT
V
AR
IE
S)
34.2'
(AS
PH
ALT
VA
RIE
S)
33.5'
(ASPHALT VARIES)
40.0'
(ASPHALT VARIES)
53.0'
(ASPHALT VARIES)
10.0'
DUKE ENERGY
TRANSMISSION LINE
OFFSET
MAXIMUM BUILD-TO
LINE (20')
MAXIMUM
BUILD-TO LINE
MINIMUM REAR LOT
LINE BUILDING
SETBACK
RETAINING WALL
TRANSFORMER LOCATION
AREA OF PARALLEL
PARKING
STREET TREE IN
6'X4' TREE GRATE
(40' O.C.)
OPEN SPACE (TYP)
RETAINING WALL
STREET TREE IN
6'X4' TREE GRATE
(40' O.C.)
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
OUTDOOR AMENITY 3803 SF
EX. ELECTRICAL
VAULTS
BIKE RACK (TYP)
DUKE ENERGY
TRANSMISSION
LINE OFFSET
TRASH ROOM WITH
COMPACTOR
13.25'X11.50'
LOWER LEVEL PARKING
LAYOUT SHOWN
AMENITY AREA ACCESS
FROM PUBLIC R/W
NEW CURB
RAMP
3.5' EASEMENT FOR
SIDEWALK OUTSIDE
OF R/W
PROPOSED GATE TO
ALLOW ACCESS TO
GAS METERS
PROPOSED GATE TO
ALLOW ACCESS TO
GAS METERS
2500
4500
FLUSH ADA ACCESS
TO PUBLIC R/W
CONCRETE STAIRS
PRIMARY RETAIL ACCESS
RETAINING WALL
BIKE RACKS (TYP)
OUTDOOR AMENITY 1,721 SF
TABLE & CHAIRS (TYP.)
20.0'
8' BENCH (TYP.)
PLAZA AND
SEATING AREA
20.0'
20.0'
EASEMENT EXTENDS ACROSS
EXTENT OF PROPERTY LINE.
SEE NOTE #2.
CONCRETE
PAVERS
24.0'
9.0'
(TYP)
22.0'
9.0'
18.0'
(T
YP
)
S. H
AR
RIN
GT
ON
S
TR
EE
T
23.0'
8.0'
9.0'
5.0'
W
W
W
W
CLEAR STORY
RETAIL SPACE
2500
4500
RESIDENTIAL -
UPPER LEVEL
ONLY
22.7'
24.8'
9.0'
(TYP)
18.0'
(T
YP
)
23.0'
22.0'
S. W
ES
T S
TR
EE
T
WW
WW
CLEAR STORY
RETAIL SPACE
2500
4500
TRANSFORMER LOCATION
10'-4" CLEAR
HEIGHT
20.0
390' LE
FT
T
UR
N S
IG
HT
D
IS
TA
NC
E (35 M
PH
)
390' LE
FT
T
UR
N S
IG
HT
D
IS
TA
NC
E (35 M
PH
)
340' R
IG
HT
T
UR
N S
IG
HT
D
IS
TA
NC
E (35 M
PH
)
340' R
IG
HT
T
UR
N S
IG
HT
D
IS
TA
NC
E (35 M
PH
)
280' LEFT TURN SIGHT DISTANCE (25 MPH)
240' RIGHT TURN SIGHT DISTANCE (25 MPH)
S. LENOIR STREET
S. W
ES
T S
TR
EE
T
S. H
AR
RIN
GT
ON
S
TR
EE
T
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16058
421 FAYETTEVILLE ST, STE 400
RALEIGH, NC 27601
T 919.380.8750
Client:
Vicinity map:
Issued for:
Title:
Sheet:Project number:
Date:
Drawn by:
Approved by:
Project:
522
S. HARRINGTON
STREET
Date Description
ADMINISTRATIVE SITE
REVIEW
No.
GREYMONT DEVELOPMENT LLC
8705 CATAMARAN DRIVE
RALEIGH , NC 27615
T: 919.656.6077
USE FOR CONSTRUCTION
W. CABARRUS ST.
NORTH
S. W
ES
T S
T.
W. SOUTH ST.
R
A
I
L
R
O
A
D
S. H
AR
RIN
GT
ON
S
T.
W. LEN
OIR
ST.
SITE
12.15.16 CITY COMMENTS1
05.25.17 CITY COMMENTS2
07.11.17 CITY COMMENTS3
10.13.17 CITY COMMENTS4
0 10 20 40
1"= 20'SCALE:
NORTH
Q
:\2
01
6\C
16
05
8 - 5
22
S
. H
arrin
gto
n S
tre
et\D
WG
S\1
- D
esig
n\S
he
ets\C
16
05
8-C
3.0
0-S
ite
P
la
n.d
wg
O
ct 1
3, 2
01
7 - 1
1:0
2a
m
SITE PLAN
C3.00
C16058
11.04.2016
SP/TSH
DMB
SITE DATA TABLE
ZONING: DX - 5 - UL
TOTAL ACREAGE: 0.77 AC (INCLUDING
EASEMENT PARCELS)
BUILD SETBACKS (MIN.)
SIDE PROPERTY LINE: 0' OR 6'
REAR PROPERTY LINE: 0' OR 6'
ALLEY 5'
BUILD-TO (URBAN FRONTAGE)
PRIMARY STREET (MIN./MAX.) 0' - 20'
BUILD WIDTH IN BUILD-TO 50'
SIDE STREET (MIN./MAX.) 0' - 20'
BUILD WIDTH IN BUILD-TO 25%
PARKING SETBACKS (MIN.)
PRIMARY STREET : 10'
SITE STREET: 10'
SIDE PROPERTY LINE: 0' OR 3'
REAR PROPERTY LINE: 0' OR 3'
ALLEY: 5'
VEHICULAR PARKING REQUIRED
RESIDENTIAL: 1 SPACE / D.U. 45 UNITS
(MINUS THE FIRST 16 UNITS) 29 SPACES
COMMERCIAL: 1 SPACE / 500 SF 1,836 SF
(MINUS THE FIRST 10,000 SF) 0 SPACES
TOTAL SPACES REQUIRED 29 SPACES
VEHICULAR PARKING PROVIDED 61 SPACES
BICYCLE PARKING REQUIRED
SHORT TERM: 1 SPACE / 20 UNITS 4 SPACES
(MIN. 4 SPACES)
LONG TERM: N/A --
SHORT TERM: 1 SPACE / 5000 SF 4 SPACES
(MIN. 4 SPACES)
BICYCLE PARKING PROVIDED 10 SPACES
TREE CONSERVATION AREA: N/A --
OUTDOOR AMENITY AREA REQUIRED: 10% 3,362 SF (0.077 AC)
STREET TYPOLOGY:
S. WEST STREET - MAIN STREET w/ PARALLEL PARKING (66' R/W)
S. HARRINGTON STREET - NEIGHBORHOOD STREET (64' R/W)
UPPER LEVEL PARKING - HARRINGTON STREET ACCESS
1"=30'
LOWER LEVEL PARKING - WEST STREET ACCESS
1"=30'
SIGHT TRIANGLES
1"=60'
SITE PLAN NOTES:
1. SOLID WASTE INSPECTIONS STATEMENT: THE OWNER ACKNOWLEDGES THAT THEY
HAVE REVIEWED AND ARE IN COMPLIANCE WITH THE REQUIREMENTS SET FORTH IN
THE SOLID WASTE DESIGN MANUAL. THE DEVELOPMENT PROPOSES TO UTILIZE A
PRIVATE WASTE HAULER FOR SOLID WASTE DISPOSAL. SHEET C3.00 IN THIS PLAN
SET INDICATES THE LOCATION OF THE PROPOSED DUMPSTER AND DUMPSTER
ENCLOSURE. SHEET C9.02 PROVIDES DETAILS FOR ENCLOSURE.
2. DECLARATION OF EASEMENTS FOR LIGHT, AIR, & OPEN SPACE AND CONSTRUCTION
AND ACCESS EASEMENTS BETWEEN 522 S HARRINGTON STREET AND 414 WEST
LENOIR AND 522 S HARRINGTON STREET AND 530 S HARRINGTON STREET TO
ADDRESS 0'-0" PROPERTY LINE SETBACK.
3. SITE LOCATED WITHIN LIMITS ESTABLISHED BY THE CHRISTMAS PLAN.
LEGEND:
CONCRETE
AMENITY AREA
CONCRETE PAVERS
TREE GRATE
D
D
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
D
D
D
STORMWATER
MANAGEMENT
PROPOSED 5-STORY
MIXED USE BUILDING w/
2-LEVEL PARKING
LOWER LEVEL - S. WEST
STREET ACCESS
UPPER LEVEL - S. HARRINGTON
STREET ACCESS
8"CLAY
8"C
LA
Y
6
"
C
L
A
Y
8"C
LA
Y
8"C
LA
Y
8"CLAY
8"C
LA
Y
8"CLA
Y
8"D
IP
6" V
CP
RIM=312.96'
IN=310.26'
OUT=310.26'
RIM=313.70'
IN(N)=308.90'
IN(NE)=309.30'
OUT=307.65'
RIM=304.01'
IN(N)=298.31'
IN(E)=298.81'
OUT=298.29'
RIM=302.92'
IN(N)=297.77'
IN(W)=297.47'
OUT=297.42'
RIM=316.52'
IN=309.22'
IN=299.22'
OUT=299.02'
RIM=323.13'
OUT=317.93'
(301.1LF
)
(243.9LF
)
CENTERLINE OF WIRE
DUKE ENERGY EASEMENT
DB. 13879, PG. 1535
"TRACT 2"
DUKE ENERGY EASEMENT
DB. 13879, PG. 1535
"TRACT 1"
POWER POLE
S88°36'16"W
N87°54'51"W 318.17'
NC DOT R/W EASMENT
(D.B. 13845, PG. 1905)
(D.B. 2963, PG. 662)
6" V
CP
8" CIP
8" DIP
6'' PVC SS SERVICE
6'' DIP W/S
FDC
TIE 6" PVC SS INTO
MANHOLE
6'' FIRE
12"X6" TEE WITH 6" GATE VALVE
S. W
ES
T S
TR
EE
T
66' P
UB
LIC
R
/W
S. LENOIR STREET
VARIABLE WIDTH PUBLIC R/W
S. H
AR
RIN
GT
ON
S
TR
EE
T
66' P
UB
LIC
R
/W
NOTE:
DOMESTIC AND FIRE PROTECTION
BACKFLOW PREVENTER INSIDE BLDG.
FOR FIRE USE " 6" RPDA WATTS 909 ".
FOR DOMESTIC USE " 4" RPZ WATTS
957N ".
4" METER
PROPOSED
FIRE HYDRANT
EXISTING FIRE
HYDRANT
12"X6" TEE WITH 6" GATE VALVE
PROPOSED 12" DIP WATERLINE TO TIE INTO EXISTING
LINES IN W. CABARRUS AND S. LENOIR STREET.
PROPOSED FIRE HYDRANT
12"X6" TEE WITH 6" GATE VALVE
4" DOMESTIC
8"X8" FULL-CIRCUMFERENTIAL ALL
STAINLESS STEEL TAPPING
SLEEVE & COMPONENTS WITH VALVE
8"X8" FULL-CIRCUMFERENTIAL ALL
STAINLESS STEEL TAPPING
SLEEVE & COMPONENTS WITH VALVE
PROPOSED 12" DIP WATERLINE TO
TIE INTO EXISTING LINES IN W.
CABARRUS AND S. LENOIR STREET.
8"X8" FULL-CIRCUMFERENTIAL ALL
STAINLESS STEEL TAPPING
SLEEVE & COMPONENTS WITH VALVE
12"X8" REDUCER
45 DEGREE BEND
8"X8" FULL-CIRCUMFERENTIAL ALL
STAINLESS STEEL TAPPING
SLEEVE & COMPONENTS WITH VALVE
12"X8" REDUCER
EXISTING WATERLINE TO BE
ABANDONED IN PLACE USING
FLOWABLE FILL
4" DIP TO TIE
INTO BUILDING
12"X8" REDUCER
12"X8" REDUCER
3.00'
5.00'
EXISTING WATERLINE TO BE
ABANDONED IN PLACE USING
FLOWABLE FILL
R/W
R/W
R/WR/W
EDGE OF SIDEWALK
1.00'
4.00'
5.00'
R/W
EDGE OF SIDEWALK
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16058
421 FAYETTEVILLE ST, STE 400
RALEIGH, NC 27601
T 919.380.8750
Client:
Vicinity map:
Issued for:
Title:
Sheet:Project number:
Date:
Drawn by:
Approved by:
Project:
522
S. HARRINGTON
STREET
Date Description
ADMINISTRATIVE SITE
REVIEW
No.
Se
GREYMONT DEVELOPMENT LLC
8705 CATAMARAN DRIVE
RALEIGH , NC 27615
T: 919.656.6077
USE FOR CONSTRUCTION
W. CABARRUS ST.
NORTH
S. W
ES
T S
T.
W. SOUTH ST.
R
A
I
L
R
O
A
D
S. H
AR
RIN
GT
ON
S
T.
W. LEN
OIR
ST.
SITE
12.15.16 CITY COMMENTS1
05.25.17 CITY COMMENTS2
07.11.17 CITY COMMENTS3
10.13.17 CITY COMMENTS4
0 10 20 40
1"= 20'SCALE:
NORTH
UTILITY LEGEND
EXISTING WATER LINE
PROPOSED WATER LINE
EXISTING SANITARY SEWER LINE
PROPOSED SANITARY SEWER LINE
PROPOSED FIRE HYDRANT
PROPOSED WATER VALVE
EXISTING SANITARY SEWER MANHOLE
PROPOSED SANITARY SEWER MANHOLE
PROPOSED CLEANOUT
PROPOSED FDC
PROPOSED POST INDICATOR VALVE (PIV)
300' HYDRANT COVERAGE CIRCLE
LIMITS OF DISTURBANCE
FDC
CO
H
Y
D
PIV
S
W
SS
WATER NOTES:
1. AS INDICATED, ALL WATERLINES SHALL BE DUCTILE IRON PIPE MEETING
THE REQUIREMENTS OF ANSI-AWWA C151 PRESSURE CLASS 350 OR
SOFT COPPER TYPE K PIPE PER ASTM B88. IF PVC WATERLINE IS
INDICATED ON THE PLANS IT SHALL MEET THE REQUIREMENTS OF
AWWA C-900; CLASS 200.
2. ALL WATERLINES SHALL HAVE A MINIMUM OF 3.5 FEET OF COVER.
3. TESTING NOTES:
PRESSURE:
LEAKAGE SHALL NOT EXCEED THE MAXIMUM ALLOWABLE LEAKAGE
SPECIFIED IN AWWA C 600. MINIMUM TEST PRESSURE SHALL BE 150
PSI FOR DOMESTIC AND 200 PSI FOR FIRE PROTECTION.
BACTERIOLOGICAL:
TWO SAMPLES FOR BACTERIOLOGICAL SAMPLING SHALL BE
COLLECTED AT LEAST 24 HOURS APART. IF CONTAMINATION IS
INDICATED, THEN THE DISINFECTION PROCEDURE AND TESTING SHALL
BE REPEATED UNTIL SATISFACTORY RESULTS ARE OBTAINED.
4. THE CHLORINE IN HEAVILY CHLORINATED WATER FLUSHED FROM MAINS
NEEDS TO BE NEUTRALIZED BEFORE DISCHARGE. CONTRACTORS
SHALL NEUTRALIZE HEAVILY CHLORINATED WATER FLUSHED FROM
MAINS PRIOR TO DISCHARGE OR TRANSPORT ALL HEAVILY
CHLORINATED WATER OFFSITE FOR PROPER DISPOSAL.
5. PAINT VALVE COVERS, FIRE HYDRANTS AND OTHER WATER APPARATUS
TO MEET THE LOCAL JURISDICTIONAL REQUIREMENTS.
6. CONTINUOUS WATER SERVICE SHALL BE MAINTAINED TO ALL EXISTING
BUSINESSES AND FIRE HYDRANTS ON HARRINGTON ST AND S. WEST ST.
SEWER NOTES:
1. SANITARY SEWER CLEANOUTS LOCATED IN PAVEMENT AREAS SHALL BE
HEAVY DUTY TRAFFIC BEARING CASTINGS.
2. UNLESS OTHERWISE NOTED, ALL SANITARY SEWER MANHOLES ARE 4'
DIA.
3. MANHOLES LOCATED IN PAVEMENT, CONCRETE OR OTHER TRAFFIC
AREAS SHALL BE SET AT GRADE. MANHOLES LOCATED IN OTHER AREAS
(I.E. GRASS OR WOODED AREAS) SHALL HAVE THEIR RIMS RAISED SIX
INCHES ABOVE THE SURROUNDING GRADE. MANHOLES SUBJECT TO
POSSIBLE WATER INFILTRATION SHALL HAVE WATERTIGHT, BOLTED
LIDS.
4. MINIMUM REQUIRED SLOPES FOR SEWER SERVICES:
4" SEWER SERVICE - 2.00% SLOPE
6" SEWER SERVICE - 1.00% SLOPE
8" SEWER SERVICE - 0.50% SLOPE
5. UNLESS OTHERWISE NOTED, LOCATE SANITARY SERVICE CLEANOUTS
AT ALL HORIZONTAL OR VERTICAL CHANGES IN DIRECTION. MAXIMUM
SPACING BETWEEN CLEANOUTS SHALL BE 75 FEET.
6. SEWER LINES LESS THAN 3 FEET OF COVER SHALL BE CLASS 50 DUCTILE
IRON PIPE. SEWER LINES WITH GREATER THAN 3 FEET OF COVER SHALL
BE AS NOTED BELOW:
4" SEWER SERVICE - SCH 80
6" SEWER SERVICE - SCH 80
8" SEWER SERVICE - SDR-35
7. SEWER LINES UNDER CONSTRUCTION SHALL BE PROTECTED FROM
DIRT, DEBRIS OR OTHER CONTAMINANTS ENTERING THE NEW SYSTEM.
A MECHANICAL PLUG SHALL BE UTILIZED BOTH IMMEDIATELY UPSTREAM
OF THE NEW CONSTRUCTION AND AT THE FIRST MANHOLE
DOWNSTREAM IN THE EXISTING SYSTEM. EXISTING STRUCTURES,
PIPING AND APPURTENANCES SHALL BE PROTECTED FROM ANY INFLOW
OF WATER, DIRT OR DEBRIS DUE TO NEW CONSTRUCTION CONNECTING
TO OR IN THE VICINITY OF THE EXISTING SYSTEM. CONTRACTOR TO
REMOVE DEBRIS AND PLUG PRIOR TO OCCUPANCY.
8. ALL MANHOLES COVERS SHALL BE PAINTED TO LOCAL JURISDICTIONAL
REQUIREMENTS.
Q
:\2
01
6\C
16
05
8 - 5
22
S
. H
arrin
gto
n S
tre
et\D
WG
S\1
- D
esig
n\S
he
ets\C
16
05
8-C
6.0
0-U
tility P
la
n.d
wg
O
ct 1
3, 2
01
7 - 1
1:0
3a
m
UTILITY PLAN
C6.00
C16058
11.04.2016
SP/TSH
DMB
FIRE FLOW REQUIREMENTS
- METHOD OF DETERMINING REQUIRED FLOW:
- NC FIRE CODE - APPENDIX B
- BUILDING TYPE - TYPE V-B
- BUILDING SQUARE FOOTAGE -87,500 SF
- REQUIRED FLOW PER TABLE B105.1 - 2,750 GPM
- FLOW AVAILABLE = 1,483 GPM @ 20 PSI*
* FLOW CALCULATED BASED ON FIRE FLOW TEST PREFORMED BY STEWART, INC. AND
WITNESSES BY STEVE BERRY FROM THE CITY OF RALEIGH ON 2016.08.15.
WATER METER INSET
NOTE;
CONTRACTOR TO FIELD VERIFY EXISTING WATER LINE LOCATIONS PRIOR TO THE
INSTALLATION OF THE PROPOSED WATER LINES.
STORMWATER
MANAGEMENT
PROPOSED 5-STORY
MIXED USE BUILDING w/
2-LEVEL PARKING
LOWER LEVEL - S. WEST
STREET ACCESS
UPPER LEVEL - S. HARRINGTON
STREET ACCESS
S. W
ES
T S
TR
EE
T
66' P
UB
LIC
R
/W
W. LENOIR STREET
VARIABLE WIDTH PUBLIC R/W
S. H
AR
RIN
GT
ON
S
TR
EE
T
66' P
UB
LIC
R
/W
DUKE ENERGY EASEMENT
DB. 13879, PG. 1535
"TRACT 2"
DUKE ENERGY EASEMENT
DB. 13879, PG. 1535
"TRACT 1"
6 | AMGR
4 | CHVI
3 | QUPH
SIGHT TRIANGLE (TYP).
4'x6' METAL TREE GRATE WITH
STRUCTURAL SOIL SYSTEM
PER CITY OF RALEIGH DETAILS
4'x6' METAL TREE GRATE WITH
STRUCTURAL SOIL SYSTEM
PER CITY OF RALEIGH DETAILS
EXISTING OVERHEAD
POWER LINE
SIGHT DISTANCE
TRIANGLE
SIGHT DISTANCE
TRIANGLE
SIGHT DISTANCE
TRIANGLE
4'x6' METAL TREE GRATE WITH
STRUCTURAL SOIL SYSTEM
PER CITY OF RALEIGH DETAILS
DUKE ENERGY EASEMENT
PROPOSED
RETAINING WALL
3 | COFL
1 | MAGR
TREES QTY. BOTANICAL NAME COMMON NAME CONT CAL HGT REMARKSCHVI 4 CHIONANTHUS VIRGINICUS FRINGE TREE B & B 1-1/2" CAL 6' MIN. SINGLE-STEMQUPH 3 QUERCUS PHELLOS WILLOW OAK B & B 3" CAL 10' MIN. SINGLE-STEMMAGR 1 MAGNOLIA GRANDIFLORA 'LITTLE GEM' LARGE-FLOWERED MAGNOLIA B & B 2" CAL 6' MIN.
AMGR 6AMELANCHIER X GRANDIFLORA'AUTUMNBRILLIANCE' SERVICEBERRY B & B 2" CAL 6' MIN. SINGLE-STEM
COFL 3 CORNUS FLORIDA'APPALACHIAN SPRING' DOGWOOD B & B 2" CAL 6' MIN
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16058
421 FAYETTEVILLE ST, STE 400
RALEIGH, NC 27601
T 919.380.8750
Client:
Vicinity map:
Issued for:
Title:
Sheet:Project number:
Date:
Drawn by:
Approved by:
Project:
522
S. HARRINGTON
STREET
Date Description
ADMINISTRATIVE SITE
REVIEW
No.
GREYMONT DEVELOPMENT LLC
8705 CATAMARAN DRIVE
RALEIGH , NC 27615
T: 919.656.6077
W. CABARRUS ST.
NORTH
S. W
ES
T S
T.
W. SOUTH ST.
R
A
I
L
R
O
A
D
S. H
AR
RIN
GT
ON
S
T.
W. LEN
OIR
ST.
SITE
12.15.16 CITY COMMENTS1
05.25.17 CITY COMMENTS2
07.11.17 CITY COMMENTS3
10.13.17 CITY COMMENTS4
LANDSCAPING NOTES:
1. VERIFY ALL QUANTITIES AND REPORT ANY DISCREPANCIES OR INACCURACIES IN THE PLANS TO THE OWNER'S REPRESENTATIVE
PRIOR TO PLANTING.
2. LANDSCAPE WORK SHALL INCLUDE THE FURNISHING, INSTALLATION, AND WARRANTY OF ALL PLANTING MATERIALS WITHIN THE
PROJECT AREA.
3. THE LANDSCAPE CONTRACTOR SHALL ASCERTAIN THE LOCATION OF ALL EXISTING AND NEW UNDERGROUND UTILITIES PRIOR
TO EXCAVATION FOR PLANTING. DAMAGES TO UTILITIES CAUSED BY THE LANDSCAPE OPERATION SHALL BE CORRECTED BY
THE LANDSCAPE CONTRACTOR AT NO COST TO THE OWNER.
4. LANDSCAPING SHALL REMAIN CLEAR FROM ANY FIRE HYDRANTS ON THE SITE.
5. ALL TREES TO BE A MINIMUM OF 2" IN CALIPER AND MUST MEET THE AMERICAN STANDARD FOR NURSERY STOCK.
6. TREE PROTECTION NOTE: TREE PROTECTION FENCING MUST BE IN PLACE PRIOR TO ANY DEMOLITION, LAND DISTURBANCE OR
ISSUANCE OF A GRADING PERMIT AND SHALL INCLUDE WARNING SIGNS POSTED IN BOTH ENGLISH AND SPANISH, AS FOLLOWS:
"NO TRESPASSING/TREE PROTECTION AREA/PROHIBIDO ENTRAR / ZONA PROTECTORA PARA LOS ÁRBOLES."
7. PROTECTION OF EXISTING VEGETATION: AT THE START OF GRADING INVOLVING THE LOWERING OF EXISTING GRADE AROUND A
TREE OR STRIPPING OF TOPSOIL, A CLEAN, SHARP, VERTICAL CUT SHALL BE MADE AT THE EDGE OF THE TREE SAVE AREA AT
THE SAME TIME AS OTHER EROSION CONTROL MEASURES ARE INSTALLED. THE TREE PROTECTION FENCING SHALL BE
INSTALLED ON THE SIDE OF THE CUT FARTHEST AWAY FROM THE TREE TRUNK AND SHALL REMAIN IN PLACE UNTIL ALL
CONSTRUCTION IN THE VICINITY OF THE TREES IS COMPLETE. NO STORAGE OF MATERIALS, FILL, OR EQUIPMENT AND NO
TRESPASSING SHALL BE ALLOWED WITHIN THE BOUNDARY OF THE PROTECTED AREA.
8. ROOT ZONE PROTECTION AREA: VARIES BASED ON LOCAL JURISDICTION HAVING AUTHORITY. CONTRACTOR SHALL COMPLY
WITH LOCAL JURISDICTIONAL REQUIREMENTS. NO DISTURBANCE ALLOWED WITHIN THIS AREA. AREA MUST BE PROTECTED
WITH BOTH TREE PROTECTION FENCING AND WARNING SIGNS.
9. SEED BED PREPARATION: ALL AREAS TO BE SEEDED ARE TO BE RECEIVE A MINIMUM OF 2" OF APPROVED TOPSOIL. ALL DEBRIS,
ROCKS, ETC. LARGER THAN .5" ARE TO BE REMOVED. ALL LARGE CONCENTRATIONS OF GRAVEL & DEBRIS REGARDLESS OF SIZE
ARE TO BE REMOVED PRIOR TO SEEDING OR PLANTING.
10. ALL PLANT BED AREAS ARE TO RECEIVE A MINIMUM OF 6" OF APPROVED TOPSOIL.
11. SOIL SHOULD BE TESTED AND AMENDED WITH LIME AND FERTILIZER FOR HARDWOOD TREES ACCORDING TO NCDA
PROCEDURES. SCARIFY PLANT PIT WALLS. CONSULT LANDSCAPE ARCHITECT FOR ALTERNATE COMPLIANCE.
12. SHREDDED HARDWOOD MULCH 3" DEEP EXCEPT AT CROWN OF PLANT UNLESS OTHERWISE NOTED. FLARE AT CROWN SHOULD
BE REVEALED. BACKFILL CONSISTS OF THOROUGHLY BROKEN UP NATIVE SOIL. TOTAL VOLUME OF BACKFILL SHOULD BE
AMENDED WITH UP TO ONE THIRD PINE BARK MULCH. PIECES SHOULD BE NO LARGER THAN WHAT PASSES THROUGH A ONE
INCH SCREEN. IF ADDITIONAL SOIL IS REQUIRED FOR BACKFILL DUE TO DETRIMENTAL SUBSOIL DRAINAGE CONDITIONS, USE
SOIL SIMILAR TO EXISTING NATIVE SOIL. ADDITIONAL SOIL TO BE APPROVED BY LANDSCAPE ARCHITECT. MAXIMUM SAUCER
HEIGHT IS 6 INCHES.
13. FOR B&B PLANTS, NATURAL FIBER BURLAP SHOULD BE TURNED DOWN BY 1/3 TOTAL HEIGHT OF ROOT BALL. PLASTIC FIBER
BURLAP AND WIRE BASKETS SHOULD BE REMOVED TO 2/3'S OF TOTAL HEIGHT OF ROOT BALL.
14. CONTRACTOR IS RESPONSIBLE FOR KEEPING THE TREE UPRIGHT AND PLUMB THROUGHOUT THE WARRANTY PERIOD. IF
STABILIZATION IS NECESSARY SEE STAKING IN TREE DETAIL, ORANGE FLAGGING TAPE SHOULD BE ATTACHED TO SUPPORT
WIRE. STAKING SHOULD BE REMOVED BY CONTRACTOR AT END OF ONE YEAR WARRANTY PERIOD OR AS DIRECTED BY
GROUNDS MANAGEMENT.
15. USE STANDARD "GATOR" BAGS FOR WATERING TREES IN AREAS NOT UNDER IRRIGATION. INCORPORATE TERRA-SORB (OR
EQUAL) AS PER MANUFACTURERS RECOMMENDATIONS, FOR AREAS NOT UNDER IRRIGATION.
16. USE "BIO-BARRIER" OR EQUIVALENT ACCORDING TO MANUFACTURER'S RECOMMENDATION FOR TREES THAT WILL BE PLANTED
WITHIN 10' OF PAVEMENT
17. LANDSCAPING/C.O. STANDARDS NOTE: ALL LANDSCAPING MUST BE IN PLACE PRIOR TO REQUEST FOR A CERTIFICATE OF
COMPLIANCE.
18. FOLLOW CITY OF RALEIGH INSTALLATION AND MAINTENANCE STANDARDS IN CHAPTER 2 OF CITY TREE MANUAL
19. A TREE IMPACT PERMIT FOR TREES INSTALLED IN THE PUBLIC RIGHT-OF-WAY IS REQUIRED PRIOR TO THE ISSUANCE OF BUILDING
PERMITS.
0 10 20 40
1"= 20'SCALE:
NORTH
Q
:\2
01
6\C
16
05
8 - 5
22
S
. H
arrin
gto
n S
tre
et\D
WG
S\1
- D
esig
n\S
he
ets\C
16
05
8-L
1.0
0-P
la
ntin
g P
la
n.d
wg
O
ct 1
3, 2
01
7 - 1
1:0
3a
m
LANDSCAPE PLAN
L1.00
C16058
11.04.2016
KS/ME
MPT
LARGE TREES
CHIONANTHUS
VIRGINICUS
LANDSCAPE LEGEND
UNDERSTORY TREES
LANDSCAPE CALCULATIONS
STREET TREES
S. WEST STREET
TREES REQUIRED
TREES PROVIDED
* UNDERSTORY TREES PROPOSED
UNDER OVERHEAD POWER LINES
S. LENOIR ST.
TREES REQUIRED
TREES PROVIDED
S. HARRINGTON ST
TREES REQUIRED
TREES PROVIDED
* UNDERSTORY TREES PROPOSED
UNDER OVERHEAD POWER LINES
AMENITY AREA
TREES REQUIRED
TREES PROVIDED
* UNDERSTORY TREES PROPOSED
UNDER OVERHEAD POWER LINES
162 LF (183 - 21 LF OF DRIVEWAY)
4 (40' O.C.)
4
211 LF
5 (40' O.C.)
6
111 LF (135 - 24 LF OF DRIVEWAY)
3 (40' O.C.)
3
3,362 SF
3.4
4
QUERCUS
PHELLOS
BIORETENTION
PLANTINGS
SUPPLEMENTAL BANK STABILIZATION
AND ACCENT PLANTINGS
PLANTING NOTES:
1. DO NOT STAKE TREES EXCEPT WHERE SPECIFIED BY LANDSCAPE ARCHITECT. STAKING IS REQUIRED FOR TREES PLANTED ON
SLOPES.
2. WHERE SEVERAL TREES WILL BE PLANTED CLOSE TOGETHER SUCH THAT THEY WILL LIKELY SHARE ROOT SPACE, TILL IN SOIL
AMENDMENTS TO A DEPTH OF 4-6" OVER THE ENTIRE AREA.
3. FOR CONTAINER GROWN TREES, USE FINGERS OR SMALL HAND TOOLS TO PULL THE ROOTS OUT OF THE OUTER LAYER OF
POTTING SOIL; THEN CUT OR PULL APART ANY ROOTS CIRCLING THE PERIMETER OF THE CONTAINER.
4. FOR FIELD GROWN TREES, CUT BURLAP, ROPE AND WIRE BASKET AWAY FROM TOP AND SIDES OF ROOT BALL.
5. THOROUGHLY SOAK THE TREE ROOT BALL AND ADJACENT PREPARED SOIL SEVERAL TIMES DURING THE FIRST MONTH AFTER
PLANTING AND REGULARLY THROUGHOUT THE FOLLOWING TWO SUMMERS.
6. THE PLANTING PROCESS IS SIMILAR FOR DECIDUOUS AND EVERGREEN TREES.
7. DO NOT WRAP TRUNK; MARK NORTH SIDE OF TREE IN THE NURSERY AND LOCATE TO THE NORTH IN THE FIELD.
8. WIDTH OF PLANTING HOLE IS 3X ROOT BALL AT THE SURFACE, SLOPING TO 2X THE ROOT BALL DIAMETER AT THE DEPTH OF THE
ROOT BALL.
9. BEFORE PLANTING, ADD 3-4" OF WELL COMPOSTED LEAVES, RECYCLED YARD WASTE OR OTHER COMPOST AND TILL INTO TOP 6"
OF PREPARED SOIL. ADD COMPOST AT 20-35% BY VOLUME TO BACKFILL.
10. PERFORM PERCOLATION TEST FOR EACH TREE PIT TO CONFIRM THAT WATER DRAINS OUT OF THE SOIL. PROVIDE GRAVEL SUMP
FILTER FABRIC & VENT PIPE IF DRAINAGE DOES NOT OCCUR WITHIN 24 HOURS. INCLUDE ALL SUMPS IN BASE BID. SHOULD SUMPS
NOT BE NECESSARY AFTER PERCOLATION TEST, PROVIDE CHANGE ORDER DEDUCT TO OWNER.
11. IF PLANTING HOLES ARE DUG WITH A LARGE AUGER BREAKING DOWN THE SIDES WITH A SHOVEL CAN ELIMINATE GLAZING AND
CREATE THE PREFERRED SLOPING SIDE.
12. TREES SHALL HAVE SINGLE LEADERS. TREES WITH 2 LEADERS WILL BE REJECTED.
13. DO NOT PLACE MULCH IN CONTACT WITH TRUNK.
14. PROVIDE GATOR BAGS FOR ALL TREES WHERE IRRIGATION IS NOT PROVIDED.
15. FOR ALL STREET TREES LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY, 600 CUBIC FEET OF HIGH QUALITY SUBSURFACE
STRUCTURAL TOP SOIL SHALL BE PLACED WITHIN THE IMMEDIATE AREA WHERE THE TREE IS TO BE PLACED PER THE CITY OF
RALEIGH STREET DESIGN MANUAL.
CORNUS FLORIDA
'APPALACHIAN
SPRING'
AMELANCHIER
GRANDIFLORA
'AUTUMN BRILLIANCE'
ACCENT PLANTINGS
TURF
GROUNDCOVER & UNDERSTORY
PLANTINGS
MAGNOLIA
GRANDIFLORA
'LITTLE GEM'
PLANT SCHEDULE
THE STORMWATER CONTROL DEVICE IS INTENDED TO BE PART OF THE AMENITY AREA AND WILL BE
INTEGRATED INTO THE OVERALL LANDSCAPE DESIGN. THE STORMWATER AREA WILL MEET ALL REQUIRED
BASIC AND SUPPLEMENTAL AMENITY FEATURES OF 7.2.6-B-1 AND 7.2.6-B-2-B. IT WILL FEATURE THE
FOLLOWING:
· DIRECT ACCESS FROM THE ADJACENT AMENITY AREA;
· MATERIALS WHICH SHARE AN AESTHETIC STYLE WITH THE ADJACENT BUILDING;
· PLANT MATERIAL WHICH IS INTEGRATED INTO THE ADJACENT PLANTINGS IN THE AMENITY AREA;
· RETAINING WALLS AND/OR SLOPING SIDES NO GREATER THAN 4:1; AND
· FULL PLANT COVERAGE WITH SPECIES THAT CAN WITHSTAND EXTENDED PERIODS OF INUNDATION.
UDO PLANNING AND SCREENING COMPLIANCE
522
HAR
RIN
GTO
N S
TREE
TTH
E RA
LEIG
H A
RCHI
TECT
URE
CO
.
ELEVATIONS
SHEET:
A300
DATE:
ARCHITECT:The Raleigh Architecture Co. NC# 52702
ADMINISTRATIVESITE REVIEW
JULY 07, 2017
DRAWN BY: TM
CHECKED BY: RJ
REVISIONS:
ROBBY JOHNSTON NC# 11330
MIX
ED U
SE /
RES
IDEN
TIAL
522
HAR
RIN
GTO
N S
T.
tel.9
19 8
31 2
955
ID: RA1608
6/19/17 Overhang Depth
RAL
EIG
H, N
C 2
7601
502
SOU
TH W
EST
STRE
ET,
SUIT
E 10
0R
ALEI
GH
NC
276
01
©COPYRIGHT
THESE DRAWINGS AREPROPERTY OF THE
ARCHITECT AND MAY NOTBE REPRODUCED WITHOUT
THE PERMISSION OF AREPRESENTATIVE OF theRALEIGH ARCHITECTURE
CO.
©COPYRIGHT
THESE DRAWINGS AREPROPERTY OF THE
ARCHITECT AND MAY NOTBE REPRODUCED WITHOUT
THE PERMISSION OF AREPRESENTATIVE OF theRALEIGH ARCHITECTURE
CO.
1
FOR
REVI
EW P
URPO
SES
ONLY
NOT
FOR
CONS
TRUC
TION
Floor Heights2 7/7/17
11'-0"STORY 1 (P1) S HARRINGTON ST.
28'-8"STORY 2
39'-0"STORY 3
0'-0" (310.5')STORY 1 (P1) S WEST ST.
49'-4"STORY 4
59'-8"STORY 5
-1'-0"AVG GRADE PLANE (S WEST ST.)
74'-0" (75'-0" FROM AVG GRADE)MAX BUILD HEIGHT (S WEST ST.)80'-0"MAX PARAPET HEIGHT (S WEST ST.)86'-0"MAX MONITOR HEIGHT (S WEST ST.)
-3'-6" (307.0)FIRE ACCESS
71'-6" (382.0)MAX BUILD HEIGHT (FIRE ACCESS)
PEDESTRIAN ACCESS TO LOBBY
VEHICULAR ACCESS DOORS, SCREENED FOR VENTILATION
GLAZING
TOP OF BUILDING HARRINGTON STREET SIDE
75'-0
"
RESI
DENT
IAL
COMM
ERCI
AL
TOP OF BUILDING
TOP OF ROOF MONITOR
EXTERIOR BALCONY & RAILING
METAL SIDING
GLAZING
BUILDING BEYOND
MASONRY
2
11'-0"STORY 1 (P2) S HARRINGTON ST.
0'-0" (310.5')STORY 1 (P1) S WEST ST.
84'-1 1/2" (75'-0" FROM AVG GRADE)MAX BUILD HEIGHT (S HARRINGTON ST.)
74'-0" (75'-0" FROM AVG GRADE)MAX BUILD HEIGHT (S WEST ST.)80'-0"MAX PARAPET HEIGHT (S WEST ST.)86'-0"MAX MONITOR HEIGHT (S WEST ST.)
-1'-0"AVG GRADE PLANE (S WEST ST.)
9'-1 1/2"AVG GRADE PLANE (S HARRINGTON ST.)
90'-1 1/2"MAX PARAPET HEIGHT (S HARRINGTON ST.)
75'-0
"
STEEL SCREEN FOR P2 PARKING NATURAL VENTILATION
GLAZING
TOP OF BUILDING
75'-0
"
23'-1 1/8"
TOP OF BUILDINGTOP OF ROOF MONITOR
10'-1
"
MASONRY
EXTERIOR BALCONY& RAILING
GLAZING
5'-0" TYP.
METAL SIDING
MAX HEIGHT REQUIREMENTSFOR S HARRINGTON ST.
MAX HEIGHT REQUIREMENTSFOR S. WEST ST.
NOT STREET FACING FACADE
ELEVATIONS COMPLETELY EXEMPT FROM
BLANK WALL/TRANSPARENCY REQUIREMENTS
28'-8"STORY 2
39'-0"STORY 3
49'-4"STORY 4
59'-8"STORY 5
-3'-6" (307.0)FIRE ACCESS
71'-6" (382.0)MAX BUILD HEIGHT (FIRE ACCESS)
10'-1
"
2
VEHICULAR ACCESS DOORS, SCREENED FOR VENTILATION
STAIR ENTRY
GLAZING
TOP OF BUILDING
84'-1 1/2" (75'-0" FROM AVG GRADE)MAX BUILD HEIGHT (S HARRINGTON ST.)
90'-1 1/2"MAX PARAPET HEIGHT (S HARRINGTON ST.)
9'-1 1/2"AVG GRADE PLANE (S HARRINGTON ST.)
75'-0
"
RESI
DENT
IAL
COMM
ERCI
AL
EXISTING BUILDING ON ADJACENT PROPERTY
EXTERIOR BALCONY & RAILING
METAL SIDING
GLAZING
MASONRY
15'-0
"
BUILDING BEYOND
10'-1
"
TRANSPARENCY & BLANK WALL CALCULATIONSELEVATION TRANSPARENCY - GROUND FLOOR TRANSPARENCY - UPPER FLOORS BLANK WALL AREA
REQUIRED (MIN) SHOWN REQUIRED (MIN) SHOWN MAX ALLOWABLE AREA SHOWN (SF)NORTH N/A - N/A - N/A -
EAST 66% (809 SF) 67% (827 SF) N/A - 20' (400 SF) 140 SFSOUTH N/A - N/A - N/A -
WEST 66% (1,080 SF) 71% (1,167 SF) N/A - 20' (400 SF) 316 SF
NOTES: 1. ZONING DX-5-UL2. R.O.W. PER MIXED USE STREETS SEC. 8.4.5.D MAIN STREET PARALLEL PARKING STREETSCAPE 3. NO FRONTAGE REQUIREMENTS ALONG LENOIR STREET4. NO GLAZING/BLANK WALL REQUIREMENTS ON SOUTH AND NORTH ELEVATION (NOT STREET FACING FACADES)5. NO GLAZING REQUIREMENTS ON RESIDENTIAL FLOORS
TRANSPARENCY DEPTH REQUIREMENTS PER UDO 1.5.9.B.3 MET (60% OF GLAZING 8' MIN. VISIBILITY DEPTH)
WEST ELEVATION: S. WEST STREET041/16"=1'-0" 0 321684
SOUTH ELEVATION: W LENOIR STREET021/16"=1'-0" 0 321684
EAST ELEVATION: S HARRINGTON STREET031/16"=1'-0" 0 321684
84'-1 1/2" (75'-0" FROM AVG GRADE)MAX BUILD HEIGHT (S HARRINGTON ST.)90'-1 1/2"MAX PARAPET HEIGHT (S HARRINGTON ST.)
11'-0"STORY 1 (P2) S HARRINGTON ST.
0'-0" (310.5')STORY 1 (P1) S WEST ST.
74'-0" (75'-0" FROM AVG GRADE)MAX BUILD HEIGHT (S WEST ST.)
80'-0"MAX PARAPET HEIGHT (S WEST ST.)
86'-0"MAX MONITOR HEIGHT (S WEST ST.)
-1'-0"AVG GRADE PLANE (S WEST ST.)
9'-1 1/2"AVG GRADE PLANE (S HARRINGTON ST.)
75'-0
"
ROOF ACCESS MONITORTOP OF BUILDING
TOP OF BUILDING
75'-0
"
11'-3"
10'-1
"
GLAZING
MASONRY
EXTERIOR BALCONY& RAILING
STEEL SCREEN FOR P2 PARKINGNATURAL VENTILATION
GLAZING
METAL SIDING METAL SIDING
MAX HEIGHT REQUIREMENTSFOR S HARRINGTON ST.
MAX HEIGHT REQUIREMENTSFOR S. WEST ST.
NOT STREET FACING FACADE
ELEVATIONS COMPLETELY EXEMPT FROM
BLANK WALL/TRANSPARENCY REQUIREMENTS
28'-8"STORY 2
39'-0"STORY 3
49'-4"STORY 4
59'-8"STORY 5
-3'-6" (307.0)FIRE ACCESS
71'-6" (382.0)MAX BUILD HEIGHT (FIRE ACCESS)
2
NORTH ELEVATION011/16"=1'-0" 0 321684