  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

SPLIT TYPEGREEN SOURCE AIR / AIR HEAT PUMPOPERATION MANUAL

Must be installed by a qualified refrigerant engineer

INDOOR UNIT OUTDOOR UNIT

WAAIU6 WAAOU6

The two units below will only operate together and can not be used with any other product

WAAIU6_cover.indd 1 2012-4-12 13:15:37

Page 2: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

A. Information on Disposal for Users (private households)1. In the European UnionAttention: If you want to dispose of this equipment, please do not use the ordinary dustbin! Used electrical and electronic equipment must be treated separately and inaccordance with legislation that requires proper treatment, recovery and recycling ofused electrical and electronic equipment. Following the implementation by member states, private households within the EUstates may return their used electrical and electronic equipment to designatedcollection facilities free of charge*. In some countries* your local retailer may alsotake back your old product free of charge if you purchase a similar new one.*) Please contact your local authority for further details.If your used electrical or electronic equipment has batteries or accumulators, pleasedispose of these separately beforehand according to local requirements. By disposing of this product correctly you will help ensure that the waste undergoesthe necessary treatment, recovery and recycling and thus prevent potential negativeeffects on the environment and human health which could otherwise arise due toinappropriate waste handling.

2. In other Countries outside the EUIf you wish to discard this product, please contact your local authorities and ask for thecorrect method of disposal. For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collectionfacilities are listed on the homepage of www.swico.ch or www.sens.ch.

B. Information on Disposal for Business Users.1. In the European UnionIf the product is used for business purposes and you want to discard it:Please contact your WORCESTER dealer who will inform you about the take-back of theproduct. You might be charged for the costs arising from take-back and recycling.Small products (and small amounts) might be taken back by your local collectionfacilities.For Spain: Please contact the established collection system or your local authority fortake-back of your used products.

2. In other Countries outside the EUIf you wish to discard of this product, please contact your local authorities and ask forthe correct method of disposal.

Attention: Your product ismarked with this symbol. Itmeans that used electricaland electronic productsshould not be mixed withgeneral household waste.There is a separatecollection system for theseproducts.

EN

The battery supplied with this product contains traces of Lead.For EU: The crossed-out wheeled bin implies that used batteries should not be put to the general household waste! There is a separate collection system for used batteries, to allow proper treatment and recycling in accordance with legislation. Please contact your local authority for details on the collection and recycling schemes.For Switzerland: The used battery is to be returned to the selling point.For other non-EU countries: Please contact your local authority for correct method of disposal of the used battery.

Contains fluorinated greenhouse gases covered by the Kyoto ProtocolR410A (Global warming potential 1980)

Pb

BUILDING REGULATIONSThis appliance must be installed and serviced only by a competent person in accordance with the current: IEE Regulations, Building Regulation, Building Standards (Scotland) (Consolidation), Building Regulations (Northern Ireland), local water by-laws, Health & Safety Document 63S (The Electricity at Work Regulations 1989), IS 813 (Eire) and other local requirements.The relevant Standards should be followed, including:BS EN 14511: Requirements heat pumps for space heating and coolingBS EN 378: Safety and environmental requirements for heat pumps BS EN 14324 BrazingBS 1306 Specification for copper & copper Alloy pressure piping systemThe Health and Safety at Work Act 1974The Management of Health and Safety at Work Regulations 1999The Construction (Health, Safety and Welfare) Regulations 1996The Construction (Design and Management) Regulations 1994The Lifting Operations and Lifting Equipment Regulations 1998Where no specific instructions is given, reference should be made to the relevant codes of Practice.

WAAIU6_cover.indd 2 2012-4-12 13:15:38

Page 3: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

1

CONTENTS

• IMPORTANTSAFETYINSTRUCTIONS........... 1• PARTNAMES.................................................... 2•USINGTHEREMOTECONTROL.................... 4• TIPSONSAVINGENERGY.............................. 5• AUXILIARYMODE............................................ 5• BASICOPERATION.......................................... 6• ADJUSTINGTHEAIRFLOWDIRECTION....... 7• PROGRESSIVEAIRFLOW............................... 8• FULLPOWEROPERATION.............................. 8• PLASMACLUSTEROPERATION..................... 9• SELFCLEANOPERATION............................... 9•ONE-HOUROFFTIMER................................... 10• TIMEROPERATION.......................................... 10• 10˚COPERATION............................................. 12• ADDITIONALNOTESONOPERATION............ 12•DISPLAYBUTTON............................................ 12•MAINTENANCE................................................. 13• BEFORECALLINGFORSERVICE.................. 14

WARNINGS FOR INSTALLATION/REMOVAL/REPAIR• Donotattemptto install/remove/repair theunitbyyourself. Incorrectworkwill cause electric shock,water leak, fire etc. Consult your dealer or otherqualified service personnel for the installation/removal/repairoftheunit.

CAUTIONS FOR USE

1 Openawindowordoorperiodically toventilatetheroom,especiallywhenusinggasappliances.Insufficient ventilation may cause oxygenshortage.

2Do not operate the buttons with wet hand. Itmaycauseelectricshock.

3Forsafety, turn thecircuitbreakeroffwhennotusingtheunitforanextendedperiodoftime.

4Check the outdoor un i t mount ing rackperiodicallyforwearandtomakesureitisfirmlyinplace.

5Do not put anything on the outdoor unit norstand on it. The object or the person may falldownordrop,causinginjury.

6Thisunitisdesignedforresidentialuse.Donotuseforotherapplicationssuchasinakennelorgreenhousetofeedanimalsorgrowplants.

7Do not place a vessel with water on the unit.If water penetrates into the unit, electricalinsulations may deteriorate and cause electricshock.

8Donotblocktheair inletsoroutletsoftheunit.Itmaycauseperformanceissuesandtechnicalproblems.

9Stop the operation and turn the circuit breakeroff before performing any maintenance orcleaning.Afanisrotatinginsidetheunitandyoumaygetinjured.

10Donotsplashorpourwaterdirectlyontheunit.Watercancauseelectricalshockorequipmentdamage.

11Thisapplianceisnotintendedforusebyyoungchildrenorinfirmpersonswithoutsupervision.

Youngchildrenshouldbesupervised toensurethattheydonotplaywiththeappliance.

CAUTIONS FOR LOCATION/INSTALLATION• Make sure to connect the air/air heat pump topowersupplyoftheratedvoltageandfrequency.

Useofapowersupplywithimpropervoltageandfrequency can result in equipment damage andpossiblefire.

• Do not install the unit in a place where inflam-mablegasmayleak.Itmaycausefire.

Installtheunitinaplacewithminimaldust,fumesandmoistureintheair.

• Arrange the drain hose to ensure smooth drain-age.Insufficientdrainagemaycausewettingoftheroom,furnitureetc.

• Make sure a leak breaker or a circuit breaker isinstalled,dependingontheinstallationlocation,toavoidelectricalshock.

IMPORTANT SAFETY INSTRUCTIONS

WARNINGS FOR USE

1 Do not pull or deform the power supply cord.Pullingandmisuseofthepowersupplycordcanresultindamagetotheunitandcauseelectricalshock.

2 Be careful not to expose your body directly totheoutletair fora long time. Itmayaffectyourphysicalconditions.

3 When using the air/air heat pump for infants,children, elderly, bedridden, or disabledpeoplemakesuretheroomtemperatureissuitableforthoseintheroom.

4 Never insert objects into the unit. Insertingobjectscanresultininjuryduetothehighspeedrotationofinternalfans.

5 Groundtheair/airheatpumpwithoutfail.Donotconnect the groundingwire to gas pipe, waterpipe,lightningrodortelephonegroundingwire.Incompletegroundingmaycauseelectricshock.

6 If anything is abnormal with the air/air heatpump (ex. aburning smell), stop theoperationimmediatelyandturnthecircuitbreakerOFF.

7 The appliance shall be installed in accordancewithnationalwiringregulations. Impropercableconnection can cause the power supply cord,plug and the electrical outlet to overheat andcausefire.

8 If the supply cord is damaged, it must bereplaced by the manufacturer or its serviceagent or a similarly qualified person in orderto avoid a hazard. Use only the manufacture-specifiedpowercordforreplacement.

IMPORTANT SAFETY INSTRUCTIONS

WAAIU6_en.indd 1 2012-5-31 10:50:47

Page 4: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

2

PART NAMES

INDOOR UNIT

1 Inlet(Air)

2OpenPanel

3 AirFilter

4 AUXButton

5 ReceiverWindow

6 PowerSupplyCord

7 VerticalAdjustmentLouvre

8 HorizontalAdjustmentLouvre

9 Outlet(Air)

10 RemoteControl

11 PLASMACLUSTERLamp(blue)

12 OPERATIONLamp(green )

13 TIMERLamp(orange )

14 FULLPOWERLamp(green )

15 SELFCLEANLamp(green )

OUTDOOR UNIT16 Inlet(Air)

17 RefrigerantTubeandInterconnect-ingCord

18 DrainageHose

19 Outlet(Air)

NOTE:Actual units might vary slightly fromthoseshownabove.

1

2

3

4

5

6

7

8

9

10

15

14

13

12

11

19

18

17

16

WAAIU6_en.indd 2 2012-5-31 10:50:48

Page 5: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

3

REMOTE CONTROL

1 TRANSMITTER2 DISPLAY(LiquidCrystalDisplay)3 PLASMACLUSTERButton4 DISPLAYButton5 ON/OFFButton6 THERMOSTATButton7 FULLPOWERButton8 PROGRESSIVEAIRFLOWButton9 MODEButton10 TIMERONButton(forsettingthetimer)11 TIMEROFFButton(forsettingthetimer)12 ONE-HOUROFFTIMERButton13 TIMEADVANCEButton14 TIMEREVERSEButton15 SELFCLEANButton16 TIMERSET/CANCELButton17 10˚CButton18 SWINGButton( :horizontaldirection)19 CLOCKButton20 FANButton21 SWINGButton( :verticaldirection)22 Indicatesbatterycompartmentisbelowthismark

L.C.D. REMOTE CONTROL DISPLAY21 PROGRESSIVEAIRFLOWSymbol22 SELFCLEANSymbol23 PLASMACLUSTERSymbol24 MODESymbols :AUTO :COOL

:HEAT :DRY

25 ThermostatsettingforAUTOandDRYmodes26 TEMPERATUREIndicator27 TRANSMITTINGSymbol28 FULLPOWERSymbol29 FANSPEEDSymbols :AUTO :LOW

:HIGH :SOFT

30 TIMERONIndicator/CLOCK Indicatestheontimerpresettimeorcurrenttime.31 TIMEROFFIndicator Indicates thepreset time foroff timerorone-houroff

timer.

7891011

1213141516171819202122

21

22

23

24

25

26

27

28

29

30

31

6

543

2

1

WAAIU6_en.indd 3 2012-5-31 10:50:49

Page 6: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

4

SET CURRENT CLOCK TIMEThere are two clock modes: 12-hour mode and24-hourmode.Example:5o’clockintheafternoon Clock Display 12-hourmode PM5:00 24-hourmode 17:00

1 To set to the 12-hour mode, press the CLOCK button once in the first step.

To set to the 24-hour mode, press the CLOCK button twice in the first step.

2 Press the TIME ADVANCE or REVERSE button to set the current time.

•Keep the button pressed to advance orreversethetimedisplayquickly.

3 Press the SET/C button. • Thecolon(:)blinks to indicate that theclock

isfunctioning.

NOTE:• Thecurrent timecannotbesetwhenthetimer isoperating.

LOADING BATTERIESUsetwosize-AAA(R03)batteries.

1 Remove the remote control cover.

2 Insert batteries in the compartment, making sure the ± and — polarities are correctly a lign ed.

• The display indicates “AM 6:00” whenbatteriesareproperlyinstalled.

3 Reinstall the cover.

Remotecontrolcover

NOTE:• Thebatterylifeisapproximatelyoneyearinnormaluse.

•When you replace the batteries, always changebothbatteries,andmakesure theyare thesametype.

• If the remote control does not operate properlyafterreplacingthebatteries,takeoutthebatteriesandreinstallthemagainafter30seconds.

• If you will not be using the unit for a long time,removethebatteriesfromtheremotecontrol.

HOW TO USE THE REMOTE CONTROLPoint the remote control towards the unit’s signalreceiverwindowandpress thedesiredbutton.Theunitgeneratesabeepwhenitreceivesthesignal.•Make sure there is no curtain or other objectbetweentheremotecontrolandtheunit.

• Theremotecontrolcansendsignalsfromupto7metresaway.

CAUTION:• Donotallowthesignalreceiverwindowtoreceivestrongdirectsunlight,sinceitcanadverselyaffectits operation. If the signal receiver window isexposedtodirectsunlight,closeacurtaintoblockthelight.

• Using a fluorescent lamp with a quick starter inthesameroommayinterferewithtransmissionofthesignal.

• The unit can be affected by signals transmittedfrom the remote control of a television, VCR orotherequipmentusedinthesameroom.

• Donot leavetheremotecontrol indirectsunlightornearaheater.Also,protecttheunitandremotecontrol from moisture and shock which candiscolourordamagethem.

USING THE REMOTE CONTROL

231

+

WAAIU6_en.indd 4 2012-5-31 10:50:49

Page 7: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

5

TIPS ON SAVING ENERGY

Below are some simple ways to save energy when you use your air/air heat pump.

SET THE CORRECT TEMPERATURE•Settingthethermostat1°Chigherthanthedesiredtemperature in the COOL mode and 2°C lowerin the HEAT mode will save approximately 10percentinpowerconsumption.

•Setting the temperature lower than necessaryduring cooling operation will result in increasedpowerconsumption.

BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS•Blocking direct sunlight during cooling operationwillreducepowerconsumption.

•Close thewindowsanddoorsduringcoolingandheatingoperations.

SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATIONKEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATIONMAKE MOST OF THE TIMER OFF FUNCTIONDISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME• The indoorunitstill consumesasmallamountofpowerwhenitisnotoperating.

AUXILIARY MODE

Use this mode when the remote control is not available.

TO TURN ONLift the open panel of the indoor unit and press the AUX button.• The greenOPERATION lamp ( ) on the unitwill light and the unit will start operating in theAUTOmode.

•ThefanspeedandtemperaturesettingaresettoAUTO.

TO TURN OFFPress the AUX button again.• The greenOPERATION lamp ( ) on the unitwillturnoff.

AUX

NOTE:• If the AUX button is pressed during normaloperation,theunitwillturnoff.

WAAIU6_en.indd 5 2012-5-31 10:50:49

Page 8: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

6

BASIC OPERATION

TIPS ABOUT AUTO MODE

(Example:1°Chigher)

C

(Example:2°Clower)

C

253

1

4

1 Press the MODE button to select the operation mode.

AUTO HEAT COOL DRY

2 Press the ON/OFF button to start operation.

• The greenOPERATION lamp ( ) on theunitwilllight.

3 Press the THERMOSTAT button to set the desired temperature.

AUTO/DRY MODE• The temperature can be changed in 1°C in-crements within the range of 2°C higher to2°Clowerfromthetemperatureautomaticallydeterminedbytheair/airheatpump.

COOL/HEAT MODE • The temperature can be set within the

rangeof18to32°C.

4 Press the FAN button to set the desired fan speed.

AUTO SOFT LOW HIGH

• IntheDRYmode,thefanspeedispresettoAUTOandcannotbechanged.

5 To turn off the unit, press the ON/OFF button again.

• The greenOPERATION lamp ( ) on theunitwillturnoff.

IntheAUTOmode,thetemperaturesettingandmode are automatically selected according totheroomtemperatureandoutdoortemperaturewhentheunitisturnedon.Modes and Temperature Settings

Thefiguresin()aretemperaturesettings

During operation, if the outdoor temperaturechanges, the temperature settings will auto-maticallyslideasshowninthechart.

AUTO CHANGEOVERDuring seasons when you need COOLING atdaytimeandHEATINGat night, or if the roomtemperature should become extremely higherthan the temperature setting, due to supple-mentary heating equipment, themodewill au-tomatically switch between HEAT and COOLmode to keep the comfortable room tempera-ture.

WAAIU6_en.indd 6 2012-5-31 10:50:50

Page 9: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

7

VERTICAL AIR FLOW DIRECTION

1 Press the SWING button( ) on the re-mote control once. • Theverticaladjustmentlouvrewillswingcon-tinuously.

2 Press the SWING button( ) again when the vertical adjustment louvre is at the desired position.

• Thelouvrewillstopmovingwithintherange showninthediagram.

Adjustment range

COOLandDRYmodes HEATmode

HORIZONTAL AIR FLOW DIRECTION

1 Press the SWING button( ) on the re-mote control once.

• Thehorizontaladjustmentlouvreswillswing continuously.

2 Press the SWING button( ) again when the horizontal adjustment louvres are at the desired position.

NOTE:• Theadjustedpositionwillbememorizedandwillbe automatically set to the same position whenoperatedthenexttime.

• The adjustment range is narrower the SWINGrangeinordertopreventcondensationfromdrip-ping.

CAUTION:Neverattempttoadjustthelouvresmanually.• Manualadjustmentof the louvrescancause theunittomalfunction.

• WhentheverticaladjustmentlouvreispositionedatthelowestpositionintheCOOLorDRYmodeforanextendedperiodoftime,condensationmayresult.

ADJUSTING THE AIR FLOW DIRECTION

12

12

WAAIU6_en.indd 7 2012-5-31 10:50:51

Page 10: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

8

Press the PROGRESSIVE AIRFLOW button during cooling or dry operation when you do not want to feel cold air. Vertical adjustment louvre is set obliquely upward to deliver cool air to the ceiling.Press the button during heating operation. Vertical adjustment louvre is set downward to deliver the warm air down to the floor.

1 During operation, press the PROGRESSIVE AIRFLOW button.

• Theremotecontrolwilldisplay“ ”.

TO CANCELPress the PROGRESSIVE AIRFLOW button again.

NOTE:• The PROGRESSIVE AIRFLOW set t ing iscancelledwhen you press FULLPOWERbuttonwhilePROGRESSIVEAIRFLOWisset.

• If youwantPROGRESSIVEAIRFLOWoperationin FULL POWER mode, press PROGRESSIVEAIRFLOWbuttonduringFULLPOWERoperation.

In this operation, the air/air heat pump works at the maximum power and optimum louvre direc-tion to make the room cool or warm rapidly.

1 During operation, press the FULL POWER button.

• Theremotecontrolwilldisplay“ ”. •Thetemperaturedisplaywillgooff. • ThegreenFULLPOWERlamp( )onthe

unitwilllightup. • The vertical adjustment louvre will be set

obliquelydownward.

TO CANCELPress the FULL POWER button again.•The FULL POWER operation will also be can-celled when the operation mode is changed, orwhentheunitisturnedoff.

• ThegreenFULLPOWERlamp( )ontheunitwillturnoff.

• The vertical adjustment louvre will return to theoriginaldirection.

NOTE:• Theair/airheatpumpwilloperateat“ExtraHIGH”fanspeedfor5minutes,andthenshiftto“HIGH”fanspeed.

• You can not set the temperature or fan speedduringtheFULLPOWERoperation.

• To turn off the FULL POWER lamp, press theDISPLAYbutton.

PROGRESSIVE AIRFLOW FULL POWER OPERATION

1 1

WAAIU6_en.indd 8 2012-5-31 10:50:51

Page 11: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

9

PLASMACLUSTER OPERATION

Plasmacluster Ions released into the room will reduce some airborne mold.

1 During operation, press the PLASMACLUSTER button.

• Theremotecontrolwilldisplay“ ”. • ThebluePLASMACLUSTERlamponthe

unitwilllightup.

TO CANCELPress the PLASMACLUSTER button again.• ThebluePLASMACLUSTERlampontheunitwillturnoff.

NOTE:• Use of the PLASMACLUSTER operation will bememorized,and itwillbeactivated thenext timeyouturnontheair/airheatpump.

• ToturnoffthePLASMACLUSTERlamp,presstheDISPLAYbutton.

SELF CLEAN OPERATION

SELF CLEAN operation will reduce the growth mold fungus with Plasmacluster ions, and dry inside of the air/air heat pump unit.Utilize the operation at seasonal change over terms.

1 Press the SELF CLEAN button when the unit is not operating.

•Theremotecontroldisplays“ ”. •The green OPERATION lamp ( ), the

greenSELFCLEANlamp( )andthebluePLASMACLUSTERlampontheunitwill lightup.

•Theunitwillstopoperationafterfortyminutes.

TO CANCELPress the SELF CLEAN button.Alternatively, turn the unit off by pressing the ON/OFF button.• The green OPERATION lamp ( ) , thegreen SELF CLEAN lamp ( ) and the bluePLASMACLUSTERlampontheunitwillturnoff.

NOTE:• You cannot set the temperature, fan speed, airflow direction or timer setting during the SELFCLEANoperation.

• Moldfungusalreadygrowncannotbeeliminatedbythisoperation.

1

1

• To turn off the PLASMACLUSTER lamp,presstheDISPLAYbutton.

2 If you pressed the button while unit is not in operation, Plasmacluster operation starts in fan only mode.

2

WAAIU6_en.indd 9 2012-5-31 10:50:52

Page 12: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

10

ONE-HOUR OFF TIMER

When the ONE-HOUR OFF TIMER is set, the unit will automatically turn off after one hour.

1 Press the ONE-HOUR OFF TIMER button.

• Theremotecontroldisplays“ ”. • The orange TIMER lamp ( ) on the unit

willlightup. • Theunitwillstopoperatingafteronehour.

TO CANCEL Press the TIMER CANCEL (SET/C) button. • The orangeTIMER lamp ( ) on the unit

willturnoff. Alternatively, turn the unit off by pressing

the ON/OFF button. • ThegreenOPERATIONlamp( )andthe

orange TIMER lamp ( ) on the unit willturnoff.

NOTE:•The ONE-HOUR OFF TIMER operation haspr ior i ty over TIMER ON and TIMER OFFoperations.

• If the ONE-HOUR OFF TIMER is set while theunit is not operating, theunitwill operate for anhourattheformerlysetcondition.

• If you wish to operate the unit for another hourbeforetheONE-HOUROFFTIMERisactivated,press theONE-HOUROFFTIMERbuttonagainduringoperation.

• IfTIMERONand/orTIMEROFFareset,TIMERCANCELbuttoncancelseverysetting.

TIMER OPERATION

TIMER OFF

1 Press the TIMER OFF ( ) button.

2 The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE button to set the desired time.

(Thetimecanbesetin10-minuteincrements.)

3 Point the remote control at the receiver window on the unit and press the TIMER SET (SET/C) button.

• TheorangeTIMERlamp( )ontheunitwill light.

• Theunitwillgenerateabeepwhenitreceives thesignal.

TIPS ABOUT TIMER OFF OPERATIONWhentheTIMEROFFmodeisset,thetemperaturesettingisautomaticallyadjustedtopreventtheroomfrom becoming excessively hot or too cold whileyou sleep. (Auto Sleep function) The Auto SleepfunctionwillnotactivateduringtheAUTOmode.

COOL/DRYMODE:• One hour after the timer operation begins,the temperature setting rises 1°C higher thanthe original temperature setting and will thenshutdowncompletelyatthetimeroffsetting.

HEATMODE:• One hour after the timer operation begins,the temperature setting drops 3°C lower thanthe original temperature setting and will thenshutdowncompletelyatthetimeroffsetting.

123

1

CANCEL

WAAIU6_en.indd 10 2012-5-31 10:50:52

Page 13: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

11

TIMER ON

1 Press the TIMER ON ( ) button.

2 The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE button to set the desired time.

(Thetimecanbesetin10-minuteincrements.)

3 Point the remote control at the receiver window on the unit and press the TIMER SET (SET/C) button.

• The orange TIMER lamp ( ) on the unitwilllight.

• Theunitwillgenerateabeepwhenitreceivesthesignal.

4 Select the operation condition.

NOTE:• Theunitwillturnonpriortothesettimetoallowtheroomtoreachthedesiredtemperaturebytheprogrammedtime.(Awakingfunction)

COMBINED USE OF ON AND OFF TIMERSYou can use the ON and OFF timers in combination.

Example:To stop operation at 11:00 p.m. and resumeoperation to bring the room temperature to thedesiredlevelby7:00a.m.

1 Set the TIMER OFF to 11:00 p.m. during operation.

2 Set the TIMER ON to 7:00 a.m. Thearrow ( or ) between theTIMERONindicator and the TIMEROFF indicator showswhichtimerwillactivatefirst.

NOTE:• You cannot program the ON-TIMER andOFF-TIMER to operate the unit at differenttemperaturesorothersettings.

• Either timercanbeprogrammedtoactivatepriortotheother.

TO CANCEL TIMER MODEPress the TIMER CANCEL (SET/C) button.• TheorangeTIMERlamp( )ontheunitwillturnoff.

• The current clock time will be displayed on theremotecontrol.

NOTE:• If anyTIMERON,TIMEROFF andONE-HOUROFFTIMERare set, theTIMERCANCELbuttoncancelsallsettings.

TO CHANGE TIME SETTINGCancel the TIMER setting first, then set it again.

1

23

Beforesettingthetimer,makesuretheclockisproperlysetwiththecurrenttime.

CANCEL

4

WAAIU6_en.indd 11 2012-5-31 10:50:53

Page 14: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

12

INDOORTEMP. OUTDOORTEMP.COOLING

upperlimit 32˚C 43˚C lowerlimit 21˚C –10˚C

HEATING upperlimit 27˚C 24˚C

lowerlimit – –20˚C

•Thebuilt-inprotectivedevicemaypreventtheunitfromoperatingwhenusedoutofthisrange.

•CondensationmayformontheairoutletiftheunitoperatescontinuouslyintheCOOLorDRYmodewhenhumidityisover80percent.

ADDITIONAL NOTES ON OPERATION

OPERATING TEMPERATURE RANGE

WHEN POWER FAILURE OCCURSThis air/air heat pump has a memory function tostoresettingswhenapowerfailureoccurs.Afterpowerrecovery, theunitwillautomatically re-start inthesamesettingswhichwereactivebeforethepowerfailure,exceptfortimersettings.If the timerswere set before a power failure, theywillneedtobere-setafterpowerrecovery.

PREHEATING FUNCTIONIntheHEAToperation,theindoorfanmaynotstartfortwotofiveminutesaftertheunit isturnedontopreventcoldairfromblowingoutoftheunit.

DE-ICING FUNCTION•When ice forms on the heat exchanger in theoutdoor unit during the HEAT operation, anautomaticde-icerprovidesheat forabout5 to10minutes to remove the ice. During de-icing, theinsideandoutsidefansstopoperating.

•Afterde-icingiscompleted,theunitautomaticallyresumesoperationintheHEATmode.

HEATING EFFICIENCY• The unit employs a heat pump that draws heatfromtheoutsideairandreleasesitintotheroom.The outside air temperature therefore greatlyaffectstheheatingefficiency.

• If the heating efficiency is reduced due to lowoutsidetemperatures,useanadditionalheater.

• Ittakestimetowarmupandheattheentireroombecauseoftheforcedaircirculationsystem.

10°C OPERATION

Heating operation with 10°C set temperature will be performed.

1 Press the MODE button and select HEAT mode.

2 Press the ON/OFF button to start HEAT operation.

3 Press the 10°C button. • Theremotecontrolwilldisplay“10°C”.

TO CANCELPress the 10°C button again.• 10°C operation will also be cancelled when theoperation mode is changed, or when the unit isturnedoff.

NOTE:• 10°CoperationwillnotbeavailableduringAUTOmodeoperation.

2

13

DISPLAY BUTTONPress theDISPLAYbuttonwhen the lampson theunitaretoobright.(TheredOPERATIONlampandtheorangeTIMERlampcannotbeturnedoff.)

During operation, press the DISPLAY button.• The blue PLASMACLUSTER lamp and/or thegreenFULLPOWERlamp()willturnoff.

TO LIGHT UPPresstheDISPLAYbuttonagain.

1

WAAIU6_en.indd 12 2012-5-31 10:50:53

Page 15: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

13

MAINTENANCE AFTER AIR/AIR HEAT PUMP SEASON

1 Operate the unit in the SELF CLEAN operation to allow the mechanism to thoroughly dry.

2 Stop the operation and unplug the unit. Turn off the circuit breaker, if you have one exclusively for the air/air heat pump.

3 Clean the filters, then reinstall them.

MAINTENANCE BEFORE AIR/AIR HEAT PUMP SEASON

1 Make sure that the air filters are not dirty.

2 Make sure that nothing obstructs the air inlet or outlet.

CHANGING THE AIR PURIFYING FILTER

Thefiltersshouldbechangedevery3~6months

1 Remove the air filters.

2 Change the air purifying filters. 1 Takeofftheoldairpurifyingfiltersfromthe

airfilters. 2 Set the new air purifying filters, under the

filterstopperslocatedontheairfilters.

3 Reinstall the air filters.

NOTE:• The dirty air purifying filters are not washablefor reuse. The new filters are available at yournearestdealer.

Disposal of FiltersPleasedisposeof replacedfiltersaccording to thelocaldisposallawsandregulations.AIRPURIFYINGfiltermaterialsFilter:PolypropyleneFrame:Polyester

MAINTENANCE

Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance.

CLEANING THE UNIT AND THE REMOTE CONTROL•Wipethemwithasoftcloth.•Do not directly splash or pour water on them. Itcancauseelectricalshockorequipmentdamage.

•Do not use hot water, thinner, abrasive powdersorstrongsolvents.

Filterstopper5 Reinstall the air purifying filters.(If used.)

6 Reinstall the filters. 1 Reinstallthefiltersintheoriginalpositions.

2 Closetheopenpanel. 3 Push the arrow-marked of the panel firmly

tolockitinplace.

3 Take off the air purifying filters from the air filters.(If used.)

4 Clean the filters.Use a vacuum cleaner to remove dust. If thefiltersaredirty,washthemwithwarmwaterandamilddetergent.Dryfiltersintheshadebeforereinstalling.

(Option: PART CODE CFiL-A124JBKZ)

(Option: PART CODE CFiL-A124JBKZ)

CLEANING THE FILTERSTheairfiltersshouldbecleanedeverytwoweeks.

1 Turn off the unit.

2 Remove the filters. 1 Lifttheopenpanel.

2 Push the air filters up slightly to unlockthem.

3 Pulltheairfiltersdowntoremovethem.

AIRPurifyingFilters

WAAIU6_en.indd 13 2012-5-31 10:50:54

Page 16: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

14

The following conditions do not denote equip-ment malfunctions

UNIT DOES NOT OPERATEThe uni t wi l l not operate i f i t is turned onimmediately after it is turned off. The unit will notoperate immediately after the mode is changed.This is to protect the internalmechanisms.Wait 3minutesbeforeoperatingtheunit.

UNIT DOES NOT SEND OUT WARM AIR Theunitispreheatingorde-icing.

ODORSCarpetandfurnitureodorsthatenteredintotheunitmaybesentoutfromtheunit.

CRACKING NOISETheunitmayproduceacrackingnoise.Thissoundis generated by the friction of the front panel andother componentsexpandingor connectingdue toatemperaturechange.

A LOW BUZZING NOISE EMITTEDThisisasoundemittedwhentheunitisgeneratingPlasmaclusterions.

SWISHING NOISEThe soft, swishing noise is the sound of therefrigerantflowinginsidetheunit.

WATER VAPOUR• In the COOL and DRY operation, water vapourcansometimesbeseenattheairoutletduetothedifferencebetweentheroomair temperatureandtheairdischargedbytheunit.

• IntheHEAToperation,watervapourmayflowoutoftheoutdoorunitduringde-icing.

THE OUTDOOR UNIT DOES NOT STOPAfter stopping the operation, the outdoor unit willrotate its fan for about aminute to cool down theunit.

ODOR EMITTED FROM THE PLASMACLUSTER AIR OUTLETThis is the smel l of ozone generated fromthe Plasmacluster Ion generator. The ozoneconcentration is very small, posing no adverseeffectonyourhealth.Theozonedischargedintotheairrapidlydecomposes,anditsdensityintheroomwillnotincrease.

If the unit appears to be malfunctioning, check the following points before calling for service.

IF THE UNIT FAILS TO OPERATEChecktoseeifthecircuitbreakerhastrippedorthefusehasblown.

IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY•Checkthefilters.Ifdirty,cleanthem.•Check the outdoor unit to make sure nothing isblockingtheairinletoroutlet.

•Checkthethermostatispropersetting.•Makesurewindowsanddoorsareclosedtightly.•Alargenumberofpeopleintheroomcanpreventtheunitfromachievingthedesiredtemperature.

•Check whether any heat-generating appliancesareoperatingintheroom.

IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL•Checkwhether the remotecontrolbatterieshavebecomeoldandweak.

•Try to send the signal again with the remotecontrol pointed properly towards the unit’s signalreceiverwindow.

•Check whether the remote control batteries areinstalledwiththepolaritiesproperlyaligned.

Please call for service when OPERATION lamp, TIMER lamp and/or PLASMACLUSTER lamp on the unit blink.

BEFORE CALLING FOR SERVICE

WAAIU6_en.indd 14 2012-5-31 10:50:54

Page 17: SPLIT TYPE GREEN SOURCE AIR / AIR HEAT PUMP OPERATION …

TIN

SEA

751J

BRZ

12

C- T

H

1 

  

Ope

ratio

n M

anua

l Gre

enso

urce

air

to a

ir 20

12/0

3 en

8-7

16-1

15-3

59

Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd.Cotswold Way, Warndon,

Worcester, WR4 9SWTel: 01905 754624 Fax: 01905 754619

WAAIU6_cover.indd 3 2012-4-12 13:15:38