REI-LUX 3D structural stability measurements SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ANCHORED STRUCTURES The latest in structural stability testing : Nature, with its variable wind loads on columns is equalled... ...by our sophisticated static and dynamic 3D-wind- load simulation system with decades of development history. We measure a column’s natural response to accurate wind simulation as this automatically provide realistic structural stability data. ACTION REACTION World patent registration: PCT/EP 2012/054417

SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ... - rei-lux… · REI-LUX 3D structural stability measurements ... Using the belt as a counter bearing prevents any overloading of the

Embed Size (px)

Citation preview

Page 1: SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ... - rei-lux… · REI-LUX 3D structural stability measurements ... Using the belt as a counter bearing prevents any overloading of the

REI-LUX 3D structural stabil ity measurements

SPECIALISED SERVICES FOR COLUMNSAND SIMILAR ANCHORED STRUCTURES

The latest instructural stability testing:

Nature, with its variable wind loadson columns is equalled...

...by our sophisticated static and dynamic 3D-wind-load simulation system with decades of development history.

We measure a column’s natural responseto accurate wind simulation as this automatically provide realistic structural stability data.

ACTION

REACTION

World patent registration: PCT/EP 2012/054417

Page 2: SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ... - rei-lux… · REI-LUX 3D structural stability measurements ... Using the belt as a counter bearing prevents any overloading of the

SPECIALISED SERVICES FOR COLUMNSAND SIMILAR ANCHORED STRUCTURES.

REI-LUX Bernhard-Hahn-Straße 30a - 41812 Erkelenz - Tel 02431/8051 -85 -86 - Fax -89 - eMail: [email protected] - www.rei-lux.de

REI-LUX testing, measuring and process technology

Our services cover most measurement and test specifications for test and safety-related objects such as columns, support structures and traffic management bridges. Our core competency lies in 3D structural-stability measurements for columns and similar anchored structures.

This precise, gentle and pioneering REI-LUX measuring and testing technology - which is working statically and dynamically - is used in Europe since 1985 with success.

At REI-LUX head-office provides ample space for the wide range of services we develop and provide, but also satisfies our high requirements for consistent development of our services and products, advisory services, ‘live’, quality assurance, prompt delivery and thorough after-sales service.

Our job is to find the right solution for your requirements, however complex.

Your REI-LUX team VA-Masttüren

1|7

ww

w.r

ei-

lux

.de

Page 3: SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ... - rei-lux… · REI-LUX 3D structural stability measurements ... Using the belt as a counter bearing prevents any overloading of the

2|7

ww

w.r

ei-

lux

.de

ww

w.r

ei-

lux

.de

2|7

REI-LUX Bernhard-Hahn-Straße 30a - 41812 Erkelenz - Tel 02431/8051 -85 -86 - Fax -89 - eMail: [email protected] - www.rei-lux.de

REI-LUX CORE COMPETENCY:STRUCTURAL STABILITY MEASUREMENTS

All-round precision measurements of structural stability in masts

The masts are subjected to a mechanical stress test taking into account international rules and recommendations of standards EN 40, Euro code 1 and Euro code 3. All the movements of the mast are recorded at two measuring points on our 3D measuring camera to ensure a non-destructive and careful examination and be able to give meaningful analysis.

A particular advantage of the REI-LUX process is its force-introduction concept achieved by belt-power transmission. Using the belt as a counter bearing prevents any overloading of the base. Especially for concrete columns, we have developed a material-conserving method that uses partial force distribution to minimize surface stresses in the concrete.

Test without disabilities and environmental impacts

Our compact test devices enable us to reach masts even in inaccessible places without obstructing traffic, disturbing nature or polluting the environment with exhaust emissions (playgrounds, sports fields, pedestrian precincts, park lanes).

Successful application world-wide

The REI-LUX methods are well-known in Europe, Australia and New Zealand and are also patented Europe-wide. The REI-LUX method is successfully used by our licensees in Benelux, Great Britain, France/Morokko, Austria and Hungary, Australia and New Zealand.

Accreditation

Our company in Germany is according to DIN EN ISO / IEC 17025:2005 with 3 test load methods in conjunction with our testing and 3D measuring software as test laboratory:    

Static and dynamic (impulse excitation) Mast examination

Dynamic Mast examination (frequency excitation on rotation)

Static Structural system testing

in conjunction with AA-01 / 2006-05 / test and measurement software

Page 4: SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ... - rei-lux… · REI-LUX 3D structural stability measurements ... Using the belt as a counter bearing prevents any overloading of the

Lighting columns Floodlighting columns Traffic signal poles Structures Safety fences, balustrades Timber/wooden poles

Applications:

3|7

REI-LUX 3D STABILITY MEASUREMENTSI. Static dynamic pole structure testing

Mobile testing technology for mast materials and mast construction variants up to 20 m structural height, as well as support structures, anchors and foundations can be tested for material strength, material fatigue, oscillatory behaviour and stability.

European Patent: EP 1 416 259 A2

Dual measuring point Patent: DE 100 08 2025

ww

w.r

ei-

lux

.de

REI-LUX Bernhard-Hahn-Straße 30a - 41812 Erkelenz - Tel 02431/8051 -85 -86 - Fax -89 - eMail: [email protected] - www.rei-lux.de

F1

F2

Ground laser

3D measuring camera

= critical column sections registered by the measuring system

Column laser

Textile belt actingas stop

Test loadsegmentation

Benefits

Our 3D structural stability measurement is legally and technically recognized and provides clear protocolled yes/no stability statements to certify the stability of anchored column systems.

Special feature: Material-conserving test-load distribution is applied using partial-pressure technology and the latest sensor techniques also using sophisticated software technology.

Page 5: SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ... - rei-lux… · REI-LUX 3D structural stability measurements ... Using the belt as a counter bearing prevents any overloading of the

REI-LUX 3D STABILITY MEASUREMENTS

Applicable for masts up to 50 m height:

High masts, special masts Lattice towers, antenna masts Traffic poles with bracket arms Engineering structures Fondation blocks, object anchors Travers beams, architectural objects Playground apparatus, etc.

4|7

II. Rotation dynamic column structure testing

European Patent:EP 1 630 537 B1

Measuring element

The column movements either by Multidimensional Accelerometers (Patent DE 100 62 794) or by Camera and laser sensors(Dual Point Patent DE 100 08 2025) recorded.

ww

w.r

ei-

lux

.de

REI-LUX Bernhard-Hahn-Straße 30a - 41812 Erkelenz - Tel 02431/8051 -85 -86 - Fax -89 - eMail: [email protected] - www.rei-lux.de

Portable technologgy for non-destructive load testing: constantly increasing rpm are used to generate a continuously rising frequency, whereby all frequencies and dynamic stability risks in the column system are determined using microstructure analysis (fast Fourier analysis - FFT).

Ground laser

Column laser

3D measuring camera

TEST LOADFrequencygenerator

= critical column sections registered by the measuring system

Special feature:Compactly designed testing system, non-obstructive action, complete column and support structures are included in the measurement, automatic testing and measuring process.

Page 6: SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ... - rei-lux… · REI-LUX 3D structural stability measurements ... Using the belt as a counter bearing prevents any overloading of the

REI-LUX 3D STABILITY MEASUREMENTS

What do we inspect?

Massive structures on masonry concrete, reinforced and prestressed concrete are to:Examined cracks, bulges, moisture penetration, damaged joints, efflorescence, rust stains, cavities, chips and other changes by visual inspections and possibly by Photos.

What we are testing and measuring?

Catinery structure (tensile strength of ropes, clamps) Cross-section reduction of wall hooked and eye joints Wall hooks and roof pole stability Dynamic stability of the Catinery structure

III. Static catinery structure testing

Application

Structures of overhead tram cables, supporting structures of lighting systems, wall hooks of catinerys, ropes, wall hooked up lighting systems and hanging traffic lights.

Clamp withLaser Module

“BYPASS” (frog terminals)DFP manometer test load

and suspension load display

3D cameraand analysis

Laser beam

European patent:EP 11180046.2

5|7

In order to determine the actual hanging catinery load (e.g. over street hanging lamps and traffic lights on wire rope) precisely, it will be initially relieved though a “BYPASS” (frog terminals). Then a reference test load (approx.180 kg), which is specified by the customer, will be inserted by a hydraulic pulling cylinder.

ww

w.r

ei-

lux

.de

REI-LUX Bernhard-Hahn-Straße 30a - 41812 Erkelenz - Tel 02431/8051 -85 -86 - Fax -89 - eMail: [email protected] - www.rei-lux.de

Special featureStatic test of tensile sample without facade support

Page 7: SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ... - rei-lux… · REI-LUX 3D structural stability measurements ... Using the belt as a counter bearing prevents any overloading of the

SPECIAL SERVICES AND PRODUCTS

6|7

Upgrading of steel columns

Reinforcing the static or the stability of steel and aluminium columns. Also applicable to severely debilitated, corroded masts.Savings on resources and costs for lighting columns – lower part.

To level columnTo align columnTo set column straight

Similar to the mast production a cold deformation is applied, It is also possible in case of damaged poles, without weakening them. Utilize high savings potential and 5-year warranty.

Stainless steel column door

The doors come standard with delivered two rugged M10 cam bolts and a sturdy, rear-mounted 5x20 mm V2A retention tab. Also custom made and special constructions.

Security screws with vandalism and access protection

Corrosion resistant material.Available thread sizes: M5 to M12. Customized screw for retrofitting older column doors available.

Screws applications:Poles, solar panels, lights, tunnel lights, fences, transformer stations, bollards, bins, playground equipment, etc.

Optional countersink

Optionalscrew

Standard screw

Standard eccentric screw

Eccentric screwdriver

ww

w.r

ei-

lux

.de

REI-LUX Bernhard-Hahn-Straße 30a - 41812 Erkelenz - Tel 02431/8051 -85 -86 - Fax -89 - eMail: [email protected] - www.rei-lux.de

Page 8: SPECIALISED SERVICES FOR COLUMNS AND SIMILAR ... - rei-lux… · REI-LUX 3D structural stability measurements ... Using the belt as a counter bearing prevents any overloading of the

INTERNATIONAL PARTNERS

7|7 REI-LUX GermanyREI-LUX Prüf- Mess- VerfahrenstechnikVerfahrenstechnik

Bernhard-Hahn-Straße 30a41812 Erkelenz

Tel.: +49 (0) 2431/8051 -85 Telefax: +49 (0) 2431/8051 -89eMail: [email protected] : www.rei-lux.de

REI-LUX Netherlands REI-LUX Benelux b.v.Rob [email protected]

REI-LUX Belgie P/A: REI-LUX Benelux b.v. www.rei-lux.nl [email protected]

REI-LUX UK REI -LUX UK Limited,Appt 12 , Wilmslow ViewHenbury Road Handforth, SK9 3PJ EnglandDean Naylor: 0044 7795 117 386Mark Beaumont: 0044 7925 923 941Internet: www.reilux.uk

REI-LUX Customer Service GermanyGert Lindenberg, Dipl.-Ing. (FH)

Vagenerau Weg 2683052 Bruckmühl

Tel.: +49 (0) 8062 804 643Fax: +49 (0) 8062 804 642Mobile. +49 (0) 163 531 3395eMail: [email protected]

REI-LUX Austria / Hungary ELIN GmbH & Co KGManfred Kaindl www.elin.com [email protected]

REI-LUX France / Morocco Rei-Lux ContrôlesAlexandre Kiss, 111 Avenue de la Forêt85270 Saint Hilaire de RiezTelefon: +33 (0)4 73 16 90 83Fax: +33 (0)4 73 36 31 82Internet: www.rei-lux.fr

REI-LUX Australia / New Zealand REI-LUX Australia Jamie Flintoff [email protected]

REI-LUX Europe - Central building in Erkelenz, Germany

ww

w.r

ei-

lux

.de

REI-LUX Bernhard-Hahn-Straße 30a - 41812 Erkelenz - Tel 02431/8051 -85 -86 - Fax -89 - eMail: [email protected] - www.rei-lux.de

REI-LUX testing, measuring and process technology