13
ZBR Voltage stabilisation 21.06.2007 1 Merz, dept. TSFF MAN Nutzfahrzeuge Group Voltage stabilisation

Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007 1Merz, dept. TSFFMAN Nutzfahrzeuge Group

Voltage stabilisation

Gianotti
Stamp
Page 2: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 2Merz, dept. TSFF

Production figures for 2006

7 370 buses 81 776 trucks

Page 3: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 3Merz, dept. TSFF

Voltage stabilisation

� Nominal voltage: 24V d.c.Typical alternator voltage: 28.5V d.c. (Tk -14mV/K)

� The Central On-board Computer (ZBR, the central unit for controlling the lighting, senses the operating voltage and regulates i.a. the low beam.

� If the operating voltage is > 26.8 V, the effective voltage of the low beamis regulated down to 26.8 (+/- 0.2) Veff. Tests during nighttime drivingshowed that the reduction of the operating voltage to this value is not visible to the driver.

� � If the effective operating voltage is limited to 26.8 V the service life of the H7 bulb used is prolonged by a factor of 2 to 3. Burning lives of over2000 h have been achieved.

Page 4: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 4Merz, dept. TSFF

Alternator regulator curve

Control voltage: Ub+Gen = 28.5V d.c. +/- 0,3V d.c.at nGen = 6000 rpm; IGen = 5A (stab.); Tu = 25°CTemperature compensation (TC): -14mV/K +/- 0.3mV/K

TC curve

26,5

27,5

28,5

29,5

30,5

-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100

Tu [degrees Celsius]

UB

+G

en [V

]

When the engine is running the vehicle's operating voltage does not fall below 26.8V.

Page 5: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 5Merz, dept. TSFF

Voltage stabilisation

Oscillogram of the operating voltage of the low beam controlled by the Central On-board Computer. Channel 1 (red line): Low-beam voltage : UAbbl. = 26.9VeffChannel 2 (green line): Vehicle network voltage: Ub = 30V d.c.

30V

0V

PWM frequency: 80 Hz

Page 6: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 6Merz, dept. TSFF

Voltage stabilisation

Relative dependenceof bulbs on voltage

Page 7: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 7Merz, dept. TSFF

Voltage stabilisation

Long-time test with H7 LonglifebulbOperating voltage: 29.5V d.c.Bulb voltage : 26.8V effClock frequency (PWM): 80HzCharacteristicservice life: 2170 h

H7 Longlife bulb after long-time test at 26.8V eff

Page 8: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 8Merz, dept. TSFF

Voltage stabilisation

Long-time test with H7 LonglifebulbOperating voltage: 29.5V d.c.Bulb voltage: 25.6V effClock frequency (PWM): 80HzCharacteristicservice life: 1463 h

Page 9: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 9Merz, dept. TSFF

Voltage stabilisation

ISO-Lux diagramH4- 28.0V d.c.;Hella uniform headlight,Used in F90 1983

ISO-Lux diagramH1- 28.0V d.c.;Lens headlightUsed in F2000 1994

Illumination on the test screen

Page 10: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 10Merz, dept. TSFF

Voltage stabilisation

ISO-Lux diagramH7- Longlife 28.0V d.c.;Used in TGA 2000

ISO-Lux diagramH7- Longlife 26.6V d.c.;Used in TGA, sincebegin of 2006

Illumination on the test screen

Page 11: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 11Merz, dept. TSFF

Conclusions

� There is no need for an extra light source control unit in our trucks and buses

� Lifetime of bulbs can be increased by using the functionality of our centralboard computer

� This is -at the moment- the high end solution for trucks

Page 12: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 12Merz, dept. TSFF

Thank you.

MAN Nutzfahrzeuge AGDept. TSFF

Dachauer Straße 667D-80995 München

http://www.man-trucks.com

Page 13: Spannungsregelung Abblendlicht 04062007-en · MAN Nutzfahrzeuge Group Merz, dept. TSFF ZBR Voltage stabilisation 21.06.2007 11 Conclusions There is no need for an extra light source

ZBR Voltage stabilisation 21.06.2007MAN Nutzfahrzeuge Group 13Merz, dept. TSFF

Trucknology ® delivers