Sound progress A review of homeowner feedback on noise in new homes Primary research 56

Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Sound progress A review of homeowner feedback on noise in new homes

Primary research

56

Page 2: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

© NHBC FoundationNF 56Published by IHS BRE Press on behalf of the NHBC FoundationApril 2014 ISBN 978-1-84806-373-0

NHBC FoundationNHBC HouseDavy AvenueKnowlhillMilton KeynesMK5 8FPTel: 0844 633 1000Email: [email protected]: www.nhbcfoundation.org

Follow us on Twitter @nhbcfoundation

Acknowledgments

This research was carried out by Peter Turner (NHBC).

The final report was prepared by Phil Rogers (NHBC) and Clive Turner (NHBC Foundation).

The NHBC Foundation is grateful to Dave Baker OBE, Chief Executive, Robust Details, for providing comments and insights in the development of this report.

Page 3: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Sound progress A review of homeowner feedback on noise in new homes

1NHBC Foundation Sound progress

Contents

Foreword 3

Introduction 4

Methodology 5

Findings for attached homes 6

Findings for detached homes 8

Conclusions 10

References 12

Page 4: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

The NHBC Foundation

2 NHBC Foundation Sound progress

The NHBC Foundation

The NHBC Foundation, established in 2006, provides high quality research and practical guidance to support the house-building industry as it addresses the challenges of delivering 21st century new homes. To date we have published over 50 reports on a wide variety of topics, including the sustainability agenda, homeowner issues and risk management.

The NHBC Foundation is also involved in a programme of positive engagement with the Government, academics and other key stakeholders, focusing on current and pressing issues relevant to house building.

To find out more about the NHBC Foundation, please visit www.nhbcfoundation.org. If you have feedback or suggestions for new areas of research, please contact [email protected].

NHBC is the standard-setting body and leading warranty and insurance provider for new homes in the UK, providing risk management services to the house-building and wider construction industry. All profits are reinvested in research and work to improve the construction standard of new homes for the benefit of homeowners. NHBC is independent of the Government and builders. To find out more about NHBC, please visit www.nhbc.co.uk.

The NHBC Foundation Expert Panel

The NHBC Foundation’s research programme is guided by the following panel of senior representatives from Government and industry:

Rt Hon Nick Raynsford MP Chairman of the NHBC Foundation and Expert Panel

Dr Peter Bonfield OBE Chief Executive, BRE Group

Jane Briginshaw Head of Design and Sustainability, HCA

Andrew Burke Policy Officer, National Housing Federation

Claire Curtis-Thomas Chief Executive, British Board of Agrément

Hywel Davies Technical Director, Chartered Institution of Building Services Engineers

Andrew Day Director Architecture, Design & Sustainability – New Homes and Communities, Countryside Properties (UK) Ltd

Michael Finn Design and Technical Director, Barratt Developments plc

Cliff Fudge Technical Director, H+H UK Ltd

Richard Harral Head of Technical Policy, Building Regulation and Standards Division, Department for Communities and Local Government

Neil Jefferson Director, NHBC and Chief Executive, Zero Carbon Hub

Rod MacEachrane NHBC Director (retired)

Robin Nicholson CBE Senior Partner, Cullinan Studio

Tadj Oreszczyn Professor of Energy and Environment and Director of the UCL Energy Institute, University College London

Geoff Pearce Executive Director of Regeneration and Development, Swan Housing Association

Mike Quinton Chief Executive, NHBC

Helen Saunders Group Marketing Director, Crest Nicholson plc

Steve Turner Head of Communications, Home Builders Federation

Andy von Bradsky Chairman, PRP Architects LLP

Karl Whiteman Divisional Managing Director, Berkeley Homes

Tony Woodward Managing Director, Kingerlee Homes

Neil Smith Head of Research and Innovation, NHBC and Secretary to the Expert Panel

Page 5: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Foreword

3NHBC Foundation Sound progress

Foreword

The 2003 edition of Approved Document E was launched against a backdrop of growing concern over noise transmission between adjoining homes. To address this problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for pre-completion testing that would need to be applied to 10% of all new homes. In 2004 the Robust Details scheme became available as a Government-approved alternative to pre-completion testing. Developed with the support of the industry, Robust Details are a series of high-performance construction details that, if adopted, enable separating floors and walls to meet or exceed the AD E performance standard. Since 2004 the Robust Details scheme has been increasingly used by designers and house builders as part of their housing solutions. Compliance testing shows that Robust Details are effective in delivering the performance standards set down by AD E 2003 and this has generated confidence in their use.

For the wider industry, with its increasing focus on the consumer, the key question is whether the introduction of the AD E 2003 standards, supported by the Robust Details scheme, has delivered better-performing homes in practice. To examine this question NHBC and the NHBC Foundation, have investigated and reviewed the pattern of noise problems reported by occupiers of new homes registered with NHBC since 2004. The findings from that work, summarised in this report, are very encouraging. For transmitted noise we can see a picture of gradual improvement in performance for new attached homes, from 2004, coinciding with the adoption of AD E 2003 and the availability of Robust Details. While, in this case, the true cause and effect relationship between regulatory intervention and improved performance is complex, the good outcome observed does give reassurance that close collaboration between Government, industry and academia can be effective in addressing critical challenges.

Rod MacEachrane NHBC Director (retired)

Page 6: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Introduction

4 NHBC Foundation Sound progress

Introduction

Background

During the latter part of the 20th century, noise transmitted between homes was a growing concern for homeowners and social landlords, and the subject of complaints to local government environmental health officers. In extreme cases, there were health implications for occupants subjected to noise nuisance. By the 1990s the issue had gained a high profile and a political dimension.

While many of these noise problems were associated with apartments and conversions of existing buildings to multiple-residential occupancy, some new build houses were also failing to prevent sound transmission at intrusive levels. Despite progressive tightening of the acoustic performance requirements in successive versions of Building Regulations (England and Wales) Approved Document E (AD E) Resistance to the passage of sound(1), noise transmission between homes remained a persistent problem. In response, in 2002, the Government proposed that a system of pre-completion sound testing be introduced for some types of home as a means of complying with the soon to be published AD E 2003. During the subsequent period of consultation with the industry an alternative option to pre-completion testing, Robust Details, was proposed and rapidly developed. The use of Robust Details, originally a set of 13 construction details which met more stringent acoustic performance standards, was formally accepted by Government in mid-2004 as an alternative method of complying with AD E 2003.

The portfolio of Robust Details has been steadily expanded over the years and the number of house-building plots registered with the scheme has increased rapidly. By 2010 (the last build year assessed in this research) over 58,000 homes(2) per annum were being built with Robust Details – over 70% of all attached homes under construction at that time. With Robust Details, compliance levels to AD E exceeded 99.4% in 2010(2), giving a high degree of confidence in the approach itself, and reassurance to designers and house builders that future occupants should not be troubled by noise transmitted from adjoining homes.

Purpose and scope of this research

The main aim of this NHBC Foundation research was to uncover any trends in occupant feedback of noise problems following the introduction of AD E 2003, and to test if, in practice, occupants were benefiting from the technical improvements encouraged by its introduction. The study therefore focuses particularly on noise transmission through party walls and party floors of attached homes (the AD E E1 noise category) which the Robust Details scheme was set up to address.

For evidence, the study draws on the feedback provided by occupants of new homes between 2004 and 2010. Under the terms of the NHBC Buildmark warranty, builders are liable to put right any defect or damage in the first 2 years after completion of the home, and it is this 2-year period which this research relates to. Contacts from homeowners made to NHBC relating to noise have been analysed and classified according to the type of noise and its source.

Noise between dwellings is only one sub-set of noise problems that are recognised by occupants. Other noise problems reported to NHBC include those generated by the fabric and services of the home itself, and noise transmitted between rooms. Contacts from homeowners to NHBC relating to these other sources of noise have also been reviewed in this report, which is also widened to cover feedback on detached homes.

Page 7: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Methodology

5NHBC Foundation Sound progress

Methodology

This study involved the analysis and classification of contacts to NHBC made by homeowners raising concerns related to noise during the first 2 years after occupation. The study period was from 2004 (the first full year following the introduction of AD E 2003) to 2010 (the last year for which a full set of data was available). The feedback was from homes in England and Wales.

Homeowner contacts have been classified into the following noise categories:

�� AD E E1 – airborne and impact noise transmitted from an adjoining home�� AD E E2 – airborne and impact noise transmitted within a home�� AD E E3 – reverberation of sound in communal areas of buildings�� Creaking floors �� Creaking stairs�� Water pipes and WCs�� Boilers and radiators�� Extract fans.

Some homeowner contacts were received on a few other miscellaneous issues, including noise from weather, vibration and doors. However, these occurred in extremely low numbers and for this reason have not been included in this report.

It is to be noted that the annual output of new homes across England and Wales varied considerably during the study period and the proportion of detached to attached homes also changed over time (Figure 1). For this reason homeowner contacts are expressed as a number per 1000 homes registered with NHBC.

Figure 1 Numbers of new home completions registered with NHBC in England and Wales (2004 to 2010)

During the study, two categories of noise contacts predominated (E1 noise for attached homes and creaking floors for detached houses). These categories are given more detailed consideration in this report. For comparison, contacts on the secondary sources of noise are also included. These were recorded at very low levels, often well below a value of 1 contact for every 1000 homes. While each contact should be individually investigated, such low levels of concern would probably not indicate a systemic noise problem or signal the need for a change in regulation or good practice. Increasingly careful observation should be given as the level of concern for a particular noise problem rises above 1 in a 1000 homes, particularly if there are any indications of an upward trend.

0

20000

40000

60000

80000

100000

120000

140000

160000

180000

2004 2005 2006 2007 2008 2009 2010

Com

ple

tion

s re

gis

tere

d w

ith

NH

BC

per

yea

r

Apartments

Attached houses

Detached houses

Page 8: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Findings for attached homes

6 NHBC Foundation Sound progress

Findings for attached homes

Results from this study indicate that for new attached homes (terraced and semi-detached houses and apartments) first occupied between 2004 and 2010, there has been a progressive decline in the noise-related homeowner contacts to NHBC (Figure 2). The majority of these contacts (Figure 3) are in the ‘E1’ category: noise transmission from adjoining homes.

The E1 noise category merits closer examination because minimising this noise problem for occupants was a priority for the revised guidance in AD E 2003 and for the Robust Details scheme introduced in 2004. From Figure 4 it can be seen that E1 noise contacts reduced significantly over the study period, and largely accounted for the overall reduction in noise contacts shown in Figure 2. Figure 5 shows the patterns of contacts related to other sources of noise. These were all at very low levels across the study period.

3.0

4.0

5.0

6.0

7.0

8.0

2004 2005 2006 2007 2008 2009 2010 2011 2012

Con

tact

s to

NH

BC

per

100

0 ho

mes

Year that the home was first occupied

Figure 2 Attached homes. Homeowner contacts to NHBC for all noise categories (for homes first occupied between 2004 and 2010)

E1 noise transmission (from adjoining homes) – 43%

Creaking floors – 24%

Water pipes, WCs – 10%

Boilers and radiators – 5%

Extract fans – 3%

E2 Noise transmission(within the home) – 2%

Other sources of noise – 13%

43%

24%

10%

Figure 3 Attached homes. Distribution of main types of noise contacts to NHBC (for houses first occupied between 2005 and 2010)

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012

Con

tact

s to

NH

BC

per

100

0 ho

mes

Year that the home was first occupied

All attached homesApartments Attached houses

For new homes from July 2004:pre-completion sound testing required OR option to use Robust Details

For new homes from July 2004:pre-completion sound testing required OR option to use Robust Details

Introduction of AD E 2003Introduction of AD E 2003

Figure 4 Attached homes. Homeowner contacts to NHBC on noise from adjoining properties – E1 noise (for homes first occupied between 2004 and 2010)

Page 9: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Findings for attached homes

7NHBC Foundation Sound progress

Main findings for attached homes first occupied between 2004 and 2010

�� From 2004, attached homes built in successive years, generated progressively fewer homeowner contacts related to noise problems. For attached homes first occupied in 2004, about 7 households per 1000 contacted NHBC about a noise problem. For homes first occupied in 2010, the level was down to about 4 for every 1000 households.

�� The reduction in homeowner contacts is found to be largely attributable to fewer concerns over transmission of noise from adjoining homes (the AD E E1 noise category). E1 contacts from 2010 homes (data from houses and apartments combined) were less than half those recorded for those first occupied in 2004 (Figure 4).

�� For attached houses the ongoing downward trend in E1 contacts is particularly pronounced (Figure 4). For houses first occupied in 2010, only about 1 in a 1000 households registered an ‘E1’ concern.

�� The start of the downward trend in E1 contacts coincides with new regulatory guidance in AD E 2003 and the associated launch of the Robust Details scheme in 2004. This improvement trend should be interpreted alongside the transitional arrangements for adoption of the regulatory requirements and guidance, which allows the previous AD to be used, provided plans were agreed before the introduction of the revised edition. In practice there can be a considerable lag, of some years, before all projects are finally aligned.

�� For apartments, the improvement trend with E1 contacts is less pronounced (Figure 4) perhaps reflecting the greater technical challenges associated with minimising sound transmission in this housing type. Thecontacts received suggest that a high proportion of the noise problems were associated with party floors, rather than party walls.

�� After E1 noise, creaking floors were the next most common cause of homeowner contact across the period of investigation, but for this and other sources of noise (examples shown in Figure 5) the overall level of concerns registered by homeowners was very low.

0.0

0.5

1.0

1.5

2.0

2004 2005 2006 2007 2008 2009 2010 2011 2012

Con

tact

s to

NH

BC

per

100

0 ho

mes

Year that the home was first occupied

Creaking floors

Water pipes/WCs

Boilers and radiators

E2 noise

Figure 5 Attached homes. Homeowner contacts to NHBC on other noise categories (for homes first occupied from 2004 to 2010)

Page 10: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Findings for detached homes

8 NHBC Foundation Sound progress

Findings for detached homes

Owners of detached homes were typically twice as likely to contact NHBC about noise, than those living in attached homes (Figure 6). Of the homeowner contacts received, the most common (48%) related to creaking floors (Figure 7). By definition none fall in the E1 noise category (noise transmission from adjoining homes).

In this study, contacts relating to creaking floors could be up to five times higher from owners of detached, compared to attached homes (Figure 8). Contacts relating to other sources of noise (Figure 9) were also more common from detached homeowners, typically at levels between 3 and 4 times those for attached homes.

3

5

7

9

11

13

2004 2005 2006 2007 2008 2009 2010 2011 2012

Con

tact

s to

NH

BC

per

100

0 ho

mes

Year that the home was first occupied

Detached homes

Attached homes

Figure 6 Detached homes. Homeowner contacts to NHBC on all noise categories (for homes first occupied between 2004 and 2010)

Creaking floors – 48%

Water pipes, WCs – 15%

Boilers and radiators – 9%

E2 Noise transmission(within the home) – 9%

Creaking stairs – 5%

Extract fans – 5%

Other sources of noise – 9%

48%

15%

9%

Figure 7 Detached homes. Distribution of main types of noise contacts to NHBC (for homes first occupied between 2005 and 2010)

0

1

2

3

4

5

6

7

8

2004 2005 2006 2007 2008 2009 2010 2011 2012

Con

tact

s to

NH

BC

per

100

0 ho

mes

Year that the home was first occupied

Detached homes

Attached homes

Figure 8 Detached homes. Homeowner contacts to NHBC on creaking floors (for homes first occupied between 2004 and 2010)

Page 11: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Findings for detached homes

9NHBC Foundation Sound progress

Main findings for detached homes first occupied between 2004 and 2010

�� From 2004, owners of detached homes were much more likely to contact NHBC in relation to noise issues than those living in attached homes (Figure 6). The most recent data suggests that homeowners of detached homes were 58% more likely to raise a noise issue than owners of attached homes. During the period of this study, between 8 and 12 detached households per 1000 contacted NHBC about a noise problem.

�� Overall contacts on noise from detached homes do not indicate an obvious trend (rise or fall) over time.

�� For detached houses the most common contact related to creaking floors (Figure 7). On average about 1 in every 200 detached homes registered a concern about this type of noise though this figure varied considerably across the period of study (Figure 8). Significantly, people in detached homes were 3-5 times more likely to report creaking floors than people in attached homes.

�� Contacts related to other noise types (Figure 9) were also noted to be at higher levels in detached homes, compared with attached homes, including:

– Plumbing (pipes and WCs) – Boilers and radiators – Creaking stairs – E2 (Noise transmission within the home).

For all these categories of noise, occupants of detached homes were 3 to 4 times more likely to make contact with NHBC than those living in attached homes.

Contacts related to these noise categories showed no consistent trends across the timeframe of this study, though it is possible that in the more recent years, creaking from stairs is an emerging issue.

0.0

0.5

1.0

1.5

2.0

2004 2005 2006 2007 2008 2009 2010 2011 2012

Noi

se e

nqui

ries

to

NH

BC

per

100

0 ho

mes

Year that the home was completed and first occupied

E2 noise

Creaking stairs

Water pipes/WCs

Boilers/radiators

Extract fans

Figure 9 Detached homes. Homeowner contacts to NHBC on other sources of noise (for homes first occupied between 2004 and 2010)

Page 12: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Conclusions

10 NHBC Foundation Sound progress

Conclusions

Approved Document E 2003

The key ambition for AD E 2003 was to achieve a step change in the reduction of sound transmission between adjoining homes (Requirement E1) and sound transmission within homes (Requirement E2). Since they were introduced in 2004, Robust Details (see, for example, Figures 10 and 11) have been progressively adopted by house builders as an option for meeting AD E.

AD E E1

This report shows that since 2004, occupants of new-build attached homes are reporting fewer and fewer concerns over sound transmission from adjoining properties. The downward trend in E1 homeowner contacts is striking for attached houses, indicating that excellent progress has been made in achieving this principal policy objective of AD E 2003. For apartments, although good progress has been made, the reduction in homeowner contacts is less marked (particularly after 2006) than for attached houses. This is perhaps unsurprising, given that the additional E1 elements (floors and their junctions with adjoining flanking structures) represent a more complex and technically challenging set of acoustic issues.

AD E E2

Airborne and impact noise transmitted within a home (E2 noise) is only very rarely reported (less than 1 in 5000 homes) by occupiers of attached homes. Though occupiers of detached homes made contact more frequently about E2 noise, this is still a rare concern and seemingly adequately addressed by design and construction.

Figure 10 Minimising noise transmission (AD E E1) between new homes. The cavity sock provides fire protection and insulation against flanking sound transmission Photograph courtesy Robust Details Ltd

Page 13: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Conclusions

11NHBC Foundation Sound progress

AD E E3

With apartments, contacts for E3 noise issues (reverberation of sound in communal areas) are extremely rare, suggesting that current guidance and construction quality is satisfactory.

Other noise

As well as noise categories covered by AD E, there are three other notable sources of noise that appear significant to homeowners. For creaking floors (overall representing 34% of all noise contacts) site investigations tend to show that floor decking was not adequately fixed down and, once remedied, homeowners no longer experienced problems. For water pipes and WCs, noise problems were typically associated with lack of allowance for expansion or contraction movement, and contact with rigid brackets and linings: issues that would be eliminated by following existing good practice. For the third most common problem, noise from boilers and radiators, this could largely be eliminated by adjustments to the heating system.

These three noise sources accounted for the majority of contacts (as high as 72% in detached homes) and a key observation is that many would be avoidable by taking additional care on site and following accepted good practice.

Figure 11 Minimising noise transmission (AD E E1) between new homes. Separating wall and floor joist detailing to minimise sound transmission Photograph courtesy Robust Details Ltd

Page 14: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

References

12 NHBC Foundation Sound progress

References

1 Approved Document E 2003 (amended). Resistance to the passage of sound. Available from the Department for Communities and Local Government Planning Portal: www.planningportal.gov.uk/buildingregulations/approveddocuments.

2 Robust Details Annual Review 2010. Keeping sound where it belongs. Downloadable from: www.robustdetails.com/Support/Downloads.

Page 15: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

NHBC Foundation recent publications

To see NHBC projects currently underway and likely publication dates, please visit www.nhbcfoundation.org and view the Research tab.

Cellulose Based Building Materials – Use, performance and risk

Interest and awareness about the embodied energy associated with the production, use and disposal of construction materials remains topical, resulting in traditional cellulose-based building materials such as thatch, cob, hemp and lime, or straw bales being re-examined as potential low impact building materials, products and systems.

This report provides a brief history of cellulose-based building materials, and reviews the current developments in their use. It looks at the use and performance of such materials, examining the potential benefits and associated risks – informing the debate and resulting in a better understanding about the use of low impact building materials. In addition, the report also provides examples of recent projects built in the UK. NF 55 November 2013

Review of co-heating test methodologies

The co-heating test has been developed to assess the amount of heat that leaks through the thermal envelope of a building – the ground floor, walls, roofs and windows, etc. It is currently the only test available for assessing whole buildings and providing a measure of as-built performance. This report shows results from a programme of work designed to evaluate the reproducibility of the co-heating test. Tests were carried out on a single house by the seven separate test organisations which partnered on this project. Results varied considerably, suggesting that more work was needed to ensure that the test was an accurate predictor of as-build performance. The work considered some effects which may be contributing to the variation in test result and how these might be controlled. NF 54 November 2013

Low- and zero-carbon technologies in new homes

Building on earlier research, this study by Reading University explores how occupants use the low carbon energy technologies incorporated in their homes. The work shows that occupants generally have a poor understanding of these technologies and, through poor or incorrect operation, may not be fully benefiting from them. It examines in particular the key role that sales staff could play in inspiring occupants in the effective use of these technologies. The report provides a detailed insight into the day-to-day marketing and use of homes with LZC technologies and includes an improvement cycle, which can inform marketing strategy. The work has significance in the run up to 2016, helping to address a potentially crucial aspect of underperformance-in-use of low carbon homes. NF 53 August 2013

Cellulose-based building materials

Use, performance and riskThere are many examples of crop-derived materials that have been used in

construction – English Heritage has estimated that there could be as many as

500,000 cob or earth buildings in the UK. Recent work has seen these traditional

cellulose-based building materials being re-examined as potential low impact

building materials, products and systems. For such materials to become more

widely accepted, it is important that they can be properly evaluated and assessed

alongside other products and materials.

This report provides a brief history of cellulose-based building materials, and

reviews the current developments in their use. lt discusses use and performance

issues and examines the potential benefits and risks associated. It also provides

examples of recent projects built in the UK.

NHBC Foundation has been established to facilitate research and development,

technology and knowledge sharing, and the capture of industry best practice.

NHBC Foundation promotes best practice to help builders, developers and the

industry as it responds to the UK’s wider housing needs. NHBC Foundation carries

out practical, high quality research where it is needed most, particularly in areas such

as building standards and processes. It also supports house builders in developing

strong relationships with their customers.

© NHBC Foundation. November 2013

Published by IHS BRE Press on behalf of NHBC Foundation

ISBN 978-1-84806-355-6

55

Cellulose-based building materials

Use, performance and risk

Research review

55

Cellulose.indd 2-3

25/11/2013 14:29

Low- and zero-carbon technologies in new homes

Learning from the experiences of consumers and on-site sales teams

The polarisation between the developer and the consumer forms the starting

point for this research, which focuses on low- and zero-carbon (LZC) technologies

because it is known that these have a significant (perhaps disproportionate) impact

on occupants’ perceptions of their homes. The work gives new insights on the

actual consumer experiences of LZC technologies in their homes. Second, carefully

building upon the consumer findings, the actual knowledge and practices of on-site

sales teams in promoting (or hindering) consumers’ awareness of the benefits of LZC

technologies and their use are explored.

The report provides new real-world insights into the detailed, day-to-day marketing

and use of homes with LZC technologies. Further, these insights inform the

development and demonstration of a continuous improvement marketing approach

for house builders.

NHBC Foundation has been established to facilitate research and development,

technology and knowledge sharing, and the capture of industry best practice.

NHBC Foundation promotes best practice to help builders, developers and the

industry as it responds to the UK’s wider housing needs. NHBC Foundation carries

out practical, high quality research where it is needed most, particularly in areas such

as building standards and processes. It also supports house builders in developing

strong relationships with their customers.

© NHBC Foundation. November 2013

Published by IHS BRE Press on behalf of NHBC Foundation

ISBN 978-1-84806-349-5

53

Low- and zero-carbon technologies in new homes

Learning from the experiences of

consumers and on-site sales teams

Primary research

53

Review of co-heating test methodologies

As our understanding of the issues involved in delivering energy-efficient housing

has developed, there has been growing concern about the performance gap

between design expectations and in-use outcomes. The co-heating test, developed

in its present form by Leeds Metropolitan University, provides a means by which the

as-built performance can be measured. In practice, the reliability and practicality

of co-heating tests for large scale application across the construction industry has

been questioned due to the long test duration and uncertainty in the heat loss

coefficient. This report describes a series of co-heating tests undertaken by test teams from BRE

and six project partners (commercial and academic) in one of BRE’s test houses, with

a second identical test house used as a control.

The project assessed the approaches taken by investigators undertaking the

co-heating test, with particular regard to test protocols, data analysis and treatment

of uncertainties.

NHBC Foundation has been established to facilitate research and development,

technology and knowledge sharing, and the capture of industry best practice.

NHBC Foundation promotes best practice to help builders, developers and the

industry as it responds to the UK’s wider housing needs. NHBC Foundation carries

out practical, high quality research where it is needed most, particularly in areas such

as building standards and processes. It also supports house builders in developing

strong relationships with their customers.

© NHBC Foundation. November 2013

Published by IHS BRE Press on behalf of NHBC Foundation

ISBN 978-1-84806-351-8

54

Review of co-heating test

methodologies

Primary research

54

PO70 Co-HeatingSS.indd 2-3

04/11/2013 17:59

Page 16: Sound progress · problem, AD E 2003 introduced new performance targets for airborne and impact sound resistance for separating walls and floors. It also set out a requirement for

Sound progress A review of homeowner feedback on noise in new homes

In the 1990s noise transmission was a major cause of dissatisfaction for occupiers of attached homes. To address this problem, sound insulation standards were tightened in the 2003 edition of Approved Document E (AD E) and in 2004 the Robust Details scheme became available as a compliance route for designers and house builders. To understand the impact of these measures on the ground, this NHBC Foundation report examines feedback on noise from occupants of new homes built since 2004. For attached homes the work identifies an encouraging downward trend in the number of concerns on transmitted sound, suggesting that AD E and supporting guidance has progressively improved performance for the benefit of house buyers.

The NHBC Foundation, established in 2006, provides high quality research and practical guidance to support the house-building industry as it addresses the challenges of delivering 21st century new homes. To date the NHBC Foundation has published over 50 reports on a wide variety of topics, including the sustainability agenda, homeowner issues and risk management. Visit www.nhbcfoundation.org to find out more about the NHBC Foundation research programme.

© NHBC Foundation. April 2014Published by IHS BRE Press on behalf of the NHBC FoundationISBN 978-1-84806-373-0

56