Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Solutions Partner CatalogKeysight Technologies & TOYO Corporation
EMC Measurements
Emission Measurement Software ……………………………………………………………… 4
Immunity Test Software ………………………………………………………………………… 5
EMI Measurement System ……………………………………………………………………… 6
TEM-wave Large-bandwidth Transmission Line System G-CELL ……………………… 8
GTEM CELL ……………………………………………………………………………………… 10
Common Mode Noise Measurement System TS1000 ………………………………… 12
Oscilloscope for Immunity Pulse Waveform Observation ……………………………… 13
Radiated/Conducted Immunity Test System …………………………………………… 14
For Shielding Material Permeation Loss Measurement ………………………………… 16
Table of Contents
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements02
About TOYO CorporationTOYO Corporation, as an expert in measurement technology, has been
proactively breathing fresh life into the sunrise industry such as energy and
environment, along with its mainstream business including electromagnetic
interference measurement and communication measurement. Striving for a
name trusted in the market innovation technology, not only a measurement
technology provider, we, at TOYO, redouble our efforts to expand the
laboratories, impart technical knowledge, improve the training facilities and
enrich technical training for employees.
In recent years, TOYO has been delivering carefully needs-matched solutions
to each customer through self-developed system products and will be
committed to promptly catering to the demand for technological innovation
with a reinforced development group.
Technology Interface Center
“Measurement”echnology constitutesthe mainstay of all businesses -this is what TOYO believes.
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements03
EMC Measurements
Emission Measurement SoftwareOverviewWith electronic devices going digital and mobile through high-density implementation, it is getting more difficult to isolate noise sources, and more cost- and time-consuming to implement appropriate EMI remedies against them.TOYO EP7 software, which is designed for EMI evaluation measurements, collects and saves a greater-than-ever amount of data on the complicated noises emitted by such digital devices, thereby detecting noises that could not be captured before through automated measurements with enhanced speed and reliability. Furthermore, the EP7 has reinforced functionality for the post-measurement evaluation and analysis of DUT through multi-angle visualization of an enormous amount of measurement data among other means.TOYO EP9 software, which is meant for automobile EMI measurements, has been developed to be compliant with diversifying international and automobile manufacturers’ own standards. The EP9 adopts a matrix system that allows users to narrow down measurement conditions simply by selecting a standard and a transducer.
Software- EP5/RE : Radiated emission measurement software- EP9/CE : Conducted emission measurement software- EP5/REP : RF power emission measurement software - EP5/NSA : Site attenuation measurement software- EP7/RE : Radiated emission measurement software- EP7/CE : Conducted emission measurement software- EP5/RSE : Radiated Spurious emission measurement software - EP9/VE : Radiated emisson measurement software for vehicle
Applicable standards- Consumer product standards : CISPR, EN, ETS, FCC, VCCI- Wireless Application standards : TS51.010-1, TS34.121 (3GPP),
Cellular phones (GSM, WCDMA), EN300 328, EN301 893 (ETSI)
- Automotive standards : UN/ECE R10, CISPR12, CISPR25, SAE, JASO
Basic measurement function- Spectrum data acquisition- Maximum radiation position measurement (azimuth/height pattern, clamp position)- Quasi-peak(QP)/Average(AV) measurement according to CISPR Pub. 16- Measurement result display/output/edit/save
Feature- Sophisticated user interface- Flexibility in window layout setting- Measurement procedure reduces measurement time- Instrument and system self-diagnostic function- Spectrum overwrite function efficient for corrective action- Measurement result data aditable by MS-Word and Excel- Capable of saving standard limits, factors, measurement system gain/loss, and
measurement conditions to files, enabling them to be set, edited, and created easily.- Capable of changing limits freely after measurement- Template feature allowing icons to be assigned to individual tests- Support for many types of hardware products of various manufactures- Assorted password function for distinguishing between measurement operator
and administrator
EP7/RE : radiated emission measurement software Display of 3D Time Domain
EP7/RE : radiated emission measurement software Display of 3D radiation pattern
EP7/RE : Radiated emission measurement software Display of measurement
EP9/VE : Radiated emission measurement software for vehicle Display of measurement
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements04
Software- M5/RS : Radiated immunity test software- IM5/CS : Conducted immunity test software- IM5/A : Audio immunity test software- IM5/V : TV/Video immunity test software- VI5/RS : Vehicle radiated immunity test software
Applicable standards- Consumer product standards : IEC61000-4-3,-6, CISPR24, EN- Automotive standards : UN/ECE R10, SAE, JASO, GM/Ford standards (radar pulse)
Standards in other auto manufacturers- MIL standards : Standards for medical device
Basic measurement function- Electric field uniformity measurement- System linearity testing- Electric field reference measurement/ Electric field check- Immunity test- Display of measured results- Report generation
Feature- Sophisticated user interface- Measurement procedure that dramatically reduces measurement time- Capable of exporting measurement data in CSV format- Capable of saving standard values, factors, and measurement conditions to
files, enabling them to be set, edited, and created easily- Support a wide range of hardware of various manufactures- Various password function are provided for a range of password levels, from
the staff in charge of making measurement and to the system administrator
Immunity Test SoftwareOverviewTOYO IM5 series software, which performs automated immunity testing, has been developed to evaluate the immunity of electronic devices against electromagnetic interference. The IM5’s capability to automatically control the instruments required for immunity testing (e.g. a signal generator, power amplifier system, electric-field strength meter, power meter, and antenna mast) allows any users to conduct EMI measurements in an efficient and secure manner, as well as to output measurement data to a printer and to save such data on a hard disk drive. With an error detection option installed, the IM5 monitors the DUT being subjected to an immunity test and, if any limit setting is exceeded, detects it as an error. TOYO VI5 series software, which also is for automated immunity testing, has been developed specifically to test automobiles for their immunity against electromagnetic interference. As is the case with all other TOYO EMC/EMI software applications, the VI5 is constantly updated and upgraded to better serve customer needs, an example of which is the implementation of an error detection function utilizing CAN/LIN bus monitor and image recognition.
IM5/RS : Radiated immunity test software Immunity measurement result window
VI5/RS : Vehicle immunity test software Display of CAN measurement error detection
VI5/RS : Vehicle immunity test software Display of image-recognition error detection
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements05
Shielded room or radio anechoic chamber
Spectrum analyzer/ EMI test receiver Biconical antenna
[30 MHz-300 MHz]
Antenna mast
LISN
Absorbing clamp
Clamp travel gear
(Auxiliary clamp)
ISN
Radiated noise measurement setup
Terminal noise measurement setup
Noise power measurements setup
Preamplifier[1-8 GHz]
Preamplifier[max. 1 GHz]
Log periodic antenna[300 MHz-1 GHz]
(Biconilog antenna)[30 MHz-1 GHz]
Horn antenna[1 GHz-6 GHz]
HAP antenna[6-18 or 40 GHz]
EUT
EUT table
Turntable
Optical fiber cable
System controller
Clamp controller
Mast/ Table controller
Auto measurement software
RF cableGPIB cableOptical fiber cableUSB cable
RF selector
Measurement room Radio anechoic chamber
EMI Measurement System - CISPR-approved system -
EMI measurement system best suited to customer needs
OverviewThe electronics industry moves toward the digitalization and mobilization of equipment with higher density packaging, making the determination of noise source and EMC control more challenging.There are increasing demands to expand upper limited frequency, adhere to frequently-revised standards, and acquire and store data on more complex noise to the greatest extent possible.TOYO’s 30 years of technical expertise has trickled down to its automatic systems based on impressive records of supplying hundreds of systems to various businesses from public test laboratories through commercial EMC test houses.TOYO’s time-proven systems offer the user a wide choice of options, from full compliance fully-automatic measurement to preliminary simplified measurement.
Basic measurement functions- Capable of acquiring spectrum and QP detector
measurement with a single click.- Endowed with functions effective for manual
measurements.- Capable of exporting data.
SoftwareEP7 Series (3D display with a detailed noise analysis function)- EP7/RE type : Radiated noise weighting and measurement
software- EP7/CE type : Terminal noise weighting and measurement
softwareEP5/EP9 Series (With a standard noise analysis function)- EP5/RE type : Radiated noise measurement software- EP5/RFP type : Noise power measurement software- EP5/RSE type : Radiated spurious emission measurement
software- EP9/CE type : Terminal noise measurement software
Applicable standards- Consumer product standards :
CISPR, EN, FCC, VCCI
- Wireless Application standards : TS51.010-1, TS34.121 (3GPP) Cellular phones (GSM, WCDMA) EN300 328, EN301 893 (ETSI)
- Automotive standards : CISPR12, CISPR25, UN/ECE R10, SAE, JASO
CISPR-compliant EMI test receiver with an integrated preselector
N9038A MXE EMI receiverFrequency : 3 Hz – 3.6/8.4/26.5/44 GHz
EMC Measurements
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements06
Shielded room or radio anechoic chamber
Spectrum analyzer/ EMI test receiver Biconical antenna
[30 MHz-300 MHz]
Antenna mast
LISN
Absorbing clamp
Clamp travel gear
(Auxiliary clamp)
ISN
Radiated noise measurement setup
Terminal noise measurement setup
Noise power measurements setup
Preamplifier[1-8 GHz]
Preamplifier[max. 1 GHz]
Log periodic antenna[300 MHz-1 GHz]
(Biconilog antenna)[30 MHz-1 GHz]
Horn antenna[1 GHz-6 GHz]
HAP antenna[6-18 or 40 GHz]
EUT
EUT table
Turntable
Optical fiber cable
System controller
Clamp controller
Mast/ Table controller
Auto measurement software
RF cableGPIB cableOptical fiber cableUSB cable
RF selector
Measurement room Radio anechoic chamber
EMI Measurement System
SpecificationModel
M9403A PXIe optical transmitter: 300 kHz to 26.5 GHz or 50 GHz
M9404A PXIe optical receiver: 300 kHz to 26.5 GHz or 50 GHz
M9405A PXIe amplifier: 300 kHz to 26.5 Gz or 50 GHz
M9406A PXIe optical to USB 2.0
M9407A PXIe optical to 4 port USB 2.0 hub
M9408A PXIe remote RF reflectometer
Pre-compliance spectrum analyzer X Series
N9030B PXA signal analyzerFrequency : 3 Hz – Max. 50 GHz
FCC standard (1-40 GHz)-compatible model
N9020B MXA signal analyzerFrequency : 10 Hz – Max. 26.5 GHz
CISPR standard (Min. 1 GHz)-compatible model
N9010B EXA signal analyzerFrequency : 10 Hz – Max. 44 GHz
M940X Series PXIe Optical Extenders
Keysight Technologies M940X Series PXIe Optical ExtendersThe M940X series PXIe optical extenders convert RF and microwave signals into optical signals and transmit them more than 1000 meters. Since optical fibers are superior to coaxial cables in transmission loss and noise resistance, the M940X optical extenders allow you to build a high-sensitivity radiated emission measurement system.
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements07
Overview TOYO’s G-CELL is a cubic cell upgraded from TEM CELL, enabling easy radiated EMI measurement and immunity test of EUTs in the transmission line installed on the floor. User-friendly G-CELL is favorable for immunity control and preliminary measurements before authentication tests in a radio anechoic room andopen site.
Feature- Capable of easy EMI measurement with the
spectrumanalyzer. - Enables radiated immunity test assuring consistency.- Large opening design allowing easy EUT installation.- Customizable power/signal line filters.
Applications- Radiant emission measurement- Radiant immunity test
Specifications- Frequency range : 10k-1GHz(2GHz)- Max. input power : 150W(Type N connector)- Dimensions : 70x70x70cm (protrusion excluded)- Applicable EUT size : 40x40x40cm- Shielding performance : Min. 70dB
Software- EP5/ME : Simplified EMI measurement software- IM5/RS : Radiated immunity test software
G-CELL
TEM-wave Large-bandwidth Transmission Line System G-CELLDesigned for EMI measurement and analysis and assessment of radiated immunity test
EMC Measurements
Frequency[MHz]
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements08
Electric field sensor
N5181A MXG signal generator(recommended)
RF power amplifier G-CELL
G-CELL 310N preamplifier N9010B EXA signal analyzer(recommended)
Standard componentsModel Equipment
G-CELL TEM-wave large-bandwidth transmission line system
EP5/ME Simplified EMI measurement software
N9010B EXA Signal analyzer (10 Hz – 3 GHz)
310N Preamplifier
50 Ω termination
Computer, a set of cables (RF, GPIB)
Standard componentsModel Equipment
G-CELL TEM-wave large-bandwidth transmission line system
IM5/RS Radiated immunity test software
N5171B Signal generator (9 kHz – 3 GHz)
power amplifier
Electric field sensor
50 Ω termination
Computer, a set of cables (RF, GPIB)
Connection diagram for radiated emission measurement
Connection diagram for radiated immunity test
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements09
GTEM CELL
OverviewOur GTEM CELL is apt for EMC applications, antenna/ magnetic field probe and cellular phone tests in tandem with an upgrade frequency band from TEM (Transverse Electro Magnetic) CELL. The extended frequency band also lends itself to part sorting and measurements.
Features- Stable shielded environment for EMI measurement
and immunity test- Compliant with the IEC/EN61000-4-20 and FCC ANSI
C63.4 standards.- Designed for broad spectrum (DC-20 GHz).- Offers a rich lode of GTEM CELL models (septum
height ranging from 250 mm to 2000 mm)- Outstanding VSWR over the entire frequency band- Customizable power/signal line filters
Software- EP5/ME type: Simplified EMI measurement software- IM5/RS type: Radiated immunity test software
Applications- Radiant emission measurement- Radiant immunity test
Specifications
GTEM250 GTEM500 GTEM750 GTEM1000
Septum height (mm) 250 500 750 1000
Dimensions (m) 1.25 x 0.65 x 0.45 2.95 x 1.48 x 1.61 3.95 x 2.02 x 1.95 4.95 x 2.54 x 2.30
Dimensions of test product (m) 0.15 x 0.15 x 0.08 0.30 x 0.30 x 0.15 0.45 x 0.45 x 0.22 0.60 x 0.60 x 0.30
Max. input power (w) 50 W 100 W 200 W 1000 W
GTEM1250 GTEM1500 GTEM1750 GTEM2000
Septum height (mm) 1250 1500 1750 2000
Dimensions (m) 5.95 x 3.06 x 2.52 6.95 x 3.58 x 2.55 7.95 x 4.10 x 2.90 8.95 x 4.62 x 3.24
Dimensions of test product (m) 0.70 x 0.70 x 0.38 0.85 x 0.85 x 0.45 1.00 x 1.00 x 0.50 1.15 x 1.15 x 0.60
Max. input power (w) 1000 W 1000 W 1000 W 1000 W
GTEM CELLExcellent for analysis and assessment of EMI and immunity control
EMC Measurements
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements10
GTEM CELL
Electric field sensor
N5171B EXG signal generator(recommended)
RF power amplifier
GTEM CELL
310N preamplifier N9010B EXA signal analyzer(recommended)
Connection diagram for radiated emission measurement
Standard componentsModel Equipment
GTEM CELL
EP5/ME Simplified EMI measurement software
N9010B EXA Signal analyzer (10 Hz – 26.5 GHz)
310N Preamplifier
Computer, a set of cables (RF, GPIB)
Connection diagram for radiated immunity test
Standard componentsModel Equipment
GTEM CELL
IM5/RS Radiated immunity test software
N5171B Signal generator (9 kHz – 6 GHz)
Power amplifier
Electric field sensor
Computer, a set of cables (RF, GPIB)
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements11
Inside of FC-1000
EP6/FC Faraday gauge measurement software
FC-1000 system 310N preamplifier
RF RF GPIB
N9010B EXA signal analyzer PC
Easy noise suppression achieved in common mode noise measurement
OverviewTOYO’s savvy has made it possible to attain the accuracy of common mode noise measurement closest to that of spurious noise measurement in a radio anechoic room, using the Workbench Faraday Cage (IEC61967-5), an EMC performance assessment method of a semiconductor. Sporting reproducibility superior to conventional measurements in a radio anechoic room, our TS1000 is effective in EMI control during the product development stage.
Features- Unsusceptible to radiated noise, delivering high data
reproducibility.- Capable of measurements in a low-noise floor level.- Speedy, fuss-free measurements as compared with noise
measurements in a radio anechoic room- Allows common mode noise measurements in any office
environments.
Applications- Radiant emission measurement
FC-1000 Main Specifications- Mmeasuring frequency range: 30-1000MHz- Max. outer dimensions: 950mm (L) x 780mm (w) x 220mm (H)- Weight: 29.2kg- I/O voltage range : -48~48VDC- I/O current range : 0-2ADC- Number of power input terminals : 6 systems- Number of signal I/O terminals : 3 systems*No AC input and output enabled
Standard componentsModel Equipment
FC-1000 Faraday cage
EP6/FC Faraday cage measurement software
N9010B EXA Signal analyzer (9 k-3.6 GHz)
310N Preamplifier
Computer, a set of cables (RF, GPIB)
Connection diagram
Common Mode Noise MeasurementSystem TS1000
EMC Measurements
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements12
Oscilloscope for Immunity PulseWaveform Observation
TESEQ Model NSG437Discharge voltage 200 V-30 kV (IEC61000-4-2-compatible)
Software-controlled instantaneous waveform check
OverviewThe IEC-defined immunity standards provides for a pulse shape check in calibration and daily inspection. ESD waveforms which have the quick leading edge of sporadic pulse especially require the utilization of a wide band oscilloscope.
Features- Designed to meet a sample speed and frequency
band- Software-controlled automatic waveform
measurement and report generation
Applications- Waveform calibration and daily inspection
Standard componentsModel Equipment
Infiniium S SeriesDSO/MSO9000A Series
Oscilloscope
MD103 ESD waveform observation target (IEC61000-4-2)
CAS3025 EFT/ burst observation attenuator (IEC61000-4-4)
MD200 Surge waveform observation probe (IEC61000-4-5)
MD300 Surge waveform observation probe (IEC61000-4-5)
Recommended oscilloscope ESD oscilloscope waveform
DSO/MSO9000A Seriesoscilloscope
Infiniium S Seriesoscilloscope
EMC Measurements
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements13
Shielded room or radio anechoic chamber
Antenna mast
150 W/50 WConversion
adapter
Radiated immunity test setup
Conducted immunity test setup
Log periodic antenna [80MHz-1GHz]
(Horn antenna)[1GHz-2.5GHz]
(Horn antenna)[2.5GHz-6GHz]
RF amplifier[150kHz-230MHz]
Stacked log periodic antenna[1GHz-6GHz]
EUT
EUT
Termination
To monitoring spectrum analyzer
EUT table
Attenuator
To power supply CDN
Electric field sensor
Sensor mast
Optical fiber cableRF cableGPIB cableOptical fiber cableUSB cable
RF selector
(Selector controller)
(Signal generator)
Spectrum analyzer
System controller
Directional coupler
Radiated immunity automatic test softwareConducted immunity automatic test software
Optical GPIB converter
Optical USB converter
Directional coupler
Measuring instrument rackSignal generator
Power sensorF1
F1R1
F2R2
F3R3
R1R2R23
F2F3
Power meter
Power meter
Measurementroom Radio anechoic chamber
Recommended signal generator
N5171B ・N5173BMXG signal generator
Immunity test system best suited to customer needs
OverviewTOYO offers a valuable test system to assess electromagnetic interference in electronic equipment. Installed with Radiated Immunity Test Software IM5, our immunity test system automatically controls the signal generator, power amplifier system, electric field sensor, power meter and antenna mast. It also supports outputting and saving of test results.
Basic measurement functions- Electric field uniformity measurement- System linearity testing- Electric field reference measurement/ Electric field
check- Immunity test- Display of measured results- Report generation
SoftwareM5/RS type: Radiated immunity test softwareIM5/CS type: Conducted immunity test softwareVI5/RS type: Vehicle radiated immunity test software
Applicable standardsConsumer product standards- IEC61000-4-3,6- CISPR24- EN
Automotive standards- UN/ECE R10- ISO11452-1/2- SAE- JASO- GM/Ford standards (radar pulse)- Standards in other auto manufacturers
MIL standards
Standards for medical devices
Radiated/Conducted Immunity Test System – Compliant with international and company standards –
EMC Measurements
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements14
Shielded room or radio anechoic chamber
Antenna mast
150 W/50 WConversion
adapter
Radiated immunity test setup
Conducted immunity test setup
Log periodic antenna [80MHz-1GHz]
(Horn antenna)[1GHz-2.5GHz]
(Horn antenna)[2.5GHz-6GHz]
RF amplifier[150kHz-230MHz]
Stacked log periodic antenna[1GHz-6GHz]
EUT
EUT
Termination
To monitoring spectrum analyzer
EUT table
Attenuator
To power supply CDN
Electric field sensor
Sensor mast
Optical fiber cableRF cableGPIB cableOptical fiber cableUSB cable
RF selector
(Selector controller)
(Signal generator)
Spectrum analyzer
System controller
Directional coupler
Radiated immunity automatic test softwareConducted immunity automatic test software
Optical GPIB converter
Optical USB converter
Directional coupler
Measuring instrument rackSignal generator
Power sensorF1
F1R1
F2R2
F3R3
R1R2R23
F2F3
Power meter
Power meter
Measurementroom Radio anechoic chamber
Immunity Test System
Recommended power meters
P Series Power MeterN1912A
EPM Series Power MeterN1914A
TA0122-10K
RF power amplifier TA series(10kW/5kW/2.5kW)RF power amplifier TA series is a solid state (semiconductor device)-laden high power amplifier, delivering output linearity and stability as fundamental performance. TA series is designed for high reliability and quality.
Features‒ 10 kW of high power output
(7 kW@1 dB comp.)‒ Easy maintainability through RF
unit replacement‒ Equipped with the internal data
storage function which is capable of easy cause analysis of a malfunction.
SpecificationsModel Frequency Output
TA0122-10K 10 k-225 MHz 10 kW
TA0122-5K 10 k-225 MHz 5 kW
TA0122-2.5K 10 k-225 MHz 2.5 kW
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements15
OutlineJSE-KEC and JSE-KEC6G systems are developed by KEC Electronic Industry Development Center to measure the permeation loss of sheet and film shielding materials in an easy way.
Specifications
JSE-KEC JSE-KEC6G
Compliant standard/method
KEC Method ASTM D 4935-10 (2010 edition)
Frequency range 100 kHz - 1 GHz 1 GHz - 6 GHz
Dynamic range 80 dB (nominal, depends on input level and receiver's measurement limitations)
Sample size approx. 110X100 mm - 6 mm thick or less approx. 30~50 mm square - 1 mm thick or less
Outer dimensions and weight
W350×D350×H500(excluding protrusions)approx. 25 kg
W300×D350×H350(excluding protrusions)approx. 20 kg
Accessories Blind plate x 1, Thickness calibration plate x 3 Blind plate x 1
Outstanding features- No need for complicated material processing- All it takes is to insert a sample into a jig- Wide frequency coverage
100kHz~1GHz, 1GHz~6GHz- Dedicated software enables automatic shielding
effect measurement- Offered as a system with a network analyzer and
measurement software
Shielding effect measurement software- SEMS
RF Cable
RF Cable
Network analyzer(Keysight Technologies)
LAN Contorl
SEMSShielding effect measuremetn software
JSE-KEC6G
System configuration example with JSE-KEC6G [S21 permeation loss measurement]
S21 Shielding effect measurement
These systems enable you to evaluate shielding materials in a relativemanner in a short time and with no sweat!
EMC Measurements
For Shielding Material Permeation Loss MeasurementJSE-KEC System (for shielding effect measurement by KEC method)
JSE-KEC6G System (for GHz-band shielding effect measurement)
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements16
SEMS Measurement Software
Allows you to select a jig and initialize the network analyzer.
Displays measurement results as 《Shielding effect[dB]》 on an Excel spreadsheet for review at a glance
Superimposes measurement results on a graph and outputs lists for individual measurements on separate sheets.
Standard configurationModel Description
JSE-KEC Shielding effect measurement systemJSE-KEC6G
EP9/SH Measurement software
3 dB attenuator, Coaxial cable
E5071C Network analyzer
①Select a system Set meas. condition
②Execute THRU cal.
③Measure shielding effect
Re-measure the same EUT
Normal sequence
Optional sequence (skip or repeat some steps)
You can return to "① Set meas. condition" from anywhere in the sequence.
Connect the EUT Remove the EUT
Re-do calibration
Change the system
Measureanother
EUT
Skipcalibration
Basic operation sequence
JSE-KEC KEC method shielding effect measurement system
(for electric filed)* JSE-KEC comes standards with a jig for the
electromagnetic field.
Measurement software setting screenfor selecting a jig and initializing the network analyzer
Excel data output example Measurement results are output as 《shielding effect [dB]》.
*An English version of SEMS software is now under development. Measurement graph example
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
Copper mesh(1mm)
Copper foil(75µm)
Shie
ldin
g ef
fect
[dB]
Frequency [GHz]1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements17
M E M O
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements18
M E M O
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements19
© Keysight Technologies, 2017Published in Japan, February 21, 20175990-9819ENJP0000-08cSwww.keysight.co.jp
This information is subject to change without notice.
TOYO Corporation1-6, Yaesu 1-chome, Chuo-ku, Tokyo 103-8284, JapanTEL +81-(0)3-3279-0771FAX +81-(0)3-5205-2030Contact : https://www.toyo.co.jp/contacts/URL : http://www.toyo.co.jp
TOYOTech LLC42840 Christy Street, Ste.209Fremont, CA 94538TEL +1 510.438.9548URL : http://www.toyotechus.com
TOYO Corporation ChinaRoom 310 Enterprise Square, No.228 Mei Yuan Road, Jing’an District, Shanghai 200070, P.R. ChinaTEL +86 021-6380-9633URL : http://www.toyochina.com.cn
Keysight & Solutions PartnersExtending our solutions to meet your needs
EvolvingOur unique combination of hardware, software, support, and people can helpyou reach your next breakthrough. We are unlocking the future of technology.
From Hewlett-Packard to Agilent to Keysight
* Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG, Inc., U.S.A. and licensed to Keysight Technologies, Inc.
* WiMAX, Mobile WiMAX, WiMAX Forum, the WiMAX Forum logo, WiMAX Forum Certified and the WiMAX Forum Certified logo are US trademarks of the WiMAX Forum.
* cdma2000 is a US registered certification mark of the Telecommunications Industry Association.
For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at:www.keysight.com/find/contactus
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444
Asia Pacific
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 11 2626
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122
Belgium 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
Luxembourg +32 800 58580
Netherlands 0800 0233200
Russia 8800 5009286
Spain 800 000154
Sweden 0200 882255
Switzerland 0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus(BP-06-08-16)
| Keysight | Solutions Partner Catalog TOYO Corporation EMC Measurements20