2
SOLUTION SHOWCASE Wearable Injection Pumps Vectra® MT® LCP offers design and production efficiencies when used for the internal chassis Hostaform® MT® SlideX® POM and Celanex® MT® PBT used in internal components offer exceptional low friction and low wear properties improving patients device experience. CELANESE MATERIAL OFFERING Vectra® MT® LCP Portfolio for internal chassis Excellent mechanical performance – high stiffness, tight tolerances, dimensional stability, and thinner wall capability to free internal space for integrated electronics and internal components Managing processing costs – scalability through higher flow to fill higher number of cavity molds and reduce production cycle times Hostaform® MT® SlideX® POM & Celanex® MT® PBT Portfolio for gears, bearings and sliding parts Excellent tribological and mechanical performance: enables precision mechanical components with low friction & wear, no noise, high strength/modulus, fatigue and creep Industry-leading experience in part design and development for injection devices; extensive tribological technical expertise on material pairings and interactions with in-house testing capabilities Medical Technology Service Package: risk reduction and increased stability for customers; support throughout the product life cycle, including regulatory and long-term supply assurance CELANESE DIFFERENTIATING CAPABILITIES Overall growth in biologics from the Pharmaceutical industry is accelerating medical device innovation to deliver higher volume treatments at home. Performance reliability and user comfort are some of the critical needs for which Celanese offers Designers and OEMs a variety of solutions. MT® Medical Technology PRODUCT PORTFOLIO FOR WEARABLE INJECTION DEVICES

SOLUTION SHOWCASE...warpage – ideal for highly complex designs and for optimizing material use Broad portfolio of Vectra® MT® LCP includes glass-filled, mineral-filled, higher-flow,

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SOLUTION SHOWCASE...warpage – ideal for highly complex designs and for optimizing material use Broad portfolio of Vectra® MT® LCP includes glass-filled, mineral-filled, higher-flow,

SOLUTION SHOWCASEWearable Injection Pumps

Vectra® MT® LCP offers design and production efficiencies when used for the internal chassis

Hostaform® MT® SlideX® POM and Celanex® MT® PBT used in internal components offer exceptional low friction and low wear properties improving patients device experience.

CELANESE MATERIAL OFFERING

Vectra® MT® LCP Portfolio for internal chassis

Excellent mechanical performance – high stiffness, tight tolerances, dimensional stability, and thinner wall capability to free internal space for integrated electronics and internal components

Managing processing costs – scalability through higher flow to fill higher number of cavity molds and reduce production cycle times

Hostaform® MT® SlideX® POM & Celanex® MT® PBTPortfolio for gears, bearings and sliding parts Excellent tribological and mechanical performance:

enables precision mechanical components with low friction & wear, no noise, high strength/modulus, fatigue and creep

Industry-leading experience in part design and development for injection devices; extensive tribological technical expertise on material pairings and interactions with in-house testing capabilities

Medical Technology Service Package: risk reduction and increased stability for customers; support throughout the product life cycle, including regulatory and long-term supply assurance

CELANESE DIFFERENTIATING CAPABILITIES

Overall growth in biologics from the Pharmaceutical industry is accelerating medical device innovation to deliver higher volume treatments at home. Performance reliability and user comfort are some of the critical needs for which Celanese offers Designers and OEMs a variety of solutions.

MT® Medical Technology

PRODUCT PORTFOLIO FOR WEARABLE INJECTION DEVICES

Page 2: SOLUTION SHOWCASE...warpage – ideal for highly complex designs and for optimizing material use Broad portfolio of Vectra® MT® LCP includes glass-filled, mineral-filled, higher-flow,

Lighter-weight, increased comfort and greater design flexibility

Vectra® MT® LCP MT1305, a higher-flow grade, modified to provide extraordinary easy flow and low warpage – ideal for highly complex designs and for optimizing material use

Broad portfolio of Vectra® MT® LCP includes glass-filled, mineral-filled, higher-flow, tribologically modified, and appearance grades – suitable for a variety of uses in medical device applications

Certified biocompatibility (USP Class VI / ISO 10993)*

Food contact compliance (US FDA and EU)

Animal- and latex-free formulations

US FDA Drug & Device Master file listing

Production according to GMP principles

Additional analytical & individual batch testing

Notification of Change procedure

Improved technical properties, processability and patient comfort

MT® SLIDEX® grades excellent performing medical grades

with tribological modifiers for low wear & friction, and no noise

no running-in effects, suitable for dry run applications

Appearance Specialties include laser-markable and pre-colored grades

VECTRA® MT® LCP

This publication was printed based on Celanese’s present state of knowledge, and Celanese undertakes no obligation to update it. Because conditions of product use are outside Celanese’s control, Celanese makes no warranties, express or implied, and assumes no liability in connection with any use of this information. Nothing herein is intended as a license to operate under or a recommendation to infringe any patents.

Celanese®, registered C-ball design and all other trademarks identified herein with ®, TM, SM, unless otherwise noted, are trademarks of Celanese or its affiliates.

Hostaform® is a registered trademark of Hoechst GmbH, used by Celanese Corporation under license. Fortron® is a registered trademark of Fortron Industries LLC, used by Celanese Corporation under license.

Copyright © 2019 Celanese or its affiliates. All rights reserved. Brochure Publication Number: LCP-001-LargeVolumeWearablePumps-SS-EN-0119

PRODUCT FEATURES

CELANESE MEDICAL TECHNOLOGY SERVICE PACKAGE INCLUDES

HOSTAFORM® MT® SLIDEX ® POM CELANEX MT® PBT

MT®: Medical Technology

*Vectra LDS grades do not have certified biocompatibility

Americas8040 Dixie Highway, Florence, KY 41042 USAProduct Information Servicet: +1-800-833-4882 t: +1-859-372-3244

EuropeAm Unisys-Park 1, 65843 Sulzbach, GermanyProduct Information Servicet: +(00)-800-86427-531 t: +49-(0)-69-45009-1011

Contact Information: healthcare.celanese.com [email protected]

Customer Servicet: +1-800-526-4960 t: +1-859-372-3214

Asia4560 Jinke Road, Zhang Jiang Hi Tech ParkShanghai 201203 PRCCustomer Servicet: +86-21-3861-9266 f: +86-21-3861-9599