Upload
sudharshan-srinath
View
109
Download
4
Tags:
Embed Size (px)
DESCRIPTION
Dimensioning
Citation preview
© 2011. Siemens Product Lifecycle Management Software Inc. All rights reservedSiemens PLM Software
DRAFTSolid Edge ST4 Update Training
Draft
Presented by: Steve Webb
Page 2© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
TopicsParts List
Table TitlesColumn HeadersHeaders MergingHeader RotateCell Aspect RatioCell FormattingOverriding Disabled CellsInserting User Defined RowsConvert Deleted Parts/Assemblies to User Defined RowsDisplay Control through ConfigurationMerge Vertical Cells with Same Value
Page 3© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
TopicsDrawing Views
CaptionsDeleteDisplay while draggingFixed PositionBreak Lines
Section ViewsRibs
Sheet ScaleDimensionsDrawing View StyleAnnotations
SymbolsAuto balloon – Fastener SystemsCallout – Aspect RatioFeature Control FrameText Box
Page 4© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
TopicsReattach CenterlineReattach Center marks
Page 5© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Table TitlesWith ST4, users have the ability to control Fonts, Alignment and Auto-adjust aspect ratio to fit title width for Parts List Title
Alignment LeftCenterRightIndent
Adjust text to title width - when the length of the title exceeds the cell width, the aspect ratio (ratio of the width of the image to its height)of the title text automatically adjusts to fit the cell width
Page 6© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Table TitlesOptionsFont – adjusts the font of the title textFont style – adjusts the font style of the title textFont size – adjusts the size of the textUnderline – underline title text
Page 7© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Column HeadersColumn Header implemented for all tables (Table, Parts List, FOP Table and Bend Table)
Show headers – When checked, all header cells will display
Position – All header cells move togetherHeaderFooterBothNeither
Fixed header row height – the column header cells are a fixed height and are not derived from the text height
Page 8© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Column Headers
Multiple Column Header Rows
Show two rows – the header of the specified column will have two independent cells for the header
Row number - which row in the column header the properties are being applied
Format Table Cells - displays the Format Table Cells dialog allowing the user to control the alignment and orientation
Page 9© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Headers MergingFixed data row height - column header cells are fixed height and not derived from the text height
Merge with next header - merges vertical cells with same value. Column header cell is to be merged with the header cell adjacent to the right
Page 10© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Header Rotate
Header OrientationHorizontal – default horizontal display of the text
Rotated –rotates the header text 90 degrees counterclockwiseVertical – displays each character in the header vertically one after another on separate text lines
When the column header is rotated, the rotation is 90 degrees counterclockwise
Justification still applies to the text in the cell
Page 11© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Table StylesControlling Table styles
The line style between the two cells is controlled by the ‘Header Separator’ in the table style
Header-Data SeparatorHeader Separator
Page 12© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Cell Aspect Ratio
Cells in tables have been enhanced so that the text within each cell adjusts the aspect ratio of the text to fit within the column width
Change the HeaderSelect column, Format Cells, Adjust text to column width
Change DataSelect column, FormatCells, Adjust text to column text
Page 13© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Data
User can now control Font for any cellBold fontsItalic fontsUnderline fontJustification
Page 14© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Overriding Disabled Cells
Disabled cells may be enabled for user override of the derived cell text
Allow Cell OverridesEnables the selected cells of defined columns so that the values may be changedAny changes to the original properties are not be reflected in the cells
Clear Cell OverridesSets the value of the cells back to the property text derived values
Page 15© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Inserting UserDefined RowsInserting blank rows into derived tables (Parts List, Bend Table, and FOP table)
Rows may be inserted anywhere in a derived table
Sorting applies to the data displayed in the blank row
If inserted row is blank and sorting is enabled, the row may move because of the blank data in a sorted column
Page 16© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Convert Deleted Parts/Assemblies to User Defined Rows
When a part or assembly is deleted, the parts list is updated to make that row user defined, instead of removing rows when parts and/or sub-assemblies are removed from the assembly
The item number for the converted row remains
If disabled the rows are deleted when the parts list is updated
Page 17© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Display Controlthrough Configuration
Parts list display is based on a configuration, model view, or zone
Configuration is used to define what is displayed in the parts list
The Configuration combo box isdisabled and ignored when “Exploded list” is selected
Page 18© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Parts List – Merge Vertical Cellswith Same Value
Merge adjacent vertical cells in a column into a single cell
All tables (Parts List, FOP Table, and Bend Table)
Formatting optionsHorizontal alignment – Left, Center, Right, IndentVertical alignment – Top, Center, Bottom
DEMO 1
Page 19© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View CaptionsText and Color tab renamed to Caption
Page 20© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View CaptionsDrawing View style
Caption TypePrimary captionSecondary caption
Show – caption type displayed or not
Caption text - allows the userto enter the caption text for the selected caption type
Properties – Suffix, Annotation Sheet Number, View Scale, Angle of Rotation
Page 21© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View CaptionsFont – sets the font to be applied to the selected caption text
Font style – sets the style of the font to be applied to the selected caption text
Color – sets the color to be applied to the selected caption text
Separator – specifies whether there is a separator line between the primary and the secondary text
Alignment – specifies the alignment of the selected caption text
Aspect Ratio – sets the aspect ratio for the text in the selected caption
Page 22© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View CaptionsView Annotation Name – specifies the name for the view annotation
Annotation Sheet Number – specifies the sheet number annotation
View Scale – defines the text to be used for the view scale
Angle of Rotation – defines the angle of rotation for the view
Page 23© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Captions –Quick Bar
Show Caption – available in all view type Quick Bar
Shading option – changes from a horizontal bar to vertical bar in all view type Quick Bar
Page 24© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Captions –Viewing Plane
Text and Color tab has been renamed to Caption – all View Properties boxes
Same properties as Drawing View captionLeft arrow, Right arrowBoth arrows – displaycaption to the arrow
Page 25© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Captions –Auto-Naming AnnotationsDrawing views and drawing view annotations being placed have a specific order to the naming conventions. Auto-Naming of View Annotations allows the user to define the derived order to use
Specify Annotation Letters – specifies the letters to be used in the annotation andopens a new window for selections of annotation formatting
Page 26© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Captions –Auto-Naming AnnotationsTwo additional options:
Follow object creation sequenceFollow defined object sequence
If selecting “Follow defined object sequence”, the user is allowed to define the sequence
Page 27© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Captions –Auto-Naming AnnotationsUser can specify four different lists containing annotation letters and numbers
Lists can be alphanumeric
No repetitive characters allowed
Special characters (Tab, new-line,carriage-return, space, and escape) are not allowed
If the objects exceed the letters specified in the list, user has an option to continue the list appended with either the same letters or with 1, 2, 3….by selecting the subscript option
Page 28© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Delete Undo
Undo button is available if deleting the following:Drawing ViewsParts ListsBend Tables
DELET
E
DELET
EOOPS
!!!
OOPS!!!
Page 29© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Display (w/drag)Drawing view dragging displays the geometry of the drawing view while it is being dragged
Only the drawing view being dragged displays the geometry
Any other drawing view that is aligned to the drawing view being dragged still displays the drawing view range box
Page 30© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Display (w/drag)Show drag rectangle when full display time exceeds xx (milliseconds)
Specifies that drawing view geometry is displayed while moving (dragging) a drawing view, unless it takes longer than the specified time to move it. The default time limit is 200 millisecondsWhen the time limit is exceeded, an empty rectangle that represents the drawing view boundary displays instead of the drawing view geometry
Page 31© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Fixed PositionLock drawing view position
Quick barSelect view – Lock
Lock from view properties
DEMO 2
Page 32© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Break Lines Support for both horizontal and vertical breaks in the same view
Page 33© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Break Lines – Cylindrical and Short Break
Short break-Curved – controls for Height and Pitch
Short break-Linear – controls for Height and Pitch
Page 34© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Break Lines – Cropped EdgesDrawing View Properties dialog box General tab to show/hide the break lines. Thus when the break lines are hidden, we can show the cropped edges
Unchecked Checked
DEMO 3
Page 35© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Broken Out Section EdgesA Broken Out Section cutout is not a real cut on the parts. It is a drawing representation to accurately display internal structure of the parts
The edges produced by the outline of the Broken Out Section are displayed only as a boundary for the hatch/fill area
Cut edge is displayed with thin lines
Line style options available in view properties
DEMO 4
Option Off
Option On
Page 36© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Hatch Rib in Section ViewSolid Edge option - Enable/Disable the creation of hatch in ribs cut in section views
Option can be set to Hatch or No HatchHatch – Ribs are considered part of the primary body and will be cut along with the primary bodyNo Hatch – Ribs are considered to be a separate body
The ribs are pulled off of the primary body and cut separately
Page 37© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Hatch Ribs - Section Views option
New property added to the Drawing View – Advanced tab to allow the Hatch ribs setting to be specified on drawing views separately
When checked, ribs are hatched
When unchecked, the special rib non-hatched rib processing is done on the section view
Page 38© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Hatch Ribs - Criteria for Rib Processing
The following rules apply to hatching and not hatching ribsNot hatching ribs applies to section, revolved section, and broken out section drawing viewsA rib is added to the list of ribs for possible inclusion in the non-hatch processing when the following criteria are met
A segment of a cutting plane must intersect the ribThe normal cutting of the rib would produce a hatched face in the section view
Page 39© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Hatch Ribs – Broken out Section
Broken Out Section views have special considerations as followsThe Broken Out Section profile must be on the same view as the cut is appliedMultiple cutouts can be made on a single drawing view. The hatch/non-hatch display of a rib is the same and is controlled collectively across multiple cutouts
DEMO 5
Page 40© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Sheet ScaleSet Sheet Scale - two options to set the sheet scale
Manual scale - The sheet scale can be set manually using the “Scale”and “Scale value” and is not associated with any Drawing View scaleDrawing view scale - The sheet scale is derived from a drawing view and is associative with that view
By default, sheet has “Manual scale” until a drawing view is placed using Drawing View wizard
Page 41© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Sheet ScaleUser can change the derived sheet scale from other views using the “Set sheet scale” command
Command also located on the shortcut menu of Sheet tab
Page 42© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
DimensionsSupport for GB and ESKD templates
GB and ESKD styles added to Styles command
Page 43© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Dimensions – Override Pulled out Text
Text which is pulled off or out of a linear or angular dimension line is displayed according to the override Orientation and Position settings
Orientation - You can set the orientation to horizontal, vertical, perpendicular, or parallel with respect to the dimension linePosition - Sets the position of dimension text when it is pulled away from the dimension line
ST3 ST4
Page 44© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Dimensions - Degree Symbol on Angular Tolerance
Display the degree symbol to the angular tolerance value when angular tolerances are displayed
Page 45© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Dimensions - ISO/DIN Thread Dimension
Dimensions to a threaded diameter now display Hole Callout dataQuick Bar has a Hole Callout option
Supported by Draft, Sketch and PMI dimensions
Page 46© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Dimensions - Jogs to Dimension
Jogs can be added to Smart Dimension (linear, between two lines,diameter, etc.) and Distance Between dimensions that have two parallel linear projection lines
Adding jogs to projection lines is limited to the following dimension types:
Linear Dimensions.Symmetrical Diameter DimensionsCircular Diameter Dimensions (2 Projection Lines)
3D Dimensions in isometric views do not allow jogs
Supported in Draft, Sketch and PMI dimensions
Page 47© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Dimensions - Jogs to Dimension
Alt + click on one of the projection lines adds the jog
Jogs can be added to either or both projection lines
Multiple jogs may be added to each projection line
Alt + click on one of the key points associated with an inserted jog removes the jog
Page 48© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Dimensions - Zero Inch for Feet and Inch
When dimension units are set to feet-inch with fractional round off, a leading zero for the inch units will be displayed
Example, if the distance is 12.25 inches. The units set to feet-inch with fractional round off the readout would be "1-0 1/4" instead of the current "1-1/4"
Page 49© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Dimensions – Copy Attributes“Prefix Copier” as been rename to “Copy Attributes”
Dimension Styles can be copied from one dimension to another
DEMO 6
Page 50© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Style
A Drawing View Style Options Tabs
NameCaptionCaption FormatLines
Page 51© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Style
Name TabGives the style a name and description based on a standard
Page 52© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Style
Caption TabDefines caption content
Drawing ViewView AnnotationsProperties
Page 53© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Style
Caption Format TabSpecifies the appearance ofa drawing view caption andof a view annotation caption
FormattingLocation
Page 54© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Drawing View Style
Lines TabDefines the appearance of view annotations that use the drawing view style
Page 55© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Solid Edge Options - Drawing View Style
Drawing View Style – new option only exists in Draft
Use Drawing View Style Mapping - this is similar to the control on the ‘Use dimension style mapping’ on the ‘Dimension Style’ tab
Page 56© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Solid Edge Options - AnnotationNew Caption options
Show sheet number if parent annotation (e.g. cutting plane) and derived view (e.g. section view) do not reside on the same sheet
Displays a cross-reference between the sheet and the view annotation
Show drawing view scale if different fromsheet scale
When a drawing view is created that has a different scale than the sheet scale, automatically displays the drawing view scale in the caption
Show rotation angle if drawing view is rotatedIf a drawing view is rotated after placement, the rotation angle is displayed in the drawing view caption
Page 57© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation SymbolsNew ANSI ASME symbols and ISO equivalent symbols have been added to bring the standards up to date.
SymbolsTranslation -Independency -Continuous Feature -All Over -Volvo Oval -Volvo Rectangular –Taper Angle(4 directions) –Centerline –Parting Line –Symmetric Taper Angle(2 directions) –GB Rotated View Counterclockwise –GB Rotated View Clockwise -
Page 58© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation SymbolsNew JIS Weld Symbols
SymbolsJIS SpotJIS SeamKeyholeScarfStudContinuation fillet weld
Page 59© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation SymbolsSelect Symbols and Values Dialog
Areas to display Symbols and Values DialogModify Dimension StyleDimension PropertiesDimension PrefixHole TableBend Table PropertiesFeature Control Frame PropertiesCallout PropertiesGOST Weld Symbol PropertiesProperty Text DialogDrawing View PropertiesText Box
Page 60© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation - Auto balloon –Fastener Systems
Stack fastener system balloons automatically
You can do this when placing a balloonedparts list or when adding balloonsmanually with the Balloon command
Page 61© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation - Auto balloon –Fastener Systems
You can arrange fastener systemballoons automatically in horizontalor vertical stacks
Text alignment can only be used withthe “underline” balloon type
DEMO 7
Page 62© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation – Callout aspect ratioFull text formatting capabilities are available for all callouts in the Draft environment and for model PMI
Enhancements to Callout Properties Specify Aspect Ratio to charactersin a Callout
Page 63© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation – Callout aspect ratioShow border outline - Displays a border around the callout text
Gap between border and textHorizontal - Specifies the spacebetween the callout text and thehorizontal edges of the border onthe calloutVertical - Specifies the spacebetween the callout text and thevertical edges of the border on thecallout
Fit width to contents - Automatically sizes the width of the callout box to its contents. Use this option to ensure that resolved property text always fits into an allotted space, such as in a title block cell in a drawing border
Page 64© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation – Callout aspect ratioFixed width - Maintains the width of the calloutto be exactly the value specified in theadjacent box
Automatically adjust aspect ratio – Changesthe width of the characters in the callouttext, without changing their height.The new aspect ratio is applied to all of thecharacters in the callout text box, not justthe characters that exceed the specifiedcallout width
Page 65© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation – Callout aspect ratioCalculated aspect ratio - Displays the current aspect ratio of the characters in the callout
Wrap text - Automatically word-wraps thetext that extends beyond the specifiedline width. A new line is started each timeone or more characters in a word exceedthe width of the callout box
All options are available for ‘PMI Callouts’ (included in the drawingview from model view)‘Draft Callouts’ in Draft environment ‘PMI Callouts’ in Part environment
Page 66© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation – Callout aspect ratioCallout Quick Bar
Resizing CalloutThe user can resize onlythe width of the Callout
The height automatically changes once the user selects the wrap text option and reduces the width
Page 67© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Annotation – Callout aspect ratioLeader attachment and Leader handles
Handle for resizing the break line is located at the attachment point of break-line and border. This handle also flips the leader attachment to front (right) or back (left) of the Callout. The handle is not available when there is no break
DEMO 8
Page 68© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Feature Control Frames - HandlesFeature Control Frame (FCF) handles consistent with other annotation handles
Resizing the break line, flipping the leaderattachment and moving the break linealong the FCF borderAlt+drag break line handle for snapping to FCF key-points
Select the FCF and move freely anywhere on the screen
FCF has nine snap-points. Located at corners, midpoints of each side and one at center of the divider
Page 69© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Feature Control Frames –Orientation
Horizontal Vertical Perpendicular Parallel
Page 70© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Feature Control Frames - FlippingFlip the FCF at 90 and 270 degrees when attached to an entity without leader
Page 71© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Feature Control Frames -Composite
Increase the number of input fields to four lines
Each line has the option merge the composite with the upper line
DEMO 9
Page 72© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box - Stack‘Stack’ button added to the Text Box Quick Bar to support insertion of fraction
Text – content to be stackedUpperLower
Style - Specifies the arrangement of stacked text or numbers
Stacked, Tolerance, Skewed, and Linear
Align normal text with - specifies how the surrounding, normal text is aligned with the stack
Page 73© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box - StackSize of text relative to font size - specifies the font size of the stack as a percent
Auto Stack - applies stack formatting automatically to numbers and symbols as you type
Page 74© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box – Bullets and Numbering Support for Bullets and Numbers
Choose the type listBullets (and select type of bullet) NumberedNo list
Numbered listRestart at “1”Continue Numbering
Bullet and Numbered listDecrease IndentIncrease Indent
Page 75© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box – Bullets and Numbering By default the Bullets and Numbered list has a left indent of half-tab stop value and a hanging indent of half-tab stop value
At the end of the bulleted paragraph, when you hit ENTER to create a new paragraph, the bulleted list continues
When finished with your bulleted list,press ENTER and then select the‘No List’ option to turn off bullet formatting
Page 76© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box – Bullets and Numbering Start at - Specifies the first number in the numbered list
The default is 1
Specifies the numbering format. Formats available:
11. 1)(1)
Page 77© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box – Bullets and Numbering Increase Indent - increases the indentation of the current paragraph or the selected paragraphs
Decrease Indent - decreases the indentation of the current paragraph or the selected paragraphs
Page 78© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box – Bullets and Numbering When the bullets/numbers are SELECTED, the following changes for these bullets/numbers can be made:
Text ScaleFont (Only for numbers. Not for bullets.)Font SizeColor BoldItalicUnderlineJustificationIndentsChange to bulleted list or numbered list or no list.
Page 79© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box – Text Style New Indent and Spacing tab in the Text Style
Page 80© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box – Fixed Width Text Box Text size is managed within the text box border, option available in the Quick Bar
Fit to Content – automatically sizes the width of the text box border to its contentsFixed Adjust Aspect Ratio – adjusts text size automatically to maintain the fixed width and height Fixed Wrap Text – automatically word-wraps the text that extends beyond the specified line width
Page 81© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box – Insert Characters
Page 82© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Text Box – JustificationText Box Justification has nine options for justification
Quick Bar Justification has the same nine options
DEMO 10
Page 83© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Reattach CenterlineWhen centerlines become detached, they change color to the detached color like a dimension
Dimension Tracker lists the detached centerline annotation
If centerline was created with the (by 2 lines) type and the centerline becomes detached, it maintains the (by 2 line) type
Page 84© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Reattach CenterlineNew handles added to reattach centerline to changes in the drawing viewDrag both handle to reattach to update centerline
DEMO 11
Page 85© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Reattach Center Mark and Bolt Hole Circle
When center marks/bolt hole circle become detached, they change color to the detached color like a dimension does
Dimension Tracker lists the detached center marks/bolt hole circle annotation
A center marks/bolt hole circle become detached when a feature has been deleted
Page 86© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Reattach Center Mark and Bolt Hole Circle
Drag handles to reattach center marks/bolt hole circle to changes in the drawing viewDrag dimension handles to reattach to update detached dimensions
Page 87© 2011. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM SoftwareReturn to Topics
Reattach Center Mark and Bolt Hole Circle
Centerline handles can be reattached to any geometryATL+drag detachs and drops on new location
DEMO 12
© 2011. Siemens Product Lifecycle Management Software Inc. All rights reservedSiemens PLM Software
Thank You!