12
Solenoid-Based Focusing Lens for a Superconducting RF Proton Linac Presentation prepared for AEM 11/08/2010 1 I. Terechkine

Solenoid-Based Focusing Lens for a Superconducting RF Proton Linac Presentation prepared for AEM 11/08/20101I. Terechkine

Embed Size (px)

Citation preview

I. Terechkine 1

Solenoid-Based Focusing Lens for a Superconducting RF Proton

Linac

Presentation prepared for AEM

11/08/2010

I. Terechkine 2

Content:

• Why solenoids are used for focusing;• Main requirements and design features;• Lens testing / certification;• Quench protection studies;• Fringe magnetic field;• Alignment verification scheme

11/08/2010

I. Terechkine 3

Focusing by SolenoidsMotivation: 1. Potentially lower rate of emittance growth 2. Axially symmetric focusing3. Relaxed alignment requirements

11/08/2010

effceffcR LB

eVTqm

LBc

q

m

v

cRf

2222

2

2 )(81

4

Focusing length:

Radial component of a fringe field combined with asymmetric particle rotation (Bush theorem) provides radial component of the particle velocity; hence the focusing effect in short lenses

Limitation:Low energy of protonsOnly front end of RF linacs can use solenoid-based lenses

I. Terechkine 411/08/2010

Prototype Cryomodule Layout

• Limited longitudinal space• Superconducting RF structures do not tolerate magnetic field – hence thorough shielding

I. Terechkine 5

Main Requirements

11/08/2010

Requirements for focusing strength, lattice period, and bore diameter are based on beam propagation modeling made with the goal of beam loss reduction in mind.

Requirement for the bending strength of steering dipoles is based on the assumed accuracy of lens alignment

Focusing Lens•Integrated squared field - 3 T2-m•Bore Diameter - 30 mm•Insertion Length - 220 mm•Fringe Magnetic Field - 10 μT•Alignment accuracy - ~200 μmDipole Correctors•Bending Strength - 0.005 T-m

Lens design requirements are based on results of beam propagation modeling

I. Terechkine 6

Focusing Lens Design Approach

11/08/2010

I. Terechkine 7

Focusing Lens Assembly

11/08/2010

I. Terechkine 8

Tests and Measurements• Performance Test• Magnetic Field Mapping• Magnetic Axis Position• Cryogenic Performance

11/08/2010

I. Terechkine 9

Quench Protection StudiesIn a case when quench (transition of the superconducting strand from the superconducting state to the normal state) occurs in a bucking coil, there exists a danger of irreversible degradation of the strand properties due to overheating or damage by an electrical arc (just imagine the recent problem of the LHC magnetic system brought to much low scale). Required reliability of an accelerator demands reliable operation of all focusing lenses. Protection measures must be carefully studied and implemented.

11/08/2010

Algorithm of quench propagation modeling Layer Voltage Coil Voltage

Coil Temperature

I. Terechkine 10

Magnetic Shield EffectivenessBecause the fringe magnetic field must be very low (10 µT or 0.1 G), verification of this condition required making special magnetic measurements. Background field level should be made sufficiently low and the measurement method ought to provide needed sensitivity. A horizontal cryostat made for SRF cavity testing was used. It was equipped with mu-metal magnetic shield, and the field level in the center of the cryostat was ~2 µT.

11/08/2010

I. Terechkine 11

Lens Alignment Verification

11/08/2010

Camera Camera

Beam Splitter with Partial

Mirror Partial

Retroreflector

Cryostat Window

Cyrostat Window

Laser

Pressure Vessel

Solenoid

CCD Camera: 1 µm resolution Corner ReflectorLaser

Poisson Reference Line

I. Terechkine 12

Conclusion

11/08/2010

• Design and prototyping of lenses for installation in cryomodules of HINS linac – complete;• Some modifications are in consideration for lenses of the PX linac (e.g switch to 2K LHe temperature and relaxation of requirements for the fringe magnetic field);• Alignment system (including technology and methods) is being studied; Long Base Alignment experiment (in progress) will provide additional information about achievable accuracy.