GENERATION PROFILE SOLAR PCU CHARGING PROFILE WITH SOLAR PRIORITY
PWM Range - Single Phase: 3K VA/48VIt is an integrated system consisting of a Solar Charge Controller, Inverter and a Grid charger. It has inbuilt intelligence to utilize the solar power on priority. Working Principle Solar PCU converts energy from solar panel as the first priority and incase the solar power can not support the load grid power is used to charge the battery and supply load.
Single Phase PWM Range
Features• Pure sine wave output• In-built heavy duty Solar charge Controller• Excellent overload capabilities• Optimal battery protection• Best reliability• High reliability with Minimal maintenance• Grid charging enable disable option• Solar and Grid charging current sharing for maximum solar usage• User set-able Solar Mains Battery (SMB) and Solar Battery Mains (SBM) operationsElectronic Protection updates• Battery low protection• Battery over voltage shutdown• Over temperature and overload protection• Short circuit protection• Reverse polarity protection by internal fuse
• Acoustic alarm in various warning conditionsDisplays• Display showing PV & Inverter output• LCD showing various input and output parameters such as •Output voltage •load •input voltage •battery voltage •PV voltage •current with cumulative solar energy.Operation• Short circuit , over load & over heating protection• Automatic Charger Restart Time after High CurrentRemote Monitoring Software• Remote monitoring through RS232, Ethernet, GSM, GPRSCertification & patents• IEC61683, IEC60068-2-1,2,14,30,31 (N/A for 6H24); IEC62093 certification
56
Solar Power Conditioning UnitSingle Phase PWM Range
Type Single Phase Solar Power Conditioning Unit
Technology DSP Based PWM Technology
Ratings 3KVA
PV Charge Controller Rating 3kWp
Model No. PCU2K48
Power device IGBTs cum MOSFETs
INVERTER
INPUT PARAMETERS
Nominal I/P Voltage 48V
Input Voltage Range DC 44V-60V ±2%
Low Battery cut off 44V ±2%
High Battery shutdown 65V ±2%
No load shutdown ON/OFF (Factory Permanent OFF after 5minutes if load is ≤�40W
settable as per customer requirement)
OUTPUT PARAMETERS
Voltage Regulation at nominal voltage 230 ± 5%
Frequency Regulation 50Hz ± 0.2Hz
Efficiency (typical)at linear load >85% (linear load)
Output Waveform Pure Sine Wave
Total Load 2kW@UPF
Overload 200% for 8seconds
THD (on Linear Load) <3% (linear load)
Power usage Priority From Photovoltaic Array
Crest Factor 3:1
GRID CHARGER
Grid I/P Voltage Range WW-155 VAC-280VAC±10V and NW-185 VAC-265VAC±10V
Charging Current Max. 30Amp + 2Amp ( Factory settable)
SOLAR CHARGE CONTROLLER
Type Series Regulator Common Negative
Maximum I/P PV Voltage 25V Per 12V Solar Panel
Solar Array Single Array
Charging Current Imax. > 30A
Bulk Voltage 57.6V ±2%
Adjustable Bulk Voltage 53V-60V
Transition from float to bulk Below float level for a cumulative period of 1 hour
Float Voltage 54V ±2%
Protection Over Current, Battery over Charge Protection, PV/Battery Reverse Polarity, Reverse Current Flow, High Temp.
OTHER SPECIFICATIONS
LCD massage Indications for PV voltage, Battery Voltage, Output Voltage, Output Frequency,
Output Current, Charging Current, Charging Mode, High Temp., High Current, Array Reverse Polarity etc.
Operating Temp. 0°C to + 45°C
Storage Temp. 0°C to + 55°C
Acoustic Noise < 60dB
Relative Humidity 0-95% Non-Condensing
Weight 61 kg
Dimensions (w x d x h) 351x617x320 mm
TECHNICAL SPECIFICATIONS
57
Solar Power Conditioning Unit
GENERATION PROFILE
Single Phase PWM Range
PWM Range - Single Phase: 3KVA/96VIt is an integrated system consisting of a Solar Charge Controller, Inverter and a Grid charger. It has inbuilt intelligence to utilize the solar power on priority. Working Principle Solar PCU converts energy from solar panel as the first priority and incase the solar power can not support the load grid power is used to charge the battery and supply load.
SOLAR PCU BASED INSTALLATION DIAGRAM
OR
PV GENERATOR Load
Storage Battery
POWER
CONDITIONING UNIT
GridGenerator
Features• Pure sine wave output• In-built heavy duty Solar charge Controller• Excellent overload capabilities• Optimal battery protection• Best reliability• High reliability with Minimal maintenance• Grid charging enable disable option• Solar and Grid charging current sharing for maximum solar usage• User set-able Solar Mains Battery (SMB) and Solar Battery Mains (SBM) operationsElectronic Protection updates• Battery low protection• Battery over voltage shutdown• Over temperature and overload protection• Short circuit protection• Reverse polarity protection by internal fuse
• Acoustic alarm in various warning conditionsDisplays• Display showing PV & Inverter output• LCD showing various input and output parameters such as •Output voltage •load •input voltage •battery voltage •PV voltage •current with cumulative solar energy.Operation• Short circuit , over load & over heating protection• Automatic Charger Restart Time after High CurrentRemote Monitoring Software• Remote monitoring through RS232, Ethernet, GSM, GPRSCertification & patents• IEC61683, IEC60068-2-1,2,14,30,31 (N/A for 6H24); IEC62093 certification
TECHNICAL SPECIFICATIONS
58
Solar Power Conditioning UnitSingle Phase PWM Range
Type Single Phase Solar Power Conditioning Unit
Technology DSP Based PWM Technology
Ratings 3KVA
PV Charge Controller Rating 3kWp
Model No. 3K96
Power device IGBTs cum MOSFETs
INVERTER
INPUT PARAMETERS
Nominal I/P Voltage 96V
Input Voltage Range 88V-120V ±2%
Low Battery cut off 88V±2%
High Battery shutdown 130V ±2%
No load Power Consumption with Less than 15W
No load shutdown enable
No load shutdown ON/OFF (Factory If the load is <60W, Output 5sec ON and 50sec OFF every cycle.
settable as per customer requirement)
OUTPUT PARAMETERS
Voltage Regulation at nominal voltage 230 ± 5%
Frequency Regulation 50Hz ± 0.2Hz
Efficiency (typical)at linear load >85%
Output Waveform Pure Sine Wave
Total Load 3kW@UPF
Overload 200% for 8seconds
THD (on Linear Load) <5%
Power usage Priority From Photovoltaic Array
Crest Factor >3:1
GRID CHARGER
Grid I/P Voltage Range WW-155 VAC-280VAC±10V and NW-185 VAC-265VAC±10V NW-190-265±10V
Charging Current Max. 30Amp + 2Amp ( Factory settable)
SOLAR CHARGE CONTROLLER
Type Series Regulator Common Negative
Maximum I/P PV Voltage 25V Per 12V Solar Panel
Solar Array Single Array
Charging Current Imax. >30A
Bulk Voltage 57.6V ±2%
Adjustable Bulk Voltage 106-120V
Transition from float to bulk Below float level for a cumulative period of 1 hour
Float Voltage 108V ±2%
Protection Over Current, Battery over Charge Protection, PV/Battery Reverse Polarity, Reverse Current Flow, High Temp.
Automatic Charger Restart Time 3.5 Minutes
after High Current
Cooling Forced air
OTHER SPECIFICATIONS
Indications Indications for PV voltage, Battery Voltage, Output Voltage, Output Frequency,
Output Current, Charging Current, Charging Mode, High Temp., High Current, Array Reverse Polarity etc.
Operating Temp. 0°C to + 45°C
Storage Temp. 0°C to + 55°C
Acoustic Noise < 60dB
Weight 61 kg