XB200205 1805 Ver1 / 1912
Powered by Solar EnergyDrive Your Green Future
Solar Drive for PumpRM6F5 Series 0.75kW-22kW
Fault ProtectionBuilt-in MPPT Dual power Automatic Start/Stop
PV Cell
Power Grid AC/DCSwitch
Solar Motor Inverter
Water Pump
Aerator
DC Power
AC Power
AC DC
High energy efficiency, reduces your carbon footprint.
Fully automatic system, uses variable speed drives compatible with AC, 3-phase, submersible and surface mount pumps.
As it is more efficient to store water than to store electricity, energy storing devices (eg. batteries) are excluded from the system.
The system is prepared to be incorporated with an elevated water storage, e.g. a water tower or an uphill tank installation.
Product series
Maximum Applicable Motor(HP)
Application: Solar Motor Inverter
Input Voltage2: AC 200~240V or DC 125~400V4: AC 380~480V or DC 270~800V
Features of Solar Pump Inverter System Description
Application
Irrigation of landDemostic WaterSupply
Fishing FarmingSwimming PoolFountain Livestock
Built-in MPPT (Maximum Power Point Tracking), maximizes your power output.
Supports dual power mode from 3Φ or 1Φ AC power or DC power of solar arrays.
Built-in pump protection function in case of dry run, over pressure…etc.
Automatic start and stop according to sunrise and sunset or sudden power cuts.
Automatic start and stop function is compatible with level sensors, capable of controlling water level inside the overhead tank.
Model Number Scheme
RM6F5-2 001-0713
Standard Specifications
Modle Name (RM6F5-□□□□)
200V Series 400V Series
Maximum Applicable Motor (HP/kW)
2001 2002 2003 2005 2007 2010 2015 2020 4001 4002 4003 4005 4007 4010 4015 4020 4025 4030
1/0.75
1.6
4.2
2/1.5
2.6
6.8
3/2.2
3.8
10
5/3.7
5.8
15.2
Three-Phase 200~240V
176~264V 50/60Hz /±5% 332~528V 50/60Hz /±5%
120% of drive rated output current for 1 min 120% of drive rated output current for 1 min
IP20 IP20
Fan cooling Fan coolingNaturecooling
Naturecooling
0.1~120.0Hz
Three-Phase 380~480V
0.1~120.0Hz
3ø 200~240V 50/60Hz ; DC 125~400V 3ø 380~480V 50/60Hz ; DC 270~800V
7.5/5.5
9.5
25
10/7.5
12
31
15/11
16
42
20/15
22
58
1/0.75
1.9
2.5
2/1.5
2.7
3.5
3/2.2
3.7
4.8
5/3.7
6.1
8
7.5/5.5
8.4
11
10/7.5
13
17
15/11
17
22
20/15
23
30
25/18.5
28
37
30/20
34
45
5 8 12 18 30 41 55 66 3 4.2 5.8 9.6 13 20 25 38 42 52
1.8 1.8 1.9 2 3 3 5.4 5.7 1.8 1.8 1.9 2 2 3.1 3.1 5.6 5.7 5.8
Rated Output Capability (kVA)
Rated Output Current (A)
Rated Output Voltage (V)
Range Of Output Frequency (Hz)
Power Source (ø, V, Hz)
Input Current (A)
Permissible AC power source fluctuation
Overload Protection
Cooling Method
Protective Structure
Weight/Mass(kg)
Case Code Case 1 Case 1Case 2 Case 2 Case 3Case 3
System Structure
A
A
B
B
C D C
D