Smart SolutionsIntelligent, integrated infrastructure for the data center
1
Infrastructure Management
Heat Density
Availability
Energy Efficiency
Power Density
Top Data Center Challenges
Source: Data Center Users’ Group Survey
Virtualization,Cloud
Increasing Demand
Reduced Budget
Higher Density
Regulation Compliance
IT Outsourcing Consolidation
Efficiency & Green
initiatives
External forces
changing the business climate
Business & technology
forces pressing on the data
center
Facility Challenges
2
Data Center Lifecycle Efficiency
Design & Deployment Increase energy efficiency Reduce capital costs Reduce space Faster deployment Lower engineering costs Improve design efficiency
Operation Free up stranded capacity Increase availability Reduce energy costs with
efficient technologies
Management Streamline operations with
management controls Improve asset utilization Simplify change management Lower long-term operational
costs with proactive maintenance programs
Efficiency Without Compromise™
Design & Deployment
OperationManagement & Planning
Efficiency is not just lowering operating costsEfficiency should apply to all aspects of operations
Smart Solutions Family
4
Smart SolutionsFrom Emerson Network Power
An integrated data center infrastructure– Power, Cooling– Racks, Power Distribution – Infrastructure and IT Management
What makes these solutions unique?
• Optimized planning, monitoring and management
• Control your IT environmentControl
• Simple and flexible design and implementation• Systems work togetherInteroperable
• Make use of existing infrastructure• Avoid expensive room upgradesEconomical
• Enhance business, space, energy efficiency• Rapid deployment, easy servicingEfficient
5
Industry Best Practices for Data Center Design and Operation
Smart Solution infrastructure integrates industry best practices in data center design and operation:
– Air flow management: Hot aisle / cold aisle; cold aisle containment– High availability, high efficiency UPS– Highest efficiency precision cooling; variable capacity /intelligent
controls– Space-savings, minimal footprint – Modularity for flexibility and easier expansion– Integrated monitoring and control for efficiency in
planning and management– Unique local service for design audits, configuration
support, installation support, maintenance and repair
6
SmartRowTM
7
Introducing SmartRowTM
Applications• Capacity: 20kW• Racks: 3-6• Floor: Primarily non-raised• Key Applications: Small data
centers; remote sites
Needs Addressed• Integrated design• Standardization• Low 1st cost & operating cost• Availability• Speed of deployment
Intelligent, integrated infrastructure in a self contained line-up
8
SmartRowTM - What is it?Single line of racksComplete and integrated
data center infrastructure– 3-6 racks (up to 20kW)– Integrated Cooling– Airflow Management– Fire Suppression– UPS– Power Distribution– Monitoring
9
SmartRowTM - Component Details High efficiency precision cooling
– Downflow 5-Ton Liebert Challenger– Air, Water/Glycol or Chilled Water
Supply air plenum Fire suppression Integrated electrical panel Monitoring Panel Reliable on-line UPS Cool air up front of racks Knurr DCM racks Rack PDU Return air plenum Back up cooling Room connections Start-up Full 1-yr warranty
10
SmartRowTM Benefits
• Monitors temperature and controls precision cooling operating levels accordingly
• Monitors equipment for quicker response & resolutionControl
• Can be deployed in just weeks: simple in design & deployment
• Local data center experts and service teams for configuration, installation, maintenance, repair
Interoperable
• Room neutral: No effect on existing space• Reduce cost of installation: no need to undertake expensive
upgrades to fire suppression, cooling capacity or flooringEconomical
• Significant energy savings from enclosed precision cooling system, variable capacity and intelligent controls
• Optimizes space efficiency through integrated systemEfficient
11
SmartRowTM Design & Cost Example
Conventional Design18 kW, 288 sq ft1 rows, 6 racksCeiling mounted ducted cooling(6) 5 kVA UPSRoom renovation, fire suppression
Situation: deploy 18 kW of IT to a non-IT ready room
SmartRow18 kW, 288 sq ft1 rows, 6 racks1 Liebert Challenger (downflow)6 Liebert GXT 5 kVARoom neutral
12
Conventional SmartRow Cost Savings % Savings
Room Costscontractor, installation, engineering services
$60,000 $43,000 $17,000 28%
Infrastructure EquipmentUPS, distribution, cooling, racks, fire suppression
$105,000 $109,000 -$4,000 -3%
Total CapEx $165,000 $152,000 $13,000 8%
Annual Energy Consumptionpower & cooling equipment energy use
$8,800 $6,400 $2,400 27%
5 Year OpEx $44,000 $32,000 $12,000 27%
5 Year TCO $209,000 $184,000 $25,000 12%
SmartRowTM Cost Comparison
Room Savings
Equipment Savings
Energy Savings
Room neutral, fewer services to retrofit room into an IT space
Pre-engineered, integrated precision cooling, ducting, distribution and fire suppression
Airflow management, variable capacity, intelligent controls
13
SmartModTM
14
Introducing SmartModTM
Segment Profile• Capacity: 30-400kW• Racks: 6-28• Floor: N/A• Applications: Supplemental
capacity; remote data centers; disaster recovery
Needs Addressed• Simplicity
– Fully integrated design• Flexibility & Availability
– N, N+1 or 2N• Standardization• Speed of deployment
Intelligent, integrated infrastructure in a rapid- deployment enclosure
15
SmartModTM - What is it?Rapid deployment IT enclosure
– Racks– Distribution– UPS– Precision Cooling & Condenser– Transfer Switch– Fire Suppression– Monitoring & Management
Server Neutral
16
Specifications 30 kW 90 kW (or 75kW N+1)
ComponentsCooling, UPS, distribution,
fire & monitoringCooling, UPS, distribution,
fire & monitoringInput Voltage 480 or 208 VAC 3-Phase 480 or 208 VAC 3-PhaseRack Space 9 racks, 378 U 8 Racks, 336 U Density 3.33kW / rack 11.25kW / 9.3kW per rackTotal IT Load 30 kW 90kW – N / 75kW – N+1Power Redundancy N+1 N or N+1Cooling Redundancy N+1 N or N+1Footprint 11.5’W x 40’L 11.5’W x 53’LHeat Rejection Equipment Integrated Integrated
SmartModTM 30-90 kW Component Details
17
30kW SmartMod 90kW / 75kW SmartMod
IT Container 200 kWInput Voltage 480 VAC 3-PhaseRack Space 14 racks, 588UDensity 14 kW / rackTotal IT Load 200 kWPower Redundancy N or 2NCooling Redundancy N+1Footprint 11.5’W x 53’LHeat Rejection Equipment
Chilled Water or External for DX
18
Power Container 200 kW 400 kW
In /out Voltage480 VAC 3-
Phase480 VAC 3-
PhaseTotal IT Load 200 kW 400 kWPower Redundancy N or 2N N or 2NCooling Redundancy 2N 2NFootprint 11.5’W x 40’L 11.5’W x 53’LHeat Rejection Equipment
External Condensers
External Condensers
SmartModTM – 200 kW Component Details
200kW SmartMod IT Enclosure 200kW SmartMod Power Enclosure
SmartModTM - Applications Capacity Overflow
– Short term: bridge until expansion or new data center is completed– Long term: modular data center, grow as you need it
Remote locations– Designed with secure access, remote monitoring– All weather construction– Where chilled water is not available
Disaster recovery– Utilize for short term capacity overflow then re-deploy as DR
– That doesn’t solve the problem: lack of extra power and cooling– SmartMod makes the difficult part easy: power & cooling
Other containers: “just give me X amount of reliable power and chilled water and I can plug in my pod”
19
SmartModTM Benefits
• Remotely monitor infrastructure and environmental conditions• Remotely monitor security and accessControl
• Pre-engineered infrastructure, designed and matched for the most common data center densities
• Management software integrates with existing systems• Local data center experts and service teams for configuration,
installation, preventive maintenance, repair
Interoperable
• Doesn’t burden existing power and cooling infrastructure• Reduce cost of installation: no need to undertake expensive
expansion of existing data center or construction of new data center
Economical
• High-efficiency power and cooling technologies reduce power consumption versus conventional data centers
• Pre-engineered systems, can be installed in just monthsEfficient
20
SmartModTM Design & Cost Example
Conventional Design75 kW, 921 sq ft1 row, 13 racks3 perimeter cooling units (N+1)(2) 100 kVA UPS (N+1)Build a new building
Situation: build a space for 75 kW of IT
SmartMod75 kW, 609 sq ft1 row, 8 racks4 Liebert CRV (N+1), iCOM1 Liebert APM 90 kVA UPS (N+1)Deploy enclosure
21
Conventional SmartMod Cost Savings % Savings
Room Costscontractor, installation, engineering services
$579,000 $84,000 $495,000 85%
Infrastructure EquipmentUPS, distribution, cooling, racks, fire suppression
$315,000 $772,000 -$457,000 -145%
Total CapEx $894,000 $856,000 $38,000 4%
Annual Energy Consumptionpower & cooling equipment energy use
$31,000 $22,000 $9,000 29%
5 Year OpEx $155,000 $110,000 $45,000 29%
5 Year TCO $1,049,000 $966,000 $83,000 8%
SmartModTM Cost Comparison
Room Savings
Equipment Savings
Energy Savings
Pre-engineered, no room, utilize enclosure, costs related to install and start up
Equipment costs are the enclosure; which is the entire data center
Airflow management, EC fans, digital scroll, intelligent cooling controls, no chilled water
22
SmartAisleTM
23
Introducing SmartAisleTM
Applications• Capacity: Most cost effective
up to 400kW• Floor: Raised, non-raised• Applications: Small and
medium data centers; high-density zones
Needs Addressed• Efficiency: OPEX & CAPEX• Flexibility• Availability• Standardization• Interoperability
Intelligent, integrated infrastructure using row-based building blocks
24
SmartAisleTM - What is it?Approach which combines the many disparate
parts of the IT infrastructure… • Racks• Rack PDUs• Busway• Power Distribution
• UPS• Precision Cooling • Cooling Controls• Containment
• Monitoring: Rack & Row• Out of Band Management• Startup and Maintenance• Other services
25
SmartAisleTM - What is it?Approach which combines the many disparate
parts of the IT infrastructure…
…into a connected system which works together to improve cost, availability and management
• Liebert CRV • Knurr racks• Liebert APM• Cold Aisle Containment
• Liebert MPX• Liebert MPH• Liebert Nform / Site Scan • Liebert MB Busway
• Avocent appliances• Assessment services• Liebert Installation / Startup• Liebert PM services
26
SmartAisleTM - Component Details Power
Rack PDU
Racks
InfrastructureManagement
MonitoringLCD
Console
Avocent Data Center Planner Avocent DS View
Liebert APM
Liebert CRV
AlarmsSensors
DetectorsLiebert iCom
Liebert RDU
Liebert Nform
Knürr DILiebert MPX, MPH
Knürr DCM
Liebert MB
Avocent Service Processor Manager
AvocentKVM
Switch
AvocentSerial
Console
Avocent PM
Cooling
27
SmartAisleTM Benefits
• Streamlines IT planning to optimize space / capacity utilization• Monitors equipment to reduce break/fix events• Monitors power, temperature and humidity and controls
equipment operating levelsControl
• Racks, cooling, power modules fit together for easy design and change management
• Local data center experts and service teams for configuration, installation, preventive maintenance, repair
Interoperable
• Can be used to retrofit existing infrastructure to support higher capacity and density
• Modular design lets you pay only for what you need todayEconomical
• Increase energy efficiency using high-efficiency row-based cooling systems and containment
• Streamlines IT productivity through management software and remote monitoring and control of infrastructure systems
Efficient
28
SmartAisleTM Design & Cost Example
Conventional Design160 kW, 1482 sq ft3 rows, 27 racks4 perimeter cooling units(1) 200 kVA UPS3 distribution cabinets
Situation: deploy 160 kW of IT to a floor
SmartAisle160 kW, 870 sq ft2 rows, 16 racks4 Liebert CRV, iCOM, Containment2 Liebert APM 90 kVA UPSLiebert MB busway
29
Conventional SmartAisle Cost Savings
% Savings
Room Costscontractor, installation, engineering services
$515,000 $459,000 $56,000 11%
Infrastructure EquipmentUPS, distribution, cooling, racks, fire suppression
$415,000 $391,000 $24,000 6%
Total CapEx $930,000 $850,000 $80,000 9%
Annual Energy Consumptionpower & cooling equipment energy use
$63,600 $46,600 $17,000 27%
5 Year OpEx $318,000 $233,000 $85,000 27%
5 Year TCO $1,248,000 $1,083,000 $165,000 13%
SmartAisleTM Cost Comparison
Room Savings
Equipment Savings
Energy Savings
Pre-configured = less engineering, easier install
Less cooling equipment with containment, fewer racks, less distribution, modular UPS
Airflow management, EC fans, digital scroll, intelligent cooling controls, containment
30
Smart Solutions SmartRowTM SmartModTM SmartAisleTM
Ideal Applications Non-traditional spaceDisaster recovery
Non-traditional spaceDisaster recovery Auxiliary capacity
Data CenterHigh Density Pod
Capacity 20 kW 30-90 kW200-400 kW
Most cost effective up to 400 kW
kW per Rack 2 to 4 kW / rack 5 to 14 kW / rack 5 to 30 kW / rack
Key BenefitsFully integrated,
standalone room-neutral system
All in one design, just add servers and
network connection
Standardized solution building
blocks
Example Layout
Smart Solutions - Summary
31
Smart SolutionsFrom Emerson Network Power
How will data center needs be met?
Smart solutions for efficient design
• Optimized planning, monitoring and management
• Control your IT environmentControl
• Simple and flexible design and implementation• Systems work togetherInteroperable
• Make use of existing infrastructure• Avoid expensive room upgradesEconomical
• Enhance business, space, energy efficiency• Rapid deployment, easy servicingEfficient
Around technology on a box-by-box basis?
Around a data center wide approach to efficient design?or
32