SLOKKEVANNUTFORDRINGER SETT FRA VANNFORSYNINGEN
SAMSPILL MELLOM DE KOMMUNALE
ETATENE/VIRKSOMHETENE
VANNFORSYNINGENS BIDRAG OG UTFORDRINGER
VIKTIGHETEN AV OVERTRYKK MOT
INNSUGINGSFAREN/TILBAKESTRØMSIKRING
INNTRYKK FRA KURS I BERGEN OM SLOKKEVANN
PER OLE BRUBAK
.
2
KAP. 4, § 21 VANNFORSYNING-SAMSPILL-
SISTE AVSNITT:
• KOMMUNEN MÅ HA GODE RUTINER FOR HVORDAN DE SKAL IVARETA
SITT OVERORDNEDE ANSVAR VEDRØRENDE SLOKKEVANN OG VANN
TIL AUTOMATISKE SLOKKEANLEGG. SLIKE RUTINER KAN VÆRE ET
VERKTØY FOR SAMARBEID MELLOM DE KOMMUNALE ETATENE SOM
FORVALTER BRANNMYNDIGHET, VANN- OG AVLØP,
BYGNINGSMYNDIGHET OG PLANMYNDIGHET, OG SØRGE FOR AT
ETATENE OPPTRER ENHETLIG MED HENSYN TIL FORVALTNING AV
BRANNSLOKKEVANN.
Tittel på presentasjon 2
SAMSPILL OM SLOKKEVANNNÅR ER DET VIKTIG MED SAMSPILL?
• KOMMUNEPLANENS AREALDEL
• DELINGSSAKER.
• REGULERINGSSAKER OG UTBYGGINGSAVTALER.
• BYGGESAKER.
• SANERING AV EKSISTERENDE VANNFORSYNINGSANLEGG.
• KONTROLL, DOKUMENTASJON, FERDIGATTEST OG OVERTAGELSE
HVEM HAR DETTE SAMSPILLET? HVEM ER KOMMUNENS
«BRANNMYNDIGHET»? KOMMUNESTYRET
DELEGERER NORMALT TIL:
• PLAN OG BYGGESAK
• VA-AVDELINGEN.
• BRANNVESENET
Tittel på presentasjon 3
SAMSPILL I REGULERING/BYGGESAK
• VA GIR, PÅ ET TIDLIG TIDSPUNKT I PROSESSENE, UTTALELSE/OPPLYSNINGER
OM EKSISTERENDE KAPASITETER OG PLASSERING AV EKSISTERENDE
BRANNKUMMER/HYDRANTER. BRUKER OPPLYSNINGER I KART, MODELLERING
OG ERFARING FRA DRIFT. KAN STILLE KRAV TIL ANLEGGENES FUNKSJON OG
KVALITET. VISER TIL: VA-NORM OG RETNINGSLINJER.
• ANSVARLIG PROSJEKTERENDE BRUKER OPPLYSNINGENE I VIDERE
PROSJEKTERING
• BRANNVESENET GIR PÅ FORESPØRSEL UTTALELSE TIL PLANEN.
• BYGGESAK BEHANDLER SØKNAD OG PÅSER AT KRAVENE TIL SLOKKEVANN KAN
OPPFYLLES FØR TILLATELSER GIS I BYGGE- OG DELINGSSAKER.
• VA OG BRANNV. BØR MØTE I FORHÅNDSKONFERANSER
Tittel på presentasjon 4
VANNFORSYNINGENS BIDRAG
TILGANG PÅ MYE VANN, SÆRLIG VED STORBRANNER, ER VIKTIG.
NYE BOLIG OG NÆRINGSAREALER MÅ PLANLEGGES MED:
• TILSTREKKELIG SLOKKEVANNSKAPASITET.
• SAMT SIKKER VANNFORSYNING
• HØYDE/SLOKKEVANNBASSENG
• TRYKKØKNINGSSTASJONER MED NØDAGGREGATER
• RINGLEDNINGER (2-SIDIG FORSYNING)
• DRIFTSOVERVÅKING
• VAKTORDNING/BEREDSKAP
Tittel på presentasjon 5
TILSTREKKELIG KAPASITET:
FRA TEK 10 (17)
FØLGENDE YTELSER MÅ MINST VÆRE OPPFYLT FOR VANNFORSYNING
UTENDØRS:
• BRANNKUM/HYDRANT MÅ PLASSERES INNENFOR 25-50 M FRA INNGANGEN TIL
HOVEDANGREPSVEI.
• DET MÅ VÆRE TILSTREKKELIG ANTALL BRANNKUMMER/HYDRANTER SLIK AT ALLE
DELER AV BYGGVERKET DEKKES.
• SLOKKEVANNSKAPASITETEN MÅ VÆRE:
• MINST 20 L/S I SMÅHUSBEBYGGELSE
• MINST 50 L/S, FORDELT PÅ MINST TO UTTAK, I ANNEN BEBYGGELSE
• KOMMUNEN KAN KREVE STØRRE KAPASITET.
Tittel på presentasjon 6
VANNFORSYNINGENS BIDRAG
PLANLEGGING – FORVALTNING – PROSJEKTER
DRIFT OG FORVALTNING:
• VA-DRIFT OG FORVALTNING HAR ANSVARET FOR ANLEGGENE I DETS
LEVETID. HAR BEREDSKAP OG KVALITETSKONTROLL I HENHOLD TIL
DRIKKEVANNSFORSKRIFTEN.
• HAR ANSVARET FOR SLOKKEVANNSUTTAKENE
• KOMMUNEN BØR EIE OG DRIFTE LEDNINGER TIL OG MED BRANNKUMMER
FOR Å HA KONTROLL OG GOD DRIFT PÅ DISSE.
Tittel på presentasjon 7
VANNFORSYNINGENS UTFORDRINGER
PRIORITERE NOK RESSURSER TIL DRIFT OG UTSKIFTING.
• GAMLE RØR OG VENTILER GROR DELVIS IGJEN MED BELEGG OG
RUSTKNOLLER. DÅRLIG KAPASITET.
• HMS - KUMMER KAN VÆRE FARLIGE Å GÅ NED I. DÅRLIGE FORANKRINGER
OG STIGEFESTER
• BRANNVENTILER OG STENGEVENTILER FUNGERER IKKE OPTIMALT
• REDUKSJONSVENTILER SOM DET ER LITE FORBRUK IGJENNOM KAN SETTE
SEG FAST. ÅPNER IKKE NOK VED BEHOV? JEVNLIG KONTROLL OG
VEDLIKEHOLD
• RØRBRUDSVENTILER ER PROGRAMMERT TIL Å STENGE PÅ FOR LAV
GJENNOMSTRØMNING? KONTROLLER MOT BEHOV FOR SLOKKEVANN
Tittel på presentasjon 8
VANNFORSYNINGENS UTFORDRINGER
VIKTIG AT BRANNVESENET RASKT KAN KOMME TIL SLUKKEVANNSUTTAKENE
EKSEMPLER PÅ TING SOM FORSINKER TILKOBLING AV SLANGER:
• KUMANVISERE SOM PEKER FEIL VEI ELLER ER GJEMT I VEGETASJON
• IS, ELLER SNØ OVER KUMLOKK, SNØ OG VEGETASJON KAN SKJULE HYDRANTER.
• KUMMER ER FULLE AV VANN
• DYPE KUMMER UTEN FASTMONTERT STIGE
• HMS - GASS, ELLER LITE OXYGEN I KUM
• GAMLE KUMMER SOM IKKE FUNGERER OPTIMALT, PLUNDER MED VENTILER OG
MILJØLOKK
• BRANNKUMMER/HYDRANTER ER PLASSERT FOR LANGT UNNA.
• BILER ER PARKERT OVER BRANNKUMMER
• ASFALT/GRUS I SPETTHULLENE TIL KUMLOKKENE
Tittel på presentasjon 9
VA-BIDRAG UNDER BRANNUTRYKNING
DÅRLIG TRYKK/LITE VANN ØVERST I EN TRYKKSONE, ELLER PGA
SONESTENGT VENTIL:
• VA-DRIFT HAR I NOEN OMRÅDER MULIGHETEN TIL Å LEGGE OM
VANNFORSYNINGEN, SLIK AT HØYERE TRYKK/MERE VANN LEDES TIL
BRANNSTEDET.
• VIKTIG DA MED KARTLEGGING, PLANLEGGING OG GOD DIALOG
MELLOM BRANNVESENET OG VA-AVDELINGENE
Tittel på presentasjon 10
INTERNKONTROLL
BRANNKUMMER/HYDRANTER BØR VÆRE UNDERLAGT
VEDLIKEHOLDSRUTINER
• TILSTANDSKONTROLL
• RAPPORT
• TILTAKSPLAN
• UTFØRELSE
• DOKUMENTASJON
Tittel på presentasjon 11
HYDRANT ELLER BRANNKUM?
Tittel på presentasjon
12
• I VÅRT OMRÅDE BRUKES
VANLIGVIS BRANNKUMMER.
• HYDRANT KAN/BØR KREVES
NÅR DET ER SÆRSKILT BEHOV
FOR DET.
TILKOBLING AV SLANGER:
• HYDRANT, CA. 1. MINUTT, 1
MANN
• BRANNKUM, 5 – 6 MINUTTER
UTEN PLUNDER, 2 MANN
Brannkum bør ha kumlokk med
brannvesenets logo – sparer tid
Tittel på presentasjon 13
VANN TIL AUTOMATISKE SLOKKEANLEGGKAP. 4, § 21 - VEILEDEREN
DET FREMGÅR AV VEILEDEREN AT:
• I OMRÅDER SOM REGULERES TIL VIRKSOMHET HVOR SPRINKLING ER
AKTUELT, SKAL KOMMUNEN SØRGE FOR AT DET ER TILSTREKKELIG
VANNFORSYNING TIL Å DEKKE BEHOVET.
KOMMENTAR:
• HER MÅ VANNFORSYNINGEN VURDERE SLUKKEVANNSKRAVET OPP MOT
DRIKKEVANNSKVALITET.
Tittel på presentasjon 14
TILBAKESTRØMSSIKRING VED UNDERTRYKK
• VANNLEDNINGER, SÆRLIG TIL SPRINKLERANLEGG OG HYDRANTER ,
HAR STILLESTÅENDE VANN.
• VANNET BLIR OVER TID FORURENSET OG HELSESKADELIG, DERSOM DET VED
UNDERTRYKK SUGES TILBAKE TIL HOVEDLEDNING OG VIDERE INN I
STIKKLEDNINGER TIL FORBRUK.
• TILBAKESTRØMSSIKRING
• SLIKT VANN VIL KOMME I VÆSKEKATEGORI 3. NS-EN 1717
• TILBAKESLAGSVENTIL MONTERES PÅ SPRINKLERLEDNING VED
TILKOBLINGSPUNKTET TIL HOVEDLEDNING OG DET MÅ VURDERES OGSÅ PÅ
HYRANTLEDNING.
•
Tittel på presentasjon 15
TILTAK MOT NEGATIVT TRYKK
PLANLAGT VANNFORSYNINGSKAPASITET:
• MAKS LEVERINGSMENGDE VED ET RESTTRYKK I LEDNINGSNETTET PÅ 1,0 BAR, MÅLT PÅ
DET STED I TRYKKSONEN SOM FÅR LAVEST TRYKK PÅ GRUNN AV
SLOKKEVANNSUTTAKET.
NÅR KAN DET ALLIKEVEL OPPSTÅ UNDERTRYKK?
• STORT UTTAK AV VANN, EKSEMPELVIS VED BRANNSLUKKING
FORDI: PLANLAGT VANNFORSYNINGSKAPASITET ER, SOM REGEL, TEORETISK BEREGNET. VENTILER
KAN VÆRE NESTEN STENGT.
FYSISKE TILTAK SOM REDUSERER FAREN FOR INNSUG
• VANNLEDNINGEN LEGGES HØYERE ENN AVLØSPLEDNINGER
• «MILJØLOKK» MONTERES PÅ BRANNVENTILER.
• AVLØP FRA VANNKUMMER
• REPARERE LEKKASJER MED TRYKKET PÅ, OM MULIG.
• DOBBELTVIRKENDE OG STORE NOK LUFTEVENTILER
Tittel på presentasjon 16
SLOKKEVANNSSEMINAR I BERGEN 20.4.17
• LOVER OG REGLER. FOREBYGGENDE FORSKRIFTEN. NORSK VANN RAPPORT
• NY FORSKRIFT 1.1.16 – NY VEILEDNING AUGUST 2016
• VEILEDNING TIL § 21 SLOKKEVANN ER LAGT TIL.
• MER LESBAR OG TILRETTELAGT FOR DIGITALE MEDIER
• SLOKKEMETODER. VANNBEHOV.
• NOEN METODER TRENGER MINDRE VANN
• TILGANG PÅ MYE VANN ER UANSETT VIKTIG OG PÅ HEDMARKEN BRUKES HYDRANTER
• RETNINGSLINJE FRA DRAMMENSREGIONEN
• PLAN OG BYGGESAKSBEHANDLING I BERGEN KOMMUNE
• STOR FORDEL AT DE HAR FÅTT FORANKRET I KOMMUNEPLANENS AREALDEL, AT DET I ALLE
REGULERINGSPLANER SKAL VÆRE EN VA-RAMMEPLAN, SAMT HVA DEN SKAL INNEHOLDE
• SPRINKLERANLEGG
• BRANSJEORGANISASJONEN «BTF» ØNSKER DIALOG FOR GODE RETNINGSLINJER
Tittel på presentasjon 17
Tittel på presentasjon 18
Takk for oppmerksomheten