7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
1/27
SAGEM LINK AHigh CapacityNew Agent Software
Release Notes
IDC Version: idc_swr_4.95s30SFD Version (Package): SFD_4.95s30
Feb 2008
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
2/27
New Agent Software Release Notes Ver1.3 - IDC4.952
Proprietary and Confidential
0. Table of Contents
0. Table of Contents 21. Document Control 32. Introduction 43. Supported Systems and Configurations 54. SW/HW Configurations and Compatibility 75. NSV Content 106. New Features 127. Modified Features 138. Features Not Supported 149. Limitations 1510. Corrected Bugs 1611. Open Bugs 1712. Products and Features Description 1913. Software Upgrade Procedure 23
14.
System Information 27
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
3/27
New Agent Software Release Notes Ver1.3 - IDC4.953
Proprietary and Confidential
1. Document Control
SAGEM Communications
Project: S5 release
Document Name: 1500P High Capacity New Agent Release Notes idc_swr_4.95s19nc
Publication History
Revision Date Notes
Rev 1.0 21/Dec/06 Release version
Rev 1.1 14/Feb/07 Mux FW, 3156 MRMC and RFU bug fixes
Rev 1.2 11/Mar/07 Add note for 2+2 XPIC Diversity (page 6 line 10)
Emphasizing SW requirement with new IDM HW (page 9sec 4.2)
Rev 1.3 10/Apr/07 New/old IDMs compatibility in XPIC, MIB compilation andnew IDM QPSK support bug fixes
Rev 1.4 28/Feb/08 Bug fix errors during Tx power/temperature changeswith 1500HP RFUs
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
4/27
New Agent Software Release Notes Ver1.3 - IDC4.954
Proprietary and Confidential
2. Introduction
This NSV includes new software package for the 1500P High Capacity product linethat includes 1xSTM-1/OC-3, 2xSTM-1/OC-3, 1xDS3 and 3xDS3 interfaces.
Linkpilot version 2.14 or above should be used in order to manage network elementswith software versions in this NSV.
2.1 Project Release History
The following SW releases were previously released for the high-capacityRegenerator-Access product line:
# NSV SWPackage
Date Main Features
1 IDC 4.07 Apr 2004 1500P platform introduction XPIC, HSB,Diversity
2 IDC 4.52e9 May 2005 Eth WSC, 311Mbps IDMs, 2+2 ExternalProtection
3 IDC 4.52e10 May 2005 1500P ODU 38GHz support (O5.49q)4 IDC 4.60b72 Dec 2005 1500HP RFU support, DS3 interfaces, 3128
XPIC-Diversity, IDC Eth+EOW5 IDC 4.95s19 Ver1.0
Jan 2007
1500HP 11GHz support, SFD, User Channel
6 IDC 4.95s19 Ver1.1Feb 2007
Mux FW, 3156 MRMC and RFU bug fixes
7 IDC 4.95s20 Ver1.2Apr 2007
New/old IDMs compatibility in XPIC, MIBcompilation and new IDM QPSK support bugfixes
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
5/27
New Agent Software Release Notes Ver1.3 - IDC4.955
Proprietary and Confidential
3. Supported Systems and Configurations
3.1 Supported Systems
Supported system MRMC (Multi-Rate-Multi-Constellation) configurations (determinedby modem configuration scripts):
# ModemScript
Bit Rate
[Mbps]
Channel BW(Occupied BW)
[MHz]
Modulation IDM Interface
1 1528 155 28 (26) 128QAM STM-1/OC-33xDS3*311Mbps using XPIC
2 1550 155 50/56 (45) 16QAM STM-1/OC-33xDS3
3 3156 311 56 (52) 128QAM 2x STM-1/OC-3(one IDM)*622 Mbps usingXPIC
4 3150 311 50 (45) 256QAM 2x STM-1/OC-3(one IDM)
5 1540 155 40 (30.5) 64QAM STM-1/OC-3
6 1540W* 155 40 (36) 32QAM STM-1/OC-37 4410 44 10 (9) 64QAM 1xDS38 4420 44 20 (15.5) 16QAM 1xDS39 4440* 44 40 (25) QPSK 1xDS3* New Modem script
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
6/27
New Agent Software Release Notes Ver1.3 - IDC4.956
Proprietary and Confidential
3.2 Supported Configurations
Supported and unsupported configurations of this NSV:
# Configuration Supported[Yes/No]
Notes
1 1+0 Yes2 1+1 HSB Internal Protection Yes3 1+1 Diversity (SD/FD) Internal
ProtectionYes
4 1+1 HSB External Protection Yes5 1+1 HSB with Diversity External
ProtectionNo
6 East-West Yes7 2+0 Yes8 2+0 (XPIC) Yes9 2+2 HSB (XPIC) External Protection Yes
10 2+2 Diversity (XPIC) ExternalProtection
No Only SD using 1500HPRFUs (IFC)
11 2+2 Diversity (XPIC) in 3128 system(2U chassis)
Yes Space Diversity only(no HSB or FD)
12 2xSTM-1/OC-3 IDMs 1+0, 1+1(Internal Protection), East-West, 2+0
Yes
13 2xSTM-1/OC-3 IDMs 1+1/2+2
(External Protection)
No
14 2xSTM-1/OC-3 IDMs Diversity No15 2xSTM-1/OC-3 IDMs XPIC (622Mbps
system)Yes Using two 2xSTM-
1/OC-3 IDMs16 1/3xDS3 IDMs 1+0, 1+1 (Internal
Protection), East-West, 2+0Yes
17 1/3xDS3 IDMs 1+1/2+2 (ExternalProtection)
No
18 1/3xDS3 IDMs Diversity Yes19 1/3xDS3 IDMs XPIC No20 1xDS3 IFC with 1500HP RFU No SD using IF Combining* New supported configuration
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
7/27
New Agent Software Release Notes Ver1.3 - IDC4.957
Proprietary and Confidential
4. SW/HW Configurations and Compatibility
4.1 Supported HW Configurations
The table below summarized the different hardware options this NSV supports:
# Description Marketing model SAGEM Part Number
IDC
1 IDC with 2xE1 wayside 15P-IDC-E1 06-0029-x2 IDC with 2xT1 wayside 15P-IDC-T1 06-0032-x
3 IDC with Ethernet waysidefor STM1 15P-IDC-ETH-STM1 06-0043-x
4 IDC Aux Eth for STM/DS3(2xEth wayside with EOW)
15P-IDC-ET-EOWfor STM/DS3
06-0053-x
IDM
1 IDM-155 Mbps Opticalinterface Single-Mode,1300nm, SCConnector
15P-155-SM/SC 05-0030-x
05-0056-x (for 1500HPRFU)
2 IDM-155 Mbps Opticalinterface Multi
Mode,1300nm, SCConnector
15P-155-MM/SC 05-0034-x
3 IDM-155 Mbps Electricalinterface CMI/1.0-2.3
15P-155-CMI 05-0035-x
05-0057- x (for 1500HPRFU)
4 IDM-311 Mbps Opticalinterface Single-Mode,1300nm, SCConnector
15P-311-SM/SC 05-0036-x
5 IDM-311 Mbps Optical
interface MultiMode,1300nm, SCConnector
15P-311-MM/SC 05-0037-x
6 IDM-311 Mbps Electricalinterface CMI/1.0-2.3
15P-311-CMI 05-0038-x
7 1500P IDM Single DS3 15PI-DS3 05-0045-x
05-0055-x (for 1500HPRFU)
8 1500P IDM 3*DS3 15PI-3*DS3 05-0044-x
05-0054-x (for 1500HP
RFU)
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
8/27
New Agent Software Release Notes Ver1.3 - IDC4.958
Proprietary and Confidential
4.2 IDC-IDM Compatibility
IDC compatibility with different IDM types:
# IDC IDM-155 IDM-311 IDM-1xDS3 IDM-3xDS3
1 15P-IDC-E1 Go Go No Go No Go2 15P-IDC-T1 Go Go Go Go3 15P-IDC-ETH-STM1 Go Go Go Go4 15P-IDC-ET-EOW for
STM/DS3Go Go Go Go
Note:
The compatibility refers to IDCs loaded with this NSV release
Important note!New HW IDMs (unified IF-Modem board, ROHS compliant) requires this NSV releaseloaded on the IDC.New HW IDMs are clearly marked with label on IDM front panel: "RequiresSTM1/DS3 SW i4.95s19 or above".
4.3 IDM-ODU/RFU Compatibility
IDM compatibility with different ODU types:
ODU# IDM
SL A 1500P 1500HP 1500SP
Notes
1 IDM 155 Go Go Go Go2 IDM 311 No Go* Go No Go No Go Only 28MHz
channels in 6-11GHzRFUs
3 IDM 1xDS3 Go Go Go Go4 IDM 3xDS3 Go Go Go Go
* Consult SAGEM in order to determine compatibility
Note:
The compatibility refers to IDMs connected to IDCs loaded with this NSVrelease
All IDMs do not support "I" ODUs of any kind
Operating frequency bands:
Sagem Link A ODU 6-38GHz
1500P ODU 11-38GHz
1500HO RFU 6-11GHz 1500SP 6-8GHz
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
9/27
New Agent Software Release Notes Ver1.3 - IDC4.959
Proprietary and Confidential
4.4 Software Upgrade Limitations
No limitation.This NSV can be downloaded on any of the above IDCs containing any previously-released High Capacity Regenerator-Access software package (refer to sec 13 of thisdocument for software upgrade procedure).
4.5 HW Compatibility in a Link
IDC compatibilityo IDC with 2xE1 wayside should work with IDC with 2xE1 in external protection
configuration and across the link.o IDC with 2xT1 wayside should work with IDC with 2xT1 in external protection
configuration and across the link.o IDC with 2xEth wayside should work with IDC with 2xEth or 2xEth+EOW
across the link.o The compatibility refers to IDCs loaded with this NSV release
IDM compatibilityo IDM-155 should work with IDM-155 or IDM-311 (only one STM-1/OC-3 port
active) in internal/external protection configuration and across the link.o IDM-1xDS3 should work with IDM-1xDS3 or IDM-3xDS3 (only one DS3 port
active) in internal protection configuration and across the link.
ODU/RFU compatibilityo Sagem Link A ODU should work with 1500P ODU in internal/external
protection configuration and across the link.o Sagem Link A ODU should work with 1500SP in internal/external protection
configuration and across the link (not XPIC).o Sagem Link A ODU should not work with 1500HP.o 1500SP should not work with 1500HP.o 1500SP and 1500HP can work with 1500P IDU type only (no Sagem Link
A1500/1528).
4.6 SW Compatibility in a Link
Operating a link with new SW at one end and old SW at remote end is possiblealthough SAGEM recommends upgrading SW on both ends of the link (and in theentire network).
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
10/27
New Agent Software Release Notes Ver1.3 - IDC4.9510
Proprietary and Confidential
5. NSV Content
The NSV package includes the following components:
Component Target Version Remarks
SFD Single file downloadpackage
SFD_4.95s30.sfd
IDC IDC Software Idc_swr_4.95s30nc.idnIDC Boot Soft Idc_bsf_4.96.s.idnIDC Boot Flash Idc_bot_3.66.s.idn No need to
upgrade in field
MUX MUX Firmware1xSTM-1/OC-3 IDM mux_reg20_81v10.frx2xSTM-1/OC-3 IDM mux_reg22_4.15.frx1xDS3 / 3xDS3 mux_ds3v24q6.frx1xSTM-1/OC-3 IDM mux_reg30_20v10.frx Internal card
redesign2xSTM-1/OC-3 IDM mux_reg32_4v06.frx Internal card
redesign
Modem Modem Firmware mdm_a2_3.0a.frm
Configuration Script-1528 mdm_cfg1_2.01.cfmConfiguration Script-1550 mdm_cfg2_2.01.cfmConfiguration Script-3156 mdm_cfg3_2.03.cfmConfiguration Script-3150 mdm_cfg4_2.02.cfmConfiguration Script-1540(64QAM)
mdm_cfg6_2.03.cfm
Configuration Script-1540W(32QAM)
mdm_cfg21_2.00.cfm
Configuration Script-4410 mdm_cfg7_2.04.cfmConfiguration Script-4420 mdm_cfg8_2.05.cfmConfiguration Script-4440 mdm_cfg20_2.03.cfm
MRMC Table MRMC table MRMC_tbl_0.01p.mrm For modemconfigurationoptions
IDC Wayside AUX (2xEth +EOW) wsc_10b1_6.40j.frw2xEth WSC_10b0_4.8.frw
ODU ODU Sagem Link A o3.32.odn o3.32.odu whenupgrading fromFA1500/1528IDU
ODU 1500P o552f.odn o552f.odu when
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
11/27
New Agent Software Release Notes Ver1.3 - IDC4.9511
Proprietary and Confidential
upgrading fromFA1500/1528IDU
RFU RFU 1500HP/1500SPODC Software Titanium809a4.rftRFU Firmware fpga_v7.fro
MIB Mib File FIBEAIR_5.00j.MIB
Linkpilot Linkpilot version 2.14
Software upgrade procedure is detailed further this document (refer to sec 13).
Notes regarding ODU versions: The 1500P IDUs can work with Sagem Link A1500 ODUs and 1500P ODUs.
There are different SW versions for the different ODUs.
When upgrading an ODU, file with the extension ".odu" should be selected whenthe ODU is connected to a Sagem Link A1500/1528 IDU and file with theextension ".odn" should be selected when connected to a 1500P IDU.
1500HP RFUs can be connected only to 1500P IDUs.
1500HP RFUs have ODC software and RFU firmware versions.
1500P 11GHzThe 1500P 11GHz ODU requires O5.52g SW file. This version is specifically for the11GHz ODU.As all 11GHz 1500P ODUs are shipped from the factory with O5.52g, no need forsoftware upgrade in any case.
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
12/27
New Agent Software Release Notes Ver1.3 - IDC4.9512
Proprietary and Confidential
6. New Features
The new features refer to the previous Regenerator NSV: IDC 4.60b72/73 from Dec2005.Main features are explained in details further this document (see sec 12).
# Feature Description/Notes
1 SFD Single File Download.
Simple software download process using a single filecontaining the different SW and FW versions andconfiguration scripts.
2 DIR Display of the files stored in the IDC.
3 Error counter inloopback mode
Error counter (defected blocks) was added for the IDU(IF) and ODU/RFU (RF) loopback for real-time monitoringof Rx status.
4 User Channelsupport
New IDC HW:
V.11 Asynchronous (up to 19200 baud)
RS-232 Asynchronous (up to 19200 baud).
V.11 Synchronous Co-Directional (64Kbps)
V.11 Synchronous Contra-Directional (64Kbps)5 New modem
configurations(MRMC)
1540W (155 Mbps, 32QAM)
4440 (DS3, QPSK)
6 Unified versions for1500HP and1500SP RFUs
1500HP has RFU SW and FW (FPGA)
1500SP has RFU SW only (no FW)
7 1500HP 11GHz RFU New product introduction
Important note!
With this release new IDM HW is released to comply with ROHS requirements.The RoHS directive (European Union directive 2002/95/EC) stands for the RestrictionOf the use of certain Hazardous Substances in electrical and electronicequipment. This Directive bans the placing on the EU market of new electrical andelectronic equipment containing more than agreed levels of lead, cadmium, mercury,hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenylether (PBDE) flame retardants.
The new IDM HW requires this NSV release loaded on the IDC.New HW IDMs are clearly marked with label on IDM front panel: "Requires
STM1/OC3/DS3 SW 4.95s19 or above".
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
13/27
New Agent Software Release Notes Ver1.3 - IDC4.9513
Proprietary and Confidential
7. Modified Features
# Feature Description/Notes
1 Compression of IDCfiles
For disk space
2 "Loss of Protection"alarm
[Internal Protectionconfiguration only]
"Loss of Protection" alarm is raised when one IDM ispowered off or ejected. Alarm severity = Warning. Origin= IDC. Carrier LED = Yellow.
Alarm clears when IDM is powered on or protection modeis disabled.
3 Unified Modem-IFboard
SW support for internal hardware design change(functionality not affected).
4 DC power switch New DC input power switch without a latch. Press andhold for two seconds to power on/off the IDM.
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
14/27
New Agent Software Release Notes Ver1.3 - IDC4.9514
Proprietary and Confidential
8. Features Not Supported
# Feature Description/Notes
1 Fast Ethernet (and8E1/T1), GbE, 640P,3200T
Separate NSV releases
2 MMC Multi Media Card
3 EOW for 2xE1/T1wayside IDCs
EOW is available for 2xEth wayside only
4 E1 wayside for1/3xDS3 IDMs
1/3xDS3 IDMs can work only with IDCs equipped with2xEth, 2xT1, 2xEth+EOW
5 Diversity support for2xSTM-1/OC-3 IDMs
2xSTM-1/OC-3 (311Mbps) IDMs do not support diversityconfiguration
6 XPIC support forDS3 IDMs
1/3xDS3 IDMs do not support XPIC configuration
7 1xDS3 IFC with1500HP RFU
No support for 1500HP RFU space diversity using IFC (IFCombining) when connected to 1xDS3 IDMs
8 DS3 support for "I"ODUs
1/3xDS3 IDMs do not support Sagem Link A1500/1528 "I"or 1500P "I" ODUs
9 Pre-distortion for1500P ODUs in field
1500P ODUs already sent from SAGEM do not supportand cannot be upgraded in the field for pre-distortionsupport (requires factory calibration)
10 Pre-distortion forSagem Link A ODUs
No pre-distortion support Sagem Link A1500/1528 ODUs
11 Auto detection ofneighbor IP
Manual configuration only of neighbor IP
12 SNMPv3, IPv6
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
15/27
New Agent Software Release Notes Ver1.3 - IDC4.9515
Proprietary and Confidential
9. Limitations
# Limitation Description/Notes
1 Set default configuration Hard reset required
2 1540 - 155Mbps over40MHz channels
Applicable for new IDMs sent from SAGEM only.
Upgrade of units already in the field needs to beverified with SAGEM (depends on Modem boardversion).
3 Protection configuration
changes
Wait 3 minutes after changing protection configuration
before coping configuration between IDMs ("Copy toMate" commands)
4 Frequency change ofremote ODU
Cannot change remote ODU frequency in XPIC modewith 1500P ODUs.
Workaround: change remote ODU frequency first.
5 System resets Wait 2 minutes between IDM and IDC reset in order toallow full power-up sequence
6 Longer system up timedue to disk-on-chip unzipand integrity check
Power up with 2 IDMs 2 minutes.
Power up with one IDM 2:30 minutes.
SW reset 2 minutes.
7 3128 2U - power down toan IDM will not initiate a"Mate ConfigurationMismatch" alarm
IDC SW reset is required
8 Reset push-buttondisabled
SW reset the IDC using Linkpilot or eject the IDC
9 ODU/RFU reset after
SW upgrade using SFD
The ODU/RFU upload is followed by ODU reset thatwe'll cause service disruption of ~20 seconds. Thiscannot be disabled when using the SFD.
10 1500HP - max RG223cable length 70m
Compared to 100m for 1500P/SP
11 1500HP ACCP notsupported on same OCB
Adjacent Channel Co Polarization
12 1500HP - maxbandwidth 30.5MHz
Every MRMC with Occupied BW < 30.5MHz issupported
13 1500HP IFC support For MRMCs with occupied BW between 24MHz to30.5MHz
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
16/27
New Agent Software Release Notes Ver1.3 - IDC4.9516
Proprietary and Confidential
10. Corrected Bugs
The corrected bugs refer to the previous Regenerator NSV: IDC 4.60b72/73.Items in RED are bug fixes from IDC 4.95s20 Apr 2007 release.
# Description Notes
1 Errors on Tx power changes or RFUtemperature changes with 1500HP RFUs[rare]
Wrong pre-distortion valuescorrected
2 ODU mute in XPIC configuration due to wrongidentification of IDU-ODU communication
problem.
The fix implemented is areliable polling of ODU status.
3 False signal degrade on Fiber/Radio alarmwhen PM data is cleared
4 Continuous IDC resets in 2xEth+EOW IDCsdue to floating reset signal
Implemented in Wayside FWwsc_10b1_6.39p.frw or later
5 Telnet and TFTP work only if based onstandard IP/Mask subnets.
For example: IP 192.xxx.xxx.xxx will not workwith 255.255.0.0 mask
6 [311Mbps IDMs] When disabling the wayside
channel, the EOW will be disabled7 High radio errors in 3156 MRMC script [rare] 3156 MRMC script update
- mdm_cfg3_2.03.cfm
8 STM1/STM2 line errors after multiple resets[rare]
MUX FW update
- mux_reg30_20v10.frx- mux_reg32_4v06.frx
9 False "Extreme Temperature" alarm (~-10C)in 1500HP RFUs
RFU version update
- titanium809a4.rft
10 Compatibility of old and new HW IDMs in XPICconfiguration (no cancellation of cross-
polarization signal)
IDC SW update
- idc_swr_4.95s20.idn
11 No support for QPSK script with new HW IDM IDC SW update
- idc_swr_4.95s20.idn
12 MIB compilation error (with certain compilers) MIB file update
- FIBEAIR5.00j.mib
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
17/27
New Agent Software Release Notes Ver1.3 - IDC4.9517
Proprietary and Confidential
11. Open Bugs
# Description Workaround
1 "Remote Communication" alarms (or otheralarms) due to heavy load on Ethernet NMSport. The processor drops less prioritized taskas it has to check each packet.
Never connect Ethernet trafficto NMS port. Use designatedVLANs to separatemanagement packets fromtraffic.
2 Alarm "Test#6 Failed" on power up in case ofmultiple resets under software download [rare]
Avoid multiple resets duringsoftware download. Ifencountered, reset IDU
3 1500P ODU and 1500HP versions are missingin the event log when downloaded using SFD.
Versions are downloaded andcan be verified in Linkpilot
4 IDO-ODU Communication failure due to IDChot-swap during "Copy-To-IDC" command[rare]
Avoid IDC hot-swap during"Copy-To-IDC" process, orreset the system afterwards
5 [3xDS3] "Unexpected signal" alarm on ports 1and 2 due to IDC SW reset when DS3 lineloopback is active
Reset IDM
6 [3128 XPIC-Diversity 2U] - power down to anIDM will not initiate a "Mate ConfigurationMismatch" alarm
IDC SW reset is required
7 [2+2 configuration] Active IDC software resetwill cause ~2 seconds of traffic disruption.IDC hot-swap will have the same effect, butthe traffic disruption will be permanent.
Force switch and then reset theIDC or disconnect protectioncable before IDC reset
8 IDC software reset causes a 3 seconds trafficdisruption in the left port of the waysidechannel
9 IDC reset when connecting to 1500AL (Line-to-Line ADM) when Media Specific bytes areused
10 No Tx channel number information in Linkpilot
after Set Default Configuration
11 [1/3xDS3 IDMs in 1+1 configuration] 97.5% ofprotection switches below 50mSec
12 [STM-1/OC3 Electrical in 1+1 internalconfiguration] Standby IDM reset will cause 1bit error on Active IDM [occasional]
13 [1500HP RFU] ODC software upload might failif performed during multiple protectionswitches
Repeat the upload
14 [3128 XPIC-Diversity ] Enabling ATPC fromthe Standby IDM will enable ATPC on both
local units and only the remote Active unit
Perform ATPC settings from theActive IDM
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
18/27
New Agent Software Release Notes Ver1.3 - IDC4.9518
Proprietary and Confidential
15 [1500HP RFU] Reset IDM when XPIC isenabled will cause "RFU SynthesizerUnlocked" alarm the link will be down [veryrare]
Reset IDM again
16 Telnet session will stuck if two attempts toconnect (from different PCs) at the same time
17 Disabling the STM-1/OC-3 port will disable theEth wayside channel
Enable the STM-1/OC-3 port
18 [1500HP/SP] False "Cable Open" alarm raisedwhen no SW in RFU Ignore alarm and upload SW
19 [1500HP] False RFU Power Failure" alarmwhen RFU is muted [ occasionally]
Ignore alarm if RFU is muted
20IDC insertion causes radio traffic hit [rare]
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
19/27
New Agent Software Release Notes Ver1.3 - IDC4.9519
Proprietary and Confidential
12. Products and Features Description
12.1 SFD Single File Download
The purpose of the SFD is to provide a simple and easy software download process.It allows download of single file instead of several SW/FW files.
The different SW, FW and configuration scripts that has to be download upon newrelease are zipped into one file named "SFD_xxx.idn (where xxx=IDC SW versionname).Events of each file downloaded are displayed in the alarm log.The ODU/RFU will be uploaded automatically upon download of SFD file and defaultwill be an upload to both ODUs/RFUs.The ODU/RFU upload is followed by ODU reset that we'll cause service disruption of~20 seconds. This cannot be disabled when using the SFD.
For upgrade purposes, this feature can be used with IDCs containing 4.52e10 versionor later.
Software download process:
Download IDC software version
SW reset IDC
Download SFD file
Wait until all files are downloaded and uploaded (IDU andODU/RFU)
HW reset the IDU
Verify all correct files are updated in Linkpilot.
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
20/27
New Agent Software Release Notes Ver1.3 - IDC4.9520
Proprietary and Confidential
12.2 User Channel Support
Asynchronous and synchronous channels are supported in this NSV: oneasynchronous per carrier (radio) or one synchronous on Channel#1 (radio right).
The following UCs are supported (maimum 64Kbps over the radio):
V.11 Asynchronous (up to 9600 baud)
RS-232 Asynchronous (up to 9600 baud)
V.11 Synchronous Co-Directional (64Kbps)
V.11 Synchronous Contra-Directional (64Kbps)
.Available modes of operations are:
Two V.11 Asynchronous UCs (one per radio)
Two RS-232 Asynchronous UCs (one per radio)
One RS-232 Asynchronous UC, and one V.11 Asynchronous UC(one per radio)
One V.11 Synchronous Co-Directional or one V.11 SynchronousContra Directional UC (mapped to CH#1)
The connector dedicated for the UC is shared with the SLIP.
The system powers up with SLIP and UC disabled, and the user can choose betweenthe two.
Auxiliary channels screen of Linkpilot:
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
21/27
New Agent Software Release Notes Ver1.3 - IDC4.9521
Proprietary and Confidential
UC connector pinout:
Pin Serial PPPAsynchronousUC RS-232
AsynchronousUC V.11
SynchronousUC V.11
I/O
1
DCDData
CarrierDetected
(N.C)UC1_TxD
UC_TxCLK-Transmitted
clockOut
2RxD
ReceivedData
UC1_TxDTransmitted
DataUC1_TxD +
UC_TxCLK+Transmitted
clockOut
3TxD
Transmitted
Data
UC1_RxDReceived
DataUC1_RxD +
UC_RxCLK+Received
clock
In/
Out
*
4
DTRData
TerminalReady
(N.C)UC1_RxD -
UC_RxCLK-Received
clock
In/Out
*
5SG
SignalGround
SGSignal
Ground
SG
SignalGround
SGSignal
GroundCom
6DSR
Data SetReady
(N.C)UC2_TxD
.
UC_TxD Out
7RTS
Request ToSend
UC2_RxDReceived
DataUC2_RxD + UC_RxD + In
8CTS
Clear ToSend
UC2_TxDTransmitted
DataUC2_TxD + UC_TxD + Out
9RI RingIndicator
(N.C)(N.C)
UC2_RxD - UC_RxD -In
* Output in contra-directional mode
UC connectivity can be achieved using the standard terminal cable (DB-9).
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
22/27
New Agent Software Release Notes Ver1.3 - IDC4.9522
Proprietary and Confidential
12.3 DIR Disk Files
Display of the files stored in the IDC."Read-Only" display for information allows the user to see what SW/FW files arestored and when downloaded.
The "Sub type", "Firmware" and "Properties" are internal EPROM fields.
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
23/27
New Agent Software Release Notes Ver1.3 - IDC4.9523
Proprietary and Confidential
13. Software Upgrade Procedure
13.1 Introduction
The following section details the recommended software upgrade steps for this NSVrelease.
In SAGEMs 1500P IDU, the IDC card (In Door Controller) stores the software,firmware and configuration scripts to the different components in the IDU and ODU.Whenever IDU/ODU initializes, the versions are loaded from the IDC. Once loaded,the IDMs/ODU can work without IDC.
SAGEM releases complete software packages. When upgrading a unit, all theSW/FW components must be upgraded to assure proper operation.There are different software release packages for different products lines (HighCapacity, Fast Ethernet, GbE).
13.2 Preliminary Steps
1. Record the Existing Software Versions
1.1 Launch Linkpilot.
1.2 Record the current software versions in File System InformationVersions or check them using the Configuration Report.
1.3 Contact SAGEM support in order to verify that the software upgrade ispossible for your current configuration.
2. Configure Linkpilot - TFTP Parameters
TFTP (Trivial File Transfer Protocol) is used for software download. Its parametersshould be configured using the Linkpilot configuration application.
2.1 Close any open session of Linkpilot.2.2 Create new folder in drive C named dwld (C:\dwld) and store all download
files in it.2.3 Start Programs Linkpilot Linkpilot Configuration. The Linkpilot
Configuration screen will be opened.
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
24/27
New Agent Software Release Notes Ver1.3 - IDC4.9524
Proprietary and Confidential
2.4 Select File Transfer Configuration tab.
2.5 In TFTP Server Address field enter the IP address of the PC.2.6 In TFTP Files Location field browse and enter the folder path where the
download files are located (C:\dwld).2.7 Leave default settings in TFTP Timeout and TFTP Retries (90 seconds, 4
respectively).2.8 In Use Internal TFTP Server field select True.2.9 Click Apply to save changes and Close Linkpilot Configuration application.
13.3 Files Download using Linkpilot
3.1 Launch Linkpilot.3.2 File Software Download. The Software Download screen will appear.
3.3 Verify the File Location and the TFTP Server IP Address are displayedcorrectly.
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
25/27
New Agent Software Release Notes Ver1.3 - IDC4.9525
Proprietary and Confidential
By clicking Select you will be able to browse for the different software versions of thedifferent components. Only the files stored in the File Location with thecorresponding file extension will be available for selection. Clicking Apply will start thedownload. Download status will be displayed in the Download Log.
3.4 Download the IDC software version file (idc_swr_xxx.idn).
In certain cases or in case software download fails, clearing the configuration from thedisk might be required. Clear_Config_Disk can be performed using the terminal: (3)Maintenance (1) IDC (5) Clear Disk Configuration.
3.5 Perform IDC SW reset using Linkpilot: Maintenance Software Reset IDC.
3.6 Download all remaining files, including IDC boot files, MUX FWs, Modem FW,Modem configuration scripts, Wayside FW, ODC and MRMC table (multipleselection is possible).
3.7 Once download completed successfully, reset IDU by powering off the IDMs orusing Linkpilot: Maintenance Hardware Reset IDC.
3.8 Verify new software files were updated correctly in the Linkpilot.
Important note!Typically, ODU/RFU software is not required for customer's application.Please download ODU/RFU files ONLY when actually needed after consulting withSAGEM customer support.Downloading 1500HP RFU SW and FW might take up to 25 minutes. Do not interruptor cancel the download once started.
Do not download O5.52f version to 1500P 11GHz ODU (requires O5.52gversion).
13.4 Single File Download using Linkpilot
Single File Download (SFD) provides a simple and easy software download process.It allows download of single file instead of several SW/FW files.
For upgrade purposes, this feature can be used with IDCs containing 4.52e10 version
or later.
4.1 Launch Linkpilot.4.2 File Software Download. The Software Download screen will appear.
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
26/27
New Agent Software Release Notes Ver1.3 - IDC4.9526
Proprietary and Confidential
4.3 Verify the File Location and the TFTP Server IP Address are displayedcorrectly.
4.4 Download the IDC software version file (idc_swr_xxx.idn).4.5 Perform IDC SW reset using Linkpilot: Maintenance Software Reset
IDC.4.6 Download the SFD file (SFD_xxx.sfd).4.7 Once download completed successfully, reset IDU by powering off the IDMs or
using Linkpilot: Maintenance Hardware Reset IDC.
4.8 Verify new software files were updated correctly in the Linkpilot.
7/28/2019 SL a Reg-Access SW Release Notes - Ver1.3 IDC4
27/27
Proprietary and Confidential
14. System Information
The following section provides relevant information for users regarding systemprocedures, configurations and accessories.
14.1 Cables and Accessories
14.1.1 Cables for Ethernet Wayside Connections
Cables/splitters are used for dual wayside operation and for external protectionconfiguration.
RJ-45 Ethernet cable (straight) connecting 1xEth Wayside port tohub/switch in 1+0/1+1 configuration (in 1+1 configuration the Wayside isallocated to the active IDM). Standard cable can be used.
RJ-45 Ethernet cable (crossover) connecting 1xEth Wayside portsbetween them or to a PC. Standard cable can be used.
2-port splitter for 2xEth Wayside ports (8 pin to 2x4 pin splitter).SAGEM marketing model 15P-IDC-ET_CBLSAGEM part number WA-0140-x (x latest revision)
M
F
WA-0140-x
4
4
8
Fch1
ch2
IDU
Protection splitter for external protection of Wayside ports (8 pin to 2x8 pinsplitter).SAGEM marketing model TBD
SAGEM part number WA-0188-x (x latest revision)
F
WA-0140-x
4
4
8
F
FM
M
WA-0188-x
8
8
M
IDU
8
IDU