SKIDCATALOG

ECONTECHLLC.COM I 716.389.2279

Page 2: SKID CATALOG - ECON Technologiesecontechllc.com/.../02/ECT_Skid-Catalog_v15-PRINT.pdf · SKID CATALOG ECONTECHLLC.COM I 716.389.2279. At Energy Conversion Technologies (ECON), we

At Energy Conversion Technologies (ECON), we take pride in our ability to provide solutions meeting any hot water need. Our primary focus is to ensure all occupants are guaranteed the heat they demand and deserve. Our engineering team selects the right-sized hardware for each job to be integrated and installed effectively. Pre-fabricated skid packages and advanced control systems allow ECON Technologies to provide reliable systems that meet every demand, every time. In addition, ECON offers distribution pumping packages and heat exchanger packages that are engineered for each system’s specific requirements.

ECON’s engineered modular skid packages offer a fully assembled, high-efficiency, pre-piped and pre-wired customized boiler package designed to fit through a standard doorway. These packages offer a simplified installation, virtually eliminating any shut-down time and reducing the risk to the customer. With boilers ranging from 850-6,000MBH input each and packages offered in multiple modules, ECON has a solution available to meet any customers needs.

CUSTOM SOLUTIONS TOMEET ANY NEED

MODULAR BOILER SKIDS

OPTIMIZING SOLUTIONS FOR MECHANICAL SYSTEMS

Page 3: SKID CATALOG - ECON Technologiesecontechllc.com/.../02/ECT_Skid-Catalog_v15-PRINT.pdf · SKID CATALOG ECONTECHLLC.COM I 716.389.2279. At Energy Conversion Technologies (ECON), we

Customized solutions are created by ECON engineers to adapt proven skid standards and meet any specific requirement based on site constraints

Reduced footprint frees up valuable mechanical room space

Optimally-sized equipment maximizes performance and minimizes energy consumption

ECON fully engineers and specifies all components in the heating plant including but not limited to pumps, heat exchangers, boiler venting, air separators, storage tanks and expansion tanks.

A comprehensive system is constructed prior to shipment, leaving only the fuel, water, and power to be connected on site

Fits through a standard 36” wide door

Flanged water connections, quick power, and control wiring

Intuitive designs that assemble together at the steel base defeat the installation“learning curve”

Provides redundancy to minimize or eliminate downtime in the event of failure

Seamless future expansion

Allows for optimization of mechanical room layout

Minimizes future replacement costs by removing rigging constraints

Designed to immediately meet any foreseen load at any time

Organized layout allows for simple service access

Electric and pressure-tested at factory

Real-time monitoring analyzes performance and anticipates potential failures, thereby limiting downtime and maintaining peak efficiency

Experience shows a utility savings of 25-45% through industry leading equipment coupled together with engineering expertise

ENGINEERED DESIGN

INSTALLATION EFFICIENCY

MODULAR CONSTRUCTION

TRUSTED SYSTEM PERFORMANCE

SKID BENEFITS & SAVINGS

ECONTECHLLC.COM I 716.389.2279

A DIVERSE BODYOF WORKECON’s applications and installs reach into markets such as education, hospitality, entertainment, industrial and commercial. Our engineering team enables us to customize and adapt our packages to meet any need.

EDUCATIONK-12, Universities, Colleges

HOSPITALITYHotels, resorts, nursing homes, hospitals, medical , multi-family

ENTERTAINMENTSporting Arenas, Stadiums, Theaters, Convention Centers

INDUSTRIALProcess, Manufacturing, Food, Automotive

COMMERCIALRetail centers, Markets, Grocery, Warehouse

Page 4: SKID CATALOG - ECON Technologiesecontechllc.com/.../02/ECT_Skid-Catalog_v15-PRINT.pdf · SKID CATALOG ECONTECHLLC.COM I 716.389.2279. At Energy Conversion Technologies (ECON), we

RATINGS AND DATABOILER DATA EB-850 EB-1000 EB-1500 EB-2000 EB-2500 EB-3000 EB-3500 EB-4000 EB-4500 EB-5000 EB-6000Input BTUH/Boiler 850,000 1,000,000 1,500,000 1,999,000 2,500,000 3,000,000 3,499,000 3,998,000 4,500,000 5,000,000 6,000,000 Output BTUH/Boiler 811,750 955,000 1,426,500 1,901,049 2,397,500 2,904,000 3,327,549 3,802,098 4,329,000 4,795,000 5,808,000 Standard Voltage 120V/1Ph 230V/1Ph 230V-3Ph Fuel Natural Gas MAWP (psi) 160 Min/Max Flow (gpm) 16.2/81.2 19.1/95.5 28.5/142.7 38/190.2 48/239.8 58.1/290.5 66.6/332.9 76.1/380.4 86.6/433.1 95.9/479.7 116.2/581Boiler FLA (amps) 9.5 12.7 10.3 10.3 20.6 Boiler HP 24.3 28.5 42.6 56.8 71.6 86.8 99.4 113.6 129.3 143.2 173.55Water Volume (gal) 42 42 40 62 58 56 102 124 96 116 112Min./Max. Gas Pressure (w.c.) 3/14

TEMP & PRESSURE DATA Max Flow Rate (gpm) @ 20°ΔT 81.2 95.5 142.7 190.2 239.8 290.5 332.9 380.4 433.1 479.7 581Pressure Drop (ft-hd) 2.0 2.8 3.2 4.8 6.6 5.6 4.6 4.8 9.0 9.6 12.2Flow Rate (gpm) @ 30°ΔT 60.9 71.7 107.1 142.7 179.9 217.9 249.7 269.4 324.8 359.8 435.8Pressure Drop (ft-hd) 1.3 1.8 2.4 3.6 5.0 4.2 3.5 3.4 6.8 7.2 9.2Flow Rate (gpm) @ 40°ΔT 40.6 47.8 71.4 95.1 119.9 145.3 166.4 158.3 216.5 239.8 290.5Pressure Drop (ft-hd) 0.5 0.7 1.6 2.4 3.3 2.8 2.3 2 4.5 4.8 6.1

TRIM Number of Relief Valves 1 2 Relief Valve Pressure Rating (PSI) 50 (standard) Inlet Water Connection (in) 3 4 Outlet Water Connection (in) 3 4 Gas Connection (in) 1 1-1/2 2-1/2 Flue/Combustion Air Connection (in) 5/6 5/6 6/8 8/8 10/10 12/12

SKID ELECTRICAL Skid FLA (amps) 14.6 N/ASkid FLA (amps) N/A 16.3 N/ASkid FLA (amps) N/A 12.4 16.5 31 36.1Skid FLA (amps) N/A 6.1 8 15 17.3

SKID ASSEMBLED DIMENSIONS Height (in) 80 Width (in) 32 34 Length (in) 132.8 132.8 144.4 181.4

CLEARANCES Front (in) 36 Rear (in) 36 Right (in) 24 Left (in) 24 Top (in) 36

WEIGHTS Shipping - Boiler Skid (lb) 1305 1375 1555 1880 1955 2055 3420 3745 3600 3920 4150Shipping - Piping Skid (lb) 1138 1138 1156 1156 1317 1317 1549 1549 1619 1619 1619Operating - Both Skids (lb) 3193 3263 3591 3639 3795 3951 6412 6484 6590 6697 6894

Page 5: SKID CATALOG - ECON Technologiesecontechllc.com/.../02/ECT_Skid-Catalog_v15-PRINT.pdf · SKID CATALOG ECONTECHLLC.COM I 716.389.2279. At Energy Conversion Technologies (ECON), we

1,2 – Product FamilyEB – ECON Boiler Skid

3,4 – Capacity Per Boiler08 – 850 MBH 35 – 3500 MBH10 – 1000 MBH 40 – 4000 MBH15 – 1500 MBH 45 – 4500 MBH20 – 2000 MBH 50 – 5000 MBH25 – 2500 MBH 60 – 6000 MBH30 – 3000 MBH

5 – Skid QuantityA -1 D – 4 B – 2 E – 5 C – 3 F – 6 *Consult ECON for QTY > 6

6 – FuelG – Natural Gas

7 – Piping ConfigurationP – Primary OnlyS – Primary/Secondary

9 – Relief ValveH – 30 N - 100 J – 50 P – 125 K – 60 Q – 150 M – 75 R – 160

9, 10 – VoltageE1 – 208V / 1PHE2 – 208V / 3PHE3 – 230V / 1PHE4 – 230V / 3PHE5 – 460V / 3PH

11 – Factory Packaged ControlsS – Stand AloneT – Integrate with existing BMS (Modbus or Bacnet)

12 – GraphicsW – Standard PackageX – Customer Specified Graphics

13 – ConfigurationY –Master Boiler on LeftZ – Master Boiler on Right

BOILER DATA EB-850 EB-1000 EB-1500 EB-2000 EB-2500 EB-3000 EB-3500 EB-4000 EB-4500 EB-5000 EB-6000Input BTUH/Boiler 850,000 1,000,000 1,500,000 1,999,000 2,500,000 3,000,000 3,499,000 3,998,000 4,500,000 5,000,000 6,000,000 Output BTUH/Boiler 811,750 955,000 1,426,500 1,901,049 2,397,500 2,904,000 3,327,549 3,802,098 4,329,000 4,795,000 5,808,000 Standard Voltage 120V/1Ph 230V/1Ph 230V-3Ph Fuel Natural Gas MAWP (psi) 160 Min/Max Flow (gpm) 16.2/81.2 19.1/95.5 28.5/142.7 38/190.2 48/239.8 58.1/290.5 66.6/332.9 76.1/380.4 86.6/433.1 95.9/479.7 116.2/581Boiler FLA (amps) 9.5 12.7 10.3 10.3 20.6 Boiler HP 24.3 28.5 42.6 56.8 71.6 86.8 99.4 113.6 129.3 143.2 173.55Water Volume (gal) 42 42 40 62 58 56 102 124 96 116 112Min./Max. Gas Pressure (w.c.) 3/14

TEMP & PRESSURE DATA Max Flow Rate (gpm) @ 20°ΔT 81.2 95.5 142.7 190.2 239.8 290.5 332.9 380.4 433.1 479.7 581Pressure Drop (ft-hd) 2.0 2.8 3.2 4.8 6.6 5.6 4.6 4.8 9.0 9.6 12.2Flow Rate (gpm) @ 30°ΔT 60.9 71.7 107.1 142.7 179.9 217.9 249.7 269.4 324.8 359.8 435.8Pressure Drop (ft-hd) 1.3 1.8 2.4 3.6 5.0 4.2 3.5 3.4 6.8 7.2 9.2Flow Rate (gpm) @ 40°ΔT 40.6 47.8 71.4 95.1 119.9 145.3 166.4 158.3 216.5 239.8 290.5Pressure Drop (ft-hd) 0.5 0.7 1.6 2.4 3.3 2.8 2.3 2 4.5 4.8 6.1

TRIM Number of Relief Valves 1 2 Relief Valve Pressure Rating (PSI) 50 (standard) Inlet Water Connection (in) 3 4 Outlet Water Connection (in) 3 4 Gas Connection (in) 1 1-1/2 2-1/2 Flue/Combustion Air Connection (in) 5/6 5/6 6/8 8/8 10/10 12/12

SKID ELECTRICAL Skid FLA (amps) 14.6 N/ASkid FLA (amps) N/A 16.3 N/ASkid FLA (amps) N/A 12.4 16.5 31 36.1Skid FLA (amps) N/A 6.1 8 15 17.3

SKID ASSEMBLED DIMENSIONS Height (in) 80 Width (in) 32 34 Length (in) 132.8 132.8 144.4 181.4

CLEARANCES Front (in) 36 Rear (in) 36 Right (in) 24 Left (in) 24 Top (in) 36

WEIGHTS Shipping - Boiler Skid (lb) 1305 1375 1555 1880 1955 2055 3420 3745 3600 3920 4150Shipping - Piping Skid (lb) 1138 1138 1156 1156 1317 1317 1549 1549 1619 1619 1619Operating - Both Skids (lb) 3193 3263 3591 3639 3795 3951 6412 6484 6590 6697 6894

MODEL NUMBER

Page 6: SKID CATALOG - ECON Technologiesecontechllc.com/.../02/ECT_Skid-Catalog_v15-PRINT.pdf · SKID CATALOG ECONTECHLLC.COM I 716.389.2279. At Energy Conversion Technologies (ECON), we

1500-3000 MBH BOILER SKIDS

3500-6000 MBH BOILER SKIDS

OPTIMIZING SOLUTIONS FOR MECHANICAL SYSTEMS

Page 7: SKID CATALOG - ECON Technologiesecontechllc.com/.../02/ECT_Skid-Catalog_v15-PRINT.pdf · SKID CATALOG ECONTECHLLC.COM I 716.389.2279. At Energy Conversion Technologies (ECON), we

Bridging the gap between boiler management and building control systems by integrating our skids with industry proven software and intuitive graphics.

THEBOTTOMLINEWE’RERAISINGYOURS

LOWER FIRST COSTOCCUPANTSATISFACTION & LOYALTY

REDUCED UTILITIESREDUCED RISK

INCREASEDREVENUE

Comprehensive mechanical skid packages require minimal installation drastically reducing labor time and material sourcing.

Fewer service interruptions and precise controllability produce

comfortable occupants.

Efficient equipment and programmed operation parameters minimize fuel, electrical, and water consumption, resulting in paybacks as quick as 3 years.

Highly reliable, industry respected equipment coupled

with N+1 designs and advanced control systems ultimately reduce costs associated with emergency service and system inoperability.

INTEGRATED CONTROLS

ECONTECHLLC.COM I 716.389.2279

Page 8: SKID CATALOG - ECON Technologiesecontechllc.com/.../02/ECT_Skid-Catalog_v15-PRINT.pdf · SKID CATALOG ECONTECHLLC.COM I 716.389.2279. At Energy Conversion Technologies (ECON), we

Corporate Headquarters95 Stark StreetTonawanda, NY 14150p: [email protected]

ENERGY CONVERSION TECHNOLOGIESPRE-FABRICATED SKIDDED PACKAGES

Designing a skidded system creates dependable, single source responsibility while minimizing installation time and expense. Our design team can customize any skid to meet individual project requirements, confirming that the system is fully optimized for each site’s unique conditions. Please contact our sales team to help you custom design your skidded package today.

SAVE TIME AND MONEY WITH ECON TECHNOLOGIES

TOTAL CUSTOMER SATISFACTION

ECONTECHLLC.COM