13
SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

Embed Size (px)

Citation preview

Page 1: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP power

Automation and Drives

SITOP modularThe First Modular Power Supply

SITOP - a step ahead

Page 2: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 2

SITOP power

Automation and Drives

The First Modular Power Supply

Page 3: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 3

SITOP power

Automation and Drives

Basic Units

Portfolio:

1-/2-phase 24V/ 5A and 10A 1-phase 24V/ 20A and 40A 3-phase 24V/ 20A and 40A 3-phase 48V/ 20A

Extremely robust Metal housing and reliable DIN

rail mounting with metal clip

Minimum space requirements

Reduced installation efforts Primary and secondary

terminals are on the same level Potentiometer for voltage

adjustment is integrated in front of the unit

IMPORTANT: no additional mounting width needed !!

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Page 4: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 4

SITOP power

Automation and Drives

Basic Units

Wide input voltage range

Adjustable output voltage up to + 20%

Adjustable reaction to short circuits Shutoff with storage or automatic restart

U/I-characteristic curve with power boost to supply up to 300% of the rated output current

Switch-selectable for parallel operation

Easy understandable display of operating status with 3 LEDs Green: output voltage > 20V

In case of failure when used in parallel operation there is no LED signal from the broken device!

Yellow: output voltage < 20VSignalizes overload in operating mode „automatic restart“

Red: shutoff with storage or remote shutoff In order to avoid confusion there is only one LED signal at the same

time !

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Page 5: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 5

SITOP power

Automation and Drives

Basic Units 5A and 10A

Wide input range ! One power supply for worldwide

single phase and 3-phase operations Wide input voltage range of 85...132V/

176...550V AC Voltage selector on the right side of

the unit Single phase (hot wire and ground)- or

two phase mode possible (2 x hot wires)

Compact design Width

70mm at 24V/5A, 90mm at 24V/10A

Long hold up time when used with three phase networks

E.g. >100ms at 400V, >200ms at 500V

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Page 6: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 6

SITOP power

Automation and Drives

193 Countries – ONE power supply

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Page 7: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 7

SITOP power

Automation and Drives

Basic Unit 20A and 40A

Single phase mode withselectable input voltage range

120/230V ACrated input voltage

85...132V/176...264V ACvoltage range

AC 120 V can be selected byusing a jumper

3-phase mode withwide input voltage range

400/440/480V 3AC rated voltage 320 ... 550V 3AC voltage range

Minimum space requirements Compared to SITOP Standard Line:

20% less space, 40% fewer footprints

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Page 8: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 8

SITOP power

Automation and Drives

Basic Unit 48V/ 20A

Input voltage

400/440/480V 3AC rated voltage 320...550V 3AC voltage range

Same design as three phase unit 24V/40A

Power Boost Function Up to 60A

Buffer module is not connectable, all other SITOP modular features are available:

Selectable short circuit characteristics Constant current characteristic or storing

shutdown

Adjustable output voltage up to 56V Parallel connection possible

Signalling module can be snapped on

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Page 9: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 9

SITOP power

Automation and Drives

Signalling Module

Can be directly connected on the left side of the basic unit

Signalling contacts foroptimal integration into the control system

Output voltage 24V okay Operating readiness okay

Remote switch on/ switch offof basic unit

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Page 10: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 10

SITOP power

Automation and Drives

Add on module for DINrail mounting

For brief power failures up to3 seconds

800 msec at 5A load current 100 msec at 40A load current Can be used in parallel connection

to increase hold up time needs

The buffer module supplies the precise output voltage to which the basic unit is set with a tolerance of minus 1V.

In case of temporary increased power demands the module supplies up to 40A in addition to thepower boost of 60A with the 20A &120A with the 40A power supply)

Buffer Module

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Page 11: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 11

SITOP power

Automation and Drives

The First Power Supply in Modular Design

Signallingmodule

Basic unit 20A Buffer module

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Page 12: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 12

SITOP power

Automation and Drives

SITOP - A Standard with Facets

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

Addons

ACthree-phase

ACsingle-phase

AC/DC

1-/2-ph. 5A+10A flat design3.5A

10A in IP65,industry

LOGO!Power24V/ 1.3 + 2.5A 5V/ 3 + 6.3A12V/ 1.9 + 4.5A15V/ 1.8 + 4A

DC-UPS modules 15A+40A

Battery modules 2.5/3.2/7/12Ah

0.5A

0.375A

Signalling module

Basis unit 20A + 40A

Buffer module

blue writing: voltages different from 24V

Diagnosis moduleSITOP select

2-phase 600V industry, 24V/20A 40A book-form

1-/2-phase Basic unit 5A + 10A

flexi 3 - 52V dual 15V

DC 2A, AC/DC 2.5A + 4A 10A 7A, AS-i DC; 2.4A, AS-i, IP65

1-phase Basic unit 20A + 40A

Basis unit 48V/20A

2A

Monitoring

SITOP modular

Signalling Bridging power outages

Page 13: SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead

SITOP - a step ahead A&D SE PS 2002/12/02 13

SITOP power

Automation and Drives

InternetHomepage and Microsites

Basic units

Signalling module

Buffer module

Design

Benefits

Overview

Internet

www.siemens.com/sitop

www.a-step-ahead.de