WARRANTY

The Anritsu product(s) listed on the title page is (are) warranted against defects in materi-als and workmanship for one year from the date of shipment.

Anritsu’s obligation covers repairing or replacing products which prove to be defectiveduring the warranty period. Buyers shall prepay transportation charges for equipment re-

turned to Anritsu for warranty repairs. Obligation is limited to the original purchaser.Anritsu is not liable for consequential damages.

LIMITATION OF WARRANTY

The foregoing warranty does not apply to Anritsu connectors that have failed due to nor-

mal wear. Also, the warranty does not apply to defects resulting from improper or inade-quate maintenance by the Buyer, unauthorized modification or misuse, or operation

outside the environmental specifications of the product. No other warranty is expressed orimplied, and the remedies provided herein are the Buyer’s sole and exclusive remedies.

TRADEMARK ACKNOWLEDGEMENTS

MS-DOS, Windows, and Windows for Workgroups are registered trademarks

of the Microsoft Corporation.

Site Master and  Cable Mate are trademarks of Anritsu Company.

NOTICE

Anritsu Company has prepared this manual for use by Anritsu Company personnel andcustomers as a guide for the proper installation, operation, and maintenance of Anritsu

Company equipment and computer programs. The drawings, specifications, and informa-tion contained herein are the property of Anritsu Company, and any unauthorized use or

disclosure of these drawings, specifications, and information is prohibited; they shall notbe reproduced, copied, or used in whole or in part as the basis for manufacture or sale ofthe equipment or software programs without the prior written consent of Anritsu Com-

pany.

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 3/49

Index

How To Use This Manual   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Programming Manual Organization  . . . . . . . . . . . . . . . . . . . . 1

Programming Overview

G enera l Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Ca bling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Seria l Communication P ar am eters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Communications Er ror Checking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

P ar am eter Valida tion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

En tering Remote Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Exit ing R emote Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

L if et im e of Ch a n g e s t o S i t e Ma st e r Op era t in g Pa ra m e t ers . . . . . . . . . . 3

Write Cycle Limitat ion of EE P ROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Functional Description

Init ia l izeEnt er remote mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Ent er remote mode immediately . . . . . . . . . . . . . . . . . . . . . . . . 4

ConfigureS yst e m

Fixed CW mode control . . . . . . . . . . . . . . . . . . . . . . . . 4

LCD backlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Wat ch dog t imer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Seria l port echo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Single sweep. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

P rinter ty pe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Tra ce Mat h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Automat ically sa ve runtime setup. . . . . . . . . . . . . . . . 4

Measurement

Measurement m ode select . . . . . . . . . . . . . . . . . . . . . . 5

Measurement unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Ca libration on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

P ower Monitor

G et P ower levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5P ow er Monitor U nits of measure . . . . . . . . . . . . . . . . . 5

Relative Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Offset Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Zero Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Frequency

St ar t frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

St op frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Da ta points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Ma rch 2000 10580-00035

C opy r igh t 1999, An rit su C o. Revision : C

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 4/49

D ist a n ce

St ar t dista nce. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

St op dista nce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Relative propaga tion velocity . . . . . . . . . . . . . . . . . . . 5

Ca ble loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

DTF Windowin g . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

DisplayDisplay mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Scale sta rt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Scale stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

M a rk e rs

On/Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Delta St at us On/Off . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Limits

On/Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

B eep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Ut il i t yTime set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Da te set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Reference number set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

ActionTrigger sweep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Sa ve system setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Recall syst em setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Sa ve sweep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Query tra ce na mes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Delete sweep tra ce. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

D a t aRecall sw eep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Ca libr a t io nCa librate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Configure Spectru m Ana lyzerSet F requency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Set C enter Frequency a nd S pan . . . . . . . . . . . . . . . . . . . . . . . . . 7Set S cale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Set Ma rkers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Set Limit s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Measure OCC B W %of Power . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Measure OCC B W dB Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Set Ma x Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Set Resolution B W Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . 7

ii S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 5/49

Set Video BW Frequ ency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Set S weep Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Set Ma rker to P eak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Set Ma rker to Center. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Configure Cust om Ca ble Ta bleWrit e to Ta ble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Read from Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

S t a t u sQuery system st at us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Self-test Trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Read fa ilure counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Clear failure counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

CloseExit r emote mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Control Byte Descriptions

Control byte summa ry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

C on t r ol b y t e 1 S e tu p s y st em . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

C on t r ol b y t e 2 S e t S i t e M a s t er f req u en cy . . . . . . . . . . . . . . . . 12

C on t r ol b y t e 3 S e lect mea s u r em en t m od e . . . . . . . . . . . . . . . . 13

C on t r ol b y t e 4 S e t S i t e M a s t er s ca l e . . . . . . . . . . . . . . . . . . . . 13

C on t r ol b y t e 5 S e t S i t e M a s t er m a r k er . . . . . . . . . . . . . . . . . . 14

C on t r ol b y t e 6 S e t S i t e M a s t er l im it . . . . . . . . . . . . . . . . . . . . . 15

C on t r ol b y t e 7 S e t D TF pa r a m e t er s . . . . . . . . . . . . . . . . . . . . . 15

C on t r ol b y t e 8 S e t t i m e/d a t e . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

C on t r ol b y t e 9 S e t r ef er en ce n u mb er . . . . . . . . . . . . . . . . . . . . 17

Co n t rol b yt e 1 0 S e ria l p ort e ch o on /of f . . . . . . . . . . . . . . . . . . . . 1 7

C on t r ol b y t e 11 S i n g le s w e ep m od e on /of f . . . . . . . . . . . . . . . . . 17

Co n t rol b yt e 1 2 Wa t ch d og t im e r on /of f . . . . . . . . . . . . . . . . . . . 1 8

C on t r ol b y t e 13 S e q uen ce S i t e M a s t er ca l ib ra t i on . . . . . . . . . . 18

C on t r ol b y t e 14 S e t S i t e M a s t er da t a poi nt s . . . . . . . . . . . . . . . 19

C on t r ol b y t e 16 S t o r e s w e ep t r a c e . . . . . . . . . . . . . . . . . . . . . . . 19

C on t r ol b y t e 17 R eca l l s w e ep t r a c e . . . . . . . . . . . . . . . . . . . . . . . 19

C on t r ol b y t e 18 S a v e s y s t em se t up . . . . . . . . . . . . . . . . . . . . . . . 24

C on t r ol b y t e 19 R eca l l s y s t em se t up . . . . . . . . . . . . . . . . . . . . . 24

C on t r ol b y t e 20 Q uer y s y st em st a t u s . . . . . . . . . . . . . . . . . . . . . 24

Co n t rol b yt e 2 1 Trig g er sel f -t e st . . . . . . . . . . . . . . . . . . . . . . . . . 2 8C on t r ol b y t e 22 R ea d f a il cou n t er s . . . . . . . . . . . . . . . . . . . . . . . 29

C on t r ol b y t e 23 C l ea r f a il cou n t er s . . . . . . . . . . . . . . . . . . . . . . . 29

C on t r ol b y t e 24 Q u er y t r a ce n a m e s . . . . . . . . . . . . . . . . . . . . . . . 29

C on t r ol b y t e 25 D e le t e s w e ep t r a c e . . . . . . . . . . . . . . . . . . . . . . . 30

C on t r ol b y t e 30 S e le ct pr i n t er t y pe . . . . . . . . . . . . . . . . . . . . . . . 30

C on t r ol b y t e 31 S e le ct D TF w i n dow i n g . . . . . . . . . . . . . . . . . . . . 30

C on t r ol b y t e 32 S e t t r a c e m a t h . . . . . . . . . . . . . . . . . . . . . . . . . . 31

C on t r ol b y t e 39 Q u er y pow e r le ve l . . . . . . . . . . . . . . . . . . . . . . . 31

C on t r ol b y t e 40 S e t p ow e r m on i t or u ni t . . . . . . . . . . . . . . . . . . . 32

S113B, S114B, S331B, S332B PM iii

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 6/49

Co n t rol b yt e 4 1 Re la t ive m o de on /of f . . . . . . . . . . . . . . . . . . . . . . 3 2

Co n t rol b yt e 4 2 Of fse t m od e on /of f . . . . . . . . . . . . . . . . . . . . . . . 3 2

Co n t rol b yt e 4 3 Z ero m o de on /of f . . . . . . . . . . . . . . . . . . . . . . . . . 3 3

C on t r ol b y t e 48 Tr i gg er s w ee p . . . . . . . . . . . . . . . . . . . . . . . . . . 33

C on t r ol b y t e 50 C h e ck b a t t e r y s t a t u s . . . . . . . . . . . . . . . . . . . . . 33

C on t r ol b y t e 64 Au t om a t i ca l l y s a v e r u n t im e s et u p . . . . . . . . . . 34

C on t r ol b y t e 69 E n t e r r e mot e m od e . . . . . . . . . . . . . . . . . . . . . . 34C on t r ol b y t e 70 E n t e r r e mot e m od e i m m ed i a t el y . . . . . . . . . . . . 34

C on t r ol b y t e 80 Wr i t e cu s t om ca b l e . . . . . . . . . . . . . . . . . . . . . . . 35

C on t r ol b y t e 81 R eca l l cu s t om ca b l e . . . . . . . . . . . . . . . . . . . . . . 35

C on t r ol b y t e 96 M ea s u r e O C C B W % of P o w e r . . . . . . . . . . . . . . 36

C on t r ol b y t e 97 M ea s u re O C C B W d B D ow n . . . . . . . . . . . . . . . 36

C on t r ol b y t e 99 S e t S p ect r u m An a l y z er F r e q uen cy . . . . . . . . . . 36

Co n t rol b yt e 1 00 S e t S p ect ru m An a lyz e r Ce n t e r F re q/S p a n . . . . 3 7

C on t r ol b y t e 101 S e t S p ect r u m An a l y z er S ca l e . . . . . . . . . . . . . . 37

C on t r ol b y t e 102 S e t S p ect r u m An a l y z er Ma r k e r . . . . . . . . . . . . 38

Co n t rol b yt e 1 03 S e t S pe ct ru m An a lyz e r L im it . . . . . . . . . . . . . . 3 8

C on t r ol b y t e 105 S e t S p ect r u m An a l y z er Ma x H ol d . . . . . . . . . . . 39

Co n t rol b yt e 1 06 S e t S p ect ru m An a lyz e r Re solu t ion B W F re q . . 3 9

Co n t rol b yt e 1 07 S e t S p ect ru m An a lyz e r Vid eo B W F re q . . . . . . 3 9C on t r ol b y t e 108 S e t S p ect r u m An a l y z er S w ee p M od e . . . . . . . . 40

C on t r ol b y t e 109 S e t S p ect r u m An a l y z er M a r k er t o P ea k . . . . . . 40

C on t r ol b y t e 110 S e t S p ect r u m An a l y z er M a r k er t o C e n t er . . . . 40

C on t r ol b y t e 255 E x i t r e mot e m od e . . . . . . . . . . . . . . . . . . . . . . . 41

P ar am eter definit ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

iv S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 7/49

How to Use this Manual

If you wa nt t o find out

g en e r a l c o n c ep t s    for programming t he Site Mast er,

go to the P rogramm ing Overview.

If you wa nt t o find out

h ow t o   p e r f o r m a t a s k  ,

go to th e Fun ctiona l D escription.

If you wa nt t o find out

w h a t t h e   sy n t a x o f a c o n t r o l b y t e   i s,

go to the C ontrol Byt e Description.

Programming Manual Organization

Programming Overview

This section conta ins general informa tion about programming t he Site Ma ster. I t is a n intr oduction and

helps you get st ar ted.

Functional Descriptions

This section includes a complete list of ta sks you can cont rol via t he seria l port . These ar e high level descrip-

tions. Ea ch ta sk refers you to the a ppropriate individual control byte for deta ils.

Control Byte Descriptions

This section contains detailed explanations for each of the control bytes.

S113B, S114B, S331B, S332B PM 1

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 8/49

Programming Overview

This programm ing ma nua l is w rit ten exclusively for th e Anritsu Site Ma ster Models S113B , S114B, S 331B,

an d S 332B w ith firmw ar e Version 1.42 and above. For informa tion on firmw ar e upgrade, please contact y our

loca l Anritsu service cent er.

General Description

The Site Master must first be set into “remote” mode for communication with a computer. Remote mode dif-

fers from normal repetit ive sw eep a nd single-sw eep modes. During r emote mode, the S ite Ma ster suspends

normal opera tions and a t t ends to the serial port . The front pa nel display indicat es when the S ite Mast er is

in remote mode.

Once in remote mode, you can send control bytes a nd a ssociat ed dat a to the Site Ma ster via the serial port .

These control byte sequences command the Site Master to perform various functions and activities. The se-

rial port supports virtually all features accessible from the keypad. The only exception is the printer, which

requires connection t o the sa me 9 pin connector on t he Site Mast er rea r pa nel.

To complete t he commu nicat ion session, send t he contr ol byte to exit remote mode. Sit e Mas ter r esumes nor-

mal operations. You may also exit the remote mode by using the escape key.

Cabling

Serial communicat ions t ake place via t he 9 pin connector on t he back of the Site Ma ster. The Site Ma ster is a

DTE-type serial device and therefore requires a “null modem” cable for communication with a computer,

wh ich is also a DTE device. We provide a suita ble cable w ith y our Site Ma ster.

Serial Communication ParametersThe Site Ma ster communicat es at a baud r at e of 9600. It uses no par ity bits, 8 da ta bits, an d 1 stop bit

(N-8-1). No hardware handshaking is used.

Communications Error Checking

Since there is no ha rdw ar e han dsha king, byte level error ha ndling must be done by the controlling program.

The expected n umber of response byt es for each control byt e (listed in th e cont rol byte d escription section of

this ma nua l) works w ell for responses coming from the Site Ma ster. For da ta strea ms going to the Site Ma s-

ter, the “wa tch dog t imer” protects a gainst interrupted tra nsmissions by a borting a control byte sequence if

the inter-byte time limit is exceeded.

Parameter Validation

The Site Ma ster va lidates input pa ra meters for each control byte sequence. I f the input pa ra meters a re out

of range or invalid, t he Site Ma ster notifies t he computer by sending P ar am eter Er ror B yte #224 (E0h). The

Site Mast er discar ds the received dat a a nd w ait s for the next contr ol byte.

2 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 9/49

Entering Remote Mode

Send t he Ent er Remote Mode byte #69 (45h) to the Site Ma ster t o enter r emote mode at the end of a sweep.

Send t he En ter R emote Mode Immediat ely byte #70 (46h) to enter remote mode in t he middle of a sweep.

The Site Ma ster’s serial port buffer is one byte w ide. No interna l buffer exists, so wa it ing is essential. I f the

Site Ma ster is n ot in remote, sending a second byte overw rites th e original byt e comma nding it to go into re-

mote. I f you send contr ol byte #69, you must w ait until t he end of the sw eep. If you send control byte #70, th e

unit w ill enter remote mode as it r eceives the byte. Note tha t t his means t he dat a st ored for th e current

sweep may be incomplete.

Once you receive the response string from Site Master, you’re in remote mode.

Exiting Remote Mode

Send t he Exit Remote control byte #255 (FFh) to the S ite Mast er. Sit e Mast er sends a response byte of

255 (FF h) then exits r emote mode.

Lifetime of Changes to Site Master Operating Parameters

Syst em para meters changed during r emote mode remain changed for normal opera tion. They a re not aut o-

ma tically w rit ten t o the non-volat ile EEP ROM. Turning off power erases t he changed sett ings.

If you wa nt t he changes saved, you must save th e cha nge to one of the setup memories. U se either t he

run-time setup (location 0, which holds the power-on defaults) or one of the ten saved setups. See control

byt e #18 (12h) for deta ils.

Write Cycle Limitation of EE PROM

The EE P ROM, used to store setups, ha s a guar an teed lifet ime of at least 100,000 wr ite cycles and a n unlim-

ited nu mber of read cycles. The w rit e cycle limita tion is for a specific loca tion. For exa mple, you ca n st oresetup #1 100,000 times an d set up #2 100,000 times, etc.

I t is f or t h is re a son w e d o n ot a u t o m a t ica l ly s t o re t h e ch a n g e d syst e m p a ra m e t ers t o E E P ROM . I n st e a d , we

provide a mea ns of cha nging the opera ting par am eters independent of this limita t ion.

Be aware of the EEPROM write cycle limitat ion when programming the Site Master. Keep the number of

wr ite cycles to a minimum.

S113B, S114B, S331B, S332B PM 3

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 10/49

Functional Description

INITIALIZE

Enter remotemode - see control byte #69 (45h)

Site Ma ster m ust be in remote mode for further contr ol byte comma nd sequences to be accepted.

Remember t o wa it unt il Site Ma ster responds before issuing further control byte sequences.

Enter remotemode immediately - see control byte #70 (46h)

CON F I G URE S YS T E M

Fixed CW mode control - see control byte #1 (01h)

Site Ma ster “dith ers” the C W signal for improved immunit y t o interfering signa ls. Turning on th e

fixed C W signal bit “cleans up” t he output spectrum by disa bling the dithering. The dra w back isdecreased immunit y to interfering signals.

LCD backlight -see control byte #1 (01h)

LCD backlight helps in a dverse lighting condit ions.

Watch dog timer  - see contr ol byt e #12 (0Ch)

Use d t o g u a rd a g a in st in t e rru p t ed d a t a t ra n sf ers t o t h e S i t e M a st e r .

Serial port echo - see contr ol byt e #10 (0Ah)

U se this to synchronize the S ite Mast er sw eep and computer requests for current tr ace dat a . This

feature is especially useful for synchronizing dist an ce to fault sw eeps.Site Master goes into single sweep mode. It sends the sweep complete byte #192 (C0h) after the com-

pletion of each sweep. You must send the sweep trigger byte #48(30h) for the Site Master to perform

another sweep. Retrieve the trace data using control byte #17 (11h).

Single sweep - see cont rol by te #11 (0B h)

This puts t he Site Ma ster int o single sweep mode. Normally t he Site Ma ster sw eeps continua lly.

Once in the single sweep mode, send the sw eep tr igger byte #48 (30h) to cause S ite Ma ster t o per-

form a nother sw eep.

Printer type - see control byt e #30 (1Eh)

P rinter t ype is selecta ble.Trace Math - see control byte #32 (20h)

Automatically Save Runtime Setup - see contr ol byt e #64 (40h)

4 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 11/49

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 12/49

DTF Windowing - see control byte #31 (1Fh)

Allows selection of a w indow t o lessen t he side lobes.

C O N F I G U R E D I S P L AY

Display mode - see control byte #3 (03h)

Selecta ble among S WR, retur n loss, cable insertion loss, tra nsmission loss, tr an smission ga in, pow er

monitor, and spectrum an alyzer.

Scale start - see control byte #4 (04h)

Scale stop - see control byte #4 (04h)

C O N F I G U R E M AR K E R S

Marker (on/off) - see control byte #5 (05h)

Marker Delta Status (on/off) - see control byte #5 (05h)

Marker value - see control byte #5 (05h)

CON F I G URE L I M I T S

Limit (on/off) - see control byte #6 (06h)

Limit beep (on/off) - see control byte #6 (06h)

Limit value - see control byte #6 (06h)

UTILITY

ASC II t ext strings, w hich are stored w ith each sw eep, help identify t he stored tra ces. U se these control bytes

to modify t he strings before storing the t ra ce.

Timeset - see control byte #8 (08h)

Date set - see control byte #8 (08h)

Reference number set - see control byte #9 (09h)

ACTION

Trigger sweep - see contr ol byt e #48 (30h)

B oth serial port echo and single sw eep modes use this byt e to trigger a Site Ma ster sw eep. If the Sit e

Mast er is not in one of th ose modes, this byt e is ignored.

Save system setup - see control byte #18 (12h)

6 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 13/49

Recall system setup - see control byte #19 (13h)

Save sweep - see contr ol byt e #16 (10h)

Query tracenames - see control byte #24 (18h)

Delete sweep trace - see contr ol byt e #25 (19h)

D ATA

Recall sweep - see contr ol byt e #17 (11h)

U se this control byte to obta in stored tra ces or the current measurement da ta from the Site Mast er.

All tra ces an d modes use the same tra ce dat a forma t.

CALIBRATION

Calibrate - see control byte #13 (0Dh)

Comput er sequ encing of the open-short -load ca libra tion is possible.

CON F I G URE S P E CTRUM AN ALYZE R

Set Frequency - see contr ol byt e #99 (63h)

Set Center Frequency and Span - see contr ol byt e #100 (64h)

Set Scale - see contr ol byt e #101 (65h)

Set Markers - see contr ol byt e #102 (66h)

Set Limits - see contr ol byt e #103 (67h)

Measure OCC BW %of Power  - see contr ol byt e #96 (60h)

Measure OCC BW dB Down - see control byte #99 (63h)

Set Max Hold - see contr ol byt e #105 (69h)

Set Resolution BW Frequency - see cont rol by te #106 (6Ah)

Set Video BW Frequency - see control byte #107 (6Bh)

Set Sweep Mode - see control byte #108 (6Ch)

Set Marker to Peak  - see control byte #109 (6Dh)

Set Marker to Center - see control byte #110 (6Eh)

S113B, S114B, S331B, S332B PM 7

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 14/49

CON F I G URE CU S TOM CAB L E TAB L E

Write to Table - see contr ol byt e #80 (50h)

Read from Table - see contr ol byt e #81 (51h)

S TATU S

Query system status - see contr ol byt e #20 (14h)

The system status contains virtually all information about the current Site Master system state. I t is

a powerful a nd complete “sna pshot” of the sy stem.

Some control bytes a ffect multiple system para meters (such as dist an ce to fault pa ra meters). U se the

response from this control byte for preserving any of the system para meters you wish to remain un -

changed.

Self-test Trigger - see contr ol byt e #21 (15h)

Upon receiving this control byte the Site Master runs self-test. After completion of the self-test, theSite Mast er sends the results via t he serial port .

Read failure counters -see contr ol byt e #22 (16h)

In order to provide absolute confidence a bout the va lidity of a measurement, interna l counters

monitor the analog integrator and phase lock loops for error conditions. If an error occurs, it is

logged. These counters perform th e sam e function a s th e icons on th e front panel.

Clear failure counters - see contr ol byt e #23 (17h)

U se this control byte to reset t he failure counters.

C L O S E

Exit remote mode - see control byt e #255 (FF h)

Ends communication with the Site Master. “Exit ing remote mode” returns the Site Master to normal

operation.

8 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 15/49

Control Byte Summary

S113B, S114B, S331B, S332B PM 9

Control

Byte #

  Name Description

Watch-

dog

Timer

1 (01h)   Setup system System status flags and switches Yes

2 (02h)   Set frequency Sets Site Master frequency range Yes

3 (03h)   Select measurement mode Measurement domain and measurement mode Yes

4 (04h)   Set scale Sets Site Master scale values Yes

5 (05h)   Set marker Set position and on/off status of a Site Master marker Yes

6 (06h)   Set limit Set position and on/off status of a Site Master limit line Yes

7 (07h)   Set DTF parameters Sets Distance to Fault parameters Yes

8 (08h)   Set time/date Sets Time and date for a sweep trace Yes

9 (09h)   Set reference number Sets reference number for a sweep trace Yes

10 (0Ah)   Serial port echo On/Off Allows synchronization of the Site Master and request from computer

for sweep trace

Yes

11 (0Bh)   Single sweep On/Off Enable or disable the single sweep mode Yes

12 (0Ch)   Watch-dog timer On/Off Enable or disable the watch-dog timer —-

13 (0Dh)   Sequence Site Master

calibration

Trigger a calibration step Yes

14 (0Eh)   Set Site Master data points Sets number of measurement data points for Site Master mode Yes

16 (10h)   Store sweep trace Save current trace data to EEPROM Yes

17 (11h)   Recall sweep trace Site Master sends sweep data Yes

18 (12h)   Save system setup Save system setup parameters to EEPROM Yes

19 (13h)   Recall system setup Recall system setup parameters from EEPROM Yes

20 (14h)   Query system status Get the current system settings —-

21 (15h)   Trigger self-test Trigger a self test —-

22 (16h)   Read fail counters Same as icons on front panel —-

23 (17h)   Clear fail counters Reset the fail counters —-

24 (18h)   Query trace names Returns list of all saved traces —-

25 (19h)   Delete sweep trace Delete single or all stored sweep traces Yes

30 (1Eh)   Select printer type Select printer type Yes

31 (1Fh)   Select DTF Windowing Select DTF Windowing Methods Yes

32 (20h)   Set Trace Math Select Trace Math operation —-

Control Byt e Summa ry (1 of 3)

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 16/49

10 S113B, S114B, S331B, S332B PM

Control

Byte #  Name Description

Watch-

dog

Timer

39 (27h)   Query Power Level Return Power Level at Detector Port —-

40 (28h)   Set Power Unit Set Power Monitor displaying unit Yes

41 (29h)   Set Relative Mode Enable or disable Power Monitor Relative Mode Yes

42 (2Ah)   Set Offset Mode Set/Reset Power Level offset Yes

43 (2Bh)   Set Zero Mode Set/Reset Power Level zeroing mode Yes

48 (30h)   Trigger sweep Starts the next sweep —-

50 (32h)   Check Battery Status Return smart battery status —-

64 (40h)   Auto Save Runtime Setup Automatically save the runtime setup when exiting remote mode —-

69 (45h)   Enter remote mode Enters remote mode at the end of the sweep and returns model numberand firmware version

 —-

70 (46h)   Enter remote mode

immediately

Enters remote mode immediately and returns model number and firm-

ware version

 —-

80 (50h)   Write Custom Cable Input Custom Cable data to Site Master —-

81 (51h)   Recall Custom Cable Recall Custom Cable data from Site Master —-

96 (60h)   Measure OCC BW % of

Power

Measure OCC BW with % of Power method Yes

97 (61h)   Measure OCC BW dB

Down

Measure OCC BW with dB down method Yes

99 (63h)   Set Spectrum Analyzer

Frequency

Sets the Spectrum Analyzer frequency range Yes

100 (64h)   Set Spectrum Analyzer

Center Freq./Span

Sets the Spectrum Analyzer center frequency and frequency span Yes

101 (65h)   Set Spectrum Analyzer

Scale

Sets the Spectrum Analyzer scale value Yes

102 (66h)   Set Spectrum Analyzer

Marker

Set position and on/off status of a Spectrum Analyzer marker Yes

103 (67h)   Set Spectrum Analyzer

Limit

Set position and on/off status of Spectrum Analyzer limit line Yes

105 (69h)   Set Spectrum Analyzer

Max Hold

Enable or disable the Spectrum Analyzer Max Hold Yes

106 (6Ah)   Set Spectrum Analyzer

Resolution Bandwidth Freq

Sets the Spectrum Analyzer resolution BW frequency Yes

107 (6Bh)   Set Spectrum Analyzer

Video Bandwidth Freq

Sets the Spectrum Analyzer video BW frequency Yes

Control Byt e Summa ry (2 of 3)

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 17/49

S113B, S114B, S331B, S332B PM 11

Control

Byte #  Name Description

Watch-

dog

Timer

108 (6Ch)   Set Spectrum Analyzer

Sweep Mode

Sets the Spectrum Analyzer sweep mode Yes

109 (6Dh)   Set Spectrum Analyzer

Marker to Peak

Sets specified marker to peak value of the sweep Yes

110 (6Eh)   Set Spectrum Analyzer

Marker to Center

Sets the center frequency equal to the frequency of the specified

marker

Yes

255 (FFh)   Exit remote mode End serial communications —-

Control By te Sum ma ry (3 of 3)

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 18/49

Control Byte Descriptions

Setup system - Control byte #1 (01h)

D e sc r i p t i o n :    Sets syst em stat us flags a nd sw itches. The Site Master a cts on the entire byte. You must a c-count for t he sta te of each of the bits. For example, if you wa nted to turn the LC D ba cklight on wit hout dis-

turbing t he other sw itches you w ould do the following: query the S ite Mast er w ith control byte #20. You

wo u ld m a sk in t h e L CD st a t u s wit h t h e d a t a f rom re sp on se b yt e #4 1 a n d se n d t h is t o t h e S i t e Ma st e r a f t e r

cont rol byt e #1.

See control byte #20 (14h) response byte 159 for current Site Master configuration. It is important to set the

Metric/En glish fla g to the proper value before sending dis ta nce informa tion.

B y t es t o F o l l o w :    1 byte

1 ) S t a t u s b yt e ( bi t d a t a )

(LS B ) bit 0 : Fixed CW mode On/Off

bit 1 : Currently Unusedbit 2 : LCD B a ck Light On/Off

bit 3 : Measu rement U nit Metr ic/En glish (0 = E nglish, 1 = Met ric)

bit 4 : Ca l On/Off

bit 5-7 : Curr ently U nused

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte224 (E0h) P ar am eter Error : Inva lid Print er Selection or unsuccessful at t empt to

turn calibration on.

238 (EE h) Time-out E rror

Notes: Ca l can be turned on ONLY if a complete calibrat ion ha s been performed a t t he current st ar t a nd

stop frequ encies.

B it Value: 0 = Off

1 = On

Set Site Master frequency - Control byte #2 (02h)

D e sc r i p t i o n :    Sets the Site Master frequency range.

See cont rol byte #20 (14h) response byt es 4-11 for curr ent S ite Ma ster configura tion.

B y t es t o F o l l o w :    8 bytes1) St ar t F requency (highest byte)

2) Start Frequency

3) Start Frequency

4) St ar t F requency (lowest byte)

5) Stop Frequency (highest byte)

6) St op Frequency

7) St op Frequency

8) Stop Frequency (lowest byte)

12 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 19/49

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte224 (E0h) Parameter Error : Invalid frequency range

238 (EE h) Time-out E rror

Notes: St ar t a nd stop frequencies a re given in terms of 1 Hz steps.

(e.g. 100.3 MHz would be sent as 100030000 = 1,000,300,000 Hz)

Select Measurement mode - Control Byte #3 (03h)

D e sc r i p t i o n :    Sets mea surement domain an d display gra ph type. You must have a va lid calibra tion (current

frequencies and calibrat ion frequencies being the sa me) to sw itch to the D ista nce doma in.

See cont rol byte #20 (14h) response byt e 1 (01h) for curr ent S ite Ma ster doma in.

B y t e s t o F o llow: 1 byt e

1) Measurement Mode

00h = RL Fr equency

01h = SWR Frequency02h = Ca ble Loss Frequency

10h = RL Distance

11h = SWR Dista nce

20h = Tra nsmis sion Mode

30h = Spectrum Analyzer Mode

40h = Power Monitor Mode

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte224 (E0h) P ar am eter Error : Inva lid doma in or gra ph type or combinat ion

238 (EE h) Time-out E rror

Set Site Master scale - Control byte #4 (04h)

D e sc r i p t i o n :    S e t s t h e S i t e M a st e r g ra p h b ou n d a rie s.

The scale sett ings require knowing t he gra ph ty pe for proper configura tion. For example, the scale sta rt in

return loss is t he top of the gr aph w hile scale st ar t is the bottom of the gra ph for SWR. Think of the scale

st a rt a s b ein g t h e sm a llest va lu e on t h e g ra p h .

See cont rol byte #20 (14h) response byt es 12 to 19 for curr ent S ite Ma ster scaling.

B y t es t o F o l l o w :    8 bytes

1) S cale Top (high est byt e)

2) S ca le Top

3) S ca le Top

4) S cale Top (lowest byt e)

5) Scale Bottom (highest byte)

6) Scale B ottom

7) Scale B ottom

8) Scale Bottom (lowest byte)

S113B, S114B, S331B, S332B PM 13

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 20/49

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte2 24 (E 0 h ) P a ra m e t er E rro r : I n va l id sca le ra n g e

238 (EE h) Time-out E rror

Notes:

Return Loss &

Ca ble Loss:

Scaling is in   thousandths of a dB

Maximum value sent is 54000 which represents 54.00 dBMinimum value sent is 0 which represent 0.00 dB

Scale St ar t Value is the t op of the graph

Scale S top Value is the bottom of the gra ph

SWR:   Scaling is in   thousandths (of ra tio)

Maximum value sent is 65535 which represents 65.53

Minimum value sent is 1000 which represents 1.00

Scale St ar t Value is the bottom of the graph

Scale S top Value is the t op of the gra ph

G ain /Ins ertion

Loss:

Scaling is in   hundredths (of dB )

Maximum value sent is 22000 which represents –120.0 dB

Minimum value sent is 0 which represents 100.0 dB

Scale St ar t Value is the bottom of the graph

Scale S top Value is the t op of the gra ph

Set Site Master marker - Control byte #5 (05h)

D e sc r i p t i o n :    S e t s a n in d ivid ua l S i t e M a st e r m a rk er.

The Sit e Mast er sets the posit ion of a ma rker by its r elat ive posit ion on t he gra ph. The lowest posit ion is 0 at

th e sta rt frequency (or dista nce). The high est position is 129 at the s top frequency (or d ista nce). The On/Off

St at us of a Mar ker can be toggled using this contr ol byte.

In order to set frequency mar kers, you must be in the frequency domain. Likewise, if you w an t t o set dis-

ta nce markers, you must be in the dista nce doma in. Mar ker posit ion is independently remembered for dis-

tance and frequency domains.

See control byt e #20 (14h) response by tes 20 t o 27 for current frequency ma rkers. See control byt e #20 (14h)

response bytes 40 to 47 for current dista nce ma rkers. See control byt e #20 (14h) response by te 40 (28h) for

current ma rker on/off sta tus.

B y t es t o F o l l o w :    5 bytes:

1) Mar ker Number (01h = ma rker 1, 02h = ma rker 2, 03h = ma rker 3, 04h = ma rker 4)

2) Ma rker Lin e On/~ Off (01h = On, 00h = Off)

3) Ma rker D elta On/~ Off (01h = On, 00h = Off)

4) Ma rker Va lue (higher byt e)

5) Ma rker Value (lower by te)

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte224 (E0h) P ar am eter Error : Invalid ma rker, mar ker stat us, or ma rker posit ion

238 (EEh) Time-out Error

Note:   Delta Ma rker stat us is not valid for Marker 1.

14 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 21/49

Set Site Master limit - Control byte #6 (06h)

D e sc r i p t i o n :    Sets t he posit ion a nd On/Off Sta tus of the Site Ma ster Limit Line.

Curr ently, Site Ma ster supports one limit line so the limit number is a lwa ys 1. I f the limit beep is tur ned on,

the S ite Mast er beeps an y t ime the tr ace is a bove the limit line on the display. You can use return lossgra phs to “cat ch” a ba d ma tch. SWR gra ph limit beeps only when the ma tch gets good.

See control byte #20 (14h) response byte 155 for current Site Master configuration.

B y t es t o F o l l o w :    7 bytes:

1) Limit Num ber (for unit s w ith m ultiple limits, 1 for S ite Mast er)

2) Limit Line On/~ Off (01h = On, 00h = Off)

3) B eep at L imit O n/~ Off (01h = On, 00h = Off)

4) Limit Va lue (highest byt e)

5) Limit Va lue

6) Limit Va lue

7) Limit Va lue (lowest byt e)

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte224 (E0h) P ar am eter Error : Invalid limit , limit sta tus, or limit value

238 (EE h) Time-out E rror

Notes: Li mit Value depends on the current display mode selected.

Return Loss &

Ca ble Loss:

Limit is in   thousandths of a dB

Maximum value sent is 54000 which represents 54.00 dB

Minimum va lue sent is 0 w hich represents 0.0 dB

SWR:   Limit is in   thousandths (of ra tio)

Maximum value sent is 65530 which represents 65.53

Minimum value sent is 1000 which represents 1.00

G a in/Ins ertion

Loss:

Limit is in  hundredths (of dB )

Maximum value sent is 22000 which represents –120.0 dB

Minimum value sent is 0 which represents 100.0 dB

Set DTF parameters - Control byte #7 (07h)

D e sc r i p t i o n :    S e t s D ist a n ce t o F a u lt p a ra m e t ers.

B e aw ar e using this contr ol byte. The distan ce to fault pa ra meters a re all inter-related. Consequently, the

control byte must change all of those par am eters at the sa me t ime to properly set t hem.P lease refer t o the Site Ma ster opera tions ma nua l for a detailed explana tion of the fa ctors influencing proper

selection of DTF parameters.

See cont rol byte #20 (14h) response byt es 32 to 39 an d 48 to 55 for curr ent S ite Ma ster configur a tion.

B y t es t o F o l l o w :    16 bytes:

1) St ar t D ista nce (highest byte)

2 ) S t a rt D ist a n ce

S113B, S114B, S331B, S332B PM 15

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 22/49

3 ) S t a rt D ist a n ce

4) St ar t D ista nce (lowest byte)

5) St op Dista nce (highest byt e)

6) St op Distan ce

7) St op Distan ce

8) St op Dista nce (lowest byte)

9) Relative Propagation Velocity (highest byte)10) Relative P ropaga tion Velocity

11) Relat ive P ropaga tion Velocity

12) Relative Propagation Velocity (lowest byte)

13) Cable Loss (highest byte)

14) Ca ble Loss

15) Ca ble Loss

16) Cable L oss (lowest byt e)

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte224 (E0h) P ar am eter Error : Pa ra meter(s) out of ra nge

238 (EE h) Time-out E rror

Notes:   Start & Stop Distances a re in   hundred-thousandths of meter or foot (12.34 m w ould be sent a s1234000)

Relative Propagation Velocity is in   hundred-thousandths (a Relative Propagation Velocity of

0.850 will be sent a s 85000)

Cable Loss is in   hundred-thousandths of dB /m or dB /ft (-0.345 dB /m w ould b e sen t a s 34500)

Set time/date - Control Byte #8 (08h)

D e sc r i p t i o n :    Sets the real-time clock.

The curr ent Time/Da te is sta mped int o a ll st ored sw eeps (for users’ reference).

B y t es t o F o l l o w :    7 bytes

1) Hour

2) Minut e

3) Month

4 ) D a y

5) Year (Higher Byte)

6) Year (Lower B yt e)

7) Da ylight Sa vings (ON/~ OFF)

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte238 (EEh) Time-out Error

16 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 23/49

Set reference number - Control Byte #9 (09h)

D e sc r i p t i o n :    St ores a Reference Number wit h t he sweep tra ce. You determine the format .

Current reference number is found in trace 0 response bytes 32 to 54.

B y t es t o F o l l o w :    16 bytes (ASC II t ext string)

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte238 (EE h) Time-out E rror

Serial port echo On/Off - Control Byte #10 (0Ah)

D e sc r i p t i o n :    Set s t he seria l port echo mode On/Off.

Serial P ort Echo Mode uses the   single sweep mode (see contr ol byt e #11 (0B h)). Ther efore, at th e end of

each sw eep cycle, the Site Mast er sends a Sw eep Complete B yte #192 (C0h) to the serial port .This mode activat es once the Site Ma ster exits from th e remote mode. Serial P ort Echo sta tus can’t be sa ved

to or recalled from sa ved setups. Cycling power resets th e Serial port echo status to Off.

The Serial P ort Echo Mode allows run-time ha ndsha king between the Sit e Master a nd computer by doing

the following ...

1) En ter remote mode. Set Serial P ort E cho Mode On. E xit remote mode.

2) The Site Ma ster sw eeps once an d th en sends the S weep Complete By te.

3) After you receive it, ent er remote m ode. Recall s w eep 0 (la st sw eep tra ce in RAM).

4) Exit remote mode. Send S w eep Triggering B yt e #48 (30h) and w a it for th e next sw eep cycle.

5) Repeat steps 2-4.

B y t es t o F o l l o w :    1 byte

1 ) S e ria l P ort E ch o S t a t u s

00h = Off

01h = On

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte224 (E0h) P ar am eter Error : Invalid serial port echo sta tus

238 (EE h) Time-out E rror

Single sweep mode On/Off - Control Byte #11(0Bh)

D e sc r i p t i o n :    Ena bles or disables the Single Sweep Mode.

Single Sw eep Mode activa tes once the S ite Mast er exits from the remote mode.

When the S ite Mast er returns t o local mode, the S ite Mast er stops sweeping, waits for either the

Run/Hold Key of the Site Master keypad or  triggering byte #48 (30h).

Site Master also checks for remote control byte #69 (45h) at the end of each sweep. If present in the buffer,

Site Master returns to remote mode (no sweeping, locked keypad).

S113B, S114B, S331B, S332B PM 17

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 24/49

B y t es t o F o l l o w :    1 byte

1) Single Sw eep Mode St at us

00h = Off

01h = On

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte

224 (E0h) P ar am eter Error : Invalid single sweep mode stat us238 (EE h) Time-out E rror

Watch-dog timer On/Off - Control Byte #12 (0Ch)

D e sc r i p t i o n :    Enables or Disables the Watch-dog timer.

The Site Master incorporates a Watch-dog Timer for higher reliability in serial communication. In selected

contr ol bytes (see contr ol byte summa ry), the Sit e Mast er checks for the t ime interval between each byt e re-

ceived from the computer. If the time interval exceeds the set time limit (0.5 sec), the Site Master notifies the

computer by sending Time-out Byte #238 (EEh). The Site Master discards the data it just received and then

wa its for the next contr ol byte sequence.

B y t es t o F o l l o w :    1 byte

1) Wa t ch-dog ti mer On /Off

0 = Of f

1 = On

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte224 (E0h) Parameter Error : Invalid watch-dog t imer status

Sequence Site Master calibration - Control byte #13 (0Dh)

D e sc r i p t i o n :    Init iates a calibration step.

The Site Mast er must be calibrat ed to give accura te measur ements. Ca libration is based on frequency range.

Once the frequency r an ge is set , sequence the calibrat ion process using th is control byte. Measur e each com-

ponent (OP EN, SH ORT, LOAD) then t rigger th e calculat e step. The calculate st ep uses the m easurements

obta ined and genera tes th e correction fa ctors.

U pon receiving this control byte any old calibrat ion da ta is lost . The Site Ma ster does the calibrat ion st ep

specified by the second byt e. After t he measur ements, you must trigger t he calculat ion st ep to complete the

calibration.

After receiving the calculat ion byt e, the S ite Ma ster checks to see if a ll three calibrat ion st eps a re completed.

The Site Ma ster calculates t he result ing correction fa ctors a nd sends a n Operat ion C omplete Byt e #255

(FFh ) to the computer. I f a ll t hree steps are not complete, the Site Ma ster r eturns a n Operat ion I ncompleteByte #224 (E0h) and no calculation is performed.

B y t es t o F o l l o w :    2 bytes

1) Ca libration St ep to trigger

01h = open

02h = short

03h = load

18 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 25/49

0 4h = Ca lcu la t e Ca l ib ra t ion D a t a

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte224 (E0h) Er ror : Inva lid Ca l opera tion or C al I ncomplete

238 (EE h) Time-out E rror

Set Site Master data points - Control Byte #14 (0Eh)

D e sc r i p t i o n :    Sets th e number of measurement da ta points for the Site Master mode.

B y t es t o F o l l o w :    1 byte

1)Measurement Data Points

00h = 130 Points

01h = 259 Points

02h = 517 Points

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte2 24 (E 0 h ) P a ra m e t er E rro r : I n va l id D a t a P oin t S e t t in g

238 (EE h) Time-out E rror

Store sweep trace - Control Byte #16 (10h)

D e sc r i p t i o n :    Saves current trace.

Note:   Any calibra tion steps performed in remote mode overwr ite the tr ace dat a in the memory.

B y t es t o F o l l o w :    0 bytes

S i t e M a s t er R et u r n s :     5 bytes

1-4) Time/Da te St a mp (In long int eger forma t)

5) O pe ra t i on r es u lt : 255 (F F h ) O pe r a t ion C om p le t e B y t e

224 (E0h) Out of Memory (Memory Fu ll)

238 (EEh) Time-out Error

Recall sweep trace - Control Byte #17 (11h)

D e sc r i p t i o n :    Queries the Site Master for sweep trace data .

B y t es t o F o l l o w :    1 byte

0 - Last sweep trace before entering remote mode (sweep trace in RAM)

1 - 200 = Specific saved sweep number (stored sweeps in Flash memory)

S i t e M a s t er R et u r n s :  

1-2) # of following bytes (1130 for a valid sweep)

3-4) R es er v ed b y t es

S113B, S114B, S331B, S332B PM 19

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 26/49

5-11) Model Number (7 bytes in ASC II)

12-15) Softw a re Version (4 bytes in ASC II )

16) M ea s u r em en t M od e

17-20) Time/Da te (in Long In teger )

21-30) Da te in S tr ing Form a t (mm/dd/yyy y)

31-38 Time in String Format (hh:mm:ss)

39-54) Reference number sta mp55-56) # da ta points

For all “Site Ma ster Mode”:

57) S t a r t F r e q ue ncy (h i gh es t b y t e)

58) S t a r t F r eq u en cy

59) S t a r t F r eq u en cy

60) S t a r t F r e q ue ncy (l ow e s t b y t e)

61) S t o p F r e q ue ncy (h i gh es t b y t e)

62) S t op F r eq u en cy

63) S t op F r eq u en cy

64) S t o p F r e q ue ncy (l ow e s t b y t e)

6 5) M in im u m F re qu e n cy S t e p S iz e (h ig h est b yt e )

66) M in i m um F r e q ue ncy S t e p S i z e67) M in i m um F r e q ue ncy S t e p S i z e

6 8) M in im u m F re qu e n cy S t e p S iz e (lowe st b yt e )

6 9) S ca le Top (h ig h est b yt e )

70) S ca l e Top

71) S ca l e Top

7 2) S ca le Top (lowe st b yt e )

73) S c a l e B o t t om (h i gh es t b y t e)

74) S ca le B ot t om

75) S ca le B ot t om

76) S c a l e B o t t om (l ow e s t b y t e)

77) F r e q ue ncy M a r k er 1 (h i gh er b y t e)

78) F r e q ue ncy M a r k er 1 (l ow e r b y t e)

79) F r e q ue ncy M a r k er 2 (h i gh er b y t e)80) F r e q ue ncy M a r k er 2 (l ow e r b y t e)

81) F r e q ue ncy M a r k er 3 (h i gh er b y t e)

82) F r e q ue ncy M a r k er 3 (l ow e r b y t e)

83) F r e q ue ncy M a r k er 4 (h i gh er b y t e)

84) F r e q ue ncy M a r k er 4 (l ow e r b y t e)

85) L im it (h ig hes t b y te)

86) L im it

87) L im it

88) L im it (l ow e st b yt e)

89) S t a r t D i s t a n ce (h i gh es t b y t e)

90) S t a rt D is ta n ce

91) S t a rt D is ta n ce

92) S t a r t D i s t a n ce (l ow e s t b y t e)93) S t o p D i s t a n ce (h i gh es t b y t e)

94) S t op D is ta n ce

95) S t op D is ta n ce

96) S t o p D i s t a n ce (l ow e s t b y t e)

97) D i s t a n ce M a r k er 1 (h i gh er b y t e)

98) D i s t a n ce M a r k er 1 (l ow e r b y t e)

99) D i s t a n ce M a r k er 2 (h i gh er b y t e)

1 00 ) D ist a n ce M a rk e r 2 (lowe r b yt e )

20 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 27/49

1 01 ) D ist a n ce M a rk e r 3 (h ig h er b yt e )

1 02 ) D ist a n ce M a rk e r 3 (lowe r b yt e )

1 03 ) D ist a n ce M a rk e r 4 (h ig h er b yt e )

1 04 ) D ist a n ce M a rk e r 4 (lowe r b yt e )

105) Relative P ropaga tion Velocity (highest byte)

1 06 ) Re la t ive P rop a g a t io n Ve locit y

1 07 ) Re la t ive P rop a g a t io n Ve locit y108) Relative P ropaga tion Velocity (lowest byte)

1 09 ) Ca b le L oss (h ig h est b yt e )

110) C a b le L os s

111) C a b le L os s

11 2) Ca b le L oss (lowe st b yt e )

113) S t a t u s B y t e 1: (0 = O f f, 1 = O n )

(LSB ) bit 0 : Mar ker 1 On/Off

bit 1 : Ma rker 2 On/Off

bit 2 : Ma rker 3 On/Off

bit 3 : Ma rker 4 On/Off

bit 4-7 : Not U sed

114) S t a t u s b y t e 2 : (0 = O f f , 1 = O n )

(L S B ) b i t 0 : Not Use dbit 1 : Ma rker 2 D elta On/Off

bit 2 : Ma rker 3 D elta On/Off

bit 3 : Ma rker 4 D elta On/Off

bit 4-7 : Not U sed

115) S t a t u s b y t e 3 : (0 = O f f , 1 = O n )

(LSB ) bit 0 : Limit On/Off

bit 1-3 : Curr ently U nused

bit 4 : Ca l On/Off

bit 5 : Not U sed

bit 6 : Unit of Measur ement (1 = metric, 0 = English)

bit 7 : Not U sed

116) S t a t u s b yt e 4 :

(LS B ) bit 0-1: DTF Windowin g Mode

bit : 1 0

| |

0 0 - Recta ngula r (No Windowin g)

0 1 - Nomina l S ide Lobe

1 0 - Low Side L obe

1 1 - Minimum Side L obe

bit 2-7: Currently Unused

117-126) Reserved B yt es

127-1166) Sw eep Da ta (130 point s * 8 byt es/point = 1040 byt es)

127-2198) (259 poi nt s * 8 b y tes /poi nt = 2072 b y tes )

127-4262) (517 poi nt s * 8 b y tes /poi nt = 4136 b y tes )

8 bytes for each da ta point1 . g a m m a M S B

2 . g a m m a

3 . g a m m a

4 . g a m m a L S B

5. pha se MSB

6. pha se

7. pha se

8. pha se LSB

S113B, S114B, S331B, S332B PM 21

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 28/49

Note:   return loss = - 20* log(gam ma )

VS WR = ( 1+ g a m m a )/(1 -g a m m a )

phase compares the reflected to the incident (reference)

For Spectrum Analyzer Mode:

57) S t a r t F r e q ue ncy (h i gh es t b y t e)

58) S t a r t F r eq u en cy59) S t a r t F r eq u en cy

60) S t a r t F r e q ue ncy (l ow e s t b y t e)

61) S t o p F r e q ue ncy (h i gh es t b y t e)

62) S t op F r eq u en cy

63) S t op F r eq u en cy

64) S t o p F r e q ue ncy (l ow e s t b y t e)

65) C e n t er F r e q ue ncy (h i gh es t b y t e)

66) C e nt er F r eq u en cy

67) C e nt er F r eq u en cy

68) C e n t er F r e q ue ncy (l ow e s t b y t e)

69) F r e q ue ncy S p a n (h i gh es t b y t e)

70) F r eq u en cy S pa n

71) F r eq u en cy S pa n72) F r e q ue ncy S p a n (l ow e s t b y t e)

7 3) M in im u m F re qu e n cy S t e p S iz e (h ig h est b yt e )

74) M in i m um F r e q ue ncy S t e p S i z e

75) M in i m um F r e q ue ncy S t e p S i z e

7 6) M in im u m F re qu e n cy S t e p S iz e (lowe st b yt e )

77) R e f L ev el (h i gh es t b y t e)

78) R ef L evel

79) R ef L evel

80) R e f L ev el (l ow e s t b y t e)

81) S c a l e p er d i v (h i gh es t b y t e)

82) S ca l e per d iv

83) S ca l e per d iv

84) S c a l e p er d i v (l ow e s t b y t e)

85) F r e q ue ncy M a r k er 1 (h i gh er b y t e)

86) F r e q ue ncy M a r k er 1 (l ow e r b y t e)

87) F r e q ue ncy M a r k er 2 (h i gh er b y t e)

88) F r e q ue ncy M a r k er 2 (l ow e r b y t e)

89) F r e q ue ncy M a r k er 3 (h i gh er b y t e)

90) F r e q ue ncy M a r k er 3 (l ow e r b y t e)

91) F r e q ue ncy M a r k er 4 (h i gh er b y t e)

92) F r e q ue ncy M a r k er 4 (l ow e r b y t e)

93) L im it (h ig hes t b y te)

94) L im it

95) L im it

96) L im it (l ow e st b yt e)97) R B W S e t t in g (h i gh es t b y t e)

98) R B W S et tin g

99) R B W S et tin g

1 00 ) RB W S e t t in g (lowe st b yt e )

1 01 ) V B W S e t t in g (h ig h est b yt e )

102) VB W S et t in g

103) VB W S et t in g

1 04 ) V B W S e t t in g (lowe st b yt e )

105) O C C B W M et h od

22 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 29/49

1 06 ) OCC B W % Va lu e (h ig h est b yt e )

107) O C C B W % Va l u e

108) O C C B W % Va l u e

1 09 ) OCC B W % Va lu e (lowe st byt e )

11 0) OCC B W d B c (h ig h est b yt e )

111) O CC B W d B c

112) O CC B W d B c11 3) OCC B W d B c (lowe st b yt e )

11 4) At t e n u a t io n (h ig h est b yt e )

115) At t e n ua t i on

116) At t e n ua t i on

11 7) At t e n u a t io n (L owe st b yt e )

118) S t a t u s B y t e 1: (0 = O f f, 1 = O n )

(LSB ) bit 0 : Mar ker 1 On/Off

bit 1 : Ma rker 2 On/Off

bit 2 : Ma rker 3 On/Off

bit 3 : Ma rker 4 On/Off

bit 4-7 : Not U sed

119) S t a t u s b y t e 2 : (0 = O f f , 1 = O n )

(L S B ) b i t 0 : Not Use dbit 1 : Ma rker 2 D elta On/Off

bit 2 : Ma rker 3 D elta On/Off

bit 3 : Ma rker 4 D elta On/Off

bit 4-7 : Not U sed

120) S t a t u s b y t e 3 : (0 = O f f , 1 = O n )

(LSB ) bit 0 : Limit On/Off

bit 1-7 : Not U sed

121-130) Reserved B yt es

131-1730) Sw eep Da ta (400 point s * 4 byt es/point = 1600 byt es)

4 bytes for each da ta point

1. sweep value MSB

2. sweep value

3. sweep value

4. sweep value LS B

For invalid sweeps(empty stored sweep locations):  only 11 bytes w ill return:

1-2) Number of follow ing by tes (9 bytes for inva lid sw eep reca ll)

3-4) Model # (unsign ed int eger, 0x00 for Sit e Ma ster)

5-11) Ext ended Model # (7 bytes in ASC II )

Invalid sweep location:  1 b yt e

224 (E0) : P ar am eter error : I nvalid sw eep location

Notes: P lease refer to Control Byt es 02h through 0Ah for data forma ts.

Minimum Frequency Step Size is in HzGamma is in  thousandths (of ra tio)

Phase is in  tenths of a degree

For Spectrum Analyzer Mode:dB m va lue is obta ined by: dB m va lue = (sw eep va lue – 270,000)/1000

S113B, S114B, S331B, S332B PM 23

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 30/49

Save system setup - Control Byte #18 (12h)

D e sc r i p t i o n :    Sa ves current s ystem setup par am eters to a specific setup store locat ion.

The Site Ma ster sa ves all par am eters described in Syst em St at us Query - Control Byt e #20 (14h) to the spec-

ified store location. Store location 0 is the run-time setup of the Site Master. It holds the power-on defaults ofthe Site Master.

B y t es t o F o l l o w :    1 byte

1) Locat ion t o save syst em setup par am eters, 0 - 10

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte224 (E0h) P ar am eter Error : Inva lid store location

238 (EE h) Time-out E rror

Recall system setup - Control Byte #19 (13h)D e sc r i p t i o n :    Recalls syst em setup para meters from a specific store location.

The Site Ma ster recalls all par am eters described in Syst em St at us Query (14h) (except S erial P ort Echo Sta -

tus ) from t he specified st ore locat ion. The recalled s etup does not aut oma tically become the default setup

wh en exit ing remote.

You may w an t t o save the r ecalled setup a s th e run-time setup by sa ving it t o setup locat ion 0 (w hich holds

th e power-on defa ults). S ee cont rol byt e #18 (12h) for deta ils.

B y t es t o F o l l o w :    1 byte

1) Locat ion t o recall sy stem setup pa ra meters from:

0 = Run-time setup1 - 10 = Sa ved setups

255 = D efault setup

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte224 (E0h) P ar am eter Err or : Invalid store location or no saved setup

238 (EE h) Time-out E rror

Query system status - Control Byte #20 (14h)

D e sc r i p t i o n :    Queries the Site Mast er for current system sett ings.

The current sta te of the Sit e Mast er represents the st at e aft er last successful remote control operat ion.

P lease refer t o Control bytes 01h th rough 0Ah for dat a forma ts.

B y t es t o F o l l o w :    0 bytes

S i t e M a s t er R et u r n s :     171 byt es

1) M ea s ur em en t M od e

2) S i t e M a s t er M od e D a t a P o in t s (h ig h er b yt e)

24 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 31/49

3) S i t e M a s t er M od e D a t a P o in t s (l ow e r b yt e)

4) S t a r t F r eq u en cy (h ig hes t b y t e)

5) S ta rt F req uen cy

6) S ta rt F req uen cy

7) S t a r t F r eq u en cy (l ow e st b yt e)

8) S t op F r eq u en cy (h ig h es t b y te)

9) S top F req uen cy10) S t op F r eq u en cy

11) S t o p F r e q ue ncy (l ow e s t b y t e)

12) S ca l e S t a r t (h ig h er b yt e)

13) S ca le S ta r t

14) S ca le S ta r t

15) S ca l e S t a r t (l ow e r b y te)

16) S c a le S t o p (h i gh er b y t e)

17) S ca le S t op

18) S ca le S t op

19) S c a le S t o p (l ow e r b y t e)

20) F r eq u en cy M a r k er 1 (h i gh er b y t e)

21) F r eq u en cy M a r k er 1(l ow e r b y t e)

22) F r eq u en cy M a r k er 2 (h i gh er b y t e)23) F r eq u en cy M a r k er 2 (l ow e r b y t e)

24) F r eq u en cy M a r k er 3 (h i gh er b y t e)

25) F r eq u en cy M a r k er 3 (l ow e r b y t e)

26) F r eq u en cy M a r k er 4 (h i gh er b y t e)

27) F r eq u en cy M a r k er 4 (l ow e r b y t e)

28) L im it (h ig her b y te)

29) L im it

30) L im it

31) L im it (l ow e r b yt e)

32) S t a r t D i s t a n ce (h i gh es t b y t e)

33) S t a rt D is ta n ce

34) S t a rt D is ta n ce

35) S t a r t D i s t a n ce (l ow e s t b y t e)

36) S t o p D i s t a n ce (h i gh es t b y t e)

37) S t op D is ta n ce

38) S t op D is ta n ce

39) S t o p D i s t a n ce (l ow e s t b y t e)

40) D i s t a n ce M a r k er 1 (h i gh er b y t e)

41) D i s t a n ce M a r k er 1 (l ow e r b y t e)

42) D i s t a n ce M a r k er 2 (h i gh er b y t e)

43) D i s t a n ce M a r k er 2 (l ow e r b y t e)

44) D i s t a n ce M a r k er 3 (h i gh er b y t e)

45) D i s t a n ce M a r k er 3 (l ow e r b y t e)

46) D i s t a n ce M a r k er 4 (h i gh er b y t e)

47) D i s t a n ce M a r k er 4 (l ow e r b y t e)4 8) Re la t ive P rop a g a t io n Ve locit y (h ig h est b yt e )

4 9) Re la t ive P rop a g a t io n Ve locit y

5 0) Re la t ive P rop a g a t io n Ve locit y

5 1) Re la t ive P rop a g a t io n Ve locit y (lowe st b yt e )

52) C a b l e L os s (h i gh es t b y t e)

53) C a ble L os s

54) C a ble L os s

55) C a b l e L os s (l ow e s t b y t e)

5 6) S p ect ru m An a lyz e r M od e D a t a Po in t s (h ig h er b yt e )

S113B, S114B, S331B, S332B PM 25

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 32/49

5 7) S p e ct ru m An a lyz e r M od e D a t a Po in t s (lowe r b yt e )

5 8) S p e ct ru m An a lyz e r S t a rt F re qu en cy (h ig h est b yt e )

59) S p ect r u m An a l y z er S t a r t F r eq u en cy

60) S p ect r u m An a l y z er S t a r t F r eq u en cy

6 1) S p e ct ru m An a lyz e r S t a rt F re qu en cy (lowe st b yt e )

6 2) S p e ct ru m An a lyz e r S t o p F re qu e n cy (h ig h est b yt e )

63) S p ect r u m An a l y z er S t o p F r e q ue ncy64) S p ect r u m An a l y z er S t o p F r e q ue ncy

6 5) S p e ct ru m An a lyz e r S t o p F re qu e n cy (lowe st b yt e )

6 6) S p e ct ru m An a lyz e r Ce n t e r F re qu e n cy (h ig h est b yt e )

67) S p ect r u m An a l y z er C e n t er F r e q ue ncy

68) S p ect r u m An a l y z er C e n t er F r e q ue ncy

6 9) S p e ct ru m An a lyz e r Ce n t e r F re qu e n cy (lowe st b yt e )

7 0) S p e ct ru m An a lyz e r F re qu en cy S p a n (h ig h est b yt e )

71) S p ect r u m An a l y z er F r eq u en cy S p a n

72) S p ect r u m An a l y z er F r eq u en cy S p a n

7 3) S p e ct ru m An a lyz e r F re qu en cy S p a n (lowe st b yt e )

7 4) S p e ct ru m An a lyz e r M in im u m F re qu e n cy S t e p S iz e (h ig h est b yt e )

7 5) S p e ct ru m An a lyz e r M in im u m F re qu e n cy S t e p S iz e

7 6) S p e ct ru m An a lyz e r M in im u m F re qu e n cy S t e p S iz e7 7) S p e ct ru m An a lyz e r M in im u m F re qu e n cy S t e p S iz e (lowe st byt e )

78) R e f L ev el (h i gh es t b y t e)

79) R ef L evel

80) R ef L evel

81) R e f L ev el (l ow e s t b y t e)

82) S c a l e p er d iv (h i gh es t b y t e)

83) S ca l e per d iv

84) S ca l e per d iv

85) S c a l e p er d iv (l ow e s t b y t e)

8 6) S p e ct ru m An a lyz e r F re qu en cy M a rk e r 1 (h ig h er b yt e )

8 7) S p e ct ru m An a lyz e r F re qu en cy M a rk e r 1 (lowe r b yt e )

8 8) S p e ct ru m An a lyz e r F re qu en cy M a rk e r 2 (h ig h er b yt e )

8 9) S p e ct ru m An a lyz e r F re qu en cy M a rk e r 2 (lowe r b yt e )

9 0) S p e ct ru m An a lyz e r F re qu en cy M a rk e r 3 (h ig h er b yt e )

9 1) S p e ct ru m An a lyz e r F re qu en cy M a rk e r 3 (lowe r b yt e )

9 2) S p e ct ru m An a lyz e r F re qu en cy M a rk e r 4 (h ig h er b yt e )

9 3) S p e ct ru m An a lyz e r F re qu en cy M a rk e r 4 (lowe r b yt e )

9 4) S p e ct ru m An a lyz e r L im it (h ig h est b yt e )

95) S p ect r u m An a l y z er L i m it

96) S p ect r u m An a l y z er L i m it

9 7) S p e ct ru m An a lyz e r L im it (lowe st b yt e )

98) R B W S e t t in g (h i gh es t b y t e)

99) R B W S et tin g

100) R B W S et t in g

1 01 ) RB W S e t t in g (lowe st b yt e )1 02 ) V B W S e t t in g (h ig h est b yt e )

103) VB W S et t in g

104) VB W S et t in g

1 05 ) V B W S e t t in g (lowe st b yt e )

106) O C C B W M et h od

1 07 ) OCC B W % Va lu e (h ig h est b yt e )

108) O C C B W % Va l u e

109) O C C B W % Va l u e

11 0) OCC B W % Va lu e (lowe st byt e )

26 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 33/49

111 ) OCC B W d B c (h ig h est b yt e )

112) O CC B W d B c

113) O CC B W d B c

11 4) OCC B W d B c (lowe st b yt e )

11 5) At t e n u a t io n (h ig h est b yt e )

116) At t e n ua t i on

117) At t e n ua t i on11 8) At t e n u a t io n (lowe st b yt e )

119-148) Reserved B yt es

149) S t a t u s B y t e 1: (0 = O f f, 1 = O n )

(LSB ) bit 0 : Site Mast er Marker 1 On/Off

bit 1 : Sit e Mas ter Ma rker 2 On/Off

bit 2 : Sit e Mas ter Ma rker 3 On/Off

bit 3 : Sit e Mas ter Ma rker 4 On/Off

bit 4-7 : Not U sed

150) S t a t u s b y t e 2 : (0 = O f f , 1 = O n )

(L S B ) b i t 0 : Not Use d

bit 1 : Site Ma ster Ma rker 2 Delta On/Off

bit 2 : Site Ma ster Ma rker 3 Delta On/Off

bit 3 : Site Ma ster Ma rker 4 Delta On/Offbit 4-7 : Not U sed

151) S t a t u s B y t e 3: R es er v ed B y t e

152) S t a t u s by t e 4 : R es er v ed B y t e

153) S t a t u s B y t e 5: (0 = O f f, 1 = O n )

(LSB ) bit 0 : Spectrum Analyzer Mar ker 1 On/Off

bit 1 : S pectr um Ana lyzer Ma rker 2 On /Off

bit 2 : S pectr um Ana lyzer Ma rker 3 On /Off

bit 3 : S pectr um Ana lyzer Ma rker 4 On /Off

bit 4-7 : Not U sed

154) S t a t u s b y t e 6 : (0 = O f f , 1 = O n )

(L S B ) b i t 0 : Not Use d

bit 1 : Spectrum Ana lyzer Ma rker 2 Delta On/Off

bit 2 : Spectrum Ana lyzer Ma rker 3 Delta On/Off

bit 3 : Spectrum Ana lyzer Ma rker 4 Delta On/Off

bit 4-7 : Not U sed

155) S t a t u s b y t e 7 : (0 = O f f , 1 = O n )

(LSB ) bit 0 : Site Master Limit On/Off

bit 1-3 : Curr ently U nused

bit 4 : Site Ma ster C a l On/Off

bit 5 : Not U sed

bit 6 : Sit e Mas ter L imit B eep On/Off

bit 7 : Not U sed

156) S t a t u s by t e 8 : R es er v ed B y t e

157) S t a t u s b y t e 9 : (0 = O f f , 1 = O n )

(LSB ) bit 0 : Spectrum Analyzer Limit On/Offbit 1-3 : Curr ently U nused

bit 4 : Not U sed

bit 5-7 : Not U sed

158) S t a t u s b yt e 10 :

(LS B ) bit 0-1: DTF Windowin g Mode

bit : 1 0

| |

0 0 - Recta ngula r (No Windowin g)

0 1 - Nomina l S ide Lobe

S113B, S114B, S331B, S332B PM 27

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 34/49

1 0 - Low Side L obe

1 1 - Minimum Side L obe

bit 2-7: Currently Unused

159) S t a t u s b yt e 11 :

(LS B ) bit 0 : Fixed CW Mode On/Off

bit 1 : Currently Unused

bit 2 : LCD B a ck Light On/Offbit 3 : Measu rement U nit Metr ic/En glish (0 = E nglish, 1 = Met ric)

bit 4-7 : Curr ently U nused

160) Seria l P ort Echo St at us On/~ Off (1= On, 0= Off)

161) P r i n t er Ty p e

162-171) Current ly U nused

Note:   B i t Va l u e: 0 = Of f

1 = On

Trigger self-test - Control Byte #21 (15h)

D e sc r i p t i o n :    Triggers a s elf test on the Sit e Mast er.

B y t es t o F o l l o w :    0 B y t e s

S i t e M a s t er R et u r n s :     12 byt es

1) Self-test report : (0 = Fa il , 1 = P ass)

(LSB ) bit 0 : Pha se Lock Loop

bit 1 : Integrat or

b it 2 : B a t t e ry

bit 3 : Temperat ure

bit 4 : EE P ROM read /wr ite

bit 5- 7 : Not currently used.2) Self-test report : (0 = Fa il , 1 = P ass)

(LSB ) bit 0 : Spectrum Ana lyzer Lock

bit 1- 7 : Spectrum Analyzer Measurement

3) Ba tt ery Volta ge(higher byt e)

4) Battery Voltage(lower byte)

5) Temperat ure (higher byt e)

6) Temperat ure (lower byt e)

7) Lock Fail Counter (higher byte)

8) Lock Fail Counter (lower byte)

9) Int egrat or F ail C ounter (higher byte)

10) Integrat or Fa il Counter (lower byt e)

11) Spectrum Analyzer Lock Fail Counter (higher byte)

12) Spectrum Analyzer Lock Fail Counter (lower byte)

Notes: B a tt ery Volta ge in 1/10th of a Volt (e.g. 124 = 12.4 Volts)

Tempera tu re in 1/10th of degr ee Celsiu s (e.g. 362 = 36.2  C) or degr ee Fah renheit (e.g. 934 = 93.4   F ),

depending on the current measurement unit (Metric or English) selected.

28 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 35/49

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 36/49

Delete Sweep Trace - Control Byte #25 (19h)

D e sc r i p t i o n :   Delete single or all st ored sw eep tra ces in S ite Mast er.

B y t es t o F o l l o w :    1 byte0 - Delete a ll Tra ces

X - Delete S ingle Tra ce #X

S i t e M a s t er R et u r n s :     225 (FF h) Operat ion Complete B yt e

Select Printer Type - Control Byte #30 (1Eh)

D e sc r i p t i o n :   Select Printer Type

B y t es t o F o l l o w :    1 byte0 - No Pr inter Selected

1 - Seiko DP U 411, 414

2 - HP Deskjet 340

3 - HP Deskjet 500, 500C, 540C

4 - HP Deskjet 670C, 672C, 692C

5 - HP Deskjet 870Cxi, 890C

6 - HP Deskjet 1120C

7 - HP La serjet 6L, 6P, 4000

8 - NE C Superscript 760C

S i t e M a s t er R et u r n s :     225 (FF h) Operat ion Complete B yt e

Select DTF Windowing - Control Byte #31 (1Fh)

D e sc r i p t i o n :    Select DTF Windowin g Methods.

DTF Windowing allows y ou to ma ke a tra de off betw een side lobe height a nd r esolution.

B y t es t o F o l l o w :    1 byte

00h = Rectangular (finest resolution, highest side lobes)

01h = Nominal Side Lobe (balance between resolution and side lobes)

02h = Low Side Lobe

03h = Minimum Side Lobe

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte224 (E0h) P ar am eter Err or : Invalid DTF Window ing Methods

238 (EE h) Time-out E rror

30 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 37/49

Set Trace Math - Control Byte #32 (20h)

D e sc r i p t i o n :    S e t u p t ra ce m a t h o pe ra t ion a n d t ra ce

B y t es t o F o l l o w :    2 bytes1)Tra ce Mat h Operat ion (0 to 5)

00h = Off

01h = Addition

02h = Subtraction

2) Tra ce to Perform Ma th Operat ion on (1 to 50)

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte224 (E0h) P ar am eter Err or : Invalid Tra ce Opera tion

238 (EE h) Time-out E rror

Query Power L evel - Control Byte #39 (27h)

D e sc r i p t i o n :    Return Power Level at Detector Port

This control byte conta ins a ll the informat ion you need to determine just a bout a nyth ing a bout a pow er mon-

itor measurement.

B y t es t o F o l l o w :    0 byte

S i t e M a s t er R et u r n s :     21 byt es

1) S t a t u s B y t e

(LS B ) bit 0 : U nit (0 - Wa tt /%, 1 - dB m/dB r)

bit 2 : Relat ive Mode On/~ Off

bit 3 : Offs et Mode On /~ Off

bit 4 : Zero Mode On /~ Off

bit 5-7: Not current ly us ed.

2 - 5) Relat ive Mode Reference P ower L evel in dB m

6 - 9) Offset Mode Offset in d B

10 - 13) Zero Mode P ower Level in dB m

14 - 17) Absolute P ower L evel in dB m

18 - 21) P ower in d B m/dB r

Notes: You can query power level without setting power monitor mode ON.

Absolute P ower of –100 indicat es a ha rdw ar e failure (P ower monitor mode unavaila ble or

RF Detector not connected)Power is in   one-thousandth of dB m

Relative pow er is in   one-thousandth of dB r

Offset is in   one-thousandth of dB

S113B, S114B, S331B, S332B PM 31

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 38/49

Set Power Monitor Unit - Control Byte #40 (28h)

D e sc r i p t i o n :    Set P ower Monitor unit to Wat ts or dBm

B y t es t o F o l l o w :    1 byte00h = Watt (%if in relative mode)

01h = dB m (dB r if in relat ive mode)

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte224 (E0h) P ar am eter Error : Inva lid pow er monitor unit

238 (EE h) Time-out E rror

Relative Mode On/Off - Control Byte #41 (29h)

D e sc r i p t i o n :    Ena ble or disa ble Power Monitor Relat ive Mode

B y t es t o F o l l o w :    1 byte

00h = Off

01h = On w/trigger (use the current power level as a reference power level.)

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte2 24 (E 0 h ) P a ra m e t er E rro r : I n va l id p a ra m e t e r

238 (EE h) Time-out E rror

Offset Mode On/Off - Control Byte #42 (2Ah)

D e sc r i p t i o n :    Ena ble or disa ble Power Monitor Offset Mode

B y t es t o F o l l o w :    5 bytes

1) On/~ Off (01 = On, 00 = Off)

2-5) Offset P ower Level in dB

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte2 24 (E 0 h ) P a ra m e t er E rro r : I n va l id p a ra m e t e r

238 (EE h) Time-out E rror

Note:   I f you tur n t he Offset mode off , you must st ill send t he other bytes. B ytes 2 - 5 will be ignored.

32 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 39/49

Zero Mode On/Off - Control Byte #43 (2Bh)

D e sc r i p t i o n :    Enable or disable Power Monitor Zeroing Mode.

B y t e s t o F o l l o w :    1 b yt e00h = Off

01h = On w/trigger(current power level is referenced as –80 dBm.)

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete Byt e224 (E0h) Parameter Error : Invalid parameter

238 (E E h) Time-out E rr or

Trigger sweep - Control Byte #48 (30h)

D e sc r i p t i o n :    Ca uses the Site Ma ster t o perform a sweep if it is in single sw eep or serial port echo mode.

B y t e s t o F o l l o w :    0 bytes

S i t e M a s t er R et u r n s :     Sw eep Complete B yt e # 192 (C0h)

Note:   I f t h e S it e M a st e r is   not   in single sweep or serial port echo mode, sending the byte does nothing.

This command is for local mode operation. If the Site Master is in remote mode, sending the byte does

nothing.

Check Battery Status - Control Byte #50 (32h)

D e sc r i p t i o n :    Re t u rn s sm a rt b a t t e ry st a t u s.

B y t e s t o F o l l o w :    0 bytes

S i t e M a s t er R et u r n s :     17 byt es

1 -2 ) B a t t e ry S t a t u s f la g s (Re fe r t o S m a rt B a t t e ry D a t a S p ec 5 .1 .2 .1 )

3-4) St at e of Cha rge (unsigned integer 0 to 100(%) Full)

5-6) B at tery Volta ge (unsigned integer 0 to 65535 in mV)

7-8) B at tery Curr ent (signed integer –32,768 to + 32,7687 mA, posit ive = Cha rging)

9-10) B a tt ery Avera ge Curr ent (signed integer –32,768 to + 32,7687 mA, positive = Ch a rging)

11-12) Avera ge time t o empty (unsigned int eger 0 to 65535 minut e)

13-14) B a tt ery Ch a rge Cy cle Count (unsigned integer 0 to 65535 cycles)

15-16) B at tery C apa city at Full Ch ar ge in mA Hours (unsigned integer 0 to 65535 cycles)

1 7) Un it u n d er b a t t e ry powe r (1 = Ye s, 0 = N o)

S113B, S114B, S331B, S332B PM 33

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 40/49

Automatically Save Runtime Setup - Control Byte #64 (40h)

D e sc r i p t i o n :   Automat ically save t he runt ime setup when exit ing remote mode.

This f lag must be set once per pow er cycle of the S ite Mast er. I t returns t o its default wh en the unit is t urned

off. The default is (0), D o Not aut oma tically sa ve the runtime setup.

B y t es t o F o l l o w :   1 b yt e

1) Sa ve run tim e setup On/Off

0 = Of f

1 = On

S i t e M a s t er R et u r n s :     255 (FF h) Operat ion Complete238 (EEh) Time-out Error

Enter remote mode - Control Byte #69 (45h)D e sc r i p t i o n :    Ent er remote mode then send model number a nd firmw ar e version to the computer

B y t es t o F o l l o w :    0 bytes

S i t e M a s t er R et u r n s :     13 byt es

1-2) Model # (unsign ed int eger, 0x00 for Sit e Ma ster)

3-9) Ext ended Model # (7 bytes in ASC II )

10-13) Softw a re Version - 4 byt es (ASC II )

The computer sends En ter R emote mode byte #69 (45h) to the S ite Ma ster an d w ait s for r esponse.

Since the Site Ma ster polls its serial port buffer at the end of each sw eep, the computer must wa it unt il theSite Ma ster sends th e return byt es before sending a n ew control byte. Otherw ise, the new control byte

overwr ites the old one (say ing enter r emote) and the S ite Ma ster does not respond a s expected.

Once in remote mode, the S ite Ma ster st ops sw eeping. A Remote Mode Indicator a ppear s on t he LC D.

The Site Ma ster sends its model a nd softwa re version num bers to the computer. The Site Ma ster is n ow able

to ta ke multiple control bytes. I t wa its for the next contr ol byte.

Enter Remote Mode Immediately - Control Byte #70 (46h)

D e sc r i p t i o n :   Ent er remote mode in the middle of a sw eep, then send the model number a nd firmw ave ver-

sion to t he computer.

B y t es t o F o l l o w :   0 bytes

S i t e M a s t er R et u r n s :     13 byt es

1-2) Model # (unsigned integer)

3-9) Ext ended Model # (7 bytes in ASC II )

10-13) Softw a re Version - 4 byt es (ASC II )

34 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 41/49

The computer sends E nter R emote Mode Immediately byt e #70 (46h) to the Site Ma ster a nd w ait s for a re-

sponse. This control byte causes the unit to enter remote mode immediately. Note that this could result in in-

complete sw eep da ta . U se contr ol byte #69 if complete da ta is required.

Once in remote mode, the S ite Ma ster st ops sw eeping. A Remote Mode Indicator a ppear s on th e LCD .

The Site Ma ster sends its model a nd softwa re version num bers to the computer. The Site Ma ster is n ow able

to ta ke multiple control bytes. I t wa its for the next control byte.

Write Custom Cable - Control Byte #80 (50h)

D e sc r i p t i o n :    Write a cable par am eter in the custom cable list .

B y t es t o F o l l o w :    24 bytes

1) Ca ble List Index

2-16) Ca ble D escription (str ing)

17) Pr opa ga tion Velocity (highest by te)

18) P ropaga tion Velocity19) P ropaga tion Velocity

20) Pr opa ga tion Velocity (low est by te)

21) Insertion Loss (highest byte)

22) Insert ion Loss

23) Insert ion Loss

24) Insert ion Loss (lowest byt e)

S i t e M a s t er R et u r n s :     225 (FF h) Operat ion Complete224 (E0h) Pa ra meter E rror

238 (EEh) Time-out Error

Recall Custom Cable - Control Byte #81 (51h)

D e sc r i p t i o n :    Query a ca ble in the custom cable list .

B y t es t o F o l l o w :    1 byte

1)Cable list index (1 - 49)

S i t e M a s t er R et u r n s :     23 byt es

1) U pper B ound of Cust om Ca ble Index

2-16) Ca ble D escription (str ing)

17) Pr opa ga tion Velocity (highest by te)

18) P ropaga tion Velocity19) P ropaga tion Velocity

20) Pr opa ga tion Velocity (low est by te)

21) Insertion Loss (highest byte)

22) Insert ion Loss

23) Insert ion Loss

24) Insert ion Loss (lowest byt e)

S113B, S114B, S331B, S332B PM 35

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 42/49

Measure OCC BW % of Power - Control Byte #96 (60h)

D e sc r i p t i o n :    Measure OCC BW with %of Power method.

B y t es t o F o l l o w :    4 bytes1) %of Power (highest byte)

2) %of P ower

3) %of P ower

4) %of Power (lowest byte)

S i t e M a s t er R et u r n s :     16 byt es

1-4) OC C B W

5-8) M ea s u r e % of P o w e r

9 -1 2) L ow F requ e n cy OCC B W

13-16) High Frequency OCC B W

Note:   In 100t h of %, 9123 = 91.23%

Measure OCC BW dB Down - Control Byte #97 (63h)

D e sc r i p t i o n :   M e a su re OCC B W wit h d B d own m e t h od .

B y t es t o F o l l o w :    4 bytes

1) dB down (highest byte)

2) dB down

3) dB down

4) dB down (lowest byte)

S i t e M a s t er R et u r n s :     16 byt es

1-4) OC C B W

5-8) M ea s u r e d B d ow n

9 -1 2) L ow F requ e n cy OCC B W

13-16) High Frequency OCC B W

Note:   In 100t h of dB , 1234 = 12.34 dB

Set Spectrum Analyzer Frequency - Control Byte #99 (63h)

D e sc r i p t i o n :   Sets th e Spectrum Analyzer frequency ra nge.

B y t es t o F o l l o w :    8 bytes

1) St ar t F requency (highest byte)

2) Start Frequency

3) Start Frequency

4) St ar t F requency (lowest byte)

5) Stop Frequency (highest byte)

36 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 43/49

6) St op Frequency

7) St op Frequency

8) Stop Frequency (lowest byte)

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte224 (E0h) Parameter Error : Invalid frequency range

238 (EE h) Time-out E rror

Notes: St ar t a nd stop frequencies a re given in terms of 1 Hz steps.

(e.g. 100.3 MHz would be sent as 100030000 = 1,000,300,000 Hz)

Set Spectrum Analyzer Center Freq./Span - Control Byte #100 (64h)

D e sc r i p t i o n :   Sets t he Spectrum Ana lyzer center frequency nd frequency span.

B y t es t o F o l l o w :    8 bytes

1) Center Frequency (highest byte)2) Center F requency

3) Center F requency

4) Center Frequency (lowest byte)

5) Frequency S pan (highest byt e)

6) Frequency S pan

7) Frequency S pan

8) Frequency S pan (low est byt e)

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte224 (E0h) Parameter Error : Invalid frequency range

238 (EE h) Time-out E rror

Notes: Center frequencies a nd frequency spans a re given in t erms of 1 Hz s teps.(e.g. 100.3 MHz would be sent as 100030000 = 1,000,300,000 Hz)

Set Spectrum Analyzer Scale - Control Byte #101 (65h)

D e sc r i p t i o n :    Sets the graph boundaries.

Ref Level w ill be the “top” scale of the gra ph, and there a re a total of 10 divisions, so the bottom scale can be

determined by: Ref Level – 10   dB /d iv.

B y t es t o F o l l o w :    8 bytes

1) Ref Level (highest by te)

2) Ref Level

3) Ref Level

4) Ref Level (low est byt e)

5) dB /div (high est byt e)

6) dB /di v

7) dB /di v

8) dB /div (lowes t byt e)

S113B, S114B, S331B, S332B PM 37

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 44/49

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte2 24 (E 0 h ) P a ra m e t er E rro r : I n va l id sca le ra n g e

238 (EE h) Time-out E rror

Notes: P a ra m e t ers a re se n t in 1 00 0t h of a dB (–12.34 dB = –12340)

Ref Level is sent a s: (Ref Level)   1000 + 270,000 (0 dB = 270,000, 20 dB = 290,000,

–120 dB = 150,000)

Set Spectrum Analyzer Marker - Control Byte #102 (66h)

D e sc r i p t i o n :   Sets a n individual Spectrum Ana lyzer mar ker.

B y t es t o F o l l o w :    5 bytes:

1) Mar ker Number (01h = ma rker 1, 02h = ma rker 2, 03h = ma rker 3, 04h = ma rker 4)

2) Ma rker Lin e On/~ Off (01h = On, 00h = Off)

3) Ma rker D elta On/~ Off (01h = On, 00h = Off)

4) Ma rker Va lue (higher byt e)5) Ma rker Value (lower by te)

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte224 (E0h) P ar am eter Error : Invalid ma rker, mar ker stat us, or ma rker posit ion

238 (EEh) Time-out Error

Note:   Mar ker value is between 0 an d 399.

Set Spectrum Analyzer Limit - Control Byte #103 (67h)

D e sc r i p t i o n :   Sets the posit ion a nd On/Off St at us of the L imit Line.

B y t es t o F o l l o w :    7 bytes:

1) Limit Num ber (for unit s w ith m ultiple limits, 1 for S ite Mast er)

2) Limit Line On /~ Off (01h = On, 00h = Off)

3) B eep at L imit O n/~ Off (01h = On, 00h = Off)

4) Limit Va lue (highest byt e)

5) Limit Va lue

6) Limit Va lue

7) Limit Va lue (lowest byt e)

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte

224 (E0h) P ar am eter Error : Invalid limit , limit sta tus, or limit value238 (EE h) Time-out E rror

Notes: P a ra m e t ers a re se n t in 1 00 0t h of a dB (–12.34 dB = –12340)

Ref Level is sent a s: (Ref Level)   1000 + 270,000 (0 dB = 270,000, 20 dB = 290,000,

–120 dB = 150,000)

38 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 45/49

Set Spectrum Analyzer Max Hold - Control Byte #105 (69h)

D e sc r i p t i o n :   Sets t he max h old sett ings on the S pectrum Analyzer.

B y t es t o F o l l o w :    1 byte00h = Max H old Off

01h = Max H old On

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte2 24 (E 0 h ) P a ra m e t er E rro r : I n va l id p a ra m e t e r

238 (EE h) Time-out E rror

Set Spectrum Analyzer Resolution Bandwidth Freq - Control Byte #106 (6Ah)

D e sc r i p t i o n :   Set the r esolution B W frequency for t he Spectrum Ana lyzer.

B y t es t o F o l l o w :    1 byte

00h = 10 kHz resolution BW

01h = 30 kHz resolution BW

02h = 100 kHz resolution BW

03h = 1 MHz resolution BW

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte2 24 (E 0 h ) P a ra m e t er E rro r : I n va l id p a ra m e t e r

238 (EE h) Time-out E rror

Set Spectrum Analyzer Video Bandwidth Freq - Control Byte #107 (6Bh)

D e sc r i p t i o n :   Set the video BW frequency for t he Spectrum Analyzer.

B y t es t o F o l l o w :    1 byte

00h = 3 kHz video B W

01h = 10 kHz video BW

02h = 30 kHz video BW

03h = 300 kHz video BW

S i t e M a s t er R et u r n s :     255 (FFh ) Operat ion Complete B yte

2 24 (E 0 h ) P a ra m e t er E rro r : I n va l id p a ra m e t e r238 (EE h) Time-out E rror

S113B, S114B, S331B, S332B PM 39

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 46/49

Set Spectrum Analyzer Sweep Mode - Control Byte #108 (6Ch)

D e sc r i p t i o n :   Sets the sw eep mode for t he Spectrum Analyzer.

B y t es t o F o l l o w :    1 byte00h = Single Sw eep

01h = Continuous Sweep

S i t e M a s t er R et u r n s :     255 (FFh) Opera tion Complete B yte2 24 (E 0 h ) P a ra m e t er E rro r : I n va l id p a ra m e t e r

238 (EE h) Time-out E rror

Set Spectrum Analyzer Marker to Peak - Control Byte #109 (6Dh)

D e sc r i p t i o n :   Sets the specified ma rker to the peak va lue of the sw eep.

B y t es t o F o l l o w :    1 byte

Ma rker Number (1 - 4)

S i t e M a s t er R et u r n s :     255 (FF h) Operat ion Complete B yt e224 (E0h) P ar am eter Err or : Invalid Mar ker

238 (EEh) Time-out Error

Set Spectrum Analyzer Marker to Center - Control Byte #110 (6Eh)

D e sc r i p t i o n :   Sets the center frequency equa l to th e frequency of th e specified ma rker.

B y t es t o F o l l o w :    1 byte

Ma rker Number (1 - 4)

S i t e M a s t er R et u r n s :     255 (FF h) Operat ion Complete B yt e224 (E0h) P ar am eter Err or : Invalid Mar ker

238 (EEh) Time-out Error

40 S113B, S114B, S331B, S332B PM

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 47/49

Exit remote mode - Control Byte #255 (FFh)

D e sc r i p t i o n :    Site Mast er exits remote mode

B y t es t o F o l l o w :    0 byte

S i t e M a s t er R et u r n s :     1 b yt e

1) C on f ir m f la g F F h

The computer sends a serial stop byte #255 (FFh ) to the Site Ma ster. Site Mast er returns a confirm flag

(FFh). The Site Master resumes sweeping, either continuously or singly.

You may also press the “ES CAPE ” key on th e Site Mast er key pad to exit from remote mode (given th at the

serial communicat ion is st ill in sync). In t his case, the Site Ma ster does not return a confirm byte t o the se-

rial port .

W h e n ex i t i n g r em o t e m o d e , sy st e m p a r a m et e r s c h a n g ed d u r i n g r em o t e m o d e a r e u s ed i m m ed i a t el y.

S yst e m p a r a m e t er s c h a n g ed d u r i n g r em o t e m o d e a r e n o t w r i t t en t o t h e n o n -v o l a t i l e E E P R O M . Yo u  

m a y w a n t t o sa v e t h e ch a n g e t o t h e r u n -t i m e set u p ( s a v ed s et u p l o ca t i o n 0 , w h i c h h o l d s t h e  

p o w e r -o n d ef a u l t s ) o r o n e o f t h e n i n e sa v e d s et u p s ( sa v e d s et u p l o c a t i o n 1 - 9) . S ee co n t r o l b y t e #1 8  

( 1 2h ) f o r d et a i l s.

S113B, S114B, S331B, S332B PM 41

8/12/2019 Site Master B Series Programming Manual

http://slidepdf.com/reader/full/site-master-b-series-programming-manual 48/49

Parameter Definitions

42 S113B, S114B, S331B, S332B PM

Parameter # of Bytes Step Example / Description

Frequency   4 bytes unsigned 1 Hz 1000.3 MHz = 1000300000

Scale (RL, CL)   2 bytes unsigned 1 / 1000 dB 51.3 dB = 51300

(SWR)   2 bytes unsigned 1 / 1000 (ratio) 65.53 = 65530

(SPA) (dB/div)   4 bytes unsigned 1 / 1000 dB 8 dB + 8000

(SPA) (ref level)   4 bytes unsigned 1 / 1000 + 270,000 20 dB = 20,000 + 270,000 = 290,000

Limit (RL, CL)   2 bytes unsigned 1 / 1000 dB 51.3 dB = 51300

(SWR)   2 bytes unsigned 1 / 1000 (ratio) 65.53 = 65530

(G/IL)   2 bytes unsigned 1 / 100 dB 100 dB = 0

120 dB = 22000

Markers

(Frequency &

Distance Marker)

2 bytes unsigned 1 sweep point Marker values are given in relative position on the

graph.

The lowest value is 0; the highest value is the number

of data points – 1. Spectrum Analyzer maximum is 399.

Distance   4 bytes unsigned 1 / 100,000 m/ft 12.34 m = 1234000

Relative

Propagation

Velocity

4 bytes unsigned 1 / 100,000 0.837 = 83700

Cable Loss   4 bytes unsigned 1 / 100,000 dB -0.345 dB/m = 34500

Gamma   4 bytes signed 1 / 1000 (ratio) Gamma value is the ratio of magnitude of reflected

signal over the magnitude of incident signal.

Phase   4 bytes signed 1 / 10 degree Phase value is the difference in phase between the

incident and reflected signal.

Power Monitor:

dBm/dBr

4 bytes signed 1 / 1000 dBm

1 / 1000 dBr

51.3 dBm = 51300

10.4 dBr = 10400

Lock Fail

Counter

2 bytes unsigned 1 error count 234 fails = 234

Integrator Fail

Counter

2 bytes unsigned 1 error count 123 fails = 123