HUAWEI TECHNOLOGIES CO., LTD.
DBS3900 WiMAX
V100R002C00
Quick Installation Guide
(Co-RRU3232)
Issue: Draft ADate: 2012-05-15
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 2/391
Contents
Installation Tools
Installation Scenarios
Requirements for Dimensions and Installation
Space
Installation Flowchart
Install ing a BBU3900
Installing an RRU
Cable ConnectionsInstall ing BBU3900 Cables
Install ing RRU Cables
Installing an Outdoor Junction Box
Measuring the VSWR of the Antenna System
Installation Checklist for the BBU
Installation Checklist for the RRU
Checklist for the Project Implementation
Appendix
2
3
4
6
7
9
1519
26
30
30
31
32
32
33
Copyright © Huawei Technologies Co., Ltd. 2012. All rights reserved.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 3/392
Installation Tools
Phillips screwdriver (M3 to M6)
Flat-head screwdriver (M3 to M6)
Adjustable wrench
(aperture ≥ 32 mm or 1 1/4")
Torque screwdriver
Measuring tape
Vacuum cleaner
Wire stripper
Level
Marker
(diameter ≤ 10 mm or 0 3/8")Multimeter
Rubber mallet
ESD gloves
Combination wrench21 mm to 21 mm (0 13/16" to0 13/16") for the pole-mounted mode
17 mm to 17 mm (0 11/16" to0 11/16") for the wall-mounted mode
Cable cutter
Heat gun
Hammer drill (Bit Ф14)
Utility knife
Torque wrench
COAX crimping tool
5 mm (0 3/16")
M3 to M6
Inner hexagon spanner
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 4/393
Installation Scenarios
a
b RRU3232 Installation
BBU3900 Installation
In a 19-inch cabinet In an APM30 In a TMC11H In an OMB
For details about how to install an APM30 and TMC11H, see the APM30H Installation Guide.
On the wall
BBU
On a wire pole
BBU
On a pole On U-steelOn angle steel
• A cabinet must be powered on within 24 hours after it is unpacked, and the power-off time for maintenance
must not exceed 48 hours to avoid short circuits.• A module must be powered on within 24 hours after it is unpacked, and the power-off time for maintenancemust not exceed 24 hours to avoid short circuits.
BBU
BBU
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 5/394
Requirements for Dimensions and Installation Space
a Dimensions
Dimensions of an RRU with a shell (H x W x D):485 mm x 300 mm x 170 mm (1'-7 1/8" x 11 13/16" x 6 11/16")
Dimensions of a BBU (H x W x D):
86 mm x 442 mm x 310 mm (3 3/8" x 1'-5 3/8" x 1'-0 3/16")
310 mm (1'-0 3/16")
442 mm (1'-5 3/8")
86 mm (3 3/8")
Space Requirements for Installing a BBU3900
Space that is required on three sides of a 19-inch cabinet for installing a BBU3900
25 mm (0 1")
25 mm (0 1")
70 mm (2 3/4")
b
485 mm (1'-7 1/8")
300 mm (11 13/16") 170 mm (6 11/16")
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 6/395
Space Requirements for Installing an RRU3232c
≥ 300 mm (11 13/16")
≥ 500 mm (1'-7 11/16")
≥ 8 0 0
m m
( 2 ' - 7 1
/ 2 " )≥ 6 0 0 m m ( 1 ' - 1 1 5 / 8 " )
≥ 3 0 0 m m ( 1 1 1
3 / 1 6 " )
200 mm (7 7/8")
300 mm (11 13/16")
6 0 0 m
m
( 1 ' - 1 1
5 / 8 " )
4 0 0 m m ( 1 ' - 3 3 / 4 " )
1 0 0 m m
( 3 1 5 / 1 6 " )
Recommended space Minimum space
The minimum installation space meets the requirements ofthe equipment for normal running and heat dissipation, butdoes not meet the requirements for OM such as checkingthe indicator status and opening the maintenance cavity.When the ambient space is insufficient, the minimuminstallation space can be adopted.
The recommended installation space meets therequirements of the equipment for normal runningand OM. When the ambient space is sufficient, therecommended installation space can be adopted.
Recommended horizontal distancebetween two RRUs Minimum horizontal distance between two RRUs
Recommended vertical distance betweentwo RRUs
Minimum vertical distance between two RRUs
≥ 500 mm (1'-7 11/16")
≥ 500 mm (1'-7 11/16")
≥ 300 mm (11 13/16")
300 mm (11 13/16")
300 mm (11 13/16")
200 mm (7 7/8")
≥ 300 mm(11 13/16")
≥ 600 mm(1'-11 5/8")
≥ 600 mm(1'-11 5/8") 100 mm
(3 15/16")
400 mm(1'-3 3/4")
400 mm(1'-3 3/4")
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 7/396
Installation Flowchart
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 8/397
Installing a BBU3900
a Installing a BBU3900 in a 19-Inch Rack
b Installing a BBU3900 in an APM30H
BBU
Mounting ears in
reverse mode
Mounting ears instandard mode
2 N·m
(17.70 lbf·in.)
M6X16
2 N·m
(17.70 lbf·in.)
M6x16
a. Verify that the BBU3900 mounting ears in a 19-inch rack oran OMB are installed in standard mode, and the BBU3900mounting ears in an APM are installed in reverse mode.
b. Install a BBU3900 in an APM30H usinga binding bracket.
Mounting ears inreverse mode
Mounting ears inreverse modeBindingbracket
Mounting ears instandard mode
For easy installation, remove the two groundscrews from the right side of the BBU3900panel before installing the BBU3900.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 9/398
d Installing the BBU3900 in an OMB
c Installing the BBU3900 in a TMC11H
BBU3900
Reversely installed
mounting ears
FAN
Reversely installedmounting ears
M6X16
2 N.m(17.70 lbf.in.)
M6X16
2 N.m(17.70 lbf.in.)
Remove the two ground screws on the right side of
the BBU panel before installing the BBU.
BBU3900
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 10/399
Dual-nut bolt
Main bracket
Auxiliarybracket
Installing an RRU
RRU mounting kits
a Installing an RRU on a Pole with a Diameter of 60 mm to 114mm (2 3/8'' to 4 1/2'')
• Place the RRU on foam or cardboard for protection.• Do not place the RRU on the ground in the upright position, because the RF ports at the bottom of the RRU
cannot bear the weight of the RRU.
Cover plate Attachmentplate
Confirm that the hoistclamps on the mainbracket are securely
tightened beforeinstalling the mainbracket.
1200 mm to 1600 mm(3'-11 1/4'' to 5'-3'')
Tighten the screws afterinstalling the RRU. Loosenthe screws before
removing the RRU.
1. Install a main bracket.
Fit one end of the auxiliary bracket onto one dual-nut bolt, and then fit the other end onto the other dual-nutbolt during installation.
Fixing hoop
Tighten the screws toremove the RRU.
60 mm to 114 mm (2 3/8'' to 4 1/2'')Recommended diameter of the pole: 80 mm (3 1/8")
Main bracket
Hoistclamp
The anglebetween thevertical line andthe angle steelor U-steel mustbe less than orequal to 10degrees.
≤ 10°
RRU
Anglesteel orU-steel
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 11/3910
Installing Two RRUs on a Pole with a Diameter of 60 mm to114 mm (2 3/8'' to 4 1/2'')b
The arrows onthe main bracketpoint upwards.
2. To secure the main and auxiliary brackets to the pole, tighten the nuts using an adjustablewrench with a torque of 40 N·m (354.03 lbf·in.).
Tighten the two dual-nut bolts alternatively. After thebrackets are secured, use a measuring tape toconfirm that the distances between the main bracketand the auxiliary bracket on both sides are the same.
40 N·m
(354.03 lbf·in.)
3. Install an RRU on the main bracket, and adjust the position of the RRU until it snaps shut.
1. Install one RRU. 2. Install another RRU.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 12/3911
4. Install the second RRU on the main bracket.
3. Swap the front cover plate with the attachment plate at the rear of thesecond RRU.
Ensure that the cablingcavities of the two RRUsface the same directionwhen installing the RRUsin back-to-back mode.
Cable cavity
RRU in standard mode RRU in reverse mode
5 N·m
(44.25 lbf·in.)
M6X16
Top views of fourinstallation modes
c Installing an RRU on U-Steel
50 mm to 100 mm(1 15/16'' to 3 15/16'')
30 mm to 50 mm(1 3/16'' to 1 15/16'')
U-steel
• The procedure for installing the RRUon U-steel is the same as theprocedure for installing the RRU on apole.
• You are advised to install only oneRRU on U-steel.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 13/3912
Top view of the installationmode
d Installing an RRU on Angle Steel
Angle steel6 3 m
m t o 8 0 m
m
( 2 1 / 2 ' ' t o 3
1 / 8 ' ' ) 6 3
m m
t o 8 0 m m
( 2 1 / 2 ' ' t
o 3 1 / 8 ' ' )
You are advised to install only one RRUon a wire pole.
e Installing an RRU on a Wire Pole with a Diameter of 300 mm to390 mm (11 13/16'' to 1' 3 3/8'')
Main bracket
Fixing hoop
35 N·m
(309.78 lbf·in.)
• The procedure for installing the RRU onangle steel is the same as the procedure forinstalling the RRU on a pole.
• You are advised to install only one RRU onangle steel.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 14/3913
f Installing an RRU on the Wall
1200 mm to 1600 mm(3'-11 1/4" to 5'-3")
128 mm(5 1/16")
Auxiliary bracket
RRU
1. Place the auxiliary bracket in the installation position against the wall.Then, level the auxiliary bracket using a level and mark the anchor pointsusing a marker.
The recommended distance between the auxiliary bracket and the floor isfrom 1200 mm to 1600 mm (3'-11 1/4" to 5'-3").
2. Drill holes at the anchor points and then install the expansion bolts.
Ø14
After completely removingan expansion bolt, discardthe plastic tube.
M10x65 bolt
Spring washer 10
Plastic tube
Flat washer 10
Expansion tube
90°55 mm to 60 mm(2 3/16" to 2 3/8")
20 mm to 30 mm(0 13/16" to 1 3/16")
• Do not hammer the boltentirely into the wall.
• Leave 20 mm to 30 mm(0 13/16" to 1 3/16") ofthe bolt outside the wall.
86 mm(3 3/8")
86 mm(3 3/8")
Requirements for installing only one RRU on the wall are as follows:• The wall must bear a minimum of four times the weight of an RRU.
• The torque for tightening the expansion bolt is 30 N·m (265.52 lbf·in.). This ensures that the expansion boltsare secured to the wall without causing damage to it.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 15/3914
3. Fit the auxiliary bracket on the expansionbolts in the downward direction, and thentighten the bolts using a combination wrenchwith a diameter of 17 mm (0 11/16").
4. Install a main bracket.
5. Install an RRU.
The arrows on the mainbracket point upwards.
30 N·m
(265.52 lbf·in.)
M10
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 16/3915
Cable Connections
a Cable Connections for the RRU
RS485 port
Externalpowersupplysystem
Optical fiber
Ethernet cable
To aBooleansensor
Connected through the optical
fiber or Ethernet cable
RRU power cable
CPRI optical fiber
BBU powercable
DCDU
Configuration Type WiMAX: S(2/2/2), 2T2R, 10M Hz
LTE:S(1/1/1), 2T2R, 20M Hz WiMAX LTE
2C 1C
C=carrier,1C=1carrier,2C=2 carrier
A
NT
A
NT
A
NT
A
NT
A
NT
A
NT
Color-coding
ASN-GW
The LMPTb, LMPTw, LBBPc, UPEUc, and FANc are used as examples.
In co-RRU mode, the BBU and the RRU are connected only in a dual-star topology. The RRU is connected to basebandprocessing boards for different modes in the BBU using two CPRI ports.
An LBBPc provides six CPRI ports. However, only the CPRI0, CPRI1, and CPRI2 ports are used in the typical configurationsof a WiMAX-LTE BS in co-RRU mode.
Configure the DCDU based on onsite situations.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 17/3916
DCDU
WiMAX LTE
2C 1C
C=carrier,1C=1carrier,2C=2 carrier
RS485 portOptical fiber
Ethernet cable
To aBoolean
sensor
Connected through the optical
fiber or Ethernet cable
RRU power cable
CPRI optical fiber
BBU power
cable
Configuration Type WiMAX: S(2/2/2), 4T4R, 10M Hz
LTE:S(1/1/1), 4T4R, 10M Hz
ANT
Color-coding
Externalpowersupplysystem
ANT ANT
ASN-GW
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 18/3917
DCDU
WiMAX LTE
1C 1C
C=carrier,1C=1carrier
RRU power cable
BBU powercable
Configuration Type WiMAX: S(1/1/1), 4T4R, 10M Hz
LTE:S(1/1/1), 4T4R, 20M Hz
ANT ANT ANT
CPRI optical fiber
RS485 portTo aBoolean
sensor
Optical fiber
Ethernet cable
Connected through the opticalfiber or Ethernet cable
ASN-GW
External
powersupplysystem
Color-coding
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 19/3918
b Cable Connections for an OMB
OMB PGND cable
FE cable AC input power cable
CPRI optical fiber
Monitoring cable between themonitoring board and the UPEU
BBU input power cable
Monitoring cable between the EPS30-4815 and the monitoring board
Remove the waterproof module before installing the cables. Then,route the cables into the holes at the bottom of the cabinet as
required. After installing all cables, reinstall the waterproof module.
a c
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 20/3919
BBU power cable
• The BBU PGND cable is yellow and green or green, with a
cross-sectional area of 6 mm2 (0.01 in.2).
• One end of the PGND cable is connected to the BBU using an
OT terminal or a two-hole M4 OT terminal, and the other end
of the cable is connected to the ground bar using an OT
terminal. The BBU PGND cable must be prepared onsite.
• The PGND cable in the APM30, TMC, or OMB is groundedusing mounting ears.
Installing BBU3900 Cables
a Installing a PGND Cable
b Installing a -48 V DC Power Cable
BBU PGND cableTwo-hole OTterminal
OTterminal
BBU
BBU
BBU
BBU
DCDU-03B
DCDU
APM30H TMC11H
• Connect the DCDU-03B and the BBU using the LOAD6 or LOAD7 port,with a priority of LOAD6 > LOAD7.• Connect the DCDU-03C and the BBU using the LOAD6 port.
PWR
LOAD6
The following figures showa bent OT terminal.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 21/3920
PWR
LOAD1 10AOMB
d Installing a Power Cable Between the BBU3900 and the TMC11H
e Installing a Power Cable Between the BBU3900 and the OMB
c Installing a Power Cable Between the BBU3900 and the APM30H
PWR
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 22/3921
f Installing an FE/GE Ethernet Cable or Optical Fiber
ASN-GW
Optical fiber Ethernet cable
BBU3900
Ethernet cableOptical fiber
Install swappableoptical modules• Use either the Ethernet cable or optical fiber to connect
the transmission equipment or gateway.• Install swappable optical modules before installing optical
fibers. The performance of an optical module that isexposed to the air for more than 20 minutes may be
abnormal. Therefore, you must insert an fiber optic cableinto an unpacked optical module within 20 minutes.
• Confirm that the FE/GE Ethernet cable is a shieldstraight-through cable.
Ground the shield layer of an FE/GE Ethernet cable if an FE/GE Ethernet cable is used in an APM30H orTMC11H. For details about the grounding, see the description below.
ground clip
Install a ground clip on an FE/GE Ethernet cable at proper positionwithin 1 m (3'-3 3/8") from the cabinet cable outlet.
1. Determine the position for grounding the FE/GE Ethernet cable, and
strip off a sheath of about 40 mm (1 9/16") to expose the shield layer.2. Loosen the screws on the ground clip, and route the FE/GE cable
through the clip.
3. Confirm that the shield layer of the FE/GE Ethernet cable is in fullcontact with the ground clip, and tighten the screws on the clip.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 23/3922
g Install ing CPRI Optical Fibers Between the BBU3900 and the RRU3702
h Installing a GPS Clock Signal Cable
• Install swappable optical modules before installing optical fibers. The performanceof an optical module that is exposed to the air for more than 20 minutes may beabnormal. Therefore, you must insert an fiber optic cable into an unpacked opticalmodule within 20 minutes.• Connect the longer exposed end of the optical fiber to the BBU and wrap the endwith a tube, and connect the shorter exposed end to the RRU.
CPRI optical fiber
Install hot-swappableoptical modules.
• Ground the GPS surge protector if the BBU is installed in a 19 inch cabinet.• If the PGND cable for the GPS surge protector is grounded nearby. If no ground bar is available nearby, connectthe PGND cable to the ground screw for the BBU. Note that two OT terminals can be connected to the ground
screw.• If the cross-sectional area of the PGND cable is 6 mm2 (0.01 in.2), install an OT terminal to each end of thePGND cable.
SMA maleconnector
Type N femaleconnector
GPS clock signal cable
Surge protector
on theequipment side
ProtectSurge
GPS antenna
BBU3900
GPS clocksignal cable
SMA
T-connector
The installation of an SMA T-connector is forreference only.
RRU3232 RRU3232 RRU3232
WiMAXLTE
WiMAX
LTE
WiMAX
LTE
WiMAX
LTE
WiMAX
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 24/3923
b. In an OMB1.Install an SMA T-connector.
2.Install a surge protector.
Surge protector
SMA male connector
• Install a T-connector inside a cabinet andsecure it nearby based on the cable layout.
• Wrap the T-connector joints with PVCinsulation tape.
a. In an APM30H
SMA T-connector
Surge protector
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 25/3924
jInstalling a Monitor ing Signal Cable Between the BBU3900
and the CMUA (APM30H, TMC11H)
APM30H TMC11H
i Installing a Monitor ing Signal Cable Between the BBU3900 andthe EMUA
Monitoring signal cable betweenthe BBU3900 and the EMUA
EMUA
MON1
The cable connection does not
apply to the APM30H, TMC11H,and OMB.
APM30HTMC11H
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 26/3925
kInstalling a Monitor ing Signal Cable Between the BBU3900 andthe OMB
MON1
RS232/RS485
COM OUT COM IN
When an OMB is configured, the COM IN port on the
OMB corresponds to the MON1 port on the BBU, and
the COM OUT port on the OMB corresponds to theRS232/RS485 port on the AC/DC power module.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 27/3926
Installing RRU Cables
a Installing a PGND Cable
RRU PGND cable
• The RRU PGND cable is yellow and green or green, with across-sectional area of 16 mm2 (0.02 in.2 or 6 AWG).
• The two-hole OT terminal (M6) on one end of the cable isconnected to the RRU, and the OT terminal on the other endis connected to the ground bar. The RRU PGND cable mustbe prepared onsite.
Two-hole OTterminal
OT terminal
bb Installing a Power Cable
4.8 N·m(42.48 lbf·in.)
M6
a.RRU+APM30H
An EPS subrack supplies power to amaximum of six RRUs. Therefore, an RRU
power cable can be connected to any of theRRU0 to RRU5 ports on the EPS subrack.
Link the easy power receptacle (pressfit type) connector at one end of the RRU power
cable to the RRU0 port on the EPS subrack.
Grounding the shielding
layer of the power cable:
shielding layer [40 mm (1 9/16“)] PGND cable
(7 7/8")
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 28/3927
RRU power cable
• Connect the DCDU-03B and the RRU using theLOAD0 or LOAD5 port, with a priority of LOAD0> LOAD5.
• When the BBU and RRU are used indoors, donot ground the RRU power cable.
• The RRU power cable must be grounded if anRRU is installed outdoors. For details, see the
appendix.• For details about how to prepare an OT terminal,see the appendix.
Ground
point for theshield layer
of the powercable
DCDU-03B
LOAD0NEG0(-)RTN0(+)
Groundclip
Feederwindow
RRU
b.RRU+TMC11H c.RRU+OMB
• In the 220 V AC single-phase and 110 V AC dual-live-wire power supplyscenario, only one RRU can be installed because the power supply capacityof the power equipment (AC/DC) is limited.• No surge protection is required for DC power supply. In this case, an RRUpower cable can be used for a distance of not greater than 5 m (16'-4 7/8").RRU cable connection
(7 7/8")
Bent OT terminal:
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 29/3928
c Closing the RRU Cabling Cavity
Strictly follow the instructions in the label
and the installation guide when preparingthe cable.
Cover of the cabling cavity
Waterproof block
To prepare the easy power receptacle (pressfittype) female connector for the RRU powercable, perform the following steps:
Label for the RRU
power cable
1.4 N·m
(12.39 lbf·in.)
M4
After installing RRU cables, fill the
vacant cable holes in the cablingcavity using waterproof blocks.
1. Determine the length of different parts based on thelabel on the cover plate of the cabling cavity.
2. Strip the sheath and shield layer as required.
3. Strip the sheath of each core.
4. Install an easy power receptacle (pressfit type)female connector to both ends of the two cores.
a. Push the yellow module using a Flat-head screwdriver.
b. Securely connect the blue NEG(-) wire to the 2 or - port on theconnector, and black or brown RTN(+) wire to the 1 or + port on
the connector. Then, push the exposed yellow module back.
5. Strip the sheath of the RRU power cable asrequired to expose the shield layer.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 30/3929
d Installing RF Jumpers
Wrap a layer of PVCinsulation tape.
Wrap three layers ofwaterproof tape.
Wrap three layers of PVCinsulation tape.
Measure the VSWR of the antenna system before installingan RF jumper. For details, see "Measuring the VSWR of the Antenna System" on page 30.
RF jumper
Take insulation and waterproof measures only for outdoorRF jumpers.
2. Wrap PVC insulation tape.
1. Install RF jumpers.
Waterproof tape
Dustproofcap
Insulating tape
Keep the dustproof caps on vacant feeder connectors. Wrap thefeeder connectors with waterproof tapes for outdoor scenarios, asshown in the figure.
Insulating tape
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 31/3930
Measuring the VSWR of the Antenna System
Measure the VSWR of the antenna system using aBroadband Site Master.
Measure the VSWR at the point where the antenna
system is connected to the RF port on the RRU. Connect
the antenna system to the RF port on the RRU only
when the VSWR of the antenna system is lower than 1.5.
Do not connect the antenna system to theRRU if the VSWR of the antenna system ishigher than or equal to 1.5.
Installing an Outdoor Junction Box
RTN(+)
• When the distance between the RRU3232 and the APM30H ranges from 60 m (196'-10 3/16'') to180 m (590'-6 5/8''), install an outdoor junction box on the RRU side.
• Confirm that the cross-sectional area of the power cable between the outdoor junction box and theDCDU or APM30H is 10 mm2 (0.02 in.2 or 7 AWG).
• Confirm that the cross-sectional area of the power cable between the outdoor junction box and theRRU is 3.3 mm2 (0.01 in.2 or 12 AWG), and the length of the cable ranges from 3 m (9'-10 1/8") to5 m (16'-4 3/4'').
Grounding
Connected to anRRU3232
Connected to
-48 V DC power
NEG(-)
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 32/3931
No. Item
1 All self-made PGND cables are copper-based and are of the correct wire
diameters. No breaking devices, such as switches and fuses, are allowed for
the electric connection of the grounding system. No short circuits are allowed.Each terminal on the ground bar connects to only one wiring terminal of thePGND cable.
2 The redundant part of the power cable or PGND cable is stripped off.
3 The terminals at both ends of the power cable or PGND cable are securelysoldered or crimped.
4 The bare wires and the terminal handles of the wiring terminals are coated withheat shrink tubings.
5 The flat washer and the spring washer are securely mounted on all OTterminals.
6 All cables, especially those at the bottom of the cabinet, are securelyconnected.
7 All cables are neatly and tightly bound. The cable ties are evenly spaced andface the same direction.
8 The power cable, PGND cable, feeder, optical fiber, and E1/T1/FE signal cableare bound separately with a minimum spacing of 3 cm (1 3/16").
9 The cable layout facilitates future maintenance and capacity expansion, andthe cable radii meet the requirements.
10 Labels at both ends of a cable are legible.
11 The extra length of the cable ties is cut and removed. The cut surfaces aresmooth and have no sharp edges.
12 The vacant connectors for the cables are properly protected.
Installation Checklist for the BBU
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 33/39
Upgrade the software and deliverthe configuration using a USB
disk
Start the project self-test functionon the Web LMT
Save the report
End
Is the test successful? Power off the BS and check thehardware installation
Start
Power on the BS
Prepare a USB disk
Yes
No
Power on the BS
32
No. Item
1 The RRU and its mounting kits are securely installed.
2 The cover plate is securely installed on the RRU cabling cavity.
3 Waterproof blocks are installed in vacant cable troughs of the RRU cablingcavity. The cover plate of the cabling cavity is securely installed. The vacantRF ports are waterproofed and covered with waterproof caps.
4 The power cable and PGND cable are intact.
5 The terminals at both ends of the power cable or PGND cable are securelysoldered or crimped.
6 The flat washer and the spring washer are securely mounted on all OTterminals.
7 The power cable and the PGND cable are intact and correctly connected.They are not short-circuited.
8 The power cable, PGND cable, feeder, optical fiber, and E1/T1/FE signalcable are bound separately with a minimum spacing of 3 cm (1 3/16").
9 The signal cables are not damaged or broken, and the connectors are intact.
10 Labels at both ends of each cable are correct, legible, and complete.
Installation Checklist for the RRU
Checklist for the Project Implementation
Perform a self-checkafter the project iscomplete.
For details about the procedures, see
the online help after logging in to theWeb LMT.
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 34/3933
Appendix
Hoist the RRU3232 and mount ing k its onto a tower.
Bind the RRU and the mounting kits using a sling.
• Protect the RRU from colliding with the tower whenhoisting it.
• Ensure that the diameters for the lifting sling and tractionsling are about 20 mm (0 13/16'') and are less than 25 mm(0 1").
• Ensure that the ropes bear a weight more than four timesthe weight of an RRU.
• Installation engineer A climbs the tower, secures a fixedpulley to the support on the tower platform, and then
inserts a lifting sling through the fixed pulley.• Installation engineer C ties the RRU and mounting kits
using the lifting sling following the instructions in thefigure, and then ties a knot at the RRU handle using atraction sling.
• Installation engineer B pulls down the lifting sling.Installation engineer C pulls out the traction sling toprevent the RRU and the mounting kits from collidingwith the tower.
• Installation engineer A holds on to the RRU and themounting kits, and then loosens the knot to release theitems.
• The previous hoisting method is for reference only.
Do not lift the RRU by thehandle only.
Lifting sling
Lower edge of theattachment plate
Traction sling
Fixed pulley
Tractionsling
Lifting sling
Hoisting the RRU3232 and Mounting Kits onto a Tower a
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 35/3934
Indicator b
a
b
Indicators on the BBU LMPT
Indicators at CPRI ports on the BBU LBBP
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 36/3935
c Indicators on the RRU3232
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 37/39
Preparing OT Terminals for a DCDU Power Cabled
Lead the wires
made of the
shielding layers
through heat-
shrinkable tubes.
Wrap the PVCinsulating tape
at the joint
where the three
wires meet.OT terminal on
the shielding
layer
36
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En
http://slidepdf.com/reader/full/singleran-wimax-lte-quick-installation-guideco-rru3232v100r002c00draft 38/39
Installing a Ground Clipe
Wrap three layers of tape following the sequence shown in the above figures. When wrapping tape, be surethat each layer of tape overlaps more than 50% of the preceding layer.
The other end of the ground cable connecting to the ground clip is terminated with a one-hole OT terminal withan M8 bolt, and is connected to an external ground bar.
1. Strip a sheath of 32 mm (1 1/4" ) from an RRU power cable using a wire stripper.
2. Install a ground clip on the exposed shield layer, and tighten the screws on the
ground clip.
• Ensure that the exposed shield layer must be longer than a ground clip.
• Do not clip the shield layer of an RRU power cable to a ground clip.
4. Wrap the ground clip using PVC
insulation tape.
3. Wrap the ground clip us ing
waterproof tape.
Groundcable
Ground clip
RRU powercable
37
7/18/2019 SingleRAN WiMAX-LTE Quick Installation Guide(Co-RRU3232)(V100R002C00_Draft a)(PDF)-En