Single Pole and 3-Way Wide View Motion Activated Light ControlCat. No. IPS15, IPV15 - INDOOR USE ONLY
120VAC, 60Hz - Incandescent: 1800W-15A - Fluorescent: 1800VA-15A - Supplemental: 1/2HP - LED & CFL: 600WCompatible with incandescent lamps, magnetic fluorescent ballasts, fans, CFL and LED lamps.
INSTALLATION INSTRUCTIONSWARNINGS AND CAUTIONS:• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!• Tobeinstalledand/orusedinaccordancewithelectricalcodesandregulations.• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,DO NOT install to control a receptacle.• DO NOT control a load in excess of specified ratings or you may damage property, or cause injury or death.• Ifyouarenotsureaboutanypartoftheseinstructions,consultanelectrician.
WARNINGS AND CAUTIONS:• Whenusingina3-wayormoreapplicationuseappropriatematchingorcoordinatingswitchremote(s).• Cleanoutersurfacegentlywithdampclothonly.DO NOT usesoapsorcleaningliquids.• Nouserserviceablecomponents.DO NOT attempttoserviceorrepair.• UsethisdeviceWITH COPPER OR COPPER CLAD WIRE ONLY.
WIRING SENSOR:Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal screw.• Line Hot wall box wire to terminal screw marked "BK".• Load wall box wire to terminal screw marked "RD".• LineNeutralwallboxwiretoterminalscrewmarked"WH".• Terminalscrewmarked"3-Way"shouldhaveRedinsulationlabel
affixed.NOTE: If insulating label is not affixed to terminal screw marked "3-Way",useelectricaltapetocover.
• ProceedtoStep5.
Hot (Black)
Neutral (White)
Load
BKWH
Sensor
Black
White
RD
GreenGround
3-Way Line 120 VAC, 60Hz
Use Terminal for 3-Way Applications Only.For Single Pole Applications,Do Not Remove This Label.
BK WH
RD3-Way
4
1
3
2
Terminal Screw Marked White (WH)
Sensor
TerminalScrew marked
Red (RD)
TerminalScrew marked
Black (BK)
BrassTerminal Screw
Marked 3-Way
Terminal Label:Use Terminal for 3-Way Applications Only.For Single Pole Applications, Do Not Remove This Label.
Ground(Green Screw)
PK-93977-10-00-2A
GreenGround
Hot (Black)
Neutral (White)
YL/RD 3-WayRD
WH
RD
BK
Black
BKWH
White
Line 120VAC, 60Hz
GreenGround
(unused)
(unused)
Load
SensorVP0SR-10 Remote
2BK WH
RD3-Way
Sensor
3
5
1
4
21
4
VP0SR-10 Remote
TerminalScrew marked
Black (BK)
TerminalScrew marked
Red (RD)
Brass TerminalScrew marked
3-Way
TerminalScrew marked
White (WH)
BK
RDYL/RD
WH
3
5
Ground TerminalScrew (Green)
3-Way Wiring with ViziaTM Coordinating Remote (no LED) Application: Step 4
WIRING SENSOR:Connect wires per WIRING DIAGRAM as follows:NOTE:ThesensormustbeinstalledinawallboxthathasaLineHotconnection.NOTE:Maximumwirelengthfromsensortoremotecannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremovingoldswitchto
terminal screw marked "BK".• FirstTravelerwallboxwiretoterminalscrewmarked"RD"(note wire color).• RemoveRedinsulatinglabelfromterminalscrewmarked"3-Way".• SecondTravelerwallboxwiretoterminalscrewmarked"3-Way"(note wire color).
Thistravelerfromthesensormustgototheterminalscrewontheremotemarked"YL/RD".
• Neutralwallboxwiretoterminalscrewmarked"WH".
WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows:NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tightenbothscrews.NOTE:Maximumwirelengthfromsensortoremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoFirstTraveler
(note color as above).• SecondTravelerwallboxwire(note color as above) to terminal screw marked
"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewonthesensormarked"3-Way".
• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".• Neutralwallboxwiretoterminalscrewmarked"WH".• Proceed to Step 5.
TOOLS NEEDED TO INSTALL YOUR DEVICE
CHANGING THE COLOR OF YOUR DEVICE
Push down tabs per diagram, one at a time and rotate forward to release
RESETRESET
TESTTEST
1 2
0 31 2
0 3
1 2
0 3
Attach new face by inserting bottom hinge tabs, then pivot and snap the color kit to attach
Yourdevicemayincludecoloroptions.Tochangecolorofthefaceproceed as follows:
INSTALLING YOUR DEVICE
NOTE: Use check boxes when Steps are completed.√
FEATURES• Cat.No.IPS15andIPV15haveasensingareaofcoverageof
30ft.x30ft.,andasensingangleof180O (see Sensing Area Coverage figure on page 2).
• Adjustablelightandtime-delaycontrolsarelocatedonthefrontofthedevice.Seeadjustmentsettingsectiononpage2fordetails.
• LEDindicatorisusedtoalerttheuserofthestatusofthedevice.• AdjustableTimeDelaysettingfor30seconds,5minutes,15minutes
and30minutes.
DESCRIPTIONTheIPV15,whichfeaturesaManual-ONoperation,isCaliforniaTitle242005compliant.Theunitturnsoffmanuallyorinabsenceofmotionaccordingtothetimeoutselected.TheIPS15providesAutomatic-ON/OFFoperationaswellasManual-OFFwiththepushpad.Theseunitsinstallinplaceofasingle-poleor3-waywallswitchandfitinastandardwallbox.Theseunitscanbeusedforswitchingincandescentlamps,magneticfluorescent ballasts, fans, CFL and LED lamps.
LOCATION / MOUNTINGThedevicerespondstotemperaturechangesandcareshouldbetakenwhenmountingthedevice.DO NOTmountdirectlyaboveaheatsource,in a location where hot or cold drafts will blow directly on the sensor, or whereunintendedmotion(e.g.,hallwaytraffic)willbewithinsensor’sfield-of-view.
Slotted/PhillipsScrewdriver ElectricalTape PliersPencil Cutters Ruler
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Step 1 WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
IMPORTANT:For3-Wayapplications,notethatoneofthescrewterminalsfromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthecommon(LineorLoad)inboththesensorwallboxandremotewallbox.
Step 2 Identifying your wiring application (most common):NOTE: If the wiring in the wall box does not resemble any of these configurations, consult an electrician.
2
4
1
5
3
3-Way1. Line or Load
(See important note below)
2. Neutral3. Ground4. FirstTraveler
– note color5. SecondTraveler
– note color
2
4
3
1
Single-Pole1. Line(Hot)2. Neutral3. Ground4. Load
Preparing and connecting wires:Thisdevicecanbewiredusingsidewireterminalscrewsor backwire openings. Choose appropriate wire stripping specifications accordingly.
• Makesurethattheendsofthewiresfromthewallboxarestraight (cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.• For Single Pole Application, go to Step 4a.• For 3-Way Wiring with ViziaTM Coordinating Remote (no LED)
Strip Gage (measure bare wire here or use gage on back of the sensor)
5/8”(1.6 cm)
Cut(if necessary)
Step 3
Side WireSide wire terminals accept #14-12 AWG solid copper wire only.
Back Wire Back wire openings use #14-12 AWG solid copper wire only.
BK
RDYL 3-Way
Single Pole Wiring Application: Step 4
A
B
LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747.This warranty excludes and there is disclaimed liability forlabor for removal of this product or reinstallation.This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Application, go to Step 4b.• For 3-Way Wiring with IPV0R Sensor Remote or ViziaTM Matching
Remote (w/LED) Application, go to Step 4c.
•Positionallwirestoprovideroominoutletwallboxfordevice.
•Ensurethattheword"TOP"isfacingupondevicestrap.
•Partially screw in mounting screws in wall box mounting holes.
•Removethefacecoverofthesensortoexposethe adjustment dials (refer to Changing the Color of your Device on page 1).
•Settimeselectionofthesensorto30secondsforaquicktimeoutduringtesting(Refer to ADJUSTMENT SETTINGS section).
•Setthelightleveldialfullclockwise(Refer to ADJUSTMENT SETTINGS section).
•Placethefacecoverbackonthesensor.•Restorepoweratcircuitbreakerorfuse.•ForIPS15lightswillautomaticallyturnonafterpowerisapplied.•ForIPV15,pressandreleasepushpadtoturnthelightsON. NOTE: See Locator Light Status chart to confirm the operational state of
thedevice.IflightsstilldonotturnON,refertotheTROUBLESHOOTINGsection.
•Leavetheroomorfieldofviewtoallowthesensortotimeoutandshutoffthe lights due to absence of motion.
•Within30secondsofthelightstimingoutstepbackintotheroomorthefieldofviewofthesensorandthelightsshouldturnbackonautomatically.
•Ifthelightsdonotturnoff30secondsafterleavingtheroomdecreasethesensitivityofthesensor(refer to the ADJUSTMENT SETTING section).
•Ifthelightstonotturnbackonautomaticallywhenyoustepbackintotheroomincreasethesensitivityofthesensor(refer to the ADJUSTMENT SETTING section).
•Settimeselectionandlightlevel(Refer to ADJUSTMENT SETTINGS section).
•Whenthedesiredlightlevel(IPS15 only),timeselectionandsensitivitysettingsareselectedplacethefacecoverbackonthesensorandcontinue to Step 6.
Restore Power: Restore power at circuit breaker or fuse.Installation is complete.
Step 7
Device Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 6
Installation may now be completed by tightening mounting screws into wall box. Attach wallplate.
Testing your Device prior to mounting in wall box: Step 5NOTE: Dress wires with a bend as shown in diagram in order torelievestresswhenmountingdevice.
ADJUSTMENT SETTINGSNOTE: Toavoid PERMANENT DAMAGE to the unit, be careful NOT TO OVERTURN the adjustment dials when setting the Sensor.1. Withpowerrestoredandwallplateremoved,removefaceofdevicetoexpose
adjustment dials (refer to Changing the Color of your Device on page 1). Useasmallscrewdrivertoadjustthelightlevel,timeselectionandsensitivityonthedeviceasfollows (Refer to Diagram):
Light Level Adjustment (IPS15 only):•Adjustthelightleveldialclockwise.LightswillturnONinlighterconditions.•Adjustthelightleveldialcounterclockwise.LightswillturnONinlesslighting
conditions.Time Selection:•Adjustthetimeselectordialtothedesiredlengthoftimethelightsareto
remainON.LightswillremainONfrom30secondsto30minutesaftertheroomisvacated.
•AdjustthetimeselectordialclockwisetoincreasethedurationoftheONtimeupto30minutes.
•AdjustthetimeselectordialcounterclockwisetodecreasethedurationoftheONtimedownto30sec.
Sensitivity:•Increaseordecreasethesensitivityofthesensorasfollows.•Todecreasesensitivityanddetectionrange,rotatethedialcounter-clockwise.
Toincreasethesensitivityanddetectionrange,rotatethedialclockwise.Withthearrowpointingat3thesensitivityisfull.Withthearrowpointingat0,thesensitivityisreducedbyhalf.Asthedialrotatesfrom2to0,thechangeinsensitivityismadeinfinesteps.
2. Attachthefacecoverandtestthatthelightlevel,timeselectionandsensitivityaresetasdesired.Ifnot,repeatadjustmentsuntilsatisfied.
For additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at www.leviton.com
ThisproductiscoveredbyU.S.Pat.No.7,924,155 and corresponding foreign patents.
©2012LevitonManufacturingCo.,Inc.AllRightsIncludingTradeDressRightsReserved
TROUBLESHOOTINGLights do not switch ON - IPS15:• Motionisbeyondsensingrange,moveclosertoswitch.• Adjustthelightleveladjustmenttowardlighterordarker,dependingon
room conditions.Lights always stay ON:• ChecktimedelaysettingsandcomparetohowlongthelightsstayON.• Besurethatnomotionoccursincoverageareafortimeselected.• Checkthatswitchisnotinstallednearaheatsource(e.g.,stove,lights,
heatvents)ordetectingmotionfromanadjacentarea(e.g.,hallwaytraffic).Ifso,switchmayhavetoberelocated.
• TryloweringtheSensitivityAdjustmentControl.Rotatetheknobcounterclockwiseabout30°.Iftheproblempersists,tryreducingagain.
NOTE: DO NOT reduce so much that the sensor cannot see normal occupancy.
Lights do not turn ON with the pushpad - IPV15:• Checkthatswitchisinstalledcorrectly.• CheckthatpowerisON.• Checkthatlightbulbisfunctioning.NOTE: If problems continue, consult an electrician.
FCC COMPLIANCE STATEMENTThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttofollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperationofthedevice.ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordance with the instructions, may cause harmful interference to radio communications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrect the interference by one or more of the following measures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthereceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthatto
whichthereceiverisconnected.• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.FCC CAUTIONAnychangesormodificationsnotexpresslyapprovedbyLevitonManufacturingCo.,Inc.,couldvoidtheuser'sauthoritytooperatetheequipment.
LOCATOR LIGHT STATUS
LOAD IPS15 IPV15
OFF Blinking Lit
ON Blinking Blinking
Lens
Push Pad
Locator Light
Side (Vertical) Field-of-View
SENSING AREA COVERAGEField-of-View (Horizontal)
30ft9.1m
30ft9.1m
6ft1.7m
1.8m6ft
30ft9.1m
8.4m27ft
2.1m7ft
1.2m4ft
2.6m8ft
Light Level Adjustment
SensitivityAdjustment
TimeSelection
1 2
0 3
1 2
0 3
1 2
0 3
Settings0123
Time30sec5 min15 min30min
PK-93977-10-00-2A©2012LevitonMfg.Co.,Inc.
NOTE:TheOccupancysensormust be installed in a wall box that hasaLoadconnection.TheSensorremotemust be installed in a wallboxwithaLineHotconnectionandaNeutralconnection.ANeutralwiretotheremoteneedstobeaddedasshown.Ifyouareunsure about any part of these instructions, consult an electrician. NOTE: Maximum wire length from sensor to all installed remotes cannotexceed300ft(90m).
WIRING REMOTE (wall box with Line Hot connection):Connect wires per WIRING DIAGRAM as follows:•GreenorbarecopperwireinwallboxtoGreenterminalscrew.•LineHot(common)wallboxwireidentified(tagged)when
removingoldswitchandFirstTravelertosensorterminalscrewmarked "BK".
•SecondTravelerwallboxwirefromsensortoremoteterminalscrewmarked"3-Way"(note wire color).Thistravelerfromtheremotemustgototheterminalscrewonthesensormarked"3-Way".
•Neutralwallboxwiretoremoteterminalscrewmarked"WH".
WIRING SENSOR (wall box with Load connection):Connect wires per WIRING DIAGRAM as follows:•GreenorbarecopperwireinwallboxtoGreenterminalscrew.•Loadwallboxwireidentified(tagged)whenremovingoldswitchto
terminal screw marked "RD".•FirstTravelerLineHottoterminalscrewmarked"BK".•RemoveRedinsulatinglabelfromterminalscrewmarked"3-Way".•SecondTravelerwallboxwire(note color as above) to terminal
screwmarked"3-Way".Thistravelerfromthesensormustgototheterminalscrewontheremotemarked"3-Way".
•Neutralwallboxwiretoremoteterminalscrewmarked"WH".•ProceedtoStep5.
3-Way Wiring with Sensor Remote or ViziaTM Matching Remote (w/LED) Application: NOTE: IPV0R sensor remote is depicted.
AdditionalNeutral Wire
TerminalScrew marked
Black (BK)
Brass TerminalScrew marked
3-Way
BK WH
RD3-Way
35
14
2BK WH
RD3-Way
3
2
1
4
5
TerminalScrew marked
Red (RD)
TerminalScrew marked
White (WH)SensorIPV0R/VP0SR-1L Remote
GroundTerminal Screw
(Green)
Hot (Bla c k )
Neutral (White)
Sensor IPV0R/VP0SR-1L Remote
3-Way RD 3-Way
WH BK BK
Bla c k
White
Line 120 V A C , 60H z
WH
Load
Green Ground
Green Ground
C OPERATIONIPS15Auto ON: LightswillautomaticallyturnONwhenroomisoccupiedormotionisdetected.TheIPS15willswitchlightsOFFwhennomotionisdetectedinun-occupied room after set period of time.Time delay adjustment: Refer to section on Adjustment Settings.Manual ON:TheIPS15willmanuallyturn-onlightsortheloadbydepressingthepushpadonthedevice.TheIPS15canbesettoonlyturnONbythepushpad(noautomaticonoperation)byadjustingtheambientlightcontroltothe "0" position.IPV15Manual ON: TheIPV15requirestheusertomanuallyturnONlightsortheloadby depressing the push padonthedevice.Thelightsorloadwillautomaticallyturn-off when the room is left unoccupied for a set period of time.Time delay adjustment: Refer to section on Adjustment Settings.NOTE: Ina3-wayapplication,usingviziaTM matching or coordinating remotes, theremotewillonlyhavetheabilitytomanuallyswitchtheloadON,thesensorwillthentimeoutandswitchtheloadOFFoncemotionisnolongerdetected.For automatic control at both locations, use IPV0R as the remote.Locator Light LED:IPS15:LEDblinkswhenmotionisdetectedandiftheloadisONorOFF.IPV15: LEDblinkswhenmotionisdetectedandwhenloadisON.LEDwillremainilluminatedwhenloadisOFF.