Catalog No.:Measurement & Control V8 Feb. 2010
HEAD OFFICE & FACTORY #1559-3, SONGJUNG-DONG, GANGSEO-GU, BUSAN, KOREATEL:+82-51-831-1010, FAX:+82-51-831-1399http : / /www.worldpanasia.comE-mail : [email protected]
SALES CENTERTEL:+82-51-970-1513, E-mail : [email protected]
BRANCH OFFICE IN CHINARm 2907, 317 Xianxia Rd, ShanghaiTEL:+86-21-6235-1601~2 (Ext.8002)
Room 6, 29/F, Rm.04-05 Teemtower, Teemall, 208 Tianhe Road, Tianhe District, Guangzhou, ChinaTel : +86-20-2208-1920
C & C PANASIA1069 Shary Circle, Suite A, Concord, California, U.S.ATel : +1-925-265-1003~4
R&D CENTERTEL:+82-51-970-1537, E-mail : [email protected]
DESIGN CENTERTEL:+82-51-970-1526, E-mail : [email protected]
SERVICE CENTERTEL:+82-51-970-1545, E-mail : [email protected]
GIMHAE FACTORY / E&C DIVISION#715-1, YONGDUK-RI, HANLIM-MYUN, GIMHAE-SI, GYEONGNAM, KOREATEL:+82-55-310-3300, FAX:+82-55-343-3318E-mail : [email protected]
HEAD OFFICE & FACTORY
GIMHAE FACTORY
BALLAST WATER MANAGEMENT SYSTEM
MEASUREMENTand CONTROLF o r S h i p b u i l d i n g & O f f s h o r e
2 3PANASIA CO..,LTD.
Company Profile
COMPANY PERSPECTIVE
Since established in 1989, 20 Years of Experience, Partnership & Performance
2 0 0 0 ~ P r e s e n tAug. 2009 Acquired NET (New Excellent Technology) CertificateJun. 2009 Renewed ISO 9001/2008 & Certified ISO 14001/2004Feb. 2009 Constructed 2nd plant for Environment & Control division at Kimhae city.Dec. 2008 Submitted an application for Final Approval of GloEn-Patrol Ballast Water Treatment Sys. to IMO MEPC 59 SessionMar. 2008 Granted Basic Approval of GloEn-Patrol Ballast Water Treatment Sys. from IMO MEPC 57 sessionJan. 2007 Changed company name to PANASIA CO., LtdJ u l . 2006 Contracted a high efficient DeNox System for IST project in New YorkJun. 2005 Collaborated the technical & marketing division with Endress+Hauser Korea Co., Ltd Jun. 2004 UL certified for Level switch(PR-30 series) & Level transmitter(CPR-100)Dec. 2003 Appointed as INNO-BIZ factory from the GovernmentJun. 2003 Appointed as a promising exporting company from Export Assistance Center.May. 2003 Achieved ISO 9001:2000 certificate(DNV).Sep. 2002 Appointed as Clean Factory from Ministry of Labor.Apr . 2001 Appointed as Superior Exporting firm from Export Assistance Center.Apr . 2001 Awarded the prize from the Minister of Science and Technology.Sep. 2000 Moved to New Factory in Nok-San Industrial Complex.
1 9 8 9 ~ 1 9 9 9J un. 1999 Opened R & D Laboratory.J un. 1998 Appointed as a promising venture company by Korea Electric Power Corp.J un. 1998 Achieved ISO 9001 certificate (DNV).Mar. 1998 Registered Korea Electric Power Corp. as a supplier for Level Instruments for a nuclear power plant.Nov. 1997 Awarded a prize for "A Proud Korean" by the president of Korea.May. 1997 Appointed as a promising technical developing company from Government.Mar. 1997 Awarded the prize of an excellent technical development from Government. Mar. 1996 Registered as a sub-supplier of STX(Daedong) Shipbuilding Co.,Ltd.Apr . 1993 Appointed as a localizing manufacturer for Level Instrument by the Korean Government.Feb. 1993 Awarded the excellent development prize by Hyundai Heavy Ind.Co.,Ltd.J un. 1992 Concluded the technical & marketing collaboration agreement with IPH MARINE AUTOMATION A/S in DENMARK. Mar. 1990 Registered as a sub-supplier of Hyundai Heavy Ind. Co., Ltd.O c t. 1989 Established PAN-ASIA PRECISION & ENGINEERING Co.,Ltd. as a manufacturer of
Level Instrument in the field of marine industry.
M o r e t h a n 1 0 , 0 0 0 s h i p s
M o r e t h a n 2 0 y e a r s
4 5PANASIA CO..,LTD.
Contents
Hoping your business to be prosperous continuously, we sincerely appreciate yourcooperation and support since its establishment in 1989.Despite many setbacks and hardships over the past eighteen years, We, PANASIA has managed to achieve solid growth by turning crisis into opportunity. And also grown into one of the leading companies in the field of level measurement & control technology of marine engineering.Based on our slogan "Dream & Tomorrow",we have always been motivated by passion and a willingness to take on any challenge to make the future better.We will secure world-class level measurement & control technology of marine engineering and understand changes in the markets and with customers. Through this we will play a role as a global company that has the market knowledge tolead our customers. We will continue making innovations and changes.We ask for your continued interest in PANASIA CO.,LTD and hope you will keep watching our ever-changing company.
The Leader in Measurement & Control Technology
Long Accumulated Know-How andTechnology are sure of satisfying customer s needs.
President Robert SooTae, Lee
PRODUCTION TEAMSERVICE TEAMR & D TEAMDESIGN TEAMMARKETING TEAM
Yours sincerely
Radar Beam Type Cargo Tank Monitoring System Magnetic Float Type Cargo Tank Monitoring SystemMagnetic Float Type High & Overfill Alarm SystemAcoustic Type High & Overfill Alarm SystemValve Remote Control SystemAir Purge Type Tank Level & Draft Gauging SystemElectric Pneumatic Type Tank Level & Draft Gauging SystemElectric Pneumatic Type Tank Level & Draft Gauging System (Level Pride)Electric Pneumatic Type Level Transmitter 1:1 Converter (Pneumatic Tank Level Gauge)Electric Pressure Type Level Transmitter (LEVEL-3000)Water Ingress Alarm SystemPressure Monitoring SystemVapour Emission Control SystemFixed Gas Detection SystemPump Room Bilge High Level Ararm SystemTemperature Monitoring System
Flat Type Glass Level GaugeReflex Type Glass Level GaugeMagnetic Float Type Level GaugeSelf-Powered Contents GaugeDial Type Float Level GaugeFloat Type Level Switch Displacement Type Level SwitchReed Switch Type Float Level SwitchElectric IndicatorDigital IndicatorClass Approvals World Wide Service Network
0812141618202224262830323436384041
424446485052565862636465
6 7PANASIA CO..,LTD.
Tank Monitoring SystemProduct List
01. Cargo monitoring SystemRadar Beam TypeMagnetic Float Type
02. High & Overfill alarm systemMagnetic float typeAcoustic type
03. Valve Remote Control System04. Tank Level & Draft gauging System
Air purge type / Electric pneumatic typeElectric pressure transmitter type
05. Vapor Emission control system06. Fixed gas detection system07. Water ingress alarm system08. Pressure / Temperature monitoring system09. Bilge high level alarm system10. Local level gauge / switch
ApplicationLevel-Radar is used for continuous non-contact levelmeasurement of liquids in Cargo Tanks and Slop Tanks ofCrude oil carrier, Oil & Chemical Carrier.The measurement is not affected by changing media,temperature changes, gas blankets or vapours.
Measuring PrincipleLevel-Radar is a "downward-looking" measuring system,operating based on the time-of-flight method. It measures the distance from the reference point(processconnection)to the product surface.Radar impulses are emitted by an antenna, reflected offthe product surface and received again by the radarsystem.
Principle of Radar-Technology
t
d
Generator Emitter
ReceiverTimer
d=c t2
Radar Beam TypeCargo Tank Monitoring System
8 9PANASIA CO..,LTD.
Technical data Your benefits
Measuring range
Output
Measuring accuracyMeasuring cycle
Product temperaturePressure
Major materialBeam angle
Weight
Up to 35m depending oninstallation, product, surfaceconditions and antenna size
4...20mA, HART PROFIBUS PA,FOUNDATION Fieldbus.
ATEX 1/2 G EEX ia C T6ATEX 1/2 G EEX d[ia] C T6
3mm1sec
-40 to 150from vacuum to 40 bar.1 ” thread DN50(2”)..DN150(6”) flange
Certification
Process connection
SUS316810kg
2-wire technology, low price.a real alternative to differential pressure, floats and displacers. 2-wire technology reduces wiring costs and allows easy implementation into existing systems.Non-Contact measurement:Measurement is almost independent from product properties.Easy on-site operation via menu-driven alphanumeric display.Easy commissioning, documentation and diagnostics via operating Software (ToF Tool)2 frequency ranges-26GHz : No compromises, the right frequency for every application.HART or PROFIBUS PA respectively FOUNDATION Fieldbus protocol.
HAZARDOUS AREA NON-HAZARDOUS AREA
10 11PANASIA CO..,LTD.
Advantage of 2 Frequencies Solution for a narrow and small tanklike Slop tank or Residual tank
ToF Family-CommissioningMulti-line plain text display.Removable display for comfortable operation.Menu-guided operation in national language.Help for parameter setting.
Uniform operation concept.Graphical support and online help (BA, TI,..)Documentation of measuring point incl.envelope curveIntegrated program for tank linearization and curve calculation of channel measurement
Commissioning-easy,fast and safe
Display Tool
mm
-acc
urac
y
~ 6GHzLess effected by turbulentsurface and foamLess effected by condensateand build-up
~26GHzIncreased accuracy.Small beam angleIdeal in small vessels.
Sen
sitiv
ity a
gain
st B
uild
-up,
foam
and
turb
ulen
t sur
face
Size of antenna/beam angle
3
10
+
-+-
Levelflex M FMP40
Measuring Precisely andindependent of temperature,pressure and gas layers
Technical data
Product density and variation of densityTurbulent surfaces or foamWall material of the vesselShape of vessel Obstacles
Process mediaMeasuring range
Output
Liquids and solids35m cable, 4m rodHART, PROFIBUS PA, FF2-wire 4...20mA loop powered,4-wire AC/DC
ATEX 1/2 G,ATEX 1/3 D
-40...+150 (pressure up to 40 bar)
IP68
Temperature
Protection
power supply
Certification
12 13PANASIA CO..,LTD.
Magnetic Float Type Cargo Tank Monitoring System
General
The Tank Monitoring System, named as PATROL system is a magnetic float type tank level gaugefeaturing an all-in-one detector that measures tank level, temperature,vapor pressure, as well as issuingalarm when limits are exceeded.The TANK MONITORING SYSTEM monitors these tank conditions on various display units. Information on ballast tanks, fuel oil tanks and draft gauges, as well as cargo tanks can be comprehensivelyutilized by integrated ship operation control system via a loading computer.
A key feature of the Tank Monitoring System is its ease of handling, because the sensors in the detector areflexible, it can be lifted up by hand without the need to enter tanks, even in the case of cargo tanks of crudeoil Tanker, Product oil Tanker, chemical carrier for repair and maintenance.Likewise, transportation and fitting of the Tank Monitoring System is also simple.For LNG carrier, this magnetic float type tank level gauge is usually provided in W.B.T & Draft gaugesystem and F.O tank level gauge system.
System
HAZARDOUS AREA SAFETY AREA
Local Indicator
Tank Top
ApplicationCrude oilProduct oilChemicalsSea WaterFresh Water
Installation ofBottom Support Cargo Monitoring Console
Level/Temp./I.G.Pressure Transmitter
High & OverfillAlarm Switch
Working Principle
Sets of reed switches are positioned along thelength of the guide pipe.As the float travels up and down the guidepipe in accordance with the level of the liquidin the tank,the flux emitted from magnets within the floatworks upon the reed switches ON or OFF. By measuring voltage across the transmittercircuit, the level of the liquid can be calculatedaccording to the changes in circuit resistance. The converted signal is sent to the control boxvia I.S. barrier in the control room or to a localindicator as the case may be.
Standard SpecificationLevel Detecting Part
Type
Anti-Explosion Structure
Measuring Range
Specific Gravity
Viscosity
Detecting Accuracy
Allowable Temperature
Allowable Pressure
Read Switch with Magnetic Float
Ex ia C T6
50m, max
0.5 and above(of liquid in tank)
15,000sec. Redwood No,1 max.
20mm (option:10mm)
-60...+150 (stand.), -162 (option)
3kgf / (option:80kgf/ ,max.)
Temperature Detecting Part
Type
Measuring Range
Detecting Accuracy
Two-terminal IC, temp, Transducer
-55/+150
2
14 15PANASIA CO..,LTD.
General Operating PrincipleThe PANASIA high level alarm sensor consists of magnetic float and reed switch built in guide pipe.When the magnetic float moves upward with rising level, the hermetically sealed magnetic reed switch insidethe pipe will be de-activated. This switch will be in an open-state position, which output alarms.When the magnetic float moves down ward with falling level, the reed switch switch will be activated and willbe in a closed-state position (non alarm position).This means a normally operated fail to safe loop.The 95% switch is normally for high alarm.The 98% Switch is normally for high-high alarm(overfill alarm)A test lever is provided for manually functional test to check integrity of high level alarm system before cargoloading.
RemarkCargo Tank High & Overfill Alarm system is throughly designed according toUSCG latest requirements and are to be required by IBC Code
Magnetic Float TypeHigh & Overfill Alarm System
Technical Specification
Detection units
Detecting Accuracy
Switch Contact Rating
Specific Gracity
Material
Anti-Ecplosion Structure
Allowable Pressure
Connection Size
Alarm Point
Type approved by
Reed switch with magnetic float
5mm
250VAC, 1A
0.6 above
High & Overfill Alarm Switch Overfill Alarm Switch
Operating Signal
Connection Diagram
Electric Horn with Strobe Light High & Overfill Alarm Unit
Air Horn
Air supply 6~8 bar
PR-30EX-Number of float
: 1 float: 2 floats
Housing-SUS316Flange-SUS304/SUS316Guide pipe-SUS304/SUS316Float-SUS316, Titanium
Intrinsically safe type
6kgf/
Installation-JIS 5K 100A FF/125A FFJIS 5K 125A FF(with chamber)
Conduit-JIS 5K 32A or JIS 5K 40A
High alarm-at 95%of cargo volumeOver fill alarm-at 98% of cargo volume
KR,ABS,DNV,LRS,BV,GL,NK,RINA
Model:PR-30EX-
Model:PR-30EX-2 Model:PR-30EX-1
16 17PANASIA CO..,LTD.
FeaturesMaintenance FreeDesign of no moving part and simplified structure resulted strong enough and maintenance free product, which is endurable sloshing wave or exces vibration in the tank.For all kind of liquid This equipment is sustainable to all kind of liquid in the tanks, such as crude oil, high viscous bunker oil, petroleum products, chemical, etc. And no correction is required for the specific gravity.Check apparatus before loadingSpecially designed magnetic circuit is given for the operational check before loading cargo in the tank, which is required by SOLAS and Federal Rule for Coast Guard.Tank Pressure MonitoringBuilt-in type pressure sensor could be provided additionally in the housing for oil/chemical tanker as option.
RemarkCargo Tank High & Overfill alarm system is throughly designed according to USCG latest requirements and are to be required by IBC Code.
Operating PrincipleThe sensor is based on the principle of distributed acoustic waves in a metal rod.If the rod is not covered by liquid then the sound waves are dispersed freely without any interference.When liquid covers the rod then the emission of sound waves is muffled and his interference is picked up by the sensor and transmitted to the alarm and control panel.On the alarm and control panel are displayed warning indication lights for set level 95% and alarm 98%signal when the set or alarm level is reached. The board contains relays which control the audio and visual alarms.
Acoustic Type High & Overfill Alarm System
Metalic rod
Netural part
Piezo-electrical transducer
Sensitive part Propagation of acoustic waves in side the metallic rod
10
Applications
Technical Specification Acoustic Type Level Switch
High level alarm and Overflow alarm under IBC code, USCG & IMO’slatest requirement in any type tanks, esecially cargo tanks on chemical/product tanker, crude oil carrier.
ELECTRICAL CONNECTION
Electrical connection Flexible Hose
Repeatabillty Top mounting < 3mmSide mounting < 1mm
Output
Power supply
Operating temperature
Electrical connection
Material
Weight
2 or 4 wires
Stainless Steel 316L
0.7k g (with L=100mm)
I.S approval
Protection
current loop with 16mA no alarm6mA alarm
EEX ia IIC T6
IP56
18 to 30V DCNominal 24V DC
Ambient -40 to +85Liquid -40 to +150
Model:PA-LW2
Model:PA-LW2
IntroductionThe AMRI-SEIL / PANASIA VRC system is designed for position indication and electro-hydraulic remotecontrol of hydraulically actuated valves. The principle of the VRC system is that pressurized oil, generatedby the power pack, is used to open or close the valve by means of the solenoid controlled actuator.
Valve Remote Control System
18 19PANASIA CO..,LTD.
The actuated valves are installed in safety area. (Ballast and Engine room etc)
Solenoid Valve RackSolenoid valves are used to control thedirection of oil flow to each actuatorsoperated by an electric signal from controlconsole installed in safety area.
Safety Area
Hazardous Area
The actuated valves are installed in hazardous area. (In-tank and On-deck)
Deck BoxThe deck box controls the functions ofeach actuated valve installed in hazardousareas via explosion proof solenoid valves.
Interface PanelThe interface panel consisting of relays,Power supplier, Converters and Barriers,etc., is required to communicate betweenvalves and computerized control system.
Automation SystemRemote operation by the computerized system
Electric linehydraulic pressure lineHydraulic returen line
Hydraulic Power PackThe hydraulic power unit consists of oil tank,electric motor & hydraulic pump which generatesthe required system operating pressure.
Control console & Mimic panelRemote operation of the conventional type by the controlconsole with mimic panel.
20 21PANASIA CO..,LTD.
Air Purge Type Tank Level & Draft Gauging System
Operating PrincipleThe operating principle is based on the measuring the hydrostatic head of the liquid by providing constantlow flow of air into a probe (called as sounding pipe) which opens at the tank bottom.When a light quantity of air (supplied from flow regulator) is discharged through the purge mouth at the tankbottom, An air pressure corresponding to the liquid level (considering the viscosity) will be built up in thesounding pipe. If the specific gravity of the liquid is known and a pressure in the sounding pipe is measured, it is possible tocalculate the distance from the pipe opening to the surface by means of the above expression. The pressure is read on the indicator graduated scale in meters or volume or percent of full tank.
Pressure switchfor alarm(option)
Constant flow regulator
Pneumatic indicator
Air purge head
Draft Box
Air supply unit
Specification
Type of system
Accuracy
Working temperature
Air flow consumption
Operating air pressure rating
Signal pipe
Valve casing
5 to 50N/min
4 to 7kg/
OD 8mm
alloyed brass with protect cover(SUS304)
one(1)-Line air purge system
1% of F.S, if drawn scaleindicator calss 0.5
-25 to + 75(It must be secured that the dew pointof the air lies below Min. Temperature)
22 23PANASIA CO..,LTD.
Electric Pneumatic Type Tank Level & Draft Gauging System
Monitoring Computer
Constantflow regulator
Electric indicator
Air supply unitP/I converter
4-20mA
RS-485
4-20mA
Signal distributorAnalog interface
module
Operating principle
The operating principle is basically the same as the levelmeasuement of air purge type tank level monitoring system.But Electric pneumatic type tank level gauging system haselectric reading and P/I Converter that converts pneumaticinput signal to 4-20 mA output signal in addition to air purgetype system.
Application
Ballast tank level measurement.Draft measurement.Engine room tank level measurement.(F.O, D.O, L.O, etc)
P/I converterThe upgraded P/I converts is provided to converter anpneumatic pressure into an electronic signal for remotedisplay of tank level and draft gauge on CRT and /orElectric indicator.Unlike the pneumatic indicator possible to be damaged byexcess-pressure, this P/I converter is free from inletexcess-pressure without even Gauge saver.
Model : P940Output current : 4 to 20mA DC,
2-wire system.Protection against inlet excess-pressure.
Air purge head
Draft Box
Electric Pneumatic TypeTank Level & Draft Gauging System
Specification
Type of systemAir supply
System accuracyCPUOS
ROMRAM
DisplayInput
Operating temperatureOperating humidity
DimensionWeight
Electric Power
Output
one-line air purge system6~10bar, set to 4bar
1% of Full scaleIntel StrongARMTM SA1110-206MHzLinux for embedded system16MByte Flash ROM64MByte SDRAM, PC1004 20 character VFD (Vacuum Fluorescent Display)10 air pressure from tanks
2 serials (built - in RS232/485)1 LAN 10base -TAnalog output (4~20mA, 1~5V)-OptionDry contact - Option
-10~45 (under dry air condition)0~80RH450 350 240(mm)App. 20kg85~250VAC, 50~60Hz
Introduction
Level Pride is specialized on electric pneumatic air purge system. Level Pride is equipped with all thenecessary components such as air supply unit, constant flow Regulator Module(PA-1500), sensorModule(PAMX-2000)in one module. You need just one module for measuring 10 tanks. If you have moretanks to monitor, just plugging each other with LAN cable and set the some configuration. One of the LevelPride module which is configured as master finds all the slave modules connected with and calculatesinformation automatically.
Features
10 Tank interface without any additional components. (Air purge System)-Built-in Air supply unit, Constant Flow Regulator Module (PA-1500)-Sensor Module (PAMX-2000), 12 bit A/D converter.Various kind of correction function.-Specific Gravity, Trim & Heeling, Sensor position-Volume converting according to the Volume table Various display format of the tank information to the userIndustrial standard serial link and Ethernet link-10Mbps LAN 1 channel-RS232/485 1 channel eachWindows based Configuration program for easy setting & calibration-Module/Ship/Tank/Channel setting
24 25PANASIA CO..,LTD.
System diagram
LEVEL PRIDE
26 27PANASIA CO..,LTD.
FeaturesHigh accuracyLong term stability4-20mA Output signalEEx-version(EEx ia llC T6)Easy installationEasy maintenance
ApplicationThe level transmitter can be used for measuring levelcontents in open such as WBT.F.O TK. in E/R etc. Additionally the level transmitter isavailable in Ex ia-version.It is easy to install in all types of vessels because all of theparts is in one.The Electro-pneumatic transmitter has developed focusedon saving on installation cost with best reliability.
Function
Technical data
The principle of operation is based on the measurement of the hydrostatic pressure at the bottom of a tankwhere air is injected continously through a sounding pipe.A pressure corresponding to the level of the liquid will be built up in the sounding pipe.This pressure will be measured by the transmitter and converted into a 4 to 20mA signal.
Electric Pneumatic Type Level Transmitter
Output
Load equation
e.g.:24V supply Air supply
Min. pressure
Air consumption
Power supply
Effect of voltage variation
Damping
Insulating current
Accuracy
Material
Temperature stability
4-20mA, 2wire system
RL (Vcc-10)/22[ ]
RL<636
20mm from 0 to 10meter level40mm from 10 to 35meter level
clean dry air 4~8bar
0.5bar above range
approx. 30 IN/h
Naval brassstainless steel
-10 ..+70 <=0.5%for main range (overall temperture-range)
range 10...30Vzero point 0.005% pro Vspan 0.001% pre V
0-200s adjustable
500V
nominal 24V DC
OUTPUT4-20mA
Analog Interface Module
Digital Indicator
Monitoring Computer
28 29PANASIA CO..,LTD.
1:1 Converter(Pneumatic Tank Level Gauge)
Operating Principle
Application
On one side, the diaphragm is affected by the medium in the tank which is to be measured. the pressure bywhich the diaphragm is affected is the hydrostatic pressure of the fluid or gaseous medium. On the other side, the diaphragm is fastened with the pressure converter, forming so a pressure chamber. Viaan air supply and a throttle, measuring air is applied to the pressure chamber where a pressure correspondingto the hydrostatic pressure of the medium develops. This pressure can be shown by an indicating Instrument. the pressure on the supply of measuring air must always exceed the highest media pressure. Excess air is blown out through the nozzle in the center of the pressure converter.To avoid distortion, the flange must be fastened at least 4points before final welding. Connecting tubes ofstainless steel or copper are to be used between pressure converter and indicating instrument/air supply.
Primarily for as an indirect continuous measurementof level and cubic contents respectively of liquid incontainers and tanks.Our 1:1 converter is espectaily suitable for hygienicpurposes within the food, beverage and chemicalindustries as well as for potable water tanks.
Technical Data
Measuring rangeAir supply
Air consumption
Viscosity
Tolerances
Temperature rangeRasponse time
0-30m H2O1.4bar or minimum 1.2 measuring rangeAt 1.4 bar air supply approx.30 /h (emth tank, otherwize lessat 2.5 bar air supply approx.40 /h
3500 Redwood 1 sec.(measured with water)Including reaction sensivity and hysteresis at 1.4 bar.at emtpy tank and free discharge nozzle : max.25mm>0.1m tank level measured from middle of diaphragm : max. 25mm 0.75%The O-point drift depends on the pressure loss caused by possible hose/ tubemounted on the discharge nozzle.
-40 to + 200 (4bar)Depends on tube dimension and tube length from pressure converter toindicating instrument as well as supply
Air supply1.4bar1.4bar1.4bar1.4bar2.4bar
Internal tube6mm6mm6mm6mm6mm
Pipe length30m50m
100m300m100m
Reponse timeapprox.10sapprox.20sapprox.50sapprox.4minapprox.5s
Change in level55mm/s55mm/s55mm/s55mm/s55mm/s
Electric Pressure TypeLevel Transmitter (LEVEL-3000)
Tank Contents Transmitter
30 31PANASIA CO..,LTD.
Connection on junction box
Connection on junction box
Outline / Dimension
Measuring Range
Parameter
Power Supply
Transducer TypeNon-Linearity
Long Term Stability
Burst PressureOperating Temperature
>200 bar-25 ~ 85 (Option125 )
Total Error Band
Over Pressure
Piezo-Resistive Type Transducer0.25% @ 20
Max 0.1% / year
Max. 2.0% @-25 ~ 85
Min. 3 ���������
������������������������������������� ������������������
���� �����������
��������������������������
�����
Transducer Range
Output
Current Limiting
Built-in Temperature SensorTransducer/Transmitter Material
Protection ClassEx-Approval
4~20 mA DC looppowered 2 wire
Typically 20.8 mA(Programmable)
0~0.25bar, 0~0.5bar, 0~1bar, 0~2bar, 0~4bar, 0~6bar, 0~25bar, -1~5bar Each spanrange is programmable in use calibration kit.
The Power supply can vary from 10 ~ 38 VDC.Permissible load resistance is shown graphically below.
This is a 2-wire 4-20 mA level transmitter consisting of a transducer and an amplifier connected via a 6-core vented cable. The transducer is a pressure sensitive silicon micro strain gauge sensor mounted in a glass tometal seal. The sensor is protected by an isolation diaphram, electron beam welded to the transducer housing, with an oil filling between the sensor and the diaphragm. Pressure changes in the front of the diaphragm willbring a resistance change in the Wheatstone bridge of the transducer. This change in the Wheatstone bridge will be transmitted to the amplifier as a change in the electrical signal.
Application�������������BALLAST TANK REMOTE READING�������������DRAFT REMOTE READING�������������HEELING AND TRIM REMOTE READING�������������FUEL OIL TANK REMOTE READING�������������WASTE WATER, WELLS, LOCKS, RIVERS ETC.
Feature
Technicall specifications
�����������
�����������
���������
PIEZORESISTIVE SENSOR ELEMENT�����������
�����������
���������
STAINLESS STEEL/TITANIUM MATERIAL�����������
�����������
���������
CONNECTABLE TYPE(CABLE CONNECTION PLUGGABLE)�����������
�����������
���������
TEMPERATURE MEASURING WITH PT100(OPTION)�����������
�����������
���������
DIRECT OUTPUT TYPE(NO AMPLIFIER BOX)�����������
�����������
���������
HIGH MEASURING ACCURACY�����������
�����������
���������
HIGH TEMPERATURE STABILITY�����������
�����������
���������
NO HYSTERESIS�����������
�����������
���������
MARINE CLASS APPROVAL
Pt100 (Optional)SUS316L / Titanium
IP68 (Fully Submersible)Ex ia IIC T4
32 33PANASIA CO..,LTD.
Water Ingress Alarm System
This system is designed to detect the presence of water inthe cargo holds and intended for usage on bulk carriers.The system is in accordance with
SOLAS chapter XII/12IMO Res. MSC.145(77)IACS SC 180
Feature
Principle of Operation
Specification
PR-30EX(Float type)
HR-665261(Rod type)
No moving partReliableNo damage by cargoEasy to maintenanceInsensitive to cargo solids
Electrode type level switch is suitable for level detection in conductive liquid. If the electrode comes into contact with the liquid, the A.C current will flow through the liquid and complete thecircuit. This AC current can be amplified and fed into electronic converter in sensor housing that detectschanges in its input current caused by rising medium. this change are converted into a corresponding currentchange. If the changes exceeds an adjustable limit value, the output current rises discontinuously to > 3.4mAThe I.S.Barrier/signal converter in alarm panel uses this information to switch isolated contacts.
Certified to
Ambient temperature
Liquid temperature
Pressure
Housing material
Process connection
Protection class
Normal voltage
Ex ia C T6
-25 ~+70
-20 ~+70
0~5 bar
SUS316
Thread G1-1/4A or Flange.
IP56, IP65, IP68
4.6V to 30V DC
Normal current
Measuring voltage
Max. no-load current
Max. short-circuit
Frequency
unswitched < 1mA,switched > 3.46mA
AC5V
1
50kHz
Major FunctionPre-alarm at 0.5mMain alarm at 2mFault /malfuncition alarm.(line monitoring)Override/ interlock functionAutomatic cancellation of override conditionOverride indicationPower failure alarmPower automatic switchoverLamp/buzzer testCommon alarmAlarm time delayFunction test in-situ.
Least cost to retrofitexisting bulk carriers
Design to minimizea cost to shipowner
Configuration
The water detectors are installed at a height of 0.5m above inner bottom and another at a height not less than 15% of thedepth of the cargo hold but not more than 2.0m. In any ballast tank forward of the collision bulk head, the detector isinstalled at a height not exceeding 10% of the tank capacity. In any dry or void space other than chain locker, any part ofwhich extends forward of the foremost cargo hold and the volume of which exceeds 0.1% of the ship s maximumdisplacement volume, the detector is installed at a height of 0.1m above the deck.
34 35PANASIA CO..,LTD.
Pressure Monitoring System
Computer Monitor
RS-485
4-20mA
4-20mA
Analog interfacemodule
Pressuremonitoring panel
Electric horn with strobe light
Barrier Barrier
GeneralThe pressure monitoring system is designed for cargo tank & manifold pressure monitoring for any number of tanks. The vapour pressure monitoring system is intended for pressure monitoring of waste return lines.
The PANASIA pressure transmitter is carefully designed to meet a harsh marine application for the tank pressuremonitoring system in accordance with SOLAS II-2/59 amended in 1996, and vapour pressure monitoring system requiredunder 46CFR part 39. 20-13 of VECS.The transmitter is a high quality and accuracy semi-conductor type especially suitabe for the low pressure to be measured.
Operating PrincipleThe transmitter measures the pressure by means of a semi-conductor sensor. Pressure changes in front of the diaphragmwill bring about a resistance change. The change in resistance is linearly proportional to the applied pressure and isamplified by an integrated electronic amplifier to give an output signal. The electrical signals from the pressure transmitterson deck are connected to zener barriers in the monitoring cabinet equipped with pressure alarm lamp, buzzer and pressureindicator in the cargo control room.
Technical SpecificationPower supply
Accurcy
Response time
Measuring Range
Over load pressure
Burst pressure
Output signal
Process Connection
Approval
Enclosure
Ambient temperature
Medium temperautre
DC 10-30VDC
0.5% FS
<1ms/10...90% FS
0~25bar
Min.3xFS
200bar
4-20mA
G1/2A(PF 1/2 )
KEMA 03ATEX1127
IP65(DIN 43650)
-25~+85 (T4)
-25~+100 (T4)
HA
ZAR
DO
US
AR
EA
SA
FETY
AR
EA
36 37PANASIA CO..,LTD.
Vapour Emission Control System(O2 Content and Vapour Emission Pressure)
General
Main Components
This is a complete system to monitor oxygen gas content and vapour pressure in the waste vapour andmanifold lines from vessels. this system complies with USCG Regulation for Cargo vapour emission controlsystem for tankers. All necessary parts are intrinsically safe protected.
Oxygen Gas & Vapour Press Detection Cabinet
Oxygen sensorFlow meterPressure transmitter
Filter & Selection valveAnnunciatorDigital indicators
Version
FUNCTION1.OXYGEN CONTENT DISPLAY2.HIGH OXYGEN CONTENT ALARM(8%)3.VAPOR PRESS. MONITORNG4.VAPOR PERSS.
HIGH ALARM(0.125bar)LOW ALARM(0.01bar)
HAZARDOUS AREA SAFETY AREA HAZARDOUS AREA SAFETY AREA
Operating Principle
Version
Technical SpecificationPower supply
Air supplyFuse
Oxygen SensorAlarm Points
Set PointExplosion Proof
Pressure TransmitterAlarm Points
Set PointHydrocarbon Sensor
Vaccum pumpCalibration
115/230 VAC (50-60 Hz)6-8 bar10 A0-25% Volume10-100%EEx ia IIC T4200mbar20-100% Full Scale0-100% LEL n-Butane in airOil less carbon vane pumpTest gas from gas bottles
The system has four(4) sample points and only one sample is directed and monitored individually through selecting valveat the time. The sampling lines are run from the respective sample point to the panel in a hazardous area. Sampling gas ispurged to a atmosphere. Oxygen sensor is designed for monitoring content from 0 to 25 V%. Indicator in control roomactivates High O2 alarm at 8% which was preset and gives audible and visual. Flowsensor fitted on flowmeter monitorssampling gas low flow and activates alarm when flow rate is under minimum flow level.Pressure transmitter monitors the pressure in waste vapour and manifold line. Low and High pressure alarm is set at 10mbar and 120mbar respectively.
38 39PANASIA CO..,LTD.
Fixed Gas Detection System
General P & ID Program
The system is designed to provide protection of the following areas : Cargo pump rooms; Cofferdams ; Pipe tunnels ; Ballasttanks and double bottoms ;Void spaces ; Other empty area’s adjacent to slop tanks. Additionally, stool tanks and other empty areas adjacent to cargo tanks can be protected.
When locating fixed sampling points within ballast tanks, areas where an explosion is most likelyto occur must be assessed.The risk of explosion is mainly related to the release of cargo vapours through the ballast vents in the top of the tank, duringballast filling. Hence it is considered sufficient that detection takes place in the upper part of the spaces whengasconcentrations reach detectable levels. We advise that ballast tank-sampling positions belocated at the top of the tank.
The sampling system extracts gas samples from a maximum of 48 lines and the default sample sequence is to cycle fromchannel 1 to 48 and then back to channel 1 again. The time that thesystem samples on a channel can be altered for eachsample line to compensate for varyingsample line lengths.
Flame arrestors are constructed from stainless steel and designed to prevent the propagation offlames from the analyzing unit if a fire occur within the unit. Flame arrestors are provided as looseitems to avoid any damage to the unit during dispatch.
The sequential gas sample system is a multi point gas-sampling unit designed to detect and providealarms for the presence of flammable and hydrogensulphide gases within the water ballast tanks and void spaces.
The system is designed to extract a gas sample fromeach sample point via sample piping to the analysingunit where the flammable and hydrogen sulphide gascontent is measured. By using solenoid valves, the unit provides an effective way of sampling multiplelocations using only one sensor for gas detection.
The system utilises a heavy-duty sample pump toextract a sample of gas from each of the sample pointlocations. The extraction circuit incorporates a flowsensing device to annunciate a flow failure if the pumpcease to operate or sample lines become blocked.Solenoid valves are used to select each sampling linefor analysis in a sequential or pre-programmedsampling sequence. Furthermore, the system isextendable by adding additional valves, which areautomatically recognised and activated. Flame arrestors are installed on all sample linesiaccordance with class regulations.
The system can supply information to the vessels AMSsystem via a communications protocol which allows fora real time flow of information including the currentlocation being sampled and the gas concentrationlevel at this location.
Main supply
Emergency supply
No of sample points
Sample time per line
Power shut down 30% LEL
220VAC 60Hz
220VAC 60Hz
Up to 48
60 Seconds
Sensor No.
Sensor type
Range
Calibrated Gas
Low alarm trip point & type
High alarm trip point & type
Sensor No.1
Infra-Red
0~100% LEL
Butane
10%Rising
30%Rising
Sensor No.2
Electrochemical
0~50ppm
Hydrogen Sulphide
5ppm Rising
10ppm Rising
Sensor No.3
Electrochemical
0~25% VOL
Oxygen
16% Falling
24% Rising
Specification
LCD Display - High Alarm Lamp - Low Alarm Lamp - System Failure Lamp - Main/Pre Flow Failure Lamp - Sensor Fault Lamp - Standby & Main Power Supply
Indicators
40 41PANASIA CO..,LTD.
Pump RoomBilge High Level Alarm System
General
IMO MSC-67 issued a safety circular recommending measures to take to prevent explosion in oil tankercargo pump room for new and existing tankers. OCIMF also recommends that all pump rooms shoud beprovided with a high level alarm which activates audible and visual alarms.
Operating Principle
Level switch monitors level in bilge well. With rising level, switch gives output signal to alarm panel andthen activates audible and visual alarms.
Application
Pump Room BilgeE/R Bilge
HA
ZAR
DO
US
AR
EA
SA
FETY
AR
EA
Temperature Monitoring System
PC-based Programmable Controller
Temperature Monitoring System
PATM-5000 series Module is designed for being integrated in a housing and fully compatible with RTD. thermocouple andthermister etc,. This module can be supplied as complete or partial system with later additions.
Cpu : 16-bit microprocessorMemory : Up to 256KB Flash ROM, 256KB SRAMOperating system : Rom-DOSBuilt-in Paradym-31 Runtime Engine(ADAM-5510/P31 only)
Built-in realtime clockBuilt-in Watchdog Timer3 communication ports supported(COM 1:RS-232;COM2:RS-485:COM3/Programming Port:3-wire RS-232)
3-channel RTD Input Module16-bit resolution3 RTD input channelssoftware configurable for Pt or Ni RTD inputInput connection:2,3 or 4wires
Distributed DA&C system Based on RS-485
Support master/slave communicationASCII command/response2-wire, multidrop RS-485 networkTransmission speeds up to 115.2Kbps
7-channel Thermocouplelnput Module16-bit resolution7 differential input channelsSoftware configurable for T/C, mV, mA input3000 VDC isolationExternal cold junction compensation
Computer Monitor RS-232
42 43PANASIA CO..,LTD.
Flat Type Glass Level Gauge
PA-FLG-P100 SeriesThe PANASIA Flat type level gauge is designed according to JIS standardspecifications. This type level gauge is used for marine oil tanks,excludingthose of flash point of 60 below. Flat type level gauge allow an excellentobservation of colorless liquid level through reflection of several parallelgrooved glass.
Gauge Body
Water space
Gauge glass
Light ray Light ray
Steam/gas space
Operating principleThe principle of reflex glass is based on the difference in the refractive indices of liquid and gas or in particularof water and steam.. The liquid column is contained within the recess of the centre-piece behind the gaugeglass which is clamped within the gauge body. If a ray of light encounters the surface of one of the 45slanted grooves in the gas or steam space. It is reflected to the opposite surface of the groove and from theretotally reflected-back into the direction of observation.The steam or gas space therefore appears as silver-white.The gauge glass has prismatic right angled grooves, On the side facing the water and steam spaces. Lightrays entering from outside the gauge are either absorbed or reflected depending upon whether they enter thewater or steam space. The light ray which encounters the surface of a groove in the liquid space is almost totally absorbed. The liquid behind the reflex glass therefore appears back.
Model Classification and Specification
JIS Code
PA-FLG-P100
Valve typeUpper Lower
MaterialValve channel Glass
Type Connectionsize
Center tocenter
Designpressure
Max.temp’
A
B
C
Topvent
Tankreturn
selfclosing
self-closing
self-closing
JIS5K20A,
25AJIS
5K20A,25AJIS
5K20A,25A
3 /
3 /
3 /
BC6
BC6
BC6
SUS304
SUS304
SUS304
Borosilicate
Borosilicate
Borosilicate
150
150
150
275~
5100(m/m)
self-closing
Installation
PA-FLG-P100
SECTION A = A
CAUTIONSupport bracket to be placed andspaced Max. 1000mm between upperand lower valve.
A-TYPE (AIR VENT) B-TYPE (TANK RETURN) C-TYPE (SELF-CLOSING)
The level gauges shall be classified into three type A,B,C according to the shape of the upper bodyPlease contact our factory if other specification are required.
44 45PANASIA CO..,LTD.
Reflex Type Glass Level Gauge
PA-RLG-P100 SeriesThe PANASIA reflex type level gauge consists of a sturdily constructed body, glass and cover securely fixedby u-bolts to endure high pressure.This type level gauge feature serveral parallel grooves cut into the glass surface that is in contact with liquid.Thus the level of even transparent liquid can be clearly observed.
PA-TLG-P100PA-RLG-P100
Model Classification and Specification
Model
PA-RLG-P100
PA-TLG-P100
Valve type
Upper Lower
Material
Valve Frontchannel
Backchannel
Type Connectionsize
Center tocenter
Designpressure
Max.temp’
A
B
A
B
Ball
Self
Ball
Self
Ball
Self
Ball
Self
20 /
20 /
SUS304 SUS304 SUS304
SUS304 SUS304 SUS304
SUS304 SUS304 SUS304
SUS304 SUS304 SUS304
200
200
320~
2870(m/m)
The level gauges shall be classified into three type A,B,C according to the shape of the upper body.Please contact our factory if other specification are required.
PA-RLG-P100
BALL CHECK
ANSI 1150#
ANSI 1150#
SELF-CLOSING
46 47PANASIA CO..,LTD.
Magnetic Float TypeLevel Gauge
Operating principle
The measuring pipe (chamber) is connected to the tank to form a float chamber that has the same level asthe tank. A float with a built-in magnetic floats freely on the surface of the liquid and transmits its movementin the pipe, without physical contact, to an externally mounted indicating strip (Indicator).The indication strip is placed on the ou side of the pipe and consists of numerous magnetic flaps which arewhite on one side and red on the other, As the float passes the red/white flaps, the flaps are one after theother turned 180 around their own axis.The flaps change from white to red with rising level and from red to white with falling level.The magnetic level gauge is particular advantage wherever dangerous and toxic media calling for carefullevel monitoring.
Features
Description of model
No harms to the environment. Safety Guarantee.No leakage to atmosphereNo maintenance costsEasy to read.Suitable for pressure tankAlarm contacts.(option)Analogue output signal, 4-20mA.(option)
PLG-65 -Level Transmitter
:Output 4~20mA:Output 1:Level switch
T
STR
Mounting Type:Side mounting:Top mounting:High pressure/ temperature
MS
HMT
PLG-65MS- -
PLG-65MT- -
PLG-65H
Side 5 / 200 Over 0.8
Over 0.85
Over 0.85
+/-10m/m
+/-10m/m
+/-10m/m
SUS304 SUS304
SUS304 SUS304
SUS304 SUS304
Poly-carbonate
resinAluminum
Poly-carbonate
resinAluminum
Poly-carbonate
resinAluminum
5 / 200
50 / 300
JIS 5K 25A Max.5000mm
Top JIS 5K100Aor 125A
Max.2500mm
Side 5K 25A Max.2500mm
Symbol Mountingtype
Connectionsize
Measuringrange
SpecificGravity Accuracy
Chamber Float rotor rotor columnnMaterialWorking condition
Press. Temp.
Model Classification and Specification
Level Switch Unit and Level Transmitter Specification (Option)
Description
Levelswitch unit
Levelswitch unit
Reedswitch
Reedswitch and
resistor
Drycontact
4~20mADC
Two-wire
125VAC,0.5A
N/A
SPST,SPDT
N/A
N/A
DC 24V
+/-5m/m
+/-% ofF.S
AC
AC
N/A
SUS304
Max.6
N/A
N/A
400m/m~5000m/m
120
120
Weatherproof
Weatherproof
Module Output Contactrating
Contactform
Powersource Accuracy
Housing Transmitter
Material No ofpoint
Measuringranger
Nax.working
temp.Enclo-sure
These switch unit and transmitter may be used for intrinsically safe application in hazard when connected through approved zener barriers (Exia llc T4)Please contact our factory if other specifications are required.
48 49PANASIA CO..,LTD.
GeneralThe PANASIA PCG-150 Series tank contents gauge requires no external power source for operation. The instrument is completely automatic and provides continuous indication of tank contents without the aidof batteries or hand pumps. This gauge unit is simply composed of Diaphragm, capillary tube and dial type indicator.
ApplicationGenerally applied to fresh water, Lub oil, Diesel oil, Heavyfuel oil and solvent gasoil and noncorrosive liquid.
Self-Powered Contents Gauge
PCG-150 Series
Model:PCG-150 Series
SpecifiationGauge size
Mounting type
scale of indication
Accuracy
Enclosure
Overload
Operating temperaturerange
Length of capillary tube
Dial 150, 100, 160
Side, submersible mounting
Height(m) & volume( )
1.5% of full scale
Weather proof
Min, 100% of full scale
-20 to +100
5 meters, 2 meters (standard), other(option)
Operating principleThe diaphragm is affected by the hydrostatic head medium column in tank, which apply pressure to the oilfilled capillary. The pressure applied to capillary expands bourdon tube of indicator, so that the indicator displays the levelcorresponding to actual tank level.
Description of modelPCG -
���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
Type of sensor connection: Socket connenction: flange connection: lsolating valve connection
S
VF
Size of Indicator: 100 dial gauge : 150 dial gauge
MSMT
FOR HIGH VISCOSITY FLUID(PCG-150V)
FOR LOW VISCOSITY FLUID(PCG-150S)
SUBMERSIBLE TYPE
GAUGE SEAT
CONTENT GAUGE
FOR HIGH VISCOSITY FLUID(PCG-150F)
NoteDimension H must be complied with because the indicator is sensitive to its mounting position.
50 51PANASIA CO..,LTD.
Operating principleThe PANASIA dial type float level gauge consists of float, measuring steel wire and indicating unit as maincomponents. A float accurately follows liquid level variations in the vertical direction (horizontal movement of the float is wellrestricted by guide pipe).Vertical movement of the float is transmitted throught a measuring wire to the indicating unit, in which themeasuring wire is wound around a tape pulley kept under constant torque by constant spring.the vertical movement is converted into rotation of the tape pulley in this way.This rotation is transmitted through a gear system to an indicator pointer which reads the liquid level on a scaledial of indicating unit.
Dial Type Float Level Gauge
Application
Model : PDG-150 SeriesGenerally applied to Water tank and L.O, D.O andH.F.O.tanks.Besides, magnetic coupling type dial float level gaugeis applicable to the liquids that emits corrosive,inflammable or poisonous gases.
Model Classification and Specification
PDG-150SC-T
Top(withchamber)
Top(withchamber)
Top
Side
Please contact our factory if other conditions are required
Top(withguide wire)Top(with
guide wire)
PDG-150SW-T
PDG-150SW-S
PDG-150SC-S
PDG-150SI-TPDG-
150SI-S
Type
Directconnection
type
Magneticcoupling
type(indirecttype)
Model Mountingtype
Measuringrange
Indicationsystem
Specificgravity Accuracy
Working condition Material
Temp. Press. G/G head Tape Float Guide pipe
PDG-150 Series
0~5m
0~5m
0~5m
0~5m
0~5m
0~5m
One-Point
One-Point
One-Point
One-Point
One-Point
One-Point
0.7~1.5
0.7~1.5
0.7~1.5
0.7~1.5
0.65~1.5
0.65~1.5
15m/m
15m/m
15m/m
15m/m
15m/m
15m/m
150
150
150
150
150
150
0.2 /
0.2 /
0.2 /
0.2 /
2 /
2 /
AC
AC
AC
AC
AC
AC
SUS304
SUS304
SUS304
SUS304
SUS304
SUS304
SUS304
SUS304
SUS304
SUS304
SUS316
SUS316
N/A
N/A
N/A
N/A
SUS316
SUS316
CASE-1 DIMENSION
CASE-2 CASE-3
�
52 53PANASIA CO..,LTD.
Operating principlePANASIA magnetic float level switchs monitor and control liquid levels in open or closed tank. A permanent magnet is part of a float which rises or falls with the changing liquid level.This magnet repells another magnet located opposite in the switch housing. In this way it causes a snap actioncontact effect. A switch unit provides on-off contacts.
Float Type Level Switch
FeaturesEasy maintenanceSafe operating conditionsReliable
ApplicationFresh water tank, Heavy fuel oil tank.D.O.tank, Sludge tank, Sewage tank, etc.
Technical data
Switch rating
Liquid density
Contact
Ambient temperature
Medium temperature
Switch hysteresis
Rated Pressure
electrical microswitch, change contact, SPDT, DPDT
250V AC, 3A
min. 0.7kg/d
20mm height at 0.9kg/d specific weight
3kg/ (standard), up to 12kg/ (option)
-30 to +70
-25 to +135
Installation
Protection of Switch housing
Float material
Flange, housing
horizontal
IP 56, IP 68(option)
sus 316L
SUS 304, ALDC 8
A(ROD LENGTh) : MAX.500MMB(DIFFERENTIAL) : MAX.300MM
PM-12H PM-12H-T
PM-12H-E PM-12H-S
PM-12H-D PM-12H-C
PM- 12 ���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
-���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
Option: Test Device: Cranked: Explosion Proof: Submersible: Differential
T
ESD
C
: Horizontal mounting : vertical Mounting
HV
Test DeviceHousing
switch unit
Megnet
Float
54 55PANASIA CO..,LTD.
Operating principlePANASIA magnetic float level switchs monitor and control liquidlevels in open or closed tank. A permanent magnet is part of a floatwhich rises or falls with the changing liquid level.This magnet repells another magnet located opposite in the switchhousing. In this way it causes a snap action contact effect. A switch unit provides on-off contacts.
Float Type Level Switch
Features
Easy maintenanceSafed operating conditionsReliable
ApplicationFresh water tank, Heavy fuel oil tank.D.O.tank, Sludge tank, Sewage tank, etc.
Technical data
Switch rating
Liquid density
Contact
Ambient temperature
Switch hysteresis
electrical microswitch, change contact, SPDT
250V AC~3A
min. 0.7kg/d
20mm height at 0.9kg/dspecific weight
-30 to +70
Medium temperature
Rated Pressure 3kg/ (standard), up to 12kg/ (option)
-25 to +135
Installation
Protection of Switch housing
Float material
Flange, housing
horizontal
IP 56, IP 68(option)
SUS 316L
SUS 304, ALDC 8
PM- 12 ���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
-���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
Option: Test Device: Cranked: Explosion Proof: Submersible: Differential
T
ESD
C
: Horizontal mounting : vertical Mounting
HV
PM-12V PM-12V-T
PM-12V-E PM-12V-S
PM-12V-D
Housing
Switch Unit
Magent
Float
56 57PANASIA CO..,LTD.
Operating principleOperation is based upon a buoyancy principle whereby a spring is loaded with weighted displacers which areheavier than the liquid.Immersion of the displacers in the liquid results in a buoyancy force change, which moves the spring upward.Since the spring moves only when the level moves on a displacer, Spring movement is always a small fraction of the level travel between displacers. A magnetic sleeve is connected to the spring and operateswithin a non-magnetic barrier tube. Spring movement causes the magnetic sleeve to attract a pivoted magnet, actuating a switch located outside the barrier tube.Switch set points are achieved by moving displacer modules up or down the displacer wire/rod.
Displacement TypeLevel Switch
Description of model
PM - 90 ���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
-���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
: Displacer: Displacer: Displacer
1
32
: With Test Device T
Optional informations1.Special material(SUS316, SUS304) for weted parts including mounting flange, chamber is also available on
request.2.Switch contact type : SPDT, DPDT
PM-90T-1
PM-90T-2
PM-90T-3
High orLow alarm or control
10
10
10
180
180
180
10
10
10
0.85
0.85
0.85
Topflage
Topflage
Topflage
15/20a,b,c
15/20a,b,c
15/20a,b,c
250VAC,5A
250VAC,5AX2
250VAC,5AX2
ACIP56
ACIP56
ACIP56
SS400or
SUS304
SS400or
SUS304
SS400or
SUS304
SS400or
SUS304
SS400or
SUS304
SS400or
SUS304
SUS30478,
200L
SUS30478,
200L
SUS30478,
200L
JIS 5K 80A
5K 100A10K 80A
10K 100A
High orLow alarm or control
High alarm/Mid.
low control
Max.Press.( / )
Model ApplicationMax.
Temp.( )
Setting accuracy
( )
Mountingflange
(standard)
Min.Sp.Gr. Connection Cable
gland
Switchcontactrating
Material
Housing Flange Displacer Chamber
Specification
1:Differential is the allowable range from the acutating level of the switch to the reset level
PM-90-1 PM-90-2
PM-90-3
MODES PM-90-1Upper :30 to 50Lower :30 to 50
NO
COM
NC
NO
COM
NC
NO1
COM1
NC1
NO
COM
NC
NO1
COM1
NC1
NO2
COM2
NC2
PM-90-2Upper :30 to 50Lower :30 to 50
PM-90-3Upper :30 to 50
Lower:200 to 4500DIFFERENTIAL
(mm) 1
CONTACTCONFIGURATION
(OPERATING SIGNAL)
(VIEW “A”)
(OPERATING SIGNAL)(VIEW “A”)
(OPERATING SIGNAL)
(VIEW “A”)
58 59PANASIA CO..,LTD.
Operating principle
Application
Description of Model
Technical data
The reed switch type float level switches consist of amagnetic float and reed switch as main components. A float equipped with permanent magnet moves up anddown with the fluid level between two stoppers and itsmagnetic field actuates a hermetically sealed reed switchincorporated in guide pipe.The switches can be normally open, normally closed orchange-over contacts. The advantage of this principle;there is only one moving part,the float.This actuates the reed switch with its magnetic field withoutcausing any wear. The reed switch is itself totally isolated from the media.These advantages give the user safe, repeatable, accurateand high operational reliability with low maintenance over along and trouble free life.
-Fresh water-Sea water-Low viscosity liquids
Reed Switch TypeFloat Level Switch
-20 ~ 1005kg/ ( 50float), 8kg/ ( 65 float above)0.6~1.025IP65, IP66, IP67, IP68EX ia IIC T6 for PR-30EX and EX d IIC T6 for PR-30EXD
1.2A 200VDC(SPST), 2.5A 250VDC(SPST), 1A 200VDC(SPDT).sus 316sus 304sus 304ALDC 8, sus 304
SPST, SPDT, DPDT(option)
Operating temperatureDesign pressure
Process medium S.G.IP rating
Protection type
Switch output
Switch rating
Material
FloatFlange
Guide pipeHousing
CONTACT TYPE : SPDTAll switches have three electric connections(black, blue,red)The black wire is the common pole for both switchingfunctions (black contact and make contact)
CONTACT TYPE : DPDTThis switch has two(2) SPDTcontact which is same as above.
PR-30S-2
PR-30S (with test device)
PR-30S-2 (with chamber)
PR- 30S ���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
-���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
: With chamber: No housing: Submergible type: Interface Detector
C
SI
N
Q’ Ty of float: 1 Float: 2 Float: 3 Float
23
1
PR- 30EXD ���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
-���
�������������������������������������������������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� ������� �������������������������������������������������
�
: With chamber: No housing: Submergible type: Interface Detector
C
SI
N
Q’ Ty of float: 1 Float: 2 Float: 3 Float
23
1
(OPERATING SIGNAL)
60 61PANASIA CO..,LTD.
Reed Switch TypeFloat Level Switch
PR-30EXD-1 PR-30S-1N PR-30S-2N
Contact Protection RequirementsWhen switching inductive loads such as relays, solenoids and transformers, reed switch contents require protection in orderto ensure long, dependable life. when current is interruped, the inductance or electrical inertia of the load generates a largefrequency voltage, which appears across the switch contacts. If the voltage is large enough, it can break down the mediumin the gap between them, making a conductive path. this phenomenon, called arcing is the spark you see. Arcing can cause the contacts to burn, weld together or stick; thus, giving unreliable performance. The purpose of protection circuits is to prevent arcing, by shorting this voltage through an alternate path.
Recommended ProtectionD.C.A 1N4004 diode(or equivalent) connected cathode-to-positive, as shown in Figure 1, is recommended. The diode does not conduct when the load is energized, but conduts and shorts out the generated voltage when the switchopens. The generated voltage always acts in series with the applied voltage.A.C.A resistor and capacitor, connected in parallel with the switch, as shown in Figure 2, is recommended. The capacitor is ahight impedance to 60hertz, but is essentially a short circuit high prequencies of generated voltages.Transient suppressors or varistors may also be used to dissipate the transient and protect the switch contacts. For130VAC rated devices, the following table may be used for selection.
Flgure 1D.C ContactProtection(Drain the load)
Flgure 2A.C ContactProtection(Protect the s/w)
Drain the Load
Protection switch
PR-30S-1C (With chamber / IP67)
62 63PANASIA CO..,LTD.
Electric Indicator
Dimension
Bargraph Type
Digital Indicator
Dimension
Electric Indicator Digital Indicator
ModelSize
Mounting methodInput
Internal resistanceAccuracy
Measuring rangeIndicating angle
WeightOperating temperature
ColorApplication
PAI-100A110X110 SquarePanel front mountingDC 4~20mA1.5
1.5% F.SAT 200~100%(Standard)250deg.450g0 to +40BlackPanel and local gauge box
Specifications Specifications
Specifications
Specifications
�
ModelSize
Mounting methodInput
AccuracyScale length
Case materialWeight
Finish ColorApplication
Black or whitePanel and local gauge box
Contact
SK-130-C30 X 100Panel front mountingDC 4~20mA
1.0% 100mmResinApprox. 1.3kgOn-alarm type, offalarm Typeavailable for special specification
ModelAccuracy
ScaleHeightVolume
DigitOutput
Alarm pointHHHLLL
MaterialPower
TemperatureWeight
PAI-4000(Vertical type)1% of F.S
%Display dual mode.(level & volume)%DisplayMax. 16 Gradient %DisplayA) DC 4~20mA(1-5V) or variable resistanceB) RS-4854DigitAlarm contact, RS4852point, 4point (option)Dry contact normal open or close (option)Dry contact normal open or closeDry contact normal open or closeDry contact normal open or close (option)ABSDC24V, 6W(MAX.)0 ~501.0kg
Input
Input SignalRange
Power SupplyAccuracy
Ambient TempModelWeight
Setting Press
DC 4~20mA-0.1~+0.3bar(Free Scale)DC 24VDISPLAY ONLY(SENSOSR : 0.3% of F.S)-0 ~50ESDB4250g High press:+0.22 bar, Low press: -0.05 bar
�
Class Approvals
RADAR BEAM TYPECARGO MONITORING SYSTEM
MAGNETIC FLOAT TYPECARGO MONITORING SYSTEM
HIGH & OVERFILLALARM SYSTEM
VALVE REMOTECONTROL SYSTEM
AIR PURGE TYPE /ELECTRIC PNEUMATIC TYPELEVEL GAUGING SYSTEM
ELECTRIC PRESSURE TYPELEVEL TRANSMITTER
WATER INGRESS ALARMSYSTEM
LEVEL GAUGE-Self power content gauge-Flat type glass level gauge-Magnetic float type level gauge
LEVEL SWITCHES-PM-12 Series-PM-90 Series-PR-30 Series
CLASS
KRS ABS BV DNV LRS NK GL RINA CCS
ClassificationSociety
Products
64 65PANASIA CO..,LTD.
World Wide Service Network
Maintenace / Parts Supply / Repaire / Technical Support
http://www.worldpanasia.com> >
AMERICANew JerseyHouston, TaxasRio De Janeiro, Brazil
EUROPERY, DenmarkRotterdam, The NetherlandsSurrey, EnglandGenova, ItalyPiraeus, GreeceIstanbul, TurkeyLisbon, PortugalLimmasol, CyprusVladivostok, Russia
MIDDLE EASTDubai U.A.EOman
ASIABusan, KoreaNagasaki, JapanDalian, ChinaShanghai, ChinaGuangzhou, ChinaHanoi, VietnamKuala Lumpur, MalaysiaSingaporeJakarta, IndonesiaKaohsiung, TaiwanCochin, India