52
SimXpert 2010 Installation and Operations Guide

SimX 2010 Installation

Embed Size (px)

DESCRIPTION

The MSC SimXpert Installation and Operations Guide will provide detailed instructions on how to install and configure MSC SimXpert 2010.Information contained in this document includes: * Required Hardware and Software Configurations * Memory and General Requirements * Installaton on Windows and Linux Operating Systems

Citation preview

Page 1: SimX 2010 Installation

SimXpert 2010

Installation and Operations Guide

Page 2: SimX 2010 Installation

CorporateMSC.Software Corporation2 MacArthur PlaceSanta Ana, CA 92707 USATelephone: (800) 345-2078Fax: (714) 784-4056

EuropeMSC.Software GmbHAm Moosfeld 1381829 Munich, GermanyTelephone: (49) (89) 43 19 87 0Fax: (49) (89) 43 61 71 6

Asia PacificMSC.Software Japan Ltd.Shinjuku First West 8F23-7 Nishi Shinjuku1-Chome, Shinjuku-KuTokyo 160-0023, JAPANTelephone: (81) (3)-6911-1200Fax: (81) (3)-6911-1201

Worldwide Web www.mscsoftware.com

Disclaimer

MSC.Software Corporation reserves the right to make changes in specifications and other information contained in this document without prior notice.

The concepts, methods, and examples presented in this text are for illustrative and educational purposes only, and are not intended to be exhaustive or to apply to any particular engineering problem or design. MSC.Software Corporation assumes no liability or responsibility to any person or company for direct or indirect damages resulting from the use of any information contained herein.

User Documentation: Copyright 2010 MSC.Software Corporation. Printed in U.S.A. All Rights Reserved.

This notice shall be marked on any reproduction of this documentation, in whole or in part. Any reproduction or distribution of this document, in whole or in part, without the prior written consent of MSC.Software Corporation is prohibited.

This software may contain certain third-party software that is protected by copyright and licensed from MSC.Software suppliers. Portions of this software are owned by UGS Corp. Copyright 1997. All Rights Reserved. Portions of this software are owned by Spatial Corp. 1986-2002. All Rights Reserved.

The MSC.Software logo, MD Nastran, MSC, MSC Nastran, MD Adams, Adams, Patran, SimDesigner, SimManager, SimEnterprise, and SimXpert are trademarks or registered trademarks of the MSC.Software Corporation in the United States and/or other countries.

Page 3: SimX 2010 Installation

NASTRAN is a registered trademark of NASA. CATIA is a registered trademark of Dassault Systemes, SA. LS-DYNA is a trademark of Livermore Software Technology Corporation. Parasolid® is a registered trademark of UGS Corp. All other brand names, product names or trademarks belong to their respective owners.

Version Number: SIMX*2010*Z*Z*Z*DC-OPS

Page 4: SimX 2010 Installation
Page 5: SimX 2010 Installation

Installation and Operations GuideIntroduction

Page 6: SimX 2010 Installation

SimXpert Installation and Operations GuideIntroduction

2

IntroductionThe MSC SimXpert Installation and Operations Guide will provide detailed instructions on how to install and configure MSC SimXpert 2010.

The guide is intended to assist System Administrators through the installation of MSC SimXpert 2010.

The installation instructions are drafted, assuming that you have basic administration knowledge of the

operating system you are working on.

Root or Administrator level privileges are required to perform the installation of MSC SimXpert 2010

and its components.

Organization Of This GuideThe Guide is organized into the following chapters:

• Required Hardware and Software Configurations

• Installing on Microsoft Windows

• Installing on Linux

Page 7: SimX 2010 Installation

3 IntroductionOverview of the SimXpert System

Overview of the SimXpert SystemSimXpert uses the FLEXlm licensing system. FLEXlm functions as a stand-alone nodelock license server or as a distributed license system. For other issues and questions, please consult the Acresso documentation at their web site, www.acresso.com.

The SimXpert software system consists of several components:

• The core SimXpert pre- and postprocessor,

• The CDE database system,

• SimXpert workspaces,

• The FLEXlm licensing system, and

• The on-line help system.

The name SimXpert refers both to the pre- and postprocessing components, and to the system as a whole.

SimXpert Pre- and PostprocessorSimXpert is an interactive, multi-discipline simulation environment with integrated solvers and Enterprise Compute connectivity. All pre- and postprocessing, translation, and solver capabilities are accessed from within this graphical environment.

Online DocumentationThe SimXpert HTML Help system is a hybrid JAVA/JAVA Script Help system that will be displayed in the SimXpert environment. On Unix systems you may select to view the help system in a standalone browser, we recommend that you use Firefox 1.5 or later.

To specify a desired standalone browser on Unix systems, use the variable MSC_SX_HELPBROWSER. If this is set, the value indicates which executable to start as the help browser. In case starting that executable fails, an error message is printed to the standard error stream. The default value is "mozilla". Example: setenv MSC_SX_HELPBROWSER firefox.

Page 8: SimX 2010 Installation

SimXpert Installation and Operations GuideOverview of the SimXpert System

4

Page 9: SimX 2010 Installation

Required Hardware and Software Configurations

Page 10: SimX 2010 Installation

SimXpert Installation and Operations GuideMemory and General Requirements

6

Memory and General RequirementsThe following table shows the memory and disk space requirement for the SimXpert. SimXpert may actually run with fewer resources than shown, but we recommend these minimums for practical use.

Operating SystemSystem Patches Disk Space Memory and Swap Space

Microsoft Windows 7 Enterprise and Ultimate Editions (x32)

None 4-5 GB 2 GB Minimum 3 GB RecommendedSwap = 3-4.5 GB

Microsoft Windows Vista Enterprise and Ultimate Editions (x32)

SP1, SP2 4-5 GB 2 GB Minimum 3 GB RecommendedSwap = 3-4.5 GB

Microsoft Windows XP Professional (x32)

SP2, SP3 4-5 GB 1 GB Minimum3 GB RecommendedSwap = 1.5-4.5 GB

Microsoft Windows 7 Enterprise and Ultimate Editions (x64)

None 4-7GB 2 GB Minimum 4 GB (or higher) RecommendedSwap = 3-6 GB

Windows Vista Enterprise and Ultimate Editions (x64)

SP1, SP2 4-7 GB 2 GB Minimum 4 GB (or higher) RecommendedSwap = 3-6 GB

Microsoft Windows XP Professional (x64)

SP1, SP2 4-7 GB 2 GB Minimum 4 GB (or higher) RecommendedSwap = 3-6 GB

Red Hat Enterprise Linux 4 (x86-32)

U3, U4 4-5 GB 1 GB Minimum 3 GB RecommendedSwap = 1.5-4.5 GB

Red Hat Enterprise Linux 5 (x86-32)

U3 4-5 GB 1 GB Minimum 3 GB RecommendedSwap = 1.5-4.5 GB

Red Hat Enterprise Linux 4 (x86-64)

U3, U4 4-7 GB 2 GB Minimum 4 GB (or higher) RecommendedSwap = 3-6 GB

Red Hat Enterprise Linux 5 (x86-64)

U3 4-7 GB 2 GB Minimum 4 GB (or higher) RecommendedSwap = 3-6 GB

Page 11: SimX 2010 Installation

7 Required Hardware and Software ConfigurationsMemory and General Requirements

SimXpert memory requirements vary according to model size and actions performed. Solvers or other software that run concurrently with SimXpert may increase RAM, swap (also referred to as paging or virtual memory), and disk space requirements. The following guidelines are based on typical use.

RAM and Swap GuidelinesRAM memory is much faster than disk-based swap memory, increasing the amount of RAM typically improves performance. Memory in this context is the sum of physical RAM and paging (swap) space.

Note: SimXpert could possibly generate memory, “memalloc,” errors when it is unable to obtain sufficient memory.

Page 12: SimX 2010 Installation

SimXpert Installation and Operations GuideMicrosoft Windows Requirements

8

Microsoft Windows RequirementsSimXpert supports the following Microsoft Windows Vista and XP hardware and software. For additional information on SimXpert on Windows support and limitations see Installing on Microsoft Windows.

Tested SystemsMSC has tested SimXpert on the following computer systems:

• Compaq Professional Workstation w4000, w6000, w8000, Compaq N800c, N800w Laptop

• Dell Workstation 410, 610, 220, 420, 470, 620, 330, 340, 350, 360, 370, 380, 390, 450, 470, 530, 650, 670, 690, T3400, T3500, T7400, and M50, M60, M70, M90, M4300 Laptops

• HP Visualize NT (p- and x-class), xw3100, xw4000, xw4100, xw4200, xw4300, xw4400, xw4550, xw4600, xw5000, xw6000, xw6200, xw6600, xw8000, xw8200, xw8400, xw8600, xw9300, xw9400, mw8240, nw8440, Z400, Z800, nw9440, 8510w, 8530w, 8540w, 8710w, 8730w, and 8740w Laptops

• IBM IntelliStation Z-Pro, M-Pro, E-Pro, A-Pro

• Sun Opteron W2100z, Ultra 20, 40.

Graphics Boards and OpenGL AccelerationAny graphics board that has a driver for Windows XP, Vista, or Windows 7 and 1280x1024 or greater resolution should function with SimXpert. SimXpert uses standard native OpenGL acceleration and

Windows Requirements

Hardware Platforms Intel Pentium 4, Pentium D, Core Duo, Core 2 Duo, and AMD Opteron

Operating Systems Windows 7 Enterprise and Ultimate Editions (x32 and x64), Windows Vista Enterprise and Ultimate Editions (x32 and x64, Service Packs 1 and 2), Microsoft Windows XP Professional (Service Packs 2 and 3), XP Professional x64 (Service Packs 1 and 2).

Compiler Versions Microsoft .NET 2005 SP1 (Version 8.0.50727.762), Microsoft .NET Framework Version 2.0.50727, and Intel Fortran version 10.1.024

Compiler Versions- x64 Microsoft .NET 2005 SP1 (Version 8.0.50727.762), Microsoft .NET Framework Version 2.0.50727, and Intel Fortran version 10.1.024

Other 3 Button Mouse

Graphics Devices 1280x1024 or higher resolution (see Graphics Boards and OpenGL Acceleration, 8)

Important: SimXpert does not support Microsoft Windows running on Intel Pentium 3, Intel Itanium or Itanium 3 workstations.

Page 13: SimX 2010 Installation

9 Required Hardware and Software ConfigurationsMicrosoft Windows Requirements

should benefit from any OpenGL acceleration such a graphics card provides. MSC.Software recommends using a native OpenGL graphics card. MSC.Software has, however, tested the following specific graphics adapters to verify compatibility with SimXpert on Windows. We cannot guarantee the functionality of other graphics devices.

• 3D Labs Wildcat IV 7110, 7210, Realizm 100, 200, 5001, 800

• ATI Fire GL E1/X1/Z1, FireGL V7600, V7700, 8700, 8800, Mobility Radeon FireGL T2-64, T2-128, X2-256, X3-256, V3100, V3350, V3600, V5000, V5100, V5200, V5600, V7100, V7200, V7300, V7350, Mobility V5600, 5700, 5725, FirePro V3700, V3800, V4800, V5700, V5800, V7750, 7820

• Hewlett-Packard FX5+, FX10+

• NVidia Quadro2 EX, Quadro4 700XGL/750XGL/900XGL/980XGL, Quadro4 500/700 GoGL (M50/M60 Laptop), 360m, 570m, 1500m, 1600m, 2500m, FX285, FX 370, FX330, FX350,

FX360, FX500, FX540, FX550, FX560, FX570, FX600, FX10002, FX1100, FX1300, FX1400,

FX1700, FX3000, FX3400, FX3450, FX3500, FX40003, FX4400, FX4500, FX4600, FX5500, FX5600, FX4800, FX5800, FX3700, FX3700m, FX2700m, FX770m, FX380, FX580, FX1800, FX3800

Note: Not all graphics cards tested on all OS levels.

1When using the 3D Labs Realizm 500 graphics card, driver 4.5.794.0 is required.2When using the NVidia Quadro FX1000, the 7.1.8.4 driver needs to be used.3When using the NVidia I SV RC graphics drivers on Windows XP use NVidia graphics drivers 56.* or

older, or 67.20, or 71 and newer.

Page 14: SimX 2010 Installation

SimXpert Installation and Operations GuideLinux Requirements

10

Linux RequirementsSimXpert supports the following Linux hardware and software.

Tested SystemsMSC has tested SimXpert for Linux on the following computer systems:

• Dell Workstation 220, 420, 620, 330, 340, 350, 360, 450, 530, 650

• HP Visualize NT (pL- and xL-class), x-class, xw 4200, xw 4700, xw6200, xw8200, xw9300

• IBM IntelliStation

• Sun W1100z, W2100z

SimXpert and MD Nastran on Linux should run on any Intel-based PC that is compatible with one of the supported versions of Linux. For the system tests noted above, the amount of RAM ranged from 512 MB to 2 GB.

Linux Requirements

Hardware Platforms Intel Pentium 4, Pentium D, Core Duo, Core 2 Duo, and AMD Opteron

Operating System Red Hat Enterprise Linux 4 Update 3 and Update 4 (x86-32, x86-64)*, Linux 5 Update 3 (x86-32, x86-64)

* SimXpert may run on Linux versions other than those listed if the same Linux kernel is used. MSC.Software does not, however, test other versions of Linux, and can neither support other versions nor make any guarantees of compatibility.

Motif Version Open Motif 2.2.3†

† SimXpert for Linux requires Motif 2.2 to run. Open motif rpm files are currently not available from either Red Hat or SuSe. They can be downloaded free of charge from http://www.openmotif.org/download. MSC has certified that open motif version 2.2.3-2 works correctly for SimXpert.

Compiler Version Intel C/C++ version 9.1.045 and Intel Fortran, version 10.1.017

Compiler Version x64 Intel C/C++ version 9.1.045 and Intel Fortran, version 10.1.017

Window Manager KDE 3.0, Gnome (Enlightenment)

3D Graphics Library Version Must install vendor supplied OpenGL video driver.

Other Linear Algebra Pack (lapack) is required for use by Python numpy and scipy libraries.

3 Button Mouse

Graphics Devices 1280x1024 or higher Graphics Card (see below)

Page 15: SimX 2010 Installation

11 Required Hardware and Software ConfigurationsLinux Requirements

Graphics Boards and OpenGL AccelerationMSC.Software recommends using a native OpenGL graphics card. SimXpert uses standard native OpenGL acceleration and should benefit from any OpenGL acceleration that a graphics card provides. Any graphics board that has a driver for Linux, and 1280x1024 or greater resolution should function with SimXpert. MSC.Software has tested the following graphics adapters to verify compatibility with SimXpert on Linux.

• FireGL 8700/8800, FireGL X1

• NVidia FX500, FX1100, FX1300, FX3000, FX3400, FX3450, FX3700, FX4000

• Wildcat 7210

Note: Not all graphics cards tested on all OS levels.

Page 16: SimX 2010 Installation

SimXpert Installation and Operations GuideLinux Requirements

12

Page 17: SimX 2010 Installation

Installing on Microsoft Windows

Page 18: SimX 2010 Installation

SimXpert Installation and Operations GuideOverview

16

OverviewMSC SimXpert 2010 can be installed on Microsoft Windows using an interactive installation Wizard. This section describes the use of that installation utility as well as additional steps that may be required for modules and external programs.

Note: SimXpert has directories that go many levels deep. If you install SimXpert in a directory below the root, it is possible that you will exceed the directory length limit. Therefore, we recommend installing in the default location. Any disk drive can be used.

Page 19: SimX 2010 Installation

17 Installing on Microsoft WindowsInstallation Pre-requisites

Installation Pre-requisites1. Log in and exit all Windows programs. In general, you do not need administrator privileges to

install SimXpert except as follows:

• You must have permission to create the installation directory. You may need administrator privilege to grant this permission.

• Installing the FLEXlm License Server requires administrator privilege.

• To create installations visible by other users.

• To utilize file association option.

2. If you are downloading from the Solutions Download Center, download the self-extracting archive (.exe) and follow these steps:

• Copy the self-extracting archive (.exe) file to a temporary subdirectory with enough disk space. Make a note of this location.

• Click on the files to start install shield (product installer). For the remainder of the installation process, follow instructions in the product installation guide. You may remove temporary files from the subdirectory created in the step above.

Installing from the DVDFollow these steps to install SimXpert from DVD:

1. Insert the MSC SimXpert installation DVD into the optical drive of your computer and follow any one of the following step:

• If Autorun window appears then the user need to select the ‘Open Folder to View Files’ option and run setup.exe

• If installation does not start automatically then select Run from the Start menu. You should see the following dialog box on your screen.

Page 20: SimX 2010 Installation

SimXpert Installation and Operations GuideInstallation Pre-requisites

18

2. Type x:\setup.exe and click OK, where x is your media drive. This begins the SimXpert installation Setup Wizard. Setup attempts to verify the resources necessary to run SimXpert on Windows then opens the main setup window.

3. Select the type of installation. Click the Browse button to change the location of the MSC SimXpert installation.

Page 21: SimX 2010 Installation

19 Installing on Microsoft WindowsInstallation Pre-requisites

4. In case you selected User Selectable in the previous step, you need to select the MSC SimXpert components that you want to install. Every component is described in the Description box. Click Next after you have made your choices.

Page 22: SimX 2010 Installation

SimXpert Installation and Operations GuideInstallation Pre-requisites

20

5. Enter License information and click Next.

Page 23: SimX 2010 Installation

21 Installing on Microsoft WindowsInstallation Pre-requisites

6. You will then be prompted to choose the scratch directory to be used by MD Nastran for its analyses. If the Scratch directory is deleted, Nastran will not run and will not prompt any error.

7. Click Yes to create MSC SimXpert icons on the desktop.

8. Configuring SimManager within SimXpert

Page 24: SimX 2010 Installation

SimXpert Installation and Operations GuideInstallation Pre-requisites

22

If you have MSC SimManager installed in your enterprise, click Yes to specify the client configuration. Click No if you do not have SimManager installed..

First the appropriate protocol (http or https) and the host name of the server on which MSC SimManager is running is entered.

A SimManager server could be running multiple Web Portals. A unique port number along with the name of the portal needs to be entered

9. CATIA settings need to be configured to enable direct access to CATIA geometry. An appropriate version of CATIA (32-bit or 64-bit) compatible with the operating system is required.

Page 25: SimX 2010 Installation

23 Installing on Microsoft WindowsInstallation Pre-requisites

Click Yes to specify CATIA configuration settings. Click No to skip this step.

10. Next, the installer requests the location of the Catia installation directory

Page 26: SimX 2010 Installation

SimXpert Installation and Operations GuideInstallation Pre-requisites

24

11. You can also access Pro/ENGINEER Wildfire geometry using SimXpert. To unable this access, Pro/ENGINEER must be installed on the same computer as SimXpert.

Click Yes to provide Pro/ENGINEER settings. Click No to skip this step.

12. Select the Pro/ENGINEER Wildfire version you have installed. Click Next.

Page 27: SimX 2010 Installation

25 Installing on Microsoft WindowsInstallation Pre-requisites

13. Specify the folder where Pro/ENGINEER Wildfire is installed. Click Next.

Page 28: SimX 2010 Installation

SimXpert Installation and Operations GuideInstallation Pre-requisites

26

The SimXpert for Pro/ENGINEER shortcut will be placed on the desktop. You may use this shortcut to use SimXpert with Pro/ENGINEER. At other times, you may use the MSC SimXpert desktop shortcut

If you do choose to configure these settings, the installer will prompt you for the version of the UGS NX installation:

Page 29: SimX 2010 Installation

27 Installing on Microsoft WindowsInstallation Pre-requisites

Next, the installer requests the location of the UGS NX installation directory:

Page 30: SimX 2010 Installation

SimXpert Installation and Operations GuideInstallation Pre-requisites

28

14. Installing CADNexus

If a 'Complete' installation was chosen or the 'SimXpert Native CAD Access Component' was selected for a 'User Selectable' installation, you will see the following dialog box at the end of the SimXpert installation process:

You will be asked to provide the location of the CADNexus installation media:

Page 31: SimX 2010 Installation

29 Installing on Microsoft WindowsInstallation Pre-requisites

Configuring CATIA with SimXpert

SGM-Capri(CATIA)

SGM-Capri (CATIA) is another SGM SCA component that can be optionally turned on for Native CAD attach in SimXpert 2010. By default, SGM-CATIA component is used by SimXpert in order to access NATIVE CATIA models (parts and assemblies). The configuration details are as follows

• SGM-Capri can be turned on by setting USE_SGM_CATIA =0 environment variable before starting SimXpert.

• No environment variable should be set for using default SGM-CATIA component.

• SGM-Capri (CATIA) component requires installation of CADNexus bits at the end of SimXpert installation. This module is supplied as part of SimXpert installation.

The following is supported by SGM-Capri (CATIA):

• SGM-Capri (CATIA) supports Native CAD attach of CATIA parts and assemblies in SimXpert.

• In addition to topologies and geometries, this component provides access to Features and Parameters in the CATIA part files.

Page 32: SimX 2010 Installation

SimXpert Installation and Operations GuideInstallation Pre-requisites

30

• Features are accessed and displayed in SimXpert Model Browser using feature names originally assigned in CATIA.

• Feature parameters can be modified and model regeneration can be performed from within SimXpert application.

• Access to parameters is limited to only those parameters that are attached to a feature.

• SGM-Capri (CATIA) also supports update of SimXpert CAD model with EXTERNAL MODEL changes done in CATIA application.

• The functionality is referred to as SmartUpdate of CAD model that is already accessed in SimXpert.

• SimXpert Smartupdate functionality will update the CAD topologies, geometries, features and parameters.

• In addition to updating the CAD entities, SmartUpdate will also trigger a mesh update of any associated meshes (if the CAD model had a mesh associated with it prior to a SmartUpdate).

• SmartUpdate will also trigger a LBC update of any associated loads and boundary conditions so the LBCs can be reapplied to entities automatically after a CAD model update.

Changes in CAD model due to SmartUpdate are summarized using groups of modified entities within SimXpert. The following is the message window output from a SmartUpdate operation.

There are several identified gaps between SGM-Capri (CATIA) and SGM-CATIA components in SimXpert 2010. These gaps include among others hard-geometry association, KP-parameter access and update, and Model Browser Tree differences.

Configuring SolversTo configure which version of Nastran is used by SimXpert you will need to modify entries in the simxpert.config.bat and SimXpertNastran.config files. These files are located in install_dir\SimXpert_version#\operating_system\bin, for example: C:\MSC.Software\SimXpert\2010\WINNT\bin

Page 33: SimX 2010 Installation

31 Installing on Microsoft WindowsInstallation Pre-requisites

Statements need to be modified as follows:

simxpert.config.bat

IF NOT DEFINED MSCP_LOCAL_NASTRAN_CMD2004 (set MSCP_LOCAL_NASTRAN_CMD2004=path\bin\mdnastran.exe

)

IF NOT DEFINED MSCP_NASTRAN_CMD2004 (set MSCP_NASTRAN_CMD2004=path\bin\mdnastran.exe

)

SimXpertNastran.config

NASTEXE=path\bin

NASTEXE_2005=path\bin

Where path is the Nastran installation folder, for example: C:\MSC.Software\MD_Nastran\2010

Patran Database ImportSimXpert has the ability to import a Patran database. Following are the requirements to import Patran Database:

• This requires an installation of Patran with the same version as the database that will be imported.

• The environment variable “MSC_SX_PATRAN_HOME” should be set to the path to the home directory. An example path is:

C:\MSC.Software\MD_Patran\2010.

• The Analysis preference of the Patran database must be set to MD or MSC.Nastran, and the model must have finite elements with properties assigned.

MSC.Licensing Installation (Optional)SimXpert on Windows XP uses FLEXlm based licensing. If you already have FLEXlm setup as a license server for SimXpert, then you do not need to install FLEXlm.

You will need to have a FLEXlm server on your Windows workstation or on a UNIX workstation on the same TCP/IP network.

Follow these steps to install FLEXlm:

1. Go to Setup Wizard.

2. Select MSC.Licensing from the main menu, the following dialog box appears.

Page 34: SimX 2010 Installation

SimXpert Installation and Operations GuideInstallation Pre-requisites

32

3. Click Yes to proceed with Sever Installation.

4. Server Install installs the FLEXlm server. The Setup Wizard will prompt you for an existing license.dat file (supplied by MSC), and will start the appropriate Windows services.

FLEXlm licensing models and examples

MSC SimXpert uses one of the following FLEXlm licensing models:

• Named User licensing

The license provided by MSC Software for SimXpert 2010 authorizes a maximum number of users the ability to run SimXpert. Your SimXpert administrator manages the list of users that can run the software. Any Named user may log in and use SimXpert on any machine on the network on which the license server is reachable. When individual users consume multiple licenses, it is possible for the available license pool to be depleted, therefore denying access to other named users.

• OPTIONS file

The OPTIONS file contains the list of Named users of SimXpert. Your administrator maintains the OPTIONS file that lists the Named user login IDs. This way, you control who is a Named user and may change who is a Named user at any time. This is done by editing the file and restarting the license server using the FlexLM lmtools utility. No contact with MSC Software is needed to change the list of Named users.

Named user licensing requires that the path to the OPTIONS file be given on the DAEMON line. Please refer to FlexLM regarding various ways of creating an option file. Some examples are listed below:

Note: It is highly recommended that you first acquire authorization codes from MSC.

# ------ Start of License File ------#SERVER test 00137222cf 1700DAEMON MSC C:\MSC.Software\MSC.Licensing\10.8\msc OPTIONS=C:\your_named_user_options_fileFEATURE SimXpert_Base MSC 2007.1018 18-oct-2007 2 \ 3DF5E3B2324641CD2145 ISSUED=18-oct-2006 ck=221 \ SN=1278576-f3f3b558c2772cfcba1dFEATURE SimXpert_WS_Structures MSC 2007.1018 18-oct-2007 2 \ 3DD5E34272E61847BDAB USER_BASED ISSUED=18-oct-2006 ck=72 \ SN=778626-b1ac16653e9e88d620aa

Page 35: SimX 2010 Installation

33 Installing on Microsoft WindowsInstallation Pre-requisites

All SimXpert features except SimXpert_Base need to be included in the options file. Sample options files follow:

Example 1:

Example 2:

• Nodelocked

Allows use of MSC SimXpert only on a specifically named machine.

Following is an example of a nodelocked license file:

SERVER hostname hostid 1700

DAEMON MSC /your_path/msc

FEATURE V5i_Access MSC 2004.0531 29-apr-2004 8 4CFEF76D59E040FC1343 \

HOSTID=23456789 asset_info="10081+10084 AP209 Gateway (GWS)" \

ISSUED=29-apr-2003 ck=54 SN=1324476-7b13e038600a2cfcb952

FEATURE CA_Gen_NASTRAN MSC 2004.0531 29-apr-2004 1 \

0CCEA79DA1987474CE48 HOSTID=23456789 \

asset_info="10081+10054+1003 MSC.Nastran Generative (GPN)" \

ISSUED=29-apr-2003 ck=48 SN=985526-7cfae6677b9688d67940

• Concurrent

INCLUDE SimXpert_WS_Crash USER user1INCLUDE SIMX_Crash_Solver USER user1INCLUDE SimXpert_WS_Motion USER user1INCLUDE SimXpert_WS_Structures USER user1INCLUDE SIMX_Structures_Solver USER user1

GROUP simxuser user1 user2INCLUDE SimXpert_WS_Crash GROUP simxuser INCLUDE SIMX_Crash_Solver GROUP simxuser INCLUDE SimXpert_WS_Motion GROUP simxuser INCLUDE SimXpert_WS_Structures GROUP simxuser INCLUDE SIMX_Structures_Solver GROUP simxuser INCLUDE SimXpert_WS_Thermal GROUP simxuser INCLUDE SIMX_Thermal_Solver GROUP simxuser INCLUDE SIMX_Crash_Solver_DMP GROUP simxuser INCLUDE SIMX_CATDirect GROUP simxuserINCLUDE SIMX_CATDirect_V5 GROUP simxuserINCLUDE SIMX_ProE_Access GROUP simxuserINCLUDE SimXpert_Geometry_Modeling GROUP simxuserINCLUDE SimX_ST_NL_Solver GROUP simxuser

Page 36: SimX 2010 Installation

SimXpert Installation and Operations GuideInstallation Pre-requisites

34

Allows multiple uses of MSC SimXpert according to the number of licenses purchased.

Following is an example of a concurrent license file:

SERVER hostname hostid 1700

DAEMON MSC /your_path/msc

FEATURE CA_Access MSC 2004.0531 29-apr-2004 16 CC3E474D769449F91144 \

asset_info="10081+10084 AP209 Gateway (GWS)" \

ISSUED=29-apr-2003 ck=96 SN=1324476-57778154941b2cfc1719

FEATURE CA_Gen_NASTRAN MSC 2004.0531 29-apr-2004 2 \

9C6EA7FD88D85842DEFB asset_info="10081+10054+1003 MSC.Nastran \

Generative (GPN)" ISSUED=29-apr-2003 ck=167 \

SN=985526-5a231d9776d588d6df96

Page 37: SimX 2010 Installation

35 Installing on Microsoft WindowsSilent Installation

Silent InstallationThe SimXpert installation supports silent installations, which run in the background with no graphical interface or interaction with the desktop. Installations running in Silent mode rely on a pre-configured answer file to do the installation. Silent installations are generally used in a batch manner to facilitate installation on many machines on a network.

Creating the Answer fileTo create the answer file you need to run the SimXpert installation in normal (GUI) mode with a special switch which instructs the installation to record all of your answers in a specified answer file. Here is an example of the command:

z:\setup.exe -r [-f1"c:\location\filename"]

The command assumes that the installation program is being executed from the SimXpert DVD-ROM mounted on drive z:, the "-r" switch instructs it to generate the answer file and the optional "-f1" switch specifies the location and name of the answer file. (The brackets around the "-f1" switch indicate that it is optional. You do not need to type the brackets.) If the -f1 switch is not specified, the answer file will be created as follows:

c:\windows\setup.iss

Running the Silent mode installationTo run installation in silent mode use the “-s” switch and specify the answer file in this manner:

z:\setup.exe -s -f1"c:\location\filename"

Note: In the example above, the f1 is the number one, not an L.

Page 38: SimX 2010 Installation

SimXpert Installation and Operations GuideSilent Installation

36

Page 39: SimX 2010 Installation

Installing on Linux

Page 40: SimX 2010 Installation

SimXpert Installation and Operations GuideOverview

36

OverviewSimXpert on Linux uses an interactive installation Wizard. This section describes the use of that utility as well as additional steps which may be required for modules and external programs.

Note: SimXpert has directories that go many levels deep. If you install SimXpert in a directory below the root, it is possible that you will exceed the directory length limit. Therefore, we recommend installing in the default location. Any disk drive can be used.

Page 41: SimX 2010 Installation

37 Installing on LinuxCreating a New Installation

Creating a New InstallationFollow these steps to install SimXpert on Linux:

1. Login as root. In general, you do not need administrator privileges to install SimXpert except as follows:

• You must have root permission to create the /msc installation directory. If you do not have administrator privilege, you can install SimXpert in any directory where you have write permission.

• Installing the FLEXlm License Server requires administrator privilege.

2. Mount the SimXpert on Linux media.

3. Type /CDROM/setupLinux.bin. This begins the SimXpert on Linux installation Setup Wizard.

Installing using Downloaded FilesFollow these steps to install SimXpert using downloaded files

1. Login as root.

2. “cd” to a temporary directory with adequate disk space to store the download. Create a subdirectory and “cd” into the subdirectory.

3. Download the delivery file from Solution Download Center. If you previously downloaded the file please proceed to step 5.

4. Extract the delivery file into current subdirectory:

• tar –xf Delivery_File

5. Execute the install.script (./mscsetup or unixinst or … ) and follow the instructions in the product installation guide for the remainder of the installation process.

The SimXpert media will automatically mount if autofs is present and configured properly. If it does not, try one of the following commands:

# mount /mnt/cdrom

# mount /dev/cdrom

LINUX provides a “user” option for mounting that allows non-root users to mount media. This option prohibits direct execution of media resident files. If when attempting to execute the installation you receive a “Permission Denied” error, you must remount the media with the following command:

# mount -o exec /mnt/cdrom

Page 42: SimX 2010 Installation

SimXpert Installation and Operations GuideCreating a New Installation

38

6. Executing the installation script may require adding execution privilege:

• chmod +x install.script

7. Cleanup: After installation is complete you may remove the subdirectory created in Step 2 above.

If there are multiple tar files, follow these steps for Linux systems:

1. Extract tar files into separate directories (media.inf and setup exist in all tar archives).

2. If /tmp does not contain enough space and you get a "no space left on device error" use tmpdir option. For example,setupHP11.bin -is:tempdir /disk2/scratch.

3. Remove the ~/InstallShield, /tmp/ist* and /tmp/ism* directories after the installation.

SimXpert InstallationFollow these steps to install SimXpert on your system:

1. Choose the directory where you want to install SimXpert. You must have root privileges to install SimXpert in the /msc directory.

Page 43: SimX 2010 Installation

39 Installing on LinuxCreating a New Installation

2. Choose whether to perform a 'Complete' or 'User Selectable' installation.

3. For the 'User Selectable' installation, confirm which features you would like to install and click Next. If the disk on which you are installing SimXpert does not have enough space, you will receive a warning message and the installation will stop.

Page 44: SimX 2010 Installation

SimXpert Installation and Operations GuideCreating a New Installation

40

4. At the end of the installation, the following Licensing information dialog box appears. Specify the location of the license manager, or click Next and set it later with the help of system administrator.

Page 45: SimX 2010 Installation

41 Installing on LinuxCreating a New Installation

5. Configuring SimManager within SimXpert

In order to publish and run templates, publish and retrieve data, or have access to a web portal, MSC SimManager client settings have to be configured.

• The appropriate protocol (http or https) and the host name of the server on which MSC SimManager is running is entered.

• A SimManager server could be running multiple Web Portals. A unique port number along with the name of the portal needs to be entered.

Note: SimXpert 2010 requires graphic display even while running templates in batch mode through SimManager. On Linux, this can be accomplished by installing GLX on the server where SimXpert is executed, or by setting the DISPLAY environment variable to a an X-Server with GLX support. Only one GLX capable machine is needed if you are running SimXpert on multiple servers. If SimXpert is run on a machine without GLX support, or without the DISPLAY environment variable set to an appropriate machine, you will see an error message similar to:ERROR: This system has no OpenGL support. Exiting...

Page 46: SimX 2010 Installation

SimXpert Installation and Operations GuideCreating a New Installation

42

Enter the communication protocol that your SimManager installation uses and click Next.

Enter the name of the Host computer running your SimManager installation and click Next.

Page 47: SimX 2010 Installation

43 Installing on LinuxCreating a New Installation

Enter the port number that your SimManager web application is running on and click Next.

Page 48: SimX 2010 Installation

SimXpert Installation and Operations GuideCreating a New Installation

44

Page 49: SimX 2010 Installation

45 Installing on LinuxCreating a New Installation

Enter the name of your SimManager web application context and click Next.

6. Configuring Pro/ENGINEER

In order to have direct access to Pro/ENGINEER Wildfire geometry, this CAD application must be installed locally on the same machine that is running SimXpert and must be licensed through its vendor.

Page 50: SimX 2010 Installation

SimXpert Installation and Operations GuideCreating a New Installation

46

For Pro/ENGINEER Wildfire, you will need to configure its settings manually by providing the location of the installation directory:

7. Installing CADNexus

If a 'Complete' installation was chosen or the 'SimXpert Native CAD Access Component' was selected for a 'User Selectable' installation, you will see the following dialog box at the end of the SimXpert installation process:

You will be asked to provide the location of the CADNexus installation media and click OK.

Please note that CADNexus installation is not an optional step on Linux systems.

Page 51: SimX 2010 Installation

47 Installing on LinuxCreating a New Installation

This finishes the installation of SimXpert.

Configuring SolversTo configure which version of Nastran is used by SimXpert you will need to modify entries in the simxpert.config and SimXpertNastran.config files. These files are located in install_dir/SimXpert_version#/operating_system/bin, for example: /MSC.Software/SimXpert/2010/LX86/bin

Statements need to be modified as follows:

simxpert.config

#

if [ -z "$MSCP_LOCAL_NASTRAN_CMD2004" ] ; then

export MSCP_LOCAL_NASTRAN_CMD2004=path/bin/mdnastran

fi

if [ -z "$MSCP_NASTRAN_CMD2004" ] ; then

export MSCP_NASTRAN_CMD2004=path/bin/mdnastran

fi

SimXpertNastran.config

NASTEXE path/bin

NASTEXE_2005 path/bin

Where path is the Nastran installation folder, for example: /MSC.Software/MD_Nastran/2010

Patran Database ImportSimXpert has the ability to import a Patran database. This requires an installation of Patran with the same version as the database that will be imported. The environment variable “MSC_SX_PATRAN_HOME” should be set to the path to the home directory. An example path is: C:\MSC.Software\MD_Patran\2010.

The Analysis preference of the Patran database must be set to MD or MSC.Nastran, and the model must have finite elements with properties assigned.

Page 52: SimX 2010 Installation

SimXpert Installation and Operations GuideCreating a New Installation

48