CC20 Series Tychem® Hood TM Head Protection Respiratory Protection Fire and Rescue Safety Thermal Imaging www.bullard.com Simple, Effective, Ultra-Light The CC20 Series Tychem® Hood provides a wide variety of simple, effective and economical options for on-the-job respiratory protection. The result is better protection,improved productivity and greater comfort that combines to produce the best value on the market. These hoods are available for use in a CC20 Series Airline Respirator configuration or PA20 Series Powered Air Purifying Respirator configuration. Approved by NIOSH for use in Type C applications, the CC20 Series is used in a wide variety of industries including: • pharmaceutical manufacturing • chemical and pesticide handling • spray painting and coating operations • nuclear operations Proven Performance In a 1996 study of hood-style respirators coordinated by the Organization Resources Counselors (ORC), the Bullard CC20 hood was surveyed to be the number one hood used in the pharmaceutical industry. The most commonly used hoods were then used in a simulated workplace protection factor study (SWPF). The Bullard CC20 hood was also the top-performing loose-fitting hood among a variety of competitors. All measurements in the SWPF study were above 150,000 resulting in a study Assigned Protection Factor (APF) of 10,000! For a summary of this research, call Bullard customer service at 1-800-827-0423.

Simple, Effective, Ultra-Light - Spray Pump Services

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

CC20 Series Tychem® HoodTM

HeadProtection

RespiratoryProtection

Fire and RescueSafety

ThermalImaging

www.bullard.com

Simple, Effective, Ultra-LightThe CC20 Series Tychem® Hood provides a wide variety of simple, effective and economicaloptions for on-the-job respiratory protection. The result is better protection, improvedproductivity and greater comfort that combines to produce the best value on the market. Thesehoods are available for use in a CC20 Series Airline Respirator configuration or PA20 SeriesPowered Air Purifying Respirator configuration. Approved by NIOSH for use in Type Capplications, the CC20 Series is used in a wide variety of industries including:

• pharmaceutical manufacturing

• chemical and pesticide handling

• spray painting and coating operations

• nuclear operations

Proven PerformanceIn a 1996 study of hood-style respirators coordinated by theOrganization Resources Counselors (ORC), the Bullard CC20 hoodwas surveyed to be the number one hood used in thepharmaceutical industry.

The most commonly used hoods were then used in a simulatedworkplace protection factor study (SWPF). The Bullard CC20hood was also the top-performing loose-fitting hood among avariety of competitors. All measurements in the SWPF studywere above 150,000 resulting in a study AssignedProtection Factor (APF) of 10,000!

For a summary of this research, call Bullard customerservice at 1-800-827-0423.

TM

Features and BenefitsUnique Air Delivery SystemA patented neck cuff design helps maintain positive pressure inside the hood to aid in keepingcontaminants out. As air enters the hood, the inner collar inflates, providing a snug,comfortable fit around the neck and continuous flow of air to the worker’s breathing zone.

Lightweight, Comfortable and EconomicalThe CC20 hood is lighter and more comfortable than tight-fitting full facepiece respirators.Covering the entire head, face and neck, the CC20 hood provides splash/overspray protectionand makes clean-up quick and easy.

A wide angle lens offers the largest field of vision among Tychem hood-style respirators on themarket, optimizing worker productivity and safety.

Available in a variety of styles, the CC20 hood is constructed of either Tychem QC or Tychem SLdepending on the job application. Taped and sealed seams are also available to providedadditional protection for liquid penetration encountered on-the-job or during decontamination.

Reusable or DisposableCC20 respirator hoods are durable enough to reuse, yet economical enough to discard after eachuse, depending on the work application.

No Fit TestingThe CC20 hood does notrequire fit testing norextensive recordkeeping. Iteasily accommodates beards,prescription eyewear orsafety glasses.

Powered Air orSupplied AirThe CC20 hood is a availablefor use as a supplied airrespirator (CC20 series) orpowered air respirator (PA20series). A versatile hoodsuitable for almost anyapplication.

CC20 Series Tychem® Hood

Hood style respirator does not requirefit testing and also allows for facial hairand eyewear.

Replaceable snap-in suspension providesultimate comfort, and maintains thefield of vision during activities.

Optional taped and sealed seams foradded protection.

Patented inflatable neck cuff designprovides superior, comfortableprotection, while delivering airflowdirectly into the worker’s breathingzone.

Wide angle lens offers the bestvisibility in the industry.

Bullard CC20 and PA20 RespiratorsWARNING

This hood is only one component of a CC20 or PA20 respirator system. By itself, thehood does not constitute a complete respirator. Read all instructions and warningsbefore using this respirator hood. Improper respirator use could result in death orserious injury, or may cause certain delayed lung diseases such as silicosis, pneumo-coniosis or asbestosis. These diseases may cause death. If you have questions onhow to use this respirator, ask your employer.Do not wear this respirator in any atmosphere immediately dangerous to life or health(IDLH), or from which you cannot escape without the aid of the respirator. Do not wearthe PA20 respirator in any atmosphere containing less than 19.5% oxygen. If you arenot sure whether the atmosphere is IDLH or oxygen deficient, ask your employer.

Prior to each use of this respirator system, BE CERTAIN of the following:FOR CC20 AIRLINE RESPIRATORSAIR SUPPLY: Grade “D” Breathable Air, as described in the Compressed GasAssociation Commodity Specifications G7.1, must be continuously supplied to the point-of-attachment. The point-of-attachment is the point at which the air supply hose connectsto the air source. A pressure gauge attached to the air source is used to monitor thepressure of air provided to the respirator wearer.AIR SOURCE: Be sure to locate the source of compressed breathing air in a clean airenvironment. Locate the air source far enough from your work site to ensure the airremains contaminant free.AIR PRESSURE at the point-of-attachment must be continuously maintained within thepressure ranges certified on the NIOSH Approval Label that appears in the User Manualsupplied with the original factory packaged system and on the table on the reverse sideof this label.NIOSH-APPROVED BULLARD AIR HOSE(S) must be used between the breathingtube connection fitting on the wearer’s belt and the point-of-attachment to the air supplysystem.APPROVED FITTINGS must be used to connect hose lengths together. Total connectedhose lengths and number of sections must be within the ranges specified on the NIOSHApproval Label and on the table on the reverse side of this label.BELT AIR CONNECTION FITTINGS must be attached to your belt or the separate beltsupplied with the system to help keep the air supply hose from snagging, disconnectingor pulling the hood off your head.PROTECTIONHEAD – Only the respirator models 20TICH and 20SICH provides head protection whenused with a Bullard hard hat.EARS – CC20 and PA20 respirators DO NOT provide hearing protection. Use properlyfitted earmuffs, earplugs or other protection when exposed to high noise levels.EYES – CC20 and PA20 respirators DO NOT provide eye protection. Wear approvedsafety glasses or goggles at all times.TYCHEM® – There are uses, environments and chemicals for which this garment is notsuitable. It is the responsibility of the user and the employer to determine that this gar-ment is appropriate for the intended use. This material should not be used around heat,open flames, sparks or in any potentially flammable or explosive environment. This mate-rial will burn and will melt. DuPont Tychem spunbonded olefin apparel fabrics have“Class 1 - Normal Flammability” characteristics, as tested according to the FlammableFabrics Act. “Class 1” fabrics will burn and do not provide thermal protection if a fire orexplosion should occur

“Pony tail” tag on everyhood provides informationon replacement parts, userguidelines, and requiredpressures.

Optional inner bibprovides addedprotection and somecooling of the torso

Climate control optionsallow the user to heat orcool the incoming air by asmuch as 30º F for comfortand productivity.

CC20 Series AirlineRespirator SelectionTM

Select one of each of the following four components:

1 Respirator Hood

CC20 Series

respirator hoods

are made of tough,

durable Tychem-

based materials

and feature a

wide-angle lens

for excellent

peripheral vision.

Choose the hood

style that is best

suited for the

work application.

Choose a head-

band or hard hat

to keep the hood

secure and stable.

The hard hat meets

ANSI Z89.1-1986

Class A and B

requirements for

impact,

penetration and

dielectric

protection. All

models come with

Sportek browpad.

Choose the breath-

ing tube assembly

appropriate for the

work application

and breathing air

source. Assemblies

available with con-

stant or adjust-

able airflow and a

variety of quick-

disconnect fittings.

Climate control

devices are avail-

able to cool or

warm incoming

air.

The breathing air

supply hose

connects the

breathing tube

assembly to the

air source. Choose

the air supply

hose suitable for

the air source.

Available in

different lengths.

Adjustable Flow

V40

Seri

es

Breathing TubeAssemblyIncludes breathingtube, 1/4" quickdisconnect fitting,flow control valve andbelt.

V30

Seri

es

Constant Flow

Breathing TubeAssemblyIncludes breathingtube, 1/4" quick-disconnect fitting and belt.

Adjustable Flow Climate Control Devices Constant Flow

AC10

00 S

erie

s

HC24

00 S

erie

s

Hot/Cold TubeAssemblyIncludes 1/4" quick-disconnect fittingand belt.*

DC50

40 S

erie

s

Dual-Cool™ AssemblyIncludes 1/4" quick-disconnect fitting andbelt. For use with acooling vest.*

Adjustable Flow

Frig

itro

n®20

00Se

ries

Cool Tube Assembly*Includes 1/2" quick-disconnect fitting andbelt.

Cool Tube AssemblyIncludes 1/4" quick-disconnect fittingand belt.*

V35

Seri

es

Breathing TubeAssemblyIncludes breathingtube, 1/2" quick-disconnect fitting and belt.

Material ChoicesTychem® QC - Tychem coatedwith polyethylene providesexcellent splash protectionagainst many acids, basesand other liquid chemicals.

Tychem® SL - (Used on SICNhood only) Tychem coatedwith SaranexTM 23-P providesprotection against an evenwider range of chemicals.

20TJN1, 20TPN3

Inne

r Bib

Sty

le

20TICN1, 20TPCN3 20SICN1, 20TICSN1

Inne

r Bib

Sty

le

20SICH2 , 20TICH2

Basi

c St

yle

Long

Out

er B

ib S

tyle

W

ith T

aper

ed S

eam

s

Sure

-Loc

k Ra

tche

tHe

adba

nd

20RT Sure-Lock® rat-chet headbandwith rear adjust-ment knob

Mod

el 3

000

Hard

Hat

3000 Cap-style hardhat. Includesstandard head-band (ESULTRA)

Stan

dard

Hea

dban

d

20TG Standard head-band with rearslide adjustment

Mod

el 3

000R

Har

d Ha

t

3000R Cap-style hardhat. IncludesSure-Lock® rat-chet headband(ESRTSL)

V10

Seri

es

Starter Hose Kitsin 25' (7.6 m) length.

For use with Breathing Air Compressors For use with Ambient Air Pumps

V20

Seri

es

Starter/Extension Hose Kitsin 50' (15.2 m) and 100' (30.5 m) lengths.

Maximum total length = 300 ft.

V5 S

erie

s

Starter/Extension Hose Kitsin 25' (7.6 m) and 50' (15.2m) lengths.

Maximum total length = 50 ft.

Air Source

Breathing Air Compressor

Air Source

Bullard Free-Air®

Pump

2 Headband or Hard Hat

3 Breathing Tube Assembly with Optional Climate Control

4 Breathing Air Supply Hose*Can only be used with Bullard EDP30 or ADP20 pump.

For use with Breathing Air Compressors For use with Ambient Air Pumps

Mod

el 5

100

Hard

Hat

5100 Cap-style hardhat. Includesstandard head-band (TG600)

Mod

el 5

100R

Har

d Ha

t

5100R Cap-style hardhat. Includesstandard head-band (TGRT600)

V10

Seri

es

V10 Extension Hose Kitsin 25' (7.6 m), 50' (15.2 m)and 100' (30.5 m) lengths.

Maximum total length = 300 ft.

1Headband style with .020" lens, 2Hard hat style with .040" lens3Headband style with solvent resistant .010 mylar lens

PA20 Replacement Parts

Choose a PA1 or

PA2 blower

assembly. All

blower assemblies

include a breathing

tube with clamp,

filter and gasket,

comfort belt, and

airflow indicator.

3

4 Battery Chargers

PA20

Ser

ies

PA1SMC Quick Chargerwith trickle chargecapability.

PA20

Ser

ies

PA1STC StandardCharger

PA20

Ser

ies

PA2SMC Quick Chargerwith trickle chargecapability.

PA20

Ser

ies

PA2STC StandardCharger

PA20

Ser

ies

PA1FG33-pack of HEPA filterswith gaskets

PA20

Ser

ies

PA1DBAll vinyl belt fordecontamination

PA20

Ser

ies

PA1DEBExtension belt fordecon belt

PA20

Ser

ies

PA1FGBP36-pack of HEPAfilters with gaskets

PA20

Ser

ies

PA1EBExtension belt forstandard belt

Blower Assembly

PA20

Ser

ies

PA1 Blower Assemblywith 10-hour batteryand low voltage alarm.

PA20

Ser

ies

PA2 Blower Assemblywith 6-hour battery.

Select one of each of the following four components:

1 Respirator Hood

CC20 Series

respirator hoods

are made of tough,

durable Tychem-

based materials

and feature a

wide-angle lens

for excellent

peripheral vision.

Choose the hood

style that is best

suited for the

work application.

Choose a head-

band or hard hat

to keep the hood

secure and stable.

The hard hat meets

ANSI Z89.1-1986

Class A and B

requirements for

impact,

penetration and

dielectric

protection. All

models come with

Sportek browpad.

Material ChoicesTychem® QC - Tychem coatedwith polyethylene providesexcellent splash protectionagainst many acids, basesand other liquid chemicals.

Tychem® SL - (Used on SICNhood only) Tychem coatedwith SaranexTM 23-P providesprotection against an evenwider range of chemicals.

20TJN1, 20TPN3

Inne

r Bib

Sty

le

20TICN1, 20TPCN3 20SICN1, 20TICSN1

Inne

r Bib

Sty

le

20SICH2 , 20TICH2

Basi

c St

yle

Long

Out

er B

ib S

tyle

W

ith T

aper

ed S

eam

s

Sure

-Loc

k Ra

tche

tHe

adba

nd

20RT Sure-Lock® rat-chet headbandwith rear adjust-ment knob

Mod

el 3

000

Hard

Hat

3000 Cap-style hardhat. Includesstandard head-band (ESULTRA)

Stan

dard

Hea

dban

d

20TG Standard head-band with rearslide adjustment

Mod

el 3

000R

Har

d Ha

t

3000R Cap-style hardhat. IncludesSure-Lock® rat-chet headband(ESRTSL)

2 Headband or Hard Hat

Mod

el 5

100

Hard

Hat

5100 Cap-style hardhat. Includesstandard head-band (TG600)

Mod

el 5

100R

Har

d Ha

t

5100R Cap-style hardhat. Includesstandard head-band (TGRT600)

1Headband style with .020" lens, 2Hard hat style with .040" lens3Headband style with solvent resistant .010 mylar lens

PA20 Series Powered AirPurifying Respirator SystemTM

©2002 Bullard. All rights reserved.Bullard, Free-Air, and Sure-Lock are registered trademarks of Bullard.It’s your life and you’re worth it is a trademark of Bullard.Tychem is a registered trademark of the DuPont Company

4062 (0702)

ISO 9001 certified

C ertifi

ed

ISO

9001

Bullard1898 Safety WayCynthiana, KY 41031-9303Toll free: +877-BULLARD (285-5273)Tel: +859-234-6616Fax: +859-234-8987www.bullard.com

Bullard GmbHHochkreuzallee 3653175 Bonn-Bad GodesbergGermanyTel: +49 228 931933 0Fax: +49 228 931933 50

TM

Respirator Hoods

Basic Style Hoods20TJN Tychem QC, no suspension

20TPN Tychem QC, no suspension, solvent resistant lens

Hood with inner bib, for use with headband20TICN Tychem QC, no suspension

20TPCN Tychem QC, no suspension, solvent resistant lens

Hood with inner bib, for use with hard hat20TICH Tychem QC, hard hat not included

20SICH Tychem SL, hard hat not included

Hood with inner bib and long outer bib, for use withheadband20TICSN Tychem QC, taped and sealed seams, no suspension

20SICN Tychem SL, taped and sealed seams, no suspension

Accessory Item for All Hoods20LCL Mylar lens covers (25/pkg)

Headbands and Hard Hats20TG Standard headband20RT Sure-Lock® ratchet headband3000 Hard hat with standard suspension, white3000R Hard hat with ratchet suspension, white

Accessories for Headbands and Hard HatsES-ULTRA Standard replacement suspension for 3000 hard hat

ESRTSL Replacement ratchet suspension for 3000R hard hat

20NC Chin strap for 20TG and 20RT headbands

ES42 Chin strap for 3000 and 5100 hard hats

Powered Air Purifying Respirator Components

Blower AssemblyPA1 Complete Blower Assembly with 10 hour battery

and Low Voltage Alarm PA2 Complete Blower Assembly with 6 hour battery

Battery ChargersPA1SMC Quick Charger for PA1PA1STC Standard Charger for PA1PA2SMC Quick Charger for PA2PA2STC Standard Charger for PA2

Replacement Parts and AccessoriesPA1AF1 Air Flow IndicatorPA1FG3 Filter/Gasket Assembly (pack of 3)PA1FGBP Filter/Gasket Assembly (pack of 36)PA1BT Breathing Tube for Heads (26" standard length)PA1BTXS Breathing Tube for Heads (22" length)PA1DB Decon Belt/Comfort PadPA1DEB Decon Extension Belt

Suplied Air Respirator Components

Breathing Tube20BT Breathing tube only (for supplied air)

Breathing Tube Assemblies (for supplied air)Include breathing tube, airflow control device, quick-disconnect nipple and belt. (Note: 20BT + F30 = V30)

Constant Flow Breathing Tube Assembly for use withBreathing Air Compressors (Schrader and Snap-Tite alsoavailable)V30 With 1/4" Industrial Interchange steel (Hansen

compatible) quick-disconnect nipple

Constant Flow Breathing Tube Assemblies for use withBullard Free-Air PumpsV35 With 1/2" Industrial Interchange, steel (Hansen

compatible) quick-disconnect nipple

Adjustable Flow Breathing Tube Assembly for use withBreathing Air Compressors (Schrader and Snap-Tite alsoavailable)V40 With 1/4" Industrial Interchange, steel (Hansen

compatible) quick-disconnect nipple

Replacement Parts for Breathing Tube AssemblyS18051 Nylon breathing tube clamp

4612 Belt, Nylon webbing

Flow Control DeviceFlow Control ValvesF30 Constant flow control valve with 1/4" Industrial

Interchange (Hansen compatible) quick-disconnectnipple (other industrial fittings available)

F40 Adjustable flow control valve with 1/4" IndustrialInterchange (Hansen compatible) quick-disconnectnipple (other industrial fittings available)

F35 Constant flow control valve with 1/2" IndustrialInterchange (Hansen compatible) quick-disconnectnipple

Climate Control Assemblies

For use with Breathing Air CompressorsCold Tubes – Adjustable Flow (Schrader and Snap-Tite alsoavailable)AC1000 With 1/4" Industrial Interchange steel (Hansen

compatible) quick-disconnect nipple

Hot/Cold Tubes - Adjustable Flow (Schrader and Snap-Titealso available)HC2400 With 1/4" Industrial Interchange steel (Hansen

compatible) quick-disconnect nipple

DUAL-COOL™ - Climate Control DeviceDC5040 With 1/4" Industrial Interchange steel (Hansen

compatible) quick-disconnect nipple. IncludesCH60 connector hose and nylon belt (Order vestseparately).

DC70M/L Medium/Large cooling vest

DC70XL/XXL X-Large/XX-Large cooling vest

Replacement Parts for Climate Control AssembliesMV2400 Muffler/valve assembly for HC2400

CH60 Connector hose for use with DC5040

Climate Control Assembly for use with Bullard EDP30 orADP20 Free-Air PumpCool Tube - Adjustable FlowFrigitron® With 1/2" Industrial Interchange steel 2000 (Hansen compatible) quick-disconnect nipple.

Air Supply Hoses and FittingsV10 Series Starter Hose Kits for use with Breathing AirCompressors (Schrader and Snap-Tite also available)Include 25' (7.6 m), 3/8" I.D. rubber hose with 1/4" femalequick-disconnect coupler and V13 adapter fitting (3/8" hose-to-3/8" pipe)

4696 With 1/4" Industrial Interchange steel (Hansencompatible) quick-disconnect coupler

V10 Series Extension Hose Kits for use with Breathing AirCompressorsInclude 3/8" I.D. rubber hose, V11 hose-to-hose adapter fittingand V13 hose-to-pipe fitting (3/8" hose-to-3/8" pipe)

5454 25' (7.6 m) Extension hose kit

5457 50' (15.2 m) Extension hose kit

5458 100' (30.5 m) Extension hose kit

V5 Series Coiled Hoses for use with Breathing AirCompressors (Schrader and Snap-Tite also available)Include 3/8" I.D. Nylon coiled hose with 1/4" female quick-disconnect coupler and 1/4" male quick-disconnect nipple

V52530 25' (7.6 m) with 1/4" Industrial Interchange steel(Hansen compatible) fittings

V55030 50' (15.2 m) with 1/4" Industrial Interchange steel(Hansen compatible) fittings

V20 Series Hoses for use with Bullard Free-Air PumpsInclude 1/2" I.D. rubber hose with 1/2" Industrial Interchange(Hansen compatible) female quick-disconnect coupler and 1/2"male quick-disconnect nipple

V2050ST 50' (15.2 m)V20100ST 100' (30.5 m)

CATALOGNUMBER DESCRIPTION

Ordering InformationCATALOGNUMBER DESCRIPTION

CATALOGNUMBER DESCRIPTION

CC20 respirators are not approved for use in any atmosphere immediately dangerous to lifeor health (IDLH) or from which the wearer cannot escape without the use of a respirator.Bullard products are manufactured and tested to exacting specifications. Any alteration ormodification of these products by the user may adversely affect product performance andvoids all product certifications. This data sheet is in summary form only for easy reference.Refer to labels and instructions accompanying the product for more complete detailsregarding use, maintenance, warnings and limitations.Failure to use complete NIOSH-approved Bullard components and replacement parts voidsapproval of entire assembly.

WARNING Distributed by