12
SIMOREG 6RA70 DC-MASTER Top performance and intelligence

SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

  • Upload
    vulien

  • View
    228

  • Download
    3

Embed Size (px)

Citation preview

Page 1: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

SIMOREG 6RA70 DC-MASTERTop performance and intelligence

Page 2: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

SIMOREG 6RA70 DC-MASTERA new lease on life for proven DC technology

• There are applications where DC

drives are simply the better solutionreason enough for us to innovate DCdrives. In many applications DC driveshave clear cut advantages in operatorfriendliness and reliability, costeffectiveness and performance,efficiency and start-up. When theseapplications are matched with theSIMOREG 6RA70 which are built onover 25 years of proven SIMOREGsuccess the results are unparalleled.

• Use the SIMOREG 6RA70 DC-

Master on your next application andlearn why the Siemens SIMOREGdrives continue to be the benchmarkin the DC drive industry.

Now with:

Unified operation with Siemens AC MASTERDRIVES

More application flexibility

More communication options

Extended output range to 1000hp(High hp designs up to 8000hp)

Even more compact sizing

Higher processing performance

More favorably priced solutions

Innovative features

TM

Page 3: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

With offices in 193 countries globalcoverage is available in even the

most remote locations.

The SIMOREG modular design has now been extended

from 15 Amps to 1660 Amps.

Modular and compatiblethrough and through

• Identical software platform

• Identical operator Interfaces

• Identical control card

• Identical option cards

• Identical card rack

• Identical manual

The SIMOREG 6RA70 is

extremely flexible and cost-effective in any application. In addition to the ability to expandthe standard functionality byadding option boards, the standardversion can be expanded to handle

higher-level software applicationswith the built in extendedtechnology software. In manyapplications the use of theextended technology software canreplace a technology board or eventhe PLC functions.

UUNNIIVVEERRSSAALL

CCOOVVEERRAAGGEE

MMOODDUULLAARR

PPHHIILLOOSSOOPPHHYY::

The SIMOREG 6RA70

DC-Master is known theworld over for its outstandingquality, reliability, and most of allperformance. With features suchas feed forward control on all ofthe inner control loops and a 83nsinstruction time made possible by itspowerful co-processor system theSIMOREG 6RA70 DC-Master standsunchallenged on its performance from everyend of the globe.

Page 4: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

MICRO-MASTER

MASTER-DRIVES VC

PC/PG SIMATIC HMI SIMATIC S7Generic PLCwith ProfibusCapabilities

PROFIBUS-DP

SIMOLINKMICROMASTER

MASTER-DRIVES MC

Standard AC drives DC drives Vector control AC drives Motion control servodrives

SIMOREG6RA70

Unified integration with the SIMOVERT MASTERDRIVES family

The SIMOREG 6RA70 DC-MASTERwas designed as a truly integratedmember of the Siemens MASTERDRIVESfamily. The 6RA70 having an identical cardrack and BICO software technology as the6SE70 AC drive series lends itself to usingthe same option cards including ProfibusCBP2 card, Simolink SLB card, T400Technology card, etc..

In addition to using the same option cardsas the 6SE70 AC MASTERDRIVE series,additional devices such as the OP1SOperator Control Panel are alsointerchangeable. This concept can greatlyreduce your inventory in addition to addingversatility and operator friendliness to yourdrive systems.

TM

Page 5: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

PROFIBUS DPThe most successful fieldbus standard worldwide.

12M baud max (copperwire) RS485Up to 127 nodes

CANController Area Network

16 word telegram availableUp to 124 nodes

1M baud

DEVICENETIndustrial Fieldbus

500K baudUp to 64 nodes

SIMOLINKFiber Optic ringbus.

Up to 201 nodes11M baud max.

PEER TO PEER5 word telegram

2 wire or 4 wire operation187.5K baud max.

USSCommunication protocol for OPIS,

SIMOVIS and QuickStart RS232 or RS485 (up to 31 nodes)

187.5K baud max.

TM

Unified communications throughout theSiemens applied drive family

In recent years the majority of drivecontrols have migrated from traditionalhard wiring to serial communications. TheSiemens 6RA70 DC MASTER series was

designed with this migration in mind and iscapable of being fully integrated into anyautomation environment.

THE PATH TO THE FUTURE:

Optimum Integration with Communications

Page 6: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

Unmatched:

Versatility & Performance

❖ Ability to auto-tune to variousmotors and applications

❖ Easily expandable with extended I/O, software functions, technology functions, etc.

❖ Can be fully integrated into any automation environment

❖ Extremely quick and simple start-up

❖ Absolutely no jumpers or potentiometers

❖ Modular through and through

❖ Extremely simple operator control using a unified controlphilosophy

❖ Up to four sets of parameterscan be stored in the drive andactivated at any time

SIM

OR

EG 6

RA

70

Page 7: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

Powerful drives for every

industrial sectorD

C-M

AS

TER

Page 8: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

Let our operator interfaces show you

everything you need to know

PMU SIMPLE OPERATOR PANEL

All units feature a PMU panel mounted inthe converter door. The PMU consists of afive-digit, seven-segment display, threeLEDs as status indicators and threeparameterization keys. The PMU providesall the facilities required during start-up formaking adjustments or settings anddisplaying measured values.

The PMU also features a 9 pin Sub-Dconnector with a USS interface incompliance with the RS232 or RS485standard.

PMU Built-in OperatorPanel

Everything at a glance, always under

control: OP1S operator control panel.

It can not be faster or simpler: Theoptional user-friendly OP1S operatorpanel with 4-line plain text display with16 characters provides even moreadvantages when it comes to user-friendliness and functionality. It allowsphysical quantities to be displayed, andcan be used as a handheld terminal orfor data saving; as the current values canbe quickly and electronicallyparameterized. Five different languagesare available for universal text display.The OP1S operator panel can be usedwith all SIMOREG 6RA70 DC-MASTERand SIMOVERT® MASTERDRIVES.Parameter sets can be easily upread anddownloaded, both offline and onlineusing the OP1S.

Page 9: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

QUICK START

For menu prompted start-up of anySIMOREG 6RA70 via the PC, try our freeQuick Start software. Quick Start willguide you with step by step instructionsand parameterize the SIMOREG 6RA70to your specific needs.

SIMOVIS

For a comprehensive PC tool with startup, drive control, parameter editing,monitoring, storage, printing anddiagnostic capabilities Siemens offersfree of charge SIMOVIS. SIMOVISsoftware is a multi-level tool forcommunication between your PC andSiemens drive.

DRIVES ES

The Drive Engineering System (DriveES), is the engineering tool used toconfigure, start up, and execute servicingand diagnostic operations of Siemensdrives from the SIMATIC platform.Integrating drive technology into theSIMATIC environment is made simple bythree components that make up DriveES.

Drive ES BasicDrive ES SIMATICDrive ES Graphic

Page 10: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

15 amp power module

15 amp base drive

Base drive and power module designs

For customer convenience and addedversatility the SIMOREG 6RA70 DC-MASTER is available in the base drive andpower module designs. Base drive designsinclude the power module mounted on abackplane with all the necessarycomponents and wiring for convenientinstallation.

High Hp SIMOREG

The SIMOREG 6RA70 is available in highHp designs up to 8,000Hp. These designsretain all the functionality and commonalityof the standard SIMOREG 6RA70.

Parallel Capabilities

One of the many features of theSIMOREG 6RA70 DC-MASTER is theability to parallel up to five identical powermodules for increased power capabilitiesand redundancy. Through the use of theCUD2 terminal expansion card aparalleling interface is readily available tosend the summated firing pulses to allconnected units.

The right drive for every requirement

Page 11: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

Ratings and Dimensions

SIMOREG 6RA70 DC Master

POWER MODULES

Regenerative and Non-Regenerative Models

Rated ArmatureAmps *

Typical Horse Power

at 240VDC at 500VDC Height Width Depth

15ADC30ADC60ADC100ADC140ADC210ADC255ADC430ADC510ADC850ADC1180ADC1660ADC

3Hp7.5Hp15Hp25Hp40Hp60Hp75Hp125Hp150Hp250Hp

7.5Hp15Hp30Hp60Hp75Hp125Hp150Hp250Hp300Hp500Hp700Hp1000Hp

15.2”15.2”15.2”15.2”15.2”15.2”24.6”24.6”27.6”30.7”34.6”34.6”

10.4”10.4”10.4”10.4”10.4”10.4”10.6”10.6”10.6”16.1”17.7”17.7”

9.4”12.3”12.3”12.3”12.3”12.3”12.5”12.5”14.2”14.3”19.7”19.7”

* Amp ratings are based on the US rating allowing an overload of 150% for 60 seconds.

SIMOREG 6RA70 DC Master

BASE DRIVES

Regenerative and Non-Regenerative Models

Rated ArmatureAmps *

Typical Horse Powerat 240VDC at 500VDC Height Width Depth

15ADC30ADC60ADC100ADC140ADC210ADC255ADC430ADC510ADC850ADC1180ADC1660ADC

3Hp7.5Hp15Hp25Hp40Hp60Hp75Hp125Hp150Hp250Hp

7.5Hp15Hp30Hp60Hp75Hp125Hp150Hp250Hp300Hp500Hp700Hp1000Hp

25.1”25.1”28.9”32.7”38.6”44.1”46.5”47.2”47.2”60”78”78”

10.6”10.6”10.6”10.6”11.4”11.4”11.4”21.6”21.6”32”32”32”

10.4”13.4”13.4”13.4”12.8”12.8”13.3”15.1”15.1”16.7”25”25”

* Amp ratings are based on the US rating allowing an overload of 150% for 60 seconds.

Specifications Input Voltage 460VAC, 3 Phase(other voltages available)

Frequency 45 to 65Hz, Automatic AdaptationArmature Voltage 240VDC max./230VAC Input

500VDC max./460VAC InputField Voltage 150VDC max./230VAC Input

300VDC max./460VAC InputControl and Fan Voltage Self contained in base drivesOperational Ambient 45 CInstallation Altitude Up to 3300 feet or 1000 metersSpeed Regulation .+/- 0.1% of rated speed with pulse

encoder and digital reference

Page 12: SIMOREG 6RA70 DC-MASTER - legacypower.netlegacypower.net/images/PDF/SCRDCDrivePDFPowerPoint/Siemens6RA70DC...MICROMASTER MASTER-DRIVES MC ... up, drive control, parameter editing,

TotallyIntegrated

Automation

Siemens Energy & Automation, Inc.Strategic Machinery Division5300 Triangle ParkwayNorcross, GA. 30092

Siemens Energy & Automation, Inc.Siemens is a registered trademark of Siemens AG.Specifications are subject to change without notice.

c

For Nearest Sales OfficeTEL: 1.800.964.4114

WEB: www.sea.siemens.com

SIMOREG is a Trademark of Siemens AGAll other trademarks are of Siemens AG.

Order No. DRBR-020843M1001SSS Printed in USA