Page 2: SimDE™MODEL Introduction

What’s New in Release 201512 §  S2i (s2ibis3) file import function §  C_comp re-order feature §  Warning for large mismatch on IV-VT checking (> 15%)

•  Selections: Stop or Continue §  IBIS file generation feature enhancement §  Update for handling the latest hspice update

§  Previous in V4.4 201504 •  Series/Series_switch IBIS model extraction and validation

support •  Using relative path for include files and libs when they are placed

inside Project folder •  Using scientific natation for IBIS buffer curve data •  Updated to ibischk6

© 2006-2015 IO Methodology Inc.

Page 3: SimDE™MODEL Introduction

SimDE™MODEL

§  The first complete IBIS model development and validation tool •  Support all IBIS buffer type extraction / generation •  Automated differential IBIS model (True, Pseudo and Half)

extraction / generation •  Integrated IBIS model validation for single-end and differential-

pair IBIS buffers •  Support IBIS 5.0 PDN feature extractions

§  The industry first Spice Macromodel development tool with Fitting and Validating functionalities •  Support advance digital buffer model development •  Automated Fitting and Validating functionalities with golden

waveforms •  Support analog model development

© 2006-2015 IO Methodology Inc.

Page 4: SimDE™MODEL Introduction

S2I Import

© 2006-2015 IO Methodology Inc.

Page 5: SimDE™MODEL Introduction

C_comp re-order function

© 2006-2015 IO Methodology Inc.

Page 6: SimDE™MODEL Introduction

Warning for large mismatch on IV-VT checking (> 15%)

© 2006-2015 IO Methodology Inc.

Page 7: SimDE™MODEL Introduction

Series/Series_switch extraction support

© 2006-2015 IO Methodology Inc.

Page 8: SimDE™MODEL Introduction

Using relative path for Libs and Include files

© 2006-2015 IO Methodology Inc.

Page 9: SimDE™MODEL Introduction

Using scientific notation for IBIS buffer data

© 2006-2015 IO Methodology Inc.

Page 10: SimDE™MODEL Introduction

Using IBISCHK6 for ibis file check

© 2006-2015 IO Methodology Inc.

Page 11: SimDE™MODEL Introduction

Automated batch mode operation for IBIS buffer generations of options/programmable settings

© 2006-2015 IO Methodology Inc.

Page 12: SimDE™MODEL Introduction

Auto-Set function for differential pair buffer VT fixture settings

© 2006-2015 IO Methodology Inc.

New Auto-Set feature can automatically set the differential pair VT fixture for IBIS modeling.

Page 13: SimDE™MODEL Introduction

IBIS VT/IT initial delay trim and curve length control

Proper Initial delay trim and curve length control will help for overclocking issue in IBIS simulations

© 2006-2015 IO Methodology Inc.

Page 14: SimDE™MODEL Introduction

Stimulus Rising / Falling edge control for IBIS VT extraction

This feature enables the total control for VT extraction stimulus configurations. It will allow to generate more accurate models for new advanced buffers

© 2006-2015 IO Methodology Inc.

Page 15: SimDE™MODEL Introduction

IBIS VT/IT Maximum Point Number Control

The most of times, VT/IT curves will only need few hundred points for keeping the accuracy of the models. This maximum number control will allow to minimize the file size significantly.

© 2006-2015 IO Methodology Inc.

Page 16: SimDE™MODEL Introduction

Current-Mode True-differential pair Support

Out of ordinary IBIS extraction methods with enhanced Weighted Best Point Reduction algorithm for accurate current-mode true-differential IBIS buffer model extractions

© 2006-2015 IO Methodology Inc.

Page 17: SimDE™MODEL Introduction

Selectable Extraction Simulation ONLY options for time consuming long simulations

Using script for simulation queue. Simulate first, extraction process using existing data later

© 2006-2015 IO Methodology Inc.

Page 18: SimDE™MODEL Introduction

Enhanced batch-mode operation for large number buffer generations in one project

© 2006-2015 IO Methodology Inc.

Page 19: SimDE™MODEL Introduction

Flexibility for IBIS version 3.2/4.2/5.0 buffer model generation to fit your customer needs

Choose the IBIS version your customer needs. SimDE™ will automatically generate version compatible IBIS buffers.

© 2006-2015 IO Methodology Inc.

Page 20: SimDE™MODEL Introduction

Supports SubModel (Dynamic Clamping) IBIS model type extractions

© 2006-2015 IO Methodology Inc.

Page 21: SimDE™MODEL Introduction

IBIS 5.0 PDN features with build-in test circuit

© 2006-2015 IO Methodology Inc.

Page 22: SimDE™MODEL Introduction

IBIS VALIDATOR

I-V I-T

V-T

TEXT

© 2006-2015 IO Methodology Inc.

Page 23: SimDE™MODEL Introduction

WAVFORM 3D View

© 2006-2015 IO Methodology Inc.

Page 24: SimDE™MODEL Introduction

Flexible stimulus controls for IBIS model generations

§  Delays •  Static •  Pulse

§  Levels •  High/Low •  Typ/Min/Max

© 2006-2015 IO Methodology Inc.

Page 25: SimDE™MODEL Introduction

Stimulus level control for different corner IBIS validations

© 2006-2015 IO Methodology Inc.

Page 26: SimDE™MODEL Introduction

Advanced “weighted” Best-Point algorithm for I-V curve representations

Curve with OLD algorithm

Curve with NEW algorithm

© 2006-2015 IO Methodology Inc.

Page 27: SimDE™MODEL Introduction

Both Transient and DC analysis modes available for I-V curve extractions

Insured to get the best result for I-V curve extractions

Spectre DC Analysis mode is not available in V2.2

© 2006-2015 IO Methodology Inc.

Page 28: SimDE™MODEL Introduction

Integrated MSIM simulator support for extraction and validation

© 2006-2015 IO Methodology Inc.

Page 29: SimDE™MODEL Introduction

Model Selector Builder

•  Build [Model Selector] from different IBIS files •  Load, Edit, Remove functionalities •  Can be added as a pin in IBIS file generation wizard

© 2006-2015 IO Methodology Inc.

Page 30: SimDE™MODEL Introduction

Manual Common-mode voltage setting option for differential pair IBIS extractions

§  Manual common-mode voltage setting option

§  Auto-detection still available

§  Increase IBIS buffer model accuracy by setting precision common-mode voltages for each corners

© 2006-2015 IO Methodology Inc.

Page 31: SimDE™MODEL Introduction

Multiple Simulator integrations

§  Supports •  Synopsys HSpice •  Cadence Spectre •  Mentor Eldo •  Texas Instrument Spice3 •  Legend MSIM

§  Seamless switching capability

© 2006-2015 IO Methodology Inc.

Page 32: SimDE™MODEL Introduction

IBIS Buffer Generation

Graphical Settings

Conditional Parameters

Configurable Blackbox

© 2006-2015 IO Methodology Inc.

Page 33: SimDE™MODEL Introduction

IBIS Generation Setting Wizards

Node Mapping

Node Mapping

C_comp Extraction

© 2006-2015 IO Methodology Inc.

Page 34: SimDE™MODEL Introduction

Extraction with existing data

§  Save simulation time §  Capable for other simulator

and / or measurement output §  With syntax checker

© 2006-2015 IO Methodology Inc.

Page 35: SimDE™MODEL Introduction

Easy IBIS curve inspection

© 2006-2015 IO Methodology Inc.

Page 36: SimDE™MODEL Introduction

Build-in Test circuit and Flexible Topology Editor for Validations

Differential report

© 2006-2015 IO Methodology Inc.

Page 37: SimDE™MODEL Introduction

Seamless Validation

© 2006-2015 IO Methodology Inc.

Page 38: SimDE™MODEL Introduction

Comprehensive IBIS File Builder

© 2006-2015 IO Methodology Inc.

Page 39: SimDE™MODEL Introduction

Macromodel Builder

© 2006-2015 IO Methodology Inc.

Page 40: SimDE™MODEL Introduction

Fitting for Accuracy

© 2006-2015 IO Methodology Inc.

Page 41: SimDE™MODEL Introduction

Fitting Result (DPI:1.14%, DAI:1.49%)

© 2006-2015 IO Methodology Inc.

Page 42: SimDE™MODEL Introduction

Free-Form Topology Editor for Validation

© 2006-2015 IO Methodology Inc.

Page 43: SimDE™MODEL Introduction

Validation Result

© 2006-2015 IO Methodology Inc.

Page 44: SimDE™MODEL Introduction

What is new in the future releases §  Model LOCK function §  Batch mode Model selection §  AMI and External Model wrapping §  Test Data §  Finally, AMI generation and validation

© 2006-2015 IO Methodology Inc.

Page 45: SimDE™MODEL Introduction

TMTM

http://www.iometh.com