5.2-1
Silencer
AN m00/AN m02/AN m03/25/AN
StandardSeries AN m00Over 30dB(A) noise reductionLow back pressureCompact and easy mounting
JIS symbol
Specifications
1.0MPa30dB(A) or more
5 to 60°C∗
FluidMax.operating pressureNoise reductionAmbient and fluid temperature
Compressed air
∗ It can operate in temperatures between –10 to 60°C if there is no risk of the moisture in the air freezing.
Model
(mm2) (g)
AN200-02 35 17 63 22 1925 84 25 2235 92 30 27
165 107 46 36225 132 50 41490 200 74 55580 233 74 60820 263 86 70
A B D1 4
AN300-03 603 8
AN400-04 901 2
AN500-06 1603 4
AN600-10 270111
AN700-12 4401 4
AN800-14 5901 2
AN900-20 9602
R(PT)WeightEffective areaPort sizeModel
Dimensions (mm)
Note) NPT thread is also available. Specify “N” after “ANm00-”. (Ex.: AN200-N02)
JIS symbol
Specifications
Model
Construction/Parts/DimensionsAN202
AN302/402
1.0MPa35dB(A) or more
5 to 60°C∗
FluidMax.operating pressureNoise reductionAmbient and fluid temperature
Compressed air
∗ It can operate in temperatures between –10 to 60°C if there is no risk of the moisture in the air freezing.
AN202-02 35 16 64 22 1933 84 28 2447 95 34 24
A B D1 4
AN302-03 603 8
AN402-04 901 2
Model Port sizeR(PT)
Effective area(mm2)
Weight(g)
Dimensions (mm)
Note) NPT thread is also available. Specify “N” after “ANm02-”. (Ex.: AN200-N02)
High noise reduction styleSeries AN m02 Over 35dB(A) noise reductionCase is UL94-V0 Grade Flame resistance material
AN500 to 900
Construction/Parts/DimensionsAN200 to 400
AN Series 2/18/99 7:36 PM Page 1
∗∗
2504-002 33.9 111 62 30 24106 64 30 24113 68 30 24
A B D1 4
2505-003 45.93 8
2506-004 50.01 2
310 88.5 48 352507-006 105.63 4
514 97.5 60 412508-010 129.6157 54 22 192510-002 17.21 4
55 56 22 192511-003 17.23 8
R(PT) (mm2) (g)Model Port size Effective area Weight Dimensions (mm)
Note) NPT thread is also available. Specify “N” after “25mm-“. (Ex.: 2504-N002)
Metal case styleSeries 25 Exhaust in only one direction.Prevents scattering of mist and noise.
JIS symbol
Specifications
Model
AN303/403
JIS symbol
Specifications
Model
Construction/Parts/Dimensions
ANm00/ANm02/ANm03/25/AN
1.0MPa25dB(A) or more
5 to 60°C∗
Operating fluidMax. operating pressure
Noise reductionAmbient and fluid temperature
Compressed air
∗ It can operate in temperatures between –10 to 60°C if there is no risk of the moisture in the air freezing.
R(PT) (mm2) (g)
AN103-01 10 1 23.5 11 —3 36 16 1417 66 22 19
A B D1 8
AN203-02 151 4
AN303-03 353 8
25 84 25 22AN403-04 601 2
Model Port size Effective area Weight Dimensions (mm)
Note) NPT thread is also available. Specify “N” after “ANm03-“. (Ex.: AN103-N01)
1.0MPa19dB(A) or more
5 to 60°C∗
Compressed airOperating fluidMax. operating pressure
Noise reductionAmbient and fluid temperature
∗ It can operate in temperatures between –10 to 60°C if there is no risk of the moisture in the air freezing.
AN200 to 900·················SAN, #1 to #8AN202 to 402·················SAN, #9 to #11AN103 to 403·················SAN, #12 to #15
Compact styleSeries ANm03Over 25dB(A) noise reductionSpace savingCompact style
Construction/Parts/DimensionsAN103 AN203
5.2-2
AN
VEX
AMC
AN Series 2/18/99 7:36 PM Page 2
∗∗∗
5.2-3
AN101-01
AN110-01
AN120-M3
AN120-M5
16 21
1.0MPa
5 to 50°C∗
13 18
20 35 1 5
9.5 20 1 3.322.5 38 9 1711
AB 13 6 8
R(PT) R(PT)M3 M51 8 1 8
SpecificationsModel
Port size
FluidNoise reduction dB(A)
Max. operating pressAmbient and fluid temperature
Effective area(mm2)Weight (g)Dimensions(mm)
Note) NPT thread for AN101 and AN110 is alsoavailable. Model no. of NPT thread is AN101-N01 and AN110-N01.
∗ It can operate in temperatures between –10° to 150°C if there is no risk of the moisture in the air freezing.
Compressed air
(BC Sintered Body)Series AN Ideal for the exhaust of a compact valve or pilot air.
Jis symbol
Specifications/Model
Construction/Parts/Dimensions
AN m00/AN m02/AN m03/25/AN
Flow Characteristics (Initial conditions) Noise Level (Initial conditions)
AN200 to 900
AN202 to 402
AN103 to 403
2504 to 2511
AN200 to 900Condition: 0.5MPa at supply pressure of solenoid valveMeasurement distance: AN200 to 500→1M AN600 to 700→2m
AN800 to 900→3m
AN202 to 402Condition: 0.5MPa at supply pressure of solenoid
valveMeasurement distance: 1m
AN103 to 403Condition: 0.5MPa at supply pressure of solenoid
valveMeasurement distance: 1m
2504 to 2511Condition: 0.5MPa at supply pressure of solenoid
valveMeasurement distance: 1m
AN101-01······················SAN, #16AN110-01······················SAN, #17AN120-M3·····················SAN, #18AN120-M5·····················SAN, #19
AN Series 4/15/1999 4:41 PM Page 3
∗∗
5.2-4
Mounting
One-touch Fitting Connection StyleSeries ANmmm-KMmmCan connect with One-touchfitting directly
JIS symbol
Specifications
Model
Construction/Parts/Dimensions
AN203-KM8
ANm00/ANm02/ANm03/25/AN
AN103-KM6AN103-X233AN103-X235
Precautions
Warning
1.0MPa5 to 60°C
Compressed airFluidMax. operating pressure
Ambient and fluid temperature
ø6(Series KQ)
(mm2)
AN103-KM6ø6(Series KQ)AN103-X233
AN103-X235ø8(Series KQ)AN203-KM8ø8(Series KQ)AN200-KM8
ø10(Series KQ)AN200-KM10ø10(Series KQ)AN300-KM10ø12(Series KQ)AN300-KM12
7 37 11 15
14 51 16 26
A B C
20 78 22 5426
25
3081 22 54
30 97 25 7041 98 25 70
ø 41 " (Series KQ)
ModelApplicable One-touch
fitting size
Noise reduction
dB(A)
Effective area Dimensions (mm)
Be sure to read before handling. Refer top.0-33 to 0-36 for Safety Instructions and common precautions.
1 The exhaust port could become blocked by the clogging of thesilencer. Therefore, make sure to provide a safe design so as not tocause the system as a whole to malfunction.
1 The silencing effect could vary depending on the pneumatic circuitor the pressure that is used.
1 If the silencer body (case) is made of plastic and is BC sintered:To mount on a valve, hold the end of the body (the side that is notthreaded) with your fingers and screw it in. After some resistance isfelt, use a wrench that matches the wrench flats of the hexagonportion to tighten it an additional 1/4 turn. (If the silencer is not pro-vided with a hexagon portion, manually tighten it firmly.)
2 If the silencer body is made of metal (except the BC sintered style),tighten it at the torque given below.
12 to 14Rc(PT) 1 4
22 to 24Rc(PT) 3 8
28 to 30Rc(PT) 1 2
28 to 30Rc(PT) 3 4
36 to 38Rc(PT)140 to 42Rc(PT)1 1 4
1 2 48 to 50Rc(PT)148 to 50Rc(PT)2
Connection thread Applicable tightening torque (Nm)
3 Make sure not to apply a lateral load to the body during or after theinstallation.
Maintenance/Inspection
Caution1 Never disassemble the silencer. The silencing material is not
replaceable.2 If the exhaust speed drops and the system performance decreas-
es due to clogging, replace with a new silencer. Make sure to ver-ify the operating conditions of the actuator at least once a day.
ANm0m0-KMmm
AN
VEX
AMC
Design
Caution
Caution
AN Series 2/18/99 7:37 PM Page 4
∗∗
5.2-5
How to Order
Model (Screw-in connection)Model Port size
Effective area(mm2)
Weight(g)
ANA1-01 10 4 37 16
22 84 25 2136 98 30 24
110 111 46 36180 132 50 41544 200 74 60612 230 74 60873 271 86 70
A B CDimensions (mm)
1 8
ANA1-02 15 14 64 22 181 4
ANA1-03 353 8
ANA1-04 601 2
ANA1-06 903 4
ANA1-10 160111
ANA1-12 2801 4
ANA1-14 4501 2
ANA1-20 6102
—
Construction/Parts/DimensionsANA1-01 to 06
JIS symbol
A1 03AN
Symbol Noise reduction levelA1 40dB(A)
Series
01Symbol Port size Connection
Screw-in∗
One-touch
02 1 4
03 3 8
04 1 2
06 3 4
1 4
10 112 1
1 211420 2
C08 (ø8 One-touch fittings size)
C10 (ø10 One-touch fittings size)
C12 (ø12 One-touch fittings size)
1 8
Port size
∗ Only R (PT) is available.
Specifications
40dB(A)Noise reduction effect
Fluid1.0MPaMax. operating pressure
5 to 60°cAmbient and fluid temparature
Refer to p.5.2-4 for precautions on these products.
Compressed air
ANA1-01 to 20
Model (One-touch fitting connection)Model
One -touchfitting size
ø8ø10ø12
Effective area(mm2)
Weight(g)
ANA1-C08 11 5 58 16
19 95 25
A BDimensions (mm)
ANA1-C10 15 13 76 22ANA1-C12 33
Construction/DimensionsANA1-C08 to C12
∗ ANA1-06: PP
A high noice reduction style silencerkeeps the noise level inside a plantbelow 85dB(A).
40dB(A): High Noise Reduction Silencer
Series ANA1
AN Series 2/18/99 7:37 PM Page 5
∗∗
5.2-6
How to Order
38dB(A): High Noise Reductione Silencer
Series ANB1Model (Screw-in connection)
Model Port sizeEffective area
(mm2)Weight
(g)
ANB1-0122 81 25 1835 93 30 2194 107 46 24175 133 50 41462 190 74 41612 230 74 60871 271 86 70
A B CDimensions (mm)
1 8
ANB1-0215 10 51 22 —
1 4
ANB1-0335
3 8
ANB1-0460
1 2
ANB1-0690
3 4
ANB1-10160
111
ANB1-12280
1 4
ANB1-14450
1 2 610
Construction/Parts/DimensionsANB1-01 to 04
JIS symbol
B1 03AN
01Symbol Port size Connection
Screw-in∗
One-touch
02 1 4
03 3 8
04 1 2
06 3 4
1 4
10 112 1
1 2114C06C08C10
1 8
Port size
(ø6 One-touch fittings size)(ø8 One-touch fittings size)
(ø10 One-touch fittings size)
∗ Only R (PT) is available.
Symbol Noise reduction levelB1 38dB(A)
Series
Specifications
38dB(A)Noise reduction effect
Fluid1.0MPaMax. operating pressure
5 to 60°CAmbient and fluid temparature
Refer to p.5.2-4 for precautions on these products
Compressed air
ANB1-06 to 14
Model (One-touch fitting connection)
ø6ø8ø10
ANB1-C06 8 5 52 16
28 94 25
A B
ANB1-C08 13 12 73 22ANB1-C10 28
ModelOne -touchfitting size
Effective area(mm2)
Weight(g)
Dimensions (mm)
Construction/DimensionsANB1-C06 to C10
∗ ANB1-04: PP
Series ANB1 <noise reduc -tion effect: 38dB(A) > thathas a larger effective areawith the same port size asSeries ANA1. It is alsoavailable for commonexhaust from manifolds,etc.
AN
VEX
AMC
AN Series 2/18/99 7:37 PM Page 6
∗∗
2504-002 33.9 111 62 30 24106 64 30 24113 68 30 24
A B D1 4
2505-003 45.93 8
2506-004 50.01 2
310 88.5 48 352507-006 105.63 4
514 97.5 60 412508-010 129.6157 54 22 192510-002 17.21 4
55 56 22 192511-003 17.23 8
R(PT) (mm2) (g)Model Port size Effective area Weight Dimensions (mm)
Note) NPT thread is also available. Specify “N” after “25mm-“. (Ex.: 2504-N002)
Metal case styleSeries 25 Exhaust in only one direction.Prevents scattering of mist and noise.
JIS symbol
Specifications
Model
AN303/403
JIS symbol
Specifications
Model
Construction/Parts/Dimensions
ANm00/ANm02/ANm03/25/AN
1.0MPa25dB(A) or more
5 to 60°C∗
Operating fluidMax. operating pressure
Noise reductionAmbient and fluid temperature
Compressed air
∗ It can operate in temperatures between –10 to 60°C if there is no risk of the moisture in the air freezing.
R(PT) (mm2) (g)
AN103-01 10 1 23.5 11 —3 36 16 1417 66 22 19
A B D1 8
AN203-02 151 4
AN303-03 353 8
25 84 25 22AN403-04 601 2
Model Port size Effective area Weight Dimensions (mm)
Note) NPT thread is also available. Specify “N” after “ANm03-“. (Ex.: AN103-N01)
1.0MPa19dB(A) or more
5 to 60°C∗
Compressed airOperating fluidMax. operating pressure
Noise reductionAmbient and fluid temperature
∗ It can operate in temperatures between –10 to 60°C if there is no risk of the moisture in the air freezing.
AN200 to 900·················SAN, #1 to #8AN202 to 402·················SAN, #9 to #11AN103 to 403·················SAN, #12 to #15
Compact styleSeries ANm03Over 25dB(A) noise reductionSpace savingCompact style
Construction/Parts/DimensionsAN103 AN203
5.2-2