12
Asian Journal of Research in Social Sciences and Humanities Asian Journal of Research in Social Sciences and Humanities Vol. 6, No. 8, August 2016, pp. 2027-2051. ISSN 2249-7315 A Journal Indexed in Indian Citation Index DOI NUMBER: 10.5958/2249-7315.2016.00729.2 Category:Science and Technology 2027 Asian Research Consortium www.aijsh.com Literature Review Paper on Analysis and Control of Small Signal Stability with DFIG based Wind Power System M. Panneer Selvam*; P. Prakasam** *Department of Electrical and Electronics Engineering, Sona College of Technology, Salem, India. **Department of Electronics and Communication Engineering, United Institute of Technology, Coimbatore, India. Abstract As a result of the increasing demand for electric power and environmental problems, the generation of electrical energy from renewable sources has increased recently. In particular, the wind power plants are integrated in large numbers to power system networks to satisfy the demand. For wind turbine energy generation, doubly fed induction generators are highly implemented owing to more advantages over fixed speed wind turbine systems. These generators can enhance the stability and power quality of the power networks. More attention had been paid by researchers so far on various issues with respect to grid integration of DFIG system. This review paper provides in-depth analysis and discussion on various aspects of DFIG fed wind power systems and its grid integration till date and also suggestions for further growth in this area for effective wind power energy management systems. Keywords: Doubly-fed induction generator (DFIG), Power System Stabilizer (PSS), Maximum Power Point Tracking (MPPTs), Low Voltage/Fault Ride Through Capability (LVRT/FRT). References Global Wind Report Annual market update 2014, Global wind energy council. J.G.Slootweg. “Wind power, modeling and impact on power system dynamics”. PhD Thesis, Power Systems Laboratory, Delft University of Technology, 2003.

Signal Stability with DFIG based Wind Power System · PDF fileKeywords: Doubly-fed induction generator (DFIG), Power System Stabilizer (PSS), Maximum Power Point Tracking (MPPTs),

  • Upload
    donga

  • View
    220

  • Download
    0

Embed Size (px)

Citation preview

Asian Journal

of Research in

Social Sciences

and

Humanities Asian Journal of Research in Social Sciences and Humanities Vol. 6, No. 8, August 2016, pp. 2027-2051.

ISSN 2249-7315 A Journal Indexed in Indian Citation Index

DOI NUMBER: 10.5958/2249-7315.2016.00729.2Category:Science and Technology

2027

Asian Research Consortium

www.aijsh.com

Literature Review Paper on Analysis and Control of Small Signal Stability with DFIG based Wind Power System

M. Panneer Selvam*; P. Prakasam**

*Department of Electrical and Electronics Engineering,

Sona College of Technology,

Salem, India.

**Department of Electronics and Communication Engineering,

United Institute of Technology,

Coimbatore, India.

Abstract

As a result of the increasing demand for electric power and environmental problems, the generation of electrical energy from renewable sources has increased recently. In particular, the wind power plants are integrated in large numbers to power system networks to satisfy the demand. For wind turbine energy generation, doubly fed induction generators are highly implemented owing to more advantages over fixed speed wind turbine systems. These generators can enhance the stability and power quality of the power networks. More attention had been paid by researchers so far on various issues with respect to grid integration of DFIG system. This review paper provides in-depth analysis and discussion on various aspects of DFIG fed wind power systems and its grid integration till date and also suggestions for further growth in this area for effective wind power energy management systems.

Keywords: Doubly-fed induction generator (DFIG), Power System Stabilizer (PSS), Maximum Power Point Tracking (MPPTs), Low Voltage/Fault Ride Through Capability (LVRT/FRT).

References

Global Wind Report Annual market update 2014, Global wind energy council.

J.G.Slootweg. “Wind power, modeling and impact on power system dynamics”. PhD Thesis, Power Systems Laboratory, Delft University of Technology, 2003.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2028

H. Li, and Z. Chen, “Overview of different wind generator systems and their comparisons,” IET Renewable Power Generation, vol. 2, no. 2, pp. 123-138, 2008.

W. Leonhard, Control of electrical drives, Springer- Verlag, 1985.

S. R. Jones and R. Jones, “A control strategy for sinusoidal supply side convertors,” IEE Colloquium on Developments in Real-Time Control for Induction Motor Drives, Digest, pp. 5/1-5/9, Feb. 1993.

R. Pena, G. Asher, J. Clare and R. Cardenas, “A constant frequency constant voltage variable speed stand alone wound rotor induction generator,” International Conference on Opportunities and Advances in International Electric Power, pp. 111-114, Mar. 1996.

R. Pena, J. C. Clare and G. M. Asher, “Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind energy generation,” IEE Proceedings on Electrical Power Applications, Vol.143, No.3, pp. 231-241, May., 1996.

R. Pena, J. C. Clare and G. M. Asher, “A doubly fed induction generator using back-to-back PWM converters supplying an isolated load from a variable speed wind turbine,” IEE Proceedings on Electrical Power Applications, Vol.143, No.5, pp.380-387, Sep., 1996.

S. K. Salman and BabakBadrzadeh, “New Approach for modelling Doubly-Fed Induction Generator (DFIG) for grid-connection studies,” European Wind Energy Conference & Exhibition 2004, Nov., 2004.

R. Cardenas, R. Pena, J. Clare, G. Asher and J. Proboste, “MRAS Observer for Sensorless Control of Standalone Doubly Fed Induction Generators,” IEEE Transaction on Energy Conversion, Vol.20, No.4, pp.710-718, Dec., 2005.

R. Cardenas, R. Pena, J. Clare, G. Asher and J. Proboste, “MRAS Observer for Sensorless Control of Doubly Fed Induction Generators,” IEEE Transaction on Power Electronics, Vol.23, No.3, pp.1075-1084, May, 2008.

P. Wheeler, J. Rodriguez, J.C. Clare, L. Empringham, and A. Weinstein, “Matrix converters: a technology review,” IEEE Transaction on Industrial Electronics, Vol.49, No.2, pp.276-288, Apr., 2002.

R. Cardenas, R. Pena, G. Tobar, R. Blasco-Gimenez, P. Wheeler, G. Asher and J. Clare, “Analytical and experimental evaluation of a WECS based on a Doubly Fed Induction Generator fed by a matrix converter,” IEEE international Symposium on Industrial Electronics, pp.2438-2443, Jun., 2008.

R. Cardenas, R. Pena, P. Wheeler, J. Clare and G. Asher, “Control of the Reactive Power Supplied by a WECS Based on an Induction Generator Fed by a Matrix Converter,” IEEE Transaction on Industrial Electronics, Vol.56, No.2, pp.429-438, Feb., 2009.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2029

R. Cardenas, R. Pena, J. Clare and P. Wheeler, “Control of the Reactive Power Supplied by a Matrix Converter,” IEEE transaction on Energy conversion, Vol. 24, No.1, pp.301-303, Mar., 2009.

R. Cardenas, R. Pena, G. Tobar, P. Wheeler and G. Asher, “Stability Analysis of a Wind Energy Conversion System Based on a Doubly Fed Induction Generator Fed by a Matrix Converter,” IEEE Transaction on Industrial Electronics, Vol.56, No.10, pp.4194-4206, Oct., 2009.

P. Kundur, “Power system stability and control,” New York: McGraw- Hill, 1994.

P. Kundur, J. Paserba, V. Ajjarapu et al., “Definition and classification of power system stability,” IEEE Trans. Power Syst., vol. 19, no. 3, pp. 1387-1401, 2004.

Dynamics and Control of. Electric Power Systems. Lecture 227-0528-00, ITET ETH. GöranAndersson. EEH - Power Systems Laboratory. ETH Zürich, 2010

F. P. Demello, and Concordia.C, “Concepts of synchronous machine stability as affected by excitation control,” IEEE Trans. Power Appar. & Syst., vol. PAS-88, no. 4, pp. 316-329, 1969.

F. J. Swift, and H. F. Wang, “The connection between modal analysis and electric torque analysis in studying the oscillation stability of multimachine power systems,” International Journal of Electrical Power & Energy Systems, vol. 19, no. 5, pp. 321-330, 1997.

Chih-Ming Lin, Vittal V, Kliemann W, Fouad A A. “Investigation of modal interaction and its effects on contralperformace in stressed power systems using normal forms of vector fields”. IEEE Trans on PowerSyst., vol.11, no. 2, pp. 781~787, 1996.

J. F. Hauer, C. J. Demeure, and L. L. Scharf, “Initial results in prony analysis of power system response signals,” IEEE Trans on Power Syst., vol. 5, no. 1, pp. 80-89, Feb, 1990.

W.Du, H.F.Wang and R.Dunn, “Power system oscillation stability and control by facts and ESS-survey”, International Conference on Sustainable Power Generation and Supply, pp. 1-13, 2009.

H.F. Wang, F.J. Swift, M. Li, “A unified model for the analysis of FACTS devices in damping power system oscillations. II. Multimachine power systems”, IEEE Trans. Power Deliv. vol.13, no. 4, pp. 1355–1362, 1998.

T. Smed, and G. Andersson, “Utilizing HVDC to damp power oscillations,” IEEE Trans. Power Deliv., vol. 8, no. 2, pp. 620-627, 1993.

X. Yuxiao, Y. Rongxiang, Z. Zhiyiet al., “Review of PSS based on WAMS suppressing low frequency oscillation of interconnected power grid,” Proceedings of the 2009 International Conference on Energy and Environment Technology , pp. 255-258, 2009.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2030

J. G. Slootweg, and W. L. Kling, “The impact of large scale wind power generation on power system oscillations,” Electric Power SystemsResearch, vol. 67, no. 1, pp. 9-20, Oct, 2003.

D. J. Vowles, C. Samarasinghe, M. J. Gibbardet al., “Effect of Wind Generation on Small-Signal Stability - A New Zealand Example,” 2008IEEE Power & Energy Society General Meeting, pp. 5217-5224, 2008

D. Gautam, V. Vittal, and T. Harbour, “Impact of increased penetration of DFIG-based wind turbine generators on transient and small signal stability of power systems,” IEEE Trans. Power Syst., vol. 24, no. 3, pp. 1426-1434, Aug, 2009.

E. Hagstrom, I. Norheim, and K. Uhlen, “Large-scale wind power integration in Norway and impact on damping in the Nordic grid,” Wind Energy, vol. 8, no. 3, pp. 375-384, 2005.

O. Anaya-Lara, F. M. Hughes, N. Jenkins et al., “Influence of windfarms on power system dynamic and transient stability,” WindEngineering, vol. 30, no. 2, pp. 107-27, 2006.

F. M. Hughes, O. Anaya-Lara, N. Jenkins et al., “A power system stabilizer for DFIG-based wind generation,” IEEE Trans. Power Syst.,vol. 21, no. 2, pp. 763-772, May, 2006.

E. Muljadi, C. P. Butterfield, B. Parsons et al., “Effect of variable speed wind turbine generator on stability of a weak grid,” IEEE Trans. On Energy Conversion, vol. 22, no. 1, pp. 29-36, 2007.

G. Tsourakis, B. M. Nomikos, and C. D. Vournas, “Effect of wind parks with doubly fed asynchronous generators on small-signal stability,” Electric Power Systems Research, vol. 79, no. 1, pp. 190-200, Jan, 2009.

G. Tsourakis, B. M. Nomikos, and C. D. Vournas, “Contribution of Doubly Fed Wind Generators to Oscillation Damping,” IEEE Trans. onEnergy Conversion, vol. 24, no. 3, pp. 783-791, Sep, 2009.

N. R. Ullah, and T. Thiringer, “Effect of operational modes of a wind farm on the transient stability of nearby generators and on power oscillations: a Nordic grid study,” Wind Energy, vol. 11, no. 1, pp. 63-73,2008.

D. Gautam, V. Vittal, and T. Harbour, “Impact of increased penetration of DFIG-based wind turbine generators on transient and small signal stability of power systems,” IEEE Trans. Power Syst., vol. 24, no. 3, pp.1426-1434, Aug, 2009.

A. B. Morton, “Wind turbines and oscillatory stability in power systems: towards a general approach,” Proceedings of the 2009 AustralasianUniversities Power Engineering Conference (AUPEC 2009), pp. 6 pp.,2009.

G. Ramtharan, N. Jenkins, O. Anaya-Lara et al., “Influence of rotor structural dynamics representations on the electrical transient performance of FSIG and DFIG wind turbines,” Wind Energy, vol. 10, no. 4, pp. 293-301, Jul-Aug, 2007.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2031

Anca D. Hansen, Florin Iov, PoulSørensen, NicolaosCutuluis et al.“Dynamic wind turbine models in power system simulation tool DigSILENT”, Risø-R-1400(EN), 2007

Shi LB, Wang C, Yao LZ, Wang LM, Ni YX. Analysis of impact of grid-connected wind power on small signal stability. Wind Energy 2011;14:517–37.

Petersson A, Thiringer T, Harnefors L, Petru T. Modeling and experimental verification of grid interaction of a DFIG wind turbine. IEEE Trans Energy Convers 2005;20(4):878–86.

Feij´oo A, Cidr´as J, Carrillo C. A third order model for the doublyfed induction machine. Elect Power Syst Res 2000;56(2):121–7.

Salameh ZM, Kazda LF. Analysis of the double output induction generatorusing direct three-phase model Part II: harmonic analysis. IEEE Trans EnergyConvers 1987;12(2):182–8.

Ekanayake JB, Holdsworth L, Jenkins N. Comparison of 5th order and 3rd order machine models for doubly fed induction generator (DFIG) wind turbines. Elect Power Syst Res 2003;67(3):207–15.

Ledesma P, Usaola J. Effect of neglecting stator transients in doubly fed induction generator models. IEEE Trans Energy Convers 2004;19(2):459–61.

Nayeem RU, Thiringer T. Variable speed wind turbines for power systemstability enhancement. IEEE Trans Energy Convers 2007;22(1):52–60.

Istvan E, Jörg K, Jens F, Stephan ME, Holger W. Modeling of wind turbinesbased on doubly-fed induction generators for power system stability studies.IEEE Trans Power Syst 2007;22(3):909–19.

Mustafa K, Milanovic JV. Assessing transient response of DFIG-based windplants – the influence of model simplifications and parameters. IEEE Trans Power Syst 2008;23(2):545–54.

Feng Wu, Zhang XP, Ping J, Michael JH, Sterling MJH. Decentralized nonlinear control of wind turbine with doubly fed induction generator. IEEE Trans Power Syst 2008;23(2):613–21.

Tsourakis G, Nomikos BM, Vournas CD. Contribution of doubly fed windgenerators to oscillation damping. IEEE Trans Energy Convers 2009;24(3):783–91.

Slootweg J, Kling W. The impact of large scale wind power generation onpower system oscillations. Electric Power Syst Res 2003;67(1):9–20.

Meegahapola L, Flynn D, Kennedy J, Littler T. Impact of wind generation mixon transient stability for an interconnected power system. In: Proc European wind energy conference; 2009.

Anaya LO, Hughes F, Jenkins N, Strbac G. Influence of wind farms on power system dynamic and transient stability. Wind Eng 2006;30:107–27.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2032

Ayodele TR, Jimoh AA, Munda JL, Agee JT. The influence of wind power on the small signal stability of a power system. In: International conference on renewable energies and power quality; 2011.

Wang C, Shi L, Wang L, Ni Y. Small signal stability analysis considering gridconnected wind farms of DFIG type. IEEE Power Energy Soc Gen Meet 2008:1–6.

Muljadi E, Butterfield C, Parsons B, Ellis A. Effect of variable speed wind turbine generator on stability of a weak grid. IEEE Trans Energy Convers2007;22:29–36.

Tsourakis G, Nomikos B, Vournas C. Effect of wind parks with doubly fed asynchronous generators on small-signal stability. Electr Power Syst Res 2009;79:190–200.

Lingling F, Kavasseri R, Lee ZM, Chanxia Z. Modeling of DFIG based wind farms for SSR analysis. IEEE Trans Power Del 2010;25(4):2073–82.

Lingling F, Chanxia Z, Lee ZM, Minqiang H. Modal analysis of a DFIG-based wind farm interfaced with a series compensated network. IEEE Trans Energy Convers 2011;26(4):1010–20.

Zhu C, Hu M, Wu Z. Parameters impact on the performance of a double-fed induction generator-based wind turbine for subsynchronous resonance control. IET Renew Power Gen 2012;6(2):92–8.

Ostadi A, Yazdani A, Varma RK. Modeling and stability analysis of a DFIGbased wind-power generator interfaced with a series-compensated line. IEEE Trans Power Del 2009;24(3):1504–14.

Suriyaarachchi DHR, Annakkage UD, Karawita C, Jacobson DA. A procedure to study sub-synchronous interactions in wind integrated power systems. IEEE Trans Power Syst 2012.

Faried SO, Unal I, Rai D, Jean M. Utilizing DFIG based wind farms for damping subsynchronous resonance in nearby turbine-generators. IEEE Trans Power Syst 2012;99:1–8.

Wu F, Zhang Z, Godfrey K, Ju P. Small signal stability analysis and optimal control of a wind turbine with doubly fed induction generator. IET GenerTransmDistrib 2007;1:751–60.

Mishra Y, Mishra S, Tripathy M, Senroy N, Dong ZY. Improving stability of a DFIG-based wind power system with tuned damping controller. IEEE Trans Energy Convers 2009;24(3):650–60.

Yang L, Yang GY, Xu Z, Dong ZY, Wong KP, Ma X. Optimal controller design of a doubly-fed induction generator wind turbine system for small signal stability enhancement. IET GenerTransmDistrib 2010;4(5):579–97.

Gautam D, Vittal V, Terry H. Impact of increased penetration of DFIG-based wind turbine generators on transient and small signal stability of power systems. IEEE Trans Power Syst 2009;24(3):1426–34.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2033

Zhixin M, Fan L, Dale O, Yuvarajan S. Control of DFIG-based wind generation to improve interarea oscillation damping. IEEE Trans Energy Convers 2009;24(2):415–22.

Fan L, Yin H, Zhixin M. On active/reactive power modulation of DFIG-based wind generation for interarea oscillation damping. IEEE Trans Energy Convers 2011;26(2):513–21.

Tsili M, Papathanassiou S. A review of grid code technical requirements for wind farms. IET Renew Power Gen 2009;3(3):308–32.

Ekanayake JB, Holdsworth L, Wu X, Jenkins N. Dynamic modeling of doubly fed induction generator wind turbines. IEEE Trans Power Syst2003;18(2):803–9.

Sulla F, Svensson J, Samuelsson O. Short-circuit analysis of a doubly fed induction generator wind turbine with direct current chopper protection. Wind Energy 2011.

Rodriquez M, Abad G, Sarasola I, Gilabert A. Crowbar control algorithms for doubly fed induction generator duringvoltage dips. EurConf Power Electron Appl 2005.

Lopez J, Guba E, Sanchis P, Olea E, Ruiz J, Marroyo L. Ride through of wind turbines with doubly fed induction generator under symmetrical voltage dips. IEEE Trans Ind Electron 2009;56(10):4246–54.

Morren J, de Haan SWH. Short-circuit current of wind turbines with doubly fed induction generator. IEEE Trans Energy Convers 2007;22(1):174.

Poller MA. Doubly-fed induction machine models for stability assessment of wind farms. In: IEEE Int power tech conference; 2003.

Thiringer T, Petersson A, Petru T. Grid disturbance response of wind turbines equipped with induction generator and doubly-fed induction generator. In: Proc IEEE power engsoc gen meeting, vol. 3. 2003; p. 1542–7.

Morren J. Sjoerd, de Haan SWH. Ridethrough of wind turbines with doublyfed induction generator during a voltage dip. IEEE Trans Energy Convers 2005;20(2):545–54.

Kasem AH, El-Saadany EF, El-Tamaly HH, Wahab MAA. An improved fault ride-through strategy for doubly fed induction generator-based wind turbines. IET Renew Power Gen 2008;2(4):201–14.

Kasem AH, El-Saadany EF, El-Tamaly HH, Wahab MAA. A new fault ridethrough strategy for doubly fed wind-power induction generator. In: IEEE electrical power conference; 2007. p. 1–7.

Rahimi M, Parniani M. Efficient control scheme of wind turbines with doubly fed induction generators for low voltage ride-through capability enhancement. IET Renew Power Gen 2010;4(3):242–52.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2034

Flannery PS, Venkataramanan G. A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter. IEEE Trans Power Electron 2008;23(3):1126–34.

Vieira JPA, Nunes MVA, Bezerra UH, Nascimento AC. Designing optimal controllers for doubly fed induction generators using a genetic algorithm. IET GenerTransmDistrib 2009;3(5):472–84.

Mohseni M, Islam S, Masoum MAS. Fault ride-through capability enhancement of doubly-fed induction wind generators. IET Renew Power Gen 2011;5(5):368–76.

Chondrogiannis S, Barnes M. Specification of rotor side voltage source inverter of a doubly-fed induction generator for achieving ridethrough capability. IET Renew Power Gen 2008;2(3):139–50.

Hu J, He Y. DFIG wind generation systems operating with limited converter rating considered under unbalanced network conditions – analysis and control design. Renew Energy 2011;36(2):829–47.

Yao J, Li H, Liao Y, Chen Z. An improved control strategy of limiting the dc-link voltage fluctuation for a doubly fed induction wind generator. IEEE Trans Power Electron 2008;23(3):1205–13.

Xiang D, Ran L, Tavner P, Yang S. Control of a doubly fed induction generator in a wind turbine during grid fault ride through. IEEE Trans Energy Convers 2006;21(3):652–62.

Lima F, Luna A, Rodriguez P, Watanable E, Blaabjerg F. Rotor voltage dynamics in the doubly-fed induction generator during grid faults. IEEE Trans Power Electron 2009;25(1):118–30.

Feltes C, Wrede H, Koch F, Erlich I. Enhanced fault ridethrough method for wind farms connected to the grid through VSC-based HVDC transmission. IEEE Trans Power Syst 2009;24(3):1537–46.

Mohsen R, Parniani M. Transient performance improvement of wind turbines with doubly fed induction generators using nonlinear control strategy. IEEE Trans Energy Convers 2010;25(2):514–25.

Wei Q, Venayagamoorthy GK, Harley RG. Real-time implementation of aSTATCOM on a wind farm equipped with doubly fed induction generators. In: IEEE IAS 41st ann meet. Tampa; 2006. p. 1073–80.

Wei Q, Venayagamoorthy GK, Harley RG. Real-time implementation of a statcom on a wind farm equipped with doubly fed induction generators. IEEE Trans IndAppl 2009;45(1):98–107.

Meegahapola LG, Littler T, Flynn D. Decoupled-DFIG fault ride-through strategy for enhanced stability performance during grid faults. IEEE TransSustain Energy 2010;1(3):152–62.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2035

Wei Q, Harley RG, Venayagamoorthy GK. Coordinated reactive power control of a large wind farm and a STATCOM using heuristic dynamic programming.IEEE Trans Energy Convers 2009;24(2):493–503.

Vieira JPA, Nunes MVA, Bezerra UH, Nascimento AC. Designing optimal controllers for doubly fed induction generators using a genetic algorithm. IET GenerTransmDistrib 2009;3(5):472–84.

Francisco KAL, Luna A, Rodriguez P, Watanabe EH, Blaabjerg F. Rotor voltage dynamics in the doubly fed induction generator during grid faults. IEEE Trans Power Electron 2010;25(1):118–30.

Omar AB, Nasiri A. A dynamic LVRT solution for doubly fed induction generators. IEEE Trans Power Electron 2010;25(1):193–6.

Yang J, Fletcher JE, O’Reilly J. A series-dynamic-resistor-based converter protection scheme for doubly-fed induction generator during various fault conditions. IEEE Trans Energy Convers 2010;25(2):222–32.

Lin Y, Lin LZ. Study of superconducting fault current limiters for system integration of wind farms. IEEE Trans ApplSupercond 2010;20(3):1233–7.

Liye X, Shaotao D. Enhancing low-voltage ride-through capability and smoothing output power of DFIG with a superconducting fault-current limiter–magnetic energy storage system. IEEE Trans Energy Convers 2012;27(2):227–95.

Pannell G, Atkinson DJ, Zahawi B. Minimum-threshold crowbar for a faultride- through grid-code-compliant DFIG wind turbine. IEEE Trans EnergyConvers 2010;25(3):750–9.

Liang J, Qiao W, Harley RG. Feed-forward transient current control for lowvoltage ride-through enhancement of DFIG wind turbines. IEEE Trans Energy Convers 2010;25(3):836–43.

Pena R, Clare JC, Asher GM. A doubly fed induction generator using back-toback PWM converters supplying an isolated load from a variable speed wind turbine. IEE Proc Electric Power Appl 1996; 143 (5): 380–7.

Muller S, Deicke M, De Doncker RW. Doubly fed induction generator systems for wind turbines. IEEE IndAppl Mag 2002;8(3):26–33.

Manfred D. Direct self-control of the flux and rotary moment of a rotary-field machine. US patent 4678248; 7 July, 1987.

Liu O, Mohammed A, Liu S. A novel direct torque control of doubly-fed induction generator used for variable speed wind power generation. In: IEEE Power engineering society general meeting; 2007. p. 1–6.

Kazmierkowski MP, Kasprowicz A. Improved direct torque and flux vector control of PWM inverter-fed induction motor drives. IEEE Trans IndElectr 1995;42(4):344–50.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2036

Baader U, Depenbrock M, Gierse G. Direct self-control (DSC) of inverter-fed induction machine – a basis for speed control without speed measurement IEEE Trans IndAppl 1992;28(3):581–8.

Vas P. Sensorles vector and direct torque control. Oxford (UK): Clarendon; 1998.

Habetler TG, Profumo F, Pastorelli M, Tolbert LM. Direct torque control of induction machines using space vector modulation. IEEE Trans IndAppl 1992;28(5):1045–53.

Noguchi T, Tomiki H, Kondo S, Takahashi I. Direct power control of PWM converter without power-source voltage sensors. IEEE Trans IndAppl 1998;34(3):473–9.

Kang J, Sul S. New direct torque control of induction motor for minimum torque ripple and constant switching frequency. IEEE Trans IndAppl 1999;35(5):1076–82.

Lai YS, Chen JH. A new approach to direct torque control of induction motor drives for constant inverter switching frequency and torque ripple reduction. IEEE Trans Energy Convers 2001;16(3):220–7.

Malinowski M, Kazmierkowski MP, Hansen S, Blaabjerg F, Marques GD. Virtual-flux-based direct power control of three-phase PWM rectifiers. IEEE Trans IndAppl 2001;37(4):1019–27.

Gokhale KP, Karraker DW, Heikkila SJ. Controller for a wound rotor slip ring induction machine. US Patent 6 448 735 B1; 2002.

Escobar G, Stankovic AM, Carrasco JM, Galvan E, Ortega R. Analysis and design of direct power control (DPC) for a three phase synchronous rectifier via output regulation subspaces. IEEE Trans Power Electron 2003;18(3):823–30.

Idris NRN, Yatim AHM. Direct torque control of induction machines with constant switching frequency and reduced torque ripple. IEEE Trans Ind Electron 2004;51(4):758–67.

Xu L, Cartwright P. Direct active and reactive power control of DFIG for wind energy generation. IEEE Trans Energy Convers 2006;21(3):750–8.

Abad G, Miguel ÁR, Poza J. Three-level npc converter-based predictive direct power control of the doubly fed induction machine at low constant switching frequency. IEEE Trans Ind Electron 2008;55(12):4417–29.

David SM, Jose LRA, Santiago A. Dynamic programming power control for doubly fed induction generators. IEEE Trans Power Electron 2008;23(5): 23–37.

Tremblay E, Atayde S, Chandra A. Comparative study of control strategies for the doubly fed induction generator in wind energy conversion systems: a DSP-based implementation approach. IEEE Trans Sustain Energy 2011;2(3):288–97.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2037

Raza KSM, Goto H, Hai JG, Ichinokura O. Review and critical analysis of the research papers published till date on maximum power point tracking in wind energy conversion system. IEEE Energy Convers Congr Exposition 2010:4075–82.

Abdullah MA, Yatim AHM, Tan CW, Saidur R. A review of maximum power point tracking algorithms for wind energy systems. Renew Sustain Energy Rev 2012;16(5):3220–7.

Tan K, Islam S. Optimum control strategies in energy conversion of PMSG wind turbine system without mechanical sensors. IEEE Trans Energy Convers 2004;19(2):392–9.

Barakati SM, Kazerani M, Aplevich JD. Maximum power tracking control for a wind turbine system including a matrix converter. IEEE Trans Energy Convers 2009;24(1):705–13.

Koutroulis E, Kalaitzakis K. Design of a maximum power tracking system for wind-energy-conversion applications. IEEE Trans Ind Electron 2006;53(2):486–94.

Kazmi SMR, Hiroki GHJG, Osamu I. A novel algorithm for fast and efficient speed-sensorless maximum power point tracking in wind energy conversion systems. IEEE Trans Ind Electron 2011;58(1):29–36.

Ranjan V. Nonlinear, optimal control of a wind turbine generator. IEEE Trans Energy Convers 2011; 26(2): 468–78.

Azzouz M, Elshafei A, Emara H. Evaluation of fuzzy-based maximum powertracking in wind energy conversion systems. IET Renew Power Gener 2011;5(6):422–30.

Cardenas R, Pena R. Sensorless vector control of induction machines for variable-speed wind energy applications. IEEE Trans Energy Convers 2004;19(1):196–205. [19]

Datta R, Ranganathan VT. A method of tracking the peak power points for a variable speed wind energy conversion system. IEEE Trans Energy Convers 2003;18(1):163–8. [20]

Muhando EB, Senjyu T, Uchida K, Kinjo H, Funabashi T. Stochastic inequality constrained closed-loop model-based predictive control of MW-class wind generating system in the electric power supply. IET Renew Power Gener 2010;4(1):23–35.

Wei Q, Wei Z, José MA, Harley RG. Wind speed estimation based sensorless output maximization control for a wind turbine driving a DFIG. IEEE Trans Power Electron 2008;23(3): 1156–69.

Choon YT, Yi G, Jiang JN. Nonlinear dual-mode control of variable- speed wind turbines with doubly fed induction generators. IEEE Trans Control SystTechnol 2011;19(4):744–56.

Jabr HM, Dongyun L, Kar NC. Design and implementation of neuro-fuzzy vector control for wind-driven doubly-fed induction generator. IEEE Trans Sustain Energy 2011;2(4):404–13.

Jabr HM, Iyer LV, Sen C, Kar NC. Self-adjusting and fuzzy logic gain schedulers for vector control of wind driven doubly-fed induction generator. Int J Environ Stud 2012;69(2):299–313.

Selvam & Prakasam (2016). Asian Journal of Research in Social Sciences and Humanities,

Vol. 6, No.8, pp. 2027-2051.

2038

Ghedamsi K, Aouzellag D. Improvement of the performances for wind energy conversions systems. Int J Electr Power Energy Syst 2010;32(9):936–45.

Elkhatib K, Abdel A, Reza G, Mireille B. Robust nonlinear control of wind energy conversion systems. Int J Electr Power Energy Syst 2013;44(1):202–9.

Song HH, Qu YB. Energy-based excitation control of doubly-fed induction wind generator for optimum wind energy capture. Wind Energy 2012.

Chen BA, Lu TK, Hsu YY, Chen WL, Lee ZC. An analytical approach to maximum power tracking and loss minimization of a doubly fed induction generator considering core loss. IEEE Trans Energy Convers 2012;27(2):449–56.

Esmaeil R, Ahmadreza T, Mohammad E. Dynamic model and control of DFIG wind energy systems based on power transfer matrix. IEEE Trans Power Del 2012;27(3):1485–93.

Morimoto S, Nakayama H, Sanada M, Takeda Y. Sensorless output maximization control for variable-speed wind generation system using PMSG. IEEE Trans IndAppl 2005;41(1): 60–7. [21]

Maurizio C, Marcello P. Growing neural gas (GNG)-based maximum power point tracking for high-performance wind generator with an induction machine. IEEE Trans IndAppl 2011;47(2):861–72. [22]

Iuliana M, Bacha S, Iuliana AB, Jöel G, Daniel R. Energy-reliability optimization of wind energy conversion systems by sliding mode control. IEEE Trans Energy Convers 2008;23(3):985–97.

Shen B, Bakari M, Zhang Y, Ooi BT. Sensorless maximum power point tracking of wind by DFIG using rotor position phase lock loop (PLL). IEEE Trans PowerElectron 2009;24(4):42–51.

Lie Xu, DaweiZhi, Barry WW. Predictive current control of doubly fed induction generators. IEEE Trans Ind Electron 2009;56(10):4143–53.

Whei ML, Chih MH. A new elman neural network-based control algorithm for adjustable-pitch variable-speed wind-energy conversion systems. IEEE Trans Power Electron 2011;26(2):473–81.

Malik OP, Westwick DT. Multiple model predictive control for wind turbines with doubly fed induction generators. IEEE Trans Sustain Energy 2011;2(3):215–25.

Brice B, Mohamed EHB, Tarek AA. Second-order sliding mode control of a doubly fed induction generator driven wind turbine. IEEE Trans Energy Convers 2012;27(2):261–9.

Kim KH, Van TL, Lee DC, Song SH, Kim EH. Maximum output power tracking control in variable-speed wind turbine systems considering rotor inertial power. IEEE Trans Ind Electron 2012.