Modular SmartGrid ready USB plug 15-240 kW + redundancy 25-400 kW + redundancy 42-1008 kW + redundancy • Utmost availability • Ultimate scalability • Unmatched power density • Efficiency >96.5% • Multiple controls • Highly flexible • Advanced comms HIGHLIGHTS Multi Power UPS (MPW and MPX)is the ultimate modular UPSfor DATA CENTRES and other CRITICAL LOADs. Multi Power is designed to protect any critical high-density computer and IT environment, whilst achieving maximum availability. Multi Power grows along with the demands of your business without over-sizing the UPS- optimizing both the initial investment and the Total Cost of Ownership (TCO). As soon as demand increases, The Multi Power modular solution can expand its power capability, maintaining the highest levels of power protection, availability, redundancy and investment savings. Digital technology has an increasingly strong influence on day-to-day activities in almost all sectors and applications such as healthcare, power generation, social networking, telecommunications, commerce and education. Subsequently, any activities and equipment related to data storage, processing and transfer should be supplied from the most reliable power source. Multi Power ensures that a scalable, secure, high quality power supply is available for a variety of critical load applications. The new MPW and MPX Power Modules feature the very latest in UPS technology. With its three-level Neutral Point Clamped (NPC)inverter and Power Factor Corrected (PFC)input control, the Multi Power ensures the highest level of performance in terms of overall efficiency, input power factor and harmonic impact on the supply source. Hot swap battery Lithium compatible 3:3 Modular UPS System SIEL Energy Systems POWER PROTECTION SOLUTIONS For mission critical applications & essential services telephone: 0845 1306118 email:[email protected] www.sielenergy.co.uk SIEL DATMPW3P20CREN On-Line

SIEL DATMPWM3P20CREN Brochure

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SIEL DATMPWM3P20CREN Brochure

Modular

SmartGridready

USBplug

15-240 kW+ redundancy25-400 kW+ redundancy42-1008 kW+ redundancy

• Utmost availability

• Ultimate scalability

• Unmatched powerdensity

• Efficiency >96.5%

• Multiple controls

• Highly flexible

• Advanced comms

HIGHLIGHTSMulti Power UPS (MPW and MPX)is theultimate modular UPSfor DATA CENTRESand other CRITICALLOADs.Multi Power is designed to protect anycritical high-density computer and ITenvironment, whilst achievingmaximumavailability. Multi Power grows along withthe demands of your businesswithoutover-sizing the UPS- optimizing both theinitial investment and the Total Cost ofOwnership (TCO). As soon as demandincreases,The Multi Power modular solution canexpand its power capability, maintainingthe highest levels of power protection,availability, redundancy and investmentsavings.Digital technology has an increasinglystrong influence on day-to-day activitiesin almost all sectors and applications

such as healthcare, power generation,social networking, telecommunications,commerce and education.Subsequently, any activities andequipment related to data storage,processing and transfer should besupplied from the most reliable powersource. Multi Power ensures that ascalable, secure, high quality powersupply is available for a variety of criticalload applications. The new MPWand MPXPower Modules feature the very latestin UPS technology. With its three-levelNeutral Point Clamped (NPC)inverterand Power Factor Corrected (PFC)inputcontrol, the Multi Power ensures thehighest level of performance in terms ofoverall efficiency, input power factor andharmonic impact on the supply source.

Hot swapbattery

Lithiumcompatible

3:3

Modular UPS System

SIEL Energy SystemsPOWER PROTECTION SOLUTIONSFor mission critical applications & essential services

telephone: 0845 1306118

email:[email protected]

www.sielenergy.co.uk

SIELDATMPW3P20CREN

On-Line

Page 2: SIEL DATMPWM3P20CREN Brochure

ADVANCED TECHNOLOGYTo ensure the highest levels of poweravailability, only the most reliable, cuttingedge power components and innovativecontrol technologies have been used in thedevelopment of the MPWand MPXpowermodules and other major aspects of thesystem. The major power componentsand assemblies within the Multi Powerhas been specifically designed and tailormade in conjunction with the respectivecomponent manufacturers. This designwork ensures that the Multi Powerachieves the highest levels of powerand performance. In order to optimisethe overall performance of the finishedproduct, the UPS’R&Dteam made thedecision to specifically design certainpower components, including the IGBTmodules and associated packages. Ratherthan using standard components that arereadily available in the marketplace,Multi Power hosts one single optimisedand reliable power assembly whichguarantees the best availability and overallefficiency.The Power Module itself utilises a“wireless power principle” meaning thatthe power interconnection distancesbetween the cards, power componentsand connectors are shorter. In this waywe reduce any risk related to connectionproblems between the assemblies andalso minimise the overall power losses.

SCALABILITYMulti Power provides a comprehensive,easy to integrate power protectionsolution for data centres and any criticalIT application matching the evolvingdemands of a networked environment.The end user can easily increase power,redundancy level and battery autonomyby simply adding additional UPS PowerModules (PM) and Battery Units (BU).Three different cabinets are available tobuild the system: the Power Cabinets(MPW and MPX type) and the BatteryCabinet (BTC). The Power Cabinets canaccommodate either 15kW (MPX15PM),25kW (MPX25 PM) or 42 kW Power Modules(MPW 42 PM).The available UPSpower and redundancylevel can expand vertically from:• 15to 75 kW in one single Power Cabinet(MPX 130 PWCwith MPX 15PM)

• 25 to 125kW in one single Power Cabinet(MPX130 PWCwith MPX25 PM)

• 42 to 294 kW in one single Power Cabinet(MPW300 PWCwith MPW 42 PM).

Up to four complete Power Cabinets canbe connected in parallel, increasing thecapacity including redundancy respectivelyfrom:• 75 up to 300 kW (with MPX15PM)• 125up to 500 kW (with MPX25 PM)• 294 up to 1176kW (with MPW 42 PM)The Battery Cabinet accommodatesmultiples of 4 Battery Units, with up

to 36 units within a single frame witha maximum of 10Battery Cabinetsconnected in parallel.In addition, Multi Power is available asan optimised solution providing a MULTIPOWER/Battery combination with theCombo Cabinet (MPW and MPX type).This solution can be utilised withinextremely compact areas requiring a smallfootprint with maximum power density.This modular and reliable solution isperfect for any small to medium businessapplications.The user might decide to build the solutionusing the combination of three MPW42 PMand five battery shelves (MPW 130CBC)orfour MPX15PM / MPX25 PM and six batteryshelves (MPX100 CBC) not mingling thetwo power rates in the same cabinet.

OUTSTANDINGPERFORMANCES• The advanced technologies deployedwithin the Multi Power guarantees fullrated power even with unity powerfactor loads (kVA=kW)without any powerdowngrading even when operating attemperatures up to 40°C.

• High system efficiency whilst operatingin ON LINEdouble-conversion modegreater than 96.5%. Even when loaded atonly 20%, the Multi Power still achievesan outstanding performance greaterthan 95%.This superior performance

Power Cabinet MPW 300 PWC (1-7 x MPW 42 PM) x 4

Power Module 42 kW - MPW 42 PM

Battery Unit Array - 4 x BU

Power Module 15kW - MPX15PMPower Module 25 kW - MPX25 PM

Page 3: SIEL DATMPWM3P20CREN Brochure

ensures extremely low losses at anyload level whilst maintaining a truemodular solution for any changing UPSenvironment in terms power demands.

• Low input harmonic pollution, withnear unity input power factor and anextremely wide input voltage operatingrange (+20/-40%), requiring only aminimum upstream power source ratingand subsequent reduced investmentcosts.

MULTIPLE CONTROLSThe entire Multi Power solution wasdeveloped with particular care toensure operational reliability andprevent any possible failures dueto miscommunication between thecomponent parts of the system.The Power Modules are not controlled byone unique microprocessor, but by three -each having different and specific duties.Likewise, the Power Cabinet featurestwo separate microprocessors; one toregulate the overall UPSoperations and aseparate one to manage communicationwith the user. In addition, three dedicatedcommunications bus manage and transmitthe data. In terms of the monitoringand control of the overall system, allmajor components are continuallytemperature monitored within each of thePower Modules. In addition, up to four-temperature sensors are embedded withinthe Power Cabinet to ensure constant andefficient operation.The Power Module is equipped with threespeed controlled fans to ensure there isno energy wasted as the load level appliedto the system increases or decreases.At the same time each fan features aso-called third wire (the controller) whichimmediately warns the microprocessorin the event of a fault; in which case themicroprocessor will increase the speedof the remaining operational fans in orderto compensate for the cooling deficiency.The Battery Unit also contains dedicatedinternal protection and a sophisticatedcontrol system to monitor the status ofeach module. This makes it possible tocheck the voltage/current supplied byeach single battery module and thereforeidentify and warn the user if one of themis defective or beginning to fail. Thissignificantly reduces the risk of a batterypack failure causing a problem to thesystem by immediately warning the userof the impending issue in order for theappropriate preventive actions to be takenbefore it is too late.

FLEXIBLEMODULARITYMulti Power grows both verticallyand horizontally from 1to 20 PowerModules (MPX15PM/MPX 25 PM) or 1to28 Power Modules (MPW42 PM)up to1176kW (including redundancy) as wellas battery units (from 1cabinet, up to10),therefore the system is completelyscalable in accordance with any businessrequirements. The Plug& Play modularconcept simplifies any power or batteryautonomy expansion process, rather thana complete Power Module or Battery unitreplacement.The modular hot-swappable principle isfurther extended to all major elementsof the system, resulting in convenientreplacement of parts such as fans fromwithin individual Power Modules ratherthan accessingmajor components withinthe cabinet. Furthermore, all PowerModules and critical components are

easily accessible from the front of theunit as standard. The system is equippedwith a Manual Bypass change over switchand Back-feed control with a mechanicalinterlock contactor inbuilt, eliminating anymaintenance-related downtime (inbuiltcontactor is optional for MPX130PWCand MPX100 CBC).Combination systems(Combo Cabinet) and Battery Cabinetare supplied with a battery switch andshunt trip to enable remote batteryswitch operation. All these featuresensure easy UPSexpansion, operationand maintenance; minimising downtime,decreasing the Mean Time to Repair (MTTR)and removing any possible risk to powercontinuity, when carried out by authorisedservice personnel. Flexibility is measuredby the ease of both on site installation andthe operations undertaken by the user.Input/Output/battery terminal bars aredeployed enabling authorised installers to

Combo Cabinet MPX100 CBC(1-4 MPX 15PM or MPX 25 PM)

+ 1-6 Battery shelves.

Combo Cabinet MPW 130CBC(1-3 x MPW 42 PM) + 1-5 Battery Shelves

with front door air filter(optional available on all cabinet types).

Page 4: SIEL DATMPWM3P20CREN Brochure

easily terminate the cables either from thetop or the bottom of the system (for MPX130PWC bottom entry only).Mechanical supports and cable glandsas well as the terminal bar positioning (inthe centre of the cabinet) are purposelypositioned to reduce the installationtime and costs. In addition, in termsof flexibility of the battery installation,whether a conventional or modular typesystem is implemented these can bearranged in two different configurations:centralised (common battery) ordistributed (separate battery for eachPower/Combo Cabinet). This will ensurethe highest level of adaptability for anycritical installation and/or economicaldriving factors.

TURNKEY SOLUTIONSUser may deploy Multi Power cabinetslining up four Cabinets one to each otherand arranging locally for input and outputcabling.The UPS offers as an alternative a 500 kVAturn-key solution which consist in twoPower Cabinets (MPW300 PWC)and aSwitching Cabinet to tie up the two. Itincludes AC input/output terminals forsite power distribution connection, relatedjoining flexible bars and communicationlinks between Power Cabinets andSwitching Cabinet. Switching Cabinet isalso supplied with AC input/output/bypasslines breakers as well as with an integralwrap around maintenance bypass. Bypass

line is protected with fuses to grant faultdiscrimination and load protection in caseof short circuit downstream.The breaker set enable to galvanicallyinsulate the single Power Cabinets and tocarry out specific maintenance.Switching Cabinet cable entry is arrangedso that user may decide either to accessfrom the bottom front, rear side or top.This on hand solution simplify theinstallation activity and contribute to theoverall TCOreduction minimising, upfront,installation and operating costs.

ADVANCEDCOMMUNICATIONSUsers can benefit from the differentcommunication systems developedspecifically for IT personnel, facilitiesmanagers and service engineers.The 7” LCD touch screen, communicationslots, relay cards along with the dedicatedservice ports, all ensure that the UPSsetup, control and monitoring is easy.The Multi Power LCDtouch screen hasembedded the follow protocols:• UDP to communicate with our shutdownsoftware PowerShield3

• HTTPand HTTPSto monitor the UPSstatus using a standard web browserwithout any additional software.

• SMTPto send emails related to the UPSstatus, alarms and a power quality dailyand weekly report.

In addition, with the network card NetMan204, Multi Power can be integrated intoany building management system anddata centre infrastructure (CDIM)with theprotocols:• SNMP v1,v2 and v3.• Modbus/TCP.Multi Power is compatible with the verylatest operating systems including• Windows 7, 8, 10• Hyper-V• Windows Server 2019, 2016, 2012,andprevious versions

• Mac OS X• Linux• VMWare ESXi• Citrix XenServerPlus many other Unix operating systems.

Power Cabinet MPX130 PWC(1-5 x MPX 15PM or MPX 25 PM).

25 50 75 100 P (kW) %

100

80

60

40

20

%S 0

20

40

60

80

100

Q (kVAR) %

Q (kVAr) %

CAPACITIVE

INDUCTIVE

cosfi 0.9100% kVA

cosfi 1100% kVA=kW

cosfi 0.9100% kVA

Battery Cabinet (MPW 170BTC)with openand closed door.

Page 5: SIEL DATMPWM3P20CREN Brochure

DETAILS

BYPASS MODULE(BM)

MPW 300 PWC

MPW Power Cabinet42-294 kW(front)

CONNECTIVITYPANEL (CP)

MANUAL BYPASSSWITCH (SWMB)

POWER MODULE(PM)

MPW 300 PWC

MPW Power Cabinet42-294 kW

(rear)

RELAY SLOT

AUXILIARYSIGNALBOARD (ASB)

MONITORINGUNIT (MU)

POWERSUPPLY UNIT

(PSU)

BATTERY UNIT(BU)

BATTERYSWITCH

(SWBATT)

MPW 170 BTC

MPW Battery Cabinet(front)

MPX 130 PWC

MPX Power Cabinet15-75 kW or 25-125 kW

(front)

MPX 130 PWC

MPX Power Cabinet15-75 kW or 25-125 kW

(rear)

MONITORINGUNIT (MU)

POWERSUPPLY UNIT

(PSU)

BATTERY UNIT(BU)

BATTERYSWITCH

(SWBATT)

MPW 170 BTC

MPW Battery Cabinet(front)

RELAYSLOT

AUXILIARYSIGNALBOARD (ASB)

CONNECTIVITYPANEL (CP)

MANUALBYPASS SWITCH(SWMB)BYPASS

MODULE(BM)

POWERMODULE (PM)

Page 6: SIEL DATMPWM3P20CREN Brochure

DETAILS

MPW 130 CBC

MPW Combo Cabinet42-126 kW(front)

MPW 130 CBC

MPW Combo Cabinet42-126 kW

(rear)

CONNECTIVITYPANEL (CP)

BYPASS MODULE(BM)

MANUAL BYPASSSWITCH (SWMB)

POWER MODULE(PM)

BATTERY UNIT(BU)

BATTERYSWITCH(SWBATT)

RELAYSLOT

AUXILIARYSIGNALBOARD (ASB)

MONITORINGUNIT (MU)

POWER SUPPLYUNIT (PSU)

BATTERY UNIT(BU)

BATTERYSWITCH

(SWBATT)

MPW 170 BTC

MPW Battery Cabinet(front)

MPX 100 CBC

MPX Combo Cabinet15-60 kW or 25-100 kW

(front)

MPX 100 CBC

MPX Combo Cabinet15-60 kW or 25-100 kW

(rear)

POWER MODULE(PM)

CONNECTIVITYPANEL (CP)

MANUALBYPASSSWITCH(SWMB)

BYPASS MODULE(BM)

BATTERYSWITCH

(SWBATT)BATTERY UNIT(BU)

RELAYSLOT

AUXILIARYSIGNALBOARD (ASB)

MONITORINGUNIT (MU)

POWER SUPPLYUNIT (PSU)

BATTERY UNIT(BU)

BATTERYSWITCH

(SWBATT)

MPW 170 BTC

MPW Battery Cabinet(front)

Page 7: SIEL DATMPWM3P20CREN Brochure

DETAILS

CONNECTIVITY PANEL (CP)10/100 NETWORK

POWER SUPPLYUNIT (PSU)

MAINCOMMUNICATIONUNIT (MCU)MONITORINGUNIT (MU)

COMMUNICATIONSLOTS

AUXILIARY SIGNAL BOARD (ASB)

SWINSWMBSWBYPSWBATTSWOUTTEMP

OPENINGRELEASESWBATT

R.E.P.O.

AUXEXTCONTACTS

MPW Switching Cabinet 500+ 2 x MPW 300 PWC(front without doors)

MPW Switching Cabinet 500+ 2 x MPW 300 PWC(rear without panels)

SWIN ASWIN B

SWOUT ASWOUT B

SWBY ASWBYB

SWMB

MPW 300 PWC A MPW 300 PWC B

MPW 300 PWC A MPW 300 PWC B

Note:1)On MPX 130 PWCconnectivity panellayout is different.2) Second PSU on MPX130PWC is optional.

Page 8: SIEL DATMPWM3P20CREN Brochure

MODELS MPW BATTERYCABINET - MPW 170 BTC(MODULAR BATTERY CABINET)

BB2000 480-V6 / BB2000 480-V7BB2000 480-V8 / BB2000 480-V9

AB2000 480-V9(CONVENTIONAL BATTERY CABINET)

UPS MODELS Select the Battery configuration according Multi Power range

Dimensions[mm]

2000

600 1050

Modular BC

2000

860800

BB

BATTERYCABINETS

OPTIONS

SOFTWAREPowerShield3

PowerNetGuard

ACCESSORIESNETMAN 204MULTICOM 302MULTICOM 352MULTICOM 372MULTICOM 384MULTICOM 411

MULTI I/OMULTIPANEL

PRODUCT ACCESSORIESBattery temperature sensorOn front door air filterIP21Protection KitProgrammable relay boardMULTICOM 392Switching CabinetCold Start

Page 9: SIEL DATMPWM3P20CREN Brochure

1 Including Redundancy2 For wider tolerance conditions apply.3 PM = Power Module (either referring to MPX15PM,MPX25 PM orMPW 42 PM)

4 BU = Battery Unit

NOTE:All performances quoted in a single row refer to any UPSsystem configuration from one to seven modules running inparallel unless specified differently.

MODEL Multi Power - from 15 to 294 kW1

INPUTRated voltage [V] 380 / 400 / 415three-phase plus neutralRated frequency [Hz] 50 / 60Voltage tolerance [V] 400 ±20% @ full load2

Frequency tolerance [Hz] 40 - 72Power factor 1THDI <3%

BYPASSNominal power [kW] 252 / 126(According to system power configuration)Rated voltage [V] 380 / 400 / 415three-phase plus neutralVoltage tolerance [V] from 180 (adjustable 180-200) to 264 (adjustable 250-264) referring to NeutralRated frequency [Hz] 50 or 60Frequency tolerance [Hz] ±5% (selectable)Overload 125%for 10min.; 150% for 1min.

BATTERIES Modular Type (MPW 170 BTC) Conventional TypeLayout Modular type made up by Battery Unit (named BU) Free Standing Battery cabinet / Shelf

Battery featuresVRLAbatteries lined up inside BU;

Constant voltage and current measuring at BU level;Battery status monitoring via Multi Power LCDdisplay

Conventional battery Blocks VRLAType

Cabinet lay out description 9 x Battery shelves 1x (20 + 20) BlocksDimensions (WxDxH) [mm] 600x1050x2000 860x800x2000Weight [kg] (without PM3/BU4) 280 250

OUTPUTRated voltage [V] 3802 / 400 / 415three-phase plus neutral

Rated frequency [Hz] 50 or 60

Voltage stability ±0.5%

Dynamic stability EN62040-3 class performance 1non linear load

OVERALL SPECIFICATIONS

Cabinet type MPX 130 PWCPower Cabinet

MPW 300 PWCPower Cabinet

MPX 100 CBCCombo Cabinet

MPW 130 CBCCombo Cabinet

Power Module nominalpower [kW] (Named PM) MPX 15PM / MPX 25 PM MPW 42 PM MPX 15PM / MPX 25 PM MPW 42 PM

Solution nominal Power [kW] 75 / 125 294 60 / 100 126

Output power factor [pf] 1 1 1 1

Parallelable (up to) 4 4 4 4

Cabinet layout description 5 x MPX 15 PM5 x MPX 25 PM 7 x MPW 42 PM

4 x MPX 15 PM4 x MPX 25 PM

+ 6 x Battery shelves3 x MPW 42 PM

5 x Battery shelves

Dimensions [WxDxH] 600x1050x1200 600x1050x2000 600x1050x2000 600x1050x2000

Weight [kg] (without PM3/BU4) 145 300 350 340System Noise Level at 1m[dBA±2] <65 <68 <64 <64

ECOMode Efficiency Up to 99%

Cabinet IP rating IP20 finger proof (either with cabinet doors open or close)

Cable input Rear side either top or bottom

Colour RAL 9005Ambient temperaturefor the UPS 0 °C - +40 °C

Recommendedtemperature for battery life +20 °C - +25 °C

Rangeof relative humidity 5-95% non-condensing

Altitude [m] 6000 max altitude

StandardsEuropean directives: L V 2014/35/EU low voltage Directive EMC2014/30/EUelectromagnetic compatibility

Directive Standards: Safety IECEN 62040-1; EMC IECEN 62040-2 - category C2; RoHS compliantClassification in accordance with IEC62040-3 (Voltage frequency Indioendent) VFI - SS - 111

Moving UPScabinet types Castors (any cabinet type is shipped without PM and BU)

Page 10: SIEL DATMPWM3P20CREN Brochure

2

5

1

3

4

MULTI POWER EMBEDDED PROTOCOLS

1 MPW / MPX

2 Web Browser

3 PowerShield3

4 Mail Server

5 Ethernet SwitchEthernet

4

5

1

3

MULTI POWER PROTOCOLSADDING NETMAN 204 CARD

1 MPW / MPX

2 NetMan 204 board

3 Modbus/TCP Manager

4 SNMPManager

5 Ethernet SwitchEthernet

2

Modbus/TCP Protocol

SNMPProtocol

DAT

MPWM3P

20CREN

SIEL Energy Systems LtdSIEL House, Unit E, Draycott Business Park, Cam, Glos. GL11 5DQtelephone: 0845 1306118. email:[email protected] www.sielenergy.co.uk

POWER PROTECTION SOLUTIONSFor mission critical applications & essential services

Theinform

ationinthisdo

cumen

tissubjecttochan

gewithou

tno

tice.SIEL

Energy

System

sLtdassumesno

respon

sibilityfora

nyerrorsthat

may

appe

arinthisdo

cumen

t.