24
WiFi-enabled Vibration and Impact Monitoring System

Shockwatch OpsWatch Presentation

Embed Size (px)

Citation preview

WiFi-enabled Vibration and Impact Monitoring System

Owner
Text Box
Owner
Typewritten Text
Your Local Agent!
Owner
Typewritten Text
D B Services! 512-423-8360 [email protected]
Owner
Typewritten Text
Diamond B Services 512- 423-8360 [email protected]

Key Benefits of OpsWatch

Dual Mode Monitoring

■ Dual Configuration Profiles (Transport & In-Line Monitoring)

■ Ability To Switch From Battery To External Power Source

Rugged Design For Tough Conditions

■ EX/ATEX Certifications

■ IP67 Rating For Dust/Liquid Immersion

■ Durable Material Composition To Stand Up To Rough Handling

■ Wide Temperature Operating Range

Simplified Data Management

■ Self contained unit with built in intelligence vs. sensors reporting all data to a

centralized software gateway

■ Turnkey product that easily streams via Wi-fi (versus mesh / Bluetooth alternatives).

Superior Monitoring Capabilities

■ Trusted and patented ShockWatch accelerometers and algorithms.

■ Both Shock & Vibration Monitoring

■ Proprietary accelerometer detects lower signals than MEMS

Oil and Gas – OpsWatch Application

Generators■ Power source for rig

Mud Pumps■ Reciprocating equipment

used to circulate drilling fluids

Top Drive■ Rotating equipment the

turns the drill stream

Draw-works■ Primary hoisting machinery

(AC/DC motors, etc.)

Drilling Rig Components

Must be ATEX on Off-Shore Rigs

Key Development Requirements

Dual Mode Functionality – Both Transport and Condition Based

Monitoring (CBM)

Streaming Data – Communicate Precision Shock & Vibration Data

Through WiFi Connectivity

EX/ATEX Approved Version – spark proof or intrinsically safe for,

Zone 1, environments (i.e. chemical / oil & gas)

ATEX, CSA, EX, Intrinsically Safe

What Does It All Mean?

Intrinsically safe is used to describe products that

are destined for an explosive area.

■ It is a protection concept that is based around limiting the

available electrical energy to nonincendive levels (i.e.,

sparks cannot occur from short circuit or failures that

could cause an explosive atmosphere to ignite).

■ Products bearing marks have been tested to meet certain

standards & production sites have been audited to meet

certain compliance measures.

Certification Marks

■ United States & Canadian Safety Standards

■ United Kingdom & Europe Safety Standard

Covered by the ATEX Directive

Application Example

Hot Gas Defrost Refrigeration Systems

Food & Beverage manufacturing requires the use of complex refrigeration.

Pressures and temperatures inside evaporator piping will vary significantly

from one phase of defrost to the next.

Under these changing conditions pressure shocks can occur, causing

gradual or sudden damage to components and piping.

Questions?

0

0.25

0.5

0.75

1

1.25

1.5

1.75

2

2.25

2.5

2.75

3

Z axis

Acce

lera

tio

n (

G)

Time

Server restart validation check

Installation finalization Generator online

Generator start

Startup - Drill Site Generator

FFT PSD

Generator

not running

Generator

running

FFT

PSD

-0.8

-0.6

-0.4

-0.2

0

0.2

0.4

0.6

0.8

1

1.2

0 0.2 0.4 0.6 0.8 1 1.2

Data Streaming - 1 second

X Y Z

Time (secs)

Acce

lera

tion (G

)